Home
ST200 Smart Table Manual
Contents
1. Please obtain RA prior to return of item Company Please obtain RA prior to return of item Address Date Country Phone Number P O Number FAX Number Item s Being Returned Model Serial Description Reason for return of goods please list any specific problems Newport Corporation Worldwide Headquarters 1791 Deere Avenue Irvine CA 92606 In U S 800 222 6440 Tel 949 863 3144 Fax 949 253 1680 Internet sales newport com Newport Visit Newport Online at www newport com
2. Software Application Overview Provided on the CD that comes with the Smart Table Controller is an installation package for SmartTable Util application and USB drivers This application communicates with the Smart Table Controller through USB communication interface The application is designed to allow the user to remotely control all the features supported by the controller R Figure 17 Smart Table Util Software Icon NOTE Install the software and USB drivers before connecting USB cable to the controller for the first time 1 Minimum requirements for the computer are A personal computer with a 486DX or higher processor Microsoft Windows 98 operating system or Microsoft Windows 2000 XP operating system 64 MB of memory for Windows 10 MB of hard disk space USB port version 1 1 minimum VGA or higher resolution video adapter Microsoft Mouse or compatible pointing device CD ROM drive for installation only 1 Place the CD that accompanies the controller in your CD ROM drive Installation of the SmartTable Util application and USB drivers will start automatically If it does not start initiate installation by double clicking on the SETUP EXE file in the CD 25 26 5 1 1 Smart Table Utility Function Tabs Mouse over some buttons will reveal Tool Tips for ease of use Software Application 2 Connect the USB cable to the Controller and Power it on 3 Start the application by double clicking on
3. Auto Tune button Clicking on the Auto Tune button here is similar to pushing Auto Tune button on the controller s front panel with added control over the control loop gain stability margin The controller uses medium stability setting when auto tuning process 1s started locally Clicking on Enable Damping or Disable Damping buttons te will enable or disable damping If the damping is enabled the Disable Damping button is visible and vice versa Click on Measure Un damped Vibration Level button to record vibration level with damping disabled The software will disable damping on both channels and measure vibration levels over a period of 500ms The data will be averaged over several time frames Number of averages can be set on the Options tab Section 5 1 5 2 Click on Measure Damped Vibration Level button to record vibration level with damping enabled The software will enable damping on both channels and measure vibration levels over a period of 500ms The data will be averaged over several time frames Number of averages can be set on the Options tab Section 5 1 5 2 Both un damped and damped vibration level data can be displayed in either frequency domain or time domain Select either FFT or Time Resp from the pull down menu for desired view The FFT resolution is 2 Hz The software also provides access to viewing the measurements for only one channel or both chan
4. Atto T hi ennn e 23 Alo USB UG 21 oirein aA TO 23 42 RE Pane ieuan na r E O E E A a 24 4 2 1 Damper Output connectors cc ceeeeeccceeeeeeeeceeeaeeees 24 4 2 2 Frame or Chassis Terminal ccc cece ccceeecccceeeecceeeeeeees 24 Ao AC Power Inlet SOCK Class Scouser teacnesecsbustaharsastinsareien eae 24 5 Software Application 25 Di HOV ET VAC Wc tactics EE 25 SEL Aboue aD ata irradi dei cea ea era 26 3A Sa aD wares adia tds ahaa nada adie hcat uae nadaiee 27 SE AUTOS TONS TaD ea 28 SA Manual Tone TaD recare a E 30 SLS ODPHONS TaD nsara sertinccnen te nds Welsitedesaediaened 31 6 Maintenance and Service 33 Ol Enclose Crainn essene E 33 G2 FUSE RENICE eree ie E E NEES 33 6 3 SODEAININ 8 SEIN CC enoni E O dosueetoantionkoseses 34 GF MM E E 6 E EEN E O ES E EA E E EN Cor Re 35 List of Figures Figure 1 General Warning or Caution Symbol ccccseseccecceeeeeeeeeeeeeaaees 9 Figure 2 Electrical Shock Symbol cccccccccccccccsssssnsssesesceeeeeeeeeeccceeeetaneeas 9 Figure 3 CSA mark with C and US Indicators cc ccccccceceseeseeeeeeeeees 9 Figure 4 OT INNA e ets tueateaata Masoestaiatadiea E E A A 10 Figure 5 Fuse SyYmMmDOl Bprmpere erates metartn tite a Oenrerintrate ere tana 10 Figure 6 Frame or Chassis Terminal Symbol ccccccceeeeeeeeeeeeeeeeeaees 10 Figure 7 On SVM DO laoret oaea a a enS 10 Figure 8 OI Sybo eres er em ter ee renee eee eee 11 Figure 9 Pro
5. 1 1 3 CSA Mark with C and US Indicators ee 9 Lila European Union CE MarK sss 5 0id cinco n eTe 10 LLS TAUSES erener E R E 10 l hO Frame or NaSS iS da a A TN 10 LA Oesman a a 10 kS Oaa E N E 11 1 1 9 Protective Conductor Terminal ccccceseeceeeeceeeeeees 11 DUO USB Connector Symboler a oacetaonacenes 11 1 1 11 Mounting precaution 0 ccccccessssessesseeeceeeeeeeeeeeeeaaaaas 11 k2 Warnns andC aulions eset g rete o e a a 12 1 21 General W arnin OS acnrccccciesereninierisao n anaoriasanerniaaa 12 W222 General aUos 2a ken talacn ese eel tee eee anaes 13 1 3 Location Of Warnings cccccccccccccccececeeeceeeeeeceeeeeeeeeeeeeeeeeeeeeeees 13 Eor Ao fal EIN eee ge er ee Pee or ne 13 2 _ General Information _ _ _ _ _ _ ___ _ B Dv TOUCH Oikein N 15 2 SPECICAONS iseni ee E E emesis 16 3 Getting Started YD Je Unpacknoand Handie srera a 19 32 Tnspection for Damate eensiireerree A AN 19 Bao PASES a E cent atetehahetnad tae menrateedneteta 19 3 4 Choosing and Preparing a Suitable Work Surface 20 35 Electrical ReguiremeniS sein saves syiutatacsasesienaues touted cunanedeeiavess 20 SiG POWT SUPDG Sonra D 20 3 7 Operatin Temper orrn a wadiieeanwewaes 20 Preface vil 4 System Operation 21 AM OTE ANN Ch atau ditssyiissh Sicucrsh tarda duloc bhp alah ald bibiasbotisawcbhxdatulont Sunde easisee 21 ALL PC POW CE SWC eeir ERREA 21 LE ANIS a 22 Po T Oea E AAT 22 4 kA
6. dissipation to all natural vibration modes of the table in a wide frequency range without creating any additional resonances at lower frequencies If the load on the table changes the dampers maintain their efficiency and stability after simple auto tuning of control gains 15 16 General Information 2 2 Specifications Wandne Sure 400 Series ferromagnetic stainless steel g 3 16 in 4 8 mm thick with integrated damping layer pace nee 0 004 40 1 over 2 ft 600 mm square in mm Trussed honeycomb vertically bonded closed cell construction Core Design 0 010 in 0 25 mm Steel sheet materials 0 030 in 0 76 mm Triple core interface Active Damping Adjustable electronic dampers Siructurai Deni Constrained layer core damped working surface and PING composite edge finish 1 4 20 holes on 1 in grid M6 1 0 holes on 25 mm grid 0 5 in Hei e eles borders 12 5 mm borders Easy clean conical cup 0 75 in 19 mm deep glee OE EANG Non corrosive high impact polymer material Table 1 Specifications Compliance in Ib damped corner 1 10 1 10 5 hs 4 1 10 T ha z Th i cut 1 10 k i u i 4 z 1 10 3 10 100 1 10 Hz OFF Figure 12 Typical Compliance Curve This data was taken on a ST 48 8 table supported by I 2000
7. isolators Displacement nm General Information 17 Vibration linear spectrum 25 cm from edges near an instrumented corner 0 y TE 50 100 150 200 250 300 350 400 450 Frequency Hz Damping ON Damping OFF Figure 13 Effect of damping on table vibration levels The Smart Table uses the same materials and has the same main mechanical characeristics as passively damped Newport RS series table The dampers are installed at two corners of the table adjacent to a long side The exact position of each damper is indicated by three flat head screws that are flash with the table top at the corners CAUTION Please keep in mind that four sealed threaded holes in each damper area are only 0 457 in 11 6 mm deep If you need to use some of these holes choose the length of the screws accordingly An attempt to use too long screws may cause damage to the dampers and de lamination of the table face sheet 18 General Information Smart Table Controller Specifications Output Power anes Continuous current 0 4A 12VDC Output Voltage ace Maximum effective output voltage at continuous power 12V 0 4A Input Power Voltage 12V 5 Average Current continuous output rating 0 6A Peak Current continuous output rating 0 7A Table 2 Smart Table Controller Specifications System Environmental Specifications AC Input 100 240VAC 10 47 63Hz 1 25A 80W Operating Temperature 5 C to 40
8. the newly created Smart Table Util icon in Start gt Programs gt Newport gt Smart Table Controller folder The SmartTable Util application has five 5 main tabs About Status Auto tune Manual Tune and Options The features available in these tabs are explained in the following sub sections About Tab When the application is opened it will default to the About tab It will also start communication with the controller connected to USB interface The application and controller firmware version numbers are displayed on this screen Gal SmartTable Util CS Newport SMART TABLE CONTROLLER ST 200 Status Auto tune anual Tune Options About Software and Firmware Versions Sotware Version 2 00 Firmware Version 2 00 SmartTable Controller Bottom Bar is common to all the screens al USB Communicatyn ACTIVE USB Address 1 Controller S H 1 1222004 04 25 34 PO Figure 18 About Tab Screen Click on Firmware Download button to update the controller s firmware The software will prompt the user to select a DSP Firmware File at the beginning of the firmware download process This file has an FWR extension and is located in the Firmware subdirectory by default Once this file is selected the application will initiate the download process This process consists of the following steps Erase Firmware At this stage the controller s existing firmware is erased fro
9. to the Newport Programs and Related Materials These restrictions shall not apply to information 1 generally known to the public or obtainable from public sources 2 readily apparent from the keyboard operations visual display or output reports of the Programs 3 previously in the possession of Customer or subsequently developed or acquired without reliance on the Newport Programs or 4 approved by Newport for release without restriction Service Information This section contains information regarding factory service for the source The user should not attempt any maintenance or service of the system or optional equipment beyond the procedures outlined in this manual Any problem that cannot be resolved should be referred to Newport Corporation Preface V Technical Support Contacts North America amp Asia Europe Newport Corporation Service Dept Newport MICRO CONTROLE S A 1791 Deere Ave Irvine CA 92606 Zone Industrielle Telephone 949 253 1694 45340 Beaune la Rolande FRANCE Telephone 800 222 6440 x31694 Telephone 33 02 38 40 51 56 Newport Corporation Calling Procedure If there are any defects in material or workmanship or a failure to meet specifications promptly notify Newport s Returns Department by calling 1 800 222 6440 or by visiting our website at www newport com returns within the warranty period to obtain a Return Material Authorization Number RMA Return the product to Newport Corporation freight prep
10. 34 6 3 Maintenance and Service Figure 24 Fuse Replacement WARNING To reduce the risk of electric shock or damage to the instrument turn the power switch off and disconnect the power cord before replacing a fuse If a fuse blows 1 Disconnect the power cord from the controller 2 Pry out the fuse cover and remove the fuse holders 3 Replace the fuse s Use only 5 20mm time lag fuses as indicated below Fuse Replacement 1 25Amp T 250V 4 Reconnect the power cord and turn on the instrument 5 Ifthe problem persists contact Newport Corporation for service Obtaining Service The Smart Table Controller contains no user serviceable parts To obtain information regarding factory service contact Newport Corporation or your Newport representative Please have the following information available 1 Instrument model number on the rear panel 2 Instrument serial number on rear panel 3 Description of the problem If the instrument is to be returned to Newport Corporation you will be given a Return Number which you should reference in your shipping documents Please fill out a copy of the service form located on the following page and have the information ready when contacting Newport Corporation Return the completed service form with the instrument Maintenance and Service 6 4 Service Form CYS Newport Corporation U S A Office 800 222 6440 FAX 949 253 1479 Newport Name Return Authorization
11. C Operating Humidity lt 85 relative humidity non condensing Storage Temperature 0 60 C RH lt 85 non condensing Altitude Electrical Class Pollution Degree Use Location Indoor use only Table 3 Envoronmental Specifications 3 1 3 2 3 3 Getting Started Unpacking and Handling It is recommended that the Smart Table Controller is unpacked in a lab environment or work site Unpack the system carefully small parts and cables are included with the instrument Inspect the box carefully for loose parts before disposing of the packaging You are urged to save the packaging material in case you need to ship your equipment in the future Inspection for Damage The Smart Table Controller is carefully packaged at the factory to minimize the possibility of damage during shipping Inspect the box for external signs of damage or mishandling Inspect the contents for damage If there is visible damage to the instrument upon receipt inform the shipping company and Newport Corporation immediately WARNING Do not attempt to operate this equipment if there is evidence of shipping damage or you suspect the unit is damaged Damaged equipment may present additional hazards to you Contact Newport technical support for advice before attempting to plug in and operate damaged equipment Parts List The following 1s a list of parts included with the Smart Table System ST Series table with dampers already installed inside
12. STEM CH1 and CH2 status LED s 4 1 3 I O The vibration can be monitored independently by connecting signal processing equipment such as a signal analyzer or an oscilloscope to the BNC jacks on the front panel of the controller The measurement parameters are listed in Table 5 below Measurement parameters Sensitivity 30 V mm s 12 Measurement range 0 p 0 16 mm s Frequency range 3 dB 18 Hz to 820 Hz Table 5 Measurment Parameters 4 1 4 4 1 5 System Operation 23 BNC sensitivity 100 Sensitivity V mm s l 10 100 1 10 Frequency Hz Figure 15 BNC output sensitivity Auto Tune The auto tune button allows the user to retune the system The auto tuning process takes normally 30 to 40 seconds Care must be taken not to disturb the table during this time If there 1s equipment on the table that can be a source of non stationary vibration or noise it should be shut down If the table was inadvertently disturbed by mechanical shock or loud noise during the auto tuning it is recommended to repeat the process Beeping or tonal sounds can be heard from the dampers during the auto tuning process Please have in mind that during the auto tuning process the table may experience higher vibrations that during the normal operation The controller comes pre set for the optimal performance of the lightly loaded
13. Smart Table ST 200 SmartTable Controller i S Spectra Physics Wiska of Kenwport Corpor User s Manual Newvport Experience Solutions EU Declaration of Conformity We declare that the accompanying product identified with the CE mark complies with requirements of the Electromagnetic Compatibility Directive 2004 108 EC and the Low Voltage Directive 2006 95 EC Model Number Model ST 200 Smart Table Controller Year C mark affixed 2004 Type of Equipment Electrical equipment for measurement control and laboratory use Manufacturer Newport Corporation 1791 Deere Avenue Irvine CA 92606 Standards Applied Compliance was demonstrated to the following standards to the extent applicable BS EN61326 1 2006 Electrical equipment for measurement control and laboratory use EMC requirements This equipment meets the CISPR 11 2006 Class A Group 1 radiated and conducted emission limits IEC 61010 1 2001 second edition Safety requirements for electrical equipment for measurement control and laboratory use James Fisher Group Director Vibration Control Newport Corporation 1791 Deere Ave Irvine CA 92606 USA Preface lil Warranty Newport Corporation warrants that this product will be free from defects in material and workmanship and will comply with Newport s published specifications at the time of sale for a period of one year from date of shipment If found
14. W Electrical Hazard MAX Power Figure 11 Locations of warnings on the rear panel 14 Safety Precautions This page is intentionally left blank 2 1 General Information Introduction The Smart Table 1s a combination of the structurally damped vibration isolation table with electronics that can monitor vibration in real time and active elements that use the vibration data to suppress the vibration Vibration state of the optical table is an important characteristic in many cases defining its suitability for a task at hand Reducing vibration especially the dynamic deviation of the table from a rigid body type behavior 1s one of the most important criterions of the table design It is achieved mainly by the vibration isolation Vibration isolation by passive isolating legs such as Newport I 2000 reduces the vibration transmitted to the table from the floor Although excellent isolation from floor vibration can be achieved in these systems the table will deviate from the ideal rigid body behavior at natural frequencies of its flexural vibrations External sources acting on the tabletop air turbulence or acoustical waves or the dynamic events generated in the payload excite resonance vibration in the table s own free state modes such as bending and torsion This can lead to deterioration of the payload performance in particular misalignment of the optical equipment The Smart Table includes two active vibration dampers that add
15. aid clearly marked with the RMA and we will either repair or replace it at our discretion Newport is not responsible for damage occurring in transit and is not obligated to accept products returned without an RMA E mail rma service newport com When calling Newport Corporation please provide the customer care representative with the following information Your Contact Information Serial number or original order number Description of problem 1 e hardware or software To help our Technical Support Representatives diagnose your problem please note the following conditions Is the system used for manufacturing or research and development What was the state of the system right before the problem Have you seen this problem before If so how often Can the system continue to operate with this problem Or is the system non operational Can you identify anything that was different before this problem occurred Preface Table of Contents EU Declaration OF Contorni aier a ll Warranty euena nabs utd chaccan nie dellib uber laine Cu lul as il Technical Support Contacts 0 cccccccccccccccssssssessseseeeeceececeeeeeeeeeeeaaaaas V PADIS OL GC ONUCINS re E E O vi DASE OPE 16 TCS camen a A AE ATEEN vii List of Tables isinen E vili 1 Safety Precautions 9 kl Denimtnons and SymDOls pie a E ee 9 1 1 1 General Warning or Caution ccccccccccccceeeeeeeeeeeeeeeeees 9 kk PIECH SHOCK stasis Gicenscead E 9
16. as 18 Definition of SYSTEM CH1 and CH2 status LED s 22 Measurment Parameters cccccecececcecececcccccccccecscccccsesceccucceces 22 1 1 1 1 1 1 1 2 1 1 3 Safety Precautions Definitions and Symbols The following terms and symbols are used in this documentation and also appear on the Smart Table Controller where safety related issues occur General Warning or Caution Figure I General Warning or Caution Symbol The Exclamation Symbol in the figure above appears in Warning and Caution tables throughout this document This symbol designates an area where personal injury or damage to the equipment is possible Electric Shock Figure 2 Electrical Shock Symbol The Electrical Shock Symbol in the figure above appears throughout this manual This symbol indicates a hazard arising from dangerous voltage Any mishandling could result in irreparable damage to the equipment and personal injury or death CSA Mark with C and US Indicators Figure 3 CSA mark with C and US Indicators The presence of the CSA mark with C and US indicates that it has been designed tested and certified as complying with all applicable U S and Canadian safety standards 10 Safety Precautions European Union CE Mark CE Figure4 CE Mark The presence of the CE Mark on Newport Corporation equipment means that it has been designed tested and certified as complying with all a
17. d fuse s with the correct type number voltage and current ratings as referenced in the appropriate locations in the service instructions or on the equipment Only qualified service personnel should replace fuses e To avoid explosion do not operate this equipment in an explosive atmosphere Qualified service personnel should perform safety checks after any service Safety Precautions 13 1 2 2 General Cautions Observe these cautions when operating or servicing this equipment e If this equipment is used in a manner not specified in this manual the protection provided by this equipment may be impaired e To prevent damage to equipment when replacing fuses locate and correct the problem that caused the fuse to blow before re applying power e Do not block ventilation openings e Use only the specified replacement parts e Follow precautions for static sensitive devices when handling this equipment e This product should only be powered as described in the manual There are no user serviceable parts inside the ST 200 Smart Table Controller e To prevent damage to the equipment read the instructions in the equipment manual for proper input voltage 1 3 Location of Warnings 1 3 1 Rear Panel Frame or Chassis Terminal Fuse info r DAMPERS _4 CH2 CHI 1 8 15 CAUTION DO NOT REMOVE COVER REFER SERVICING 10 GUALIRED 100 240V 47 631 PERSONNEL INECT INPUT POWER BEFORE REPLACING FUSE MAX POWER SO
18. ds of time Miscellaneous Click on Apply Settings button in order for the application to send any changes made on this tab to the controller Click on Save Settings to File button to save the controller s settings to a file on user s PC Click on Restore Settings from File button to restore the controller s settings from a file on user s PC Click on Restore Default Settings button to restore the controller s settings to default values Figure 23 Options Tab Screen 6 Maintenance and Service CAUTION There are no user serviceable parts inside the Smart Table Controller Work performed by persons not authorized by Newport Corporation will void the warranty 6 1 Enclosure Cleaning WARNING Before cleaning the enclosure of the Smart Table Controller the AC power cord must be disconnected from the wall socket The enclosure may be cleaned with a soft cloth dampened with either a mild soapy water solution or Isopropyl Alcohol Do not use any other chemicals or solutions Danger Flammable cleaning liquid avoid sources of ignition and clean in well ventilated area 6 2 Fuse Replacement NEWPORT MODEL NO ST 200 amp Pry open cover to EECA UA aS remove fuses r DAMPERS 4 CH2 CHI 1 8 15 CAMON DO NOT REMOVE COVER REFER SERVICING 10 QUALIRED m 100 240 47 63He PERSONNEL DISCONNECT INPUT POWER BEFORE REPLAONG FUSE MAX POWER 80W 33
19. g side The exact position of each damper is indicated by three flat head screws visible flash with the table top Please have in mind that four sealed holes in each damper area are only 0 457 in 11 6 mm deep If you need to use some of these holes choose the length of the screws accordingly An attempt to use too long screws may cause damage to the dampers and de lamination of the table face sheet Safety Precautions 1 2 Warnings and Cautions The following are definitions of the Warnings Cautions and Notes that are used throughout this manual to call your attention to important information regarding your safety the safety and preservation of your equipment or an important tip WARNING Situation has the potential to cause bodily harm or death CAUTION Situation has the potential to cause damage to property or equipment NOTE Additional information the user or operator should consider 1 2 1 General Warnings Observe these general warnings when operating or servicing this equipment Heed all warnings on the unit and in the operating instructions Do not use this equipment in or near water This equipment is grounded through the grounding conductor of the power cord Route power cords and other cables so they are not likely to be damaged e Disconnect power before cleaning the equipment Do not use liquid or aerosol cleaners use only a damp lint free cloth e To avoid fire hazard use only the specifie
20. h Freq Hz o MARNE te T all MATAA RTA LLERA ER Ah a ART i eapo a0 ya aa a o Ta T ME BSB S a DAMPING ENABLED all aan 1 1 1 1 i 1 1 1 1 0 00 0 05 0 10 0 15 0 20 0 25 0 30 0 35 0 40 O45 0 50 MV Show Graph Time sec Apply asure Undampec ur ip Damped 5 Changes Rare ET a FF Figure 22 Manual Tune Tab Screen Amplitude microns Nm D o o D 9 1 5 5 1 5 1 5 1 5 2 5 1 5 3 Software Application NOTE Apply Changes button needs to be pushed every time the settings are changed so that the changes can be sent to the controller After examining the damped vs un damped vibration levels 1f the users find some undesirable amplified resonance peak that peak can be reduced by enabling the optional notch filter Check the Enable Notch Filter box specify the desired frequency and click on Apply Changes button Note that selecting this option can destabilize the controller depending upon the notch frequency Click the Disable damping button and reverse the erroneous changes to return to stable work Options Tab The Options Tab allows the user to customize the controller and the SmartTable Util functionality to their requirement It provides access to the following Auto tuning e Enable the front panel switch Uncheck this box to disable initiation of auto tuning process locally Low Medium and High control loop gain margins Specify the desired percentage by which control loo
21. m its non volatile flash memory 9 1 2 Software Application e Download New Firmware If the firmware erase was successful the software will download the selected firmware to the controller Reset Controller Ifthe firmware download was successful the software will perform a soft reset of the controller in order for the newly downloaded firmware to take affect Ensure that USB communication is not lost between the controller and PC due to power outage unplugged USB cable during the firmware download process Status Tab A few seconds after the About screen appears the application will switch to the Status Tab NORMAL DAMPER NOT CONNECTED DAMPER NOT CONNECTED NWO ERROR DETECTED aa Ee soon Figure 19 Status Tab Screen This tab provides the current status of the controller The status of System Channel 1 and Channel 2 LEDs shown here match the corresponding values on the controller s front panel A text message with brief description of the status is provided along side the LEDs If the controller generates any errors they are displayed in the Error Messages text box Click on the Last 10 Errors to view old errors 28 Software Application Auto Tune Tab This tab provides access to initiating the auto tuning process remotely as well as to observe the controller performance Adjust the control loop gain stability margin to a desired level low medium or high and click on
22. nels Check the Show Graph box for showing either single channel or dual channel display Click on Save Data button to save the measured data If HTML file option is selected in the Options tab all the graphs are saved in the form of a report in HTML file format If Text file option is selected in the Options tab the measured data will be saved in two 2 files one for time response data and the other for frequency response data Users will be prompted to select desired filenames for these files The time response file contains five 5 columns in the following order time stamp damped data for channel 1 un damped data for channel 1 damped data for channel 2 un damped data for channel 2 The frequency response file contains five 5 columns in the following order frequency bins damped data for channel 1 un damped data for channel 1 damped data for channel 2 un damped data for channel 2 Software Application Sa SmartTable util v Tain fu 0 3640 Figure 20 Auto Tune Tab Screen showing dual channel display ia SmartTable Util 0 2898 DAMPING ENABLED 0 3640 DAMPING ENABLED Figure 21 Auto Tune Tab Screen showing single channel display 30 5 1 4 Software Application NOTE If the background color for a window is set to light blue then it is a control where users can enter values If the background color for a window is set to off white then it is a s
23. oration This manual has been provided for information only and product specifications are subject to change without notice Any change will be reflected in future printings Newport Corporation 1791 Deere Avenue Irvine CA 92606 USA Part No 41399 01 Rev B Preface Confidentiality amp Proprietary Rights Reservation of Title The Newport programs and all materials furnished or produced in connection with them Related Materials contain trade secrets of Newport and are for use only in the manner expressly permitted Newport claims and reserves all rights and benefits afforded under law in the Programs provided by Newport Corporation Newport shall retain full ownership of Intellectual Property Rights in and to all development process align or assembly technologies developed and other derivative work that may be developed by Newport Customer shall not challenge or cause any third party to challenge the rights of Newport Preservation of Secrecy and Confidentiality and Restrictions to Access Customer shall protect the Newport Programs and Related Materials as trade secrets of Newport and shall devote its best efforts to ensure that all its personnel protect the Newport Programs as trade secrets of Newport Corporation Customer shall not at any time disclose Newport s trade secrets to any other person firm organization or employee that does not need consistent with Customer s right of use hereunder to obtain access
24. ough the rear panel input power connector that provides in line transient protection and RF filtering The input power connector contains the fuses and the switch to select series or parallel connection of the transformer primaries for operation at lOOVAC 120VAC 220VAC or 240VAC Operating Temperature Smart Table Controller is designed for operation in a laboratory environment Recommended ambient operating temperatures are between 20 25 C Operation at higher or lower ambient temperatures for limited periods e g several hours will not cause any harm but may slightly reduce the performance 4 System Operation WARNING Before operating the Model Smart Table Series please read and understand all of Section 1 4 1 Power Switch Status LEDs 4 1 1 Front Panel The front panel of the Smart Table Controller is arranged for easy operation Seven distinct indicators and controls are located on the front panel that allows the user to operate the system as well as provide system status The front panel is shown in Figure 14 below CY Nevvport SMART TABLE CONTROLLER T 200 Outputs 1 and 2 STATUS 1 0 O SYSTEM AUTO TUNE gt m CHI im ia cS Auto Tune USB Port Button Figure 14 Front Panel Layout AC Power Switch When AC power is turned on the unit starts up in a default configuration with the OUTPUT off and the display in the SETPOINT mode The power switch is located in the lower left corner of
25. p gain has to be reduced at the end of auto tuning process The gain stability margin and the control loop gain determined by the controller have inverse relation While lower loop gain may be desired if the system is being used in an environment where the payload is continuously changing such lower gain will also result in reduced damping performance Data Acquisition e Enable FFT averaging Uncheck this box to cancel averaging by the application If this box is not checked the application will collect un damped or damped vibration levels only once e Number of averages Specify the number of times un damped damped vibration levels have to be collected and the FFT has to be averaged Monitoring amp Diagnostics e Payload change detection Uncheck this box to prevent the controller from detecting changes in the Smart Table payload that might necessitate tuning of control loop gains Feedback overload detection Uncheck this box to prevent the controller form monitoring the ambient vibration levels 32 9 1 5 4 Software Application Overload duration If feedback overload detection is enabled specify the amount of time for which feedback signal overload is allowed before the controller generates a warning message Enable auto ranging Uncheck this box if you do not want the pre amplifier gains adjust to vibration environment The box should be unchecked if the payload operation involves high vibration levels for short perio
26. pplicable European Union CE regulations and recommendations Fuses r Figure 5 Fuse Symbol The fuse symbol in the figure above identifies the fuse location on the Smart Table Controller Frame or Chassis Figure 6 Frame or Chassis Terminal Symbol The symbol in the figure above appears on the Smart Table Controller This symbol identifies the frame or chassis terminal On Figure 7 On Symbol The On Symbol in the figure above represents a power switch position on on the Model ST 200 Smart Table controller This symbol represents a Power On condition 1 1 8 1 1 9 1 1 10 1 1 11 Safety Precautions 11 Off Figure8 Off Symbol The Off Symbol in the figure above represents a power switch position on the Model ST 200 Smart Table controller This symbol represents a Power Off condition Protective Conductor Terminal 8 Figure 9 Protective Conductor Terminal Symbol The protective conductor terminal symbol in the above figure identifies the location of the bonding terminal which is bonded to conductive accessible parts of the enclosure for safety purposes The intent is to connect it to an external protective earthing system through the power cord USB Connector Symbol gt Figure 10 USB connector Symbol The USB connector symbol in the above figure identifies the location of the USB communications connector Mounting precaution The dampers are installed at two corners of the table adjacent to a lon
27. table If additional load is put on the table or subsequently taken from the table it is recommended to perform auto tuning Auto tuning must be performed also in the following cases e Amber blinking lights of one or both of CH1 and CH2 status LEDs e Audible sound from any of the two dampers USB Interface The instrument is designed to communicate with standard USB interfaces The cable required is a USB A B connection cable 24 System Operation NOTE With critical applications the radio frequency emissions while using the USB cable may be reduced by routing the USB cable through one or more ferrite cores such as the Fair Rite Products Corporation part number 0443164251 4 2 Rear Panel The Smart Table Controller rear panel shows the OUTPUT connectors and the AC power inlet CE CSA pane Frame or Chassis Terminal Voltage Model NEWPORT setting Number _H isan T0 Fike Label EESAC Channel 2 Damper Output Connector Channel 1 Damper Output Connector Figure 16 Rear Panel 4 2 1 Damper Output connectors Two 15 pin connectors labeled CH1 and CH2 are the connection points for the Smart Table active dampers 4 2 2 Frame or Chassis Terminal This terminal provides access to frame or chassis connection 4 2 3 AC Power Inlet Socket Plug the included power cord into the Power Inlet Socket on the rear of the instrument then plug the power cord into a wall socket with proper earth grounding 5 1
28. table ST 200 Controller Two 15 pin damper cables oe Yo Power cord 5 User s Manual If you are missing any hardware or have questions about the hardware you have received please contact Newport 19 20 3 4 3 9 3 6 3 7 Getting Started Choosing and Preparing a Suitable Work Surface Smart Table Controller may be placed on any reasonably firm table or bench during operation Position the controller so that there is easy access to the power cord The front legs of the unit can be pulled out to tilt the unit at an angle if desired Do not put the Controller on or attach to the isolated table Manual operation of front panel controls will disturb mechanically the normal operation of the system Electrical Requirements Before attempting to power up the unit for the first time the following precautions must be followed WARNING To avoid electric shock connect the instrument to properly earth grounded 3 prong receptacles only Failure to observe this precaution can result in severe injury e Have a qualified electrician verify the wall socket that will be used is properly polarized and properly grounded Provide adequate distance between the Smart Table Controller and adjacent walls for ventilation purposes Approximately 2 inch spacing for all surfaces 1s adequate Set the mains selector tumbler to the voltage that matches the power outlet AC voltage Power Supplies AC power is supplied thr
29. tatus window Manual Tune Tab This tab provides direct control over the control loop gain used by the controller It is recommended that users Auto Tune their system first and use the loop gains determined by the controller as a basis for fine tuning the loop gains Click on Apply Changes button in order for the application to send the desired loop gains to the controller and save them in the controller s non volatile flash memory In case your changes produces undesirable effect manifested by tonal noise from the dampers blinking amber lights of the Status LEDs on the front panel or blinking amber lights on the Status tab click the Disable damping button and reverse the erroneous changes The Enable Damping Measure Un damped Vibration Level Measure Damped Vibration Level and Save Data buttons behave the same way as described in the Auto Tune Tab section G3 SmartTable util YOO Newport SMART TABLE CONTROLLER ST 200 ext Status l Auto tune Manual Tune Options l About pencil eee ei Time Resp 0 2002 a A AM Alou A NAA aL N TTA Enable Notch Fitter won NM MEE AT ALP E A AT O MA e a nN 2 D S 5 Amplitude microns 1000 0 Notch Freq Hz 10 0000 gi DAMPING ENABLED 30 0000 l l l 1 l l l V Show Graph 0 00 0 05 0 10 08 15 0 20 025 0 30 0 35 O40 0 45 0 50 Channel 2 ee ee l 0 3640 Control Loop Gain Enable Notch Fitter 1000 0 Notc
30. tective Conductor Terminal Symbol essen 11 Figure 10 USB Connector Sy MDG laeran A twee 11 Figure 11 Locations of warnings on the rear panel cccccccecceeeeeeeeeeeees 13 Figure 12 Typical Comp lance Curve civ iaccenvesscisavinecconweyegesecesnedeavessdaaniocaceonxt 16 viii Preface Figure 13 Figure 14 Figure 15 Figure 16 Figure 17 Figure 18 Figure 19 Figure 20 Figure 21 Figure 22 Figure 23 Figure 24 Effect of damping on table vibration levels cesses 17 Front Panc tLaYOU beacons ia E E 21 BNC output SENSITIVITY cciscscscenieisbecdeeedes decades vtdedcbesdobadededeecedectoccdeced 23 Rear Pane boenen aa a aa a a 24 Smart Table Util Software ICON cccccsssessssessssseeeeeeeeeees 25 PO OUL BaD OCl ee ie taint tates dace ah ape tid dente hi O 26 Slats Va BD SCre Cis cedacsice ws Coteau eetaata teases mele aaevenitss 2 Auto Tune Tab Screen showing dual channel display 29 Auto Tune Tab Screen showing single channel display 29 Martial Tane Tap Sere iiss yc insscicvuccsheccaivacdereatanyccpineiesdecaneecsnmses 30 Options Fal S CROC isesi ne Sachi al tesicaad dente haeteada ETO 32 Fuse Replacement agina a dos OG eae ee 34 List of Tables Table 1 Table 2 Table 3 Table 4 Table 5 SPECIEI ON rauraa T T N 16 Smart Table Controller Specifications 2 0 0 cceecccccceceeseeeeeeeeeeees 18 Envoronmental Specifications cccccccccssssssssseseeeecceeeeeeeeeeeeeeaee
31. the instrument front panel 21 22 System Operation 4 1 2 Status The table below shows the meaning of the various colors of SYSTEM CH1 and CH2 status LED s ystem Level Category Comment LED LED LED o 4 System Powered Controller performing selcheck AMBER 5 System Powered No system probem lt GREEN 6 System Fault Controler firmware non functional RED _ 7 Chane Fault Damper notconneced RED GREEN 8 Channei1 Fault Channel shutdown due to Damper Fault B RED GREEN 9 Channei1 Fault Channel shutdown due to Payload Change B AMBER GREEN 10 Channel 1 Warning Channel operating in overload condition AMBER GREEN 11 Channel Tuning Auto tuning in process B GREEN GREEN 12 Channel 1 Damping Normal operation GREEN GREEN 13 Channel 1 Disabled Channel shutdown via sofware OFF GREEN 14 Channel2 Fault Damper notconnected RED GREEN 15 Channer2 Fault Channel shutdown due to Damper Faut B RED GREEN 16 Channer2 Fault Channel shutdown due to Payload Change B AMBER GREEN 17 Channer2 Warning Channel operating in overload condition AMBER GREEN 18 Channel2 Tuning Auto tuning in process B GREEN GREEN 19 Channel 2 Damping Normal operation GREEN GREEN 20 Channel 2 Disabled Channel shutdown via sofware OFF GREEN Table 4 Definition of SY
32. to be defective during the warranty period the product will either be repaired or replaced at Newport s option To exercise this warranty write or call your local Newport office or representative or contact Newport headquarters in Irvine California You will be given prompt assistance and return instructions Send the product freight prepaid to the indicated service facility Repairs will be made and the instrument returned freight prepaid Repaired products are warranted for the remainder of the original warranty period or 90 days whichever first occurs Limitation of Warranty The above warranties do not apply to products which have been repaired or modified without Newport s written approval or products subjected to unusual physical thermal or electrical stress improper installation misuse abuse accident or negligence in use storage transportation or handling This watranty also does not apply to fuses batteries or damage from battery leakage THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR USE NEWPORT CORPORATION SHALL NOT BE LIABLE FOR ANY INDIRECT SPECIAL OR CONSEQUENTIAL DAMAGES RESULTING FROM THE PURCHASE OR USE OF ITS PRODUCTS First printing 2004 2004 by Newport Corporation Irvine CA All rights reserved No part of this manual may be reproduced or copied without the prior written approval of Newport Corp
Download Pdf Manuals
Related Search
Related Contents
Thomson Boombox RCD150 平成 27 年度第 2 回 A2142 ff RIDA AllergyScreen Panel 1 2 3 4 13-09 - R 取 扱 説 明 書 Rexel PP Dividers, grey, numerical Sun Server X3-2 Administration Guide MODO DE EMPLEO PROPIEDADES FÍSICAS SALUD Y Fiche Technique Ordonnance collective signée - Centre intégré de santé et de JVC LYT1354-001B Camcorder User Manual Copyright © All rights reserved.