        MC8022 Covermeter
         Contents
1.     The MC8022 has two measurement ranges     High and Low   Change range by pressing the right hand yellow button  Range    An indicator on the right hand side of the screen shows Hi or Lo     The High range is more   sensitive so it can measure  greater cover depths  When  locating a bar or measuring    Maximum cover    6mm 110mm 70mm    cover  you should normally 40mm 185mm 90mm    use the High range to avoid   missing deep bars  However    when trying to find the orientation of bars that are closely spaced   try the Low range because it is less affected by nearby bars     Set the bar size    Cover measurement is only accurate if the bar size is known  reasonably precisely     If you Know the bar size  press the  middle yellow button  BAR  to set  the value shown on the Cover depth  page  Pressing  BAR  selects the next  available bar size  In the picture  the  bar size has been set to 16mm     Cover derth OS  Slam    e am 16mm    iL 14  85 Hi    To locate a bar and estimate its size automatically  see    Automatic  bar sizing    below  this will set the current bar size to the measured  value     Quick bar location    To quickly find the approximate position of a bar  look at the top of  the probe whilst slowly sweeping the probe over the search area     The red bar indicator light flashes   briefly when the signal detected from  a bar is near its peak and this can be  used as a quick guide to bar location     For more precise location follow the  procedure below     K KO
2.  and alignment is  found  read the cover as before       n some situations an alternate method is useful to map out the  Orientation of bars  First sweep the probe in a straight line until   you find a bar  bar indicator light   lowest cover   maximum signal    Mark this position  Now perform a second sweep in the same  direction but some distance from the first and again mark the bar  position  A line drawn between these marks gives the orientation of  the bars  Keeping the probe parallel to the bar orientation  perform  a third sweep to find the centre of the bar  The location of parallel  bars can now be marked by extending the sweep either side of the  first bar     Audio cover mode    MC8022 has an audible indication   te Menu  of detection strength which helps Volume 5  to locate bars without having to  watch the display  To use Audio cover  indication  go to Settings  select  Audio and set Mode to    Cover     You  can also adjust the volume from this menu     a  OW cover 45       A       Fe    Now when you sweep the probe over the search area  you will hear  a tone that increases In pitch as you get closer to a bar and reaches  its highest pitch when the probe is aligned with the bar     set the audio Mode to    Off    to stop the tone              The MC8022 can be used to automatically calculate the size of  covered rebar     First  align the probe with the centre line of the bar to be measured  using the bar search process above     Keeping the probe in the same po
3.  used for a few months  connect  the charger for 1 2 hours before  storing the instrument  and then  fully recharge the battery before it  is used again     To recharge the battery  switch the instrument off and connect  the supplied charger to the left hand connector on the instrument   Charging the battery to 95  of capacity takes about 2 5 hours   Leave the charger connected for 3 4 hours for a full recharge     Only use the supplied battery charger  Using any other type of  charger may result in reduced battery performance or damage to  the equipment  Damage caused by using an unsuitable charger   is not covered by warranty  If the charger is damaged  obtain a  genuine spare part from Kolectric Research or your local agent   Always replace the connector sealing cap after charging to prevent  ingress of dust and moisture        Setting the date and time    MC8022 has an internal clock which is used to timestamp logged  data  The time  date and display format  12 hr or 24 00 hr  d m y or  m d y  can be set from Date and Time     Display the Settings by pressing the  red button three times     Press the right hand yellow button   VW   to move down the menu until  Date and Time is highlighted  Press  the middle yellow button  SELECT  to adjust the Date and Time        Use the yellow buttons   A   and     V   to move up and down the menu  and       to change the selected  setting        When finished  press the red button  to return to Settings     Setting the measurement unit
4. Kolectric Research          Getting Started    Maintenance   Measuring Cover   Automatic Bar Sizing   Low Cover Scanning   Custom Cover Tables   Data Logging and Download  Installing Download Software  Specification    Repair and Disposal    Kolectric Research  New Forest Enterprise Centre  southampton  S040 OLA  UK    Phone  44  0 23 8066 0127  Email sales kolectric com  www kolectric com    KOLECTRIC    RESEARCH    12 40enm           30mm  Be   Function    RANGE   button labels  Battery  charger Probe  amp   connection Download  connection  Function  buttons  Power    Mode button  MICRO COVERMETER  Probe cable       Data log button       Sole plate    replace when worn    Bar indicator light       Controls and Display    switch the MC8022 on by pressing and holding the red button  until the display shows the instrument name and serial number   The display quickly changes to show the normal controls and cover  reading     Cover derth 08  16am    os Zimm    LI Oo Hi  CAL   BAR   RANGE    Kolectric    MC8022    sm 829001 issue 1 00    Press the red button briefly to change the displayed control page   These pages are shown in turn     Cover depth Normal display for measuring cover depth    Bar size Automatic bar size measurement   Data log Review logged data   Settings Configure measurement  logging  audio and  time  amp  date    Page labels and menu items are shown in this manual like this  Cover depth    The three yellow buttons have different functions depending on  which c
5. LECTRIC    RES EAR CH    Bar size Hi range Lo range    CAL   BAR   RANGE          Precise bar location and cover measurement    Hold the yellow face of   the probe flat against the  concrete surface  Move   the probe over the surface  whilst watching the cover  depth display  The probe is  positioned roughly over a bar  when the cover depth reading  is at Its lowest     Keeping the probe over the  same spot  rotate it around  its centre  When the lowest  cover reading is seen  the  probe body has been aligned  with the direction of the bar     Now the bar orientation is  known  slowly sweep the  probe  keeping it parallel to  the bar  The lowest cover  reading will now correspond  to the center line     Once you have found a bar and aligned the probe to it  you can read  the cover depth from the display                f you want to log this cover reading  press the yellow button on  the probe  This will record the cover depth  bar size  time and date  and can be viewed on the MC8022 or downloaded to a PC later if  required   See Data logging  below     For maximum precision follow the same procedure but instead of  watching for minimum cover  look for maximum signal strength  reading     Signal strength is shown below the Cover derth 08 18am  main cover depth readout  in smaller Sum Zon  numbers     1854 in the picture  r ca a    CAL   BAR   RANGE       The signal strength reading is at its  greatest when the probe is aligned  with the centre line of a bar  When this position
6. ate the probe    Calibration must be performed every time you switch the  instrument on     To remind you  the Cover depth display will show Omm  0 00in   until calibration is performed        Connect the probe cable to the connector on the right hand side of  the MC8022  Align the white index marks on the connectors  push  the plug onto the instrument connector  then turn the locking ring in  the direction of the green arrow  Press the red button to switch on  the MC8022     Calibrate the instrument by holding River derth O08  17am  the probe in the air at least 1m away 20mm  from metal objects and magnetic Calibrating     fields  such as keys  rings or coins  a  fluorescent lights  mobile phones or  computer screens        CAL   BAR   RANGE    Press and release the left hand yellow button  GAL   The  instrument will beep when the button is pressed and beep again  when calibration is complete  The display changes to show 120mm   Lo  or 200mm  Hi  depending on the range selected     Move the probe towards a metallic Cover derth  O8 17am  object and note that the cover display 200 201mm  changes from 120 mm or 200 mm to a i    smaller reading           Hi    BAR   RANGE       These simple checks confirm that the  instrument is functioning and ready for use     To get the best possible results  calibration should also be  performed periodically if you are making large numbers of  measurements and especially before making measurements of  deep cover     Set the measurement range
7. cable into your PC s  USB port     Run the download software using the shortcut    Kolectric MC802x  download        Click the Download button  The logged data appears in the  download software window     To save the data to your PC  click    Save File    and choose a suitable  filename  By default  this will save all the downloaded data  To  save a specific range of data  enter the first and last required record  numbers before clicking Save File     When all the data required has been downloaded and saved  clear  the Covermeter s memory by clicking    Clear Log     This removes all  logged data from the MC8022     You can also set the MC8022 time and date from the download  software           The MC8022 Download Kit includes software to copy logged cover  readings onto a PC using a USB cable  If your MC8022 kit was   not purchased with the download cable and software  it can be  purchased directly from Kolectric Research     Kolectric download software is designed for Windows XP or  Windows 7  You may need administrator rights to successfully  install the software  Ask your IT advisor if in doubt     You must install the software BEFORE connecting the download  cable     Insert the USB memory stick into your PC  Open the root folder for  the USB disk and run    setup exe        Follow the on screen Instructions     When the installation is complete  plug the download cable into the  right hand connector on the MC8022  disconnect the probe cable  first   Connect the other en
8. d of the cable to a USB port on your PC   switch the MC8022 on     The software creates a new program shortcut      Kolectric Research   Kolectric MC802x download       Run this to start the software     SPECIFICATION    Cover Measurement    Cover depth indicated is from the bar surface  Performance meets  or exceeds the requirements of BS1881 part 204 1988 when  instrument has been tested and certified compliant by Kolectric  Research and is operated according to this user manual     Bar Size Cover Range Cover depth Accuracy  6 mm bar omm     108 mm up to 60 mm cover  1 mm  40mmbar 22mm     185mm up to 120 mm  2 mm  up to 160 mm  3 mm  over 160 mm  4 mm    Automatic Bar Sizing    Accuracy  0 5mm      1 5mm  Resolution 0 1mm    Minimum Cover 8 mm     22 mm minimum cover depending    on bar size    Maximum Cover 6 mm bar up to 60 mm cover  40 mm bar    up to 80 mm cover    Bar Resolution    Bar resolution is dependent on bar size and cover  Typical examples of  resolution performance are shown     Bar Size Cover Minimum Spacing  16mm 60mm 70mm   16mm 100mm 110mm   25MM 130mm 150mm    Operating Parameters    Operating Weight 800g  instrument probe cable     Operating Temp  10  C      50  C  Battery Operation 20 hrs  Battery Charger 110     240V AC  Ingress Protection IP65  ani    REPAIR AND DISPOSAL    Repair    There are no user serviceable components inside the equipment   Opening the equipment voids any warranty       f you damage your MC8022 or it malfunctions during the wa
9. ings  will be deleted  Press the red button to exit without clearing the    log     The Overwrite option can be used so that the MC8022 always  stores the latest readings and automatically deletes older readings  as new ones are logged  Switch this option on to overwrite old  data  When Overwrite is switched off  the MC8022 will stop  logging when the memory is full  protecting previous readings     Logging Cover readings    When measuring cover  press the Shier terth  o amp   20am  yellow button on the probe to log the 35  current cover depth  The instrument a  beeps to confirm that the data has  been recorded and the display briefly  shows    Log    below the bar size     16mm  Log      1504 Hi  CAL   BAR   RANGE    K KOLECTRIC    RESEARCH          Reviewing Cover readings    To review logged data on the Data log 08  23am  MC8022  press the red button to Cover 72 mm  display the Data log page     Bar 20 mm  Or O08 14 O8 23 31           The display shows the latest recorded  reading  To see older readings press  the right hand yellow button   W     to see newer readings use the  left hand yellow button   A       Downloading    The optional MC8022 download kit includes a USB cable and  software to transfer logged data to a PC  Follow the instructions in  the next section to install it on your PC     To copy logged cover readings to a PC  first unplug the probe cable  and connect the download cable to the right hand connector on the  MC8022  Plug the other end of the download 
10. ontrol page is being used  The active function is shown on  the display just above each button  In this manual button labels are  shown like this  SELECT      When changing Settings  the left   A   and right   W   yellow  buttons move up and down through the list of settings  the middle  yellow button is pressed to select a menu item  SELECT  or  change a setting       and the red button is used to move back to  the previous menu     K KOLECTRIC    RESEARCH       Switch the instrument off by pressing the red button for about two  seconds until the screen shows the Settings display  The first  option in the list  Switch off  is highlighted  Press  SELECT  to  turn the instrument off  The instrument can be switched off in any  mode and will switch off automatically after 10 minutes if there  have been no key presses     Backlight    The display is designed to be visible in normal daylight conditions   For use in darker environments  turn on the backlight     Press the red button to display Settings  then select  Measurement     Now select Backlight and use the middle yellow button         to  turn it on or off     Charging the battery    MC8022 contains a rechargeable battery that provides about 20  hours of typical operation  When operating  the battery indicator at  the left hand side of the Cover depth display shows approximately  how much charge is in the battery     The instrument should be fully  charged before first use in the field   If you know the MC8022 will not   be
11. required cover   depth  pressing and holding the button to rapidly step through the  available cover range     Press the red button twice to return to the Cover depth display     Sweep the probe over the area to be checked  An alarm is heard if  a bar is detected with low cover     Turn off Low Cover mode from the Audio menu when the search is  complete        The MC8022 can be used to assess cover over non standard bar   pipes or other inclusions in pre fabricated structures  This process  requires preparation of a custom depth table and setting the  measurement units to an arbitrary scale of 0 1000  Contact your  Kolectric reseller for advice on using custom cover tables        MC8022 can log cover readings as you make them so that you can  review them later or download them to a PC     Prepare for Data logging  Before starting a new set of measurements  prepare as follows     Turn the MC8022 on  Check the time displayed on the Cover depth  page and make adjustments If necessary using the Data and Time  menu in Settings     The MC8022 can store 2000 readings  It is good practice to  regularly review or download the data you need and then clear the  memory on the MC8022     First  check that you have reviewed or downloaded any previous  logged data that might be needed     Data Lod menu    Go to the Settings and select Data    log    verurite OFF  Ll ear os    Boe    select Clear log     the display will  show    Sure      Select Clear log a   second time and all stored read
12. rranty  period  please contact your reseller or Kolectric Research directly to  arrange for assessment and repair     Recycling    MC8022 contains sophisticated electronics which include valuable  materials which can be recovered by an appropriate waste  electrical and electronic equipment  WEEE  recycling process  The  equipment is marked with the crossed out wheeled bin symbol to  remind you to recycle the equipment separately from household  waste     Battery    MC8022 contains a lithium ion battery pack  This is designed to  last the lifetime of the instrument and should only be replaced  or  removed for disposal  by Kolectric Research  a qualified service  agent or an authorized WEEE recycling centre     Further details are available directly from Kolectric Research     Kolectric Research  New Forest Enterprise Centre  southampton  5040 9LA  UK    Phone  44  0 23 8066 0127  Email sales kolectric com  www kolectric com       
13. s    Cover depth and bar size can be displayed in millimeters or inches  to suit local requirements     A third option is provided to display cover depth in arbitrary units   0 1000   This scale is used with custom depth tables     To change measurement units    go to Settings and then select  Measurement  Scroll to Cover units  and press the middle yellow button to  change the setting     Measurement menu    rs  acklidg   r          Maintenance    MC8022 should be kept clean using a damp cloth  Do not immerse  in water  Do not use solvent or abrasive cleaners     The bottom of the probe is protected by a replaceable yellow plastic  plate  This will wear as the probe is run over concrete    t should   be peeled off and replaced periodically to protect the main probe  housing  Self adhesive replacements are included in each MC8022  kit and spares are available direct from Kolectric Research     Certification    The MC8022 Covermeter should be tested for compliant  performance periodically  the recommended interval is 12 months   Complete units should be packed appropriately and returned to  Kolectric Research for testing and certification     There are no user serviceable components inside the equipment  and opening the equipment voids any warranty     K KOLECTRIC    RESEARCH    Use the following process to measure cover     1  Connect and Calibrate the probe  2  Set the measurement range   3  Set the bar size   4  Locate the bar   5  Read the cover depth    Connect and Calibr
14. sition  press the red button to  select the Bar size page  Initially this will show the detected  signal level  You can adjust the position of the probe so that the  reading is at its highest indicating the best alignment of the probe  with the bar     Now press the left yellow button  SIZE  to calculate the bar size     When the process is complete  the OS  19am  display shows the bar size  The 690  instrument will indicate if the target  bar is too near or too far to complete  the calculation  If the bar is too near   a plastic spacer can be used to hold  the probe away from the bar     Calculating     SIZE     SIGNAL    Press the right yellow button Bar size OS  19am   SIGNAL  to show the detected level 16 4  again to repeat the process  E    Press the mode button to change back   S  ZE    STGHAL  to cover depth mode and note that   the bar size shown in the top right of the display has been updated  automatically  ready for cover depth measurements     4 KOLECTRIC    RESEARCH       The MC8022 can be used to quickly check a large area for proper  cover     To use Low Cover Scanning  configure the MC8022 as follows     Press the red mode button to show the Settings page  then select  Audio  Press the middle yellow button       to change the audio  Mode to    Low cover        Adjust the volume according to the Audio menu  environment  Yoluma    a  MERE Low cover  OW cover 45    Move to the Low Cover setting  and use the middle yellow button atin                to select the 
    