SUPERSERVER 6027R-TRF
Contents
1. 5 11 SATA Drive Connections Serial ATA Ports SATA Ports Pin Definitions SATAO SATA3 Pin Definition Pin Definition There are six Serial ATA Ports I SATAO I SATA 5 located on the motherboard I SATA 0 1 support SATA 1 Ground 5 RX N 3 0 and I SATA 2 5 are SATA 2 0 ports 2 TAE 6 RXP These ports provide serial link signal o N 7 Ground 4 Ground connections which are faster than the connections of Parallel ATA See the table on the right for pin definitions 5 27 SUPERSERVER 6027R TRF USER S MANUAL 5 13 Installing Drivers The CD that came bundled with the system contains drivers some of which must be installed such as the chipset driver After inserting this CD into your CD ROM drive the display shown in Figure 5 7 should appear If this display does not appear click on the My Computer icon and then on the icon representing your CD ROM drive Finally double click on the S Setup icon Click the icons showing a hand writing on paper to view the readme files for each item Click the computer icons to the right of these items to install each item from top to the bottom one at a time After installing each item you should reboot the system before moving on to the next item on the list The bottom icon with a CD on it allows you to view the entire contents of the CD Figure 5 7 Driver Tool Installation Display Screen amp SUPERMICRO X9DR3 i F Motherboard Dri
2. Front Panel Accessible USB Connections Backpanel VGA Port 5 15 SUPERSERVER 6027R TRF USER S MANUAL use a power supply that contains a 24 pin and two 8 pin power connectors Be sure to connect these power supply connectors to the 24 pin power connector JPWR3 and two 8 pin power connectors JPWR1 JPWR2 on the motherboard Failure in doing so will void the manufacturer warranty on your power supply and motherboard Warning To prevent damage to the power supply or motherboard please 5 8 Connector Definitions Power Connectors ATX Power 24 pin Connector A 24 pin main power supply Pin Definitions JPWR3 connector JPWR3 and two 8 pin CPU Pin Definition Pin4 Definition PWR connectors JPWR1 2 are located eds i ses on the motherboard These power Lc ad 2 498v connectors meet the SSI EPS 12V i5 Geox 3 Gout specification These power connectors 16 PS ON 4 8V must also be connected to your power 17 COM 5 COM supply See the table on the right for 18 COM 6 5V pin definitions 19 COM 7 COM Warning To provide adequate power 20 ROSINO PWR_OK supply to the motherboard be sure to ENESA 2 NSS connect the 24 pin ATX PWR JPWR3 cll Bid e and two 8 pin PWR connectors JPWR1 ESY EAE JPWR2 to the power supply Failure 24 COM VM RRN to do so will void the manufacturer warranty on your power supply and 12V 6 pin PWR Connector Pin Definitions JPWR
3. Use this feature to select data transfer speed for QPI Link connections The options are Fast and Slow QPI Link Frequency Select Use this feature to select the desired QPI frequency The options are Auto 6 4 GT s 7 2 GT s and 8 0 GT s DIMM Configuration Total Memory This item displays the total memory size available in the system Current Memory Mode This item displays the current memory mode Current Memory Speed This item displays the current memory speed Mirroring This item displays if memory mirroring is supported by the motherboard Sparing This item displays if memory sparing can be supported by the motherboard gt DIMM Information CPU Socket 1 DIMM Information CPU Socket 2 DIMM Information The status of the memory modules detected by the BIOS will be displayed Memory Mode When Independent is selected all DIMMs are available to the operating system When Mirroring is selected the motherboard maintains two identical copies of all data in memory for data backup When Lockstep is selected the motherboard uses two areas of memory to run the same set of operations in parallel The options are Independent Mirroring Lockstep and Sparing DRAM RAPL BWLIMIT This item sets the limits on the average power consumption and the bandwidth of a DRAM module in operation so that the OS can manage power consumption and energy budget of hardware more effectively within a certain window of time The optio
4. VCC with 1 5A PTC current limit Legacy Wake On LAN Header Pin Definitions JSTBY Pin Definition 1 45V Standby 2 Ground Wake up signal SUPERSERVER 6027R TRF USER S MANUAL 5 9 Jumper Settings Explanation of Jumpers To modify the operation of the motherboard jumpers can be used to choose between optional settings Jumpers create shorts between two pins to change the function of the connector Pin 1 is identified with a square solder pad on the printed circuit Pins Jumper Cie board See the diagram at right for an example of jumping pins 1 and 2 Refer to the motherboard layout page for jumper locations Note On two pin jumpers Closed means the jumper is on and Open means the jumper is off the pins CMOS Clear JBT1 contact pads JBT1 is used to clear CMOS which will also clear any passwords Instead of pins this jumper consists of contact pads to prevent accidentally clearing the contents of CMOS To Clear CMOS 1 First power down the system and unplug the power cord s It is also recommended that you remove the onboard battery from the serverboard 2 With the power disconnected short the CMOS pads with a metal object such as a small screwdriver 3 Remove the screwdriver or shorting device 4 Reconnect the power cord s and power on the system Note Do not use the PW_ON connector to clear CMOS LAN Enable Disabl
5. to add color and function key support Select ANSI to use the extended ASCII character set Select VT UTF8 to use UTF8 encoding to map Unicode characters into one or more bytes The options are ANSI VT100 VT100 and VT UTF8 Bits Per Second This item sets the transmission speed for a serial port used in Console Redirection Make sure that the same speed is used in the host computer and the client computer A lower transmission speed may be required for long and busy lines The options are 9600 19200 38400 57600 and 115200 bits per second Data Bits Use this feature to set the data transmission size for Console Redirection The options are 7 and 8 Bits Parity A parity bit can be sent along with regular data bits to detect data transmission errors Select Even if the parity bit is set to 0 and the number of 1 s in data bits is even Select Odd if the parity bit is set to 0 and the number of 1 s in data bits is odd Select None if you do not want to send a parity bit with your data bits in transmission Select Mark to add mark as a parity bit to be sent along with the data bits Select Space to add a Space as a parity bit to be sent with your data bits The options are None Even Odd Mark and Space Stop Bits A stop bit indicates the end of a serial data packet Select 1 Stob Bit for standard serial data communication Select 2 Stop Bits if slower devices are used The options are 1 and 2 Flow Control This feature a
6. long beep 5 long and 2 short Display memory Video adapter missing or with faulty memory beeps read write error 1 Continuous beep System OH System Overheat A 1 SUPERSERVER 6027R TRF USER S MANUAL Notes Appendix B System Specifications Appendix B System Specifications Processors Dual Intel E5 2600 Series series Socket R LGA2011 type processors Note You must install at least two processors for full functions to be supported Note Please refer to our web site for a complete listing of supported processors Chipset One Intel PCH C602 chipset and one Intel PCH C606 Southbridge chipset BIOS 64 Mb AMIBIOS SPI Flash ROM Memory Capacity Sixteen 16 single dual tri quad channel DIMM slots supporting up to 512 GB of DDR3 1600 1333 1066 800 MHz speed 1GB 2GB 4GB 8GB 16GB and 32GB size registered ECC SDRAM Note See the memory section in Chapter 5 for details SATA Controller Intel PCH C606 on chip controller for six port Serial ATA RAID 0 1 5 and 10 supported Drive Bays Eight hot swap drive bays to house eight SATA or SAS drives SAS requires optional SAS controller card Peripheral Drive Bays One 1 slim DVD ROM drive Expansion Slots Three 3 PCI Express 3 0 x16 card slots Slot2 Slot4 Slot6 and Three 3 PCI Express 3 0 x8 slots Slot1 Slot3 Slot5 for standard size add on cards B 1 SUPERSERVER 6027R TRF USER S MANUAL Serverboard X9DRi F ATX form factor Dimensions 12
7. Clock 8 NC NC No Connection DOM Power Connector DOM Power A power connector for SATA DOM Pu Disk On Module devices is located Pin amp Definition at JWF1 Connect an appropriate cable ET here to provide power support for your P Ground DOM devices F Chana BIOS Recovery ME Recovery JP3 BIOS Recovery is used to Pin Definitions enhance system performance and iPad da power efficiency In the single operation 1 No Connection mode online upgrade will be available 2 Signal via Recovery mode See the table on e croua the right for pin definitions 5 22 ATX PS 2 Keyboard and PS 2 Mouse Ports The ATX PS 2 keyboard and PS 2 mouse are located on the back panel of the motherboard See the table at right for pin definitions Legacy Wake On LAN Header JSTBY The onboard LAN por ts do not need a WOL header to support their Wake On LAN function Instead the legacy WOL header was preserved JSTBY to provide convenience for some embedded customers who need an internal power source from the board See the table on the right for pin definitions 5 23 Chapter 5 Advanced Serverboard Setup PS 2 Keyboard Mouse Pin Definitions PS2 Keyboard PS2 Mouse Pin Definition Pin Definition 1 KB Data 1 Mouse Data 2 No 2 No Connection Connection 3 Ground 3 Ground 4 Mouse KB 4 Mouse KB VCC 5V VCC 5V 5 KB Clock 5 Mouse Clock 6 No 6 No Connection Connection
8. Explanation of J mpers nn rnt 5 24 Onboard Indicators cnr erp tp ce EEES 5 26 SATA Drive ConnectiOris ceri ep rfe oet 5 27 Installing PITT TREES 5 28 Supero Doctor ll ihrer andra EXPE OPERE UTOR 5 29 Chapter 6 Advanced Chassis Setup Static Sensitive DeviCeS 2 iet a a ERE acters cce crude 6 1 Precautions 1 rtr trn e ei nine nde e v i e e der dus 6 1 Unpacking Sic ccaten ccs ce tides e uberi e catered codeine dar erre E EA TERR Pet 6 1 Control Panel neret rtr errore ere nina erra d e Tor EDGE 6 2 cha T 6 3 System Fan FE il re ii te eR ek nee acl Aes 6 3 Replacing System Fans sse 6 4 6 5 7 1 7 2 7 3 7 4 7 5 7 6 77 Drive Bay Installation Removal eren nnne 6 4 Accessing the Drive Bays ci ciere erret pre tr EE pr ve EP TEE since 6 4 SATA Drive lIristallatioh c i c trabe edere 6 5 Hard Dive Backplane iis siscsacccesiesseneecssenesecencddacachs n erre eren ani 6 6 DVD ROM Installation rera tte Eh arr reta 6 7 Power Supply e Y 6 8 Power Supply Failure 2 35 dr ctore tete c de pce 6 8 Removing Replacing the Power Supply sss 6 8 Chapter 7 BIOS IntrodlctlOh irte rr etre nen eterna ees 7 1 Starting the Setup Utility riisiin arasi notre eret 7 1 Main MOI M 7 1 System Time System Date ssssss
9. When the dialog box appears asking you if you want to restore user s defaults click Yes to restore the user s defaults previously saved in the system or click No to abandon the user s defaults that were previously saved Boot Override This feature allows the user to enter a new setting to overwrite the original setting that was saved for the following devices e IBA GE Slot 0400 v1376 e UEFI Built in EFI Shell PO ST91000640NS 7 26 Appendix A BIOS Error Beep Codes Appendix A BIOS Error Beep Codes During the POST Power On Self Test routines which are performed each time the system is powered on errors may occur Non fatal errors are those which in most cases allow the system to continue the boot up process The error messages normally appear on the screen Fatal errors are those which will not allow the system to continue the boot up procedure If a fatal error occurs you should consult with your system manufacturer for possible repairs These fatal errors are usually communicated through a series of audible beeps The numbers on the fatal error list on the following page correspond to the number of beeps for the corresponding error All errors listed with the exception of Beep Code 8 are fatal errors A 1 AMIBIOS Error Beep Codes Beep Code Error Message Description 1 beep Refresh Circuits have been reset Ready to power up 5 short beeps and1 Memory error No memory detected in the system
10. a Pin Definitions A Chassis Intrusion header is located JL1 at JL1 on the motherboard Attach an appropriate cable from the chassis to Pin Definition 1 Intrusion Input inform you of a chassis intrusion when ae 2 Ground the chassis is opened Power LED Speaker PWR LED Connector On JD1 header pins 1 3 are used for Pin Definitions GIO power LED indication and pins 4 7 are Pin Setting Definition for the speaker See the tables on the Pin Anodelz right for pin definitions Please note Pine Cathode Pin3 NA that the speaker connector pins 4 7 are used with an external speaker If Speaker Connector you wish to use the onboard speaker Pin Definitions you should close pins 6 7 with a jumper Pin Setting Definition Default Pins 4 7 External Speaker Pins 6 7 Internal Speaker Default 5 20 TPM Header Port 80 A Trusted Platform Module Port 80 header is located at JTPM1 to provide TPM support and Port 80 connection Use this header to enhance system performance and data security See the table on the right for pin definitions Overheat LED Fan Fail The JOH1 header is used to connect an LED indicator to provide warnings of chassis overheating and fan failure This LED will blink when a fan failure occurs Refer to the tables on right for pin definitions Power SMB I C Connector Power System Management Bus 12C Connector JI2C1 monitors power sup
11. a port specified by the user so that the user is allowed to change a hardware component or a device without shutting down the system The options are Enabled and Disabled Staggered Spin up Select Enabled to enable Staggered Spin up support to prevent excessive power consumption caused by multiple HDDs spinning up simultaneously The options are Enabled and Disabled RAID Mode The following items are displayed when RAID Mode is selected PCH RAID CodeBase Set this item to Intel or LSI to specify the codebase to be used for RAID sup port The options are Intel and LSI Port 0 5 Hot Plug Select Enabled to enable hot plug support for a port specified by the user The options are Enabled and Disabled 7 14 Chapter 7 BIOS gt SAS Configuration If a SAS port is detected in the system the following items will be displayed SCU Devices Select Enabled to enable support for PCH SCU System Configuration Utility devices The options are Disabled and Enabled OnChip SAS Oprom Select Enabled to support the onboard SAS Option ROM to boot up the system via a storage device if a SAS device is installed The options are Disabled and Enabled SCU Port 0 7 The SCU devies detected by the BIOS will be displayed gt Thermal Configuration Thermal Management Select Enabled to initialize the PCH Thermal subsystem device The options are Enabled and Disabled If Enabled is selected the following item appears gt PCle PCI P
12. allows the user to set the PCI Exp bus speed between IOU1 and PCl e port The options are x4x4 and x8 Port 1A Link Speed Select GEN1 to enable PCI Exp Generation 1 support for Port 1A Select GEN2 to enable PCI Exp Generation 2 support for Port 1A Select GEN3 to enable PCI Exp Generation 3 support for Port 1A The options are GEN1 GEN2 and GENS IOU2 PCle Port This feature allows the user to set the PCI Exp bus speed between IOU2 and PCIe port The options are x4x4x4x4 x4x4x8 x8x4x4 x8x8 and x16 and Auto Port 2A Link Speed Select GEN1 to enable PCI Exp Generation 1 support for Port 2A Select GEN2 to enable PCI Exp Generation 2 support for Port 2A Select GEN3 to enable PCI Exp Generation 3 support for Port 2A The options are GEN1 GEN2 and GENS IOUS PCIe Port This feature allows the user to set the PCI Exp bus speed between IOU3 and PCIe port The options are x4x4x4x4 x4x4x8 x8x4x4 x8x8 and x16 and Auto Port 3A Link Speed Select GEN1 to enable PCI Exp Generation 1 support for Port 3A Select GEN2 to enable PCI Exp Generation 2 support for Port 3A Select GEN3 to enable PCI Exp Generation 3 support for Port 3A The options are GEN1 GEN2 and GEN3 GPI Configuration Current QPI Link This item displays the current status of the QPI Link Current QPI Frequency This item displays the current frequency of the QPI Link 7 9 SUPERSERVER 6027R TRF USER S MANUAL QPI Quick Path Interconnect Link Speed Mode
13. changes Save Options Save Changes Select this option and press lt Enter gt to save all changes you ve done so far and retun to the AMI BIOS utility Program This will not reset reboot the system When the dialog box appears asking you if you want to save configuration click Yes to save the changes or click No to return to the BIOS without making changes Discard Changes Select this feature and press lt Enter gt to discard all the changes and return to the BIOS setup When the dialog box appears asking you if you want to load previ ous values click Yes to load the values previous saved or click No to keep the changes you ve made so far Restore Defaults Select this feature and press lt Enter gt to load the default settings that help optimize system performance When the dialog box appears asking you if you want to load the defaults click Yes to load the default settings or click No to abandon defaults Save As User Defaults Select this feature and press lt Enter gt to save the current settings as the user s defaults When the dialog box appears asking you if you want to save values as user s defaults click Yes to save the current values as user s default settings or click No to keep the defaults previously saved as the user s defaults 7 25 SUPERSERVER 6027R TRF USER S MANUAL Restore User Defaults Select this feature and press lt Enter gt to load the user s defaults previously saved in the system
14. discharge Precautions Use a grounded wrist strap designed to prevent static discharge Touch a grounded metal object before removing any board from its antistatic bag Handle a board by its edges only do not touch its components peripheral chips memory modules or gold contacts When handling chips or modules avoid touching their pins Put the serverboard add on cards and peripherals back into their antistatic bags when not in use Unpacking The serverboard is shipped in antistatic packaging to avoid static damage When unpacking the board make sure the person handling it is static protected 5 1 SUPERSERVER 6027R TRF USER S MANUAL 5 2 Processor and Heatsink Installation A Warning When handling the processor package avoid placing direct pressure on the label area Always connect the power cord last and always remove it before adding removing or changing any hardware components Make sure that you in stall the processor into the CPU socket before you install the CPU heatsink Important If you buy a CPU separately make sure that you use an Intel certified multi directional heatsink only Make sure to install the system board into the chassis before you install the CPU heatsink When receiving a server board without a processor pre installed make sure that the plastic CPU socket cap is in place and none of the socket pins are bent otherwise contact your retailer immediately Refer to th
15. headers and jumpers Refer to this chapter when adding or removing processors or main memory and when reconfiguring the serverboard SUPERSERVER 6027R TRF USER S MANUAL Chapter 6 Advanced Chassis Setup Refer to Chapter 6 for detailed information on the SC825TS R740LPBP server chassis You should follow the procedures given in this chapter when installing removing or reconfiguring SAS SATA or peripheral drives and when replacing system power supply units and cooling fans Chapter 7 BIOS The BIOS chapter includes an introduction to BIOS and provides detailed information on running the CMOS Setup Utility for the X9DRi F serverboard Appendix A BIOS Error Beep Codes Appendix B Installing Windows Appendix C System Specifications Preface Notes SUPERSERVER 6027R TRF USER S MANUAL Table of Contents Chapter 1 Introduction 1 1 4 2 1 3 1 4 1 5 OIL N EE EEE EE deaveees Serverboard Features Graphics Controller rriste Gee pei eee eee rei vr elements Other Features eene eene nnnnn sese rnnt seen nasse nnns inna Server Chassis Features is aient eerte eri PEORES 1 3 Ich Hard Drive Subsystem POlExpahsiol Slol8s a irte bte rr rd edere Front Control Panel correre av n RERO RR WO Backplafie 3 1 ino crt te treno cree ici ba nas cete Ra Cooling System Advanced Power Management for F Models Only ssssse 1 4 In
16. interrupt button Fin pam header is located on pins 19 and 20 of Pin Definition JF1 Refer to the table on the right for A pin definitions 20 Ground Serial Ports Serial Port Pin Definitions Two COM connections COM1 COM2 aie are located on the motherboard COM1 eee diia diis is located on the Backplane l O panel i Don P ESR COM2 located close to PCI E Slott 2 iii i x provides front access support See the 9 XE g giS table on the right for pin definitions A DTR a n 5 Ground 10 NC NC No connection 5 18 Video Connection A Video VGA port is located next to LAN2 on the I O backplane Refer to the board layout below for the location Universal Serial Bus USB Four Universal Serial Bus ports USB 0 1 USB 2 3 are located on the I O back panel Please note that BP USB 2 3 can also be used for PS2 Keyboard Mouse connections In addition three USB headers located close to the IO Hub provides six front accessible USB connections USB 4 5 USB 8 9 USB 10 11 One Type A connector USB6 also supports front panel USB connection Cables are not included See the tables on the right for pin definitions Ethernet Ports Two Gigabit Ethernet ports LAN1 LAN are located on the I O backplane on the motherboard In addition an IPMI Dedicated LAN is located above USB 0 1 ports on the backplane to provide KVM support for IPMI 2 0 All these ports accept
17. mainboard must be replaced by trained service technicians only The new fuse must be the same or equivalent as the one replaced Contact technical support for details and support 4 2 General Safety Precautions A Follow these rules to ensure general safety Keep the area around the 2022G URF clean and free of clutter e The 6027R TRF weighs approximately 57 Ibs 25 85 kg when fully loaded When lifting the system two people at either end should lift slowly with their feet spread out to distribute the weight Always keep your back straight and lift with your legs Place the chassis top cover and any system components that have been re moved away from the system or on a table so that they won t accidentally be stepped on While working on the system do not wear loose clothing such as neckties and unbuttoned shirt sleeves which can come into contact with electrical circuits or be pulled into a cooling fan 4 2 Chapter 4 System Safety Remove any jewelry or metal objects from your body which are excellent metal 4 3 conductors that can create short circuits and harm you if they come into contact with printed circuit boards or areas where power is present After accessing the inside of the system close the system back up and secure it to the rack unit with the retention screws after ensuring that all connections have been made ESD Precautions A Electrostatic discharge ESD is generated by two object
18. manual at any time and without notice This product including software and documentation is the property of Supermicro and or its licensors and is supplied only under a license Any use or reproduction of this product is not allowed except as expressly permitted by the terms of said license IN NO EVENT WILL SUPERMICRO BE LIABLE FOR DIRECT INDIRECT SPECIAL INCIDENTAL SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OR INABILITY TO USE THIS PRODUCT OR DOCUMENTATION EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES IN PARTICULAR SUPERMICRO SHALL NOT HAVE LIABILITY FOR ANY HARDWARE SOFTWARE OR DATA STORED OR USED WITH THE PRODUCT INCLUDING THE COSTS OF REPAIRING REPLACING INTEGRATING INSTALLING OR RECOVERING SUCH HARDWARE SOFTWARE OR DATA Any disputes arising between manufacturer and customer shall be governed by the laws of Santa Clara County in the State of California USA The State of California County of Santa Clara shall be the exclusive venue for the resolution of any such disputes Super Micro s total liability for all claims will not exceed the price paid for the hardware product FCC Statement This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can rad
19. of the chassis can support a AOC PG i2 add on card to provide two additional Gb LAN ports Alternately this slot can instead support either a UIO card one PCI E x16 card or four SAS SATA drives with an optional UlIO SAS card See our web site for details http www supermicro com products nfo UIO cfm See section 5 6 for further details Front Control Panel The control panel on the SUPERSERVER 6027R TRF provides you with system monitoring and control LEDs indicate system power HDD activity network activity System overheat and power supply failure A main power button and a system reset button are also included In addition two USB ports have been incorporated into the control panel to provide front side USB access 1 3 SUPERSERVER 6027R TRF USER S MANUAL I O Backplane The SC825TS R740LPBP is an ATX form factor chassis designed to be used in a 2U rackmount configuration The I O backplane provides four standard size add on card slots one COM port a VGA port two USB 2 0 ports PS 2 mouse and keyboard ports a dedicated IPMI LAN port and two gigabit Ethernet ports Cooling System The SC825TS R740LPBP chassis has an innovative cooling design that includes three 8 cm hot plug system cooling fans located in the middle section of the chassis An air shroud channels the airflow from the system fans to efficiently cool the processor area of the system The power supply module also includes a cooling fan 1 4 Advanced Power M
20. 00 L x 13 00 W 304 80 mm x 330 20 mm Chassis SC825TS R740LPBP 2U rackmount Dimensions WxHxD 16 8 x 3 5 x 25 5 in 427 x 89 x 648 mm Weight Gross Bare Bone 57 Ibs 25 9 kg System Cooling Three 8 cm system cooling fans System Input Requirements AC Input Voltage 100 230V AC auto range Rated Input Current 9A 4A Rated Input Frequency 50 to 60 Hz Platinum 90 Platinum Level Power Supply Rated Output Power 740 Watt Part PWS 741P 1R Rated Output Voltages 12V 12A 5Vsb 5A Operating Environment Operating Temperature 0 to 60 C 32 to 140 F Non operating Temperature 40 to 70 C 40 to 158 F Operating Relative Humidity 20 to 95 non condensing Non operating Relative Humidity 5 to 95 non condensing B 2 Appendix B System Specifications Regulatory Compliance Electromagnetic Emissions FCC Class A EN 55022 Class A EN 61000 3 2 3 3 CISPR 22 Class A Electromagnetic Immunity EN 55024 CISPR 24 EN 61000 4 2 EN 61000 4 3 EN 61000 4 4 EN 61000 4 5 EN 61000 4 6 EN 61000 4 8 EN 61000 4 11 Safety CSA EN IEC UL 60950 1 Compliant UL or CSA Listed USA and Canada CE Marking Europe California Best Management Practices Regulations for Perchlorate Materials This Perchlorate warning applies only to products containing CR Manganese Dioxide Lithium coin cells Perchlorate Material special handling may apply See www dtsc ca gov hazardouswaste perchlor
21. 00390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl Technical Support rma supermicro nl Customer Support Asia Pacific Address Super Micro Computer Inc 4F No 232 1 Liancheng Rd Chung Ho 235 Taipei County Taiwan R O C Tel 886 2 8226 3990 Fax 886 2 8226 3991 Web Site www supermicro com tw Technical Support Email support supermicro com tw Tel 886 2 8226 5990 1 6 Chapter 2 Server Installation Chapter 2 Server Installation 2 1 Overview This chapter provides a quick setup checklist to get your SUPERSERVER 6027R TRF up and running Following these steps in the order given should enable you to have the system operational within a minimum amount of time This quick setup assumes that your system has come to you with the processors and memory preinstalled If your system is not already fully integrated with a serverboard processors system memory etc please turn to the chapter or section noted in each step for details on installing specific components 2 2 Unpacking the System You should inspect the box the SUPERSERVER 6027R TRF was shipped in and note if it was damaged in any way If the server itself shows damage you should file a damage claim with the carrier who delivered it Decide on a suitable location for the rack unit that will hold the SUPERSERVER 6027R TRF It should be situated in a clean dust free area that is well ventilated Avoid area
22. 1 2 motherboard aem Pins Definition 1 through 4 Ground 5 through 8 12V Required Connections 5 16 PW_ON Connector The Power Button connection is located on pins 1 and 2 of JF1 Momentarily contacting both pins will power on off the system This button can also be configured to function as a suspend button with a setting in the BIOS See Chapter 5 To turn off the power when the system is in suspend mode press the button for 4 seconds or longer Refer to the table on the right for pin definitions Reset Connector The reset connector is located on pins 3 and 4 of JF1 and attaches to the reset switch on the computer chassis See the table on the right for pin definitions Power Fail LED The Power Fail LED connection is located on pins 5 and 6 of JF1 Refer to the table on the right for pin definitions Overheat Fan Fail LED OH Connect an LED to the OH connection on pins 7 and 8 of JF1 to provide advanced warning of chassis overheating or fan failure Refer to the table on the right for pin definitions and status indicators NIC2 LAN2 LED The LED connections for LAN2 are on pins 9 and 10 of JF1 Attach LAN LED cables to display network activity See the table on the right for pin definitions Chapter 5 Advanced Serverboard Setup Power Button Pin Definitions JF1 Pin Definition 1 PW_ON 2 Ground Reset Button Pin Definitions JF1 Pin D
23. 740LPBP chassis For component installation follow the steps in the order given to eliminate the most common problems encountered If some steps are unnecessary skip ahead to the step that follows Tools Required The only tool you will need to install components and perform maintenance is a Philips screwdriver 6 1 Static Sensitive Devices Electrostatic discharge ESD can damage electronic components To prevent damage to any printed circuit boards PCBs it is important to handle them very carefully The following measures are generally sufficient to protect your equipment from ESD damage Precautions e Use a grounded wrist strap designed to prevent static discharge Touch a grounded metal object before removing any board from its antistatic bag Handle a board by its edges only do not touch its components peripheral chips memory modules or gold contacts When handling chips or modules avoid touching their pins Put the serverboard add on cards and peripherals back into their antistatic bags when not in use For grounding purposes make sure your computer chassis provides excellent conductivity between the power supply the case the mounting fasteners and the serverboard Unpacking The serverboard is shipped in antistatic packaging to avoid static damage When unpacking the board make sure the person handling it is static protected 6 1 SUPERSERVER 6027R TRF USER S MANUAL Figure 6 1 Front and Re
24. CPU or the heatsink be removed AN However if you do need to uninstall the heatsink please follow the instruc tions below to uninstall the heatsink to prevent damage done to the CPU or the CPU socket 1 Unscrew the heatsink screws from the motherboard in the sequence as shown in the illustration below 2 Gently wriggle the heatsink to loosen it from the CPU Do not use excessive force when wriggling the heatsink 3 Once the CPU is loosened remove the CPU from the CPU socket 4 Remove the used thermal grease and clean the surface of the CPU and the heatsink Reapply the proper amount of thermal grease on the surface before reinstalling the CPU and the heatsink Loosen screws in sequence as Screw 1 SUPERSERVER 6027R TRF USER S MANUAL 5 8 Connecting Cables Now that the processors are installed the next step is to connect the cables to the serverboard These include the data ribbon cables for the peripherals and control panel and the power cables Connecting Data Cables The cables used to transfer data from the peripheral devices have been carefully routed in preconfigured systems to prevent them from blocking the flow of cooling air that moves through the system from front to back If you need to disconnect any of these cables you should take care to reroute them as they were originally after reconnecting them make sure the red wires connect to the pin 1 locations If you are configuring the system keep
25. Control Panel Buttons There are two buttons located on the front of the chassis a reset button and a power on off button RESET Reset Use the reset button to reboot the system Power This is the main power button which is used to apply or turn off the main system power Turning off system power with this button removes the main power but keeps standby power supplied to the system 3 1 SUPERSERVER 6027R TRF USER S MANUAL 3 3 Control Panel LEDs The control panel located on the front of the chassis has several LEDs These LEDs provide you with critical information related to different parts of the system This section explains what each LED indicates when illuminated and any corrective action you may need to take ly Wi Power Fail Indicates a power supply module has failed The second power supply module will take the load and keep the system running but the failed module will need to be replaced Refer to Chapter 6 for details on replacing the power supply This LED should be off when the system is operating normally fa Overheat Fan Fail When this LED flashes it indicates a fan failure When on continuously it indicates an overheat condition which may be caused by cables obstructing the airflow in the system or the ambient room temperature being too warm Check the routing of the cables and make sure all fans are present and operating normally You should also check to make sure that the chassis covers
26. P1 C1 P1 D1 P2 E1 P2 F1 P2 G1 P2 H1 2 CPUs amp CPU1 CPU2 10 16 DIMMs P1 A1 P1 B1 P1 C1 P1 D1 P2 E1 P2 F1 P2 G1 P2 H1 Any memory pairs in P1 P2 DIMM slots 2 CPUs amp CPU1 CPU2 16 DIMMs P1 A1 P1 B1 P1 C1 P1 D1 P2 E1 P2 F1 P2 G1 P2 H1 P1 A2 P1 B2 P1 C2 P1 D2 P2 E2 P2 F2 P2 G2 P2 H2 5 11 SUPERSERVER 6027R TRF USER S MANUAL DIMM Module Population Configuration For memory to work properly follow the tables below for memory installation RDIMM Support POR on the E5 2600 Series Processor Platform DIMM DIMMs RDIMM Type POR Speeds in MHz Ranks per DIMM Slots per Populated RDIMM Reg Any Channel per DDR Registered Combination Channel 1 1 Reg ECC DDR3 800 1066 1333 1600 SR DR or QR 2 1 Reg ECC DDR3 800 1066 1333 1600 SR DR or QR 2 2 Reg ECC DDR3 800 1066 1333 1600 Mixing SR DR QR Population Rules 1 Any combination of x4 and x8 RDIMMs with 1 Gb or 2 Gb DRAM Density are supported 2 Populate DIMMs starting with DIMM A1 3 When mixing QR with SR or DR on the same DDR channel put the QR in DIMMAt first Note For the memory modules to work properly please install DIMM modules in pairs with an even number of DIMMs installed Note All channels in a system will run at the fastest common frequency Possible System Memory Allocation amp Availability System Device Size Physical Memory Available 4 GB Total System Memory Fi
27. RJ45 type cables Please refer to the LED Indicator Section for LAN LED information Chapter 5 Advanced Serverboard Setup FP USB 4 5 8 9 10 11 USB 6 Pin Definitions USB 4 8 10 6 7 USB 5 9 11 Pin Definition Pin Definition 1 5V 1 5V 2 PO 2 PO 3 PO 3 PO 4 Ground 4 Ground 5 NC 5 Key NC No connection Backplane USB 0 1 2 3 Pin Definitions Pin Definition 1 5V 2 Po 3 Po 4 Ground 5 NA LAN Ports Pin Definition LAN 1 2 Pin Definition Pin Definition 1 P2V5SB 10 SGND 2 TDO 11 Act LED 3 TDO 12 P3V3SB 4 TD1 13 Link 100 LED Yellow 3V3SB 5 TDI 14 Link 1000 LED Yellow 3V3SB 6 TD2 15 Ground 3 TD2 16 Ground 8 TD3 17 Ground 9 TD3 18 Ground NC No Connection 5 19 SUPERSERVER 6027R TRF USER S MANUAL Fan Headers Fan Header Pin Definitions This motherboard has eight system CPU fan headers Fan 1 Fan 6 Fan pine even A Fan B on the motherboard All 4 eus these 4 pin fans headers are backward 2 ud compatible with the traditional 3 pin 3 Tachometer fans However fan speed control is 4 PWR Modulation available for 4 pin fans only The fan speeds are controlled by Thermal Management via Hardware Monitoring in the Advanced Setting in the BIOS See Chapter 4 for more details See the table on the right for pin definitions Chassis Intrusion Chassis Intrusion
28. SUPER SUPERSERVER 6027R TRF CUUUUUUUUUUUUUU UUUUUUUUUUUUUUU YES cn J oo UJ 20600002000000 goonoeocococooG fa ES ete nonna ODO 55606 000600660860086 IE 1980000000000 ODOODOOODOOOOOO00 o DOOOOOOO0OOO000 o DOODDODOOOOODOO0 DOOOOOOOOOOOQODOO v9 KOOOOOOOOOOOOOOO0 IDOOOOOOOOOOOOOO9 DOOOOOOOQOOOOOOO9 OOODOOOODOOODUOOs0 ee i KOOODOOOODOOO0000 9 DOODOOOCOOOOOOOO0039 OOOODOOOOOCOOOODOO0 OOODOODOOCOOOOOO o KODCOODOOOOQOOOCQOO9 OODCODCOOOOOOOO 000 9 DOODOOOOQOODOQOCO ODODOOOOOQOOOQDOOCOs9 L i l i LL LUE J USER S MANUAL Revision 1 0a The information in this User s Manual has been carefully reviewed and is believed to be accurate The vendor assumes no responsibility for any inaccuracies that may be contained in this document makes no commitment to update or to keep current the information in this manual or to notify any person or organization of the updates Please Note For the most up to date version of this manual please see our web site at www supermicro com Super Micro Computer Inc Supermicro reserves the right to make changes to the product described in this
29. SXB1 Configuration BIOS setting select the 2x8 option Then save the BIOS setting changes and reboot the system 5 13 SUPERSERVER 6027R TRF USER S MANUAL 5 7 Serverboard Details OvivS cvivsi vvIVST Figure 5 4 X9DRi F Serverboard Layout not drawn to scale Tad oom ois Twa E 8X0 3 Dd 1OTS Indo cay dey VGA LAND LANI USB23 USB Co O wwe C CO b dk 7HAWGZd THAIN Zd ZINNIA Zd TONNO zd Wa Td Ly TN oooo ooom 000m Daal oo00 ae TWO Td und f oo00000000000 00000000000N A locom 8 2 o TERG EE i F S F i giel SLES E E x x 2g 2 zz j E 8 RENE E E d l L E E d a4 P E amp 1 SUPER XODR3 F 1i bes A Rev 1 10 io oe e i Wo lollo H nc ii a 7 SB Q0 dcs A 3 ji 2606 E ii ARE PRIE JE Xon o H Notes e See Chapter 2 for detailed panel connections on information on jumpers I O ports and JF1 front indicates the location of Pin 1 Jumpers LED Indicators not indicated are for testing only Use only the correct type of onboard CMOS battery as specified by the manufac turer Do not install the onboard battery upside down t
30. Scrubbing is a process that allows the CPU to correct correctable memory errors detected on a memory module and send the correction to the requestor the original source When this item is set to Enabled the IO hub will read and write back one cache line every 16K cycles if there is no delay caused by internal processing By using this method roughly 64 GB of memory behind the IO hub will be scrubbed every day The options are Enabled and Disabled 7 11 SUPERSERVER 6027R TRF USER S MANUAL Demand Scrub Demand Scrubbing is a process that allows the CPU to correct correctable memory errors found on a memory module When the CPU or I O issues a demand read command and the read data from memory turns out to be a correctable error the error is corrected and sent to the requestor the original source Memory is updated as well Select Enabled to use Demand Scrubbing for ECC memory correction The options are Enabled and Disabled Data Scrambling Select Enabled to enable data scrubbing and ensure data security and integrity The options are Disabled and Enabled DRAM RAPL RAPL which stands for Running Average Power Limit is a feature that provides mechanisms to enforce power consumption limits on supported processors The options are Mode 0 MODE1 and Disabled Device Tagging Select Enabled to support device tagging The options are Disabled and Enabled Thermal Throttling Throttling improves reliability and reduces power consumpti
31. U installed in Socket 1 64 bit This item indicates if the CPU installed in Socket 1 supports 64 bit technology Hyper threading Select Enabled to support Intel Hyper threading Technology to enhance CPU performance The options are Enabled and Disabled Active Processor Cores Set to Enabled to use a processor s Second Core and beyond Please refer to Intel s web site for more information The options are All 1 2 and 4 Limit CPUID Maximum This feature allows the user to set the maximum CPU ID value Enable this function to boot the legacy operating systems that cannot support processors with extended CPUID functions The options are Enabled and Disabled for the Windows OS Execute Disable Bit Capability Available if supported by the OS amp the CPU Set to Enabled to enable the Execute Disable Bit which will allow the processor to designate areas in the system memory where an application code can execute and where it cannot thus preventing a worm or a virus from flooding illegal codes to overwhelm the processor or damage the system during an attack The default is Enabled Refer to Intel and Microsoft Web Sites for more information 74 Chapter 7 BIOS Hardware Prefetcher Available when supported by the CPU If set to Enabled the hardware prefetcher will prefetch streams of data and instructions from the main memory to the L2 cache to improve CPU performance The options are Disabled and Enabled Adjacent C
32. USB device The options are Disabled and Enabled EHCI Hand off Select Enabled to enable support for operating systems that do not support Enhanced Host Controller Interface EHCI hand off When enabled EHCI ownership change will be claimed by the EHCI driver The options are Disabled and Enabled gt SATA Configuration When this submenu is slected the AMI BIOS automatically detects the presence of IDE or SATA devices and displays the following items SATA Port0 SATA Port5 The AMI BIOS displays the status of each SATA port as detected by the BIOS SATA Mode Use this feature to configure SATA mode for a selected SATA port The options are Disabled IDE Mode AHCI Mode and RAID Mode The following are displayed depending on your selection IDE Mode The following items are displayed when IDE Mode is selected 7 13 SUPERSERVER 6027R TRF USER S MANUAL Serial ATA SATA Controller 0 1 Use this feature to activate or dactivate the SATA controller and set the com patibility mode The options for Controller 0 are Enhanced and Compatible The default setting for SATA Controller 1 is Enhanced AHCI Mode The following items are displayed when the AHCI Mode is selected Aggressive Link Power Management Select Enabled to enable Aggressive Link Power Management to support Cougar Point BO stepping and beyond The options are Enabled and Dis abled Port 0 Port 5 Hot Plug Select Enabled to enable hot plug support for
33. ache Line Prefetch Available when supported by the CPU If this feature is set to Disabled The CPU prefetches the cache line for 64 bytes If this feature is set to Enabled the CPU fetches both cache lines for 128 bytes as comprised The options are Disabled and Enabled DCU Streamer Prefetcher Available when supported by the CPU Select Enabled to support Data Cache Unite DCU prefetch to speed up data accessing and processing in the DCU to enhance CPU performance The options are Disabled and Enabled DCU IP Prefetcher Select Enabled for DCU Data Cache Unit IP Prefetcher support which will prefetch IP addresses to improve network connectivity and system performance The options are Enabled and Disabled Intel Virtualization Technology Available when supported by the CPU Select Enabled to support Intel Virtualization Technology which will allow one platform to run multiple operating systems and applications in independent partitions creating multiple virtual systems in one physical computer The options are Enabled and Disabled Note If there is any change to this setting you will need to power off and restart the system for the change to take effect Please refer to Intel s website for detailed information Clock Spread Spectrum Select Enabled to enable Clock Spectrum support which will allow the BIOS to monitor and attempt to reduce the level of Electromagnetic Interference caused by the components whenever neede
34. ack Rails Outer rails attach to the rack and hold the chassis in place The outer rails for the SC825 chassis extend between 30 inches and 33 inches Installing the Outer Rails to the Rack 1 Secure the back end of the outer rail to the rack using the screws provided 2 Press the button where the two outer rails are joined to retract the smaller outer rail 3 Hang the hooks of the rails onto the rack holes and if desired use screws to secure the front of the outer rail onto the rack 4 Repeat steps 1 3 for the remaining outer rail 2 6 Chapter 2 Server Installation Figure 2 3 Installing the Rack Rails Installing the Chassis into a Rack Extend the outer rails as illustrated above Align the inner rails of the chassis with the outer rails on the rack Slide the inner rails into the outer rails keeping the pressure even on both sides When the chassis has been pushed completely into the rack it should click into the locked position Optional screws may be used to secure the to hold the front of the chassis to the rack 2 7 SUPERSERVER 6027R TRF USER S MANUAL 2 5 Checking the Serverboard Setup After you install the 6027R TRF in the rack you will need to open the unit to make sure the serverboard is properly installed and all the connections have been made Accessing the inside of the System T First grasp the two handles on either side and pull the uni
35. anagement for F Models Only Intel Intelligent Power Node Manager NM The Intel Intelligent Power Node Manager IPNM provides your system with real time thermal control and power management for maximum energy efficiency Although IPNM Specification Version 1 5 is supported by the BMC Baseboard Management Controller your system must also have IPNM compatible Manageability Engine ME firmware installed to use this feature Manageability Engine ME The Manageability Engine which is an ARC controller embedded in the IOH I O Hub provides Server Platform Services SPS to your system The services provided by SPS are different from those proveded by the ME on client platforms 1 4 Chapter 1 Introduction Figure 1 1 Intel PCH C602 C606 Chipset System Block Diagram Note This is a general block diagram Please see Chapter 5 for details PCI E X16 G3 PCI E X16 G3 PCI E X16 G3 PCI E X8 G3 PCI E X8 G3 PCI E X8 G3 PCI E X4 G3 Ed a e E a o ay SUPERSERVER 6027R TRF USER S MANUAL 1 5 Contacting Supermicro Headquarters Address Super Micro Computer Inc 980 Rock Ave San Jose CA 95131 U S A Tel 1 408 503 8000 Fax 1 408 503 8008 Email marketing supermicro com General Information support supermicro com Technical Support Web Site www supermicro com Europe Address Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 64
36. ar Chassis Views 3 5 Drive Bays 2 USB Ports 2 COM Port Slim DVD ROM Drive Control Panel CUUUUUNUUUUUUUU JUOGUUUUUUU ILU ES ojo UUUUUU 500 41A DOS coo o 2283865990000 poe Se naana estt BO0050000000000 000002000200200 a LZ EE atatatatateratatatelatat q CEEEDECDODCOOUD e DOOOOOOOOOOOOOO ao x D 20 OODOOOOUOOOOQOO9 DODOOOOOUOOOOOOO o E q H Ld D IOOOOOOOOOOOOOOO 9 COCOOOOOOCODODO E E L 1 L Jd 1 ee es SATA Drives 8 System Reset Main Power IPMI LAN ica in Port 4 Standard Size PCI Slots Um jE PS 4 TEn Je uo U U T aaa OORSSB E8000 olei 2258 AD m ce CIO Stale oop lo 5 5 D 5 N
37. are installed Finally verify that the heatsinks are installed properly see Chapter 5 This LED will remain flashing or on as long as the indicated condition exists E NIC1 Indicates network activity on the LAN1 port when flashing ES NIC2 Indicates network activity on the LAN2 port when flashing 3 2 Chapter 3 System Interface D HDD On the SUPERSERVER 6027R TRF this LED indicates hard drive and or DVD ROM drive activity when flashing c 4 ats Power Indicates power is being supplied to the system s power supply units This LED should normally be illuminated when the system is operating 3 4 Drive Carrier LEDs Each drive carrier has two LEDs SATA Drives Green When illuminated the green LED on the SATA drive carrier indicates drive activity A connection to the SATA backplane enables this LED to blink on and off when that particular drive is being accessed Please refer to Chapter 6 for instructions on replacing failed SATA drives Red When this LED flashes it indicates the drive is rebuilding When solid on it indicates a SATA drive failure If a drive fails you should be notified by your System management software Please refer to Chapter 6 for instructions on replacing failed drives SAS Drives Green When illuminated the green LED on the drive carrier indicates the SAS drive is powered on If this LED is not lit it means no power is being provided for the drive Please refer
38. ate B 3 SUPERSERVER 6027R TRF USER S MANUAL continued from front The products sold by Supermicro are not intended for and will not be used in life support systems medical equipment nuclear facilities or systems aircraft aircraft devices aircraft emergency communication devices or other critical systems whose failure to perform be reasonably expected to result in significant injury or loss of life or catastrophic property damage Accordingly Supermicro disclaims any and all liability and should buyer use or sell such products for use in such ultra hazardous applications it does so entirely at its own risk Furthermore buyer agrees to fully indemnify defend and hold Supermicro harmless for and against any and all claims demands actions litigation and proceedings of any kind arising out of or related to such ultra hazardous use or sale B 4
39. d The options are Disabled and Enabled gt CPU Power Management Configuration This submenu allows the user to configure the following CPU Power Management settings 7 5 SUPERSERVER 6027R TRF USER S MANUAL Power Technology Select Energy Efficiency to support power saving mode Select Custom to customize system power settings Select Disabled to disable power saving settings The options are Disable Energy Efficient and Custom If Custom is selected the following options become available EIST EIST Enhanced Intel SpeedStep Technology allows the system to automatically adjust processor voltage and core frequency in an effort to reduce power consumption and heat dissipation Please refer to Intel s web site for detailed information The options are Disabled and Enabled Turbo Mode This feature allows processor cores to run faster than marked frequency in specific conditions The options are Disabled and Enabled P STATE Coordination This feature selects the type of coordination for the P State of the processor P State is a processor operational state that reduces the processor s voltage and frequency This makes the processor more energy effiicient resulting in further gains The options are HW_ALL SW_ALL and SW ANY CPU C3 Report CPU C6 Report CPU C7 Report This BIOS feature enables or disables C3 C6 and C7 reporting to the operating system The options for C3 and C7 are Disabled and Enabled The options for C6 are Di
40. d be mounted into a rack so that the amount of airflow required for safe operation is not compromised Mechanical Loading Equipment should be mounted into a rack so that a hazardous condition does not arise due to uneven mechanical loading Circuit Overloading Consideration should be given to the connection of the equipment to the power supply circuitry and the effect that any possible overloading of circuits might have on overcurrent protection and power supply wiring Appropriate consideration of equipment nameplate ratings should be used when addressing this concern Reliable Ground A reliable ground must be maintained at all times To ensure this the rack itself should be grounded Particular attention should be given to power supply connections other than the direct connections to the branch circuit i e the use of power strips etc 2 3 SUPERSERVER 6027R TRF USER S MANUAL 2 4 Installing the System into a Rack This section provides information on installing the SC825 chassis into a rack unit with the quick release rails provided There are a variety of rack units on the market which may mean the assembly procedure will differ slightly You should also refer to the installation instructions that came with the rack unit you are using Note This rail will fit a rack between 26 and 33 5 deep Separating the Sections of the Rack Rails The chassis package includes two rail assemblies in the rack mounting kit Each a
41. damage your CPU Instead open the load plate again and double check that the CPU is aligned properly Warning You can only install the CPU inside the socket in one direction 5 4 Chapter 5 Advanced Serverboard Setup 7 With the CPU inside the socket inspect the four corners of the CPU to make sure that the CPU is properly installed 8 Close the load plate with the CPU inside the socket Lock the lever labeled Close 1st first then lock the lever labeled Open 1st second Use your thumb to gently push the load levers down to the lever locks Gently close the load plate Push down and lock the level labeled Close 1st ge Push down and lock the lever Lever Lock 5 5 SUPERSERVER 6027R TRF USER S MANUAL Installing a Passive CPU Heatsink 1 Do not apply any thermal grease to the heatsink or the CPU die the required amount has already been applied 2 Place the heatsink on top of the CPU so that the four mounting holes are aligned with those on the Motherboard s and the Heatsink Bracket underneath 3 Screw in two diagonal screws i e the 1 and the 2 screws until just snug do not over tighten the screws to avoid possible damage to the CPU 4 Finish the installation by fully tightening all four screws ne d 7 LS z gt aN Motherboard 5 6 Chapter 5 Advanced Serverboard Setup Removing the Heatsink Warning We do not recommend that the
42. e JPL1 enables or disables the GLAN Port1 GLAN Port2 on the motherboard See the table on the right for jumper settings The default setting is Enabled 23 Disables LAN Enable Disable Jumper Settings JPL1 Jumper Setting Definition 1 2 Enabled default 5 24 Watch Dog Enable Disable Watch Dog JWD is a system monitor that will reboot the system when a software application hangs Close Pins 1 2 to reset the system if an application hangs Close Pins 2 3 to generate a non maskable interrupt signal for the application that hangs See the table on the right for jumper settings Watch Dog must also be enabled in the BIOS VGA Enable Disable Jumper JPG1 allows the user to enable the onboard VGA connector The default setting is 1 2 to enable the connection See the table on the right for jumper settings BMC Enable Jumper JPB1 allows you to enable the embedded WPCM 450 BMC Baseboard Management Controller to provide IPMI 2 0 KVM support on the motherboard See the table on the right for jumper settings Manufacturer Mode Select Close this jumper JPME1 to bypass SPI flash security and force the system to use the Manufacturer mode which will allow the user to flash the system firmware from a host server to modify system settings See the table on the right for jumper settings Write_Protect Enable Close pins 1 2 of Jumper JWP1 to enable Write Protect support for system security and data
43. e Supermicro website for updates on CPU support Installing the LGA2011 Processor 1 There are two load levers on the LGA2011 socket To open the socket cover first press and release the load lever labeled Open 1st Press down on Load Lever labeled Open 1st 5 2 Chapter 5 Advanced Serverboard Setup 2 Press the second load lever labeled Close 1st to release the load plate that covers the CPU socket from its locking position Press down on Load the Pull lever away Lever labeled Close 1st from the socket 3 With the lever labeled Close 1st fully retracted gently push down on the Open 1st lever to open the load plate Lift the load plate to open it completely Gently push down to pop the load plate open 4 Using your thumb and the index finger remove the WARNING plastic cap from the socket SUPERSERVER 6027R TRF USER S MANUAL 5 Use your thumb and index finger to hold the CPU on its edges Align the CPU keys which are semi circle cutouts against the socket keys 6 Once they are aligned carefully lower the CPU straight down into the socket Do not drop the CPU on the socket Do not move the CPU horizontally or vertically Do not rub the CPU against the surface or against any pins of the socket to avoid damaging the CPU or the socket Make sure that it is properly inserted into the CPU socket before closing the load plate If it doesn t close properly do not force it as it may
44. e the handle to pull it straight out with the rounded handle Installing a New Power Supply 1 Replace the failed hot swap unit with another identical power supply unit 2 Push the new power supply unit into the power bay until you hear a click 3 Secure the locking tab on the unit 4 Finish by plugging the AC power cord back into the unit 6 8 Chapter 7 BIOS 7 1 Chapter 7 BIOS Introduction This chapter describes the AMI BIOS Setup Utility for the SUPERSERVER 6027R TRF The AMI ROM BIOS is stored in a Flash EEPROM and can be easily updated This chapter describes the basic navigation of the AMI BIOS Setup Utility setup screens Starting the Setup Utility To enter the BIOS Setup Utility hit the lt Delete gt key while the system is booting up In most cases the lt Delete gt key is used to invoke the BIOS setup screen There are a few cases when other keys are used such as lt F1 gt lt F2 gt etc Each main BIOS menu option is described in this manual The Main BIOS screen has two main frames The left frame displays all the options that can be configured Grayed out options cannot be configured The right frame displays the key legend Above the key legend is an area reserved for a text message When an option is selected in the left frame it is highlighted in white Often a text message will accompany it Note that BIOS has default text messages built in We retain the option to include omit or c
45. e top cover and at the same time push the cover away from you until it stops You can then lift the top cover from the chassis to gain full access to the inside of the server 6 7 SUPERSERVER 6027R TRF USER S MANUAL 6 5 Power Supply The SUPERSERVER 6027R TRF has a 740 Watt redundant power supply consisting of two power modules Each power supply module has an auto switching capability which enables it to automatically sense and operate at a 100V 240V input voltage Power Supply Failure If either of the two power supply modules fail the other module will take the full load and allow the system to continue operation without interruption The PWR Fail LED will illuminate and remain on until the failed unit has been replaced Replacement units can be ordered directly from Supermicro see contact information in the Preface The power supply units have a hot swap capability meaning you can replace the failed unit without powering down the system Removing Replacing the Power Supply You do not need to shut down the system to replace a power supply unit The backup power supply module will keep the system up and running while you replace the failed hot swap unit Replace with the same model see part number in the Appendix which can be ordered directly from Supermicro Removing the Power Supply 1 First unplug the AC power cord from the failed power supply module 2 Depress the locking tab on the power supply module 3 Us
46. efinition 3 Reset 4 Ground PWR Fail LED Pin Definitions JF1 Pin Definition 5 3 3V 6 PWR Supply Fail OH Fan Fail LED Pin Definitions OH Fan Fail JF1 LED Status Pin Definition State Indication 7 Vcc Solid Overheat 8 Control Blinking Fan fail NIC2 LED Pin Definitions JF1 Pin Definition 9 Vcc 10 Ground 5 17 SUPERSERVER 6027R TRF USER S MANUAL NIC1 LAN1 LED NIC1 LED Pin Definitions JF1 Pin Definition The LED connections for LAN1 are on pins 11 and 12 of JF1 Attach LAN LED cables to display network activity See 11 Voc the table on the right for pin definitions 12 Ground HDD LED HDD LED The HDD LED connection is located Pin ey on pins 13 and 14 of JF1 Attach the hard drive LED cable here to display disk activity for any hard drives on the system including SAS Serial ATA and IDE See the table on the right for pin definitions Pin Definition 13 Vec 14 HD Active Power On LED Power LED Pin Definitions JF1 Pin Definition The Power On LED connector is located on pins 15 and 16 of JF1 This connection is used to provide LED Mir i 15 5V Stby indication of power being supplied to TuS ontroi the system See the table on the right for pin definitions NMI Button NMI Button The non maskable
47. eleven USB 2 0 ports 4x rear 6x header 1x type A PS 2 mouse and keyboard ports two gigabit Ethernet ports and one dedicated IPMI LAN port Note 1 For more information on IPMI configuration please refer to the IPMI User s Guide posted on our website at http www supermicro com support manuals Graphics Controller The X9DRi F features an integrated Nuvoton WP450R BMC Base board Controller BMC chip which also acts as a video controller 1 2 Chapter 1 Introduction Other Features Other onboard features that promote system health include onboard voltage monitors auto switching voltage regulators chassis and CPU overheat sensors power management AC power loss recovery virus protection and BIOS rescue 1 3 Server Chassis Features The 6027R TRF is built upon the SC825TS R740LPBP chassis Details on the chassis and on servicing procedures can be found in Chapter 6 The following is a general outline of the main features of the chassis System Power The SC825TS R740LPBP features a redundant 740 Watt power supply consisting of two power modules The system does not need to be shut down when replacing or removing a single power supply module Hard Drive Subsystem The SC825TS R740LPBP chassis was designed to support eight hot swap SATA or SAS hard drives Note A SAS UIO card must be installed to support SAS drives not included with system PCI Expansion Slots A riser card RSC R2UU UA3E8 on the left side
48. es at right for more information Onboard Power LED An Onboard Power LED is located at LE1 on the motherboard When this LED is on the system is on Be sure to turn off the system and unplug the power cord before removing or installing components See the tables at right for more information SUPERSERVER 6027R TRF USER S MANUAL Link Speed LED Ld Ld LED Rear View when facing the rear side of the chassis LAN Activity Indicator Right LED Settings Color Status Definition Off No Connections Yellow Flashing Active LAN Link Speed Indicator Left LED Settings Color Definition Off No Connection or 10 Mbps Green 100 Mbps Amber 1 Gbps IPMI LAN Link Speed LED Activity LED E IPMI LAN Link Speed LED Left amp Connection Activity LED Right LED Color State Definition Off Off No Connection Activity Amber Blinking Active Speed Green Solid 100 Mbps Onboard PWR LED Indicator LED Settings LE1 LED Color Definition Off System Off PWR cable not connected Green System On Green ACPI S1 State Flashing Quickly 5 26 Chapter 5 Advanced Serverboard Setup BMC Heartbeat LED BMC Heartbeat LED A BMC Heartbeat LED is located at Seus DM1 on the motherboard When DM1 iii ai nee is blinking BMC functions normally See Blinking Dod the table at right for more information
49. gure 5 1 Front Control Panel Header Pins JF1 20 19 5 4 I O Ports The I O ports are color coded in conformance with the PC 99 specification See Figure 5 2 below for the colors and locations of the various l O ports Figure 5 2 Rear Panel I O Ports oojillil e oL oL Rear I O Ports 1 COM Port 1 Turquoise 6 Back Panel USB Port 3 2 Back Panel USB Port 0 7 PS2 Keyboard or Mouse Optional 3 Back Panel USB Port 1 8 Gigabit LAN 1 4 IPMI_Dedicated LAN 9 Gigabit LAN 2 5 Back Panel USB Port 2 10 Back Panel VGA Blue 5 9 SUPERSERVER 6027R TRF USER S MANUAL 5 5 Installing Memory CAUTION Exercise extreme care when installing or removing DIMM modules to prevent any possible damage Memory Support The X9DRi F supports up to 512 GB of DDR3 1600 1333 1066 800 MHz speed registered ECC 1GB 2GB 4GB 8GB 16GB and 32GB size SDRAM in sixteen 16 DIMM slots See the following table for memory installation Memory speed support is dependent on the type of CPU used on the board Installing Memory Modules 1 Insert the desired number of DIMMs into the memory slots starting with DIMM 1A For best memory performance please install memory modules of the same type and same speed on the memory slots as indicated on the tables below 2 Insert each DIMM module vertically into its slot Pay attention to the notc
50. h along the bottom of the module to avoid installing incorrectly see Figure 5 3 3 Gently press down on the DIMM module until it snaps into place in the slot Repeat for all modules To Install Insert module vertically and press down until it snaps into place Pay attention to the align ment notch at the bottom To Remove Use your thumbs to gen tly push the release tabs near both ends of the module This should release it from the slot Figure 5 3 Installing DIMM into Slot N Note Notch should align with the receptive key point on the slot Release Tab Release Tab 5 10 Chapter 5 Advanced Serverboard Setup Processors and their Corresponding Memory Modules CPU Corresponding DIMM Modules CPU1 P1 A1 P1 B1 P1 C1 P1 D1 P1 A2 P1 B2 P1 C2 P1 D2 CPU2 P2 E1 P2 F1 P2 G1 P2 H1 P2 E2 P2 F2 P2 G2 P2 H2 Processor and Memory Module Population Number of CPU and Memory Population Configuration Table CPUs DIMMs For memory to work proper please install DIMMs in pairs 1 CPU amp CPU1 2 DIMMs P1 A1 P1 B1 1CPU amp CPU 4 DIMMs P1 A1 P1 B1 P1 C1 P1 D1 1CPU amp CPU1 5 8 DIMMs P1 A1 P1 B1 P1 C1 P1 D1 Any memory pairs in P1 A2 B2 C2 D2 DIMM slots 2 CPUs amp CPU1 CPU2 4 DIMMs P1 A1 P1 B1 P2 E1 P2 F1 2 CPUs amp CPU1 CPU2 6 DIMMs P1 A1 P1 B1 P1 C1 P1 D1 P2 E1 P2 F1 2 CPUs amp CPU1 CPU2 8 DIMMs P1 A1 P1 B1
51. hange any of these text messages Settings printed in Bold are the default values A b gt indicates a submenu Highlighting such an item and pressing the lt Enter gt key will open the list of settings within that submenu The BIOS setup utility uses a key based navigation system called hot keys Most of these hot keys lt F1 gt lt F10 gt lt Enter gt lt ESC gt lt Arrow gt keys etc can be used at any time during the setup navigation process 7 2 Main Menu When you first enter AMI BIOS Setup Utility you will see the Main Menu screen You can always return to the Main Menu by selecting the Main tab on the top of the screen with the arrow keys The Main Menu screen provides you with a system overview which includes the version built date and ID of the AMIBIOS the type speed and number of the processors in the system and the amount of memory installed in the system 7 1 SUPERSERVER 6027R TRF USER S MANUAL System Time System Date You can edit this field to change the system time and date Highlight System Time or System Date using the Arrow keys Enter new values through the keyboard Press the Tab key or the Arrow keys to move between fields The date must be entered in DAY MM DD YY Y Y format The time is entered in HH MM SS format Please note that time is in a 24 hour format For example 5 30 A M appears as 05 30 00 and 5 30 P M as 17 30 00 7 8 Advanced Settings Menu Use the arrow keys to
52. hen working around the backplane Do not touch the back plane with any metal objects and make sure no ribbon cables touch the backplane or obstruct the holes which aid in proper airflow A N Important Regardless of how many hard drives are installed all drive carriers must remain in the drive bays to maintain proper airflow 6 5 SUPERSERVER 6027R TRF USER S MANUAL Figure 6 4 Removing a SAS SATA Drive Carrier Release Button Important All of the drive carriers must remain in the drive bays to maintain proper cooling airflow Hard Drive Backplane The hard drives plug into a backplane that provides power drive ID and bus termination A RAID controller can be used with the backplane to provide data security The operating system you use must have RAID support to enable the hot swap capability of the hard drives The backplane is already preconfigured so no jumper or switch configurations are required 6 6 Chapter 6 Advanced Chassis Setup DVD ROM Installation The top cover of the chassis must be opened to gain full access to the DVD ROM drive bay The 2022G URF accomodates only slim type DVD ROM drives Side mounting brackets are typically needed to mount a slim DVD ROM drive in the server Accessing the Inside of the Chassis 1 Grasp the two handles on either side and pull the unit straight out until it locks you will hear a click 2 Next depress the two buttons on the top of the chassis to release th
53. iate radio frequency energy and if not installed and used in accordance with the manufacturer s instruction manual may cause harmful interference with radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case you will be required to correct the interference at your own expense California Best Management Practices Regulations for Perchlorate Materials This Perchlorate warning applies only to products containing CR Manganese Dioxide Lithium coin cells Perchlorate Material special handling may apply See www dtsc ca gov hazardouswaste perchlorate WARNING Handling of lead solder materials used in this product may expose you to lead a chemical known to the State of California to cause birth defects and other reproductive harm Manual Revision 1 0a Release Date February 21 2012 Unless you request and receive written permission from Super Micro Computer Inc you may not copy any part of this document Information in this document is subject to change without notice Other products and companies referred to herein are trademarks or registered trademarks of their respective companies or mark holders Copyright 2012 by Super Micro Computer Inc All rights reserved Printed in the United States of America Preface Preface About This Manual This manual is written for professional system integrators and PC technicians It provides information for the in
54. iguration Power Button Function If this feature is set to Instant Off the system will power off immediately as soon as the user presses the power button Select 4 Second Override for the system to power off when the user presses the power button for 4 seconds or longer The options are Instant Off and 4 Seconds Override Restore on AC Power Loss Use this feature to set the power state after a power outage Select Power Off for the system power to remain off after a power loss Select Power On for the system power to be turned on after a power loss Select Last State to allow the system to resume its last state before a power loss The options are Power On Stay Off and Last State CPU Configuration This submenu displays the information of the CPU as detected by the BIOS It also allows the user to configure CPU settings Socket 0 CPU Information This submenu displays the following information regarding the CPU installed in Socket 0 Type of CPU CPU Signature Microcode Patch CPU Stepping Maximum CPU Speed Minimum CPU Speed Processor Cores Intel HT Hyper Threading Technology Intel VT x Virtualization Technology Intel SMX Trusted Execution Technology 7 3 SUPERSERVER 6027R TRF USER S MANUAL 1 Data Cache 1 Code Cache L2 Cache 3 Cache gt Socket 1 CPU Information This item displays if a CPU is installed in Socket 1 CPU Speed This item displays the speed of the CP
55. integrity See the table on the right for jumper settings Chapter 5 Advanced Serverboard Setup Watch Dog Enable Disable Jumper Settings JWD Jumper Setting Definition Pins 1 2 Reset Pins 2 3 NMI Open Disabled VGA Enable Disable Jumper Settings JPG1 Jumper Setting Definition Pins 1 2 Enabled Pins 2 3 Disabled BMC Enable Disable Jumper Settings JPB1 Jumper Setting Definition Pins 1 2 BMC Enable Default Pins 2 3 Disabled ME Mode Select Jumper Settings JPME1 Jumper Setting Definition Pins 1 2 Normal Default Pins 2 3 Manufacture Mode Write_Protect Enable Disable Jumper Settings JWP1 Jumper Setting Definition Pins 1 2 Normal Default Pins 2 3 Write_Protect Enabled 5 25 5 10 Onboard Indicators LAN1 2 LEDs There are two GLAN ports on the motherboard Each Gigabit Ethernet LAN port has two LEDs The Yellow LED on the right indicates connection and activity The Link LED on the left side may be green amber or off to indicate the speed of the connection See the tables at right for more information IPMI Dedicated LAN LEDs In addition to LAN 1 LAN 2 an IPMI Dedicated LAN is also located on the I O Backplane of the motherboard The amber LED on the right indicates connection and activity while the green LED on the left indicates the speed of the connection See the tabl
56. ions are Enabled and Disabled Serial Port Mode This feature allows the user to set the serial port mode for Console Redirection The options are SOL and COM Device Settings This feature indicates whether or not a reset is required for a serial port specified Change Settings This option specifies the base I O port address and the Interrupt Request address of Serial Port 1 and Serial Port 2 The options for Serial Port 1 and Port 2 are Auto lO 3F8h IRQ 4 IO 3F8h IRQ 3 4 5 6 7 9 10 11 12 IO 2F8h IRQ 3 4 5 6 7 9 10 11 12 IO 3E8h IRQ 3 4 5 6 7 9 10 11 12 IO 2bE8h IRQ 3 4 5 6 7 9 10 11 12 gt Serial Port Console Redirection These submenus allow the user to configure the following Console Redirection settings for a COM Port 0 or COM Port 1 as specified by the user COM 0 COM 1 Console Redirection Select Enabled to use a COM Port selected by the user for Console Redirection The options are Enabled and Disabled The default setting for COMO is Disabled and for COM1 is Enabled 7 17 SUPERSERVER 6027R TRF USER S MANUAL gt Console Redirection Settings This feature allows the user to specify how the host computer will exchange data with the client computer which is the remote computer used by the user Terminal Type This feature allows the user to select the target terminal emulation type for Console Redirection Selet VT100 to use the ASCII character set Select VT100
57. lizers should be attached to the rack In multiple rack installations the racks should be coupled together Always make sure the rack is stable before extending a component from the rack You should extend only one component at a time extending two or more si multaneously may cause the rack to become unstable Server Precautions Review the electrical and general safety precautions in Chapter 4 Determine the placement of each component in the rack before you install the rails e Install the heaviest server components on the bottom of the rack first and then work up Use a regulating uninterruptible power supply UPS to protect the server from power surges voltage spikes and to keep your system operating in case of a power failure Allow any hot plug drives and power supply modules to cool before touching them Always keep the rack s front door and all panels and components on the servers closed when not servicing to maintain proper cooling 2 2 Chapter 2 Server Installation Rack Mounting Considerations Ambient Operating Temperature If installed in a closed or multi unit rack assembly the ambient operating temperature of the rack environment may be greater than the ambient temperature of the room Therefore consideration should be given to installing the equipment in an environment compatible with the manufacturer s maximum rated ambient temperature Tmra Reduced Airflow Equipment shoul
58. llows the user to set the flow control for Console Redirection to prevent data loss caused by buffer overflow Send a Stop signal to stop sending data when the receiving buffer is full Send a Start signal to start sending data when the receiving buffer is empty The options are None and Hardware RTS CTS 7 18 Chapter 7 BIOS VT UTF8 Combo Key Support Select Enabled to enable VT UTF8 Combination Key support for ANSI VT100 terminals The options are Enabled and Disabled Recorder Mode Select Enabled to capture the data displayed on a terminal and send it as text messages to a remote server The options are Disabled and Enabled Resolution 100x31 Select Enabled for extended terminal resolution support The options are Disabled and Enabled Legacy OS Redirection Use this feature to select the number of rows and columns used in Console Redirection for legacy OS support The options are 80x24 and 80x25 Putty Keypad Use this feature to select function key and keypad setting on Putty The options are VT100 LINUX XTERMR6 SCO ESCN and VT400 Out of Band Mgmt Port Use this feature to select the port for out of band management The options are COMO and COM1 Serial Port for Out of Band Management Windows Emergency Management Services EMS This item allows the user to configure Console Redirection settings to support Out of Band Serial Port management ACPI Settings Use this feature to configure Advanced Configuratio
59. n and Power Interface ACPI power management settings for your system ACPI Sleep State Use this feature to select the ACPI State when the system is in sleep mode Select S1 CPU Stop Clock to erase all CPU caches and stop executing instructions Power to the CPU s and RAM is maintained but RAM is refreshed Select Suspend to use power reduced mode Power will only be supplied to limited components such as RAMs to maintain the most critical functions of the system The options are S1 CPU Stop Clock and Suspend Disabled 7 19 SUPERSERVER 6027R TRF USER S MANUAL Numa This feature enables the Non Uniform Memory Access ACPI support The options are Enabled and Disabled High Precision Timer Select Enabled to activate the High Precision Event Timer HPET that produces periodic interrupts at a much higher frequency than a Real time Clock RTC does in synchronizing multimedia streams providing smooth playback reducing the de pendency on other timestamp calculation devices such as an x86 RDTSC Instruc tion embedded in the CPU The High Performance Event Timer is used to replace the 8254 Programmable Interval Timer The options are Enabled and Disabled gt Trusted Computing Available if a TPM device is installed Configuration TPM Support Select Enabled on this item and enable the TPM jumper on the motherboard to allow TPM support to improve data integrity and network security The options are Enabled and Disabled C
60. n each system reboot Select No to keep all system event logs after each system reboot The options are No Yes On next reset and Yes On every reset 7 22 Chapter 7 BIOS When SEL is Full This feature allows the user to decide what the BIOS should do when the system event log is full Select Erase Immediately to erase all events in the log when the system event log is full The options are Do Nothing and Erase Immediately Cstom EFI Logging Options Log EFI Status Codes Select Enabled to log EFI Extensible Firmware Interface Status Codes Error Codes or Progress Codes The options are Disabled and Enabled Note After making changes on a setting be sure to reboot the system for the changes to take effect gt BMC Network Configuration LAN Channel 1 This feature allows the user to configure the settings for LAN Channel 1 Update IPMI LAN Configuration This feature allows the user to decide if the BIOS should configure the IPMI setting at next system boot The options are No and Yes If the option is set to Yes the user is allowed to configure the IPMI settings at next system boot Configuration Address Source This feature allows the user to select the source of the IP address for this computer If Static is selected you will need to know the IP address of this computer and enter it to the system manually in the field If Unspecified is selected the BIOS will search the next available IP address for this computer wi
61. nP Configuration This submenu allows the user to configure the following PCle PCI PnP settings PCI ROM Priority Use this feature to select the Option ROM to boot up the system when there are multiple Option Roms available in the system The options are Legacy ROM and EFI Compatible ROM PCI Latency Timer Use this feature to set the latency timer of each PCI device installed on a PCI bus Select 64 to set the PCI latency to 64 PCI clock cycles The options are 32 64 96 128 160 192 224 and 248 Above 4G Decoding Available if the system supports 64 bit PCI decoding Select Enabled to decode a PCI device that supports 64 bit in the space above 4G Address The options are Enabled and Disabled PERR Generation Select Enabled to allow a PCI device to generate a PERR number for a PCI Bus Signal Error Event The options are Enabled and Disabled 7 15 SUPERSERVER 6027R TRF USER S MANUAL SERR Generation Select Enabled to allow a PCI device to generate a SERR number for a PCI Bus Signal Error Event The options are Enabled and Disabled Maximum Payload This feature selects the setting for the PCIE maximum payload size The options are Auto 128 Bytes 256 Bytes 512 Bytes 1024 Bytes 2048 Bytes and 4096 Bytes Maximum Read Request This feature selects the setting for the PCIE maximum Read Request size The options are Auto 128 Bytes 256 Bytes 512 Bytes 1024 Bytes 2048 Bytes and 4096 Bytes ASPM Support This feat
62. ns are 0 1 8 and 16 7 10 Chapter 7 BIOS Perfmon and DFX Devices A PerfMon device monitors the activities of a remote system such as disk usage memory consumption and CPU load which will allow an IT administrator to maximize the performance of each computer within the network A DFX device usually in the form of a USB adaptor can be used to enhance audio performance Select Unhide to display the Perfmon and DXF devices installed in the system The options are HIDE and UNHIDE DRAM RAPL Mode RAPL which stands for Running Average Power Limit is a feature that provides mechanisms to enforce power consumption limits on supported processors The options are DRAM RAPL MODEO DRAM RAPL MODE 1 and Disabled MPST Support Select Enabled to enable the Message Processing Subscriber Terminal which is used to process short messages The options are Disabled and Enabled DDR Speed Use this feature to force a DDR3 memory module to run at a frequency other than what the system is specified in the specification The options are Auto Force DDR3 800 Force DDR3 1066 Force DDR3 1333 Force DOR3 1600 and Force SPD Channel Interleaving This feature selects from the different channel interleaving methods The options are Auto 1 Way 2 Way 3 Way and 4 Way Rank Interleaving This feature allows the user to select a rank memory interleaving method The options are Auto 1 Way 2 Way 4 Way and 8 Way Patrol Scrub Patrol
63. o avoid possible explosion 5 14 Chapter 5 Advanced Serverboard Setup H8DGU F Quick Reference Jumper Description Default Setting JBT1 CMOS Clear See Section 2 7 JPB1 BMC Enabled Pins 1 2 Enabled JPG1 VGA Enabled Pins 1 2 Enabled JPL1 GLAN1 GLAN2 Enable Pins 1 2 Enabled JPME1 Manufacture Mode Pins 1 2 Normal JWD Watch Dog Timer Enable Pins 1 2 Reset JWP1 Write Protect Enable Pins 1 2 Normal LED Description State Status DM1 BMC Heartbeat LED Green BMC Normal LE1 Standby PWR LED Green On SB Power On Connector Description COM1 COM2 Backplane COM Port1 Front Accessible COM2 Header FAN1 6 FAN A FAN B CPU System Fan Headers I SATA 0 1 Intel SB SATA 3 0 Connectors 0 1 Color White I SATA 2 5 Intel SB SATA 2 0 Connectors 2 5 Color Black J22 JPWR3 ATX 24 Pin Power Connector JPWR1 2 12V 8 Pin Power Connectors JD1 Speaker Power LED Indicator JF1 Front Panel Control Header JIPMB1 4 pin External BMC I C Header for an IPMI Card JL1 Chassis Intrusion JOH1 Overheat LED Indicator JP3 BIOS Recovery JPFC1 Power Supply SMBbus C Header JSTBY1 Standby Header JTPM1 TPM Trusted Platform Module Port 80 JWF1 SATA DOM Disk on Module Power Connector Keyboard Mouse PS2 Keyboard Mouse optional LAN1 LAN2 1G LAN Ethernet Ports 1 2 IPMI LAN IPMI Dedicated LAN T SGPIO 1 2 Serial Link General Purpose I O Headers BP USB 0 1 2 3 USB 4 5 USB 6 USB 8 9 USB 10 11 VGA Back Panel USB 0 1 2 8
64. on in the processor via automatic voltage control during processor idle states The options are Disabled and CLTT Closed Loop Thermal Throttling OLTT Peak BW Use this feature to set a percentage of the peak bandwidth allowed for OLTT Enter a number between 25 to 100 The default setting is 50 gt South Bridge This feature allows the user to configure the settings for the Intel PCH chip PCH Information This feature displays the following PCH information Name This item displays the name of the PCH chip Stepping This item displays the status of the PCH stepping 7 12 Chapter 7 BIOS All USB Devices Select Enabled to enable all onboard USB devices The options are Enabled and Disabled EHCI Controller 1 EHCI Controller 2 Select Enabled to enable Enhanced Host Interface EHCI Controller 1 or Controller 2 to improve overall platform performance The options are Enabled and Disabled Legacy USB Support Available when USB Functions is not Disabled Select Enabled to support legacy USB debvices Select Auto to disable legacy support if USB devices are not present Select Disable to have USB devices available for EFI Extensive Firmware Interface applicatioins only The settings are Enabled Disabled and Auto Port 60 64 Emulation Select Enabled to enable I O port 60h 64h emulation support for the legacy USB keyboard so that it can be fully supported by the operating systems that do not recognize a
65. ontrol Panel Buitons i or rre cte LE Sd ERI RO rii 3 1 3 3 3 4 Chapter 4 System Safety 4 1 Electrical Safety Preca tiors eir ritenere 4 1 4 2 General Safety Precautions eese 4 2 4 3 ESD Precautions e e edet ED e HE aea 4 3 4 4 Operating Precautions sssssseeeeneeneneeeenee nennen 4 4 Chapter 5 Advanced Serverboard Setup 5 1 Handling the Serverboard PRECAUTIONS e Unpacking ees os cee 5 2 Processor and Heatsink Installation Installing a Passive CPU Heatsink Removing the Heatsink cierre re rer aee R FL HERES XR ERI CX HEIL 5 3 Connecting Cables e eet etre tede ees Connecting Data Cables essen Connecting Power Cables rc den TE en eres Connecting the Control Panel rni re epe ns 5 4 JO POS nte eot ene hr de Beer ei p cern E a n Dues 5 5 Jjnstalling MemoTDnyjs seio e cre err ERE e ta CE RERO sig ccnesbasantsaseagnabadsseasenpaloaays Memory S pport Rr DIMM Module Population Configuration z 56 Adding PCI Expansion Cards sisirin eoe eee vii SUPERSERVER 6027R TRF USER S MANUAL 5 7 5 8 5 9 5 10 5 11 5 13 6 1 6 2 6 3 Serverboard Details 2 Fe eire este descended 5 14 H8DGU F Quick Reference iocari an t rct n 5 15 Connector DETINITIONS ec roodo cete eet te AS Mise on ah esu 5 16 Jumper Settings
66. ort for Port 1B The options are GEN1 GEN2 and GENS IOU2 PCle Port This feature allows the user to set the PCI Exp bus speed between IOU2 and PCIe port The options are x4x4x4x4 x4x4x8 x8x4x4 x8x8 and x16 and Auto Port 2A Link Speed Select GEN1 to enable PCI Exp Generation 1 support for Port 2A Select GEN2 to enable PCI Exp Generation 2 support for Port 2A Select GEN3 to enable PCI Exp Generation 3 support for Port 2A The options are GEN1 GEN2 and GENS IOU3 PCle Port This feature allows the user to set the PCI Exp bus speed between IOU3 and PCIe port The options are x4x4x4x4 x4x4x8 x8x4x4 x8x8 and x16 and Auto Port 3A Link Speed Select GEN1 to enable PCI Exp Generation 1 support for Port 3A Select GEN2 to enable PCI Exp Generation 2 support for Port 3A Select GEN3 to enable PCI Exp Generation 3 support for Port 3A The options are GEN1 GEN2 and GENS Port 3C Link Speed Select GEN1 to enable PCI Exp Generation 1 support for Port 3C Select GEN2 to enable PCI Exp Generation 2 support for Port 3C Select GENS to enable PCI Exp Generation 3 support for Port 3C The options are GEN1 GEN2 and GEN3 7 8 Chapter 7 BIOS IOH 1 PCle Port Bifuracation Control This submenu allows the user to configure the following 6 PCle Port Bifurcation Control settings for the IOH 1 PCI Exp port This feature determines how to distribute the available PCI Express lanes to the PCI E Root Ports 10U1 PCle Port This feature
67. ply fan and system temperatures See the table on the right for pin definitions 5 21 Chapter 5 Advanced Serverboard Setup TPM Port 80 Header Pin Definitions JTPM1 Pin Definition Pin Definition 1 LCLK 2 GND 3 LFRAME 4 KEY 5 LRESET 6 5V X 7 LAD 3 8 LAD 2 9 3 3V 10 LADI 11 LADO 12 GND 13 SMB CLK4 14 SMB_DAT4 15 83V DUAL 16 SERIRQ 17 GND 18 CLKRUN X 19 LPCPD 20 LDRQ amp X Overheat LED Pin Definitions JOH1 Pin Definition 1 VDC 2 OH Active OH Fan Fail LED Status State Message Solid Overheat Blinking Fan Fail PWR SMB Pin Definitions JI2C1 Pin Definition Ground PWR Fail SUPERSERVER 6027R TRF USER S MANUAL IPMB IPMB Header Pin Definiti A System Management Bus header for UIPMBI IPMI 2 0 is located at JIPMB1 Connect Pin amp Definition the appropriate cable here to use the EE A IPMB I C connection on your system 2 reum 3 Clock 4 No Connection T SGPIO 1 2 Headers SGPIO Header Pin Definitions Two SGPIO Serial Link General FSGPIOTTSGPIO2 Purpose Input Output headers are Pin Definition Pin Definition located on the motherboard These i ne e Gem headers support Serial Link interface 3 Ground 4 DataOut for onboard SATA connections See 5 Load 6 Ground the table on the right for pin definitions 7
68. r if neces sary Use only one hand when working with powered on electrical equipment This is to avoid making a complete circuit which will cause electrical shock Use extreme caution when using metal tools which can easily damage any electrical components or circuit boards they come into contact with Do not use mats designed to decrease static electrical discharge as protection from electrical shock Instead use rubber mats that have been specifically designed as electrical insulators The power supply power cords must include a grounding plug and must be l in roun lectrical l 4 1 SUPERSERVER 6027R TRF USER S MANUAL This product may be connected to an IT power system In all cases make sure that the unit is also reliably connected to Earth ground Serverboard Battery CAUTION There is a danger of explosion if the onboard battery is installed upside down which will reverse its polarites see Figure 4 1 This battery must be replaced only with the same or an equivalent type recommended by the manufacturer Dispose of used batteries according to the manufacturer s instructions DVD ROM Laser CAUTION this server may have come equipped with a DVD ROM drive To prevent direct exposure to the laser beam and hazardous radiation exposure do not open the enclosure or use the unit in any uncon ventional way Mainboard replaceable soldered in fuses Self resetting PTC Positive Tempera ture Coefficient fuses on the
69. ring boot The options are Enabled and Disabled Erasing Settings Erase Event Log This option erases all logged events The options are No Yes Next reset and Yes Every reset When Log is Full This option automatically clears the Event Log memory of all messages when it is full The options are Do Nothing and Erase Immediately 7 21 SUPERSERVER 6027R TRF USER S MANUAL Smbios Event Log Standard Settings Log System Boot Event This option toggles the System Boot Event logging to enabled or disabled The options are Disabled and Enabled MECI The Multiple Event Count Increment MECI counter counts the number of occurences a duplicate event must happen before the MECI counter is incremented This is a numeric value ranging from 1 to 255 METW The Multiple Event Time Window METW defines number of minutes must pass between duplicate log events before MECI is incremented This is in minutes from 0 to 99 View Smbios Event Log This feature displays the contents of the SmBIOS Event Log View System Event Log This feature displays the contents of the System Event Log 7 5 IPMI gt System Event Log Enabling Disabling Options SEL Components Select Enabled for all system event logging at bootup The options are Enabled and Disabled Erasing Settings Erase SEL Select Yes On next reset to erase all system event logs upon next system reboot Select Yes On every reset to erase all system event logs upo
70. rmware Hub flash memory System BIOS 1 MB 3 99 GB Local APIC 4KB 3 99 GB Area Reserved for the chipset 2MB 3 99 GB I O APIC 4 Kbytes 4KB 3 99 GB PCI Enumeration Area 1 256 MB 3 76 GB PCI Express 256 MB 256 MB 3 51 GB PCI Enumeration Area 2 if needed Aligned on 256 M 512 MB 3 01 GB boundary VGA Memory 16 MB 2 85 GB TSEG 1 MB 2 84 GB Memory available for the OS amp other applications 2 84 GB 5 12 Chapter 5 Advanced Serverboard Setup 5 6 Adding PCI Expansion Cards PCI Expansion Slots One riser card is used to support PCI expansion cards in the system The RSC R2UU UA3E8 riser card can support one UIO card and three full height full length PCI Express x8 expansion cards Installing a PCI Add on Card 1 Remove the chassis cover 2 Release the locking tab that corresponds to the PCI slot shield for the slot you wish to populate 3 Insert the expansion card into the riser card pushing down with your thumbs evenly on both sides of the card 4 Slide the add on card into the riser card and attach the add on card bracket in place of the PCI slot shield 5 Secure the add on card by closing the PCI slot shield lever 6 Connect cables to the add on card as necessary Note If the left side riser is with 2 or more x8 PCI E slots make sure an installed card on the left side riser is detected If it is not then go to the system s BIOS Setup and in Advanced PCI PnP Configuration
71. run with a failed fan Remove the top chassis cover while the system is still running to determine which of the fans has failed SUPERSERVER 6027R TRF USER S MANUAL Replacing System Fans Removing a Fan 1 Remove the chassis cover 2 Press the tabs on the sides of the fan to unlock and remove the fan and its housing The fan s power connections will automatically detach 3 System power does not need to be shut down since the fans are hot pluggable Installing a New Fan 1 Replace the failed fan with an identical 8 cm 12 volt fan available from Supermicro p n FAN 0126L4 2 Position the new fan into the space vacated by the failed fan previously removed A click can be heard when the fan is fully installed in place and the power connections are made 3 If the system power is on the hot plug feature will cause the fan to start immediately upon being connected to its header on the serverboard 6 4 Drive Bay Installation Removal Accessing the Drive Bays SATA Drives You do not need to access the inside of the chassis or remove power to replace or swap SATA drives Proceed to the next step for instructions You must use standard 1 high SATA drives in the system DVD ROM For installing removing the DVD ROM drive you will need to gain access to the inside of the server by removing the top cover of the chassis Proceed to the DVD ROM Installation section later in this chapter for instructions Note Refer to
72. s the user to configure the following security settings for the system Administrator Password Use this feature to set the Administrator Password which is required to enter the BIOS setup utility The length of the password should be from 3 characters to 8 characters long User Password Use this feature to set a User Password which is required to log into the system and to enter the BIOS setup utility The length of the password should be from 3 characters to 8 characters long 7 24 Chapter 7 BIOS 7 8 Save amp Exit This menu allows the user to configure the Save and Exit settings for the system Discard Changes and Exit Select this option to quit the BIOS Setup without making any permanent changes to the system configuration and reboot the computer Select Discard Changes and Exit and press lt Enter gt When the dialog box appears asking you if you want to exit the BIOS setup without saving click Yes to quit BIOS without saving the changes or click No to quit the BIOS and save changes Save Changes and Reset When you have completed the system configuration changes select this option to save the changes and reboot the computer so that the new system configuration parameters can take effect Select Save Changes and Exit and press Enters When the dialog box appears asking you if you want to exit the BIOS setup without saving click Yes to quit BIOS without saving the changes or click No to quit the BIOS and save
73. s where heat electrical noise and electromagnetic fields are generated You will also need it placed near a grounded power outlet Read the Rack and Server Precautions in the next section 2 3 Preparing for Setup The box the SUPERSERVER 6027R TRF was shipped in should include two sets of rail assemblies two rail mounting brackets and the mounting screws you will need to install the system into the rack Follow the steps in the order given to complete the installation process in a minimum amount of time Please read this section in its entirety before you begin the installation procedure outlined in the sections that follow Choosing a Setup Location Leave enough clearance in front of the rack to enable you to open the front door completely 25 inches and approximately 30 inches of clearance in the back of the rack to allow for sufficient airflow and ease in servicing 2 1 SUPERSERVER 6027R TRF USER S MANUAL This product is for installation only in a Restricted Access Location dedicated equipment rooms service closets and the like This product is not suitable for use with visual display work place devices acccording to 2 of the the German Ordinance for Work with Visual Display Units AN Warnings and Precautions A N Rack Precautions Ensure that the leveling jacks on the bottom of the rack are fully extended to the floor with the full weight of the rack resting on them In single rack installation stabi
74. s with different electrical charges coming into contact with each other An electrical discharge is created to neutralize this difference which can damage electronic components and printed circuit boards The following measures are generally sufficient to neutralize this difference before contact is made to protect your equipment from ESD Use a grounded wrist strap designed to prevent static discharge Keep all components and printed circuit boards PCBs in their antistatic bags until ready for use Touch a grounded metal object before removing the board from the antistatic bag Do not let components or PCBs come into contact with your clothing which may retain a charge even if you are wearing a wrist strap Handle a board by its edges only do not touch its components peripheral chips memory modules or contacts When handling chips or modules avoid touching their pins Put the serverboard and peripherals back into their antistatic bags when not in use For grounding purposes make sure your computer chassis provides excellent conductivity between the power supply the case the mounting fasteners and the serverboard 4 3 SUPERSERVER 6027R TRF USER S MANUAL 4 4 Operating Precautions A Care must be taken to assure that the chassis cover is in place when the 6027R TRF is operating to assure proper cooling Out of warranty damage to the system can occur if this practice is not strictly followed Figure 4 1 In
75. sabled and Enabled Package C State Limit If set to Auto the AMI BIOS will automatically set the limit on the C State package register The options are CO C2 C6 C7 and No Limit Energy Performance The options are Performance Balanced Performance Balanced Energy and Energy Efficient Factory Long Duration Power Limit This item displays the power limit set by the manufacturer during which long duration power is maintained Long Duration Power Limit This item displays the power limit set by the manufacturer during which long duration power is maintained 7 6 Chapter 7 BIOS Factory Long Duration Maintained This item displays the period of time set by the manufacturer during which long duration power is maintained Long Duration Maintained This item displays the period of time during which long duration power is maintained Recommended Short Duration Power This item displays the short duration power settings recommended by the manufacturer Short Duration Power Limit This item displays the period of time during which short duration power is maintained gt Chipset Configuration gt North Bridge This feature allows the user to configure the settings for the Intel North Bridge IOH IO Hub Configuration Intel VT d Select Enabled to enable Intel Virtualization Technology support for Direct I O VT d by reporting the I O device assignments to the VMM Virtual Working Memory through the DMAR ACPI Tables This fea
76. select Advanced and press Enter to access the following submenu items Boot Feature Quiet Boot Set this value to allow the bootup screen options to be modified between POST messages or the OEM logo Select Disabled to allow the computer system to display the POST messages Select Enabled to allow the computer system to display the OEM logo The default setting is Enabled AddOn ROM Display Mode This sets the display mode for the Option ROM Select Keep Current to use the current AddOn ROM Display setting Select Force BIOS to use the Option ROM display mode set by the system BIOS The options are Force BIOS and Keep Current Bootup Num Lock Use this feature to set the Power on state for the Numlock key The options are Off and On Wait For F1 If Error Select Enabled force the system to wait until the F1 key is pressed when an error occurs The options are Disabled and Enabled Interrupt 19 Capture Interrupt 19 is the software interrupt that handles the boot disk function When this item is set to Enabled the ROM BIOS of the host adaptors will capture Interrupt 19 at boot and allow the drives that are attached to these host adaptors to function as bootable disks If this item is set to Disabled the ROM BIOS of the host adaptors will not capture Interrupt 19 and the drives attached to these adaptors will not function as bootable devices The options are Enabled and Disabled 7 2 Chapter 7 BIOS Power Conf
77. set the BIOS temperature threshold settings again you would first need to uninstall SuperDoctor Figure 5 8 Supero Doctor Ill Interface Display Screen Health Information SuperDoctor III Remote Management 5 29 SUPERSERVER 6027R TRF USER S MANUAL Figure 5 9 Supero Doctor Ill Interface Display Screen Remote Control SuperDoctor III Remote Management ifo Healt Remote Control Graceful power control cancelable Supero Doctor III allows a user to inform the OS to reboot or shut down the system within 30 seconds On the system console a pop up window will appear with a message telling the local user to save his working files Before the system reboots or shuts down it s allowed to cancel the action either locally or remotely Power control noncancelable Supero Doctor III allows a user to inform the OS to reboot or shut down the system right away The system will reboot or shut down without any warning messages It s not allowed to cancel the action il Note The SuperDoctor III program and User s Manual can be downloaded from the Supermicro web site at http www supermicro com products accessories software SuperDoctorlll cfm For Linux we recommend that you use the SuperoDoctor II application instead 5 30 Chapter 6 Advanced Chassis Setup Chapter 6 Advanced Chassis Setup This chapter covers the steps required to install components and perform maintenance on the SC825TS R
78. ssembly consists of two sections an inner fixed chassis rail that secures directly to the server chassis and an outer fixed rack rail that secures directly to the rack itself Installing the Inner Rail Extension The SC825 chassis includes a set of inner rails in two sections inner rails and inner rail extensions The inner rails are pre attached to the chassis and do not interfere with normal use of the chassis if you decide not to use a server rack The inner rail extension is attached to the inner rail to mount the chassis in the rack Installing the Inner Rails 1 Place the inner rail extensions on the side of the chassis aligning the hooks of the chassis with the rail extension holes Make sure the extension faces outward just like the pre attached inner rail 2 Slide the extension toward the front of the chassis 3 Secure the chassis with 2 screws as illustrated Repeat steps for the other inner rail extension 2 4 Chapter 2 Server Installation Figure 2 1 Separating the Rack Rails Separating the Inner and Outer Rails 1 Rail Assembly 1 Locate the rail assembly in the chassis packaging 2 Extend the rail assembly by pulling it outward 3 Press the quick release tab Separate the inner rail extension from the outer rail assembly N Quick Release Tab Separating O the Inner Rail Seen 2 5 SUPERSERVER 6027R TRF USER S MANUAL Figure 2 2 Assembling the Outer Rails Outer R
79. ssis cover The hard drives can be installed and removed from the front of the chassis without removing the top chassis cover A slim DVD ROM may be preinstalled in your server Refer to Chapter 6 if you need to install a DVD ROM drive to the system Depending upon your system s configuration your system may have one or more drives already installed If you need to install hard drives please refer to Chapter 6 Checking the Airflow 1 Airflow is provided by three hot swappable 8 cm chassis cooling fans The System component layout was carefully designed to direct sufficient cooling airflow to the components that generate the most heat Note that all power and data cables have been routed in such a way that they do not block the airflow generated by the fans Providing Power 1 Plug the power cord s from the power supply unit s into a high quality power strip that offers protection from electrical noise and power surges It is recommended that you use an uninterruptible power supply UPS Depress the power on button on the front of the chassis 2 10 Chapter 3 System Interface Chapter 3 System Interface 3 1 Overview There are several LEDs on the control panel of the 6027R TRF server as well as others on the drive carriers to keep you constantly informed of the overall status of the system as well as the activity and health of specific components There are also two buttons on the chassis control panel 3 2
80. sssseeeeeeenenen nennen 7 2 Advanced Settings Men ntt eve rni e e d dug 7 2 Event EOgS cotaioieo n esiti creo Reit uen ces detades EIU EEEE e RRE 7 21 jx A 7 22 BO0l coe tenente tue conven ri osha Fev nui enaends Po HEC RE RP cea DO 7 24 SECUN mem 7 24 SriuEdliee C H 7 25 7 8 Appendix A BIOS Error Beep Codes Appendix B System Specifications viii Chapter 1 Introduction 1 1 Chapter 1 Introduction Overview The SUPERSERVER 6027R TRF is a high end server comprised of two main subsystems the SC825TS R740LPBP 2U server chassis and the X9DRi F dual processor serverboard Please refer to our web site for information on operating Systems that have been certified for use with the system www supermicro com In addition to the serverboard and chassis various hardware components have been included with the 6027R TRF as listed below Two 2 2U Passive CPU Heatsinks SNK PO048PS One 1 Air shroud MCP 310 29001 0N Two 2 2U passive CPU heat sinks SNK P0048PS Three 3 80x80x38 mm Chassis Middle Fans FAN 0126L4 One 1 76 cm round 16 to 16 pin Ribbon FP Cable CBL 0017L SAS SATA Accessories One 1 SAS SATA backplane BPN SAS 825TQ Two 2 40 cm 8 to 8 pin ribbon cable w tube for SGPIO CBL 157L Six 6 61 cm flat SATA cables CBL 0044L Eight 8 hot swap 3 5 hard disk drive tra
81. stallation and use of the SUPERSERVER 6027R TRF Installation and maintainance should be performed by experienced technicians only The SUPERSERVER 6027R TRF is a high end server based on the SC825TS R740LPBP 2U rackmount chassis and the X9DRi F dual processor serverboard Manual Organization Chapter 1 Introduction The first chapter provides a checklist of the main components included with the server system and describes the main features of the X9DRi F serverboard and the SC825TS R740LPBP chassis Chapter 2 Server Installation This chapter describes the steps necessary to install the SuperServer 6027R TRF into a rack and check out the server configuration prior to powering up the system If your server was ordered without processor and memory components this chapter will refer you to the appropriate sections of the manual for their installation Chapter 3 System Interface Refer here for details on the system interface which includes the functions and information provided by the control panel on the chassis as well as other LEDs located throughout the system Chapter 4 System Safety You should thoroughly familiarize yourself with this chapter for a general overview of safety precautions that should be followed when installing and servicing the SuperServer 6027R TRF Chapter 5 Advanced Serverboard Setup Chapter 5 provides detailed information on the X9DRi F serverboard including the locations and functions of connections
82. stalling the Onboard Battery LITHIUM BATTERY BATTERY HOLDER way a damaged battery may release hazardous materials into the envi ronment Do not discard a used battery in the garbage or a public landfill Please comply with the regulations set up by your local hazardous waste management agency to dispose of your used battery properly Please handle used batteries carefully Do not damage the battery in any 4 4 Chapter 5 Advanced Serverboard Setup Chapter 5 Advanced Serverboard Setup This chapter covers the steps required to install processors and heatsinks to the X9DRi F serverboard connect the data and power cables and install add on cards All serverboard jumpers and connections are described and a layout and quick reference chart are included in this chapter Remember to close the chassis completely when you have finished working on the serverboard to protect and cool the system sufficiently 5 1 Handling the Serverboard Static electrical discharge can damage electronic components To prevent damage to printed circuit boards it is important to handle them very carefully see Chapter 4 Also note that the size and weight of the serverboard can cause it to bend if handled improperly which may result in damage To prevent the serverboard from bending keep one hand under the center of the board to support it when handling The following measures are generally sufficient to protect your equipment from static
83. t straight out until it locks you will hear a click Next depress the two buttons on the top of the chassis to release the top cover You can then lift the top cover from the chassis to gain full access to the inside of the server Checking the Components and Setup 1 You may have one or two processors already installed into the serverboard Each processor needs its own heat sink See Chapter 5 for instructions on processor and heat sink installation Your 6027R TRF server system may have come with system memory already installed Make sure all DIMMs are fully seated in their slots For details on adding system memory refer to Chapter 5 If desired you can install add on cards to the system See Chapter 5 for details on installing PCI add on cards Make sure all power and data cables are properly connected and not blocking the chassis airflow Also make sure that no cables are positioned in front of the fans See Chapter 5 for details on cable connections 2 8 Chapter 2 Server Installation Figure 2 3 Accessing the Inside of the System 2 9 SUPERSERVER 6027R TRF USER S MANUAL 2 6 Checking the Drive Bay Setup Next you should check to make sure the peripheral drives and the SAS SATA drives have been properly installed and all connections have been made Checking the Drives ils All drives are accessable from the front of the server For servicing the DVD ROM you will need to remove the top cha
84. tel Intelligent Power Node Manager NM 1 4 Manageability Engine MB 2 trie rrr pe EP erret ire tege 1 4 Contacting SUpettfilCro cot reiecit cin ed ee eva Per n rt e t e s 1 6 Chapter 2 Server Installation 2 1 2 2 2 3 Warnings and Precautions 2 4 OVeIVIGW inis cence acct sec ICM IM MR IM dM LEE ME 2 1 Unpackirig the System iit aire Ee cerent vt reti ni iere ERES 2 1 Preparing Tor Setups eed et tt na Casa techn dde ue gated 2 1 Choosing a Setup LOCatior uu ioter ped eere nis 2 1 Rack Precautioris irre Era icr ni ap amio eei e ene d Server Precautions uic niit ere ne ERE SEXE Y EFE No ERE ento o sae ad Rack Mounting Considerations aeneae eoe edes Ambient Operating Temperature Reduced Airflow C SEERE Mechanical Loading casei rette e D rare ero tees EAER Circ it Overloadirig o i orici n er n itt dns Reliable Ground eio odore Een ne hiat ext mnes etie nes Aa EE SERE EREEREER Installing the System into Rack eere Separating the Sections of the Rack Rails seeees 2 4 vi Table of Contents Installing the Inner Rail Extension ssseeseeeeen 2 4 Outer Rack Rails 5 eene idee tn n n da en 2 6 2 5 Checking the Serverboard Setup sace eet eines 2 8 2 6 Checking the Drive Bay Setup Chapter 3 System Interface 3 1 OVEINVICW cn anter rra ED E EO REOR ree Rardin 3 1 3 2 C
85. the airflow in mind when routing the cables The following data cables with their connector locations noted should be connected See the serverboard layout diagram in this chapter for connector locations e SGPIO cables T SGPIO 1 2 SATA cables i SATA 0 5 Control Panel cable JF1 see next page Connecting Power Cables The X9DRi F has a 24 pin primary power supply connector designated JPWR3 for connection to the ATX power supply Connect the appropriate connector from the power supply to JPWR3 to supply power to the serverboard See the Connector Definitions section in this chapter for power connector pin definitions In addition your power supply must be connected to the two 8 pin Processor Power connectors at JPWR1 and JPWR2 Connecting the Control Panel JF1 contains header pins for various front control panel connectors See Figure 5 1 for the pin locations of the various front control panel buttons and LED indicators Even and odd numbered pins are on opposite sides of each header All JF1 wires have been bundled into single keyed ribbon cable to simplify their connection The red wire in the ribbon cable plugs into pin 1 of JF1 Connect the other end of the cable to the Control Panel printed circuit board located just behind the system status LEDs in the chassis See the Connector Definitions section in this chapter for details and pin descriptions of JF1 5 8 Chapter 5 Advanced Serverboard Setup Fi
86. the following ftp site for setup guidelines lt ftp ftp supermicro com driver SAS LSI LSI SAS EmbMRAID SWUG pdf and Supermicro s web site for additional inmformation lt http www supermicro com support manuals gt Warning Enterprise level hard disk drives are recommended for use AN in Supermicro chassis and servers For information on recommended HDDs visit the Supermicro Web site at http www supermicro com products nfo files storage SAS CompList pdf 6 4 Chapter 6 Advanced Chassis Setup SATA Drive Installation These drives are mounted in carriers to simplify their installation and removal from the chassis The carriers also help promote proper airflow for the drives For this reason even empty carriers without hard drives installed must remain in the chassis Mounting a SATA Drive in a Drive Carrier 1 To add a new SATA drive install the drive into the carrier with the printed circuit board side facing down so that the mounting holes align with those in the carrier 2 Secure the drive to the carrier with four screws as shown in Figure 6 3 Installing Removing Hot swap SATA Drives 1 Push the release button located beside the drive s LEDs 2 Swing the handle fully out and use it to pull the drive carrier straight out see Figure 6 4 Note Your operating system must have RAID support to enable the hot plug capability of the drives Figure 6 3 Mounting a SAS SATA Drive in a Carrier Use caution w
87. thout modifying BMC network parameters The options are Static and DHCP Station IP Address This item displays the Station IP address for this computer This should be in decimal and in dotted quad form i e 192 168 10 253 Subnet Mask This item displays the sub network that this computer belongs to The value of each three digit number separated by dots should not exceed 255 Station MAC Address This item displays the Station Mac address for this computer Mac addresses are 6 two digit hexadecimal numbers 7 23 SUPERSERVER 6027R TRF USER S MANUAL Router IP Address This item displays the Router IP address for this computer This should be in decimal and in dotted quad form i e 192 168 10 253 Router MAC Address This item displays the Router Mac address for this computer Mac addresses are 6 two digit hexadecimal numbers 7 6 Boot Boot Option Priorities Boot Option 1 Boot Option 2 Boot Option 3 Use this feature to specify the sequence of boot device priority Network Device BBS Priorities Hard Drive BBS Priorities This option sets the order of the legacy network devices and Hard Disks detected by the motherboard gt Delete Boot Option This feature allows the user to delete a previously defined boot device from which the system boots during startup Boot Option 1 Boot option 2 Boot Option 3 The settings are Built in EFI Shell and any pre defined boot device 7 7 Security This menu allow
88. to Chapter 6 for instructions on replacing failed drives Red When this LED flashes it indicates the drive is rebuilding When solid on it indicates a SAS drive failure If a drive fails you should be notified by your system management software Please refer to Chapter 6 for instructions on replacing failed drives 3 3 SUPERSERVER 6027R TRF USER S MANUAL Notes Chapter 4 System Safety 4 1 Chapter 4 System Safety Electrical Safety Precautions A Basic electrical safety precautions should be followed to protect yourself from harm and the SUPERSERVER 6027R TRF from damage Be aware of the locations of the power on off switch on the chassis as well as the room s emergency power off switch disconnection switch or electrical outlet If an electrical accident occurs you can then quickly remove power from the system Do not work alone when working with high voltage components Power should always be disconnected from the system when removing or in stalling main system components such as the serverboard memory modules and floppy drive When disconnecting power you should first power down the operating system first and then unplug the power cords The unit has more than one power supply cord Disconnect two power supply cords before servicing to avoid electrical shock When working around exposed electrical circuits another person who is familiar with the power off controls should be nearby to switch off the powe
89. ture offers fully protected I O resource sharing across Intel platforms providing greater reliability security and availability in networking and data sharing The options are Enabled and Disabled Intel I OAT The Intel I OAT I O Acceleration Technolgy significantly reduces CPU overhead by leveraging CPU architectural improvements freeing the system resource for other tasks The options are Disabled and Enabled DCA Support Select Enabled to use Intel s DCA Direct Cache Access Technolgy to improve data transfer efficiency The options are Enabled and Disabled 7 7 SUPERSERVER 6027R TRF USER S MANUAL IOH 0 PCle Port Bifurcation Control This submenu allows the user to configure the following 8 PCle Port Bifurcation Control settings for the IOH 0 PCI Exp port This feature determines how to distribute the available PCI Express lanes to the PCI E Root Ports 10U1 PCle Port This feature allows the user to set the PCI Exp bus speed between IOU1 and PCl e port The options are x4x4 and x8 Port 1A Link Speed Select GEN1 to enable PCI Exp Generation 1 support for Port 1A Select GEN2 to enable PCI Exp Generation 2 support for Port 1A Select GEN3 to enable PCI Exp Generation 3 support for Port 1A The options are GEN1 GEN2 and GENS Port 1B Link Speed Select GEN1 to enable PCI Exp Generation 1 support for Port 1B Select GEN2 to enable PCI Exp Generation 2 support for Port 1B Select GEN3 to enable PCI Exp Generation 3 supp
90. ure allows the user to set the Active State Power Management ASPM level for a PCI E device Select Force LO to force all PCI E links to operate at LO state Select Auto to allow the system BIOS to automatically set the ASPM level for the system Select Disabled to disable ASPM support The options are Disabled Auto and Force LOs Onboard LAN Option ROM Select This feature selects whether to load the iSCSI or PXE onboard LAN option ROM The options are iSCSI and PXE Load Onboard LAN1 Option ROM Load Onboard LAN2 Option ROM Select Enabled to enable the onboard LAN1 Option ROM LAN4 Option ROM This is to boot the computer using a network device The default setting for LAN1 Option ROM is Enabled the default setting for LAN2 Option ROM is Disabled VGA Priority Use this feature to specify which graphics controller to be used as the primary boot device The options are Onboard and Offboard VGA Network Stack Select Enabled to enabel PXE Preboot Execution Environment or UEFI Unified Extensible Firmware Interface for network stack support The options are Enabled and Disabled 7 16 Chapter 7 BIOS gt Super IO Configuration WPCM450 Super IO Chip Displays the Super IO chip type gt Serial Port 0 Configuration Serial Port 1 Configuration The submenus allow the user to configure the following settings for Serial Port 0 or Serial Port 1 Serial Port Select Enabled to enable a serial port specified by the user The opt
91. urrent Status Information This item displays the information regarding the current TPM status TPM Enable Status This item displays the status of TPM Support to indicate if TPM is currently enabled or disabled TPM Active Status This item displays the status of TPM Support to indicate if TPM is currently active or deactivated TPM Owner Status This item displays the status of TPM Ownership Intel TXT LT SX Configuration Intel TXT Trusted Execution Technology helps protect against software based attacks and ensures protection confidentiality and integrity of data stored or created on the system 7 20 Chapter 7 BIOS ME Management Engine Subsystem Intel ME Subsystem Configuration This feature displays the following ME Subsystem Configuration settings ME Subsystem Select Enabled to support Intel Management Engine ME Subsystem a small power computer subsystem that performs various tasks in the background The options are Enabled and Disabled When ME Subsystem is enabled the following items will display ME BIOS Interface ME Version To set this feature select Load Fail Safe Defaults from the Exit menu and press Enter The Fail Safe settings are designed for maximum system stability but not maximum performance 7 4 Event Logs Change SmBIOS Event Log Settings Enabling Disabling Options Smbios Event Log Change this item to enable or disable all features of the Smbios Event Logging du
92. vers amp Tools WinXP X Intel Chipset INF files SUPERMIC Re Matrox G200e Graphics Driver Svara m Drivers amp Tools Microsoft Net Framework Optional Intel C602 C606 Chipset X9DR3 i F LSI MegaRAID Storage Manager Intel Rapid Storage Technology Enterprise Intel PRO Network Connections Drivers Trusted Platform Module Driver Optional SUPERMICRO SuperDoctor Ill SUPERMICRO Computer Inc Build driver diskettes and manuals Browse CD T Auto Start Up Next Time f For more information please visit SUPERMICRO s web site 5 28 Chapter 5 Advanced Serverboard Setup Supero Doctor Ill The SuperDoctor III program is a Web base management tool that supports remote management capability It includes Remote and Local Management tools The local management is called SD III Client The SuperDoctor IIl program included on the CD ROM that came with your motherboard allows you to monitor the environment and operations of your system SuperDoctor III displays crucial system information such as CPU temperature system voltages and fan status See the Figure below for a display of the SuperDoctor III interface Note The default User Name and Password for SuperDoctor III is ADMIN ADMIN Note When SuperDoctor is first installed it adopts the temperature threshold settings that have been set in BIOS Any subsequent changes to these thresholds must be made within SuperDoctor as the SuperDoctor settings override the BIOS settings To
93. w P DBOOBGBOgquooog Sac D Fe D LUBSUUD D cs J 9 tj L J a eee eile esr a C ieee HZOSS et acl 4 COO C EUH eo 7 me orts COM1 Port Ethernet Ports 6 2 Control Panel The control panel located on the front of the chassis must be connected to the JF1 connector on the serverboard to provide you with system status indications A ribbon cable has bundled these wires together to simplify the connection Connect the cable from JF1 on the serverboard to the Control Panel PCB printed circuit board Make sure the red wire plugs into pin 1 on both connectors Pull all excess cabling out of the airflow path The LEDs inform you of system status See Chapter 3 for details on the LEDs and the control panel buttons Details on JF1 can be found in Chapter 5 6 2 Chapter 6 Advanced Chassis Setup 6 3 System Fans Three 8 cm hot swap fans provide the cooling for the system It is very important that the chassis top cover is properly installed and making a good seal in order for the cooling air to circulate properly through the chassis and cool the components See Figure 6 2 Figure 6 2 Removing System Cooling Fans System Fan Failure Fan speed is controlled by system temperature via a BIOS setting If a fan fails the remaining fans will ramp up to full speed and the overheat fan fail LED on the control panel will turn on Replace any failed fan at your earliest convenience with the same type and model the system can continue to
94. ys MCP 220 00075 0B One 1 Rackmount kit MCP 290 00053 0N One CD containing drivers and utilities 1 1 SUPERSERVER 6027R TRF USER S MANUAL 1 2 Serverboard Features At the heart of the SUPERSERVER 6027R TRF lies the X9DRi F a dual processor serverboard based on the Intel PCH C602 C606 chipset Below are the main features of the X9DRi F See Figure 1 1 for a block diagram of the chipset Processors The X9DRi F supports single or dual E5 2600 Series processors in Socket R LGA2011 type sockets Please refer to our web site for a complete listing of supported processors www supermicro com Memory The X9DRi F has sixteen 16 single dual tri quad channel 240 pin DIMM sockets that can support up to 512 GB of DDR3 1600 1333 1066 800 MHz speed registered ECC SDRAM in two channel memory bus Memory sizes of 1GB 2GB 4GB 8GB 16GB and 32GB 9 1 35V 1 5V voltages are supported Please refer to Chapter 5 for installing memory Serial ATA An on chip PCH C606 SATA controller is integrated into theX9DRi F to provide a six port 3 Gb sec SATA subsystem which is RAID 0 1 5 and 10 supported The SATA drives are hot swappable units Note You must have RAID set up to enable the hot swap capability of the SATA drives Documentation on RAID setup guidelines can be found on our web site Onboard Controllers Ports The color coded I O ports on the X9DRi F include two COM ports one header and one port a VGA monitor port