1. AUTION This device to be used in conjunction with other diagnostic proce dures and not relied on exclusively CAUTION Do not autoclave the unit CAUTION This device has been tested and found to comply with EMC limits for the Medical Device Directive 93 42 EEC as last amended by 2007 47 EC EN 60601 1 2 These limits are designed to provide reasonable protection against harmful interference in a typical medical installation However there is not guarantee that interference will occur in a particular installation The device generates radio frequency and if not installed and used in accordance with these instructions may cause harmful interference to other devices in the vicinity If this device does cause harmful interference with other devices which can be determined by turning the device off and on the user is encouraged to try to cor rect the interference by one or more of the following measures e Reorient or relocate the receiving device e Increase the separation between devices e Consult the manufacturer for help CAUTION To reduce the risk of electrical shock do not remove cover Refer servicing to qualified service personnel CAUTION U S Federal Law restricts this device to sale by or on the order of a healthcare professional CAUTION contains parts and assemblies susceptible to damage by Electro Static Discharge ESD Symbols Corresponds to MDD 93 42 EEC as last amended by 2007 47 EC Attention Consult manual b
2. Accessories Not included e Long Sensor Probe DE002 1 10 e Extension Cables DE002 1 7 Classification e Type BF applied part e EC 601 1 Compliant Medical Equipment e Internally powered equipment e Continuous operation e Device is not supplied in a sterile state e Ordinary protection against ingress of water is required Technical Specifications e Power Supply Single AA battery e Power input 1 0 1 5 V Maximum current SOMA Operating temperature 10 C 40 C Humidity 10 90 without condensation Transport Storage 15 C 50 C 13 14 Cautions and Warnings DANGER Not for use in the presence of a flammable anesthetic mixture with air or with oxygen or nitrous oxide Non AP and non APG equipment WARNING The Apex Locator should NOT be used on a patient with a pace maker WARNING Do not plug any connectors or pins on the file clip or probes into any external power source as it may cause a severe safety hazard to the patient WARNING Only use the specified battery WARNING Use of other accessories which are not authorized for use in con nection with this device may cause malfunction and compromise patient safety CAUTION This device has been investigated with regard to safety from electri cal shock and fire hazard as well as electromagnetic compatibility EMC The device has not been investigated for other physiological effects CAUTION For use by qualified and trained personnel only C
3. Digital Apex Locator Models ApexDAL DAL 001 ApexNRG Blue BI 001 OPERATING MANUAL MEDICI ey Precise Endo Technolog DI DAWN Main lead wires Mini file holder Lip hook Apron clasp On Button Flashing LEDs The Digital Apex Locator is designed to meet international safety and performance standards Personnel operating the instrument must have a thorough understanding of the proper operation of the instrument These instructions have been prepared to aid medical and technical personnel to understand and operate the instrument Do not operate the instrument before reading this manual and gaining a clear understanding of the operation of the instrument If any part of this manual is not clear please contact your representative for clarification The Digital Apex Locator calculates the distance from the tip of your endodontic file to the Major Apical Foramen by using multi frequency currents The Digital Apex Locator measures the response of the root canal between two electrodes depending on the frequency The first electrode is the lip hook 3 Pic A The second is the mini file holder 2 which makes contact with a file that has bee inserted into the root canal The Digital Apex Locator monitors the changes in the canal s response as the file probe approaches the apex Technologically Advanced e There are 8 LEDs to mark the advancement of the file for precise working length measurement e The use of D
4. SP allows a much higher level of accuracy and control of the process with measurement results accurate to 0 1 mm in apical region and a display resolution of 0 25 mm in the critical measurement range e The Digital Apex Locator provides precise measurements of the canal under all conditions including wet dry and bleeding canals You can immediately measure another canal without any special preparation e Calibration is automatic No manual calibration is required Initial Setup Insert the two main lead wires into the outlets on the right side of the Digital Apex Locator Pic B Insert the mini file holder and lip hook into the sockets located at the end of each lead wire either left or right pic C and Pic D Attach the apron clasp to the lead wires by inserting them into the two wire holders on the clasp handles Pic E Insert the Digital Apex Locator into a disposable sleeve Pic F Place the Digital Apex Locator near the mouth of the patient and attach the clasp to the apron Pic G Place the lip hook located at the end of the cable on the lower lip preferably on the opposite side of the tooth being treated Pic G 7 Connect the file to the mini file holder pic H then place the file at the en trance to the canal pic Now you are ready to begin treatment Pic l Pic J Directions For Use NOTE Digital Apex Locator should be used only as an adjunct to normal endodontic procedu
5. arning to replace battery as soon as possible As a warning of this every other LED will flash several times before going off Replace battery The x ray is a two dimensional image which cannot accurately find the biologi cal apex Therefore the result of the apex locator should be relied upon for deter mining the correct working length In addition bone or periodontal ligament loss indicated by a radiolucency on the film can cause inaccurate readings Battery is low Replace battery The battery has been inserted incorrectly The sign should be facing the spring The correct battery insertion position is etched on the device See battery replacement instructions for more information Included in box Digital Apex Locator 1 unit Lead Wires 4 units autoclavable File Clip Cable 1 unit autoclavable Lip Hook 2 units autoclavable Apron Clasp 2 units autoclavable Mini File Holder 3 units autoclavable Mini Sensor Probe 1 unit autoclavable Disposable Sleeves Packet 20 sleeves Battery type AA ApexNRG Blue additional parts e Rechargeable battery type AA 2 units e Battery Charger e Bluetooth Dongle e USB Extension Cable e Software Installation CD Part numbers for re order e Lead Wires DEQOS 1 1 e File Clip Cable DEOO3 1 2 e Lip Hook DE002 1 3 e Apron Clasp XFR 001 3 e Mini File Holder XFR 001 4 e Mini Sensor Probe DE002 1 9 e Disposable Sleeves Packet DE002 1 4
6. e the battery when storing for an extended period of time Dispose of depleted battery in accordance to local regulations Pica Sterilization Warning Do not place the Digital Apex Locator Blue into the Autoclave Do not submerge the device or allow liquid to enter the unit enclosure The main lead wires mini file holder lip hook file clip cable mini sensor probe and apron clasp can be sterilized in the autoclave according to the autoclave manufacturer s instructions usually at 121 C for 20 minutes or at 134 C for 5 minutes Attention The Digital Apex Locator is not supplied in a sterile state All surfaces of the device and its accessories should be disinfected when the unit is initially received and thereafter between procedures to prevent cross infection Thoroughly wipe all surfaces of the unit with a clean cloth moistened in 70 ethyl alcohol solution or any medical device disinfectants Recommendations for a successful treatment Prior to measuring root canal length with your Digital Apex Locator e Make sure that the pulp chamber 1 is dry before inserting the measuring file It is recommended to dry the pulp chamber with a cotton pellet or by a slight aspiration of the moisture with an aspiration syringe Also ensure that all canals are isolated from each other Excessive fluids in the pulp chamber or canals may form a conductive bridge between canals or with a metallic restoration or crown Drying the canal
7. eaches the apical constriction the Apex green LED will light and the alarm sound changes to a faster pitch 7 Mark the depth of the canal with the file rubber stop Measure the length of the file and prepare the rest of the files for the treatment according to this length If you pass the apical constriction the mm orange LED will begin to flash and the alarm will sound fastest pitch At this stage gently rotate the file back out of the canal until the Apex mm green LED lights and the alarm sound slows its pitch Please refer to our preparatory recommendations and FAQ sections for more information For your convenience After the length of the canal has been defined and marked on all of the files the compact and convenient Sensor Probe can be used to confirm the depth of the entering file during the procedure The result of the momentary f contact with the file will be shown on your i apex locator immediately Please note Contact should be made increasingly often when approach ing the apical constriction in order to prevent perforation The location of the file will be shown on the apex locator only during direct contact with the sensor Device Power Off As an energy conservation feature the Digital Apex Locator will turn off after ap proximately 3 minutes of non use Battery Power When the Digital Apex Locator recognizes low battery power upon turning on the unit every other LED will light simultane
8. efore use Type BF Patient Applied Part b BI gt Em Caution contains parts and assemblies susceptible to damage by ElectroStatic Discharge ESD Packaging Handling Symbols Fragile handle with care Temperature limits for storage and transportation Keep dry Disposal in municipal waste may be restricted by state or local ordinance Dispose of in accordance with state and local regulations or contact manufacturer for guidance x Bi lei Fa Compliance with specification Test Standard Class Severity level Test result Radiated emission lause 36 201 1 amp Frequency range 30 1000 MHz CISPR 11 Immunity Group 1 Class B Complies DI clause 36 202 2 amp 6 KV contact discharge Complies discharge ESD IEC 61000 4 2 8kV air discharge Immunity 3 0 V m from radiated Eo wri 80 MHz 2 5 GHz Complies electromagnetic fields li 80 AM 1 kHz Immunity from power frequency magnetic field 15 clause 36 202 8 amp IEC 61000 4 8 3 A m 50Hz 60Hz Complies MADE IN ISRAEL Manufacturer MedicNRG Ltd Kibbutz Afikim 15148 ISRAEL Fax 972 4 675 4278 Email info medicnrg com Web www medicnrg com Ec REP MedicNRG USA Toll Free 1 888 429 0240 Email infoUSA medicnrg com Web www medicnrg com usa Copyright 2010 by MedicNRG Ltd All rights reserved No part of these instructions may be reproduced or copied in any form by any means graphic electronic or mechanical includ
9. gth A loose file that does not make continuous contact with the canal wall will be unable to perform accurate measurements e Ensure continuous and strong contact between the file and its holder this may be problematic with the thinner files 6 8 10 mm e In excessively desiccated canals moistening is recommended to improve conductivity This can be performed by slight irrigation and or by slight lubri cation of the file e f the canal is too dry introduce NaOCl to the apical third of the canal Exceptions e Inaverywide canal the Digital Apex Locator may be able to read the measurement only at the tip where the canal constricts toward the apical foramen In such cases only a depth of 0 5 mm and apical foramen will be identified Reading may be improved by using a larger file and making definite contact with the canal wall e The apex locator reading may be unstable in the following tooth pathology situations decay caries in the pulp chamber strong bleeding in the canal metallic restoration periapical lesion open apex 4 excessively wide canal e Bone or periodontal ligament loss indicated by a radiolucency on the film can cause Inaccurate readings e A worn out battery will reduce the accuracy of the reading The battery should be replaced as soon as the instrument s warning signal appears as detailed in the user manual Take care to follow the instructions for connecting the cables to the instrument as specified i
10. ing photocopying typing or information retrieval systems without written permission of MedicNRG Ltd CE FDA510 k cleared 0344 This device complies with the requirements of the MDD 93 42 EEC as last amended by 2007 47 EC APRE Caution US Federal Law restricts the sale of medical devices to health care professionals MK 2UDBT14 B
11. ion e A preliminary extirpation is recommended before beginning measurement Residual tissue may result in a premature and erroneous reading 10 e When using a rubber dam make sure that it is properly sealed around the in sertion area Any aperture between the rubber dam and tooth can be sealed with a temporary restoration Leading endodontists recommend the use of rubber dams during every root canal treatment e Ensurethe lip hook fully contacts the patient s moist mucosa The lip hook should not make contact with any adjacent teeth which may have metal fill Ings e Check all connections e While some of the accessories are autoclavable if any accessory seems damaged after a number of autoclave cycles please replace with a new part Particularly check the lead wire cables see the section on sterilization for a full list of the autoclavable items Recommendations for the measurement process Prepare a wide canal orificium and prepare the first 2 3 in a tapered way to pre vent contact with premature constrictions in the canal e The file should be inserted into the canal in a filing motion clockwise and counter clockwise Rotation of the file in one direction may cause the file to break inside the canal The file should be moved in filing motions e ake care to ensure continuous contact between the file and the root canal wall It is recommended to use the largest possible file that will reach the estimated working len
12. n the user manual In all instances of erroneous readings as described above only a premature reading situation is possible due to ostensible recognition of the apex However the Digital Apex Locator will not show a delayed reading that may endanger the periapical tissues The Digital Apex Locator is a digital electronic device and as such requires a minimum residual battery voltage to drive the circuitry It therefore requires replacement when this point has been reached even thought there may be suf ficient power left for the LEDs to turn on 11 he Troubleshooting Question Unit shows that the file is at the apex when instrument has only just been introduced to the canal Reading on unit is not steady No lights show Several LEDs illuminate simultaneously The reading on the device does not coincide with the result of the X ray The unit will not switch off Unit does not work when battery has been replaced Sol uti on see user manual for fuller explanations Either pulp chamber floor is not complete ly dry or the file has contacted a metallic restoration In either case the inaccurate readings are due to shorting the circuit Dry the pulp chamber if it is wet File is in intermittent contact with the canal walls Either place a curve at the tip of the file or try a larger size file so the tip touches the wall near the apex Battery is flat or has not been replaced correctly see below W
13. ously with beeping sounds This is a warning to change the battery soon still functional If after an additional period of time the operator has not changed the battery the unit will turn off automatically upon being turned on and will not allow the operator to use the unit Replace the battery immediately There are no other user serviceable items within the unit If there are any functional problems with the unit please contact your local MedicNRG representative for further guidance Warning Low battery power affects accuracy NOTE The Digital Apex Locator with Bluetooth is supplied with AA rechargeable batteries and a charger However also regular AA batteries may be used with the device Bluetooth Wireless Transmission consumes additional battery power therefore we recommend that one battery is kept charged at all times in order to allow quick replacement in the event of low battery power Warning Charge only rechargeable batteries Battery Replacement e Removethe battery by sliding out the battery cover on the back of the ApexDAL Pic K e Removethe battery from the device Pic L and replace with a fresh battery type AA e Be sure to insert the battery with the sign toward the spring e Slide the battery cover back into the device until you feel a click Pic M Please note Do not store the device for long periods of time with the battery inside The battery may leak after a long period of disuse Please remov
14. res While the unit can reduce the number of radiographs necessary an initial radiograph must be taken to estimate working length Clinical judgment including knowledge of root canal anatomy is paramount when interpreting results 1 Activate the Digital Apex Locator by pressing the ON button on the face of the unit or by making contact between the lip hook and the mini file holder Pic J Once activated the LEDs will flash in sequence as a self check 2 Following this check the green Power LED will blink indicating the Digital Apex Locator is in stand by mode WMAP IENRG BLUETOOTH DIGITAL APEX LOCATOR 3 When the file reaches the 2 0 mm point the blue LED will light and stay lit 4 Work the file in a clockwise and counter clockwise filing motion towards the apex and back until the 0 5 mm point blue LED turns on and the alarm sounds slow pitch NOTE In order to gain the maximum advantage of this advanced DSP tech nology the file must be manipulated in slow movements towards the apical constriction 0 0 in clockwise and counterclockwise motions This is due to the extremely high accuracy and rapidity of measurement of each minute movement of the file This is especially important in the critical area between 0 5 to the apical constriction 0 0 Swift movement of the file may cause an unsteady LED display 5 Before reaching the apical constriction the 0 25 mm blue LED will light 6 When the file r
15. with a paper point may help increase accuracy e When the walls of the pulp chamber are damaged 2 or there are damaged fillings 3 Saliva leakage can occur from the oral cavity which will prevent drying of the chamber A moist chamber may cause the immediate formation of a closed electrical circuit i e a short circuit In this event the apex locator will issue a warning flashing red LED and audible alarm as if it reached the apex false positive reading In such cases the missing chamber wall should be temporarily restored but only with nonconductive materials such as Composite IRM GI glass iononer etc After restoration a dry chamber can be achieved and accurate measurement can be reached e Check that any damaged fillings 3 have been removed in order to prevent marginal leakage Such leakage will result in a moist working area and may interfere with the Digital Apex Locator s reading The red light will flash indicating that it has identified the apex when in fact the file is only at the canal entrance area e Continuous contact with metal or amalgam fillings will ground the device so take special care to prevent contact between the file and any existing metal based restoration of the tooth by amalgam filing or metal crown In such instances an adequate Isolation of the file from the metallic environment can be achieved by fitting 2 3 rubber stoppers onto the part of the file that may contact the metal of the restorat