Kisae America Car Batteries User Manual

image

Contents

1. e Avoid moisture Never expose unit to water e Unit provides 120Vac from inverter or by pass utility power treat the output socket the same as regular wall AC sockets at home WARNING Explosion hazard e DO NOT use the KISAE Home Solar Kit in the vicinity of flammable fumes or gases such as propane tanks or large engines e AVOID covering the ventilation openings e Always operate unit in an open area e Prolonged contact to high heat or freezing temperatures will decrease the working life of the unit Unit exposure to these elements may lead to cracking and decreased capacity of the internal battery FCC INFORMATION This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generate uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving ant
2. together for 5 secs to enter feature select mode m0 int ma Press Select for 1 sec to change setting Press Power amp Select together for 5 secs to set to select setting and exit feature select mode Press Power for 1 sec to set to select setting and Lenter next setting Press Power amp Select Press Select together for 5 secs to for 1 sec set to select setting and to change setting exit feature select mode CHO CH1 Press Power for 1 sec to set to select setting and Lenter next setting ee Led Press Power amp Select ALO Press Select ALI together for 5 secs to for 1 neo set to select setting and to change setting exit feature select mode Press Power for 1 sec to set to select setting and Lenter next setting Factory Default Press Power for 1 sec to enter next setting and factory default is not set Press Power amp Select together for 5 secs to factory default and exit feature select mode 5 OPERATION WARNING RISK OF EQUIPMENT DAMAGE e Do not plug surge protected power bars into the unit s 120 VAC outlets e Do not connect an AC power source to the 120 VAC outlets e Do not connect the unit s AC power input cord to its 120 VAC outlets Operating the main unit Mode Status Display Condition LED Full Solid Ful AC output is supplied by utility AC power Automa
3. toggle between the three settings e Once the desired setting is selected press and hold Power button for 1 second to set the desired setting and carry on with setting the other feature e Display will show current charger setting as ChO or Ch1 e Press and hold Select button for 1 second to toggle between the two settings e Once the desired setting is selected press and hold Power button for 1 second to set the desired setting and carry on with setting the other features e Display will show current alarm setting as ALO or AL 1 e Press and hold Select button for 1 second to toggle between the two settings e Once the desired setting is selected press and hold Power button for 1 second to set the desired setting and carry with setting the other features e Display will show Fd factory default setting If you desire to use the factory setting press and hold Power and Select button together for 5 seconds to exit the setting mode If you wish to keep all the previous settings on inverter charger and alarm just press Power button for 1 seconds and press and hold Power and select button together for about 5 seconds to exit the feature setting mode Note Press and hold Power and Select button together for 5 seconds at any time to exit the feature setting mode See feature setting chart below Unit in normal operation Press Power amp Select
4. 0W solar panel If a non Home Solar Kit 80W solar panel is use be sure the solar panel is design for a 12V battery system and with maximum open circuit voltage less than 25 VDC Please refer to the specifications label on the solar panel before connecting Do not connect with PV source capable of delivering more than 8 amps Connect solar panel with higher voltage or current rating will permanently damage the unit and may cause fire and energy hazard CAUTION Reverse polarity Improper connections reversing the wire connection on the solar panel connection box will cause the unit to malfunction and may permanently damage the unit Damage caused by a reverse polarity connection is not covered by your warranty e Plug in the solar panel cord plug to the solar input port located at the back of the KISAE Home Solar Kit battery box Please noted the polarity of the connector e Remove the opaque sheet or flip the solar panel with solar cell surface facing upwards Adjust the mounting fringe of the solar panel to have the solar cell surface facing directly to the sunlight to achieve the maximum power When sunlight is available the solar charge indicator should automatically turn on and the Solar Charge Indicator should either flash or solid depending on the battery status NOTE It is recommended to always charge the internal battery to a 100 state of charge as shown by a steady green on Solar charger indicator Disconnect Solar Panel fr
5. attery draw unit in standby DC Input Voltage operating range Internal AC Charger Specification Output Current Output Voltage Absorption Float Recharge Voltage Efficiency Charger type Solar Panel Charger Specification Output Current Output Voltage Recharge Voltage Input DC Voltage Efficiency Charger Type Battery Specification Battery Capacity Battery Type Regulatory Approval ETL certify KISAE BATTERY 12A 1440W continuous 15A 1800W maximum 2880W peak 120 VAC 60 Hz Modified Sinewave 90 lt 3W 10 5 15 5 Vdc 5 ADC 14 8 13 5 VDC 12 6 VDC 80 3 stages bulk absorption float 8A maximum 14 8 13 5 VDC 12 6 VDC 9 26 VDC maximum gt 95 PWM control 12V 60Ah Sealed Lead Acid Deep cycle Conforms to UL 1778 Certified to CSA C22 2 no 107 1 CAR BATTERIES
6. enna e Increase the separation between the equipment and the receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio TV technician for help LIMITATIONS ON USE Do not use in connection with life support systems or other medical equipment or devices BATTERY RECYCLING The unit is designed to provide years of service However the internal battery is not designed to be user replaceable E the internal battery installed inside the battery box contains lead which can be hazardous if exposed to the environment the battery box should be recycled or safely disposed of at your local recycling depot Do not dispose of the battery box with common household waste Please ask your local authorities about recycling services that are available in your area PRODUCT DESCRIPTION The KISAE Home Solar Kit package includes the items list below e Home Solar Kit base unit P N HS 1800 60 e 80W Folding Solar Panel P N HS SP80 12 e Owner s manual P N HS MU1800 INSTALLATION Solar Panel Owner s n manual Start Fo k DULUTH pere WARNING FAILURE TO FOLLOW THESE INSTRUCTIONS CAN DAMAGE THE UNIT Before beginning your KISAE Home Solar Kit Installation please consider the following e The KISAE Home Solar Kit base unit should be used or stored in an indoor area away from direct sun
7. g the KISAE Home Solar Kit READ ALL instructions and cautionary markings on or provided with the inverter charger the batteries and all appropriate sections of this guide The KISAE Home Solar Kit contains no user serviceable parts See Warranty section for how to handle product issues FIRE AND OR CHEMICAL BURN HAZARD e Do not cover or obstruct any air vent openings and or install in a zero clearance compartment e Do not use the KISAE Home Solar Kit if the unit is visibly leaking some type of liquid It is possible that the internal battery has been damaged and battery acid may have spilled FAILURE TO FOLLOW THESE INSTRUCTIONS CAN RESULT IN DEATH OR SERIOUS INJURY e When working with electrical equipment or lead acid batteries have someone nearby in case of an emergency e Wear eye protection and gloves e Avoid touching your eyes while using this unit e Keep fresh water and soap on hand in the event battery acid comes in contact with eyes If this occurs cleanse right away with soap and water for a minimum of 15 minutes and seek medical attention e Batteries produce explosive gases DO NOT smoke or have an open spark or fire near the system e Keep unit away from moist or damp areas e Avoid dropping any metal tool or object on the battery Doing so could create a spark or short circuit which goes through the battery or another electrical tool that may create an explosion WARNING Shock Hazard Keep away from children
8. ility AC power si green Chg amp XX Charging of internal battery by 5A charger battery is in progress capacity in Backup Same as Backup disable mode but with audio alarm disabled The unit disable fault protection features remain active and will shut down without audio with alarm warning when fault occurs disable In0 Ch1 AIO Backup Solid Ful AC output is supplied by utility AC power and green and battery is full charge charger Green XxX in AC output is supplied by utility AC power disable and display shows battery capacity In0 ChO Al Oor AI1 Operating the PV Solar Input The battery box is comes with a solar input port and a DC to DC controller that provides an alternative method to charge the internal battery A solar charge indicator located at the back of the battery box to indicate the charging status of the internal battery The DC to DC controller is a fully automatic self sustaining device that will initiate the charge cycle when solar power is available Please note that the DC to DC controller is designed to be used with the provided KISAE 80W solar panel Connected to other solar panel may damage the unit or over charge the battery If insufficient charge capacity is not available from the solar source it is recommended to use the internal 5A charger to complete the battery charging process through the utility Understanding the Error Codes Error Condition Corrective Act
9. ion Code E01 Inverter has sensed input under Recharge battery immediately and voltage and has shutdown restart unit E02 Inverter has sensed input over voltage and has shutdown Check battery voltage or if any external charger is connected to the battery box E03 Inverter output has sensed Check load connected to the output overload or short circuit and was Reduce load and restart the unit shutdown E04 Inverter has sensed internal Turn unit off and wait for 15 minutes shutdown temperature was high and has before restarting Check if any object has blocked the air flow of the unit E05 Inverter has sensed low voltage input and warning occurs Recharge battery as unit will shut down shortly E06 Inverter has sensed output load is Check load connected to the output high and overload shutdown is Reduce load near E07 Inverter has sensed internal Reduce load and check if any temperature is high and is close to thermal shutdown limit ventilation of the unit is blocked E08 09 Not used E10 Battery reaches high voltage Check battery voltage or if any external charger is connected to the battery box E11 Transfer relay has sensed high temperature and shutdown Check load connected to the output Reduce load and check if any ventilation of the unit is blocked E12 Not used Estimate Run time on Load Following run time is an estimate based on using a single batter
10. it do not accept modified sine wave waveform Products are not compatible with the modified sine wave output produced by the KISAE Home Solar Kit See Precaution for using rechargeable application on page XX Insufficient run time Battery is not fully charged Charge battery by leaving the unit plugged to the utility for more than 24 hrs to fully charge the battery or leave the solar panel plugged into the battery box for more than 72 hrs Battery is near the end of it s life Replace battery box Solar Charger indicator is not ON when solar Solar panel cannot supply sufficient power to start the solar charger and Check location and direction of solar panel panel is charge the battery connected Wrong wire connection on Verify solar panel junction box solar panel junction box connection Ground fault is detected Check for any damage on solar on the solar panel and it panel Replace Ground Fault shuts down the solar Detection fuse located at the back of panel DC to DC controller battery box Unit has no Unit is off Turn unit on output Unit has shutdown due to Check utility battery voltage and various potential conditions unit settings See Unit Operation section 7 SPECIFICATIONS Note Specifications are subject to change without notices Inverter Specification Output Current Power Surge Power Output Voltage Output Waveform Peak Efficiency No Load b
11. light heat moisture or conductive contaminants The solar panel of course can be installed outdoors where the best access to sunlight occurs e When placing the unit allow a minimum of three inches of space around the unit for optimal ventilation When placing the unit allow a minimum of three inches of space around the unit for optimal ventilation e Charge battery immediately upon purchasing this product e To ensure optimum battery run time and life expectancy leave KISAE Home Solar Kit continuously plugged into utility AC power and or leave solar panel plugged into the unit to charge internal battery Main Unit Installation IMPORTANT The AC plug on the power supply cord is used as the disconnect device The socket outlet shall be installed near the equipment and shall be easily accessible To install the unit plug the AC input power cord directly into a wall outlet and unit is ready to use Note Although the unit is grounded through the ground pin of the AC plug it is highly recommended to ground the battery box through the Grounding Electrode Terminal locates at the back of the battery box Follow instruction below to test the unit e Turn unit on by pressing and holding the Power button for about a second until a beep sound occur The Status light turns on indicating the KISAE Home Solar Kit is ON The unit is functioning in standby mode and is ready to provide backup power AC output is now being provided directly fro
12. m utility power e Ifthe battery capacity is low and needs to be recharged the LED screen on display flashes CHG during the charging process and flashes Ful until battery is fully charged e Unplug the input power cord to simulate power failure The status LED on display will turns amber indicate unit is running in backup power mode AC output is now being provided from battery power e Reconnect the AC power cord into a wall outlet will switch unit back to standby mode and AC output is now being provided directly from utility power again e The unit is successfully installed and functioning properly PV Solar Panel Installation OC Change Range 135 148 Vee Ring Clr pet fort ti Batter di Solar DC Charge inpue 175 Vide nominali 8 Ad Masi Power TOW Macon Earn Type 12V GOK Nan Spilabie Sealed Lead Acid gr SOLAR CHARGE EAN O EAL oa Intertek es GROUND FAULT was Serale 222 Made in China Patent Pending a gt WARNING Shock fire and energy hazards Make sure the solar panel is covered with an opaque sheet or facing the ground before connected or disconnected the cable wire to the solar panel junction box All wiring must be done in accordance with applicable local and national electrical wiring codes Connect Unit to Solar Panel WARNING Shock fire and energy hazards The Solar input port is rated at 17 5V 8A and is designed to be used with the supplied Home Solar Kit 8
13. mg PON KISAE Home Solar Kit 1800 Owner s Manual Model HS 1800 60 INTRODUCTION Thank you for purchasing the KISAE Home Solar Kit With our state of the art easy to use design this product will offer you reliable service for providing a solar powered rechargeable power source for your home cabin or campsite With its highly technical design and comprehensive features the KISAE Home Solar Kit will provide you with a simple yet effective user experience as you learn to generate your own power The KISAE Home Solar Kit can run many AC powered appliances whenever you need power Its battery is expandable for times when you require longer run times and its automatic transfer switch built inside means that you can switch seamlessly from household utility power to the power you generate from the sun This manual will explain how to use this unit safely and effectively Please read and follow these instructions and precautions carefully NOTE Upon purchasing immediately charge unit through utility power for 24 to 48 hours or through the solar panel for more than 72 hrs To guarantee maximum device performance and life span it is recommended to continuously connect the unit to utility power or solar panel to top up the internal battery or else to charge the unit after each use and once every 90 days IMPORTANT SAFETY INFORMATION This section contains important safety information for the KISAE Home Solar Kit Each time before usin
14. mode but with alarm disabled Cho Priority with Audio alarm will not sound when any warning or fault ALO Alarm occurs The unit fault protection features remain active Disable and will shut down without audio warning when fault occurs Ind Backup AC output is provided by AC utility when utility is available Ch1 Disable Internal battery is automatically charged by the 5A AL charger Inverter is disabled and no backup power occurs when AC utility is not available Audio alarm is enabled and will sound when any warning or fault occurs Ind Backup amp Same as Backup disable mode but with alarm disabled Ch1 Alarm Audio alarm will not sound when any warning or fault ALO Disable occurs The unit fault protection features remain active and will shut down without audio warning when fault occurs Ind Backup amp AC output is from utility AC power No AC output when Cho Charger utility AC is not available ALI Disable Ino Backup AC output is from utility AC power No AC output when Cho Charger amp utility AC is not available Alarm ALO Disable Unit Display Label as shown Utility BackUp Fault O To change unit function e To enter the feature setting mode press and hold Power and Select button together for about 5 seconds until a beep is sounded Display will show current inverter setting as InO or In1 or In2 e Press and hold Select button for 1 second to
15. multiple battery boxes CONFIGURATION Please read the following table to fully understand unit settings and desire your own desirable settings Unit default setting is Full Automatic In1 Ch1 Al Understanding of Unit Setting Inverter Setting Ind Inverter is disabled unit will not provide backup function when utility power is not available In1 Inverter is set to standby mode Unit will provide backup function when utility power is not available In2 Inverter is forced to turn on even when AC utility power is available The inverter will only switch back to utility mode when internal battery is getting low With this setting the 5A internal charger is set to Cho by default Charger Setting Cho Internal 5A charger is disabled The charger will not charge the internal battery when utility AC is available Ch1 Internal 5A charger is enabled Charger will automatically charge the internal battery when AC is available Alarm Setting ALO Audio alarm sound is disabled Alarm will not sound when warning and fault occur AL1 Audio alarm sound is enabled Alarm sounds when warning or fault occurs Unit Function Setting Settin Mode of Unit Function g Operation In1 Full AC output is provide by AC utility when utility is available Ch1 Automatic Internal battery is automatically charged by the 5A AL1 Factory charger default AC output will automatically switch to inverter mode power by the i
16. nternal battery when utility is not available Audio alarm is enabled and will sound when any warning or fault occurs In1 Full Same as Full automatic mode but with alarm disabled Chi Automatic Audio alarm will not sound when any warning or fault ALO Silent occurs The unit fault protection features remain active and will shutdown without audio warning when fault occurs Int Auto Same as Full automatic mode but with 5A AC charger Cho Backup disabled AL with AC Battery can only be charged by the solar panel or external Charger charger Disable Only use this mode when there is sufficient solar power or external charger to charge the internal battery Int Auto Same as Auto backup with AC charger disable mode Cho Backup but with alarm disabled ALO with AC Audio alarm will not sound when any warning or fault Charger amp occurs The unit fault protection features remain active Alarm and will shutdown without audio warning when fault Disable occurs In2 Setting is Not available for user setting Chi not ALO OF 1 available In2 Backup Unit will provide output using battery and solar power as Cho Priority higher priority AL AC output will only switch to utility mode when battery is low and available Audio alarm is enabled and will sound when any warning or fault occurs Note Only use this mode when there is sufficient solar power to power up the load In2 Backup Same as Backup priority
17. om Unit e Cover the solar panel with an opaque sheet or flip the solar panel with the solar cell facing a flat ground to minimize the output voltage to zero volts e Verify the Solar charge indicator is off e Disconnect the solar cable connector from the solar input port of the unit Install a Second Battery Box optional Connect the unit with a second battery box P N HSK BX60 will double the unit run time Follow the detail installation guide provide with the second battery box for second battery box installation See also below a brief guideline to access the built in auxiliary DC input port on this main unit and how the secondary battery box is connected e Please be sure the AC power cord is unplugged and the unit is turned off e Remove the top right panel by unscrewing the two screws located on the top right corners of the panel The auxiliary port is located inside the compartment rs e Place the optional battery box P N HSK BX60 on the right hand side of the main unit e Ground the two battery boxes together and to earth ground by using the supplied ground cable through the Grounding Electrode Terminal e Take out the auxiliary DC input port from the main unit and connect it to the second battery box output port e The uniti s now ready to provide power to double the run time Tips The second battery box is design to be stackable Using the above procedure can paral lel
18. r panel or XX battery charger capacity in Flashing Same as Same as above and utility AC power is just amber above detected and AC Output will switch to utility power within a few seconds Solid red E01 E11 Error on unit is detected AC output is disconnected See Trouble Shooting section Auto Same as Auto backup with AC charger disable mode but with audio backup alarm disabled The unit fault protection features remains active and will with shut down without audio warning when fault occurs internal AC charger and alarm disable In1 Cho AIO Raclaun Solid Flash between AC output power is supplied by the inverter priority amber Output Power through internal battery and or solar power In2 Ch0 XXX in kW amp AI1 battery capacity XX in Solid XxX in AC output is supplied by utility AC power green Display shows battery capacity Solid red E01 E11 Error on unit is detected AC output is disconnected See Trouble Shooting section Backup Same as Backup Priority mode but with audio alarm disabled The unit priority fault protection features remain active and will shut down without audio with alanvi warning when fault occurs disable In2 Ch0 Al 0 Backup Solid Ful AC output is supplied by utility AC power disable green Internal battery is fully charged In0 Ch1 Flashing Flash between AC output is supplied by ut
19. tic Ireen Internal battery is fully charged In1 Ch1 Flashing Flash XX AC output is supplied by utility AC power Alt green battery 7 Charging of internal battery by 5A charger capacity in is in progress Solid Flash between AC output power is supplied by the inverter amber Output Power through internal battery and or your KISAE X XX in KW amp solar power or another external solar panel XX battery or external charger capacity in Flashing Same as Same as above and utility AC power is just amber above detected and AC output will switch to utility power within a few seconds Solid red E01 E11 Error on unit is detected AC output is disconnected See Trouble shooting section Same as Full Automatic Mode but with audio alarm disabled The unit Teta fault protection features remain active and will shut down without audio Silent warning when fault occurs In1 Ch1 AIO Auto Solid Ful AC output is supplied by utility AC power backup green Internal battery is fully charged with XX X in AC output is supplied by utility AC power internal Internal battery is not fully charged Display AC show battery capacity charger disable Solid Flash between AC output power is supplied by the inverter Int ChO amber Output Power through internal battery and or KISAE solar Alt X XX in KW amp panel or another external sola
20. y box with 60AH battery on specific load used for testing Actual run time may vary Load Consumption Estimate Run time Cordless Phone 5W 90 hrs Home Alarm System 5W 90 hrs Clock Radio 8W 50 hrs Table Lamp 40W 60W 10 hrs 6 hrs Freezer 8 8 cu ft 80W 4 5 hrs 20 LCD TV 100W 4 0 hrs Refrigerator 18 cu ft 120W 3 5 hrs Sump Pump 1 2 hp 300W 55 min Microwave mid size 1000W 20 min Coffee Maker 1200W 10 min Tips Maximize the usage of your KISAE Home Solar Kit During times of power outage here are some tips to maximize your run times for key back up power applications e Do not leave appliances on when not in use because they will drain the internal battery e For computer use use laptop or desktop computer with LCD monitor instead of desktop computers with CRT monitor e Use small televisions instead of big screen TV s e Use small desk lamps 25 to 40 W instead of high wattage lamps Battery Replacement The battery box contains a 60AH battery Qualified battery electronic technician is required to replaced the battery To replace the battery please contact customer service for details TROUBLESHOOTING To trouble shoot the unit please note the error code display on the main unit and review the Understanding the Error Codes in section 5 Problem Symptom Solution Products connected to unit malfunction or overheat Products connected to un

Download Pdf Manuals

image

Related Search

Related Contents

LG L1942T User's Manual  Slim & Light FLOOR SANITIZER  (仮称)愛西市学校給食センター整備・運営事業 契約書(案)  Installation and Operating Instructions  FICHE PRODUIT ROBOMOW® TUSCANIA® 1500  Druck DPI 740 - GE Measurement & Control  SL1995-4C - McCauley Propeller Systems  EZTrac Manual  Istruzioni per l`uso  RECORD OF ORAL HEARING  