ZB-2550(P)/ZB-2551(P)

image

Contents

1. o oo 18 2 2 PROD OT GINA nee ee rer 20 Operating Mode 1 Transparenf lt lt lt sssssssssa 20 Operating Mode 2 2 Packet ss sssssretsnemsssbiriestersstnsnssenbniesssetoneenses redester 21 Operating Mode 3 Packet Addressable lt lt lt lt lt s2 22 2 3 ZigBee Network GIOUDS nenne 23 ZB 2550 P ZB 2551 P User Manual Ver1 0 March 2009 2 Sis 1 Introduction ZigBee is a specification based on the IEEE 802 15 4 standard for wireless personal area networks WPANs ZigBee operates in the ISM radio bands and its focus is to define a general purpose inexpensive self organizing mesh network that can be used for industrial control embedded sensing medical data collection smoke and intruder warning building automation home automation and domotics etc At present the ICP DAS ZigBee converter ZB 2550 and ZB 2551 supports the RS 232 and RS 485 interfaces The main design goal is limited data communication using wireless transmission so may provide a better solution for environments where wiring is difficult ZB 2550 P ZB 2551 P User Manual Ver1 0 March 2009 3 She 1 1 More Information The ZB 2550 and the ZB 2551 are small sized wireless ZigBee converters based on the IEEE 802 15 4 standard They allow RS 485 RS 232 interfaces to be converted to a ZigBee wireless network Only one ZB 2550 Host is allowed in a ZigBee networ
2. Format 115200 n 8 1 Operating Mode Transparent Default settings for the ZB 2551 are as follows ZB Node ID 0x0020 ZB Pan ID 0xFF00 ZB Chamnel RF Channel 0x00 ZBSET Data Format 115200 n 8 1 Operating Mode Transparent Network Survival Detecting Time 20 second 0x14 ZB 2550 P ZB 2551 P User Manual Ver1 0 March 2009 17 Ni 2 Applications 2 1 Operating Modes Interface Operating Modes Operating Mode 1 Transparent Serial Port Operating Mode 2 Packet RS 232 RS 485 Operating Mode 3 Packet Addressable Operating Mode e Transparent Original packet will be broken down into many small packets each small packet is 50 Byte Transparent mode lets you use the ZB 2550 P ZB 2551 P module like a router Maximum original packet size 1s 200 Byte Original packet must not more than 200 Byte e g 01M 4 Byte 01M 01M lt De a SA e 9 wen 01M Addross 02 ZB 2551 E Node ID 0x0002 B 28 2550 401M 01M ZB DIO ZB 2551 ZB AIO Node ID 0x001F Addross 03 ZB 2550 P ZB 2551 P User Manual Ver1 0 March 2009 18 Ste Packet Original packet won t be broken down into small packets Bring original packet into a ICP DAS packet The size of a ICP DAS packet 1s 200Byte Maximum original packet size 1s 200 Byte ICP 01M DAS 01M ZB 2551 Address 01 Node ID 0x0005 01M U amp W
3. B 2550 Net ID 02 f _ Barcode reader ZB 2551 Net ID 03 Barcode 78 2551 ZB 2550 Net ID 02 Syntax ADDRxxx i Delimiter character ADDR The ADDR is your ZB 2551 P Node ID XXX XXX 1S your original packet ZB 2550 P ZB 2551 P User Manual Ver1 0 March 2009 22 2 3 ZigBee Network Groups Pan ID OxF FOO RF Channel 0x00 STAR Pan ID VOxABCD RF Channel 0x0E CLUSTER TREE ZB 2570 ZB 2550 ZB 2571ZB 2351 ZB 25310 ZB DIO ZB ATO MESH Pan ID 0xAABB RF Channel 0x04 A Work Network Runing on the same Pan ID and RF Channel ZB 2550 P ZB 2551 P User Manual Ver1 0 March 2009 23 Xe 0 Original packet gt 50 Byte gt No Delay Original packet gt 50 100 Byte gt Delay 50ms Original packet gt 100 150 Byte gt Delay 100ms Original packet gt 150 200 Byte gt Delay 150ms Original packet gt 200 Byte gt N A If original packet size is greater than 50 Byte most of the time Operating Mode Packet is the most suitable If you want to transmit more than 200Byte one packet and high speed rate please order a advanced ZigBee Converter ZB 2570 and ZB 2571 If original packet size is less than 50 Byte most of the time Operating Mode Transparent is the most suitable If original packet size is greater than 50 Byte most of the time Operating Mode Packet is the most suitable If you want to transmit more than 200 Byte one Packet or
4. B 2550 ZB 2551 ZB 2050P ZB 2551P Antenna 10 30VDC ZB 2550P ZB 2551P ZB 2550 P ZB 2551 P User Manual Ver1 0 March 2009 9 1 5 Wire Connection Serial Port RS 232 Controller RS 232 Female CA 0915 Remote l O RS 232 Male CA 0910N ZB 2550 P ZB 2551 P User Manual Ver1 0 March 2009 10 Serial Port RS 485 Controller 10 30 Vpc Remote l O 10 30 Voc GND ZB 2550 P ZB 2551 P User Manual Ver1 0 March 2009 11 Ste 1 6 Quick Start 1 Before configuring the ZigBee converter adjust the switch to the ZBSET position then re boot power off on the module After configuration is complete adjust the switch to the RUN position then re boot power off on the module acd RUN Cm 2 When the following screen is displayed click on the OK button Fe ish zi Bali m ZB a g Fa EET jo Exit ee 2 Ss A nork z Qe OO ee 24 RS232 O ZigBee er Factory setting ZB 2550 P ZB 2551 P User Manual Ver1 0 March 2009 12 3 Click on the Connect button ZB 2550 P 2551 P Utility v310 The Data Format of ZESET Position is 115200 n 5 1 3 Single click the button to continue setting Connect 2 Choosing an interface Power off on ZBSET RUN Dr 1 Switch the DIP Switch to ZESET Position 4 Please select the COM Port on your PC The Data Format of ZBSE
5. T Pos COM Port COMI v Format 115200 n 8 1 ZB 2550 P ZB 2551 P User Manual Ver1 0 March 2009 13 Ste 5 Click on the Config button to configure setting for the ZigBee Converter ZB 2550 P ZB 2551 P e g ZB 2551 P Transparent Module Type H 2551 P4 Version 01 00 ZB 2551 Fan ID Ox0000 OxF FFF FF 00 Address 01 Node ID 0x0005 Node ID 0x0000 0xFFFF 0010 01M oe Me RF Channel Network Survival Detecting HE i 01M TimetOx00 OxFF in 15 f rden d 7B 2551 E x TP Operating Mode Node ID 0x0002 Data Format 115200 n 8 1 TH Address 03 ZB 2551 Node ID 0x00 1F Connect OF i ZB 2551 Address 01 Node ID 0x0005 a M 2 401M 26 2550 Address 02 ZE 2551 E Node ID 0x0002 01M ZB 2551 Node Ib Ox001F Default Completed ZB 2550 P ZB 2551 P User Manual Ver1 0 March 2009 14 Ste 7 After ZigBee module configuration has been successfully established Now adjust the switch to the RUN position then re boot power off on the module Leverage the power of your data Make it work for you RS 232 T c H faa RUN RS 45S 8 Click Default button to load factory default parameters if you want to load factory default setting of ZigBee Module version 11 00 Transparent Module Type ZH 2551P Pan ID Ox0000 OxF FFF FF OO Node ID x00I 0xEFFEy 0010 RF Channel o 01M Network Survival Det
6. XS ZB 2550 P ZB 2551 P User Manual Warranty All products manufactured by ICP DAS are under warranty regarding defective materials for a period of one year beginning from the date of delivery to the original purchaser Warning ICP DAS assumes no lability for any damage resulting from the use of this product ICP DAS reserves the right to change this manual at any time without notice The information furnished by ICP DAS 1s believed to be accurate and reliable However no responsibility is assumed by ICP DAS for its use not for any infringements of patents or other rights of third parties resulting from its use Copyright Copyright 2007 by ICP DAS Co Ltd All rights are reserved Trademark The names used for identification only may be registered trademarks of their respective companies ZB 2550 P ZB 2551 P User Manual Ver1 0 March 2009 1 iF Table of Contents THI T OGUICTION sesser A 3 l i VOTE IN OMAN ON ee ee 4 12 EINES EN MEN een re ee ee 6 1 3 SPECI ICC IS in nee een 7 IA POC TD a0 een 9 1 WTOC ON CCT ON ee E s2 10 1 0 O I as coycaanfyseeaooigitiorcaosgeovriyhartcc A 12 Zigbee Addressing and Idenfi TI TS so o o 5 so s e5 5 s 5s se 16 427 DC SEINES een 17 APPULA ON oeiee 0012116610210006516115 2262100116 caiet 10075E7 nuna3140E 121001250 92100000511229215xe2 18 oud OCT OTIS Modes un ee uhren ee 18 o L 3 7 S c o ooocoocooocoo
7. Z 28 2550 Addross 02 ZB 2551 E Node ID 0x0002 ICP 01M DAS 01M B 26 2551 Node ID Ox001F Addross 03 e Packet Addressable Original packet won t be broken down into small packets For Non Addressable Device such as barcode reader Syntax ADDRxxx the ADDR is your ZB 2551 P Node ID Maximum original packet size is 200 Byte Original packet must not more than 200 Byte e g xxx 3 Byte Non Addressable Devices Packet Addressable gt Barcode reader 7B 2551 Node ID 0x0005 0002 xxx XXX NM PE lt gt gt s mrrrrre Barcode 2B 2551 P ZB 2550 reader Node ID 0x0002 E v 0002 Barcode 26 2551 ZB 2551 Node ID reader Node ID 0x001F ZB 2550 P ZB 2551 P User Manual Ver1 0 March 2009 19 See 2 2 Application Example Operating Mode 1 Transparent If you wish to convert the RS 232 RS 485 interface to ZigBee and the device is addressable such as the ICPDAS I 7000 M 7000 I 87k remote I O modules you can use the ZB 2551 slave to connect to these I O modules and use the ZB 2550 host to connect to your controller or PC If original packet size is less than 50 Byte most of the time this Mode is the most suitable RU 87P1 ZB 2551 Net ID 02 I 87k Net ID 03 7p 9554 ZB 2550 In some applications where the host controller needs to broadcast data to all RS 232 RS 485 devices and these devices receive data only no re
8. ecting La E Timeridx00 0xFF in 15 Forte 7E 2551 Le Operating Mode Node ID 0x0002 Data Format 115200 n 8 1 Address 03 Node ID 0x00 F Connect OF ZB 2550 P ZB 2551 P User Manual Ver1 0 March 2009 15 Zigbee Addressing and Identifiers e Node ID 0x0000 0xFFFF A 16 bit address that describes a Zigbee node Randomly assigned during network join ZB 2570 P ZB 2550 P always uses 0x0000 ZB 2571 P ZB 2551 P ranges 0x0001 OxFFFF ZB DIO ZB AIO ranges 0x0001 0x001F Resolve by stack 1n case of collision Included in all message to identify node Pan ID 0x0000 0xFFFF A 16 bit ID to identify the network Included in every packet A logical way to separate Zigbee networks running on same RF channel Defined during network formation by ZB 2570 P ZB 2550 P ZB DIO ZB AIO always uses OxFFOO or OxFFO1 RF Channel 1 of 16 RF channels Defined during network formation by ZB 2570 P ZB 2550 P Note A Work Network Runing on the same Pan ID and RF Channel e Network Survival Detecting Time ZB 2551 P will connect with Parent ZB 2550 P periodically to confirm the survival of network If t detects unsuccessfully and it process initialize network again to find a new parent ZB 2550 P ZB 2551 P User Manual Ver1 0 March 2009 16 vn 1 7 Default Settings Default settings for the ZB 2550 are as follows ZB Node ID 0x0000 ZB Pan ID 0xFF00 ZB Chamnel RF Channel 0x00 ZBSET Data
9. high speed rate please order a advanced ZigBee Converter ZB 2570 and ZB 2571 ZB 2550 P ZB 2551 P User Manual Ver1 0 March 2009 24 l n e Technical Support If you have problems about using the ZB 2000 series modules please contact ICP DAS Product Support Email Service icpdas com ZB 2550 P ZB 2551 P User Manual Ver1 0 March 2009 25
10. itivity 102 dBm Transmit power 12 dBm Network Topology Star Mesh and Cluster tree support Certification TUV ZCP Antenna 2 4GHz 3dBi Omni Directional antenna Transmission Range 100m 700m 100m 700m Models ZB 2550 ZB 2550P ZB 2551 ZB 2551P CPU 8 bit microcontroller EEPROM 128 KB 8 blocks each block has 256 bytes Data retention gt 40 years 1 000 000 erase write cycles Module Type Host Host Slave Slave COM 0 RS 232 TXD RXD and GND RS 232 TXD RXD and GND D SUB9 Female Non isolated D SUB9 Male Non isolated RS 485 D D internal ASIC self tuner Non isolated Data Bit 8 Parity Even Odd None Stop Bit 1 2 ZB 2550 P ZB 2551 P User Manual Ver1 0 March 2009 7 ZigBee Net State Green ZigBee RxD Yellow Power Red Models ZB 2550 ZB 2551 ZB 255IP Protection Power reverse polarity protection EMS Protection ESD Surge EFT Required Supply 10 VDC 30 VDC Voltage Power Consumption 0 5W 2W max 0 5W 2W max Connection 5 Pin 5 08 mm Removable Terminal Block Casing Plastic Flammability UL 94V 0 materials Dimensions 33 mm x 78 mm x 107 mm Wx Lx H Installation DIN Rail Operating 25 C 75 C Temperature Storage 40 C 80 C Temperature Relative Humidity 5 95 RH non condensing ZB 2550 P ZB 2551 P User Manual Ver1 0 March 2009 8 1 4 Block Diagram ZB 2050 ZB 255 Antenna 10 30V0C fs Z
11. k and is used to initialize and manage the data transmission routes The ZB 2551 Slave ZigBee router is responsible for transmitting receiving data from its child parent router or the host ICP DAS ZigBee products are designed for low data rates The main benefit of ICP DAS ZigBee products is that they can be used to define a general purpose self organizing mesh network which can be highly advantageous for industrial control The typical transmission range of the ICP DAS Zigbee ZB 2550 ZB 2551 converter is 100m and the ZB 2550P ZB 2551P is 700m ZB 2550 P ZB 2551 P User Manual Ver1 0 March 2009 4 Ni The transmission frequency range of the ZigBee converter 1s between 2 405 GHz and 2 48 GHz separated into 5 MHz sectors and provides 16 channels and 65536 Pan IDs 65535 network groups can be set The ZigBee converter includes a repeater module that can be used to increase communication range or prevent data loss if the connection is interrupted or becomes unstable Please refer to ZigBee converter other document for more information as following links http ftp icpdas com pub cd usbcd napdos zigbee zigbee_converter ZB 2550 P ZB 2551 P User Manual Ver1 0 March 2009 5 Xe 1 2 Pin Assignment ZB 2050 P ZB 2051 P 00000 0000 Ss ZB 2550 P ZB 2551 P User Manual Ver1 0 March 2009 6 Ste 1 3 Specifications Models ZB 2550 ZB 2551 ZB 255IP RF channels 16 Receive sens
12. sponse you can also use this mode ZB 2550 P ZB 2551 P User Manual Ver1 0 March 2009 20 Ni Operating Mode 2 Packet If you wish to convert the RS 232 RS 485 interface to ZigBee and the device is addressable such as the ICPDAS I 7000 M 7000 1 87k remote I O modules you can use the ZB 2551 slave to connect to these l O modules and use the ZB 2550 host to connect to your controller or PC If original packet size is greater than 50 Byte most of the time this Mode is the most suitable L nhi n M 7000 Net ID 02 Net ID 01 01 05 00 01 FF 00 Han lt RU 87P1 RU 87P1 Net ID 04 Net ID 03 01 05 00 01 FF 00 gZ M 7000 k Net ID 01 GQ I 4 il ef RU 87P1 RU 87P1 ZB 2550 4 jul M 87k In some applications where the host controller needs to broadcast data to all RS 232 RS 485 devices and these devices receive data only no response you can also use this mode ZB 2550 P ZB 2551 P User Manual Ver1 0 March 2009 21 Xe Operating Mode 3 Packet Addressable If the RS 232 RS 485 interface modules aren t addressable Add 5 ASCII characters to the header of the original request data from your controller then the remote device with the correct address will respond to it This mode is similar to that used in ICPDAS I 752N products T ZB 2551 Net ID 01 gt gt 0002 Xxx Barcode reader x Barcode reader ZB 2551 Z

Download Pdf Manuals

image

Related Search

ZB 2550(P)/ZB 2551(P)

Related Contents

Mikrowelle MD 11471 Nord.book  eCow pH Bolus User Guide  HP 12500 スイッチシリーズ  Automne 2006 - La Gazette de Prangins  MC08-31 Welding Fume Control FAQs  TP-Link TL-WN722N User's Manual  LG LDF8072ST Energy Guide  - De la Rosa Research  Radionomy - My Reader  Guide français de la sécurité alimentaire - CCI Saint  