Home

Functions Added to Smart Camera FQ2 Sensor Software

image

Contents

1. and then reconnect If you want to change the IP address change the network settings of the computer and then select using the procedure above If the list does not appear check if the LAN cable is correctly connected 2 7 Restoring a sensor connection 2 7 1 Related sections in manual 11 3 Basic Troubleshooting 2 2 Restoring the connection with a sensor lf a sensor on the same network in the Sensor list cannot be detected and you do not know the IP address of the sensor perform Re assign IP forcely This will forcibly change the sensor s IP address and connect the sensor gt Run Mode TF settings re assign IP forcely 1 Directly connect one to one with the sensor using the Touch Finder or the computer 2 Touch re assign IP forcely a This function can be used with Ver 1 84 or later sensors It cannot be used with any other sensors This function cannot be used for a connection over a router 5 5
2. To our customers July 2013 OMRON Corporation Industrial Automation Bisiness Company Functions Added to Smart Camera FQ2 Sensor Software Thank you for using OMROM products We have released a new version Ver 1 84 of the sensor software for the FQ2 Series of Smart Cameras The functions that have been added or changed in Ver 1 84 are described in this document Please use this document together with the manual Applicable Manuals Smart Camera FQ2 User s Manual Catalogue No Z326 E1 April 2013 Smart Camera FQ2 S4 User s Manual Catalogue No Z330 E1 April 2013 Smart Camera FQ2 CH User s Manual Catalogue No Z331 E1 October 2012 Contents 1 Summary of Additions and Changes in Sensor Software Ver 1 84 cccccssceccsseeeeceeeeeeceeeeeeseeseeesseeeeessaeeeessegeeenes 2 2 Derails of AGded Ghanged FUACHONS cssiconssaectosssacennatidinismcemsinarc anianeeasniacaiancareusatelavtiartovsnenteiaesheninasetarsbactiupiencauntinas 2 2 1 Setting the sensor in the Sensor list screen oo eee eecccseececeeeeeceeeeceeeeeceueeceeeeeseueessaeeeseueessaeeeseusesseeeesaneessgeeess 2 2 1 1 Related sections of manual ccesesentonsscticachixcteenccscecdbasisrvaeinecsasiedtuciesiseenasisadadieasrccdsasicedaebectusddancssdadiacusiedteesioncaees 2 e DOUG WAS SOM SOF N E E EN E E E E E A E E E E E E E 2 2 1 3 Sensor list Menu cic cicensenontencsosiianctceneenacandeaceushieavadeuadensuehineusdebedawseasacecetensjacsesdnccedahstass
3. anual sasievuarstocaveturavinavssarssdecgnesadunanierneeceans EAEE Ea AEON EE 4 2 5 2 Displaying a live freeze image in the Setup MOEC cccccccsseeeeceeeeeeceeeeesseeeeeseeeeessaeeeessageeessaeeeesaaes 4 2 0 1P address used in PO 9110 eee ee re ee ene Tn ro er AREENA REAA E ee ee ee eee 5 2 6 1 Related sections in manual sacatesceancenncvicsxiusastancduntiesihattessteoita sinkhole sdsebiesihattatsteoltasinketlastseiesidettusoucss 5 2 6 2 Selecting the IP address used in the PC Tool ccccccccseeeeeceeeeeeeeeeeeeseeeeeeseeeeesaeeeeessaueeessaeeeessaeeeesaaes 5 2 7 Restoring a sensor connection ai sicnenae taxis nede atetwsc tcusdedtdacten Medactsst sitiachian Ueda ttt ant eur Sakachideastaunn tetachiasantauteudledachabartauanine 5 2 7 1 Related sections in manual sccaincesie sick scsi ia crear nate asiisnictatessintrateasanat stot bal aarutsouisiaheinbntateatuteaient ctiialnaandieninetahatien 5 2 7 2 Restoring the connection with a sensor uidccinccsceeiectsdevlecsedusteien eiaveidvetaroodewiedsdaed pi dcuiacendeedodoncesieretdeens 5 1 5 1 Summary of Additions and Changes in Sensor Software Ver 1 84 The main changes and additions are as follows The Specify sensor screen and Search unreachable sensors screen have been combined into the new Sensor list screen The screen that appears in TouchFinder immediately after the power is turned on has been changed Changing from the Sensor monitor scre
4. eeuioccedsbatevsconioes 2 ey mame 210181 66 S 6 2 gee eee ee aiaa ee a em E 3 2 2 1 Related sections OF manual scceasiccdnenceencedenncbiwchandsdndanededioxtawdsastonudedeehacdsatdceedede hastbaenneedsde bachawniesGedewians 3 2e e AUDISI a E E cote are esas eet ose 3 2 2 3 Gensor connection Wall SCICCN uiscccivssractnrsensdonsiebsdetsieusdamssededeie dousanmsaudeiedensuspodssahededsieugdousabeiagsisandenesaes 3 2 3 Sensor monitor selector and WOOO Nath iret ccs ears sic ects rte tarde eshdlsocteatelter needle apte seis tveeelbed abarte tention ecateneeennte 3 2 3 1 Related sections in the manual bs stecdencasete noceadssascadeecaseadvs casnid acubegens ds naadeecatendva desaie ecebeddne s kode caseadveces 3 2 3 2 Changing the Run Mode Display se de asteaiies wincaleriseprivciasdalvnrts esieatissiesicdi ged onic gateadsleduanddalulndwgsalnbndndsdiindentiennd ties 3 2 4 Displaying sensor information in Multi sensor screen and Switch Sensor screen ceceeeeeeeceeeeeeeeeeeeeeeees 4 2 4 1 Related sections Of manual 2 cic ciccccniccsiccsdadacccatedssenecddaceasiadaeasededasedesennseandeassecelasaseneienevececaeareasdenasesesesaxe 4 2 4 2 Displaying sensor information in the screen when multiple Sensors are CONNECHEC cccceeeeeeee ees 4 2 5 Live freeze selection in the Setup MOC siisxcctesanscdeeceuseencesered ences scahebinesetactctiedescasieetasered doce eecduacaetelecceesattecsevedecees 4 25 1 Relked sections n m
5. en to the Single sensor screen Multi sensor screen or NG sensor screen is now possible Tool buttons have been added to the Multi sensor screen and NG sensor screen Sensor information can now be shown in the Multi sensor screen and Switch sensor screen The image that appears when the screen is switched from Run to Setup has been changed from live image to freeze image display Live image and freeze image buttons have been added to the Display screen The IP address used in the PC Tool can now be selected A function for restoring a sensor connection has been added 2 Details of Added Changed Functions 2 1 Setting the sensor in the Sensor list screen 2 1 1 Related sections of manual 7 5 Connecting to More Than One Sensor Setting the Sensors to Connect 12 1 Menu Tables The Specify sensor and Search unreachable sensors menus have been eliminated Equivalent settings can be configured in Sensor list 2 1 2 Setting the sensor Select the sensors that you want to connect to from the sensor list in the Touch Finder p gt Run Mode Sensor list 7 Touch the checkbox of the desired sensor to select it When a sensor s IP address setting is set to Auto the IP address is grayed out When set to Fixed the IP address is white Sensors for which a connection cannot be established are shown as follows l is added in front of the sensor name IP address error Cannot c
6. nformation of each of the sensors can be displayed in the Multi sensor screen and Switch sensor screen OFF IP Address or Sensor Name can be selected for the information displayed The default is IP Address 2 5 Live freeze selection in the Setup Mode 2 5 1 Related sections in manual 7 3 Display Functions Displaying a Live Image 7 3 Display Functions Displaying a Freeze Image The previous setting methods can also be used 2 5 2 Displaying a live freeze image in the Setup Mode The image when you change from the Run Mode to the Setup Mode is live image freeze image A live freeze selector button has also been added to the display settings E Display live image E Display freeze image 4 5 2 6 IP address used in PC tool 2 6 1 Related sections in manual 2 5 Setting Up Ethernet Connecting to Sensors from a Computer Using the PC Tool 2 6 2 Selecting the IP address used in the PC Tool The IP address subnet mask and default gateway of the computer used with the PC Tool is displayed If multiple IP addresses Network Interface Card NIC exist for the computer the IP address used in the PC Tool can be selected p gt Setup Mode Run Mode TF settings Ethernet IP Address 1 The list of IP addresses of the computer that can be used in the PC Tool appears the list to select the IP address 2 Touch All connected sensors disconnect briefly
7. nnected is not set The default for Auto sensor detection is ON gt OFF In the following cases the Sensor list screen does not appear and connection takes place in the previous manner The sensor to be connected is set Auto sensor detection is ON Specify sensor in the Startup display is ON 2 2 3 Sensor connection wait screen When sensor connection processing starts the sensor connection wait screen appears If the sensor cannot be recognized or you want to change the communication setting press the Sensor List button For the sensor list refer to Setting the sensor in the Sensor list screen 2 3 Sensor monitor selector and toolbox 2 3 1 Related sections in the manual 6 2 Configuring the Run Mode Display 7 3 Display Functions Automatically Changing to the Display for Any Sensor with an NG Result 2 3 2 Changing the Run Mode Display Tool buttons have been added to the Multi sensor screen and NG sensor screen Sensor monitor can be set to Single sensor Multi sensor or NG sensor 3 5 2 4 Displaying sensor information in Multi sensor screen and Switch sensor screen 2 4 1 Related sections of manual 3 1 Selecting a Sensor for Configuration 7 5 Connecting to More Than One Sensor Selecting the Display When More Than One Sensor Is Connected 2 4 2 Displaying sensor information in the screen when multiple sensors are connected The i
8. onnect because there is a sensor outside the subnet with the same IP address Change the sensor s network settings It Unknown device Cannot recognize the sensor It may be a non FQ device Il No response No response Check if the Ethernet cable is connected correctly If sensors on the same network do not appear in Sensor list it may be taking a long time to detect them Refresh the list The checkbox of a sensor that is not connected can be selected When the sensor is in a connectable state it will connect 2 1 3 Sensor list menu The Sensor list menu consists of the following items Network settings Change the sensor s network settings Switch sensor Apply the connection settings and change the displayed sensor Delete sensor Delete a sensor from the sensor list Communication test Check communication with the sensor Add sensor Add a fixed IP address to the sensor list Refresh list Update the sensor list with the latest information Menu items that cannot be used due to the sensor version or status are not shown 2 5 2 2 Startup display 2 2 1 Related sections of manual 1 3 Startup Display and Display Elements Startup Display The Auto connect screen and menu are eliminated When a sensor is disconnected the Sensor list screen appears 2 2 2 Startup Display The Sensor list screen always appears when Auto sensor detection is OFF and the sensor to be co

Download Pdf Manuals

image

Related Search

Related Contents

Naii”naー 施工説明書  取扱説明書[フォトパネル 02]  Bedienungsanleitung - Wiki Karat  Oro/Plata/Bronce - Pinturas Blatem  Cypress CY7C1347G User's Manual  ABE12KX USER MANUAL  AuG Z A3  Sony VGF-CP1 Quick Reference Guide  

Copyright © All rights reserved.
Failed to retrieve file