1. CHECK Fence voltage questionable Inspect fence and do maintenance ALARM If lit permanently the fence dropped below acceptable voltage levels Flashing intermittently in conjunction with the HIGH POWER indicator indicates severe loading on the fence HI GH POWER An indication that the output energy of the energizer is being doubled due to fence loading Continuous operation of the HIGH POWER indicator is to be avoided Either there is excessive vegetation or fault on the fence The HIGH POWER indicator will only flash briefly if a short is presented to the energizer The energizer would detect this as a potential head body shock that can be lethal and reduce or if installer configured stop any further energy from exciting the fence 11 PDF created with pdfFactory trial version www pdffactory com MERLIN STEALTH M113S what the Energizer lights indicate WHAT THE ENERGI ZER LI GHTS I NDI CATE Condition Power On Fence Fence Fence Gate Light High Power Service Remarks Light Light Good Check Alarm 1 or 2 Light Light SLOW Fence on FENCE GOOD ON ON FLASH OFF OFF OFF OFF OFF working properly Fence off FENCE OFF ON OFF OFF OFF OFF OFF OFF OFF working properly Fence turned off with alarm ee ON oni FAST condition FLASH active MAINS FAILURE OFF System on battery power LOW VOLTAGE SLOW ar i tet MODE FLASH low volta
2. After an alarm occurs Switch the unit off with the Nemtek tab or remote key switch This will silence the siren if it has not already timed out internal beeper and will switch the strobe off One of the alarm lights will be flashing or remain lit to indicate the source of the alarm A permanently lit indicator notifies the user that the fault no longer exist In the latter case simply turning the energizer On again will clear the memory condition A flashing alarm light illustrates that the fault condition persist In this case rectify the condition which caused the alarm To reset and clear the memory condition turn the energizer On and Off and On again Only if the alarm condition is resolved will the energizer operate without alarm activation OPERATION WITH A KEYPAD The energizer may be operated via a remote keypad In this case the Nemtek tab becomes optional Installer programmable In order to provide different access levels to the energizer and its functions different types of user are defined A master user has full control of the energizer and may bypass different alarm functions The master user may change the pin identification number for all the users There is only one master user with a default PIN of 1234 user 0 There are three normal users and three reset users A normal user may turn the energizer On Off and reset alarm conditions but not change the functionality of the energizer User 1 2 and 3 For PDF
3. key To cancel the bypass repeat the same sequence of keys TURN THE GATE CHI ME ON Gate1 IY I CIC G OI CI Enter your PIN master only and the key enter the digit 2 enter the digit 8 enter the digit 1 then press the key If the chime is on the keypad will beep three times if the gate opens and twice if it closes TURN THE GATE CHI ME OFF Gate1 ae ee 5s ere Cs EP Enter your PIN master only and the key enter the digit 2 enter the digit 8 enter the digit 2 then press the key No audible indication of gate opening or closing TURN THE GATE CHI ME ON Gate2 JOP JO VJ WA I Enter your PIN master only and the key enter the digit 2 enter the digit 8 enter the digit 3 then press the key If the chime is on the keypad will beep three times if the gate opens and twice if it closes TURN THE GATE CHI ME OFF Gate2 OVJ Enter your PIN master only and the key enter the digit 2 enter the digit 8 enter the digit 4 then press the key No audible indication of gate opening or closing BYPASS THE SERVI CE ALARM eA AA A CA Enter your PIN master only and press the key enter the digit 9 then press the key The SERVI CE ALARM light will start flashing slowly to confirm that the service alarm is bypassed To cancel the bypass repeat the same sequence of keys The energizer will indicate a service alarm if the battery voltage is low PDF created with pdfFactory trial version www pdffact
4. 0 PINis 1234 AFTER AN ALARM OCCURS CJL POCO A a Enter your PIN all users and press the key This will silence the buzzer and siren It will switch the fence off One of the ALARM lights will flash or stay lit to indicate the source of the alarm A flashing indicator illustrates that the fault condition persists A permanently lit PDF created with pdfFactory trial version www pdffactory com MERLIN STEALTH M113S Using your KEYPAD indicator notifies the user that the fault no longer exists In the latter case simply turning the energizer on again will clear the memory condition If the flashing alarm condition cannot be resolved the alarm will be activated irrespective of the number of times the unit is turned On or Off The Master user can bypass alarm conditions A reset user will only reset the alarm outputs and not change the On Off state of the energizer CHANGE THE VOLTAGE ON THE FENCE AEAU PE a Enter your PIN master only and press the key enter the digit 3 then press the key When the fence is on and in low voltage mode the red ON light will flash The red ON light will stay permanently lit if the fence is in high voltage mode Use the low voltage mode when children are in the fence vicinity BYPASS THE FENCE ALARM Pe a a Le Lee E Enter your PIN master only and press the key enter the digit 1 then press the key The FENCE ALARM light will start flashing slowly to confirm the fence alarm is bypass
5. GROUP OF COMPANIES MERLIN STEALTH M113S Electric Fence Energizer NEMTEK ay M113S Users Manual Revision 1 0 Date 29 January 2007 PDF created with pdfFactory trial version www pdffactory com MERLIN STEALTH M113S Table of Contents FOREWORD pisia ninais E a 3 GUARA N TE Eariri E A E T 4 INTRODUCT ONirccsonccinnananiamianne 5 OPERATION WITHOUT A KEYPAD sscisissietecmahstetediinntosndviaciasscaeerenedias 5 OPERATION WITH A KEYPAD casectectinnscteletaaracssmensienicarsrneeeietinedvenss 5 USING YOUR KEYPAD KEYPAD sicsnisarisiriivnarinoaisaniaa an 6 10 PENCE INDICATOR Ll GPS ccvestvacencsssnassncasendaimmsesteadaninrkeccntnadoeals a 11 WHAT THE ENERGIZER LIGHTS INDICATE siscctesscuccetsieanscescccetnsene 12 WHAT THE KEYPAD LIGHTS INDI CAT E tcccscsnctrcinccinescessicadaatetaneiecetye 13 DOCUMENT REVISION HIS ORY sccetessassensret snceseentenseradcaisiiieincenacanaye 14 No user serviceable parts inside the energizer PDF created with pdfFactory trial version www pdffactory com MERLIN STEALTH M113S Foreword FOREWORD The Merlin Range of energizers has evolved over the past fifteen years The energizers are designed to comply with the latest international specifications In order to offer some product flexibility the embedded software in the energizers may change The latest version of documentation and energizer features can be viewed on our website at www nemtek com The M113S Energizer has patented energy control an
6. be increased or decreased by pressing and holding the 1 or 7 keys respectively The key pad will beep while the indicator brightness is changing No user PIN is required for this operation 10 PDF created with pdfFactory trial version www pdffactory com MERLIN STEALTH M113S Fence I ndicator Lights FENCE I NDI CATOR LIGHTS The M1135 energizer monitors the fence with every pulse A finite amount of energy is used to excite the fence Depending on the current magnitude of a fence pulse a second pulse may be used to excite the fence and effectively double the output energy The occurrence of the second pulse is indicated by the illuminating of the HIGH POWER indicator Under normal fence operating conditions the GOOD indicator should flash once a second As the fence becomes loaded due to excessive vegetation or moisture the Check indicator may start flashing If the loading becomes severe the HIGH POWER indicator will also start flashing and possibly the ALARM indicator as well When this occurs the voltage on the fence may change considerably because the available output energy has doubled The fence indicator lights may cycle between ALARM CHECK and GOOD as the effectiveness of the fence is maintained Should the fence loading be such that the fence voltage is insufficient to be a deterrent then the ALARM indicator will remain lit or have a fast flash and the alarm outputs if enabled will activate FENCE1L GOOD Fence voltage acceptable
7. created with pdfFactory trial version www pdffactory com MERLIN STEALTH M113S Using your KEYPAD security reasons they have no default codes and must be assigned by the master user A reset user may only reset the alarms but not change the On Off state of the energizer User 4 5 6 For security reasons they have no default codes and must be assigned by the master user The embedded Linux platform will be made commercially available during 2007 that will provide connectivity to the energizer and a history of all events including user intervention The three different users in the normal operators allows for three eight hour shifts to be monitored The energizer will restore its condition to its previous state should there be a total power failure i e mains failure and battery flat Note that the Gate inputs are active even when the energizer is switched off Use the Gate Bypass function if these inputs are to be ignored USING YOUR KEYPAD SWITCH THE FENCE ON OFF Master Normal User KAN A A Aaa To switch the fence On or Off enter your four digit PIN followed by the key Ifthe red ON light is lit or flashing the fence is energized e Don t pause for more than 5 seconds while entering the digits or the control panel will reject your PIN number e f you make a mistake while entering your PIN press the key and start again e An incorrect PIN will cause the control panel to beep 5 times The default master User
8. d safety features Refer any questions and special requirements to suitably trained installers Electric fencing can be lethal Avoid head contact with the fence Get the installer to explain the options of current limiting resistors the enhanced safety features of the M113S and the low voltage operation of the energizer PDF created with pdfFactory trial version www pdffactory com MERLIN STEALTH M113S Guarantee GUARANTEE The Merlin energizer manufactured by IO Tech Manufacturing Pty Ltd is guaranteed for a period of one year from date of sale against defects due to faulty workmanship or materials 1O Tech Manufacturing Pty Ltd will at its discretion either repair or replace a product that proves to be defective 10 Tech Manufacturing Pty Ltd guarantees that the product when properly installed and used in line with the specification as determined by 1O Tech Manufacturing Pty Ltd from time to time will execute its function of generating a suitable potential 10O Tech Manufacturing Pty Ltd does not guarantee that the operation of the product will be uninterrupted and totally error free Faulty units must be returned to Nemtek Units 4 amp 5 64 Vervoer Street Kya Sand Randburg Gauteng South Africa OR Nemtek Security Warehouse Unit 4 Meadowdale Park Cnr Herman amp Dick Kemp Roads Meadowdale Edenvale Gauteng South Africa The buyer shall pay all shipping and other charges for the return of the product to Nem
9. e gate alarm is immediate MAKE THE GATE ALARM DELAYED Both Gates a Er Enter your PIN master only and press the key enter the digit 2 followed by the digit 4 then press the key The default gate delay is 4 minutes MAKE THE GATE ALARM DELAYED Gate 1 OOOO Er EF Enter your PIN master only and press the key enter the digit 2 followed by the digit 4 followed by the digit 1 then press the key The default gate delay is 30 seconds MAKE THE GATE ALARM DELAYED Gate 2 DOGO DD Enter your PIN master only and press the key enter the digit 2 followed by the digit 4 followed by the digit 2 then press the key The default gate delay is 30 seconds BYPASS THE GATE ALARM Gate 1 and Gate 2 COCICID OCOD Enter your PIN master only and press the key enter the digit 2 then press the key The GATE ALARM light will start flashing slowly to confirm that the gate alarm is bypassed To cancel the bypass repeat the same sequence of keys BYPASS THE GATE ALARM Gate 1 JVV Enter your PIN master only and press the key enter the digit 2 followed by the digit 1 then press the key To cancel the bypass repeat the same sequence of keys PDF created with pdfFactory trial version www pdffactory com MERLIN STEALTH M113S Using your KEYPAD BYPASS THE GATE ALARM Gate 2 VYJ OO Bae Enter your PIN master only and press the key enter the digit 2 followed by the digit 2 then press the
10. ed To cancel the bypass repeat the same sequence of keys BYPASS THE SIREN AND STROBE LI GHT SILENT ALARM kA AE AE ae Enter your PIN master only and press the key enter the digit 4 then press the key The beeper in the control panel will still be active UN BYPASS THE SI REN AND STROBE LI GHT Y I VY V IY W Enter your PIN master only and press the key enter the digit 7 then press the key MAKE THE GATE ALARM I MMEDI ATE Both Gates a i a a T Co Enter your PIN master only and press the key enter the digit 2 followed by the digit 7 then press the key The GATE ALARM light will start flashing with a cadence of one flash every 5 seconds to confirm the gate alarm is immediate PDF created with pdfFactory trial version www pdffactory com MERLIN STEALTH M113S Using your KEYPAD MAKE THE GATE ALARM I MMEDI ATE Gate 1 CPU ICI SI I GD G9 Enter your PIN master only and press the key enter the digit 2 followed by the digit 7 followed by the digit 1 then press the key The GATE ALARM light will start flashing with a cadence of one flash every 5 seconds to confirm the gate alarm is immediate MAKE THE GATE ALARM I MMEDI ATE Gate 2 OOOO ODMOOIE Enter your PIN master only and press the key enter the digit 2 followed by the digit 7 followed by the digit 2 then press the key The GATE ALARM light will start flashing with a cadence of one flash every 5 seconds to confirm th
11. ence alarm switched off FAST l GATE OPEN FLASH Gate is open SLOW GATE BYPASS FLASH Gate alarm switched off GATE TAS Appropriate gate input is IMMEDIATE pes in immediate mode SECONDS 1 SHORT SILENT FLASH Siren or strobe light not ALARM EVERY 5 activated by alarm SECONDS GATE2 Gate2 LONG Gate 2 closed fence in CONTROLS FLASH low voltage mode FENCE EVERY 5 Gate 2 open fence in VOLTAGE POND high voltage mode ALARM MEMORY ON ON ON Old alarm Enter PIN SERVI CE SLOW ALARM FLASH BYPASS SERVI CE FAST No main battery flat ALARM FLASH faulty fuse PDF created with pdfFactory trial version www pdffactory com 13 MERLIN STEALTH M113S Document Revision History DOCUMENT REVISION HISTORY Revision 1 0 29 January 2007 End of document PDF created with pdfFactory trial version www pdffactory com
12. ge Check Fence SLOW Remove FENCE CHECK FLASH MAY FLASH vegetation FAST Problem on FENCE ALARM FLASH MAY FLASH ferice SLOW Fence alarm FENCE BYPASS FLASH switched off FAST GATE OPEN FLASH Gate is open SLOW Gate alarm GATE BYPASS FLASH switched off Appropriate GATE nal gate input is in IMMEDIATE EVERS immediate SECONDS mode 1 SHORT n ae SILENT ALARM FLASH EVERY aled i 5 SECONDS y alarm Gate2 a 2 o GATE2 LONG eae CONTROLS FLASH ee ie FENCE VOLTAGE EVERY 5 fence in E h SECONDS g voltage mode No mains BATTERY VOLTAGE LOW OFF Faulty fuse Old alarm ALARM MEMORY ON ON ON Enter PIN SERVICE ALARM Service alarm BYPASS aa switched off No mains SERVICE ALARM Lie battery flat faulty fuse 12 PDF created with pdfFactory trial version www pdffactory com MERLIN STEALTH M113S what the Keypad lights indicate WHAT THE KEYPAD LI GHTS I NDI CATE Gate ee Power n Fen rvi Condition OWS od a yas Light 1 Se lt Remarks Light Light Light Light or 2 Light FENCE GOOD ON ON ON OFF OFF gir Tence gn working properly Fence off working FENCE OFF ON OFF OFF OFF OFF OFF properly SLOW Fence turned off with FENCE HPE ON FLASH a alarm condition active MAINS FAILURE OFF System on battery power LOW SLOW Energizer switched to low VOLT ABE FLASH fence voltage MODE g FENCE FAST ALARM OFF FLASH Problem on fence FENCE SLOW BYPASS FLASH F
13. ory com MERLIN STEALTH M113S Using your KEYPAD MANUAL BATTERY TEST CJC OC ICI GIGI Enter your PIN master only and press the key enter the digit 6 then press the key The keypad will beep four times indicating the battery test has started This test disables the mains input for 20 minutes and monitors the battery voltage If the battery voltage falls below an acceptable level during this test the battery service light will come on provided the bypass is not enabled and indicates the battery needs replacing It is advisable to have the energizer running in High Voltage mode during this test It is advisable to test battery condition at least twice a year If the auto battery test feature is enabled by the installer the timing sequence will be re initiated CHANGI NG A USER PIN meen DDD adi zey E New PIN New PIN L AEA A AE Enter your master PIN press the key enter the digit 0 then press the key Enter the user number 0 6 and push the key User number 0 is the master PIN that has system configuration rights i e bypass of alarm conditions etc Enter that user s new PIN and press the key Enter the new PIN again and press the key If the new PIN is accepted the control panel will beep four times If you make a mistake while programming or if the system rejects the new PIN the control panel will beep five times ALTERING THE KEY PAD I NDI CATOR BRIGHTNESS The brightness of the keypads can
14. tek or Nemtek Security Warehouse LIMITATION OF GUARANTEE The guarantee does NOT apply to defects resulting from acts of GOD modifications made by the buyer or any third party misuse neglect abuse accident and mishandling EXCLUSIVE REMEDIES The remedies provided herein are IO Tech Manufacturing Pty Ltd s sole liability and the buyer s sole and exclusive remedies for breach of guarantee 1O Tech Manufacturing Pty Ltd shall not be liable for any special incidental consequential direct or indirect damages whether based on contact tort or any other legal theory The foregoing guarantee is in lieu of any and all other guarantees whether expressed implied or statutory including but not limited to warranties of merchantability and suitability for a particular purpose PDF created with pdfFactory trial version www pdffactory com MERLIN STEALTH M113S Introduction INTRODUCTION The energizer should ideally be operated by means of a remote keypad This enables the user to have access to many energizer features and offers the greatest security It can however be operated by means of a Nemtek tab or a remote on off switch OPERATION WITHOUT A KEYPAD Turning the energizer On Off Unless the feature has been disabled by the installer the energizer can be turned On or Off by holding the Nemtek plastic tab over the corresponding logo on the fascia of the unit Remove the tab on noticing the energizer turning On or Off