Home

CJ1W-IC/II

image

Contents

1. e Contact your OMRON representative for further details and applicable conditions for these standards V O Control Unit Mounted on CPU Rack when Connecting Expansion Racks Current Product name Specifications consumption A Standards 5V 24 V CJ series I O Control Unit Mount one VO Control Unit on the CPU Rack when connecting one or e more Expansion Racks E Connecting Cable CS1W CNOO3 Expansion Connecting Cable 0 02 CJ1W IC101 UC1 N L CE l i Connected Unit CU1W 11101 I O Interface Unit ie Mount to the right of the CPU Unit Note Mounting the I O Control Unit in any other location may cause faulty operation I O Interface Unit Mounted on Expansion Rack Current Product Name Specifications consumption A Standards 5V 24 V 13 CJ series I O Interface Unit One I O Interface Unit is required on each Expansion Rack Connecting Cable CS1W CNLILI3 Expansion Connecting Cable 0 CJ1W 11101 UC1 N L CE Mount to the right of the Power Supply Unit Note Mounting the I O Interface Unit in any other location may cause faulty operation Accessories CJ1W IC101 I O Control Unit There is no accessory for the I O Control Unit Unit CJ1W 11101 I O Interface Unit The following accessories come with I O Interface Unit Item Specification End Cover CJ1W TER0O1 necessary to be mouned at the right end of CPU Rack End Plate PFP M 2 pcs External Interface 1 O Control Unit
2. e Mounting and setting procedure e Remedies for errors e Also refer to the Software User s Manual W473 An introduction to the entire NJ series system is provided along with the following information on a Controller built with an NJ501 CPU Unit e Features and system configuration e Introduction NJ series CPU Unit Hardware User s Manual wW e Part names and functions NJ501 LUUULI 909 e General specification pecifications e Installation and wiring e Maintenance and inspection Use this manual together with the NJ series CPU Unit Software User s Manual Cat No W501 OMRON Terms and Conditions Agreement Read and understand this catalog Please read and understand this catalog before purchasing the products Please consult your OMRON representative if you have any questions or comments Warranties a Exclusive Warranty Omron s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron or such other period expressed in writing by Omron Omron disclaims all other warranties express or implied b Limitations OMRON MAKES NO WARRANTY OR REPRESENTATION EXPRESS OR IMPLIED ABOUT NON INFRINGEMENT MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE Omron further disclai
3. 1 O Interface Unit CJ1W 1IC101 CJ1W 11101 Output connector for J P 7L Input connector for Output connector for I O Connecting Cable I O Connecting Cable I O Connecting Cable OMRON CJ1W IC II Connecting Expansion Racks CS CJ series I O Connecting Cables are used to connect the CPU Rack and Expansion Racks CS CJ series I O Connecting Cables The CS CuJ series I O Connecting Cables have connectors with a simple lock mechanism are used to connect the CPU Rack to an Expansion Rack or to connect two Expansion Racks CS CJ series I O Connecting Cables n Model number Cable length CS1W CN313 0 3m CS1W CN713 0 7m CS1W CN223 2m CS1W CN323 3m CS1W CN523 5m CS1W CN133 10m CS1W CN133 B2 12m e Install the Racks and select I O Connecting Cables so that the total length of all 1 O Connecting Cables does not exceed 12 m e The following diagram shows where each I O Connecting Cable must be connected on each Rack The Rack will not operate if the cables aren t connected properly The up direction is towards the CPU Unit and down is away from the CPU Unit CPU Rack Expansion Rack Power Supply Unit I O Interface Unit Usage Precautions e CJ1W IC101 I O Control Unit is connected directly to the CPU Unit CJ1W 1I1101 I O Interface Unit is connected directly to the Power Supply Unit e The number of Expansion Racks that can be connected depends on the CPU Unit Refer to the SYSMAC NJ series CPU Unit
4. COMPANIES SHALL NOT BE LIABLE FOR SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS WHETHER SUCH CLAIM IS BASED IN CONTRACT WARRANTY NEGLIGENCE OR STRICT LIABILITY Further in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted Suitability of Use Omron Companies shall not be responsible for conformity with any standards codes or regulations which apply to the combination of the Product in the Buyer s application or use of the Product At Buyer s request Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product machine system or other application or use Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer s application product or system Buyer shall take application responsibility in all cases NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS AND THAT THE OMRON PRODUCT S IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTE
5. Hardware User s Manual Cat No W500 CJ Series Programmable Controllers Operation Manual Cat No W393 or CJ series CJ2 CPU Unit Hardware User s Manual Cat No W472 for details e Use a CS Series I O Connecting Cable CS1W CNLJLJ3 to connect an Expansion Rack e Install the Racks and select I O Connecting Cables so that the total length of all 1 O Connecting Cables does not exceed 12m e When using an I O Connecting Cable with a locking connector be sure that the connector is firmly locked in place before using it e Attached the enclosed cover to the I O Connecting Cable connector on the I O Interface Unit when it is not being used to protect it from dust OMRON CJ1W IC II Dimensions Unit mm 1 O Control Unit CJ1W 1C101 Note Weight 70 g max I O Interface Unit CJ1W 11101 Note Weight 130 g max including End Cover CJ1W IC II Related Manuals SYSMAC CJ Series CJ1H CPULILIH R CJ1G H CPULILIH ae CJ1G CPUDIDIP CJ1G CPUCO W393 Provides an outlines of and describes the design installation maintenance CJ1M CPUOO and other basic operations for the CJ series PLCs Programmable Controllers Operation Manual Describes the following for CJ2 CPU Units e Overview and features CJ series CJ2 CPU Unit Hardware User s Manual e Basic system configuration CJ2H CPU6L EIP W472 e Part nomenclature and functions CJ2H CPUEL
6. CJ series O Control Unit I O Interface Unit CJ1W IC II CSM_CJ1W IC II_DS_E_2_1 Expand CJ NJ series with These Units e To expand a CJ NJ series Controller connect an I O Control Unit to the CPU Rack and I O Interface Unit to the Expansion Rack and connect the two Units with I O Expansion Cable CJ1W 1C101 Features e Rack mountable Units enable expanding Controller capacity even when space is limited e Easy to use connectors enable quick expansion without any settings System Configuration CJ1W 11101 The I O Control Unit is connected directly to the CPU Unit If it is not immediately to the right of the CPU Unit correct operation may not be possible The I O Interface Unit is connected directly to the Power Supply Unit If it is not immediately to the right of the Power Supply Unit correct operation may not be possible Power CPU Unit CJ1W IC101 Supply Unit E I O Control Unit CPU Rack I O Connecting Cable CJ1W 11101 I O Interface Unit Power Supply Unit Expansion Rack I O Connecting Cable CJ1W 11101 I O Interface Unit Power Supply Unit S D lol le Q2 i laad OMRON CJ1W IC II Ordering Information International Standards e The standards are abbreviated as follows U UL U1 UL Class Division 2 Products for Hazardous Locations C CSA UC cULus UC1 cULus Class Division 2 Products for Hazardous Locations CU cUL N NK L Lloyd and CE EC Directives
7. M Programmable Products Omron Companies shall not be responsible for the user s programming of a programmable Product or any consequence thereof Performance Data Data presented in Omron Company websites catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty It may represent the result of Omron s test conditions and the user must correlate it to actual application requirements Actual performance is subject to the Omron s Warranty and Limitations of Liability Change in Specifications Product specifications and accessories may be changed at any time based on improvements and other reasons It is our practice to change part numbers when published ratings or features are changed or when significant construction changes are made However some specifications of the Product may be changed without any notice When in doubt special part numbers may be assigned to fix or establish key specifications for your application Please consult with your Omron s representative at any time to confirm actual specifications of purchased Product Errors and Omissions Information presented by Omron Companies has been checked and is believed to be accurate however no responsibility is assumed for clerical typographical or proofreading errors or omissions 2014 9 In the interest of product improvement specifications are subject to change without notice OMRON Corporatio
8. ms all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right c Buyer Remedy Omron s sole obligation hereunder shall be at Omron s election to i replace in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof the non complying Product ii repair the non complying Product or iii repay or credit Buyer an amount equal to the purchase price of the non complying Product provided that in no event shall Omron be responsible for warranty repair indemnity or any other claims or expenses regarding the Products unless Omron s analysis confirms that the Products were properly handled stored installed and maintained and not subject to contamination abuse misuse or inappropriate modification Return of any Products by Buyer must be approved in writing by Omron before shipment Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components circuits system assemblies or any other materials or substances or environments Any advice recommendations or information given orally or in writing are not to be construed as an amendment or addition to the above warranty See http www omron com global or contact your Omron representative for published information Limitation on Liability Etc OMRON
9. n Industrial Automation Company http www ia omron com c Copyright OMRON Corporation 2014 All Right Reserved

Download Pdf Manuals

image

Related Search

CJ1W IC/II cj1w ii101 cj1w ic101

Related Contents

Samsung SM-G530FZ Инструкция по использованию  Dénicher des fournitures vertes : le parcours du combattant  Samsung GT-S7350 User Manual  BIOSTAT® CultiBag RM 200  Sony MEX-BT3100P Marketing Specifications  EVA\EVAHL Back Pack User Manual  Canopy Rangehood - Appliances Online  Otterbox HTC One X Commuter  Microsoft K04-00001 User's Manual    

Copyright © All rights reserved.
Failed to retrieve file