1. Auto Manual switching working mode to automatic or manual We choose option by releasing chosen key 2 or gt when proper option is displayed OPERATION MANUAL BD TL 19 15 Permanent tare memory PT The scale can store up to 10 tare values in memory that can be later recalled The option enables gross weight measurement pieces quantity of product in for eg container of known weight and then readout of calculated net weight pieces quantity 1 To save permanent tare value into memory put object eg empty container on pan and press gt PT Below screen will be displayed MAXIS CZD 20E NET _O 7 2 v Wt Ptare S ave DATA E 2 In lower section display successive tare memory numbers will appear from tare I to tare 10 By using ENTER key user can select proper tare memory number where actual weight value is saved To recall saved earlier tare value press and hold PT Successive tare numbers and their values will display Releasing PT key chooses actually displayed tare 20 OPERATION MANUAL BD TL 16 Products data library lt gt MEM key The scale is equipped with data library where user can save 1000 details Products base consists of M no record number M0001 1000 needed to recall to it M Id product code inscribed by using keyboard or scanner APW product unit mass used for pieces counting SAMPL inscribing quantity
2. USER MANUAL BD TL Series File 2014 12 08 BD_TL 162 BTL004 GB 2 OPERATION MANUAL BD TL Index k General COSCIDUON seris unra rN AA A tannins 3 2 ZOMIICTC OSS nren n E A E A T 3 De WCCO TOS s ea E A A A E 4 7 Mame 5161 410 AA E A A AA A EA eT A EAA 5 9 General View OF DGIAN CO saranoina A 6 OD Keys and IIOICQIONS aeania a ERE ATAA AEREE ees 8 Preparation of workplace cccccccccesceecsssscesssenssessscestsesscesssentsenssecstsensseseeesesentsenseens 11 Be PEO ala ONO WOK mengei A ease oe 17 9 GCA ETN UNOS annn tecttntasantiesei E E O anaemia 12 10 Operation rules during work with accumulators batteries ccccceseeeetseeseteeeteeeee 13 1 Te ACCU UI ALO exea E nenni T antennae etna 14 Te HOUT OF WOK saeaete toca niccaasaa ane caisanese A 15 TDs PIG OS COUN POS aceasta aed aah ties rei edd te aa ad ais ates 15 14 Summation of measurements series 2X ccceccescessesccssesscetsesssetsessestscessseseeseeeenees 18 15 Permanent tare memory gt PT snnnennennnnennennnnnnnennnnnnnnnnnnnnnnnnrnnnnnnnnnnrnnnnnnnrenrnnnnrnn 19 16 Products data library MEM key uu eccccessccssescctscssccsscssssssccssssssessssessssestsneseteess 20 17 Connecting to computer OF printet sessessesreerserrerrerrerrnrrrerrerrnrrnrrnrrerrnrrnrrnerrerrerae 23 18 Basic FUNCTION GESCHIDLION scorie a 25 19 1 ZOTOING Scale 1G CA OM srr r Taaa E T 25 PAE LEESE E N hose ec PAE AA A T A E A T E A Aa 26 PGS MONU a aE A E A EANA 2 Mai
3. choosing gram as default unit after the scale is turned on Using UNITS key changes actually displayed unit PtArE tArE tArE tArE tArE tArE tArE tArE tArE tArE tArE 10 ph OMAN NA B W WN view edition of constant tare nr 1 view edition of constant tare nr 2 view edition of constant tare nr 3 view edition of constant tare nr 4 view edition of constant tare nr 5 view edition of constant tare nr 6 view edition of constant tare nr 7 view edition of constant tare nr 8 view edition of constant tare nr 9 view edition of constant tare nr 10 After choosing constant tare number a new value can be inscribed using numerical keys and ENTER key confirmation 28 OPERATION MANUAL BD TL totAL ModE totAL register measurement confirmation mode manual MAnUA after pressing gt key automatic Auto after indication stabilization Print totAL work with On printout or without OFF SAVE totAL summing register saved to non volatile memory On or reset after each turning off the scale OFF thr Function allows for comparing weighing result with two programmed thresholds values P1 Lo lower and P2 Hi upper Comparing result is signalized by Lo Ready or Hi marks on display OFF threshold function off on threshold function on run threshold values edition SEt Lo SEt HI SEt Zr Print threshold values printout ModE threshold function work mode net mass MASS or pieces quantity PCS
4. A unitary mass is displayed in middle display section with APW indicator The upper display section displays sample mass 4 Result of calculation is read from lower display Note I It is advised that single piece weight is not less than one reading unit and sample weight used in first phase is bigger than 100 reading units 2 If the unit mass APW is smaller than scale readout unit but bigger than 1 10 of readout unit a APW LOW communicate appears and the counting result blinks If the unit mass is smaller than 1 10 of readout unit APW to LOW communicate appears and pieces counting is disabled 18 OPERATION MANUAL BD TL 14 Summation of measurements series x Scale is equipped with summation register The register enables adding successive results of measurements MAXIS Total 114 8 5 1 Put weighted element on the pan and press 2 button Contents of this register have been showed temporary in middle section display the upper section displays Total sign Note Using a gt key causes subtraction of actual measurement from the register 2 Press several times DATA key for continuous displaying of register value in this case an indicator is turn on Hold 23 or key for more options View viewing summing register value pressing or gt key again will cause displaying average value and measurements quantity Print report printout Reset reset summing register
5. during work with accumulators batteries 1 Scale can be powered from 230V supply through feeder attached with scale Moreover accumulators which are placed in container inside the scale can be used for powering Ordinary batteries can be used as well work with feeder have to be switched off bAttErY function is used for this purpose bAt OFF option which is described in further part of manual Charging batteries can cause their breaking and serious damage of the scale When using batteries in place of accumulators charging during 2 In order to make accumulators batteries discharging time longer automatic switching off display backlight and later the whole scale further is possible during breaks in weighing Configuration of these mechanisms is done using b_ LIGHT and Auto OFF functions 3 Charging accumulators is performed automatically after connecting feeder to the scale also during weighing Accumulator power level can be read using bAttErY function bat LEVEL option 14 OPERATION MANUAL BD TL 11 Accumulator exchange 1 Remove the pan carefully 2 Invert the scale red color 13 3 Remove the cover 2 4 Unscrew tab bolts 6 remove accumulator clamp 5 remove sleeves 3 remove used accumulator 4 5 Sleeves 73 put on new accumulator 4 check the polarization on accumulator indicated by red color put sleeve with red color 6 Arrange accumulator put accumulator clamp 5 and screw bolts 6 7 Pu
6. outPut transoptors out working mode standard impulse IMPULS or signalizator SIGnAL mode SIGNAL mode IMPULS Outputs Outputs P1 t P1 Threshold I P2 P2 Threshold I Threshold II i P3 P3 zero Threshold O treshold If the scale is additionaly equipped with threshold outputs option in IMPULS mode on outputs P1 threshold I and P2 threshold II short circuit impulses appear for about 0 5s On output P3 zero short circuit state appears with the zero threshold indication OPERATION MANUAL BD TL 29 dAtA_b Edlt inscribing number code MODE key switches of the part to edit dELOnE _ inscribing number code MODE key switches parts to delete confirmation YES no dELALL deleting all parts confirmation YES no Products edition enables to define PA Id detail number inscribing APW unitary mass SAMPL default sample quantity PtArE inscribing constant tare to detail thr Lo low threshold value thr Hi upper threshold value thr Zr zero threshold value SAVE saving settings USErS Id 1 view edition user identifier 1 Id 2 view edition user identifier 2 Id 3 view edition user identifier 3 Id 4 view edition user identifier 4 Id 5 view edition user identifier 5 SEtuP AutotA turning on On or off OFF autotare CALIb scale calibration available in not verificated scales Following options will appear CAL on calibration wit
7. successive number choosing this options resets the counter M id product number dAtE date option tIME time option Count counting result APW unitary mass netto net weight tArE actual tare value brutto gross weight totAL results sum nr LCD printout nr and measurement result displayed in one line Sound turning on On or off OFF the sound FILtEr turning on 10 20 30 40 or off OFF additional filters filter reduces the impact of mechanical vibrations on measurement result b_LIGH backlighting settings OFF backlight off On backlight on ECO turning off after 30s without any actions no load change or using keys bAtt as above but only when supplied from accumulators rESOLU turning on LO or off HI scale s decreasing resolution option bAttEr setting accumulator OPERATION MANUAL BD TL 31 OFF charging accumulator turned off On charging accumulator on LEVEL charging status readout in AutoOF scale automatic off function settings OFF scale doesn t turn off ON scale turns off after 5 minutes without actions no load change or using keys bAtt as above but only when supplied from accumulators Flr MW firmware actualization service dEFAUL default settings Maintenance and repairs of small defects 1 The scale should be kept clean 2 Take care that no dirt gets between the platform and the sc
8. with single pieces removing from pan A measurement is performed in two phases first phase single piece weight calculation on the basic of removed pieces default is 10 pieces second phase recalculating pieces in weighting portion WEIGHT gt gt any Turn pieces counting by pressing PCS key 2 Place total then press Enter communicate will appear Put on the pan container with details portion to count and press ENTER WEIGHT 3 Remove 10 then press Enter communicate will appear Remove one or more details from the portion 4 If ten details is removed press ENTER key If amount of removed pieces is other write correct value by using numeric keys and then press ENTER 5 Number of details has been showed on lower section display with PCS indicator A sample mass has been showed in middle section display with APW indication 6 Result of calculation is read from lower section display Turning off pieces counting option is possible by holding PCS or PCS key and releasing it when PCSoFF displays OPERATION MANUAL BD TL 17 Change write a unitary mass using numeric keys During pieces counting indicator PCS user can change actual sample mass Writing a sample mass when counting process is turned off initiates counting process WEIGHT 1 Press SPW key 2 Write sample mass using numeric keys and press ENTER 3 Number of details is displayed on lower display section with PCS indicator
9. ERATION MANUAL BD TL 3 Security rules To avoid electrical shock or damage of the scale or connected peripheral devices it is necessary to follow the security rules below All repairs and necessary regulations can be made by authorised personnel only To avoid fire risk use a feeder of an appropriate type supplied with the scale Pay attention that supply voltage is compatible with specified technical data Do not use the scale when its cover is opened Do not use the scale in explosive conditions Do not use the scale in high humidity If the scale seems not to operate properly unplug it from the mains and do not use until checked by authorised service According to legal regulations it if forbidden to dispose wasted electronic equipment in waste containers Please return wasted scale to the point of purchase or other company specialised in recycling of wasted electronic components OPERATION MANUAL BD TL 5 4 Technical data Load Max 1 5kg 15kg 30kg 0 5 1 2 5 10 Products base Handy products quantity 2 x 15 products All products quantity 1000 products Users bank Users gunatity 5 users Continous working time on accumulators about 48 h with display backlighting 2200mAh about 100h without backlighting Automatic turn Off time when with gt 5 min AutoOFF function accumulators Backlighting automatic turn off when with gt 30 s b_LIGHt function accumulators optional readout units design
10. OPERATION MANUAL BD TL 11 indicator A signalizes that APA option automatic improving of pieces counting accuracy is on in scale s menu indicates if function is on indicator indicates or off without indicator Preparation of workplace Workplace of scale should be chosen carefully This place should be assured a proper temperature and essential area for attendance Weight should stand on stable table Violent movements of air dust vibrations violent changes of temperature or humidity above 90 are inadmissible Scale should be far off from strong electromagnetically or magnetically fields 8 Preparation to work 1 r A E Fo 1 Take the scale pan and feeder out of the package It is recommended to keep the original scale package in order to transport the balance safely in future 2 Place the scale on a stable ground not affected by mechanical vibrations and airflows 3 Put a support pan 2 in wholes 4 Put the overlay pan J 5 Level the scale with the rotating rear legs 6 so that the air bubble in the water level 5 at the front of the scale is in the middle 12 OPERATION MANUAL BD TL If scale has been moved from places with low temperature to places with A N high temperature for example in winter before connecting the scale to supply leave it for about 4 hours in purpose of acclimatization 9 General rules 1 It 1s advised to check scale indication accuracy before and after series of measu
11. Products data edition records Products data can be edited by holding chosen fast choice key or by using MEM key and inscribing record number Longer pressing of MEM key causes record number inscribing screen displaying On upper section display M no sign shows up and on the middle section a field to inscribe record number from 1 to 1000 Inscribe the number using numerical keys and confirm by pressing ENTER Chosen record number will show up on the upper display On the middle one following options will be successively displayed M id product number inscribing using balance keyboard or barcode scanner APW single piece mass SAMPL inscribing quantity of products above which counting results correction algorithm turns on PtArE inserting constant permanent tare value for the detail thr Lo lower threshold value thr Hi upper threshold value thr Zr zero threshold value SAVE saving settings out exit user can also use CLR key WEIGHT 22 OPERATION MANUAL BD TL To speed up options displaying user can press 3 amp or 0 lt button To choose option press ENTER key After choosing the proper option user can insert numerical value using keyboard and confirm it with ENTER key Recalling record Short pressing of MEM key enables to inscribe record number earlier edited and saved which we want to recall We inscribe number using numerical keys and confi
12. Sa scale tare key short press enter user menu hold enter user identification menu when option is active release key to choose the actual user that is displayed Short press permanent tare menu hold predefined tare menu release key to choose the actual tare Short press adding actual netto weight details quantity to TOTAL register hold TOTAL menu access release key to choose the actually displayed option gt u OPERATION MANUAL BD TL Short press substraction of actual netto weight details quantity from TOTAL register hold TOTAL menu acces release key to choose actually displayed option short press pieces counting on putting defined quantity of pieces on pan hold PCS menu access release key to choose actually displayed option Short press pieces counting on taking off pieces from pan hold PCS menu access release key to choose actually displayed option DATA display working mode change in cycles off gross tare unitary mas total thr unit change in cycles g kg Ib changing mode key nr or 1d cancel operation key confirm operation key range switch 1 15 or 16 30 for record library Short press inserting record number or id MODE key switches to recall record from memory hold inserting number or code MODE key switches of the record to save edition unitary mas
13. ale base If found any remove the pan lift it up remove dirt and then replace the pan 3 In case of improper operation caused by short lasting power supply decay unplug the scale from the mains and then plug it again after few seconds 4 It is forbidden to make any repairs by unauthorised persons 5 To repair the scale please contact our nearest service List of authorized services is shown on site www axis pl 6 Damaged scales should be sent to repair in original package only Scale should be protected against pressure Error communicates C 1 6 self test failed if displayed more than 1 minute over 1 min contact an authorised service balance protection rod remove protection rod and cap doesn t work 32 OPERATION MANUAL BD TL the scale was switched on with remove the load from the pan loaded pan unstable ground place the balance on a stable vibrations ground not affected by indicator does air flows mechanical vibrations and airflows balance damage contact an authorized service oe taring 1s progress contact an authorized service not appear OPERATION MANUAL BD TL 33 Declaration of Conformity We AXIS Sp ka z 0 0 80 125 Gdansk ul Kartuska 375B confirm with all responsibility that scales BDI 5TL BD3TL BD6TL BDISTL BD30TL and BD3TLY BD6TLY BDI2TLY BD30TLY marked with CE mark comply the following 1 Directive 2004 108 WE Electromagnetic compatibility and norms harmo
14. computer interface 9 pin SCALE m COMPUTER Connecting cable WD 1 connect scale with printer KAFKA SCALE KAFKA PRINTER Settings og internal switch printer AXIS OPERATION MANUAL BD TL 25 18 Basic function description 18 1 Zeroing scale indication If the scale pan is unloaded and weight indication is other than zero press T lt key WEIGHT WEIGHT 26 OPERATION MANUAL BD TL 18 2 Tare Scale enables to tare zeroing the scale when there is a package on the pan in whole measurement range Total tare and net weight value cannot exceed scale s range Max a WEIGHT measured object WEIGHT OPERATION MANUAL BD TL 27 19 User menu Pressing MENU key enables to use many options special functions and scale configuration Option names show up successively in upper section display To choose displayed option press ENTER key PCS SAMPL APA rS SPL Unit KGrAM Pound GrAM view and edition of default sample quantity inscribing new value using numerical keys and confirmation by ENTER key turning on On or off OFF automatic pieces counting correction function Downloading unitary mass using serial port PORT_1 after earlier inscribing sample quantity successive operation leads to initiation of pieces counting choosing kilogram as default unit after the scale is turned on choosing pound as default unit after the scale is turned on
15. ed not for verification on demand Scale type BD3TLY BD6TLY BD12TLY BD30TLY Load Max 12kg 30kg Readout unit d 5go it e 300x210mm Products base Handy products quantity 2 x 15 products All products quantity 1000 products Users bank Users gunatity 5 users Continous working time on accumulators about 48 h with display backlighting 2200mAh about 100h without backlighting Automatic turn Off time when with accumulators gt 5 min AutoOFF function Backlighting automatic turn off when with gt 30 s b_LIGHt function accumulators 6 OPERATION MANUAL BD TL 5 General view of balance Front view 3 1 Overlay pan 4 keyboard 2 suport pan under overlay p 5 level 3 display 6 rotary legs Back view Ce a Back view option with additional displays OPERATION MANUAL BD TL Interfaces view Feeder RS232C RxD receiver TxD transmitter Attention 5V option supply in RS232C joint is installed only in scales ordered together with a scanner In that case the scanner doesn t need feeder 8 OPERATION MANUAL BD TL 6 Keys and indicators Keys placement ar M16 M17 ENTER MENU gt 06 gt T _ ar Es xT 1 d wil E Fi D ye H f gt I LULES ie Keys description I O turn on off print key complies with port and print settings gt 06 scale zeroing key verificated scale i
16. hout successive steps confirmation CAL StP calibration with successive steps confirmation out exit from calibration Press ENTER key when CAL StP is displayed Inscribe confirm using ENTER standard of mass value that will be used for calibration Wait until scale zero inscribes f CAL StP option is chosen press MENU key when PrESS MENU communicate appears After LOAD communicate appears put standard of mass Gf CAL StP option is chosen press MENU key when PrESS MENU communicate appears 30 OPERATION MANUAL BD TL SErIAL Port 1 and Port 2 serial parameters transmission speed bAud 1200 2400 4800 9600 19200 38400 57600bps quantity of bits in byte DitS 7 8 parity control ParltY none no control Odd non parity Even parity continous transmission Send oF F transmission off StAb transmission after pressing gt key and indication stabilization noStAb transmission after pressing L gt without stabilization Auto after putting on and taking off the product without pressing Ep Cont about 10 results per second ReMOV transmission after taking off the product from the pan Transmision protocol Prot LonG printer computer Eltron label printer activates LADEL option Pen 01 pendrive PEN O1 attachment Port 1 and Port 2 printouts configurations Print HEAdEr header name model and scale nr USEr id user id max 6 digits Prn no printout
17. nized with e PN EN 61000 4 3 A1 2008 A2 2011 e PN EN 61000 6 3 2008 A1 2011 2 Directive 2006 95 WE Low voltage and norms harmonized with e PN EN 61010 1 2004 Moreover scales with the following markings on the name plate C 15 the number of the Notified Body responsible for EC verification 1443 two digit number of the year of EC verification a green metrology sticker with M mark a protective seal affixed by the Notified Body comply with the requirements on the Type Approval Certificate No PL 13 001 and are verified to comply with PN EN 45501 1999 Additional information Conformity evaluation for the Council Directive 2004 108 WE and 2006 95 WE were carried out by Laboratorium Badawcze Oddzia u Instytutu Elektrotechniki in Gda sk accredited by PCA Type Approval Certificate No PL 13 001 was issued by G wny Urz d Miar w Warszawie Notified Body No 1440 Gdansk 14 11 2014 r Per pro Director of AXIS Sp z 0 0 Production Manager Jan Ko czak 34 OPERATION MANUAL BD TL Notes
18. ntenance and repairs Of small defects ccccceccesssestscesssesssessscessseneserseeessenssessesenteens 37 Decl ration Of Conform eeemenenenr cen eee mCermec ener erer ery me mere meee ee meee en meer eee ree 33 OPERATION MANUAL BD TL 3 1 General description BD TL series scales are destined for identical pieces counting and can be used in store houses production control and similar tasks Counting pieces function is based on calculation individual mass of detail from sample weight or inscribed value using keyboard Scale avails a learn algorithm during calculation to correct inaccuracy conversion BD TL is equipped with summing register The register allows addition or subtraction of succesive measurement and observation of the register current State BD TL is equipped with data library products base that enables to save up to 1000 products wherein 30 products can be saved to handy data library that enables choosing product by using only one key Most effective way to work with products labeled by barcode e g EAN13 is to use connection with barcode reader option Readout of barcode recalls product from data library products base Scale conforms European Union safety regulations and is marked with CE sign PKWIU classification 33 20 31 2 Completeness Standard set consist of Scale Support pan Overlay pan Feeder Accumulator piece option User manual Guarantee card SU age ger eee 4 OP
19. of products above which counting results correction algorithm turns on PtArE inscribing constant tare for product not necessary thr Lo lower threshold value not necessary thr Hi upper threshold value not necessary thr Zr zero threshold value not necessary During scale work barcode reader readout of record number causes searching through scale product library and in case of finding the right record recalling to single piece mass and other product data Database can be built in Excel datasheet form where each product has one row and each column have product data This way created database saved in csv extension with semicolons can be send to scale using Scale Database software and scale s serial interface Scale Database is available on our webpage www axis pl en Handy products banks The scale is equipped with two handy detail banks M1 and M2 that are related to fast choice keys M01 M15 and WORRY Each key recalls proper number record Switching between handy detail banks is done by pressing MEM 1 MiaN key indicator on lower section display changes position from M to M2 or vice versa signalizing which bank is used at the moment _ a M2 ou ED MEM2 ast choice keys memory switch indicator on MI position y ry Pp Longer pressing one of the fast choice keys causes displaying chosen parameter edition menu Short key pressing recalls chosen record OPERATION MANUAL BD TL 21
20. rement using any load with known weight To check the scale with legal verification uses a calibration weight with valid calibration certificate In case permissible error is exceeded it is advised to contact the nearest service to calibrate the scale 2 Weighed sample should be placed in the centre of the pan 3 The scale 1s equipped with a tare equal to its range To tare the scale press T lt key Storing a tare value does not extend measuring range but only subtracts it from a load placed on a pan 4 Weighing result should be read when the indicator signalizes stabilization of a result lights which 5 When the scale is not used but it is necessary to be ready to work immediately it can be switched off by pressing I O key The scale reading system is then switched off to standby mode To switch the scale on press I O key The scale is immediately ready to operate maximum accuracy after self tests 6 Before each measurement make sure that zero indicator is displayed If zero indicator does not displayed or communicate appears press 0 lt key and wait until zero indication and zero indicator appears 7 The mechanism of scale is a precision devices and susceptible on congestions impacts and mechanical shakes Do not overload the scale more then 20 of maximum load Max Do not press a pan by hand M Scale should be protected during the transport OPERATION MANUAL BD TL 13 10 Operation rules
21. rm using ENTER key Choosing empty record is signalized by EMPtY communicate on middle section screen and a sound signal To cancel press CLR key OPERATION MANUAL BD TL 23 17 Connecting to computer or printer The scale is equipped with RS232C which can be used to connect external devices such as a computer or a printer When cooperating with a computer data is send after initiate signal from a computer or after a press E button When cooperating with the scale a computer should be equipped with a program which enables processing data from the scale The Axis company offers programs to cooperating with scales These programs are available on site www axis pl Test RS232C program to tests serial connections full version ProCell program enabling cooperation with Microsoft Excel or different Windows applications demo version Information for programmers transmission protocol describe Signal description Computer gt Scale initialising signal S I CR LF 53h 49h ODh OAR Scale gt Computer weighing result according to the diagram below 16Bytes transmission parameters Sbits 1stop no parity 4800bps Byte description Byte 1 S QN Or Space 2 space 324 digit or space 5 9 digit decimal dot or space 10 digit H Space 12 k l c p or space 13 2 b t c or 14 Space I5 CR 16 LF 24 OPERATION MANUAL BD TL Connecting cable WK 1 connect scale with
22. s inserting numerical values keyboard Short press fast recalling record 1 30 from memory handy products hold save edition menu of product as 1 30 record 10 OPERATION MANUAL BD TL Scale indications WEIGHT Scale display is divided into three sections WEIGHT upper DATA middle and COUNT lower Each of these sections has its own measurement indication and information indicators that complement main information or describe scale state Indicator 1s active when there is a lt 4 mark next to it On above screen Oand M indicator is active In scales with additional displays on the back each display corresponds to proper section WEIGHT DATA 1 COUNT Indicators section WEIGHT indicator measurement result stabilization indicator O lt zeroing indicator unloaded scale indicator NET netto weight after using gt T lt key indicator O signalizes active Autotare option AutotA in scale s menu indicates if function is on indicator indicates or off without indicator Indicators section DATA indicator B G signalizes displaying gross weight indicator T signalizes displaying actual tare indicator APW signalizes displaying average unitary weight indicator signalizes displaying summing register Indicators section COUNT indicator M1 records baze range 1 15 active indicator M2 records baze range 16 30 active indicator PCS pieces counting
23. t on cover 2 8 Invert the scale 9 Put on pan carefully OPERATION MANUAL BD TL 15 12 Start of work Leave the pan empty plug the feeder to the mains 230V S50Hz and plug the feeder connector to the 12V power socket at the bottom side of the scale Scale will execute following step display type of scale and version of program zeroing the indication After displaying an indication on the upper display section scale is ready to work 13 Pieces counting PCS Scale enables to count identical pieces e g turnbuckles or buttons Measurement with unitary weight calculated from given sample A measurement is performed in two phases first phase single piece weight calculation on the basis of defined pieces amount default is 10 pieces second phase pieces counting 1 Put on pan quantified details sample 2 Turn on pieces counting by pressing gt PCS key MAXIS Place 10 then 3 Place 10 then press Enter communicate will appear If the quantified sample consists 10 pieces press ENTER If amount of detail is other write correct value by using numeric keys and press ENTER 4 Number of details is diplayed on lower section of display with PCS indicator A single piece mass is displayed in middle section with APW indicator 5 Remove sample form pan and put a portion of pieces to count 6 Result of calculation is read from lower section display 16 OPERATION MANUAL BD TL Measurement

Download Pdf Manuals

image

Related Search

Related Contents

User's Manual  DJ-PX2 取扱説明書ダウンロード  USER MANUAL KARAOKE STEREO AMPLIFIERS 103.124  T1X-03 (AC) TREADMILL SERVICE MANUAL  VHDL Primer - Signals and Systems  Télécharger - Plateforme Elsa  1428_p01_FT_HC_ Plus_0.5_SR_ES_14-15  radiograbadora con reproductor de dvd y puerto usb  Satellite L650/L655/L650D/L655D / Satellite Pro série L650  Black & Decker 5027 Instruction Manual  

Copyright © All rights reserved.
Failed to retrieve file