Contents

1. Bearing Type Chuck Type Rotor Air pressure at handpiece connection Water Supply Pressure at handpiece connection 52 TWINPOWER TURBINE 4H with light PAR 4HEX 0 45 PAR 4HEX O KV 45 Ball Bearing Push chuck Autoclavable Capsule Cartridge Recommended 0 23 0 25 MPa Usable Range 0 2 0 29 MPa Recommended 0 1 0 2 MPa Usable Range 0 05 0 2 MPa Operation 2011 01 31 Exhaust air pressure at handpiece connection Speed Air flow Volume Weight Head Height Head Diameter Length Operation 2011 01 31 0 03 MPa max 370 000 30 000 rpm at 0 2 MPa 30 5 NL min at 0 2 MPa 53 g PAR 4HEX O 45 59 g PAR 4HEX O KV 45 13 2 mm 10 5 mm 107 mm PAR 4HEX O 45 115 mm PAR 4HEX O KV 45 Technical Description 53 Technical Description air pressure exceeds 0 03 MPa 54 Operation 2011 01 31 Technical Description Usable Burr and Point Shank Diameter ISO standard 1 59 1 60 mm Tip Diameter 2 0mm max Total Length 20 25 mm max The stream of water reaches the tips of burrs 20 to 25 mm long Shank Length 10 mm min Shank Length aa e at En rooves 4 J T Tip Diam Et Shank Diam sail REESE D pF ISO Standard Total Length DO NOT USE Operation 2011 01 31 55 Technical Description 56 Operation 2011 01 31 Technical Description ANOTE e Always use burrs and points with clean shanks dirty shanks cause the chuck
2. Storage Storage Conditions Temperature 10 C 14 F 70 C 158 F Reletive Humidity 10 85 RH without condensation Atmospheric pressure 700 1 060 hPa Do not expose to direct sunlight frequently or for long times Store the handpiece in a clean dry place after autoclaving it Operation 2011 01 31 41 Maintenance and Inspection Maintenance and Inspection Regular Inspection Maintenance and inspection are generally consider to be the duty and obligation of the user but if for some reason the user is unable to carry out these duties he may rely on a qualified medical device serviceman Contact your local dealer or the J Morita Corp for details Replace the parts listed in the Parts Lists as necessary depending on degree of wear and length of use This instrument should be inspected every 3 months in accordance with the following maintenance and inspection items 42 Operation 2011 01 31 Maintenance and Inspection Inspection Items m Chuck Gripping Strength Use the Chuck Tester to check the chuck s gripping strength Replace the capsule cartridge if the chuck has lost its gripping strength m Cap Tightness Make sure that the cap and the cap screw are tightened properly Rotation and Water Make sure the handpiece operates smoothly and emits a stream of water For repairs contact your local dealer or the J Morita Corp Parts List m Capsule Cartridge PAR4HEX 45 Regularly Re
3. S A TEL 1 949 581 9600 FAX 1 949 465 1095 http Awww jmoritausa com J MORITA EUROPE GMBH Justus Von Liebig Strasse 27A D 63128 Dietzenbach Germany TEL 49 6074 836 0 FAX 49 6074 836 299 http Awww jmoritaeurope de SIAMDENT CO LTD 444 Olympia Thai Tower 3rd Floor Ratchadapisek Road Samsennok Huay Kwang Bangkok 10310 Thailand TEL 66 2 512 6049 FAX 66 2 512 6099 http www siamdent com J MORITA CORPORATION Australia and New Zealand Suite 2 05 Aero 247 Coward Street Mascot NSW 2020 Australia TEL 61 2 9667 3555 FAX 61 2 9667 3577 http oceania morita com PUB H5069 E Printed in Japan
4. gt CP4 LD lt with LED light gt CP4 W LD lt with LED light and spray control gt Coupling Before use check the following items Water oo Spray Air Does the connection end of the tube match the coupling Fe ae Lamp voltage is correct LO wo Exhaust This coupling cannot be connected to a tube that does not Drive Air E have light capability e Electrical Contacts ANOTE e The CP4 light will burn out more quickly if voltage is greater than the value specified if it uses a long fade out time or if the chair applies and cuts off the voltage suddenly 60 Operation 2011 01 31 CP4 O WO CP4 LD WD CP5 O Coupling CP4 O lt with halogen lamp light gt CP4 LD lt with LED light gt CP4 WO lt with halogen lamp light and Spray Control gt CP4 W LD lt with LED light and Spray Control gt ISO 9168 Type 3 C Coupling ISO 9168 Type 3 C Coupling Weight Input Voltage AC DC 3 3 V 0 05 V Recommended AC 2 5 10 VI DC 25 15 V for coupling contacts Lamp power supply must conform to IEC60601 1 and voltage is SELV special safe low voltage Input power supply must conform to IEC60601 1 Reinforced insulation Double insulation Operation 2011 01 31 61 Technical Description CP5 0 lt with Fiber Optic gt Coupling Before use check the following items Does the connection end of the tube match the coupling Water Spray Air This coupling cannot be connected to a tube that does not have light capability This coupli
5. handpiece but have it repaired instead 8 Operation 2011 01 31 Usage lt Handpiece Attachment gt For Morita CP4 O CP4 WO CP4 LD CP4 W LD and CP5 O couplings PAR 4HEX 0 45 Refer to the user s manual for PAR 4HEX O KV KaVo MULTIflex and MULTIflex LUX couplings lt Connect gt lt Disconnect gt Hold the tube and slide the handpiece on until it clicks securely into place Pull the coupling slightly towards the tube and then pull the handpiece off Operation 2011 01 31 9 For information on assembling the CP4 O WO CP4 LD W LD and CP5 O Coupling refer to the page 60 10 Operation 2011 01 31 Usage Inserting and Removing Burrs lt Insert gt lt Removal gt Me Push Button e a Carefully insert the burr as Hold down the push button firmly and push the Hold the push button down and far as it will go burr all the way in then release the push button pull the burr straight out Operation 2011 01 31 11 Yes No 12 Operation 2011 01 31 Operation 2011 01 31 Usage 13 Usage ANOTE e Crown removal and other similar operations produce considerable vibration and can cause the bur to get stuck in the handpiece Avoid this by frequently removing and reinserting the bur e In case of abnormal noise or vibration during use replace the bur If this eliminates the problem the bur was defective If this does not solve the problem the handpiece needs to be repaired e After long usage wear o
6. other than the intended purpose as specified in this manual 2 Operation 2011 01 31 Prevent Accidents Disclaimer m The J Morita Mfg Corp will not be responsible for accidents equipment damage or bodily injury resulting from 1 repairs made by personnel not authorized by the J Morita Mfg Corp 2 any changes modifications or alterations of its products 3 the use of products or equipment made by other manufacturers except for those procured by the J Morita Mfg Corp 4 maintenance or repairs using parts or components other than those specified by the J Morita Mfg Corp and other than in their original condition 5 operating the equipment in ways other than the operating procedures described in this manual or resulting from the safety precautions and warnings in this manual not being observed 6 workplace conditions and environment or installation conditions which do not conform to those stated in this manual such as improper electrical power supply 7 fires earthquakes floods lightning natural disasters or acts of God Operation 2011 01 31 3 Prevent Accidents m The J Morita Mfg Corp will supply replacement parts and be able to repair the product for a period of 10 years after the manufacture of the product has been discontinued m Warranty is honored only when a claim is accompanied by the warranty agreement with purchase date product name and model serial number inscribed on the body of the product and name
7. to wear out more quickly and lose its gripping power e Always carefully remove all cleaning fluids before inserting a burr into the chuck some cleaning fluids are corrosive and if a burr or point with cleaning fluid on it is inserted the chuck could be ruined e Ifa dirty burr or one with cleaning fluid on it has been inserted by mistake contact your local dealer or the J Morita Office to have the instrument inspected e Carefully read the instruction manual of the burr maker e Use only burrs made of a single piece of metal do not use burrs whose head is welded to the shank e Welded joints break easily Operation 2011 01 31 57 Technical Description Terminology and Symbols CE 0197 marking Conforms to European medical Ball Bearing Type ae Manufacturer eis Name device Directive 93 42 EEC 1 MORITA MFG CORP Ma Ball FH D Model Requires AR Lubrication Handpieces with this symbol may Serial Number E be cleaned and disinfected with a The first character of the serial number Autoclavable up to 135 C thermal washer disinfector specifies the year of manufacture as follows Y 2010 Z 2011 58 Operation 2011 01 31 Operation Instructions ual Manufacturer lec aer Authorized representative in the European Community Operation 2011 01 31 Technical Description 59 Technical Description CP4 O WO CP4 LD W LD CP5 O Coupling CP4 0 lt with light gt CP4 WO lt with light and spray control
8. High Speed Air Turbine Handpiece TWINPOWER TURBINE 4H cs M PAR 4HEX O 45 lt with light gt PAR 4HEX O KV 45 lt with light gt Operation Instructions Manufactured by J MORITA MFG CORP This manual covers the TWINPOWER TURBINE 4H series handpieces which can be connected to Morita couplings CP4 O CP4 WO CP4 LD CP4 W LD or CP5 O and other manufacturer s couplings PAR 4HEX O 45 PAR 4HEX O KV 45 1 Morita CP4 O CP4 WO CP4 LD CP4 W LD and CP5 O coupling 2 KaVo MULTIflex and MULTIflex LUX coupling KaVo MULTIflex and MULTIflex LUX are registered trademarks for Kaltenbach amp Voigt GmbH Notice Of Protect Intellectual Property CN PAT 03123631 6 DE PAT 10060152 5902108 3897953 CN PAT 03123632 4 DE PAT 10320902 3208345 4088475 DE PAT 19807566 US PAT 6676374 3672781 4122174 DE PAT 19860953 US PAT 7048540 3795722 4160319 CONTENTS Prevent Accidents sisi bad 1 Maintenance and Inspection oocccocncccncccnicncnnonnnnno 42 Parts Identification and Accessories oococccoocccccnoccncnno 5 Troublesho0 lidia 45 US aliens ooo ic 8 Technical Description AEN 52 Inspecting and Sterilizing Before Use 8 CP4 O WO CP4 LD WD CP5 O Coupling 60 Inserting and Removing Bure 11 After Ee EE 15 a as o cee 16 Replacement Parts and Storage ccccooccnccccccncnoncnnos 29 Capsule Cartridge Hepnlacement 32 Cartridge Lamp or LED Replacement 40 Storage c
9. ain So eee ar eee 41 Operation 2011 01 31 Prevent Accidents Prevent Accidents Introduction Thank you for purchasing a TWINPOWER TURBINE 4H handpiece This instrument is designed for dental treatment such as grinding drilling and polishing teeth For optimum safety and performance read this manual thoroughly before using the unit and pay close attention to the warnings and notes Keep this manual at hand for ready reference Safety Precautions The instrument must be used in accordance with the instructions in this manual Read this manual thoroughly prior to operating or maintaining the instrument Operation 2011 01 31 1 Prevent Accidents The following symbols and expressions indicate the degree of danger and harm that could result from ignoring the instructions they accompany A WARNING This warns the user of the possibility of extremely serious injury or complete destruction of the instrument as well as other property damage including the possibility of fire ANOTE This warns the user of the possibility of mild injury or damage to the instrument O Usage Note This alerts the user of important points concerning operation or the risk of equipment damage The user i e clinic hospital etc is responsible for the management maintenance and use of medical devices This instrument must not be used by anyone except legally qualified dentists and oral surgeons practitioners This instrument must not be used for any
10. er No 5811832 O Lamp Cover O ring No 5811833 Operation 2011 01 31 Replacement Parts and Storage For Morita CP4 LD W LD Coupling LED No 5011575 yr 8 O O ring No 5811833 LED Cover No 5011025 31 Replacement Parts and Storage Capsule Cartridge Replacement Replace the capsule cartridge if worn ball bearings result in poor or irregular rotation if burrs are difficult to insert or remove or if the chuck loses it gripping power The capsule cartridge and its O ring wears out and must be replaced periodically The bearings and other parts wear out and make more noise after a certain period of time A WARNING e If used in this condition a burr or point could come out inside the oral cavity and injure the patient or be swallowed ANOTE e Do not fail to use the capsule cartridge for the PAR 4HEX 32 Operation 2011 01 31 lt Remove old capsule cartridge gt goers Screw g Ca D p oo O ring Check for the PAR 4HEX 45 marking S Capsule Cartridge i Take the cap screw out with the screwdriver Operation 2011 01 31 Replacement Parts and Storage Cap Tool For PAR 4HEX O Fit the cap tool securely onto the cap guide and take the cap 33 Replacement Parts and Storage Push Out Push the old cartridge out by pressing the aero skirt around the chuck opening firmly down on a hard flat surface NN 34 Screw the nozzle assembly onto
11. n bearings results in greater noise 14 Operation 2011 01 31 Usage After Use Disconnect the handpiece from the tube and remove the point or burr Burrs and points may get stuck in the handpiece if they are left in for too long Always remove the burr or point after finishing treatment Operation 2011 01 31 15 Sterilization Sterilization lt Cleaning gt Clean debris off the attachment with a brush and running water Clean the water holes with the wire provided if they get plugged up with cutting debris or impurities in the water After cleaning dry it off with air from the threeway syringe or some other method and then wipe it with a piece of gauze dampened with Ethanol for Disinfection Ethanol 70 80 vol Water Hole Wire Syringe Nozzle 16 Operation 2011 01 31 Sterilization lt Disinfection gt Use a piece of clean gauze and brush to disinfect the whole surface of handpiece with Ethanol for Disinfection Ethanol 70 80 vol Operation 2011 01 31 17 Sterilization Thermal washer disinfector Handpieces with this symbol may be cleaned and disinfected with a thermal washer disinfector To use a thermal washer disinfector first read the operation instructions for the unit Strictly follow the instructions attached for cleaning mode and solution Improper cleaning modes and solutions will damage the instrument 1 Follow the disinfector manufacturer s recommendations for cleaning solutions a
12. nd methods for dental instruments Do not use strong acidic or alkaline solutions Thoroughly rinse off all cleaning solution 18 Operation 2011 01 31 Sterilization lt Lubrication gt Before autoclaving do not fail to lubricate and clean with AR spray l Look here coupling mark There are different spray nozzles for each type of coupling Look at the side of the nozzle to check this Make sure you use the right one No Mark Morita couplings CP4 O WO CP4 LD W LD and CP5 O PAR 4HEX O KV KaVo coupling PAR 4HEX O KV Operation 2011 01 31 19 Sterilization A WARNING e Do not point the spray nozzle at anyone and do not use the spray near an open flame A NOTE e The handpiece will malfunction without regular AR spray maintenance e Never use any type of spray other than AR spray Other lubricants will cause the coupling O ring to swell and make it difficult to connect and disconnect Also it could make it take longer to stop in an emergency 20 Operation 2011 01 31 Operation 2011 01 31 Sterilization Shake AR spray can 2 or 3 times before using it Raise the lever on the nozzle assembly and swivel the chuck nozzle down into position Cover the head with gauze insert the nozzle and spray for 2 or 3 seconds Push the nozzle lever down Insert the nozzle into the handpiece connection end and spray for 2 or 3 seconds 21 Sterilization 22 Operation 2011 01 31 Sterilization lt Co
13. ng cannot be connected to a 4 hole tube Exhaust Drive Air eee CP5 O lt with Fiber Optic gt ISO 9168 Type 2 B Coupling Lamp power supply must conform to IEC60601 1 and voltage is SELV special safe low voltage Fiber Optic 62 Operation 2011 01 31 CP4 O WO CP4 LD WD CP5 O Coupling Connect Coupling Before first using the coupling or if the handpiece coupling connection gets stiff take the nozzle off the AR spray can and lightly spray the coupling s o rings Line up the projections on the coupling with the indentations Tighten securely with the wrench provided in the tube and then tighten up the cover nut Operation 2011 01 31 63 Technical Description A NOTE e Before connection make sure the tube connector is clean and free of debris e The light will lose its brightness if the end of the fiber optic cable is scratched or otherwise damaged by being dropped for instance e Air or water may leak if the coupling is not tightened up enough 64 Operation 2011 01 31 CP4 O WO CP4 LD W LD CP5 O Coupling Cleaning Wipe the outside cover with Ethanol for Disinfection Ethanol 70 80 vol A NOTE e Coupling must NOT be autoclaved or cleaned ultrasonically e The coupling could be damaged if it is soaked in Ethanol for Disinfection Ethanol 70 80 vol or cleaned with a strong corrosive solution e Clean both ends of the light guide if the light seems to have lost its brightness Operati
14. nger out a little and then release it If the plunger moves back in the valve is OK Water Pipe 4 Replace the valve if the plunger does not go back in at all Operation 2011 01 31 69 Technical Description Replacement One way Valve 1 Use a needle or similar object to remove the gasket 2 Remove the old valve and replace it with a new one 3 Replace the gasket in its original position Gasket ANOTE e Do not damage the part of the gasket that bunches up against the water pipe as it is required to make an effective seal 70 Operation 2011 01 31 EU Authorized Representative under the European Directive 93 42 EEC MEDICAL TECHNOLOGY PROMEDT CONSULTING GMBH Altenhofstraf e 80 66386 St Ingbert Germany TEL 49 6894 581020 FAX 49 6894 581021 The authority granted to the authorized representative MEDICAL TECHNOLOGY PROMEDT Consulting GmbH by J Morita Mfg Corp is solely limited to the work of the authorized representative with the requirements of the European Directive 93 42 EEC for product registration and incident report we J MORITA MFG CORP 680 Higashihama Minami cho Fushimi ku Kyoto 612 8533 Japan http www jmorita mfg com Distributors J MORITA CORPORATION Tokyo Office 11 15 2 Chome Ueno Taito ku Tokyo 110 8513 Japan Osaka Office 33 18 3 Chome Tarumi cho Suita Osaka 564 8650 Japan http asia morita com http oceania morita com J MORITA USA Inc 9 Mason Irvine CA 92618 U
15. nnect gt lt Operate gt lt Disconnect gt Connect the handpiece to its tube Operate the handpiece for about Disconnect the handpiece 15 seconds to blow out excess lubricant Operation 2011 01 31 23 Sterilization lt Check Chuck s Gripping Power gt Carefully insert the chuck tester as Firmly hold down the push button Carefully pull on the tester until the far as it will go and push the tester all the way blue line appears in then release the button 24 Operation 2011 01 31 If the blue line appears the chuck is OK e Blue Line Stop pulling if the blue line appears and let the tester slowly go back to its original position Hold the push button down firmly and take the tester out of the chuck Operation 2011 01 31 Sterilization If the Blue Line Does NOT Appear Chuck has lost gripping power J oj Clean the chuck with AR spray and test it again If the chuck still fails the test replace the capsule cartridge 25 Sterilization 26 Operation 2011 01 31 Sterilization lt Packaging and Sterilization gt Wipe the handpiece with a piece of gauze dampened with Ethanol for Disinfection Ethanol 70 80 vol and put it in a Sterilization pouch Recommended Autoclaving Conditions In a sterilization pouch at least 5 minutes at 134 C 273 2 F Minimum drying time after sterilization 10 minutes 1 Do not sterilize in any way except autoclave Do not fail to clean and lubricate the in
16. nt Parts and Storage Align notch and hole Do not tighten the cap too much Tighten up the cap screw with the This could damage the threads so screwdriver that the hole and notch no longer line up 37 Replacement Parts and Storage 38 Operation 2011 01 31 Replacement Parts and Storage Insert the nozzle into the handpiece Connect the handpiece and operate it for at least 15 seconds to blow connection end and spray for 2 or 3 the excess lubricant out of the head Then wipe the handpiece with a seconds piece of gauze Always use AR spray after replacing the cartridge Order capsule cartridges from your local dealer or the J Morita Office When ordering always specify the model PAR 4HEX 45 Operation 2011 01 31 39 Replacement Parts and Storage Cartridge Lamp or LED Replacement For KaVo PAR 4HEX O KV lamp replacement refer to the user s manual for the couplings of its maker A WARNING e Turn off the power switch to avoid the risk of burns and electrical shock e The lamp and its cover are quite hot immediately after the lamp has burned out Avoid burning yourself do not touch these parts ANOTE e Do not leave fingerprints or any foreign substances on the new lamp These could cause the lamp to break as soon as it is turned on which could cause an injury If necessary use Ethanol for Disinfection Ethanol 70 80 vol to clean the lamp 40 Operation 2011 01 31 Replacement Parts and Storage
17. of the distributor 4 Operation 2011 01 31 Parts Identification and Accessories Parts Identification and Accessories Parts Identification Light Guide l l Push Button Head Body Handpiece Connection Connection end differs for models Tool Guide Aeroskirt Notch Water Hole Water comes out in a stream not a misty spray Operation 2011 01 31 5 Parts Identification and Accessories Accessories Chuck Grip Tester Water Hole Wire No 5010695 No 5250940 H Up Ethanol disinfectable Autoclavable Screwdriver No 5011440 Ethanol disinfectable Cap Tool No 5011328 also used to change lamp and LED Ethanol disinfectable Operation 2011 01 31 AR Spray 4H Spray Nozzle No 5010212 or No 5010216 No 5010307 PAR 4HEX 0 Ethanol disinfectable Ethanol disinfectable Operation 2011 01 31 Parts Identification and Accessories 4H Spray Nozzle No 5010293 PAR 4HEX O KV k Ethanol disinfectable Usage Usage Operating Conditions Temperature 10 C 50 F 40 C 104 F Relative Humidity 30 75 Atmospheric pressure 700 1 060 hPa Inspecting and Sterilizing Before Use The handpiece is not sterilized before shipping It must be autoclaved before being used for the first time Make sure that the cap and cap screw are tightened properly and that there is no gap between the head and the cap If you discover any problem with the above items do not use the
18. on 2011 01 31 65 Technical Description Spray Adjustment CP4 WO CP4 W LD Indicator Turning the dial in the direction indicated by the arrow in the illustration will gradually reduce the amount of spray and then reach 0 For maximum spray turn the dial until the W matches up with the indicator See illustration Spray Control Dial Su Tube Ring 66 Operation 2011 01 31 CP4 O WO CP4 LD W LD CP5 O Coupling ANOTE If the coupling is not securely tightened up with the wrench water or air could leak Operation 2011 01 31 67 Technical Description Replacement lt Coupling O ring Replacement gt O rings Replace the o rings if air or water starts leaking from the connection After replacement take the nozzle off the AR spray can and lightly apply a little oil on the new o rings A WARNING e Do not fail to replace all the o rings otherwise air pressure cold cause the tube to suddenly disconnect and this could injure the patient 68 Operation 2011 01 31 CP4 O WO CP4 LD WD CP5 O Coupling lt One way Water Valve Replacement gt Inspecting One way Valve Cutting debris and other foreign matter could be sucked into the water tube if the one way valve is not working properly Inspect it once a month 1 Remove the needle from a plastic syringe and fit the end over the SE water pipe E gt 2 Check that there are no gaps between it and the gasket W i 3 Pull the plu
19. quired Replacement Parts m Cap Operation 2011 01 31 43 Maintenance and Inspection Disposal of Medical Devices Any medical devices which could possibly be contaminated must be first decontaminated by the responsible doctor or medical institution and then be disposed of by an agent licensed and qualified to handle medical and industrial waste Service and Other Contacts For repair or other types of service contact your local dealer or the J Morita Office 44 Operation 2011 01 31 Troubleshooting Troubleshooting If the instrument does not seem to be working properly the user should first try to inspect and adjust it himself If the user is unable to inspect the instrument himself or if the instrument fails to work properly after being adjusted or after parts are replaced contact your local dealer or the J Morita Corp Operation 2011 01 31 45 Troubleshooting Poor Rotation Lubricate with AR spray And then disconnect handpiece and step on foot pedal Does air come out of the end of the tube with enough force No Defective tube Contact serviceman Yes If other handpieces work OK replace the capsule cartridge Make sure the capsule is the correct one 46 Operation 2011 01 31 Troubleshooting Poor Water Delivery Disconnect handpiece Check coupling connection Step on foot pedal Does air comes out of the end of the tube with enough force No Defective tube or water lines inside chair Yes Replace the co
20. strument before autoclaving it Autoclaving and drying temperatures must not exceed 135 C 275 F After autoclaving take the instrument out of the autoclave as soon as it cools off A WARNING e To prevent the spread of serious life threatening infections such as HIV and hepatitis B the handpiece must be autoclaved after the completion of each patient Operation 2011 01 31 27 Sterilization A NOTE e Remove the bur or point before autoclaving e Do not touch the push button when operating the handpiece to remove excess spray This could damage the cap or the capsule cartridge e Instruments are extremely hot after autoclaving do not touch them until they cool off 28 Operation 2011 01 31 Replacement Parts and Storage Replacement Parts Replace the parts as necessary depending on degree of wear and length of use Order parts from your local dealer or the J Morita Corp Capsule Cartridge with O ring and screw Cap with O ring and screw No 5011010 No 5011387 Operation 2011 01 31 Replacement Parts and Storage 29 Replacement Parts and Storage For Morita CP4 O WO CP4 LD W LD and CP5 O Coupling O Water Val Coupling Wrench for 4H and 5H ne way Water Valve No 5811837 Coupling Gasket No 5011831 CP4 No 5811838 CP5 No 7911823 30 O ring Set for 4H and 5H No 5811835 SE Operation 2011 01 31 For Morita CP4 O WO Coupling Cartridge Lamp No 5011570 Le er 4H Lamp Cov
21. the spray can with the nozzle for the handpiece connection sticking straight out Insert the nozzle into the handpiece connection end and spray for 2 or 3 seconds Connect the handpiece to its tube Operate the handpiece for 2 or 3 seconds to blow out excess lubricant and clean the head Clean the cap with AR spray Operation 2011 01 31 lt Insert new cartridge gt Spray a little AR spray inside the head Operation 2011 01 31 Line up projection and groove Make sure all 3 O rings are on the cartridge Line up the projection on the cartridge with the groove in the head and push it all the way in Replacement Parts and Storage Screw the cap on a little but leave a gap large enough for a new O ring Use tweezers to put the O ring provided with cartridge between the cap and head 35 Replacement Parts and Storage Replace the cap if the projection on the inside is Screw the cap down manually until it is seated on the head worn away Do not use the cap tool to screw down the cap from the beginning this could damage the threads A WARNING e The O ring for the cap must be replaced with the new one provided Otherwise the cap could come off inside the patient s mouth and be swallowed or cause an injury 36 Operation 2011 01 31 Fit the cap tool securely onto the cap and tighten up the cap Line up the notch on the cap with the hole for the cap screw Operation 2011 01 31 Replaceme
22. upling s o ring Or clean water hole refer to next page for cleaning l Make sure the O rings on the capsule cartridge are properly installed If this does not solve the problem contact your local dealer or the J Morita Corp Operation 2011 01 31 47 Troubleshooting How to clean water hole Water Hole Wire Use the wire provided to clean out the water hole 48 Syringe Nozzle After cleaning blow the hole out with a syringe and wipe the handpiece with gauze dampened with Ethanol for Disinfection Ethanol 70 80 vol Operation 2011 01 31 Cannot insert burrs or points Check that burrs and points are OK No Use only burrs and points that are suitable and in good shape Yes Lubricate with AR spray refer to next page for lubrication l If this does not solve the problem replace the capsule cartridge and cap And make sure the cartridge is the correct one Operation 2011 01 31 Troubleshooting 49 Troubleshooting Cover the head with a piece of gauze insert the Connect the handpiece and run it for 15 seconds to blow nozzle into the chuck and spray for 2 or 3 seconds out excess spray Then wipe it clean with a piece of gauze 50 Operation 2011 01 31 Light doesn t work Lamp or LED may be burned out No Check tube and chair Yes Replace lamp or LED Operation 2011 01 31 Troubleshooting 51 Technical Description Technical Description Name Model Handpiece