Home

User Manual English - CMS

image

Contents

1. Series LOUDSPEAKER MANAGEMENT User Manual Introduction Read these instructions Keep these instructions Heed all warnings Follow all instructions Do not use this apparatus near water Clean only with dry cloth Do not block any ventilation openings Install in accordance with the manufacture s instructions Do not install near any heat sources such as radiators heat registers stoves or other apparatus including amplifiers that produce heat Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the other grounding type plug has two blades and a third grounding prong The wide blade or the third prong are provided for your safety If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet 10 Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus Use only attachments accessories specified by the manufacturer 12 Use only with the cart stand tripod bracket or table specified by the manufacturer or sold with the apparatus 13 14 15 16 When is used use caution when moving the cart apparatus combination to avoid injury from tip over Unplug this apparatus during lighting storms or when unused for long periods of time Refer all s
2. OUTPUT 6 OUTPUT 1 OUTPUT 2 OUTPUT 3 OUTPUT 4 OUTPUT 5 OUTPUT 6 OUTPUT 1 OUTPUT 2 OUTPUT 3 OUTPUT 4 OUTPUT 5 OUTPUT 6 2x3 5 1 INPUT B Way 0 260 11 Way 0 260 11 OUTPUT 6 2 2 Way 0 240 11 4 Way DP240 II 3 1 Way 0 240 11 INPUT OUTPUT B 4 2 Mono Sub DP240 II Appendix Different Device Comparision Model DP260 1I DP240 II Channel 2 gt U 2 Filter 10 Channel 6 4 He D m Filter 7 2 Delay 10 5
3. OO INPUTS 000000 0000 1 2 LCD Sreeen Show the of last recalled memory on the bottom line of the screen and current device model name on the top line Also used to show all parameters as they are edited and all menu selections BACK NEXT Moves backwards or forward through list of parameters MENU Activates the main menu BYPASS Bypass filter QUIT Quit key ENTER Enter key Rotary Encoders Three velocity encoders adjust parameters MUTE These buttons illuminate when pressed and mute audio for that channel Press and Hold 3 seconds Access current channel parameters Meters Input and Output meters show dB from clipping point Red CLIP LED show signal overflow Yellow LED show signal near 3dB Rear Panel INPUTS 220 50Hz gt CAUTION A A 1 2 Power Switch turns the device s mains supply off and on 2 RS232 RS232 standard via a 9 pin D type connector for connection to PC 3 Audio Inputs 3 pin XLR sockets are provided for each channel All are fully balanced pin 2 hot 3 cold screen 4 Audio Outputs 3 pin XLR sockets are provided for each channel All are fully balanced pin 2 hot 3 cold screen Diagram of input channels Bo gg Diagram of output channels HPF LPF PEQ DELAY GAIN LIMITER MUTE Input Gai
4. Outputs 4 6 electronically balanced Source Imp lt 60ohms Min Load 600 Max Level 15dBm Digital Audio Sample Rate 96kHz Frequency Response 0 5dB 20Hz 20kHz Distortion lt 0 02 QIkHz 15 ADC Dynamic Range gt 0dB 20Hz 20kHz A Weight DAC Dynamic Range gt 11048 20Hz 20kHz A Weight Propagation Delay 0 2 5 DP240 II DP260 II Delay 0mS Output Min Step Size 0 010 5 4 Input Gain 40dB to 6dB 0 I dB steps Output Gain 40dB to 1588 in 0 1dB steps Multi Type Filters 10 per Input 7 per Output Freq Range 20Hz 20kHz 1 36 Octave steps Filter Q BW 0 4 to 128 Filter Type parametric equaliser HiShelf LoShelf High and Lowpass Filters Freq Range 20Hz 20kHz 1 36 Octave steps Slope 6 12 18 24 36 48 dB Octave Type Butterworth Linkwitz Riley Bessel Limiters Threshold 10 15dB IdB steps Attack time 0 3 90mS Release time 0 1 2 0 second Display 2x20 Character LCD Connectors Inputs 3 pin female XLR Output 3 pin male XLR RS232 9 pin DEE connector Power 3 pin IEC Power Voltage 220V 50 60Hz Power Consumption lt 15 watts Weight 2 7kg Net 4 0kg Shipping Size 1 75 10 x 19 x 7 7 44 x 482 x 197 mm Appendix Crossover Configurations 2x2 Way 0 260 11 OUTPUT 1 OUTPUT 2 OUTPUT 3 OUTPUT 4 OUTPUT 5 4 2 Way DP260 1I INPUT INPUT B 6 Way DP260 II INPUT
5. 0Hz to 20kHz in 1 36 Octave steps Crossover slope can be 6dB 124 I8dB 24dB 36dB and 48dB Octave Filter type can be Butterworth Linkwitz Riley Bessel Out1 Output1 HPF 20 5Hz Butwrth 24dB Frequency Slope Out1 Output1 LPF 20k2Hz Lnk Ril 48dB Frequency Slope Output Parametric EQ Pressing BYPASS will bypass the All bands EQ Out1 Output1 Bypass Bypass The range of frequency is 20Hz to 20kHz in 1 36 Octave The range of Q is 0 4 to 128 The range of gain is 30dB to 1588 in 0 1dB steps Out1 Output1 01 1k00Hz Q 3 0 0 0dB Frequency Q Gain Pressing BYPASS will bypass the current band EQ Out1 Output1 PEQ 01 1 00 2 Q 3 0 0 OdB Br While filter was in BYPASS ON Changing the filter type is achieved by pressing ENTER Out1 Output1 LSF 01 gt hostel 1k00Hz Q 71 0 OdB Frequency Q Gain Out1 Output HSF 01 1k00Hz Q 71 0 OdB OC Gain Output Limiter The limiter on each output has adjustable attack time release time and threshold The range of attack time 0 3 90mS the range of release time 0 to 2 0 second the range of threshold I OdB to 15dB 0 1dB steps Out1 Output1 Limiter A 1 4mS R 2 0S 15dB Attack Release Threshold Output Channel Name For edit channel name by pressing ENTER Cursor will blink on first character position Turn rotary encoder and modify character move cursor position b
6. ervicing to qualified service personal Sevicing is required when the apparatus has been damaged in any way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped The apparatus shall be connected to a MAINS socket outlet with a protective earthing connection Where the MAINS plug or an appliance coupler is used as the disconnect device the disconnect device shall remain readily operable The symbol wherever is appears alerts you to the presense of uninsulated dangerous voltage inside the enclosure voltage that may be sufficient to constitute a risk of shock The symbol wherever is appears alerts you to important operating and maintenance instructions in the accompanying literature Please read the manual To reduce the risk of electric shock do not remove the top cover or the rear section No user serviceable parts inside Refer servicing to qualified personnel To reduce the risk of fire to electric shock do not expose this appliance to rain and moisture The apparatus shall not be exposed to dripping or splashing liquids and no objects filled with liquids such as vases shall be placed on the apparatus These service instructions are for use by qualified service personal only To reduce the risk of electric shock do not perform any servicing other than that contained in the opera
7. m and change Xover mode ENTER to Confirm About Xover mode details see Appendix I PROGRAM MENU Pressing ENTER will enter Save User Program sub menu Save User Program Save User Program Turn rotary encoder to change program index 01 2x3 Way Xover d E Pressing ENTER for confirm and overwrite program ENTER to Overwrite Pressing QUIT for exit 01 2x3 Way Xover Program name length is 6 character Set Prog ram Name Turn rotary encoder and modify character move cursor position 1 2x3 W Xover by pressing BACK or NEXT 0 3 odd Pressing ENTER again for confirm and store program Pressing QUIT for exit ENTER to Save Pressing ENTER for confirm and Save program 01 2x3 Way Xover Saving to Memory 01 2x3 Way Xover PROGRAM MENU Pressing ENTER will enter Delete User Program sub menu Delete User Program Delete User Program Turn rotary encoder to change program index 01 2x3 Way Xover Pressing ENTER ENTER to Delete Pressing ENTER for confirm and delete program 01 2x3 Way Xover Deleting Memory 01 2x3 Way Xover Copy Tools Sub menu Copy Input Section Copy Output Section COPYTOOLS MENU Copy Input Section Copy Input Section Source Target B On Copy Input Section screen Turn rotary FREQ encoder change source channel Turn rotary encoder change target channel Pressing ENTER to confirm and copy intput channel parame
8. n The range of the control over the input gain is 40dB to 6dB in 0 1dB steps InputA Gain Gain 0 OdB Gain Input Parametric EQ Pressing BYPASS will bypass the All bands EQ InputA All EQ Bypass Bypass The range of frequency is 20Hz to 20kHz 1 36 Octave The range of is 0 4 to 128 The range of gain is 30dB to I5dB in 0 1dB steps InputA 01 gt 1k00Hz 3 0 0 OdB Frequency Q Gain Pressing BYPASS will bypass the current band EQ InputA PEQ 01 1k00Hz Q 3 0 0 0dB While filter was in BYPASS ON Changing the filter type is achieved by pressing ENTER InputA LSF 01 z LoShelf 1k00Hz Q 71 0 OdB Frequency Gain HiShelf 1k00Hz Q 71 0 OdB QQ Gain Input Link Set link value for channel while modify parameters the channel of have same link value will modify together Output Gain The range of the control over the input gain is 40dB to I5dB 0 1dB steps Out1 Output1 Gain Output Gain 0 088 Gain Output Polarity The polarity or phase of each output may be switched individually Out1 Output1 Polarity Polarity Oor Output Delay The maximum avaiable delay depend on different devices Out1 Output1 Delay C Delay 0 000 5 x10mS x1mS x10uS 3 43m 343mm 4mm Output Highpass Lowpass Filter The highpass lowpass filter on each output has a frequency range of 2
9. rotary encoder to change parameter Pressing ENTER to confirm and save Change device title name on LCD screen top line Pressing ENTER to edit Device name length is 16 character Turn encoder and modify character move cursor position by pressing BACK or NEXT Pressing ENTER for confirm Pressing QUIT for exit Pressing ENTER again for confirm and store Interface Sub menu INTERFACE MENU Interface Setup Select communication port RS232 Interface Setup Master Source RS232 INTERFACE MENU Protocol Setup Select control protocol Protocol Setup PCsw select PC control Select PCsw Ctrl ESRP select external simple control device Protocol Setup Select ESRP Ctrl Security Sub menu Pressing ENTER will enter Security sub menu Lock status setting No Lock without lock out Control cannot change Display cannot view Xover Only Xover Trim Changes Only Changes View Changes Mutes EVERYTHING Input Gain No Lock No Lock No Lock Control Display Control Display Input PEQs No Lock No Lock No Lock Control Display Control Display Input Links No Lock No Lock No Lock Control Display Control Display Output Gain No Lock Display Display Control Display Control Display Output Delay Display Display Display Control Display Control Display Output PEQs Display Display Display Control Display Control Displa
10. ters COPYTOOLS MENU Copy Output Section Copy Output Section Source 1 Target 2 On Copy Output Section screen Turn rotary FREQ encoder change source channel Turn rotary Q encoder changetarget channel Pressing ENTER to confirm and copy output channel parameters System Sub menu Turn rotary encoder to change LCD contrast Pressing ENTER to confirm and save LCD Contrast Turn rotary encoder to change LED brightness Pressing ENTER to confirm and save Device startup wake up time Mute Hold set to keep mutes on when powered up Wake up Time 0 secs 60 secs set wait time before the audio fades in Turn rotary encoder to change parameter Pressing ENTER to confirm and save Select filter Q or Bandwidth display unit Turn rotary encoder to change parameter Filter Q or BW Pressing ENTER to confirm and save Load Program Option Device Name Title ENTER to Editing Tit Speaker Processor Set Device NameTitle Tit Speaker Processor ENTER to Store Tit Speaker Processor Select delay time or distance Turn rotary encoder to change parameter Pressing ENTER to confirm and save Select output meter indicate style output Level or attenute on limiter Turn rotary encoder to change parameter Pressing ENTER to confirm and save Select load program option AutoMute Force all output mute on after loading program LoadMute Load output MUTE status in program stored Turn
11. tion instructions Repairs have to be performed by qualified service personal CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN DO NOT EXPOSE TO RAIN MOISTURE DRIPPING OR SPLASHING Introduction The DP II Series are powerful DSP based loudspeaker processors ideally suited for install application where they combine the functions of a multitude of conventional products in a compact U unit with extensive remote control capabilities To achieve this the DP Series devices have two inputs three inputs and four inputs and up to eight outputs Base crossover modes 6 Outputs have 2x2 way 2x3 way 4 2 way 5 way and 6 way 4 Outputs have 2x2 way 3 way 4 way and 2 MonoSub Units also offer Source for free assign signal which allows completely flexible routing of any output from any combination of inputs Each input has a gain control multi type filters Filter types included parametric equalisation high amp low shelving Each output has a gain control variable delay line highpass and lowpass crossover filters seven band multi type filters polarity input signal source a limiter The crossover filters offer slopes of up to 48dB Octave Security lock out is avaiable for each parts Supply external device remote controls Remote port is RS232 Front Panel 3 BACK NEXT FREQ a m 00 0 il LOUDSPEAKER MANAGEMENT SYSTEM
12. y HPFs amp LPFs Display Display Display Control Display Control Display Output Links Display Display Display Control Display Control Display Output Phase Display Display Display Control Display Control Display Limiters Display Display Display Control Display Control Display Matrix Gains Display Display Display Control Display Control Display Input Mutes No Lock No Lock No Lock No Lock No Lock Control Control Output Mutes No Lock No Lock Control No Lock No Lock Control Control Output Name Control Control Control Control Control Control Control Menu System No Lock No Lock No Lock No Lock No Lock No Lock Control Memory Store No Lock No Lock No Lock No Lock No Lock No Lock Control Memory Load No Lock No Lock No Lock No Lock No Lock No Lock Control File Operation No Lock No Lock No Lock No Lock No Lock No Lock Control In User Specific setting you can free set up lock status depend on each function part Enter Password Enter Password Confirm Password UnLocking Unit Locking Unit Speaker Processor 2 X 3 Way Xover Pressing ENTER will enter password Turn rotary encoder and modify character move cursor position by pressing BACK or NEXT Pressing ENTER for enter password again while twice time password match system will lock unit Specifications Inputs 2 electronically balanced Impedance gt 10k ohms CMRR gt 75dB 50Hz 10 2
13. y pressing BACK or NEXT Pressing ENTER again for confirm and store channel name Out1 Output1 Name Output1 Source The source on each output can assign signal rounting from input channel create free Xover combination Out1 Output1 Source Source Source Pressing ENTER will switch each input channel mix gain Out1 Output InputA Mix Gain 0 088 MixGain Output Link Set link value for channel while modify parameters the channel of have same link value will modify together Out1 Output1 Link Link None Menu System Pressing MENU will enter menu system Pressing ENTER will enter sub menu MAIN MENU MAIN MENU MAIN MENU MAIN MENU MAIN MENU Interface Sub Menu Security Sub Menu Program Sub menu Load Factory Program Load User Program Design a Xover Save User Program Delete User Program PROGRAM MENU Pressing ENTER will enter Load User Program sub menu Load User Program Load User Program Turn rotary encoder to change program index 01 2x3 Way Xover Pressing ENTER ENTER for Recall Pressing ENTER for confirm and load program 01 2x3 Way Xover Loading New Program 01 2x3 Way Xover PROGRAM MENU Pressing ENTER will enter Design a Xover sub menu Design a Xover Design a Xover Turn rotary encoder to change Xover mode Type 2x2 WAY XOVER Pressing ENTER for confir

Download Pdf Manuals

image

Related Search

Related Contents

pdf file 2.47 Mb  取扱説明書  3M X62w  Cisco Systems OL-3995-01 User's Manual  PHOBOS N - Fast Access Security Corp.  Manual do Proprietário  Get Datasheet - Chroma Systems Solutions  Manual de instrucciones  kit de renovation baignoires et carrelages  Mode d`emploi Fers Vapeur Ultragliss Cordless  

Copyright © All rights reserved.
Failed to retrieve file