Home
- Divelbiss Corporation
Contents
1. This section describes the SI APPMOD Times4 Application Module including input output assignments and an opera tional description GETTING TO KNOW THE MODULE Status O 600 ti 12 13 14 Programming r Setpoint Variable Display g peppaquiz diy e uo 660 667 4 Waed NOILVYOdY09 mOFE YSN O1N0 umopouapasd WOD SSIQI Ap MMMy dYyY SSIQJ SAI hd 1 75 a 2375 4 The module is connected to external devices via its included mounting socket Connector Pin out Bottom View Solves lIt Connector Pin 1 Channel 2 Output Pin 2 Channel 1 Output Pin 3 Timer Channel 1 Enable Pin 4 Timer Channel 2 Enable Pin 5 Timer Channel 3 Enable Pin 6 Timer Channel 4 Enable Pin 7 Earth Gnd Pin 8 Input Power Common Pin 9 10 24 5VDC_ Input Power Pin 10 Channel 4 Output Pin 11 Channel 3 Output Figure 2 1 Module Pin Out SI APPMOD Times4 User Manual Document 2008011 0 pdf Page 3 of 9 Divelbiss Corporation 9778 Mt Gilead Rd Fredericktown Ohio 43019 1 800 245 2327 www divelbiss com I oY 0 f hy easy MODULE MOUNTING The Module mounts to an industry standard 11 pin Octal relay socket To mount the module align with the socket and firmly push into position MODULE INPUT POWER The module can be powered with 10 24 5VDC The input power must be of sufficient supply to drive the module and the outputs based on the load currents for each Maximum current for the modu
2. As the module is based on the Solves It Model SI 200 the program can be customized and its functionality expanded Accessories are required The program that was factory installed can be downloaded from http www divelbiss com The program can be edited to add additional functionality and logic To gain functionality of some inputs and or outputs it may be necessary to re assign the I O that was factory configured For more information about changing the functionality download the Solves lt User Manual and the EZ LADDER User Manual The following accessories are required to re program the module and are included in the SIAPPMOD PGMkIT 1 SI PGM 2 EZLDCD 02 PROGRAMMED FROM FACTORY SPECIFICATIONS Solves lt Programming Cable EZ LADDER Lite on CD Processor Solves It Model 200 Based on PLC on a Chip Memory 64K Flash Outputs 4 Sourcing SSR Outputs rated 10 24VDC 300mADC Max each Max total output load Power Requirements 1ADC 24VDC power input Output Voltage Input Power Functionality Channel 1 4 Output 10 24 5VDC 150mADC Max Indicators 11 14 LED Indicator 1 Status LED Indicator Digital Inputs 4 Sourcing Inputs Channels 1 4 Enable Display 4 Digit 7 Segment Programmable LED Display Push Buttons 2 Programmable Push Buttons Operating Temp 0 60 C Dimensions 3 62 Wide x 5 21 Length x 1 21 Tall Mounting Plugs into Industry standard 11 pin Octal Relay Socket Type Plastic Housing SI A
3. S APPMOD Times4 SOLVES IT 4 CHANNEL TIMER APPLICATION MODULE Revision 0 for Software Version 1 0 0 0 ae PLC on a Chip Patent 7 299 099 A larger format of this manual may be found at http www divelbiss com E E 9778 Mt Gilead Rd Fredericktown OH 43019 Toll Free 1 800 245 2327 Web http www divelbiss com Smart Parts for Managing Automation Email sales divelbiss com 2008011 0 TABLE OF CONTENTS Table of Contents Page 1 Package Contents Page 1 Getting Started Page 2 How to Use this Manual Page 2 SI APPMOD Times4 Basics Page 3 Get to Know the Module Page 3 Module Mounting Page 4 Module Input Power Page 4 Module Operation Page 5 User Interface Page 5 Enable Input Connections Page 6 Output Connections Page 6 Viewing Elapsed Timer Values Page 7 Configuring the Channels Page 7 Expandability Customization Page 9 Programmed from Factory Specifications Page 9 WARNING The SI APPMOD TIMES4 as with programmable controllers must not be used alone in applications which would be haz ardous to personnel in the event of failure of this device Precautions must be taken by the user to provide mechanical and or electrical safeguards external to this device This device is NOT APPROVED for domestic or human medical use PACKAGE CONTENTS Whats Included Qty Description Part Number Location 1 SI 200 with Software Pre loaded SI 200 In Box 1 SI APPMOD TIMES4 Manual 200801
4. at Buyer s expense Warranty of repaired or replacment products will be limited to ninety 90 days or the remainder of the original warranty whichever is greater Warranty is available only if Divelbiss Corporation is promptly notified in writing upon discovery of any alleged defect and examination of the subject product discloses to Divelbiss satisfaction that any defect has not been caused by misuse neglect improper installation improper operation improper maintenance repair or alteration accidents or unusual deterioration or degradation of the equipment or parts thereof due to physical environment or due to electrical or electromagnetic noise environment This warranty is in lieu of all other warranties expressed implied or statutory including warranties of merchantability or fitness for a specific purpose
5. the configuration menu Pressing the B1 button will enter the configuration menu Indicators 11 14 will indicate which menu item is currently being viewed modified The menu number is displayed on these indicators using Binary Coded Decimal BCD When in the configuration Menu Q the indicator s will flash this BCD Figure 2 6 illustrates BCD and it s corresponding menu item Please note for illustra tion purpses the 11 14 indicators are shown on steady but in reality they will be flashing SI APPMOD Times4 User Manual Document 2008011 0 pdf Page 7 of 9 Divelbiss Corporation 9778 Mt Gilead Rd Fredericktown Ohio 43019 1 800 245 2327 www divelbiss com I oY 0 2 f hy ea MENU ITEM FUNCTION BINARY CODED DECIMAL MENU ITEM FUNCTION BINARY CODED DECIMAL 1 CH 1 ON DELAY CH 3 ON DELAY 1 1 OFF DELAY O O O OFF DELAY O O 12 11 12 13 14 2 CH 1 TIMER 1 CH 3 TIMER 1 1 SETPOINT O O O SETPOINT O O 12 11 12 13 14 3 CH 2 ON DELAY s i CH 4 ON DELAY i g g OFF DELAY O O OFF DELAY O 12 11 12 13 14 4 CH 2 TIMER CH 4 TIMER i SETPOINT O O O SETPOINT O O O 11 12 13 14 11 12 13 14 a o N O UNLIT LED FLASHING LED Figure 2 6 LED Indicator Binary Coded Decimal If the LED is on steady then the module is displaying an elapsed timer value and is not in the configuration menu In the timer view mode 11 on steady indicates the Channel 1 Timer is displayed 12 on steady indicat
6. 1 X In Box 1 Din rail Socket 115 105328 In Box 4 Commutating Diodes 111 101012 In Box SI APPMOD Times4 User Manual Document 2008011 0 pdf Page 1 of 9 Divelbiss Corporation 9778 Mt Gilead Rd Fredericktown Ohio 43019 1 800 245 2327 www divelbiss com GETTING STARTED This section explains how to read this manual and understand the symbols HOW TO USE THIS MANUAL In this manual the following conventions are used to distinguish elements of text BOLD Denotes labeling commands and literal portions of syntax that must appear exactly as shown italic Used for variables and placeholders that represent the type of text to be entered by the user SMALL CAPS Used to show key sequences or actual buttons such as Ok where the user clicks the OK button In addition the following symbols appear periodically in the left margin to call the readers attention to specific details in the text Warns the reader of a potential danger or hazard that is associated with certain actions Q Appears when the text contains a tip that is especially helpful Indicates that the text contains information to which the reader should pay particularly close attention All Information and Specifications Subject to Change without Notice SI APPMOD Times4 User Manual Document 2008011 0 pdf Page 2 of 9 Divelbiss Corporation 9778 Mt Gilead Rd Fredericktown Ohio 43019 1 800 245 2327 www divelbiss com MODULE BASICS
7. Ohio 43019 1 800 245 2327 www divelbiss com I oY 0 2 f Ky ea ENABLE INPUT CONNECTIONS The Enable inputs for each channel are sourcing therefore requiring a sinking device be connected When the input is connected to common shorted to common the input is energized Figure 2 4 provides a sample connection As shown in Figure 2 4 switches are used to illustrate what is required although any device that operates the same may be used V DC POWER COMMON Status oddi Programming r Setpoint Variable Display 71 ENABLE CH 1 O Q ENABLE CH 2 O Q ENABLE CH 3 Q Q ENABLE CH 4 Figure 2 4 Enable Input Connections OUTPUT CONNECTIONS When outputs are energized the output pin will be sourced with V equal to the module input power voltage Each output can drive a load up to 300mA maximum resistive Depending upon the device connected to an output a mini mum load resistor may be required If the output is energized at all times connect a 4700 to 1KQ load from the output to common Figure 2 5 is a typical output wiring diagram The factory installed software for this module will only allow four outputs to be energized at a time Max total current for simultaneous outputs is 1ADC Simultaneous output loads greater than 1A may result in damage to the module Care must be taken to ensure the loads connected to the outputs if all channels are used does not exceed 1A SI APPMOD Times4 User Manua
8. PPMOD Times4 User Manual Document 2008011 0 pdf Page 9 of 9 Divelbiss Corporation 9778 Mt Gilead Rd Fredericktown Ohio 43019 1 800 245 2327 www divelbiss com Limited Warranty Divelbiss Corporation warrants equipment will be free from defects in material and workmanship for a period of one 1 year from the date of the Divelbiss invoice that the equipment was furnished Divelbiss Corporation will not be liable for any design furnished by Buyer and incorporated into the equipment In no event shall Divelbiss Corporation be liable for anticipated profits consequential damages or loss of use of equipment or of any installation into which the equipment covered by this order may be put Divelbiss Corporation shall not be liable or responsible for any loss injury or damage resulting directly or indirectly from the use of software and or programming in any way associated with the equipment of this order Obligations are to be limited to the repair or replacement at the Divelbiss Corporation plant Fredericktown Ohio upon return of the part or component in question prepaid by Buyer The return freight charges to be paid by Divelbiss The part or component is only to be returned to Divelbiss with a Returned Material Authorization number issued by the Divelbiss Service Department Any warranty service consisting of time travel and expenses related to such services performed other than at Divelbiss Corporation plant shall be
9. es the Channel 2 Timer is displayed 13 on steady indicates the Channel 3 Timer is displayed and 14 on steady indicates the Channel 4 Timer is displayed SETTING THE TIMER TYPE ON OFF DELAY 1 Using the B1 button cycle through the configuration menu until the desired menu item is displayed 1 3 5 7 depending upon channel Refer to Figure 2 6 for menu items Verify the correct menu item per the indicator LEDs 2 The type will either be displayed as a 0 indicating ON DELAY or 1 indicating OFF DELAY Press the B2 button to toggle this setting between 0 and 1 The setting is stored each time the B2 is pressed Press repeatedly to exit the configuration menu if all changes have been completed SETTING THE TIMER SETPOINT 1 300 SECONDS 1 Using the B1 button cycle through the configuration menu until the desired menu item is displayed 2 4 6 8 depending upon channel Refer to Figure 2 6 for menu items Verify the correct menu item per the indicator LEDs 2 Press the B2 button repeately to increment the setpoint time in 1 second increments Pressing and holding the B2 button will cause the rate of the increment to increase The time will increase to 300 seconds then reset and begin from zero SI APPMOD Times4 User Manual Document 2008011 0 pdf Page 8 of 9 Divelbiss Corporation 9778 Mt Gilead Rd Fredericktown Ohio 43019 1 800 245 2327 www divelbiss com X 0 2 f hy ea EXPANDABILITY CUSTOMIZATION
10. l Document 2008011 0 pdf Page 6 of 9 Divelbiss Corporation 9778 Mt Gilead Rd Fredericktown Ohio 43019 1 800 245 2327 www divelbiss com I oY 0 E CHANNEL 4 OUTPUT 1 ee LOAD DEVICE CHANNEL 3 OUTPUT LOAD DEVICE DC POWER EARTH COMMON GND CHANNEL 2 OUTPUT r ges 12 13 14 CHANNEL 1 OUTPUT Programming Setpoint Variable Display LOAD DEVICE Port rs Output Voltage will be equal to Input Voltage on Pin 9 Figure 2 5 Typical Output Connections VIEWING ELAPSED TIMER VALUES Elapsed timer values for each channel can be viewed on the display As a default on power up Channel 1 s current elapsed time is shown I1 is on steady indicating channel 1 To see other channels press the B2 button until the cor rect indicator led is on steady 11 on steady indicates the Channel 1 Timer is displayed I2 on steady indicates the Channel 2 Timer is displayed I3 on steady indicates the Channel 3 Timer is displayed and 14 on steady indicates the Channel 4 Timer is displayed According to the indicator shown the corresponding channel s elapsed time will be dis played CONFIGURING THE CHANNELS All channels are configured as on delay and timer setpoints are defaulted to zero from the factory Each channel will Q need to be configured before the module will function properly UNDERSTANDING THE INDICATORS To be able to configure the module channels you must first understand
11. le is 150mADC and maximum load for each outputs is 300mADC For the pre programmed software 4 outputs are used and may be on ata time Exceeding a total output load of greater than 1ADC more than 3 outputs at full load simultaneously can damage the module 10 24 5VDC POWER IN DC POWER COMMON Status O 0000 I1 12 13 14 Programming Setpoint Variable Display APPLICATION MODULE Port INPUT POWER Shown installed in provided mounting socket B1 gt SI 2000 Figure 2 2 Module Input Power Diagram SI APPMOD Times4 User Manual Document 2008011 0 pdf Page 4 of 9 Divelbiss Corporation 9778 Mt Gilead Rd Fredericktown Ohio 43019 1 800 245 2327 www divelbiss com X 0 2 f Ky ea MODULE OPERATION The SI APPMOD Times4 module provides four independent timer channels Each channel may be configured as either an on delay or off delay timer Each channel is controlled by an enable input and has an output The output functionali ty is based on the configuration of the timer on delay or off delay Each timer channel setpoint can be adjusted from 1seconds to 300 seconds and must be configured as either on delay or off delay The setpoint and timer type are set using the user interface ON DELAY Operation When the module sees the Enable energize the timer begin timing When the setpoint is reached the channel Output is energized If at any point the Enable is de energized the actual
12. shing 12 13 it is the 8 digit of the binary coded decimal BCD indicating which menu item is displayed Status 5 Module Status Indicator Flashing slowly indicates module problem Flashing quickly indicated module is operating 6 B1 Push button Each press will cycle one step through the module setup menu The menu is displayed using the flashing 11 14 indicators in BCD 1 Channel 1 Type 0 On delay 1 Off delay 2 Channel 1 Timer Setpoint 1 300s 3 Channel 2 Type 0 On delay 1 Off delay 4 Channel 2 Timer Setpoint 1 300s 5 Channel 3 Type 0 On delay 1 Off delay 6 7 8 Programming r Setpoint Variable Display 7 Port Channel 3 Timer Setpoint 1 300s Channel 4 Type 0 On delay 1 Off delay Channel 4 Timer Setpoint 1 300s 8 Setpoint Variable Display 7 B2 Push button View the current elapsed time values configure the timer When not in the setup menu indicator LEDs on steady each press channels and setpoints cycles through which channel s current elapsed time is displayed 11 14 represent channels 1 4 respectively In the setup menu this button will either the type of timer channel 0 or 1 or increment the timer value in seconds Holding the button longer increases the speed which the timer setpoint increments Figure 2 3 User Interface SI APPMOD Times4 User Manual Document 2008011 0 pdf Page 5 of 9 Divelbiss Corporation 9778 Mt Gilead Rd Fredericktown
13. timer value will reset and the Output will de energize if energized On Delay is the default factory setting OFF DELAY Operation When the module sees the Enable energize the Output is energized When the Enable is then de energized the timer begin timing When the setpoint is reached the channel Output is de energized If at any point the Enable is re ener gized the actual timer value will reset and the Output will energize if de energized USER INTERFACE The user interface consists of two push buttons labeled B1 and B2 the Setpoint Variable Display four LED indicators 11 14 and the Status LED indicator 1 Indicator 1 2 Indicator 2 On Steady indicates that current elapsed time of Channel 1 is On Steady indicates that current elapsed time of Channel 2 is displayed on the Setpoint Variable Display When flashing displayed on the Setpoint Variable Display When flashing it is the 1 digit of the binary coded decimal BCD indicating it is the 2 digit of the binary coded decimal BCD indicating which menu item is displayed which menu item is displayed 3 Indicator 3 On Steady indicates that current elapsed time of Channel 3 is displayed on the Setpoint Variable Display When flashing it is the 4 digit of the binary coded decimal BCD indicating which menu item is displayed 4 Indicator 4 On Steady indicates that current elapsed time of Channel 4 is displayed on the Setpoint Variable Display When fla
Download Pdf Manuals
Related Search
Related Contents
Samsung SP-A400B Bruksanvisning Lindy 25045 User's Manual 7 CHRS Limoges RAF Socianalytique Rapport De La 2e Phase 2013. Kingston Technology HyperX Memory HyperX 1GB 400Mhz DDR 2pk AIX Logical Volume Manager from A to Z: Troubleshooting and Hip Street HS-IPSP1001 User's Manual DOC TECHNIQUE ( 1743 Ko) Canon DR-7080C Owner's Manual BIOXEDA Copyright © All rights reserved.