1. CD10L CD20L 1Ph 220 240V 50Hz 1Ph 220 240V 50Hz Dehumidifying capacity 10 L day at 309 C 20 L day at 309 C aan Fe Fo EE 35 80 35 80 Airflow m3 h Noise level dB A 4 48 CS Cs WxDxH WxDxH Net Gross weight kgs 10 5 11 5 14 15 5 All information provided is for reference only Products specifications may change due to continuous product development Disposal Do not dispose this product as unsorted waste Collection of such waste must be handled separately as special treatment is necessary Recycling facilities are now available for all customers at which you can deposit your old electrical products Customers will be able to take any old electrical equipment to participating sites run by their local councils Please remember that this equipment will be further handled during the recycling process so please be considerate when depositing your equipment Please contact the local council for details of your local household waste recycling centres zen ElectriQ UK SUPPORT www ElectriQ co uk support Please for your own convenience make these simple checks before calling the service line 1 Has the unit been standing upright for at least 2 hours 2 Is the unit plugged into the mains 3 s the fuse OK 4 Switch the unit off and wait three minutes to see if the issue is resolved Restart the unit 5 Check if the water tank is full If the unit still fails to operate call 0871 62
2. electro Digital Dehumidifier with Humidistat CD10L 10 litres per day CD20L 20 litres per day USER MANUAL DO e SOOO A x4 e LC Thank you for choosing ElectriQ Please read this user manual before using this innovative Dehumidifier and keep it safe for future reference Visit our page www electriQ co uk for our entire range of Intelligent Electricals Contents SJLebInsStEUCHODS pesei er er diaet X dm idis Installation 2 Parts and Control Panel deside eee PERRA EHE OinckTelerencee gude aasivukeseki rid EE bed ere ru tin POSMIOMINS 5 3sexebusicEssatA NUN S nstedctped REM WatepDrandPe mudtssEoE SIR tauP vanus nd Care and Maintenance csse ren Troubleshooting unieceestbkhesurkeeE S ROCEEYM Ex Technical Data inse cate beese cece desde SAFETY INSTRUCTIONS Important e Carefully read the instructions before operating the unit e This appliance is for indoor use only e Rating This unit must be only connected to a 220 240 V 50 Hz earthed outlet e Installation must be in accordance with regulations of the country where the unit is used e f you are in any doubt about the suitability of your electrical supply have it checked and if necessary modified by a qualified electrician e This dehumidifier has been tested and is safe to use However as with any electrical appliances use it with care e Disconnect the power plug from socket be
3. upright otherwise irreparable damage may be caused to the compressor if in doubt we suggest waiting at least 24 hours before starting the unit e Avoid restarting the dehumidifier unit unless 5 minutes have passed since being turned off This prevents damage to the compressor e Never use the mains plug as a switch to start and turn off the dehumidifier Use the provided ON OFF switch located on the control panel e Always place the unit on a dry and as surface e The appliance should not be installed in laundry or wet rooms where the humidity is higher than 8596 RH e Do not dry laundry above the unit to prevent water entering the dehumidifier Place the laundry at least 1 meter away from your dehumidifier e Do not place the unit next to heat sources e g Electrical fires fireplaces etc Energy Saving and Unit Safety Protection Tips e Do not cover or restrict the airflow from the outlet or inlet grills e For maximum performance the minimum distance from a wall or objects should be 20 cm e Keep the filters or grills of the unit clean Under normal conditions filters or grills Should only need cleaning once every three weeks approximately Since the filters remove airborne particles more frequent cleaning maybe necessary depending on the air quality Vacuum and wash the mesh filters with hot soapy water and dry them before placing them back in the unit Installation Remove any water from the water tank before starting the un
4. 0 1057 or complete the online form Office hours 9AM 5PM Monday to Friday www ElectriQ co uk Unit 2 The Nursery Berristow Lane South Normanton Derbyshire DE55 2FX 10
5. Clean the Grille and Case Use water and a mild detergent Do not use bleach or abrasives Do not splash water directly onto the main unit Doing so may cause an electrical shock and can lead to the insulation to deteriorate or cause the unit to rust The air intake and outlet grilles get soiled easily so use a and push it upward vacuum attachment or soft brush to clean Fig 10 Pull out the filter Insert the filter downward 2 Clean the water tank Every few weeks clean the tank to prevent growth of mould mildew and bacteria Partially fill the tank with clean water and add a little mild detergent Swish it around in than empty the tank and rinse NOTE Do not use a dishwasher to clean the tank After cleaning and drying the tank must be reinserted securely into dehumidifier in order to restart operation Fig 13 Frequently Asked Questions Why doesn t the dehumidifier seem to extract much water if the temperature is low This is a compressor dehumidifier which works best in temperatures above 15 C If the temperature is low and the air is dryer than the setting on the humidistat the unit will not extract water If you want to use a dehumidifier for outside buildings unheated properties boats or garages please check our desiccant range Why doesn t the unit work or stops suddenly The water tank may be full or displaced To rectify empty the tank and carefully place the tank back in the unit The unit may be run
6. fore dismantling assembling or cleaning e Avoid touching any moving parts of the appliance e Never insert fingers pencils or any other objects though the guard e This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities It is also not intended for use by those with a lack of experience and knowledge unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety e Do not leave children unsupervised with this appliance e Do not clean the unit by spraying it or immersing it in water e Never connect the unit to an electrical outlet using an extension cord If a power outlet is not available one should be installed by a qualified electrician e Never operate this appliance if the cord power adapter or plug is damaged Ensure the power cord is not stretched or exposed to sharp object edges e A damaged power supply cord should be replaced by the manufacturer or a qualified electrician in order to avoid a hazard eAny service other than regular cleaning or filter replacement should be performed by an authorized service representative Failure to comply could result in a voided warranty e Do not use the appliance for any other purposes than its intended use e Do not tilt the unit while in use The unit is design to work only in vertical position e This dehumidifier must always be stored and transported
7. he power resumes Wait at least 3 minutes before resuming operation Power After the unit has stopped it cannot resume operation in the first 3 minutes This is to protect the compressor Operation will automatically start after this period lapse LCD Display While using the Up and Down Keys it shows the selectable humidity level in Relative Humidity RH as a percentage then shows the actual room humidity level with a 596 accuracy Your CD10L and CD20L dehumidifiers are advanced micro CPU controlled devices able of self diagnostics The LCD display will also show the error and protections codes Please consult the troubleshooting section at the end of this user manual 4 Positioning the dehumidifier A badly positioned dehumidifier will have little effect in effectively drying the place In positioning the dehumidifier please ensure circulation of air in not restricted around the unit Please observe figure 4 in installing the unit 40cm or more i QOePcOOoOoDOOo00 ir outlet grille Air intake grille vig 20cm or more INS 20cm or more J j Es jj al 20cm or more x 20cm or more Fig 4 Allow at least 20 cm space around the unit This dehumidifier is designed only for indoor residential office applications and any commercial or industrial use will invalidate the warranty Place the dehumidifier on a flat dry surface The dehumidifier must be operated in an enclosed area to be most effecti
8. it In order to save energy do not open windows or doors while the unit is running Place the unit on a hard flat surface On first use run the unit continuously for 24 hrs To reduce noise levels Place a piece of carpet or a rubber mat under the unit to reduce any vibrations while the unit is running CD10L and CD20L dehumidifiers uses compressor technology to extract water from the environment The compressor dehumidifiers are ideal for normal domestic or office environment which heated during the winter months with temperatures above 12 15 C CD10L and CD20L are easy to move around on castors and are intelligent dehumidifiers which will extract unwanted humidity while saving money due to their humidistat and power saving logic CD10L and CD20L features an intelligent humidistat which is adjustable in increments of 596 from 35 8096 RH insuring your room is not dried too much and power is not wasted CONTROL PANEL 1 Control panel 2 Air Intake grill 3 Water tank 4 Mesh filter behind air intake grill 5 Carrying Handle 6 Air outlet grill 7 Power cord band use when storing only 8 Permanent drainage outlet 9 Power cord 10 Power plug varies according to region 1 Power ON indicator light green 2 Tank full indicator light red 3 Continuous on indicator light green 4 Continuous Laundry Mode On Off 5 Humidity Level LCD Display 6 Power On Off Key 7 Humid
9. ity Controls Up Down Keys Quick Reference Guide Power Key 6 Press to turn the dehumidifier on and off Humidity Controls Up Down Keys 7 humidity level can be set within a range of 3596 RH Relative Humidity to 8096 RH in 596 increments Ideal setting is 5096 For drier air press the key DOWN and set to a lower percent value For allowing more moisture in the air press the key UP and set to a higher percent value Continuous Laundry Mode On Off 4 Select for the dehumidifier to operate continuously for maximum water extraction until the tank is full The Humidity set control keys cannot be used when continuous operation is on Press this pad again to cancel Continuous operation Other features and Indicators Tank Full Light Blinks when the tank is ready to be emptied or when the tank is remove or not replaced in the proper position Auto Defrost When frost builds up on the evaporator coils the compressor will cycle off and the fan will continue to run until the frost disappears The Auto Defrost indicator light will blink Auto Shut Off The water level control switch shuts off the dehumidifier when the tank is full or when the tank is removed or not replaced in the proper position When the selected humidity is reached the unit will be shut off automatically Auto Restart on some models If the unit stops off unexpectedly due to the power cut it will restart with the previous function selected automatically when t
10. may cause the unit not to operate 2 Continuous draining Water can be automatically plumbed in or drained into sink a larger recipient or through the wall into an outside drain by attaching a pipe to the unit 12mm diameter not included Pull out the rubber plug from the drain outlet in the back of the unit Then insert the pipe into the drain outlet at the back of the unit as shown in Fig 8 Make sure the connection between pipe and the drain outlet is tight and po x do not leak Then direct the pipe to a suitable drainage o E point This unit uses gravity fall to dispose water hence the drain should be lower than the dehumidifier water outlet ose from the Be sure to run the water pipe downward and let the water drain outlet to flow out smoothly Do not kink or bend the pipe as shown in Fig 9 NOTE When the continuous drain feature is not being used remove the drain hose from the outlet and attach the rubber plug back to the drain outlet The permanent drain can be used in conjunction with water pump e g when draining a cellar to lift the water upwards Fig 8 Care and Maintenance Always shut off the unit and unplug from the mains before cleaning or performing any maintenance When it is not in use for long periods it is advised to remove the plug from the plug socket Do not use chemical solvents such as benzene alcohol or gasoline as they may cause irreversible damage to the unit 1
11. ning in dehumidifying mode with a low room temperature Please check if the room temperature is lower than 5 9C If so the unit will stop working while in dehumidifying mode E2 low temperature error or P1 defrosting should show on the display The ambient operating range is between 59C and 35 C with a relative humidity ranging from 30 to 8096 For maximum efficiency use the unit between 15 C and 32 C Sometimes cold and or hot air comes out from the air outlet grill why When the unit is in dehumidifying mode it absorbs humid air from room and freezes it to reduce the humidity During the cold cycle there should be cold air coming out of the unit During the defrost cycle hot dry air should be coming out of the outlet grill Troubleshooting Issue Cause Solution Hot or cold air Normal Operation When the unit is in dehumidifying being produced mode it absorbs humid air from room and freezes it to reduce the humidity During the cold cycle there should be cold air coming out of the unit During the defrost cycle hot dry air should be coming out of the outlet grill Unit does not Is the plug properly Insert the plug into the socket and turn operate inserted in the socket the switch on Does the tank full indicator Tank full float displaced or tank not flash properly inserted P2 Empty tank check float and make sure tank is properly inserted in unit Dehumidifier Is the unit set to a humidity Set the humidit
12. ve Close all doors windows to create the best operating environment Do not use outdoors Note Castors can only move laterally Do not force castors to move over carpet nor move the unit with water in the tank as it may tip over and spill water Water Drainage When the water tank is full the unit will stop automatically When this happens the P2 code will show on the LCD panel Note Only empty the water tank when is full or before moving or storing the unit There are two ways to dispense collected water i Bull outifis paketais 1 Use the tank When the tank is full the unit will automatically stop running and the Full indicator light will flash Slowly pull out the tank Grip the left and right handles securely and carefully pull out straight so water does not spill Do not put the tank on the floor because the bottom of the tank is uneven and tank will fall and cause Fig 5 the water to spill Empty the water tank and reinsert it into the dehumidifier The tank must be in place and securely iaa ierat and pull seated for the dehumidifier to operate again The out from the unit dehumidifier will re start when the tank is restored in its correct position NOTES When you remove the bucket do not touch sensors or any parts which are situated behind tank Doing so may damage the product Be sure to push the tank gently all the way into the unit Banging the bucket against anything or failing to push it in securely into place
13. y level on the humidistat does not extract level lower than the one in bellow current humidity reading water the room Is the temperature too low Increase temperature in the room or for water extraction to be reposition the unit efficient Is any intake grill or Remove obstructions and restart the discharge blocked Is the unit unit too close to walls Ensure a distance of at least 20 cm between the unit amp walls Airflow seems Is filter dirty or clogged Please service the filters regularly as per weak user manual Unit is noisy Is the unit on uneven Please place on flat horizontal surface during operation surface Is filter clogged Please service the filters regularly as per user manual E1 on LCD Humidity sensor error Unplug the unit and plug it back in If error repeats call for service centre E2 on LCD Temperature sensor error Unplug the unit and plug it back in If error repeats call for service centre 8 P1 on LCD Unit is defrosting Allow the unit to automatically defrost The protect will clear after the unit self defrosts Increase temperature in the room if P1 repeats too ofter P2 on LCD Water tank full notification Tank is full or is not in the right indi position Empty the tank and replace in the right position Any other malfunctions will need to be reported to ElectrlQ service centre Do not attempt unauthorised repairs as these may invalidate the warranty Technical data
Download Pdf Manuals