Home

CP5-Series User Manual

image

Contents

1. ALUS American Weigh Scales PC Series User Manual lt PC 201 200g x 0 01g PC 2000 2000g x 0 1g Copyright 2014 American Weigh Scales Inc All rights reserved Rev 1 0 PC Series Manual Thank you for purchasing the American Weigh PC Series digital pocket scale Please read all operating instructions carefully before use Scales are precision measuring devices and should always be handled with proper care To ensure years of reliable service keep these simple tips in mind Do not exceed the scale s maximum capacity This scale has integrated overload protection but any overload protection has its limits i Avoid exposure to extreme heat or cold Scales perform best at normal room temperature If temperatures have changed dramatically recalibration may be necessary Allow your scale to warm up for 30 60 seconds before performing calibration if available Store your scale in a clean dry location Dust dirt and moisture can accumulate on the weighing sensors and electronics causing inaccuracy or malfunction Avoid using your scale in close proximity to strong radio wave emitting devices such as cordless phones Always weigh on a flat and level surface free from vibrations and drafts The corner of a room is usually the most stable Gently apply all items to be weighed Do not drop items onto the weighing platform Avoid dropping your scale The warranty does not cover dama
2. ge due to rough treatment or overload Check the batteries first if you are having any trouble with your scale This simple step can remedy most scale issues Calibration should be checked and adjusted occasionally as part of routine scale maintenance I Part List 1 Scale 2 Cover Tray 3 AAA Batteries x2 Il Key Description TARE Sets the displayed weight to zero ON OFF Turns the scale on or off MODE Changes the display weighing unit CAL Enters calibration See Section IX M Enters unit price setup mode SO Ne K Selects the current unit price preset 1 7 7 Numeric Keys 0 9 DEL Enters unit price lll Battery Installation T E amp E e Proper Battery Orientation PC Series Manual Low batteries can cause inaccuracies in digital scales If you are experiencing issues with your scale first try new batteries Most times this will solve the problem 1 Before using the scale for the first time check the battery compartment and remove any plastic insulation strips or packaging that may be in place to prevent battery drainage during shipping storage 2 If you are replacing the batteries make sure the positive and negative contacts are properly aligned IV Basic Operation 1 Place the scale on a flat level surface and press the ON OFF key to turn the scale on 2 Once the start up process completes and the scale goes to zero you are ready to weigh 3 Place the
3. nual problem persists the load cell may be permanently damaged due to overloading 2 O Ld Overload The maximum capacity has been exceeded Remove the extra weight to avoid permanently damaging the load cell 3 Lo Batteries are low Replace the batteries XIII Specifications PC 2000 Capacity 2000g 0 1g 0 03g 0 2g 2 x 1 5V AAA Alkaline Dimensions 0 9 x 5 0 x 6 4 in Platform Dimensions 4 4 x 4 8 in Warranty 10 Year Limited Warranty XIV Capacity Readability Charts PC 2000 200g x 0 01g 2000g x 0 1g 7 0550z x 0 0010z 70 550z x 0 010z 6 430ozt x 0 0010zt 64 30o0zt x 0 010zt 128 60dwt x 0 01dwt 1286 0dwt x 0 1dwt 1000ct x 0 05ct 10000ct x 0 5ct 3086 4gn x 0 2gn 30864gn x 2gn American Weigh Scales Inc Norcross GA 30092 Made In China to our exact specifications and quality control
4. quantity to be weighed onto the weighing platform 4 Wait a couple seconds for the display to stabilize before taking a weight reading 5 To turn the scale OFF press the ON OFF key again V Changing the Unit of Measure 1 Press the MODE key to change the scales displayed unit of measure 2 If the scale is turned off then back on it will default to the last unit used PC 201 amp PC 2000 Units g gram oz ounce gt ozt troy ounce dwt pennyweight ct carat gn grain VI Using the Tare Feature You can use this scale s tare feature to subtract the weight of an empty container or vessel for net weight determination NOTE The weight of the container will subtract from the available capacity subtractive taring 1 Place the empty container or vessel on the weighing platform 2 Press the TARE key The display will then reset to zero after a couple seconds If the container is removed its weight will be displayed as a negative number 3 You may now fill the container with the quantity to be weighed The display will show the net weight of the contents 4 To return to normal weight display gross weight remove any items from the weighing platform and press the TARE key again to re zero the scale Vil Unit Price Setup The price computing mode allows you to store up to 7 unit price presets to use for price calculation This scale s price computing mode is for personal use only and is no
5. t legal for trade 1 Press the K button to select a preset to change 1 7 2 Press the M key The preset number will flash 3 Use the numeric keypad to enter the desired unit price Press DEL to delete if you make a mistake 4 Press M again to confirm The display will now show the unit price weight and total price 5 Press MODE if you wish to change the weighing unit PC Series Manual Vill Price Computing 1 Press the K key to select a unit price preset 2 Place the item to be weighed on the platform 3 The display will show the unit price weight and total price 4 Press MODE if you wish to change the weighing unit IX Calibration Initial calibration is performed at the factory However the calibration can drift slightly due to stresses from shipping Also due to changes in local acceleration of gravity around the world adjustment is recommended when moving the scale from one location to another To check calibration 1 Place the required calibration weight on the scale and note the displayed value 2 If the displayed value is not within acceptable tolerance see chart on next page adjustment is required Model EER Calibration Recommended Tolerance Weight Accuracy Class PC 201 0 02g 200g OIML M2 PC 2000 0 2g 2000g OIML M2 X Adjustment WARNING If you do not use the correct weight listed in the above chart for your scale you WILL miscalibrate and lose the factory calibration Calibration req
6. uires an accurate weight 1 Press the CAL button to enter calibration mode The display will show CAL 2 Make sure no weight is on the platform then tap 3 4 the CAL key again to set the zero point The LCD will flash CAL followed by the required calibration weight again see chart on previous page Place the required weight on the center of the scale platform The display will flash PASS then return to normal weighing NOTE PASS only indicates that calibration has completed and is not a confirmation that you have used the correct weight Test the accuracy by placing the same calibration weight back on the platform and checking the value If the value is within the acceptable tolerance limit calibration is complete If not try repeating calibration under more stable conditions XI Troubleshooting xII 1 Problem Scale will not turn on Solution Check the batteries and battery contacts Problem Displayed weight fluctuates randomly Solution Make sure your workspace is stable and free of any air currents vibration and static electricity Nearby radio wave emitting devices can cause fluctuations Problem Displayed weight is inaccurate Solution Perform a calibration adjustment If you are still having trouble contact our warranty department Error Codes OUTZ Zero point has drifted out of the acceptable range Try to perform a calibration adjustment If the PC Series Ma

Download Pdf Manuals

image

Related Search

Related Contents

Lynx - METTLER TOLEDO  HERMA Sea labels A4 Ø 40 mm round transparent extra strong adhesion film matt 600 pcs.  XDJ-R1 - Pioneer DJ  IB03-PCR-LA  MINI-COMPO CON REPRODUCTOR DE DVD ÍNDICE  est là ! - E  BACSYL PT SOLEIL 09-11  事故情報の分析に関する前回までの議論の整理 資料2−2  Partida Demorada depois da Partida Disparada  カシオ電卓取扱説明書  