        USER MANUAL AND INSTRUCTIONS
         Contents
1.   C  ANSI NFPA    Z223 1 National Fuel Gas Code    C  ANSI NFPA   Domestic Gas Conversion Burner  D  CAN CGA B 149 Installation Codes  E  ANSI ASME   CSD 1       The above codes are available from     National Fire Protection Association  NFPA  CSA International   Battery March Park 8501 E  Pleasant Valley Road  Quincy  Massachusetts  02269 Cleveland  OH 44134 5575  http   www nfpa org http   www csa international org  6 SAVIO FP USER MANUAL    1  General Information    The SAVIO FP is a high efficiency  non condensing  wall mounted gas boiler which pro   vides central heat  The boiler features a gas valve which modulates the energy input from  49 476BTU h to 122 837 BTU h  The boiler is shipped fully assembled  All units are pressure    and combustion tested at the factory prior to shipping     Key Features     e    Wall mountable   saving valuable floor  space    Several flue options available   Electronic spark ignition   Safety flow switch   positioned on the  main circuit  which monitors the flow and  protects the main heat exchanger from  thermal shock should there be a lack of  water in the system    Frost protection   contains an integral frost    Boiler operation recognition system    should the boiler not be used for longer  than 24 hours  it then performs a con   trolled system test to ensuring the motor   ized components within the boiler do not  become inoperable due to lack of use   Gas valve modulation   the gas input  modulates based off central heating tem   
2.  page 9  has  gone down   e It is necessary to fill up the appliance with water again  so as to raise the pressure to an  adequate level as described in the section 5 2 of this manual   If filling up with water has to be done very frequent  have the system checked for leaks     16 SAVIO FP USER MANUAL    6  Useful Advice Cont     If water comes out of the pressure relief valve pipe 3 in Fig  6 3     e Check on the temperature and pressure  gauge  figure 5 1 on page 11  that the  pressure in the central heating circuit is  not close to 3 bars  43 5 psi   In this case   temperature rise in the circuit can cause  the pressure relief valve to open    e So that this does not happen and to de   crease the pressure to a normal value  it  is advisable to vent some of the water in  the appliance through the bleed valves  present in the heating system        Figure 6 3    If water should occasionally leak from the boiler   e Close the cocks connected to the inlet gas pipe and to the supply cold water inlet pipe under  the boiler and call an Authorised Service Person     In case of problems other than those mentioned here  switch off the boiler  as described  in Section 5 5 on page 13 and call a competent and responsible service person     SAVIO FP USER MANUAL 17    Warranty  For SAVIO Residential  Wall Hung Gas Boilers    FIRST 2 YEARS WARRANTY FOR SAVIO SERIES  RESIDENTIAL HOT WATER BOILERS  BOYERTOWN  warrants that itswall hung boiler and casing are free  from defects in material and
3.  up  check that no air is present in it and E   0              that its valve is open    e Ifthe ambient temperature is too high  do  not alter the radiator valves  Reduce the JE  central heating temperature instead by    means of the room thermostat and the  knob  C in Fig  6 1               Figure 6 1    6 2 Frost Protection      The built in antifreeze system and any additional system protect the boiler from possible  damages due to the icing    e This system doesn   t guarantee the protection of the whole central heating system    e In the case that the external temperature may be lower than 32  F it is suggested to leave  the system running setting the room thermostat at a low temperature      When the boiler is completely switched off for a long period  it is recommended to empty  completely central heating circuit     6 3 Periodic Maintenance    e For efficient and continuous operation of the boiler  it is advisable to arrange maintenance  and cleaning by an Authorised Service Person  at least once a year    e During the service  the most important components of the boiler will be inspected and  cleaned  This service can be part of a maintenance contract    In particular  you are advised to have the following checks carried out    e primary heat exchanger      burner    e exhaust fume duct and flue    e pressurization of the expansion vessel    e filling up of the central heating circuit    e bleeding of air from the central heating system    e general check of the app
4.  workmanship for 2 years  from the date of installation  If any part on the boiler is  found to be defective within this period  BOYERTOWN  will replace the part free of charge     FIRST 10 YEARS WARRANTY FOR SAVIO SERIES  RESIDENTIAL HOT WATER BOILERS  SAVIO war   rants that the copper tube heat exchanger of the SAVIO  boilers are free from defects in material and workman   ship for 5 years from the date of installation  If the cop   per tube heat exchanger is found to be defective within  the first 5 years after installation  BOYERTOWN and  SAVIO will replace the copper tube heat exchanger     These warranties are subject to the condition that a  heating contractor whose principal occupation is the  sale and installation of heating equipment must have  installed the boiler  PARTS  WHICH ARE COVERED   consists of all materials supplied by SAVIO  identified  by BOYERTOWN   s part numbers in its literature  Other  parts supplied by the installer carry their own warranty  and each manufacturer has responsibility for its own  products     NOTE  ANY PART  WHICH IS REPLACED UNDER  WARRANTY  CARRIES ONLY THE UNEXPIRED  PORTION OF THE ORIGINAL WARRANTY     OWNER RESPONSIBILITIES    1  Provide for proper installation  which includes pres   sure relief and pressure reducing valves and high limit  safety controls on closed systems    2  Provide qualified periodic service to prolong proper  operation and service    3  Insure that boiler is installed in accordance with all  codes and ord
5. Savio FP    WALL HUNG GAS BOILER FOR  CENTRAL HEATING SUPPLY    Please Read Instructions Carefully  Save for Future Reference    WARNING  If the information in this manual is not followed  exactly  a fire or explosion may result causing property dam   age  personal injury or loss of life         Donotstore or use gasoline or other flammable vapors and liquids  in the vicinity of this or any other appliance         WHAT TO DO IF YOU SMELL GAS  Do not try to light any appliance   Do not touch any electric switch  do not use any phone in your  building   Immediately call your gas supplier from a neighbor   s phone  Fol   low the gas supplier   s instructions   If you can not reach your gas supplier call the fire department         Installation and service must be performed by a qualified installer   service agency or the gas supplier           Manufactured by  Distributed by  ES Bovertown Furnace  Caldaie a Gas BOYERTOWN FURNACE CO   PO Box 100    T  Z  O       O      cc  l   0     Q  Z   lt   mua    lt      Z   lt      cr  Lu  0   gt     PEN  AS BOYERTOWN PA 19512  SA  9 4    Y      1 610 369 1450    j    c us Ei NEHA SAVIO FP USER MANUAL       Dear Customer   Thank you for buying a SAVIO FP Boiler System     The SAVIO FP is a high efficiency  non condensing  wall mounted gas boiler which  provides central heat and domestic hot water     We realize that it is not possible to answer all questions about the SAVIO boiler system in this  manual  Reading this installation manual doe
6. an air and thus may travel throughout the  building     BRIEF EXPOSURE TO HIGH CONCENTRATIONS OF CO  OR  PROLONGED EXPOSURE TO LESSER AMOUNTS OF CO MAY  RESULT IN CARBON MONOXIDE POISONING  EXPOSURE CAN BE  FATAL AND EXPOSURE TO HIGH CONCENTRATIONS MAY RESULT  IN THE SUDDEN ONSET OF SYMPTOMS INCLUDING UNCONSCIOUSNESS     Symptoms of CO poisoning include the following     The symptoms of CO poisoning are often confused with those of influenza  and the highest  incidence of poisoning occurs at the onset of cold weather or during flu season    A victim may not experience any symptoms  only one symptom  or a few symptoms   Suspect the presence of carbon monoxide if symptoms tend to disappear when you  leave your home     The following signs may indicate the presence of carbon monoxide     Hot gasses from appliance  venting system pipes or chimney  escaping into the living  space    Flames coming out around the appliance    Yellow colored flames in the appliance    Stale or smelly air    The presence of soot or carbon in or around the appliance    Very high unexplained humidity inside the building     If any of the symptoms of CO occur  or if any of the signs of carbon monoxide are present   VACATE THE PREMISES IMMEDIATELY AND CONTACT A QUALIFIED HEATING SER   VICE COMPANY OR THE GAS COMPANY OR THE FIRE DEPARTMENT     ONLY QUALIFIED  LICENSED SERVICE CONTRACTORS SHOULD PERFORM WORK  ON YOUR SAVIO FP        SAVIO FP USER MANUAL 5    IMPORTANT INFORMATION  Please read this page care
7. causing property dam   age  personal injury or loss of life         Donot store or use gasoline or other flammable vapors and liquids in the  vicinity of this or any other appliance         WHAT TO DO IF YOU SMELL GAS  Do not try to light any appliance   Do not touch any electric switch  do not use any phone in your build   ing   Immediately call your gas supplier from a neighbor   s phone  Follow the  gas supplier   s instructions   If you can not reach your gas supplier call the fire department         Installation and service must be performed by a qualified installer  ser   vice agency or the gas supplier     DANGER    Caution  Do not store or use flammable materials  chemicals or flammable liquids   especially gasoline  in the vicinity of this heating appliance     Caution  Should overheating occur or the gas supply fail to shut off  do not turn  off or disconnect the electrical supply to the pump  Instead  shut off the gas  supply at a location external to the appliance     Caution  Do not use this boiler if any part has been under water  Immediately  call a qualified service technician to inspect the boiler and to replace any part of  the control system and any gas control which has been under water        SAVIO FP USER MANUAL    WARNING    Any appliance that burns natural gas  propane gas  fuel oil  wood or coal is capable of pro   ducing carbon monoxide  CO   Carbon Monoxide  CO  is a gas which is odorless  colorless  and tasteless but is very toxic  CO is lighter th
8. ed in cold weather  with consequent risk of freezing  do not switch off the boiler at the circuit breaker or close the gas inlet cock    e When you expect not to use the boiler for a long period follow the instructions given in sec   tion 5 6 on page 14     5 2 Refilling procedure   e Isolate the boiler from the electrical sup   ply at the circuit breaker     The boiler should have been installed with  an automatic fill valve  external to the unit   Open the cold water supply to the auto   matic fill valve   e The pressure should be 1     1 5 bar  14 5      22 psi    e The automatic fill valve should maintain Figure 5 1  this pressure  but not exceed it        Air introduced into the boiler during this filling process will vent through the automatic air purger  fitted to the boiler  You may also find it necessary to vent air from your heating circuit using the  installed vents  however be aware that excessive venting will cause the pressure in the system  to drop  Always ensure that the pressure gauge is set at the required pressure     SAVIO FP USER MANUAL 11    5  Instructions For Use Cont     5 3 Lighting Operating Instructions   Warnings  Do not attempt to start the boiler unless all cleanout doors are secured and    sealed  Do not attempt to light the burner by hand     1    Check that the cocks connected to the  gas inlet pipe and to the supply cold wa   ter inlet pipe  see section 3 3 for pipes   are open    Turn on the electricity supply to the boiler   switching on t
9. fully     ALL BOILERS MUST BE INSTALLED IN ACCORDANCE WITH NATIONAL   STATE AND LOCAL PLUMBING  HEATING AND ELECTRICAL CODES  AND ORDINANCES  AS WELL AS THE REGULATIONS OF THE SERVING  ELECTRICAL  WATER AND GAS UTILITIES     All systems should be designed by competent contractors  and only persons  knowledgeable in the layout and installation of heating systems should attempt  the installation of any boiler  It is the responsibility of the installing contractor  to see that all controls are correctly installed and operating properly when the  installation is completed     This boiler is intended for use  only with propane or natural gas  All flammable  liquids  especially gasoline   chemicals  rags  paper  wood scraps  debris  etc    should be kept away from the boiler at all times  Keep the boiler area clean and  free of all fire hazards     Please read the literature and warranties supplied by the manufacturers of the  various accessory equipment  This equipment is warranted by the respective  manufacturers  not by BOYERTOWN  Each piece of equipment must be  installed and used according to the recommendations of the manufacturer     Codes and Regulations     Installation of the boiler and related equipment must conform to national  state and  local regulating agencies and codes applicable to the installation of the equipment  In  the absence of local requirements  the following codes apply     A  ANSI NFPA    70 National Electric Code  B  ANSI NFPA    211 Chimneys and Vents
10. he circuit breaker  The appli   ance operation light A  figure 5 2  will flash  every 4 seconds  stand by condition            TLS  no      Figure 5 2    3    If the boiler is to be used for c h position  the function selector C as in figure 5 2   The appliance operation light A will flash  every 2 seconds  operating boiler     If the appliance will not operate  follow  the extinguishing instructions on page 13  and call your service technician or gas  supplier     5 4 Central Heating Circuit Temperature        The output temperature of c h  water is  adjustable from a minimum of about 100    F to amaximum of about 176   F  Figure  5 3   by turning the knob B   Adjustment of the boiler temperature al   ters the gas flow at the burner according  to the thermal demand in the system  So  it is usual to see the burner lit at the mini   mum level for more or less long periods   Adjustment of central heating  output on  the boiler is automatic  The greatest out   put is factory pre set  however  it can be  reduced according to actual system re   quirements  These adjustments must be  carried out by a qualified person  there   fore we advise you to contact your install   er or Service Agent     12 SAVIO FP USER MANUAL                      Figure 5 3    5  Instructions For Use Cont     Adjustment   e In order to achieve optimal settings for e The temperature and pressure gauge  Fig     economy and comfort  we recommend 5 1 on page 11  will allow you to check  adjusting the operating 
11. ig  5 6       Minimum                Maximum       Figure 5 7       Figure 5 6    Adjustment of the d h w  temperature is completely separate from that of the c h  circuit    The adjustment system integrated within the boiler automatically controls the flow of gas to  the burner in order to keep the temperature of d h w  delivered constant  between the limits of  maximum and minimum output    Where the demand is at a low level or with the temperature set to the minimum it is normal to  see a cycle of lighting and extinguishing of the burner when running    Regulate the domestic hot water temperature to a value suitable for your requirements   Reduce the need to mix the hot water with cold water    In this way  you will appreciate the characteristics of automatic regulation    If the water is particularly hard  we recommend regulating the boiler at a temperature lower  than 120   F fig    In these cases  we nevertheless recommend the installation of a water softener on the domes   tic hot water system    If the maximum flow rate of the domestic hot water is too high for a sufficient temperature to be  reached  it is advisable to have a suitable flow rate limiter installed by an Authorised Assistance  Technician     14 SAVIO FP USER MANUAL    6  Useful Advice    6 1 Central Heating   e For reasonably economical service install C  a room thermostat   e Never shut off the radiator in the area  where the room thermostat is installed   e Ifa radiator  or a convector  does not heat 
12. inances    4  This warranty does not apply to boilers  which are  subject to misuse  abuse  neglect  alteration  accident   excessive temperature  excessive pressure  or corro   sive water or atmosphere    5  Owner will be responsible for return of faulty compo   nents to BOYERTOWN  PA  freight pre paid     BOYERTOWN and SAVIO will not be responsible for   1  Components that are part of the heating system  but  were not manufactured by SAVIO or BOYERTOWN as  part of the boiler    2  The workmanship of the installers of SAVIO boilers   Furthermore  this warranty does not assume any liabil   ity for unsatisfactory performance caused by improper  installation    3  Any costs for labor to remove or replace the faulty  component    4  Improper boiler application or adjustments  control  settings  care or maintenance    5  Any damage associated with corrosion or leakage  due to the use of    non barrier     plastic pipe in the heat   ing system      IMPLIED WARRANTIES OF FITNESS FOR A PAR   TICULAR PURPOSE AND MERCHANTABILITY  SHALL BE LIMITED TO THE DURATION OF THE  EXPRESSED WARRANTY  SAVIO AND BOYER   TOWN EXPRESSLY DISCLAIM AND EXCLUDE ANY  LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL  DAMAGES FOR BREACH OF ANY EXPRESSED OR  IMPLIED WARRANTY     THIS WARRANTY GIVES YOU SPECIFIC LEGAL  RIGHTS  AND YOU MAY HAVE OTHER RIGHTS  THAT VARY FROM STATE TO STATE     For prompt warranty service  notify the installer  who   in turn  will notify the distributor from whom the boiler  was purcha
13. is SAVIO boiler has a 2 year warranty on the boiler  and 10 years on the heat exchanger  a   copy of which is provided with the boiler  Please be sure to return the warranty registration card   as the warranty will be void without your boiler   s serial numbers  located on the ratings label  affixed to the boiler   date of installation and the name of your installer being on record in our files     Thank you for purchasing our SAVIO FP boiler  If you have questions or comments   please don t hesitate to contact us immediately  Our goal is 100  customer satisfaction     BOYERTOWN    2 SAVIO FP USER MANUAL    Table of Contents       Section Title Section Number Page Number  Warnings   4 5  Important Information   6  General Information 1 7  Technical Information 2 7 8  Appliance Description 3 9  Operation Lights 4 10  Instructions for Use 5 11 14   Warnings 5 1 11  Refilling Procedure 5 2 11  Lighting Operation Instruction 9 3 12  Central Heating Circuit Temp  5 4 12 13  Extinguishing Instructions 5 5 13  Domestic hot water 5 6 14  Useful Advice 6 15 17  Central Heating 6 1 15  Frost Protection 6 2 15  Periodic Maintenance 6 3 15  External Cleaning 6 4 16  Operational Faults 6 5 16 17  Warranty 18    SAVIO FP USER MANUAL 3    WARNING    Boiler is certified as an indoor appliance  Do not install boiler outdoors or locate where it will  be exposed to freezing temperatures     4    WARNING  If the information in this manual is not followed  exactly  a fire or explosion may result 
14. liance   s operation     SAVIO FP USER MANUAL 15    6  Useful Advice Cont     6 4 External Cleaning   e Before performing any cleaning  disconnect the appliance from the electrical mains  using    the dedicated circuit breaker or serviceman   s switch located adjacent to the appliance    e To clean the external panels  use a cloth soaked in soapy water  Do not use solvents  abra   sive powders or sponges      Do not carry out cleaning of the appliance and or its parts with readily flammable substanc   es  for example petrol  alcohols  naphtha  etc       6 5 Operational Faults   If the lock out signal lamp comes on     e This indicates that the safety lock out 1 A C   Fig  6 2  has stopped the boiler   e To re start the boiler  it is necessary to  turn the function selector B in the position   2  and then press the boiler reset button  2  Fig  6 2     e For the first light up and following main   tenance procedures for the gas supply  it  may be necessary to repeat the resetting Figure 6 2  operation several times so as to remove  the air present in the pipework           If noises due to air bubbles are heard during operation   e You should check that the pressure on the temperature and pressure gauge  Fig  5 1 on  page 11  is not below the correct setting   e If required  fill up the system correctly  as described in the section 5 2 of this manual   e Bleed any air present in the radiators  if necessary     If the pressure on the temperature and pressure gauge  Figure 5 1 on
15. op 3   im _  8    Sides in   2     Bottom in   8     Flue pipe free air   in   0      FLUE GAS FIGURES    DOMESTIC HOT WATER     Menmu presne   psi   15    Minimum pressure   psi   235         3  Appliance Description    3 1 Overview     1 Case front panel  2 Control panel  3 Control panel cover    3 2 Control Panel     4 Central heating circuit temperature and   pressure gauge   Lock out signal lamp   Boiler reset button   Function selector knob and radiator   temperature control   8 Domestic hot water  temperature  control knob   9 Appliance operation lights          NOOO                          gt  po E 5 r    yi  gt         NA  LY 69 ee  AR      owy eA a op              9 8 7 6 5  Figure 3 2  3 3 Piping Connections    a ny  Gas inlet pipe e      i       Main circuit drain cock   C h  supply copper pipe   C h  return copper pipe   C h PRV discharge copper pipe  D h w  hot water outlet   D h w  cold water inlet    llill  Ill    QO7m7mMvgagW gt y gt     E C F A G D B  Figure 3 3  SAVIO FP USER MANUAL 9    4  Operation Lights    Three lights  8 in Fig  3 2  give detailed indication regarding the operation of the boiler   The following table gives the relationship between each of the possible light combinations and  their meaning     Ashort pulse every 4 seconds  stand by condition Function  selector in  2  position  Anti freeze system active    1 second pulse every 2 seconds  normally operating boiler   Function selector in on position   Central heating operation   Frost pro
16. perature to within   2   F   Diagnostic information system equipped    with three LED diagnostic lights for quick  error assessment     protection system to prevent frost dam   age which can occur in areas susceptible  to very cold weather conditions     2  Technical Information  M130 30CM     GENERAL    INJ ECTORS No  Size  4    Poon   a  o    CENTRAL HEATING    Maximum pressure  psi  200    Minimum pressure   psif 435    Max nead oss  at 44 GPM    A   99      ELECTRICAL  Frequency   Hz   60            SAVIO FP USER MANUAL 7    2  Technical Information Cont     ENERGY CAPACITY   Nominal heat input    0 2000ft   MBH   1228  Nominal heat input    2000 4500ft  CECA mO   Minimum heat input    Maximum useful output    0 2000ft  jf er 10057  Maximum useful output    2000 4500ft      Minimum useful output   useful  Minimum useful output     37 0      GAS SUPPLY PRESSURE     cas   Nomai  Min   Max    Propane   inwe   7 0   80   190     GAS PRESSURE AT BURNER    Gas  f min   Max   lation    Natural  mue  08   53   24    Propane   inwe   14   90   52      FLUE DESIGN    Minimum Venturi pressure   inwc me  288      Flue pipe diameter   pipe   Flue pipe diameter          25 4  Coaxial 3 25 5  Twin split pipes        3 25 3 25  Nominal heat flow rate   0 2000ft  leet  Nominal heat flow rate   2000 4500ft  Moe  Min Exhaust temperature  Max Exhaust temperature    8 SAVIO FP USER MANUAL    GAS FLOW RATE  ces    mn   Max      CLEARANCE TO COMBUSTIBLES     Front    in   18    Bak in    0    T
17. s not make the reader an expert in all aspects  of installation and operation  and does not replace the need for a qualified  licensed heating  contractor  We urge you to contact your installing contractor or distributor if you are in question  about any aspect of your boiler   s performance  Our main concern is that you are satisfied with  your boiler and its performance  We require that your contractor complete efficiency tests using  instruments     The external controls and accessories listed in this manual  excluding those supplied inside  the boiler  are intended to serve as guidelines rather than specific recommendations  We re   alize that other makes and models of such devices are available and can be used as suc   cessfully as those we specify  The installing contractor is the best judge of a system   s specific  requirements  as well as the local availability of certain makes and models of controls and  accessories  The preceding does not apply  however  to the equipment that comes with every  boiler  such as the overheat control and pressure relief valves  The installation of the spe   cific devices supplied with every boiler is absolutely necessary to the safe operation of  the boiler and protection of the heating system     All SAVIO wall hung boilers are built in accordance with the ASME boiler and pressure vessel  code  and bear the    H    stamp  The Entire range of applications for the SAVIO FP has been  tested to standard CSA 4 9 and is CSA compliant     Th
18. sed  If this does not result in corrective ac   tion  contact SAVIO through BOYERTOWN Hydronic  Technologies  Address Below  with details in support  of the warranty claim  All claims must be processed  through proper trade channels  Contact with SAVIO di   rectly is not recommended for rapid claim settlement     BOYERTOWN Furnace Co   PO Box 100  Boyertown PA 19512  1 610 369 1450  www boyertownfurnace com    SAVIO BOILER WARRANTY REGISTRATION  IMPORTANT   Registration required  To gain complete warranty  Protection  fill in and mail this card  within 1 year of installation to the address listed below                            NAME  ADDRESS    CITY  STATE  ZIP    BOILER SERIAL NO   DATE OF INSTALL   NAME OF INSTALL CO   ADDRESS    CITY  STATE  ZIP           RETURN TO  BOYERTOWN FURNACE Co  PO Box 100 BOYERTOWN PA 19512 1 610 369 1450    18 SAVIO FP USER MANUAL    SAVIO FP USER MANUAL    19    17962 1512 0 2908  20A4  ma    N  LOIL     
19. tect operation   Faulty central heating temperature probe NTC   Faulty primary circuit  no water or absence of flow     Lack of burner ignition  no ignition signal from the full se     Ignition gas pressure adjustment  Minimum gas pressure adjustment    Flashing lamp  alone   Flashing lamp  al   Lamp OFF or simultaneously ternate with another  with another lamp  lamp       10 SAVIO FP USER MANUAL    5  Instructions For Use    5 1 Warnings     In order to guarantee safety and correct operation  it is essential that all the tests are carried    out by a competent and responsible licensed service person before lighting up the boiler    e The tests are described in the installation  operation and service instructions manual in Sec   tion 15 Commissioning      Ensure that the Central Heating circuit is regularly filled with water checking that the pres   sure indicated on the temperature and pressure gauge  4 on figure 3 2  is not lower than 1  bar  14 5 psi  as shown on figure 5 1    e Ifthe pressure reading on the pressure gauge is below 1 bar  14 5 psi   then the system  will require filling  An automatic filling valve is normally provided by the installer for this pur   pose       If you are in any doubt regarding this procedure you are advised to contact your In   staller or an Approved Service Person    e This appliance is provided with a built in anti freeze system that operates the boiler when  the temperature is below 41   F   e Therefore  when the boiler is not lit or us
20. temperature of that the set temperature is obtained   the central heating water according to the From 41 to 59  F Between 23 and 41  F    outside temperature  positioning the knob  as in figure 5 4   e Your installer may have installed addi   tional energy saving equipment and will  be able to recommend the most suitable  adjustment for your system           Lower than 23  F    Figure 5 4  5 5 Extinguishing Instructions     To turn the boiler off set the function se  A E    lector C to the position shown in the Fig   ure 5 5    e The appliance operation light A  figure5 2   will flash every 4 seconds  stand by  mode     e Turn off electric power to the appliance  at the circuit panel of boiler serviceman s  switch                       Figure 5 5    When you expect not to use the boiler for a long period   e Switch off the electricity supply to the boiler  by means of the circuit breaker     Shut off the gas supply cock connected to the gas inlet pipe and the cock connected to the  supply cold water inlet pipe  see section 3 3 for pipes   e Empty the water circuit  if necessary  as shown in the installation  operation and service  instructions manual in the maintenance section        SAVIO FP USER MANUAL 13    5  Instructions For Use Cont     5 6 Domestic hot water temperature   The temperature of the domestic hot water coming out from the boiler can be regulated from a    minimum of approximately 95   F to a maximum of approximately 131   F by turning the control  shown in f
    