1. FRONT PANEL 10 100 1000Base T LNK ACT SPD 1000 LK ORO act LK act SOR O acT AAD lt P L003GX2CP From Top to Bottom Green LED lights when Power is connected LNK ACT Link Activity LED SPD1000 1000 Speed LED LEDs The table below describes the operating modes Power is Applied OFF Power is OFF OFF N B LNK ACT No link activity on cable SPD1000 Link is 1OOOMbps Revised 8 5 2009 APPLYING POWER Top View CHASSIS GROUND V Negative GND Return V Positive 10 30VDC Vi Negative GND Return V Positive 10 30VDC DETAIL Unscrew amp Remove the DC Voltage Input Plug from the top header Install the DC Power Cables into the Plug observing polarity on unit Plug the Voltage Input Plug back into the top header Tightening torque for the terminal block power plug is 0 5 Nm 0 368 Pound Foot All LEDs will flash ON Momentarily Verify the Power LED stays ON GREEN Note Either V or V2 can be connected to power for minimal operation For redundant power operation V and V2 plugs must be connected to separate DC Voltage sources Use wire sizes of 16 28 gauge The power cord should be limited to less than 10 meters in order to ensure optimum performance Recommended 24V DC Power Supplies similar to 100 240VAC N Tron NTPS 24 1 3 DC 24V 1 3A NOTE Not appropriate for use with M12 POE and HV models Revised 8 5 2009 N TRON SWITCH
2. a drain wire to earth ground from one of the V terminal plugs as DRAIN WIRE WITH shown here will ground the switch and the chassis The power leads LUG CONNECTING from the power source should be limited to 3 meters or less in length SWITCH CHASSIS TO KNOWN GOOD GROUNDING POINT Note Before applying power to the grounded switch you must use a volt meter to verify there is no voltage difference between the power supply s negative output terminal and the switch chassis grounding point If the use of shielded cables is required it is generally recommended to only connect the shield at one end to prevent ground loops and interfere with low level signals i e thermocouples RTD etc Cat5e cables manufactured to EIJA 568A or 568B specifications are required for use with N Tron Switches METALLIC NONMETALLIC SHIELDED PATCH CABLE STP oo gt Er STP Sr aea I m a a Mi a Hi gt 1 Note Strain relief boots not shown for clarity purposes In the event all Cat5e patch cable distances are small i e All Ethernet devices are located the same local cabinet and or referenced to the same earth ground it is permissible to use fully shielded cables terminated to chassis ground at both ends in systems void of low level analog signals Revised 8 5 2009 10 CONNECTING THE UNIT For 10Base T ports plug a Category 3 or greater twisted pair cable into the RJ45 connector For 100 1000Base T ports plug a Category 5e or grea
3. IEEE compliant LC duplex connectors for fiber optic communications in a convenient SFP modular design All 10 100 1000Base T ports utilize the RJ45 shielded connectors The 1002MC MCE is a two port unmanaged media converter that converts 10 100 1000Base T copper to 1000BaseSX LX full duplex fiber The 1003GX2 GXE2 is a three port unmanaged switch that offers one 10 100 1000Base T copper port and two 1000BaseT S X LX full duplex copper fiber ports The 1005TX is a five port unmanaged switch that offers five 10 100 1000Base T copper ports Key Features e Compact Space Saving Package e Full IEEE 802 3 Compliance e Unmanaged Operation e Extended Environmental Specifications 40 C to 85 C Operating and Storage Temperature Supports Full Half Duplex Operation Up to 10 0 Gb s Maximum Throughput MDIX Auto Sensing Cable Auto Sensing Speed and Flow Control Full Wire Speed Communication Store and forward Technology Redundant Power Inputs 10 30 VDC LED Link Activity Status Indication Hardened Metal Enclosure Industry Standard 35mm DIN Rail Mounted Enclosure Revised 8 5 2009 PACKAGE CONTENTS Please make sure the package contains the following items 1 1000 Series Media Converter or Ethernet Switch 2 Product CD Contact your carrier if any items are damaged UNPACKING Remove all the equipment from the packaging and store the packaging in a safe place File any damage claims with the carrier CLEANING Clean only with a damp
4. not operate as warranted during the applicable warranty period N TRON shall at its option and expense repair the defective product or part deliver to customer an equivalent product or part to replace the defective item or refund to customer the purchase price paid for the defective product All products that are replaced will become the property of N TRON Replacement products may be new or reconditioned Any replaced or repaired product or part has a ninety 90 day warranty or the remainder of the initial warranty period whichever is longer N TRON shall not be responsible for any custom software or firmware configuration information or memory data of customer contained in stored on or integrated with any products returned to N TRON pursuant to any warranty OBTAINING WARRANTY SERVICE Customer must contact N TRON within the applicable warranty period to obtain warranty service authorization Dated proof of purchase from N TRON or its authorized reseller may be required Products returned to N TRON must be pre authorized by N TRON with a Return Material Authorization RMA number marked on the outside of the package and sent prepaid and packaged appropriately for safe shipment Responsibility for loss or damage does not transfer to N TRON until the returned item is received by N TRON The repaired or replaced item will be shipped to the customer at N TRON s expense not later than thirty 30 days after N TRON receives the product N TRON shall
5. GROUNDING TECHNIQUES FOR 1000 SERIES The grounding philosophy of any control system is an integral part of the design N Tron switches are designed to be grounded but the user has been given the flexibility to float the switch when required The best noise immunity and emissions i e CE are obtained when the N Tron switch chassis is connected to earth ground via a drain wire Some N Tron switches have metal din rail brackets that can ground the switch if the din rail is grounded In some cases N Tron switches with metal brackets can be supplied with optional plastic brackets if isolation is required Users may run a drain wire amp lug from the screw provided on the back face of the enclosure In the event the provided grounding screw has been lost care should be taken to limit the penetration of the outer skin by less than 1 4 Failure to do SO may cause irreversible damage to the internal components of the switch Note Ensure the power supply is grounded properly before applying power to the grounded switch This may be verified by using a voltmeter to determine that there is no voltage difference between the power supply s negative output terminal and the chassis grounding point of the switch DRAIN WIRE WITH LUG CONNECTING SWITCH CHASSIS TO KNOWN GOOD GROUNDING POINT METALLIC DIN RAIL CLIP As an alternative grounding method both V legs of the power input connector are connected to chassis internally on the PCB Connecting
6. IN TRON DUSTRIAL NETWORK COMPANY 1000 Series Gigabit Media Converter amp Industrial Gigabit Ethernet Switch User Manual amp Installation Guide Revised 8 5 2009 IN TRON THE INDUSTRIAL NETWORK COMPANY Industrial Gigabit Ethernet Switch Installation Guide 1002MC SX 1000BaseSX multimode fiber media converter 1002MC LX YY 1000BaseLX singlemode fiber media converter 1003GX2 SX 1000BaseSX multimode fiber switch 1003GX2 LX YY 1000BaseLX singlemode fiber switch 1003GX2 B Custom mix and match 1003GX2 switch 1005TX 5 port gigabit Ethernet switch Where YY is 10 for 10km max fiber segment length 40 for 40km max fiber segment length 70 for 70km max fiber segment length 1003GX2 B SFP Mini GBIC Fiber Transceivers NTSFP SX LC Style Connector up to 550m NTSFP LX 10 LC Style Connector up to 10km NTSFP LX 40 LC Style Connector up to 40km NTSFP LX 70 LC Style Connector up to 70km Revised 8 5 2009 Copyright N TRON Corp 2008 820 S University Blvd Suite 4E Mobile AL USA 36609 All rights reserved Reproduction adaptation or translation without prior written permission from N TRON Corp is prohibited except as allowed under copyright laws Ethernet is a registered trademark of Xerox Corporation All other product names company names logos or other designations mentioned herein are trademarks of their respective owners The information contained in this document is subject to change wi
7. OR AUTHORIZES ANY OTHER PERSON TO ASSUME FOR IT ANY OTHER LIABILITY IN CONNECTION WITH THE SALE INSTALLATION MAINTENANCE OR USE OF ITS PRODUCTS N TRON SHALL NOT BE LIABLE UNDER THIS WARRANTY IF ITS TESTING AND EXAMINATION DISCLOSE THAT THE ALLEGED DEFECT OR MALFUNCTION IN THE PRODUCT DOES NOT EXIST OR WAS CAUSED BY CUSTOMER S OR ANY THIRD PERSON S MISUSE NEGLECT IMPROPER INSTALLATION OR TESTING UNAUTHORIZED ATTEMPTS TO OPEN REPAIR OR MODIFY THE PRODUCT OR ANY OTHER CAUSE BEYOND THE RANGE OF THE INTENDED USE OR BY ACCIDENT FIRE LIGHTNING POWER CUTS OR OUTAGES OTHER HAZARDS OR ACTS OF GOD LIMITATION OF LIABILITY TO THE FULL EXTENT ALLOWED BY LAW N TRON ALSO EXCLUDES FOR ITSELF AND ITS SUPPLIERS ANY LIABILITY WHETHER BASED IN CONTRACT OR TORT INCLUDING NEGLIGENCE FOR INCIDENTAL CONSEQUENTIAL INDIRECT SPECIAL OR PUNITIVE DAMAGES OF ANY KIND OR FOR LOSS OF REVENUE OR PROFITS LOSS OF BUSINESS LOSS OF INFORMATION OR DATA OR OTHER FINANCIAL LOSS ARISING OUT OF OR IN CONNECTION WITH THE SALE INSTALLATION MAINTENANCE USE PERFORMANCE FAILURE OR INTERRUPTION OF ITS PRODUCTS EVEN IF N TRON OR ITS AUTHORIZED RESELLER HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES AND LIMITS ITS LIABILITY TO REPAIR REPLACEMENT OR REFUND OF THE PURCHASE PRICE PAID AT N TRON S OPTION THIS DISCLAIMER OF LIABILITY FOR DAMAGES WILL NOT BE AFFECTED IF ANY REMEDY PROVIDED HEREIN SHALL FAIL OF ITS ESSENTIAL PURPOSE DISCLAIMER Some countries stat
8. cloth INSTALLATION Read the following warning before beginning the installation WARNING A Never install or work on electrical equipment or cabling during periods of lightning activity Never connect or disconnect power when hazardous gasses are present Revised 8 5 2009 DIN Rail Mounting Install the unit in a standard DIN rail Recess the unit to allow at least 2 of horizontal clearance for CATSe cable bend radius or 5 of horizontal clearance for Fiber Optic cable bend radius To install the unit to 35mm industrial DIN rail place the top edge of the included mounting bracket on the back of the unit against the DIN rail at a 15 angle as shown Rotate the bottom of the unit to the back away from you until it snaps into place To remove the unit from the 35mm industrial DIN rail pull forward on the unit until it disengages from the bottom of the DIN rail Rotate the bottom of the unit towards you and up at an approximate 15 upward angle to completely remove the unit URMK Most N Tron products are designed to be mounted on industry standard 35mm DIN rail However DIN rail mounting may not be suitable for all applications Our Universal Rack Mount Kit P N URMK may be used to mount the 1000 Series enclosures to standard 19 racks and our Panel Mount Assembly P N 1000 PM may 1000 PM be used to mount the 1000 Series enclosures to a panel or any other flat surface Revised 8 5 2009
9. dential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications Operation of this device in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense INDUSTRY CANADA This Class A digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations Operation is subject to the following two conditions 1 this device digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Cet appareillage num rique de la classe A r pond a toutes les exigences de l interf rence canadienne causant des r glements d quipement L op ration est sujette aux deux conditions suivantes 1 ce dispositif peut ne pas causer l interf rence nocive et 2 ce dispositif doit accepter n importe quelle interf rence re ue y compris l interf rence qui peut causer l op ration peu d sir e Revised 8 5 2009 12 1002MC KEY SPECIFICATIONS Physical Height Width Depth w typical SFP installed Weight DIN Rail Electrical Inp
10. es or provinces do not allow the exclusion or limitation of implied warranties or the limitation of incidental or consequential damages for certain products supplied to consumers or the limitation of liability for personal injury so the above limitations and exclusions may be limited in their application to you When the implied warranties are not allowed to be excluded in their entirety they will be limited to the duration of the applicable written warranty This warranty gives you specific legal rights which may vary depending on local law GOVERNING LAW This Limited Warranty shall be governed by the laws of the State of Alabama U S A Revised 8 5 2009
11. not be responsible for any software firmware information or memory date of customer contained in stored on or integrated with any products returned to N TRON for repair whether under warranty or not ADVANCE REPLACEMENT OPTION Upon registration this product qualifies for advance replacement A replacement product will be shipped within three 3 days after verification by N TRON that the product is considered defective The shipment of advance replacement products is subject to local legal requirements and may not be available in all locations When an advance replacement is provided and customer fails to return the original product to N TRON within fifteen 15 days after shipment of the replacement N TRON will charge customer for the replacement product at list price WARRANTIES EXCLUSIVE IF AN N TRON PRODUCT DOES NOT OPERATE AS WARRANTED ABOVE CUSTOMER S SOLE REMEDY FOR BREACH OF THAT WARRANTY SHALL BE REPAIR REPLACEMENT OR REFUND OF THE PURCHASE PRICE PAID AT N TRON S OPTION TO THE FULL EXTENT ALLOWED BY LAW THE FOREGOING WARRANTIES AND REMEDIES ARE EXCLUSIVE AND ARE IN LIEU OF ALL OTHER WARRANTIES TERMS OR CONDITIONS EXPRESS OR IMPLIED EITHER IN FACT OR BY OPERATION OF LAW STATUTORY OR OTHERWISE INCLUDING WARRANTIES TERMS OR CONDITIONS OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE SATISFACTORY QUALITY CORRESPONDENCE WITH DESCRIPTION AND NON INFRINGEMENT ALL OF WHICH ARE EXPRESSLY DISCLAIMED N TRON NEITHER ASSUMES N
12. nput Voltage Input Current Inrush Current Input Ripple Input Wire Size Environmental Operating Temperature Storage Temperature Operating Humidity Operating Altitude Network Media 10BaseT 100BaseT 1000BaseT 1000BaseSX Multimode 1000BaseLX Singlemode Connectors 10 100 1000BaseTX 1000Base X SFP 4 0 10 16 cm 1 0 2 54 cm 3 61 9 165 cm 0 7 Ibs 0 32 kg 35 mm 10 30 VDC Regulated 200mA max 24VDC Steady State 13 Amp 0 8 ms max 24VDC Less than 100 mV 16 28 AWG 40 C to 85 C 40 C to 85 C 10 to 90 Non Condensing O to 10 000 ft gt Cat 3 gt Cat 5 gt Cat Se 50 62 5 125um 7 10 125um One 1 RJ45 TX Copper Port Up to two 2 SFP LC Duplex Gigabit Fiber Ports Recommended Minimum Wiring Clearance Front 5 12 70 cm Top 1 2 54 cm Revised 8 5 2009 Regulatory Approvals Safety UL Listed per ANSI ISA 12 12 01 2000 US and Canada and listed for use in Class I Div 2 Groups A B C D T4 EMI EN61000 6 4 EN55011 Class A FCC Title 47 Part 15 Subpart B Class A ICES 003 Class A EMS EN61000 6 2 EN61000 4 2 ESD EN61000 4 3 RS EN61000 4 4 EFT EN61000 4 5 Surge EN61000 4 6 Conducted Disturbances Warranty 3 year from the date of purchase u A FC C E LISTED K 65SN Revised 8 5 2009 16 1005TX KEY SPECIFICATIONS Physical Height Width Depth Weight DIN Rail Electrical Input Voltage Inp
13. ter twisted pair cable into the RJ45 connector Connect the other end to the far end station Verify that the LNK LEDs are ON once the connection has been completed To connect any other port to another Switch or Repeater use a standard CatSe straight through or crossover cable Warning Creating a port to port connection on the same switch i e loop is an illegal operation and will create a broadcast storm which will crash the network TROUBLESHOOTING 1 Make sure the Power LED is ON 2 Make sure you are supplying sufficient current for the version chosen Note The inrush current will exceed the steady state current by 2X 3 Verify that Link LEDs are ON for both ports 4 Verify cabling used between stations 5 Verify that cabling is Category 3 or greater for 10Mbit Operation SUPPORT Tel 251 342 2164 FAX 251 342 6353 http www n tron com N TRON_ Support n tron com Revised 8 5 2009 11 FCC STATEMENT This product complies with Part 15 of the FCC A Rules Operation is subject to the following conditions 1 This device may not cause harmful Interference 2 This device must accept any interference received including interference that may cause undesired operation NOTE This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a resi
14. thout notice N TRON Corp makes no warranty of any kind with regard to this material including but not limited to the implied warranties of merchantability or fitness for a particular purpose In no event shall N TRON Corp be liable for any incidental special indirect or consequential damages whatsoever included but not limited to lost profits arising out of errors or omissions in this manual or the information contained herein Contact Information N TRON Corp 820 South University Blvd Suite 4E Mobile AL 36609 TEL 251 342 2164 FAX 251 342 6353 Website www n tron com Email N TRON_ Support n tron com Revised 8 5 2009 ELECTRICAL SAFETY WARNINGS AX A This equipment is suitable for use in Class I Division 2 Groups A B C and D or non hazardous locations only WARNING Explosion Hazard Substitution of components may impair suitability for Class I Division 2 WARNING Explosion Hazard Do not disconnect while circuit is live unless area is known to be non hazardous WARNING Explosion Hazard Do not replace the device unless power has been switched off or the area is known to be non hazardous Use 60 75 C rated copper wire 0 22Nm 2 lb in tightening torque for field installed conductors WARNING Do not operate the equipment in the presence of flammable gasses or fumes Operating electrical equipment in such an environment constitutes a definite safety hazard WARNING Ifthe eq
15. uipment is used in the manner not specified by N TRON Corp the protection provided by the equipment may be impaired WARNING Do not perform any services on the unit unless qualified to do so Do not substitute unauthorized parts or make unauthorized modifications to the unit WARNING Do not operate the unit with the end plates removed as this could create a shock or fire hazard WARNING Do not operate the equipment in a manner not specified by this manual WARNING Do not work on equipment or cables during periods of lightning activity WARNING Observe proper DC Voltage polarity when installing power input cables Reversing voltage polarity can cause permanent damage to the unit and void the warranty WARNING Install only in accordance with Local amp National Codes of Authorities Having Jurisdiction LASER SAFETY 1002MC and 1003GX2 Models CAUTION CLASS 1 LASER PRODUCT Do not stare into the laser Revised 8 5 2009 ENVIRONMENTAL SAFETY WARNINGS AX WARNING Disconnect the power and allow to cool 5 minutes before touching 1000 Series Industrial Gigabit Ethernet Switches The 1000 Series Unmanaged Industrial Gigabit Ethernet Switches support high speed layer 2 switching between ports This series of switches are housed in a ruggedized aluminum enclosure and provide Category 5 compliant 10 100 1000Base T connections for high performance network design and hub repeater upgrades All fiber products utilize the
16. ut Current Inrush Current Input Ripple Input Wire Size Environmental Operating Temperature Storage Temperature Operating Humidity Operating Altitude Network Media 10BaseT 100BaseT 1000BaseT Connectors 10 100 1000BaseTX 4 0 10 16 cm 1 0 2 54 cm 3 61 9 165 cm 0 70 Ibs 0 32 kg 35 mm 10 30 VDC Regulated 230mA max 24VDC Steady State 13 Amp 0 61 ms max 24VDC Less than 100 mV 16 28 AWG 40 C to 85 C 40 C to 85 C 10 to 90 Non Condensing O to 10 000 ft gt Cat 3 gt Cat 5 gt Cat Se Five 5 RJ45 TX Copper Ports Recommended Minimum Wiring Clearance Front 2 5 08 cm Top 1 2 54 cm Revised 8 5 2009 Regulatory Approvals Safety UL Listed per ANSI ISA 12 12 01 2000 US and Canada and listed for use in Class I Div 2 Groups A B C D T4 EMI EN61000 6 4 EN55011 Class A FCC Title 47 Part 15 Subpart B Class A ICES 003 Class A EMS EN61000 6 2 EN61000 4 2 ESD EN61000 4 3 RS EN61000 4 4 EFT EN61000 4 5 Surge EN61000 4 6 Conducted Disturbances Warranty 3 year from the date of purchase FE CES Revised 8 5 2009 18 N TRON Limited Warranty N TRON Corp warrants to the end user that this hardware product will be free from defects in workmanship and materials under normal use and service for the applicable warranty period from the date of purchase from N TRON or its authorized reseller If a product does
17. ut Voltage Input Current Inrush Current Input Ripple Input Wire Size Environmental Operating Temperature Storage Temperature Operating Humidity Operating Altitude Network Media 10BaseT 100BaseT 1000BaseT 1000BaseSX Multimode 1000BaseLX Singlemode Connectors 10 100 1000BaseTX 1000Base X SFP 4 0 10 16 cm 1 0 2 54 cm 3 61 9 165 cm 0 70 Ibs 0 32 kg 35 mm 10 30 VDC Regulated 200mA max 24VDC Steady State 13 Amp 0 8 ms max 24VDC Less than 100 mV 16 28 AWG 40 C to 85 C 40 C to 85 C 10 to 90 Non Condensing O to 10 000 ft gt Cat 3 gt Cat 5 gt Cat Se 50 62 5 125um 7 10 125um One 1 RJ45 TX Copper Port One 1 SFP LC Duplex Gigabit Fiber Port Recommended Minimum Wiring Clearance Front 5 12 70 cm Top 1 2 54 cm Revised 8 5 2009 Regulatory Approvals Safety UL Listed per ANSI ISA 12 12 01 2000 US and Canada and listed for use in Class I Div 2 Groups A B C D T4 EMI EN61000 6 4 EN55011 Class A FCC Title 47 Part 15 Subpart B Class A ICES 003 Class A EMS EN61000 6 2 EN61000 4 2 ESD EN61000 4 3 RS EN61000 4 4 EFT EN61000 4 5 Surge EN61000 4 6 Conducted Disturbances Warranty 3 year from the date of purchase FC Uus LISTED 65SN Revised 8 5 2009 14 1003GX2 KEY SPECIFICATIONS Physical Height Width Depth w typical SFP installed Weight DIN Rail Electrical I
Download Pdf Manuals
Related Search
Manual manual manualslib manual car manuale digitale manually meaning manual timesheet manual transmission manual wheelchair manual arts high school manually update your device drivers windows manual definition manual for courts martial manual labor manual lawn mower manual muscle testing manually register devices with autopilot manual muscle testing grades manual transfer switch manualidades manual blood pressure cuff manual handling manual transmission cars for sale manual digital manual pdf manual autopilot enrollment
Related Contents
CONTENIDO Pág. 1. OBJETIVO - Superintendencia de Industria y Yamaha FJ Automobile User Manual LO + DESTACADO ProLoop #2180 - Atrium Medical Samsung DVD-P181 Manual de Usuario 702219 Milli Flow MPC Manual Emtec Secure Digital Card 512MB Thermador MT27 User's Manual TRAINING - Chesapeake Employers Insurance Company Copyright © All rights reserved.