Home

USER MANUAL LL LED SPOT Z-POWER DC24V

image

Contents

1. LL39 400 LL LED SPOT RGB 3x0 35A LL39 410 LL LED SPOT AWB 3x0 35A LL39 430x LL LED SPOT OneColour 1x1 05A POWER SUPPLY MW 240 DIN 24V max 10A 100 260V AC Connecting LL LED SPOT to DIN POWER SUPPLY enables to switch ON OFF luminaries F LL LED SPOT connecting to PWM DRIVER and DIN POWER SUPPLY DMX CONTR INSTALLATION z Ventilation space 180 free minimal Ventilation space 90 free e RGB AWB version 7 minimal minimal 50mm POWER SUPPLY MW 240 DIN 24V Minimal mounting distance from surface 1 1 100 260V AC MOUNTING 90 OneColour version Non minimum distance and or Me sda 7 non use the original brackets is Aiming possibility Connecting LL LED SPOT to PWM DRIVER and DIN POWER SUPPLY enables to switch at your own risk The fixture could be aim to wish position with ON OFF luminaries and in addition intensity and colour control by DMX controller 22 bracket If you have any question please contact support leaderlight sk
2. 03 3 1 LL LED SPOT connecting to DC POWER SUPPLY for switch ON OFF luminaries 03 3 2 LLLED SPOT connecting to LL LED DRIVER for intensity and colour control 03 3 1 Connecting to DC power supply Figure Nr 2 1 LLLED SPOT must be connected to the device MW power supply IN 100 260AC OUT 24V It is not necessary to open fixture before connecting to MW power supply AC Power Supply Cord plug connections to MW Power Supply Symbol Pin Wire Colour Screw US L live brown yellow or brass N neutral blue silver ground earth yellow green green 03 3 2 Connecting to LL LED DRIVER Figure Nr 2 2 For intensity and colour control is necessary connection with LL LED DRIVER Itis not necessary to open fixture before connecting to LL LED DRIVER Before installing of LL LED DRIVER carefully read USER MANUAL for LL LED DRIVER 04 MAINTENANCE A To tackle all Safety Information 01 Damage caused by inadequate cleaning or maintenance is not coverd by warranty Regular cleaning is demand dust dirt Maintenance policy Unplug mains befor maintenance and at least 10 minutes cool off Cleanup dust from cover Use dampy duster warm watter Before reinstalling to check failure free state no wet parts Edition A 2008 If you have any question please contact support leaderlight sk OE eE E CEA LL LED SPOT connecting to DIN POWER SUPPLY
3. 6300K or Neutral White 3000K Lifetime Long 60 000 hrs 60 degradation Optic 25mm standard 25 optional 10 40 and 15 x90 on request Control data Input RGB AWB 3 channels 24V dimming OneColour 1 channel 24V dimming Input power max 25W DC Power Connection 24V DC 5m cable with 6 pin LINE connector Net weight 2 5kg Dimensions LxHx max 121mm x max 196mm x 125mm without bracket IP IP65 Ambient temp Ta Maximum 40 C Cooling Conventional Materials and finish Housing powder painted anodized aluminium RAL9006 other colours on request Cover clear or frosted PMMA Installation Any position for ceiling wall and surface mounting 03 INSTALLATION 03 1 Unpacking Unpack carefully This is electronic equipment and should be handled carefully Damaged delivered package or if are any mechanical parts broken it must be claim immediately by the transport company Photo pictures as evidence are valuable for future claim 03 2 Physical installation Loading capacity of bearing area has to be at least 10 times the weight of all device clusters luminaries clamps cables Heigrbreadth from combustible materials is 0 5m 03 3 Electrical installation Ad To tackle all Safety Information 01 You can suffer a dangerous electric shock by using a high voltage AC DC power supply by touching the AC DC power supply wires inside LL LED SPOT LLLED SPOT can be operated in two ways
4. Leader Light s r o M Gorkeho 33 SK 052 01 Spisska Nova Ves Slovakia www leaderlight eu USER MANUAL LEADER L GHT professional lighting products LL LED SPOT Z POWER DC24V COMPLIMENTS ON YOUR PURCHASE All dimensions are in milimeters max 121 amp Po Following items are included LL LED SPOT with 5 m cable and 6 PIN LINE connector 1 pc User manual 1 pe Additional items needed LED Driver DC power supply 24V Controller compatible with DMX Content 01 SAFETY INFORMATION 01 1 Risk of eyes damage 01 2 Protection from electric shock 01 3 Fire prevention 02 PRODUCT SPECIFICATION 02 1 Technical Specification 03 INSTALLATION 03 1 Unpacking 03 2 Physical installation 03 3 Electrical installation 03 3 1 Connecting to AC DC power supply 03 3 2 Connecting to LL LED DRIVER for intensity colour control 04 MAINTENANCE ENVIRONMENT COPY Lad Do not throw away the appliance with the normal household waste at the end of its life but hand it in at an official collection point for recycling By doing this you help to preserve the environment MMVIII Leader Light All right reserved 01 SAFETY INFORMATION A WARNING Carefully read before installing powering or servicing Nothing to do if anything misunderstand Only for professional use 01 1 Risk of eyes damage A Do not look directly into LED lamps Do not look into light beam from a distance o
5. f less than 40 cm 16 inches 01 2 Protection from electric shock A Shut down power before installation or maintenance Luminaries Driver and recommended power supply must be installed by a qualified professional in accordance with relevant local codes Only acceptable source of AC power and frequency that complies with local buidling and electrical codes to use Do not use or do not connect the products if the power cable power plug or fixtures are any way damaged wet or if they are overheating Do not modify alter or attempt to service the LeaderLight appliance Doing so will void the warranty Before removing or installing any cover or part of appliance disconnect it from AC power 01 3 Fire prevention A Follow all safety consideration Thermostatic switches or fuses never to bypass Device never shield Around the axis of the fitting 180 must be maintained space for cooling Minimum distance from the surrounding objects must be 50mm 2 in figure 1 1 LEDs never direct cover with filters or other materials Allowing max ambient temperature is 40 C 104 F Luminaries never use without mounting brackets The housing never install directly to the surface 02 PRODUCT SPECIFICATION 02 1 Technical Specification Lamp type RGB 5xR 5xG 5xB P4 Red Green and Blue AWB 5xA 5xW 5xB P4 Amber White 6300K and Blue OneColour 15xR G B A W N P4 Red or Green or Blue or Amber or White