1. INSTRUCTION MANUAL Star Cluster 150 otunning red and green star cluster effect laser M A N U AL V E R S IO N 1 0 14 05 12 Due to continuous product development please ensure that you have downloaded the latest instruction manual for this product from the Kam website at www kam co uk For the latest updates and information on the entire Kam range visit www kam co uk Kam products are manufactured by Lamba plc Unit 1 Southfields Road Dunstable Bedfordshire United Kingdom LU6 3EJ Telephone 44 0 1582 690600 Fax 44 0 1582 690400 Email mail lambaplc com Web www lambaplc com If this product is ever no longer functional please take it to a recycling plant for environmentally friendly disposal Due to continuous product development specifications and appearance are subject to change Copyright Lamba plc 2011 E amp OE Thank you for purchasing this KAM product we are sure that it will serve you for many years to come To optimise the performance of this product please read these operating instructions carefully to familiarise yourself with the basic operations of this unit After you have read the instructions please retain them for future reference This unit has been tested at the factory before being shipped to you To prevent or reduce the risk of electrical shock or fire do not expose the unit to rain or moisture To prevent a fire hazard do not expose the unit to any naked flame sources Unpl
2. you need to use adapter cables DMX controller not supplied e Connect the DMX output of the first fixture in the DMX chain with the DMX input of the next fixture Always connect output with the input of the nextfixture until all fixtures are connected e Ifyou use a controller with 5 pins DMX connector you need to use a 5 to 3pins adapter e The DMX output and input connectors are pass through to maintain the DMXcircuit when power is disconnected to the unit e Each fixture needs to have a DMX address to receive the data from the controller The DMX address number which could be read from rear panel of each fixture is between 000 511 1 di i oOo O DMX 512 12082 Controller operation n Master slave _ cE t operation t 1202 1202 Proper laser set up amp usage This fixture has been designed to be hung It is recommended for safety purposes your lighting effect are properly mounted using a suitable hanging clamp andsafety cable Items appropriate for safe and effective mounting are easilysourced from your lighting vendor International laser safety regulations require that lasers must be operated in thefashion illustrated below with a minimum of 3 metres 9 8 ft of vertical separation between the floor and the lowest laser light vertically Additionally 2 5 metres of horizontal separation is required between laser light and audience or other public spaces eer e N 3 Meters CAUTION U
3. LED panel will show 001 for DMX mode e Press ENTER to confirm the setting T on 5 Now the laser is working in DMX mode Ja Use the up down buttons to select the DMX address O FUNC UP DOWN ENTER Note In DMX MODE once the DMX cable is connected to the laser and DMX controller the DMX LED in front panel of laser will be ON DMX Protocol DMX Value 000 050 Laser Black Out 051 100 Ch 1 101 150 Sound activated show 151 200 DMX mode 1 201 255 DMX mode 2 DMX Mode 1 ie le Stop Counter clockwise rotation slow fast Swing range short long Blackout 051080 H No function Ch 5 Strobe DMX Mode 2 T Swing range short long 000 004 Blackout 005 010 Red S Ch 4 Red laser 011 254 Strobe slow fast 255 255 Strobe to sound 000 004 Blackout 005 010 PECORE 010 254 Strobe slow fast 255 255 Strobe to sound REM MODE Remote Optional e Press FUNC to enter the MODE selection e Use the up down buttons to select REM for Remote mode e Press ENTER to confirm the setting Please check Remote Instruction for remote control details Note In any standalone mode except REM and SLA press ON OFF for 2 seconds to activate the remote function Remote Instruction In REM mode to turn ON OFF laser In any stand alone ON OFF mode except for SLA mode pressing this button for 2 seconds will activate the REM mode Auto Auto running Sound Activated show The blue
4. it No user serviceable parts inside Refer all servicing to qualified service personnel The exclamation mark inside a triangle is intended to alert the user to the presence of important operating and maintenance instructions in the literature accompanying the appliance Any modification carried out on the unit may invalidate the unit s warranty If applicable only use the stand tripod or bracket specified or sold with the apparatus Select the installation location of your unit carefully Avoid placing it in direct sunlight or locations subject to vibration and excessive dust Do not use the unit where there are extremes in temperature below 41 F 5 C or exceeding 95 F 35 C Unpacking and safety Please unpack your new product carefully your new product should reach you in perfect condition Please check that no damage has occurred during transit If any damage is found do not operate your unit Please contact the retailer you purchased it from immediately If there is any damage to the mains cable do not use the device Always disconnect the unit from the mains supply when carrying out any servicing or cleaning of the unit The serial number for this equipment should be located on the rear or underside of the unit Please make a note of this number as you will need it for your warranty it is a good idea to keep a copy of the serial number for your own records Unpacking Instructions CAUTION Immediately upon receiving a fixture ca
5. music LED indicator is Music flashing when sound signal is detected Effect pause Pause the effect Cycle through the colours Red gt Green gt R amp G gt Colour changing Original Colour flashing A for Red flashing and B for Green flashing Firework effect Works with numbers Motor speed setting Works with numbers Level of colour flashing motor speed amp firework effect Number buttons O less 9 more Specifications Mains Input AC100 240V 50 60Hz Fuse 250V 1A Slow Blow 20mm Glass Total Power 20w Music Control Audio Sound Activated Laser Power per unit 100mW 650nm Red CW 5OmW 532nm Green CW Laser Classification Class 3B Laser Safety Standard EN60825 1 2007 Condition Temperature 10 40 C DMX Connections 3 pins XLR Male Female DMX Channels Max 5 channels Dimensions 160 x 180 x 260mm Nett weight 1 8Kg
6. refully unpack the carton check the contents to ensure that all parts are present and have been received in good condition Notify the shipper immediately and retain packing material for inspection if any parts appear damage from shipping or the package itself shows signs of mishandling Save the package and all packing materials In the event that a fixture must be returned to the retailer it is important that the fixture be returned in the original box and packing Contents 1 x laser 2 x keys for key switch 1 x interlock connector 1 x remote control 1 x power cord 1 x user manual 1 x laser safety guide Power Supply Cable EU Cable US Pin International FUSE 5mmx20mm LightBlue White Neutral N FUSE F 1 A 250V PN DMX 512 connection between fixtures The fixture is equipped with 3 pin XLR sockets for DMX input and output Thesockets are wired in parallel Only use a shielded twisted pair cable designed for3 pin XLR plugs and connectors in order to connect the controller with the fixtureor one fixture with another XLR connection DMX output DMX input XLR mounting sockets rear view XLR mounting plugs rear view 1 Shield 2 Signal 3 Signal Building a serial DMX chain e lf you are using a standard DMx controller you can connect the DMX output of the controller directly with the DMX input of the first fixture in the DMX chain If you wish to connect DMxX controllers with other XLR outputs
7. se of control adjustments or performance of procedures other than what is specified herein may result in hazardous radiation exposure Front Panel 1 Laser output Laser output aperture 2 Power Main power indicated LED Red is ON 3 Music IR Synchronize to detected music signal IR indicator flashing for each signal received 4 IR Infrared remote receiver N AASE ONTROL Rear Panel 5 Switch Switch on and off the power 6 Mains input with socket and intergrated fuse holder 7 DMX input 3 PIN Male XLR 8 DMX output 3 PIN Female XLR 9 Interlock For emergency laser stop 10 Key switch 11 Safety eye Attach the safety cable 12 Microphone to detect music sound 13 LED function display 3434 JOYS 1134YS HIVIN 343 AL34VS Operating Mode When the laser is powered on the LCD monitor on rear panel shows the current operating standalone mode DMX address or Slave mode With help of the LCD control panel it is very easy to set and change the operating mode of the laser The next time the laser is powered on it will show the last setting used before the laser was powered off FUNC Mode Option to choose the operating mode of laser ENTER Confirmation to confirm the selected mode UP DOWN to change operating mode parameter or DMX address DOWN Operation ENTER ENTER Display Stand alone mode pre programmed effect Automatic show with slow effect Sound ac
8. tivated show ATTENTION In pre programmed standalone MUSIC SHOW mode the laser beam will be blank out in 3 seconds without AUDIO MIC activated signal Standalone Pre program Laser Show e Press FUNC to enter MODE OPTION e Use the up down buttons to select either AUT or SOU e Press UP or DOWN to select your favourite Standalone mode as above e Press ENTER to confirm the setting The laser is working in stand alone Each time when you turn on your laser you will have this confirmed laser show AUTO SHOW Each time when you turn on your laser you will have this confirmed laser show SOUND ACTIVATED SHOW Each time when you turn on your laser you will have this confirmed laser show A ey I ao a eo o ie e FUNC UP DOWN ENTER FUNC UP DOWN ENTER MASTER SLAVE MODE e Press FUNC to enter the MODE selection e Use the up down buttons to select SLA for Slave mode e Press ENTER to confirm the setting Now the laser is working in SLAVE MODE Connect the MASTER laser with several SLAVE lasers using a DMX cable The SLAVE lasers will produce exactly the same laser show as MASTER laser SOUND ACTIVATED MODE SENSITIVITY SETTING e Press FUNC till to you see S 6 e Use the UP DOWN buttons to set microphone sensitivity S0 is no sound from S1 to S9 the sensitivity level increases CT 2 e Press ENTER to confirm and save the setting e eo o FUNC UP DOWN ENTER DMX MODE e Press FUNC to enter the MODE selection e The
9. ug this apparatus during lightning storms or if it is unlikely to be used for long periods of time When installing the unit please ensure you leave enough space around the unit for ventilation Slots and openings in the unit are provided for ventilation to ensure reliable operation of the product and to protect it from overheating To prevent fire hazard the openings should never be blocked or covered Always handle the power cable by the plug Never pull out the plug by pulling on the cable Never touch the power cable when your hands are wet as this could cause an electric shock Do not tie a knot in the cable The power cable should be placed such that it is not likely to be stepped on A damaged power cable can cause a fire or give you an electrical shock Check the power cord periodicaly if you ever find that it is damaged replace it before using the unit again Contact your retailer for a replacement The voltage of the available power supply differs according to country or region Be sure that the power supply voltage of the area where this unit is to be used meets the required written on the unit CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN The lightning flash symbol inside a triangle is intended to alert the user to the presence high voltage within the unit s enclosure that may be of sufficient power to constitute a risk of electrical shock to persons Caution to prevent the risk of electric shock do not attempt to open the un
Download Pdf Manuals
Related Search
Related Contents
発電水栓(アクアオート オールインワンタイプ) Ryobi P742 Use and Care Manual Droit au Logement Opposable (DALO) - format : PDF - Haute HQ B-032-1.5 JVC HR-V510E User's Manual Toyota 2005 Automobile User Manual 取扱説明書 Tripp Lite 375W PowerVerter Ultra-Compact Car Inverter with 2 Outlets Tecumseh AGA9539ZXNXF Performance Data Sheet Copyright © All rights reserved.