1. Power Suppl DDC System DC Power Supply 24 Ppa 4 20 mA Output Configuration The 4201 has 8 4 20 mA outputs It converts a digital signal entering at J15 into an analog signal through outputs J16 to J23 The output signal is linear to the input The 4 mA output represents the minimum scale from the input and the 20 mA output represents the maximum scale from the input 18 4201 User Manual 511399 Honeywell 2 07 Wiring Details PCB Terminals PCB Terminals E us ay A DD gt C vg Honeywell p2 P3 pa P7 PS o D E P D o o o 2 m e ES ADJUST 4mA po P10 P11 o y o p12 P13 Pra P15 P16 o D D el el CHANNEL 1 T oUTRUT1 8 SHIELD B A V gt moow E 5 Power and Communication J15 Input Lower Terminal Output Upper Terminal for communication use 2 24 AWG twisted and shielded cable Belden 9841 or equivalent J8 Pull down resistor J7 1 2 end of line resistor 2 3 end of line RC filter resistor J12 Pull up resistor 4 20 mA Outputs J16 to J23 4 20 mA outputs may be set to be Current sourcing or Loop powered Current Sourcing S2 to S9 jumpers at 1 2 3 4 and 5 6 Loop Powered S2 to S9 jumpers at 2 3 4 5 and 6 7
2. 26 D n gation de responsabilit d autres garanties 27 Limitation de responsabilit ss 27 511399 Manuel d utilisateur 4201 ix 2 07 Honeywell Introduction Introduction D ballage Des son ouverture v rifier le contenu de l emballage Assurez vous que vous avez re u tous les l ments tels qu indiqu s sur le bon de connaissement Directives d installation e Localiser chaque unit un endroit facilement accessible pour un technicien viter toute localisation des unit s pr s des sources de bruits lectriques et de vibrations e viter toute localisation des unit s pr s des sources de temp rature et d humidit instables e Avant de d buter l installation v rifier tous les codes normes ou l gislations pouvant affecter les travaux 511399 Manuel d utilisateur 4201 11 2 07 Honeywell Description Configurations disponibles Description Configurations disponibles Le convertisseur 4201 peut tre configur pour trois modes Dans une premi re configuration le convertisseur 4201 permet de lire les valeurs num riques transmises par les transmetteurs et de les convertir en signaux 4 20 mA Quoique l unit est configur es usine il est possible de modifier la configuration depuis le commutateur DIP de l unit voir la section Changer la configuration du 4201 Mode coute Dans ce mode le 4201 coute l infor
3. Mounting Instructions 1 Select installation location 2 Measure and mark mounting holes as shown 3 Pre drill or prepare as required by mounting surface drywall plugs etc 4 Position unit and align mounting holes with markings and install necessary screws Note Remember to remove knock outs before mounting the unit 511399 4201 User Manual 15 2 07 Honeywell Wiring Details 4 20 mA Current Sourcing Output Wiring Wiring Details 4 20 mA Current Sourcing Output Wiring The transmitter supplies the loop current The maximum impedance supported by the loop is 400 ohms To enable this configuration the three jumpers must be placed on positions 1 2 3 4 and 5 6 at distinct outputs J16 through J23 A dedicated power supply must be used with each unit WARNING Considerable damage may occur if this condition is not strictly met d g E d d d E RC EU a PD o e A Win u 1 A7 1 na 1 ss 1 seo CNN s2 1 J23 1 Power Supply DDC System 24 Vac 16 4201 User Manual 511399 Honeywell 2 07 Wiring Details 4 20 mA Output Loop powered Wiring 4 20 mA Output Loop powered Wiring Factory Setting The 4 20 m
4. When the output reads 3 33mA the 4201 does not see the corresponding transmitter WARNING A dedicated power source must be used with the 4201 when using current sourcing as input 4 20mA configuration 511399 4201 User Manual 19 2 07 Honeywell Specifications LED Descriptions Specifications Power requirement Number of outputs Operating temperature range Operating humidity range Communication cable Dimensions Weight Certifications 17 27 Vac 24 38 Vdc 500 mA 8 dedicated 4 20 mA outputs 20 to 50 C 4 to 122 F 0 95 RN non condensing 2 24 AWG twisted and shielded Belden 9841 or equivalent 8 4 in H x 8 6 in W x 2 5 in D 21 3 cm x 13 4 cm x 5 7 cm 3 5 lbs 1 58 kg with metal housing UL1244 CSA C22 2 no 205M1983 R1999 LED Descriptions PCB version 6 and before PCB version 7 and up LED 1 Power LED 4 Digital to analog signal DAC LED 5 Micro controller LD5 Power LD2 Fault D6 Communication LED 20 4201 User Manual Honeywell 511399 2 07 Specifications 4 20 mA Output Adjustments 4 20 mA Output Adjustments Before changing the S1 DIP switch settings for the 4 20 mA adjustments note the actual setting to reset the dip switch for normal operation After the adjustments are made replace jumpers at S2 through S9 to the correct configuration The outputs must be set for current sourcing configuration Install jump
5. 0 0 1 O 1 1 0 Modbus listen Adr 41 48 0 0 0 041 1 1 1 0 Modbus listen Adr 49 56 000101 o O 0 1 Modbus listen Adr 57 64 0 0 O 0 1 1 O 0 1 Modbus listen Adr 65 72 g0 0 0 1 fO 1 0 1 Modbus listen Adr 73 80 3 0 0 Of 0 1 1 1 0 1 Modbus listen Adr 81 88 D o 0 0 04 0 O 1 1 Modbus listen Adr 89 96 zio 0 Wen 1 o 1 1 Not Available 8 o 0 0 01 O 1 1 1 Not Available 2 0 0 00h 1 1 1 1 Not Available Note When DIP Switch four 4 is set to 1 it is in statistic mode except for adjustment settings 22 420l User Manual 511399 Honeywell 2 07 Limited Warranty Limited Warranty Limited Warranty Honeywell Analytics Inc warrants to the original purchaser and or ultimate customer Purchaser of Vulcain products Product that if any part thereof proves to be defective in material or workmanship within twelve 12 months such defective part will be repaired or replaced free of charge at Honeywell Analytics discretion if shipped prepaid to Honeywell Analytics at 4005 Matte Blvd Unit G Brossard Quebec J4Y 2P4 in a package equal to or in the original container The Product will be returned freight prepaid and repaired or replaced if it is determined by Honeywell Analytics that the part failed due to defective materials or workmanship The repair or replacement of any such defective part shall be Honeywell Analytics sole and exclusive responsibility and liability under this limited warranty Re Stockin
6. 20 mA Borniers de raccordement lectrique Ep PCB420IR8 ade m Canada 508848 4 ADJUST4mA o a i a E E E E E E PE T C D Je i FT COUTRUT 1 8 a ES SHIELD B A V V E A A Alimentation et Communication J15 Entr e Bornier du bas Sortie Bornier du haut B J8 R sistance pull down C J7 Position 2 3 Filtre RC fin de ligne Position 1 2 R sistance de fin de ligne D J12 R sistance pull down E Entr e 4 20mA J16 J23 Sorties 4 20 mA peuvent tre utilis es pour configuration active ou passive Configuration Active Cavaliers S2 S9 sur 1 2 3 4 et 5 6 Configuration Passive Cavaliers S2 S9 sur 2 3 4 5 et 6 7 Quand la sortie lit 3 33 mA le 4201 ne d tecte pas le transmetteur correspondant ATTENTION Une alimentation s par e pour chaque unit est requise pour cette configuration 20 Manuel d utilisateur 4201 511399 Honeywell 2 07 Sp cifications D finition des DEL Sp cifications Alimentation requise Nombre de sorties Plage de temp rature Plage d humidit C ble de communication Dimensions Poids Certifications 17 27 Vca 24 38 Vcc 500 mA 8 sorties d di es 4 20 mA 20 50 C 4 1220 F 0 95 RH non condens 2 24 AWG torsad et blind Belden 9841 ou quivalent
7. 21 3 cm H x 13 4 cm L x 5 7 cm P 1 58 Kg 3 5 lbs bo tier en m tal UL1244 CSA C22 2 no 205M1983 R1999 D finition des DEL Version 6 et plus r cent Version 7 et plus r cent DEL 1 Alimentation DEL 4 Convertisseur analogue num rique DEL 5 Micro contr leur LD5 Alimentation LD2 Faute D6 Communication 511399 Manuel d utilisateur 4201 21 2 07 Honeywell Sp cifications Ajustements des sorties 4 20 mA Ajustements des sorties 4 20 mA Avant de changer les r glages des commutateurs DIP de S1 pour les ajustements 4 20 mA veuillez prendre note des r glages existants pour op ration normale Apr s B avoir fait les ajustements remettez les cavaliers de S2 S9 en position correcte Les sorties doivent tre r gl es pour la configuration active Installez les cavaliers aux positions 1 2 3 4 et 5 6 de S2 S9 Si la ligne sera mise sous tension ne PAS utiliser la ATTENTION configuration active Reglez le commutateur DIP S1 comme suit pour les ajustements 4 mA Dip1 OFF Dip2 OFF Dip3 ON Dip4 OFF Avec l amp rem tre chaque sortie ajustez le 4 mA l aide des potentiom tres P9 P16 Reglez le commutateur DIP S1 comme suit pour les ajustements 20 mA Dip1 OFF Dip2 ON Dip3 ON Dip4 OFF Avec l amp rem tre chaque sortie ajustez le 20 mA l aide des potentiom tres P1 P8 Aussit t termin ne pas oublier de remet
8. Belgium Honeywell International Inc Sunrise Florida U S A 954 845 2600 Latin America Sales Informations Contact us at sales vulcaininc com 511399 4201 User Manual 2 07 Honeywell Symbol Definitions The following table lists the symbols used in this document to denote certain conditions Symbol Definition ATTENTION Identifies information that requires special consideration TIP Identifies advice or hints for the user often in terms of performing a task REFERENCE _ INTERNAL Identifies an additional source of information within the bookset E au y Indicates a situation which if not avoided may result in equipment or work data on the system being damaged or lost or may result in the inability to properly operate the process CAUTION Indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury It may also be used to alert against unsafe practices A CAUTION Symbol on the equipment refers the user to the product manual for additional information The symbol appears next to required information in the manual WARNING Indicates a potentially hazardous situation which if not avoided could result in serious injury or death WARNING symbol on the equipment refers the CAUTION user to the product manual for additional information The symbol appears next to required information in the manual 511399 4201 User Manual
9. r parations sont n cessaires sur le produit retourn les frais de cette r paration seront d duit du cr dit Auncun cr dits ne seront appliqu s pour les retours apr s les 3 mois suivant la date d exp dition 511399 Manuel d utilisateur 4201 25 2 07 Honeywell Exclusions A Si des capteurs de gaz font partie du Produit le capteur est couvert par une garantie limit e de douze 12 mois du fabricant B Siles capteurs de gaz sont couverts par cette garantie limit e le capteur sera assujeti a l inspection par Honeywell Analytics pour l exposition prolong e des concentrations de gaz lev es si l Acheteur fait une r clamation sous cette garantie limit e SI l inspection indique que la cause de la d fectuosit est l puisement du capteur plut t qu un d faut cette garantie ne s appliquera pas au Produit C Cette garantie limit e ne s applique pas au produits consommables tels les piles ou les articles sujets l usure ou au remplacement r gulier incluant les lampes les fusibles les valves les aubes les lements de sonde les cartouches ou les l ments de filtres Limitation et exclusion de la garantie Honeywell Analytics n aura aucun autre responsabilit sous cette garantie limit e Toutes responsabilit s de garantie d Honeywell Analytics sont annul es si le Produit a subi des abus de la n gligeance un accident ou si l Acheteur est en d faut de ses obligations tels que d crit dans cette gara
10. to channel 2 Split Address Mode Listening or Polling This mode is used with a SQN8x 4 points 2 gases The SQN8x uses 4 points per gas Addresses 1 to 4 are for the first gas and addresses 9 to 12 for the second gas On the 4201 the addresses are fixed Addresses 1 to 4 are attributed to the first 4 outputs and addresses 9 to 12 are attributed to the last 4 outputs This configuration allows for the use of only one 4201 with a SQN8 amp x with two gases 511399 4201 User Manual 13 2 07 Honeywell Description Available Configuration for 301C Available Configuration for 301C This function is only available with recent versions 2005 onward When used with the 301C it is in listening mode only the broadcast mode must be activated on the controller side Addresses can be selected in groups of 8 i e 1 8 9 16 and so on until 89 96 See DIP Switch settings for further details There are also three 3 statistic values available for selected groups Minimum Maximum and Average Each converted signal is associated to the following outputs Output J20 Average Output J18 Minimum Output J16 Maximum 14 4201 User Manual 511399 Honeywell 2 07 Installation Mounting Instructions Installation Installation of the converter simply requires the physical mounting of the enclosure and connection of the power and output lines Honeywell 6 13 32 10916 5 0
11. utilisateur la documentation pour de plus amples informations Ce symbole apparait c t des informations n cessaires dans le manuel 511399 2 07 Manuel d utilisateur 4201 vii Honeywell Table des mati res INTRODUCTION 2 11 D ballage icine ees Hann ENEE Ed 11 Directives d installation AA 11 DESCRIPTION scsi 12 Configurations disponibles nn 12 okt EST EE 12 Mode interrogation in 13 Mode adresse divis e coute ou interrogation 13 Configuration disponible pour 3010 2uussnseensnnnnnnnnnnnnnnnnn ann 14 INSTALLATION cuina 15 Instructions de montage sse 15 D TAILS DE CONNEXION ms 16 Configurations 4020 mA sse nennen 16 La configuration active 16 La configuration passive roiroi aani na E Eana 17 Configuration F fils rennen 18 Configuration 4 fils AE 18 Les sorties 4 20 MA iii 19 BORNIERS DE RACCORDEMENT LECTRIQUE 20 SP CIFICATIONS is 21 D finition des DEL a de de Ter stacks 21 Ajustements des sorties 4 20 mA sse 22 CHANGER LA CONFIGURATION DU 4201 23 R glages commutateurs DIP u znsusssnensnsnnnnnsnnnnnannnonnnnnnnnnannnnnn 23 Garantie limit e ss 25 Politique d Retour 4 pire tm ea 25 Exclusions ee ie Hain ieee ie 26 Limitation et exclusion de la garantie
12. vii 2 07 Honeywell Contents INTRODUCTION ecissic abaci aae vnu sa dana uad iu auo enda dnas 11 Unpacking nesrin e tre ea 11 Description Learn EI ia 11 Installation Guidelines A 11 INSTALLATION 2 2 12 AVAILABLE CONFIGURATIONS 13 Eistening MOGde 44 n ge pe Hee el ai eee 13 Polling Ae e TEE 14 Split Address Mode ue 3 edet tret tee dodi bate 14 Available Configuration for 201 15 4 20 mA Configuration sssssssssseseseeee eene 16 4 20 mA Output Loop powered Operation ssseessss 17 4 20 mA Output Configuration sesseeeseeeeeeeeeesireerreerrrerirrerrrerrnsere 19 WIRING DETAILS 4 2 20 SPECIFICATIONS au ind rias 21 LED Position and Significance ssssseeeees 21 4 20 mA Output Adjustments sssssseeeennenns 21 DIP Switch Settings AAA 23 LIMITED WARRANTY ccccesseeeeeeeeeeeeeeeeeeeeeeeenseseeees 25 Limited Ee eee rra ni dr 25 Re Stocking Poli Yeti ee ne eel 25 Le EEN 26 Warranty Limitation and Exclusion 26 Disclaimer of Unstated Warranties AAA 27 Limitation of Liability zero code o de ta 27 510977 4201 User Manual ix 2 07 Honeywell Introduction Unpacking After opening the package and removing the equipment and components make sure that you have all the items described on the order form or packing slip Installation Gu
13. A output is factory set for loop powered operation and requires a power source of 12 Vdc to 30 Vdc The overall permitted impedance depends on the voltage supplied at the 4 20 mA loop To enable this configuration the three jumpers must be placed on positions 2 3 4 5 and 6 7 at distinct outputs J16 through J23 Permitted Impedance in the 4 20 mA Loop Voltage Source Applied Total Impedance 12 Vdc 400 Ohms 16 Vdc 600 Ohms 20 Vdc 800 Ohms 24 Vdc 1000 Ohms 30 Vdc 1300 Ohms 3 wire configuration e d E g g d i ne se PU E P D 3 En e A el s A D e Jg 1 A 1 na ng J20 1 Jar 1 42 1 ourdur d a J DDC System DC Power Supply 511399 4201 User Manual 17 2 07 Honeywell Wiring Details 4 20 mA Output Loop powered Wiring 4 wire configuration i R g d k s im RC Eu E Dien 3 E n n E ne 1 n7 1 mg 49 1 J20 1 M 1 2 1 Jas
14. Convertisseur de signaux num riques Digital Signal Converter Manuel de l utilisateur 4201 User Manual ERP 511399 2 07 Digital Signal Converter 4201 User Manual ERP 511399 2 07 Notices and Trademarks Copyright by Honeywell International Inc Release 511399 February 2007 While this information is presented in good faith and believed to be accurate Honeywell disclaims the implied warranties of merchantability for a particular purpose and makes no express warranties except as may be stated in its written agreement with and for its customers In no event is Honeywell liable to anyone for any indirect special or consequential damages The information and specifications in this document are subject to change without notice Honeywell Analytics 4005 Matte Blvd Unit G Brossard Quebec J4Y 2P4 511399 4201 User Manual iii 2 07 Honeywell Contacts World Wide Web The following Honeywell Websites may be of interest to Industry Solution customers Honeywell Organization WWW Address URL Honeywell Analytics http www honeywellanalytics com Corporate http www honeywell com International http content honeywell com global Telephone Contact us by telephone at the numbers listed below Organization Phone Number 1 800 563 2967 u Honeywell Analytics 1 450 619 2450 Fax 1 888 967 9938 Asia Pacific Honeywell Asia Pacific Inc 852 23 31 9133 Hong Kong Europe Honeywell Pace 32 2 728 2711 Brussels
15. J16 J23 Une alimentation s par e pour chacun des 4201 est requise pour cette configuration D importants dommages peuvent survenir si les conditions ci haut mentionn es ne sont pas correctement suivies ATTENTION e c EOL E PAD LAS LALA LALA Alimentation Syst me DDC 24 Vca 16 Manuel d utilisateur 4201 511399 Honeywell 2 07 D tails de connexion La configuration passive La configuration passive Configuration r gl e en usine Configur es en 4 20 mA passif les sorties n cessitent une alimentation de 12 Vcc 30 Vcc Limp dance totale permise d pend du voltage de l alimentation de la boucle 4 20 mA Pour configurer ce mode il faut placer les trois cavaliers des boucles dans la position 2 3 4 5 et 6 7 Les tiquettes des cavaliers des boucles de 1 8 sont respectivement J16 J23 Imp dance permise dans la boucle 4 20 mA Source de diff rence de l Imp dance Total potentiel voltage appliqu 12 Vdc 400 Ohms 16 Vdc 600 Ohms 20 Vdc 800 Ohms 24 Vdc 1000 Ohms 30 Vdc 1300 Ohms 511399 Manuel d utilisateur 4201 17 2 07 Honeywell D tails de connexion La configuration pa
16. er is connected to channel 2 Each converted signal is associated to a distinct output J16 through J23 Three statistic values are also available Minimum Maximum and Average with the appropriate settings These values are available with addresses 1 to 8 9 to 16 or 1 to 16 if the converter is connected to channel 1 of the 201C or 17 to 24 25 to 32 or 17 to 32 if the converter is connected to channel 2 The outputs associated with the statistic mode are the following Output J20 Average Output J18 Minimum Output J16 Maximum 12 4201 User Manual 511399 Honeywell 2 07 Description Available Configurations Polling Mode In this mode the converter polls the network There is no 201C on the network The 4201 master polls the transmitters slaves and converts the digital signal from the transmitters into a 4 20 mA analog signal Once set the converter provides a 4 20 mA analog signal for the transmitters at address 1 to 8 or 9 to 16 if the converter is connected to channel 1 of the 201C and 17 to 24 or 25 to 32 if the converter is connected to channel 2 Each converted signal is associated with a distinct output J16 through J23 Three statistic values are also available Minimum Maximum and Average with the appropriate settings These values are available with addresses 1 to 8 9 to 16 or 1 to 16 if the converter is connected to channel 1 of the 201C or 17 to 24 25 to 32 or 17 to 32 if the converter is connected
17. ernational Inc Sunrise Floride E U Asie Pacifique 852 23 31 9133 Europe 32 2 728 2711 Am rique latine 954 845 2600 Informations des ventes Nous contacter sales vulcaininc com 511399 Manuel d utilisateur 4201 2 07 Honeywell D finitions des symboles Le tableau suivant contient la liste des symboles utilis s dans ce document pour indiquer certaine conditions Symbole D Ei ATTENTION A D finition ATTENTION identifie une information demandant une attention sp ciale Truc Identifie un conseil ou un truc pour l utilisateur souvent concernant une t che R F RENCE INTERNE Indique une source d information suppl mentaire l int rieur du document Indique une situation viter pouvant entrainer des dommages au syst me ou la perte de travail documents ou pouvant pr venir l op ration normale du syst me ATTENTION Indique une situation potentiellement dangereuse qui peut entrainer des blessures mineures ou mod r es si pas vit Peut galement signaler des actions dangereuses ATTENTION Un symbole sur l quippement qui r f re l utilisateur la documentation pour de plus amples informations Ce symbole appara t c t des informations n cessaires dans le manuel AVERTISSEMENT Indique une situation potentiellement dangereuse qui peut entrainer des blessures majeures ou la mort si pas vit AVERTISSEMENT Un symbole sur l quippement qui r f re l
18. ers at positions 1 2 3 4 and 5 6 for S2 through S9 Do NOT use Current Sourcing Configuration if there will be WARNING voltage on the line Set Dipswitch S1 as follows for 4 mA adjustment Dip1 OFF Dip2 OFF Dip3 ON Dip4 OFF With your ampmeter at each output adjust the 4 mA with Potentiometers P9 through P16 Set Dipswitch S1 as follows for 20 mA adjustment Dip1 OFF Dip2 ON Dip3 ON Dip4 OFF With your ampmeter at each output adjust the 20 mA with potentiometers P1 through P8 Once completed replace the settings to their original places 511399 4201 User Manual 21 2 07 Honeywell Changing the 4201 Configuration DIP Switch Settings Changing the 4201 Configuration DIP Switch Settings 1 2 3 4 5 6 7 8 Mode 0 0 0 01 0 O 0 0 interrogation mode Adr 9 16 10 0 0410 O D 0 Interrogation mode Adr 1 8 0 1 0 01 10 O 0 0 Listen mode Adr 9 16 1 1 0 04 O O 0 D Listen mode Adr 1 8 ONO EO 0 0 D 0 Output adjustment 4mA 2 1 0 110410 0 00 ao mode split adr 1 4 amp OT EO 0 0 O 0 Output adjustment 20mA 2 1 1 1 04 O O 0 0 Listen mode split adr 1 4 9 12 a 0 0 1 1 0 0 O D Interrogation mode statistic 1 16 gt 0 1 1 1 O 0 O O Listen mode statistic 1 16 000101 1 O 0 0 Modbus listen Adr 1 8 o 0 0 01 0 1 0 0 Modbus listen Adr 9 16 o 0 0 0f 1 1 O 0 Modbus listen Adr 17 24 000101 0 0 1 O0 Modbus listen Adr 25 32 0 0 0 0 1 O 1 0 Modbus listen Adr 33 40 0 0
19. g Policy The following re stocking fees will apply when customers return products for credit e 15 re stocking fee will be applied if the product is returned within 1 month following the shipping date e 30 re stocking fee will be applied if the product is returned within 3 months following the shipping date A full credit less re stocking fee will only be issued if the product is in perfect working condition If repairs are required on the returned product the cost of these repairs will be deducted from the credit to be issued No credits will be issued beyond the three month period 511399 4201 User Manual 25 2 07 Honeywell Limited Warranty Exclusions a lf Gas sensors are part of the Product the gas sensor is covered by a twelve 12 month limited warranty of the manufacturer b If gas sensors are covered by this limited warranty the gas sensor is subject to inspection by Honeywell Analytics for extended exposure to excessive gas concentrations if a claim by the Purchaser is made under this limited warranty Should such inspection indicate that the gas sensor has been expended rather than failed prematurely this limited warranty shall not apply to the Product c This limited warranty does not cover consumable items such as batteries or items subject to wear or periodic replacement including lamps fuses valves vanes sensor elements cartridges or filter elements Warranty Limitation and Exclusion Honeywel
20. i de suite jusqu 113 120 Voir la section de R glages commutateurs DIP pour de plus amples informations Il y a galement trois valuers de statistiques disponibles Minimum Maximum et Moyenne Chaque signal convertit est associ l une des sorties suivantes Sortie J20 Moyenne Sortie J18 Minimum Sortie J16 Maximum 14 Manuel d utilisateur 4201 511399 Honeywell 2 07 Installation Instructions de montage Installation L installation du convertisseur n cessite simplement le montage mural et le raccordement lectrique Le 10916 x Instructions de montage 1 Choisir l emplacement pour l installation 2 Mesurer et marquer les trous de montages selon l illustration 3 Perger ou pr parer les trous de montage selon la surface ancrages etc 4 Aligner l unit eavec les trous puis affixer avec les vis appropri es Note Enlever les pastilles poinconn es knock out avant de fixer l unit 511399 Manuel d utilisateur 4201 15 2 07 Honeywell D tails de connexion Configurations 4 20 mA D tails de connexion Configurations 4 20 mA La configuration active Le convertisseur fournit la tension la boucle de courant Limp dance maximale que peut supporter la boucle est de 400 Ohms Pour configurer ce mode il faut placer les trois cavaliers de boucles dans la position 1 2 3 4 et 5 6 Les tiquettes des cavaliers des boucles de 1 8 sont respectivement
21. idelines Make sure to locate the monitor in an area easily accessible to a technician e Avoid any location where temperature changes occur rapidly e Verify all the requirements and existing regulations which may affect the choice of location e Conduit installation must conform to local fire building and electrical codes 511399 4201 User Manual 2 07 Honeywell Description Available Configurations Description The unit can be factory set to one of three configurations In the most standard configuration the 4201 converts the transmitter digital signal to 4 20 mA analog outputs Although the unit is preconfigured it is also possible to modify configurations using the units DIP switch see Changing the 4201 Configuration section Available Configurations This section provides details on the various 4201 configurations available as well as various wiring diagrams The 4201 converter may be configured in three modes Listening Polling and Split Address Listening Mode In this mode the 4201 only listens to the information transmitted between the controller and the transmitters It does not intervene in network operation The converter transforms the digital signal from the transmitters into a 4 20 mA analog signal Once set the converter provides a 4 20 mA analog signal for the transmitters at addresses 1 to 8 or 9 to 16 if the converter is connected to channel 1 of the 201C and 17 to 24 or 25 to 32 if the convert
22. l Analytics will have no further obligation under this limited warranty All warranty obligations of Honeywell Analytics are extinguishable if the Product has been subject to abuse misuse negligence or accident or if the Purchaser fails to perform any of the duties set forth in this limited warranty or if the Product has not been operated in accordance with instructions or if the Product serial number has been removed or altered 511399 4201 User Manual 26 2 07 Honeywell Limited Warranty Disclaimer of Unstated Warranties The warranty printed above is the only warranty applicable to this purchase All other warranties express or implied including but not limited to the implied warranties of merchantability or fitness for a particular purpose are hereby disclaimed Limitation of Liability It is understood and agreed that Honeywell Analytics liability whether in contract in tort under any warranty in negligence or otherwise shall not exceed the amount of the purchase price paid by the purchaser for the product and under no circumstances shall Honeywell Analytics be liable for special indirect or consequential damages The price stated for the product is a consideration limiting honeywell analytics liability No action regardless of form arising out of the transactions under this warranty may be brought by the purchaser more than one year after the cause of actions has occurred 511399 4201 User Manual 27 2 07 Honey
23. mation transig e entre le contr leur 201C et des transmetteurs Le convertisseur transforme les signaux num riques des transmetteurs en signaux analogiques 4 20 mA Le convertisseur fournit la conversion analogique des signaux pour les transmetteurs 1 8 ou 9 16 si le convertisseur est branch au canal 1 du contr leur 201C et 17 24 ou 25 32 si le convertisseur est branch au canal 2 du contr leur Chaque signal est fourni sur une sortie distincte J16 J23 Les trois valeurs statistiques minimale maximale et la moyenne sont aussi disponibles par r glage pour les transmetteurs 1 8 9 16 ou 1 16 si le convertisseur est branch au canal 1 du contr leur 201C et 17 24 25 32 ou 17 32 si le convertisseur est branch au canal 2 du contr leur Trois sorties distinctes fournissent la valeur minimale J18 la valeur maximale J16 et le moyenne J20 des unit s en coute 12 Manuel d utilisateur 4201 511399 Honeywell 2 07 Description Configurations disponibles Mode interrogation Le mode interrogation est utilis en l absence de contr leur 201C Le convertisseur interroge les transmetteurs et convertit les signaux num riques des transmetteurs en signaux analogiques 4 20 mA Le convertisseur selon le r glage fournit la conversion analogique des signaux pour les transmetteurs 1 8 ou 9 16 si le convertisseur est branch au canal 1 du contr leur 201C et 17 24 ou 25 32 si le c
24. ntie ou si le Produit n a pas t utilis selon les instructions ou si le num ro de s rie du Produit t enlev ou modifi 511399 Manuel d utilisateur 4201 26 2 07 Honeywell D n gation de responsabilit d autres garanties La garantie ci haut est la seule garantie applicable cet achat Toutes autres garanties soit implicites ou expr s incluant mais pas limit les garanties tacites de qualit marchande ou de l aptitude un emploi particulier sont d n gu es par le pr sent document Limitation de responsabilit Il est entendu que la responsabilit d Honeywell Analytics soit en contrat en d lit civil sous n importe quelle garantie de responsabilit en n gligence ou autrement n exc dera pas le prix d achat pay par l Acheteur pour le produit Honeywell Analytics ne sera pas responsable sous aucune circonstance pour des dommages sp ciaux ou indirectes Le prix d clar pour le produit est une consid ration limitant la responsabilit d Honeywell Analytics Aucune action en quelle forme que soit survenant des transactions sous cette garantie peuvent tre entreprises par l Acheteur plus d un an apr s l occurence de la cause de ces actions 511399 Manuel d utilisateur 4201 27 2 07 Honeywell
25. onvertisseur est branch au canal 2 du contr leur Chaque signal est fourni sur une sortie distincte J16 J23 Les trois valeurs statistiques minimale maximale et la moyenne sont aussi disponibles par r glage pour les transmetteurs 1 8 9 16 ou 1 16 si le convertisseur est branch au canal 1 du contr leur 201C et 17 24 25 32 ou 17 32 si le convertisseur est branch au canal 2 du contr leur Trois sorties distinctes fournissent la valeur minimale J18 la valeur maximale J16 et le moyenne J20 des unit s en interrogation Mode adresse divis e coute ou interrogation Ce mode est utilis avec un SQN8X lorsque ce dernier a 4 points 2 gaz En effet ce mode permet l interrogation ou l coute des 4 points pour chacun des gaz Les adresses 1 4 pour le premier gaz et les adresses 9 12 pour le deuxi me gaz Sur le 4201 les sorties attribu es sont J16 J19 pour les adresses 1 4 et J20 J23 pour les adresses 9 12 Ceci permet d utiliser un seul 4201 511399 Manuel d utilisateur 4201 13 2 07 Honeywell Description Configuration disponible pour 301C Configuration disponible pour 301C Cette fonction est seulement disponible sur les version 7 et plus du 301C Lorsque utilis avec le 301C ce dernier est en mode coute seulement le mode broadcast doit tre activ dans la centrale Les adresses peuvent tre s lectionn es en groupes de 8 soit 1 8 9 16 et ains
26. ssive Configuration 3 fils an e Bow Ba Clees SHIELD B A Syst me DDC Alimentation Vcc Configuration 4 fils 18 ss n so E s rm se MEL vs 1 x A E ES i Alimentati Syst me DDC Alimentation re Manuel d utilisateur 4201 511399 Honeywell 2 07 D tails de connexion Les sorties 4 20 mA Les sorties 4 20 mA Le 4201 contient 8 sorties 4 20mA Le 4201 convertit un signal num rique entrant par J15 en un signal analogique 4 20mA fourni aux sorties J16 J23 La sortie est lin aire l entr e Le signal 4mA de la sortie repr sente la valeur minimum de la plage du signal d entr e et le signal 20mA repr sente la valeur maximale de la plage du signal d entr e 511399 Manuel d utilisateur 4201 19 2 07 Honeywell Borniers de raccordement lectrique Les sorties 4
27. stique sauf ceux en mode ajustement 511399 2 07 Manuel d utilisateur 4201 Honeywell 23 Garantie limit e Garantie limit e Honeywell Analytics Inc garantie l Acheteur d origine et ou au client final Acheteur gt de produits Vulcain Produit que si une pi ce quelconque du produit s av re d fectueuse soit en mat riel ou en main d oeuvre dans les douze 12 mois cette pi ce sera r par e ou remplacer sans frais la discr tion d Honeywell Analytics si exp di port pay Honeywell Analytics at 4005 Matte Blvd Unit G Brossard Quebec J4Y 2P4 dans l emballage d origine ou l quivalent Le Produit sera retourn au client port pay si Honeywell Analytics d termine que la pi ce est d fectueuse en raison de d faut mat riel ou de main d oeuvre La r paration ou le remplacement d une telle pi ce d fectueuse repr sente la seule et exclusive responsabilit d Honeywell Analytics sous cette garantie limit e Politique de Retour Les frais suivants seront applicables lors de retour de produit pour cr dit Des frais de retour de 15 seront appliqu s lorsque le produit est retourn dans le 1er mois suivant la date d exp dition Des frais de retour de 30 seront appliqu s lorsque le produit est retourn dans les 3 mois suivant la date d exp dition Un cr dit total moins les frais de retour sera uniquement appliqu si le produit est en parfait tat de fonctionnement Si des
28. tre les param tres d origine 22 Manuel d utilisateur 4201 511399 Honeywell 2 07 Changer la configuration du 4201 R glages commutateurs DIP Changer la configuration du 4201 R glages commutateurs DIP 12 3 5 6 7 Mode 0 0 0 04 JO 0 0 0 Mode interrogation Adr 9 16 1 0 0 04 JO 0 0 0 Mode interrogation Adr 1 8 G 0 1 0 0 1 0 0 0 0 Mode coute Adr 9 16 5 1 1 0 0 1 0 0 0 0 Mode coute Adr 1 8 lo o 1 o lo o 0 0 Ajustment sortie 4mA 2 1 0 1 01 0 0 0 0 Mode interrogation adr div 1 4 9 12 S 0 1 1 0 0 0 0 0 Ajustment sortie 20mA gt 1 1 1 0 1 0 0 0 0 Mode coute adr div 1 4 9 12 0 0 1 1 0 0 0 0 Interrogation mode statistique 1 16 0 1 1 1 0 0 0 0 Mode coute statistique1 16 0 0 0 0 1 1 0 0 0 Modbus coute Adr 1 8 0 0 0 0 1 0 1 0 0 Modbus coute Adr 9 16 0 0 0 0 1 1 1 0 0 Modbus coute Adr 17 24 0 0 0 0 1 0 0 1 0 Modbus coute Adr 25 32 0 0 0 0 1 1 0 1 0 Modbus coute Adr 33 40 o 0 0 0 0 1 0 1 1 0 Modbus coute Adr 41 48 8 0 0 0 0 1 1 1 1 0 Modbus coute Adr 49 56 2 0 0 0 0 1 0 0 0 1 Modbus coute Adr 57 64 m 0 0 0 0 1 1 0 0 1 Modbus coute Adr 65 72 Olo 0 0 0 1 0 1 0 1 Modbus coute Adr 73 80 0 0 0 0 1 1 1 0 1 Modbus coute Adr 81 88 0 0 0 0 1 0 0 1 1 Modbus coute Adr 89 96 0 0 0 0 1 1 0 1 1 Non disponible 0 0 0 04 JO 1 1 1 Non disponible 0 0 0 0 1 1 1 1 1 Non disponible Note Lorsque le commutateur 4 est en position 1 il est en mode stati
29. well Convertisseur de signaux num riques 4201 Manuel d utilisateur ERP 511399 2 07 Avis et marques de commerce Tous droits r serv s par Honeywell International Inc Parution 511399 f vrier 2007 Quoique cette information est pr sent e en bonne foi et est pr sum e exacte Honeywell d cline la garantie tacite de la qualit marchande pour un emploi particulier et offre aucune garantie expr s l exception des conventions crites avec et pour ses clients Honeywell ne sera sous aucune circonstance responsable qui que ce soit pour des dommages sp ciaux ou indirectes Les informations et les sp cifications dans ce document sont susceptibles d tre modifi es sans pr avis Honeywell Analytics 4005 Matte Blvd Local G Brossard Qu bec J4Y 2P4 511399 Manuel d utilisateur 4201 iii 2 07 Honeywell Nous joindre Web Les sites Web suivant d Honeywell peuvent tre utilies pour les clients d Industry Solution Organisation Honeywell Adresses WWW URL Honeywell Analytics http www honeywellanalytics com Corporate http www honeywell com International http content honeywell com global T l phone Utiliser les num ros de t l phone ci dessous pour nous contacter Organisation Num ro de t l phone tats Unis 1 800 563 2967 Honeywell Analytics 1 450 619 2450 et Canada Fax 1 888 967 9938 Honeywell Asia Pacific Inc Hong Kong Honeywell Pace Bruxelles Belgique Honeywell Int