Home
IFS MC250-4T/XXX Series User Manual
Contents
1. 3 interlogix IFS MC250 4T Series User Manual P N 1072574 REV 00 05 ISS 30JAN13 2013 UTC Fire 8 Security Americas Corporation Inc Interlogix is part of UTC Climate Controls amp Security a unit of United Technologies Corporation All rights reserved The IFS MC250 4T Series and logo are trademarks of United Technologies Other trade names used in this document may be trademarks or registered trademarks of the manufacturers or vendors of the respective products Use this product only for the purpose it was designed for refer to the data sheet and user documentation for details For the latest product information contact your local supplier or visit us online at www interiogix com UTC Fire amp Security Americas Corporation Inc 2955 Red Hill Avenue Costa Mesa CA 92626 5923 USA EU authorized manufacturing representative UTC Fire amp Security B V Kelvinstraat 7 6003 DH Weert The Netherlands CE Grass This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications You are cautioned that an
2. TX MDI MDI X Contact Media Dependant Media Dependant Interface Interface Cross 1 Tx transmit Rx receive 2 Tx transmit Rx receive 3 Rx receive Tx transmit 4 5 Not used 6 Rx receive Tx transmit 7 8 Not used IFS MC250 4T XXX Series User Manual 17 RJ45 Cable Drawing The following figure shows the pin allocation and color of a straight cable and connection of a crossover cable SIDE 4 SIDE 2 1 White Orange White Orange 2 Orange 8 Brown Cross Over Cable aioe Sver lt ame SIDE 1 412348678 1 1 White Orange 2 123456768 SIDE 2 Please make sure your connected cables are with same pin assignment and color as above picture before deploying the cables into your network 18 IFS MC250 4T XXX Series User Manual Contacting Technical Support Contact technical support if you encounter any difficulties during this installation Please make sure you have the requested diagnostic or log files ready before you contact us by phone or go to www interlogix com customer support Technical Support Europe Middle East and Africa W Select Contact Us at www utcfssecurityproducts eu North America T 1 855 286 8889 E _ techsupport interlogix com Australia E _techsupport interlogix au IFS MC250 4T XXX Series User Manual
3. XX Series User Manual 9 2 Place the wall mount plate on the rear panel of the MC250 4T 3 Assemble the wall mount plate on the MC250 4T 4 Use the hook holes at the corners of the wall mount plate to hang the MC250 4T on the wall 10 IFS MC250 4T XXX Series User Manual Installation Steps Step 1 Unpack the Industrial Fast Ethernet Switch Step 2 Check the DIN Rail is screwed on the Industrial Fast Ethernet Switch Please refer to DIN Rail Mounting section for DIN Rail installation If you want to wall mount the Industrial Fast Ethernet Switch then please refer to Wall Mount Plate Mounting section for wall mount plate installation Step 3 To hang the Industrial Fast Ethernet Switch on the DIN Rail track or wall please refer to the Mounting Installation section Step 4 Power on the Industrial Fast Ethernet Switch Please refer to the Wiring the Power Inputs section for power input The power LED on the Industrial Fast Ethernet Switch will illuminate Please refer to the LED Indicators section for meaning of LED lights Step 5 Prepare the twisted pair straight through Category 5 cable for Ethernet connection Step 6 Insert one side of Category 5 cables into the Industrial Fast Ethernet Switch Ethernet port RJ 45 port and the other side to the network devices Ethernet port RJ 45 port ex Switch PC or Server The UTP port RJ 45 LED on the Industrial Fast Ethernet Switch will illuminate when the cab
4. arning The Industrial Fast Ethernet Switch will lookup the address table for the destination address If not found this packet will be forwarded to all the other ports except the port which this packet comes in And these ports will transmit this packet to the network it is connected to If found and the destination address is located at a different port that this packet comes in the Industrial Fast Ethernet Switch will forward this packet to the port where this destination address is located according to the information from address table But if the destination address is located at the same port where this packet comes in then this packet will be filtered Store and Forward Store and Forward is one type of packet forwarding techniques A Store and Forward Industrial Switch stores the incoming frames in an internal buffer and checks for any error 12 IFS MC250 4T XXX Series User Manual from the frames before transmission No error packets occurrence it is the best choice when a network needs efficiency and stability The Industrial Fast Ethernet Switch scans the destination address from the packet header searches the routing table provided for the incoming port and forwards the packet only if required The fast forwarding makes the switch attractive for connecting servers directly to the network thereby increasing throughput and availability However the switch is most commonly used to segment existing hubs which nearly always
5. atures Complies with IEEE 802 3 IEEE 802 3u 10 100Base TX 100Base FX Supports Auto negotiation and 10 100Mbps Half Full duplex mode for each copper port High performance store and forward architecture broadcast storm control runt CRC filtering eliminates erroneous packets to optimize the network bandwidth Prevents packet loss with back pressure Half Duplex and IEEE 802 3x PAUSE frame flow control Full Duplex Backplane Switching Fabric MC250 4T 1FM 1FS 1Gbps MC250 4T 2S 1 2Gbps Integrated address look up engine support 2K absolute MAC addresses 1Mbit on chip Frame Buffer Automatic address learning and address aging CSMA CD Protocol 2 IFS MC250 4T XXX Series User Manual Industrial Case Installation 30 Metal case Protection DIN Rail and Wall Mount Design 12 to 48V DC redundant power with polarity reverse protect function and removable connector terminal block for master and slave power 40 to 75 Degree C operating temperature range Product Description The MC250 4T series are 4 Port 10 100Mbps 1 or 2 100FX Fiber Port Industrial Fast Ethernet media converters with non blocking wire speed performance and are equipped in a slim IP 30 metal endclosure for easy deployment in demanding industrial environments With a 1 1 2Gbps internal switching fabric these Industrial Fast Ethernet Switches can handle extremely large amounts of data in a s
6. ecure topology linking to a backbone or high capacity servers The Industrial Fast Ethernet Switch has 2K MAC address table and offers wire speed packets transfer performance without risk of packet loss The stable throughput of the device makes it ideal for most network environments All RJ 45 copper interfaces support 10 100Mbps Auto negotiation for optimal speed detection through RJ 45 Category 5 4 or 3 cables standard for Auto MDI MDI X that can detect the type of connection to any Ethernet device without requiring special straight or crossover cables The Flow Control function allows supported routers and servers to directly connect to the industrial media converter for fast reliable data transfer IFS MC250 4T XXX Series User Manual 3 Front Panel The figure below shows the MC250 4T 1FM 1FS and the MC250 47 2S CVT T T akeke MC250 4T 1FM MC250 4T 2S MC250 4T 1FS 4 IFS MC250 4T XXX Series User Manual indicates that power 1 has power LED Indicators Function Li Lit indicates that power 2 has power Lit indicates that either power 1 or power 2 has no power Lit indicates that the Fiber port is successfully connected to the network at 100Mbps Lit indicates that the Switch is successfully connected to the network at 100Mbps Off indicates that the Switch is successfully connected to the network at 10Mbps Lit indicates that the link throu
7. gh that port is successfully established Blink indicates that the Switch is actively sending or receiving data over that port Fiber Optical Copper Fiber Optical Copper Color Green Green Green Green Green Green LED P1 P2 FAULT 100 10 100 LNK ACT Converter Top Panel The top panel of the Industrial Media Converter consists of one terminal block connector with two DC power inputs n ao 0 6 oll 0 0 0 0 0 0 0 0 60 vv Wiring the Power Inputs The 6 contact terminal block connector on the top panel of the MC250 4T is used for two DC redundant powers inputs Please follow the steps below to insert the power wires IFS MC250 4T XXX Series User Manual 1 Insert positive negative DC power wires into the contacts 1 and 2 for POWER 1 or 5 and 6 for POWER 2 o n o o oeg 0 o 5 70 ooo O O Wve ay ve vre mu O O PWR 01 01 V2 V2 2 Tighten the wire clamp screws to prevent the wires from disconnecting Wiring the Fault Alarm Contact The fault alarm contacts are in the middle of the terminal block connector as the picture shows below Inserting the wires the MC250 4T will detect the fault status of the power failure and then forms an open circuit The following illustration shows an application example for wiring the fault ala
8. improves overall performance An Ethernet Switching can be easily configured in any Ethernet network environment to significantly boost bandwidth using conventional cabling and adapters Due to the learning function of the Industrial Fast Ethernet Switch the source address and corresponding port number of each incoming and outgoing packet are stored in a routing table This information is subsequently used to filter packets whose destination address is on the same segment as the source address This confines network traffic to its respective domain reducing the overall load on the network The Industrial Fast Ethernet Switch performs Store and Forward therefore no error packets occur More reliably it reduces the re transmission rate No packet loss will occur Auto negotiation The TP ports on the Industrial Fast Ethernet Switch have built in Auto negotiation This technology automatically sets the best possible bandwidth when a connection is established with another network device usually at Power On or Reset This is done by detecting the modes and speeds at the second of both device is connected and capable of both 10Base T and 100Base TX devices can connect with the port in either Half or Full Duplex mode IFS MC250 4T XXX Series User Manual 13 Troubleshooting This chapter contains information to help you solve issues If the Industrial Fast Ethernet Switch is not functioning properly make sure the Industrial Fas
9. ith polarity reverse protection function 9 125um fiber 13 7 Watts 46BTU DIN Rail Kit and Wall Mount Ear Store and Forward 2K entries 1Mbit Back pressure for Half duplex IEEE 802 3x Pause Frame for Full duplex 1Gbps 0 74Mpps 64Bytes IEEE 802 3 Ethernet 10Base T IEEE 802 3u Fast Ethernet 100Base TX 100Base FX IEEE 802 3x Full duplex Flow control 1EC60068 2 32 Free Fall 1EC60068 2 27 Shock 1EC60068 2 6 Vibration Port IFiber Cable lOptical Mode Distance Dimensions W x D x H eight Power Requirement Power Consumption Dissipation Installation ISwitch Specification ISwitch Processing Scheme Address Table Buffer Flow Control ISwitch Fabric Throughput Packet Per Second Standards Conformance Standards Compliance IStability testing IFS MC250 4T XXX Series User Manual 15 Operating 40 75 Degree C Storage 40 85 Degree C Operating 5 to 90 Storage 5 to 90 Non condensing FCC Part 15 Class A CE M250 4T 2S 4 x 10 100Base TX Auto negotiation Auto MDI MDI X 10Base T 2 pair UTP Cat 3 4 5 cable 100meters max 100Base TX 2 pair UTP Cat 5 5e 6 cable 100meters max 2x 100Base FX Multi Mode 50 125ym fiber 62 5 125ym fiber Single Mode 9 125um fiber Depend on SFP Module 135mm x 97mm x 32mm 4429 12 48V DC Redundant power with polarity re
10. le is connected with the network device Please refer to the LED Indicators section for LED light meaning Step 7 Insert fiber cable from the MC250 4T series to the fiber network The TX and RX or the SFP modules for MC250 4T 2S must be paired at both ends The optical port LED on the Industrial Fast Ethernet Switch will illuminate when the cable is connected to the network device Please refer to the LED Indicators section for the LED descriptions Step 8 When all connections are set and the LEDs are illuminated without any issues the installation is completed IFS MC250 4T XXX Series User Manual Switch Operation Address Table The Industrial Fast Ethernet Switch is implemented with an address table This address table is composed of many entries Each entry is used to store the address information of a node in the network including MAC address Port No and etc This information comes from the learning process of the Industrial Fast Ethernet Switch Learning When one packet comes from any port of Industrial Fast Ethernet switch the Industrial Fast Ethernet Switch will record the source address port no and the other related information in address table This information will be used to decide either forwarding or filtering for future packets Forwarding amp Filtering When one packet comes from a port of the Industrial Fast Ethernet Switch it will also check the destination address besides the source address le
11. rm contacts 6 IFS MC250 4T XXX Series User Manual Note The wire gauge for the terminal block should be in the range between 12 24 AWG The alarm relay circuit accepts up to 30V max 3A currents Mounting Installation This section describes how to mount the MC250 4T and make connections to it Please read the following sections and perform the procedures in the order presented Note In the installation steps below this Manual uses the IFS 8 Port Industrial Gigabit Switch GE DSGH 8 as an example However the steps for any IFS Industrial Switch amp Industrial Media Converter are similar IFS MC250 4T XXX Series User Manual 7 Mounting to a DIN Rail The DIN Rail kit comes assembled on the MC250 4T out of the box Please refer to following figures to hang the MC250 4T ona DIN Rail J 1 Lightly press down and push the bottom of the DIN Rail connector mount into the track 8 IFS MC250 4T XXX Series User Manual 2 Check that the DIN Rail connector mount is tightly mounted on the track 3 Please refer to following procedures to remove the MC250 4T from the track 4 Lightly press down and pull the bottom of DIN Rail connector mount to remove it from the track Mounting to a Wall To install the MC250 4T on the wall please follows the instructions described below 1 Loosen the screws to remove the DIN Rail from the Media Converter IFS MC250 4T X
12. s 5 Converter Top Panel 5 Wiring the Power Inputs 5 Wiring the Fault Alarm Contact 6 Mounting Installation 7 Installation Steps 1 Switch Operation 12 Troubleshooting 14 Specifications 15 Compatible SFP Modules 17 RJ45 Pin Assignments 7 Contacting Technical Support 19 IFS MC250 4T XXX Series User Manual Overview The Industrial Ethernet Media converter MC250 4T series fully complies with IEEE 802 3 10Base T IEEE 802 3u 100Base TX IEEE 802 3ab 1000Base T and IEEE 802 32 1000Base Sx LX the media conversion is quick and easy with simple Plug and Play installation The MC250 4T series Industrial Ethernet Media converter also supports flow control and back pressure in half duplex to eliminate packets loss Package Contents Check the contents of your package for the following parts MC250 4T series module x1 User s Manual x1 DIN Rail Kit x 1 Wall Mount Kit x 1 If any of these items are missing or damaged please contact your distributor or IFS sales rep immediately If possible retain the original carton and packaging material in case of need to return the product for repair replacement IFS MC250 4T XXX Series User Manual 1 Product Features Physical Port dal Nae Ports Fiber Optical Interface Copper Optical Mode Distance MC250 4T 1FM Tx 100Base FX Mutil mode 2km MC250 4T 1FS Single 15km ts mode MC250 4T 2S Totoo Multi 7 Single Mode TX Depends on SFP Module 2 x 100Base FX Layer 2 Fe
13. t Ethernet Switch was set up according to instructions in this manual The Link LED is not lit Solution Check the cable connection of the Industrial Fast Ethernet Switch Performance is bad Solution Check the speed duplex mode of the partner device The Industrial Fast Ethernet Switch is operating at Auto negotiation mode by default and if the partner is set to half duplex then the performance will become bad Link LED is light but the traffic is irregular Solution Check that the attached device is not set to dedicate full duplex Some devices use a physical or software switch to change duplex modes Auto negotiation may not recognize this type of full duplex setting Why does the Industrial Fast Ethernet Switch not connect to the network Solution Check every port LED on the Industrial Fast Ethernet Switch Try another port on the Industrial Fast Ethernet Switch to make sure the cable is installed properly while make sure the cable is the right type Turn off the power and turn on the power again after a while 4 IFS MC250 4T XXX Series User Manual Specifications MC250 4T 1FM MC250 4T 1FS 4 x 10 100Base TX Auto negotiation Auto MDI MDI X 10Base T 2 pair UTP Cat 3 4 5 cable 100meters max 100Base TX 2 pair UTP Cat 5 5e 6 cable 100meters max 1x 100Base FX 50 125ym fiber 62 5 125um fiber Multi mode Single mode 2km 15km 135mm x 97mm x 32mm 4369 12 48V DC Redundant power w
14. verse protection function 16 Watts 54BTU DIN Rail Kit and Wall Mount Ear Store and Forward 2K entries 1Mbit Back pressure for Half duplex IEEE 802 3x Pause Frame for Full duplex 1 2Gbps 0 89Mpps 64Bytes IFS MC250 4T XXX Series User Manual Temperature Humidity Operating Regulation Compliance Modet Hardware Specification Ports Icopper Cable Port Cable Fiber Optical Mode Distance Dimensions W x D x H jeight Power Requirement Power Consumption Dissipation linstallation Switch Specification ISwitch Processing Scheme Address Table Buffer Flow Control Switch Fabric Throughput Packet Per Second Standards Conformance 16 IEEE 802 3 Ethernet 10Base T Standards Compliance IEEE 802 3u Fast Ethernet 100Base TX 100Base FX IEEE 802 3x Full duplex Flow control 1EC60068 2 32 Free Fall Stability testing 1EC60068 2 27 Shock 1EC60068 2 6 Vibration Operating 40 75 Degree C Storage 40 85 Degree C Operating 5 to 90 Storage 5 to 90 Non condensing Regulation Compliance FCC Part 15 Class A CE Temperature Humidity Operating Compatible SFP Modules When connecting to other Ethernet equipment such as a Router Bridge Switch or Hub please refer to that device s Technical Manual RJ45 Pin Assignments 10 100Mbps 10 100Base
15. y changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment Notice This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures This Class A digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la classe A est conforme la norme NMB 003du Canada 2004 108 EC EMC Directive Hereby UTC Fire amp Security Americas Corporation Inc declares that this device is in compliance with the essential requirements and other relevant provisions of Directive 2004 108 EC 2002 96 EC WEEE directive Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union For proper recycling return this product to your local supplier upon the purchase of equivalent new equipment or dispose of it at designated collection points For more information see www recyclethis info For contact information see our Web site www interlogix com www interlogix com customer support Copyright Trademarks and patents Intended use Manufacturer Certification FCC compliance ACMA compliance Canada European Union directives 5 Contact information Contact support Contents Overview 1 Package Contents 1 Product Features 2 Product Description 3 Front Panel 4 LED Indicator
Download Pdf Manuals
Related Search
Related Contents
Epson Aculaser C1100 Cadrer le monde et l`intime Basic Instruction Manual Cooler Master X Dream i117 Kramer Electronics THGR228N User's Manual JU 東京 - アライオートオークション Samsung UD46C-B Керівництво користувача Melitta Cafina XT4 Operating Instructions (EN) Page 1 Page 2 呼 吸器外説明の ` ` ` ` ・・ 3 呼 吸器外観説明 Linksys EFVCD20 User's Manual Copyright © All rights reserved.