Home
Canopy SM User Manual Issue 3
Contents
1. Canopy can be configured to operate at a range of frequencies but at this time only channels from 5745 MHz through 5805 MHz of the 5 7 GHz product have been tested for compliance with relevant EC directives Before configuring equipment to operate outside this range please check with your regulator Exposure Note The Canopy Subscriber Module SM must be installed to provide a separation distance of at least 20 cm 7 9 in from all persons when adding the Canopy reflector dish in the 5 7 GHz band the reflector dish must be installed to provide a separation distance of at least 1 5m 59 1 in from all persons and does not emit a RF field in excess of Health Canada limits for the general population consult Safety Code 6 obtainable from Health Canada s website http www hec sc gc ca rpb In both configurations the maximum RMS power does not exceed 200mW The applicable power density exposure limit is 10 Watt m according to the FCC OET Bulletin 65 the ICNIRP guidelines and the Health Canada Safety Code 6 The corresponding compliance distances referenced above have been determined by assuming worst case scenarios The peak power density S in the far field of a radio frequency source with rms transmit power P and antenna gain G at a distance d is P G 47 d In the case of the Canopy SM without reflector the gain is 8 dBi a factor of 6 3 so the peak power density equals the exposure limit at a distance of 10 cm A f
2. pin 1 white orange pin 2 white green pin 3 white blue pin 4 green solder to orange pin 5 blue pin 6 orange solder to green e Insert default plug in the GPS sync port of the module and apply power to the module via its Ethernet cable When the module is booted up power applied it will be in default mode where the IP address will be 169 254 1 1 and the passwords will be blank All other configurations will have been preserved EVENT LOG 3 Canopy Home Page Microsoft Internet Explorer alelxi Be ER yew Fortes Tools teb tak gt DD Deh afos peor LD aOR Agress fE rerz 51192 93 18 42 z Pu juts CANOPY State 01 45 18 UT 01 04 00 Fie CASIPPC prappc 250 brpa devices wtisp syalog c Line 492 System Log Cleared Config mem sent Log TAPE Data Ee O ionet Astor BET D Icono Homne Page SEMIABLODLS 10m This page contains information that is recorded from the subscriber module for troubleshooting purposes Please make note of the information that is gathered here when calling for technical support Clear Event Log this button will clear the event log AP EVAL DATA The AP Eval Data web page contains information on each of the access point modules that the subscriber module has visibility to For each access point module that can be seen certain bits of information are shown on this web page An example of the information shown on this web page for eac
3. Device Type displays the type of Canopy module that is currently being viewed This field will let the operator know the frequency band of the module the protocol that it is utilizing and the MAC address of the module The frequency band can either be in the 5 2 GHz or 5 7 GHz band The protocol for a subscriber module is multipoint The MAC address will be in the following format Oa 00 38e xx xX XX Software Version displays the version of the software that is currently loaded into the module Please make note of this information when obtaining technical support FPGA Version displays the version of the FPGA field programmable gate array that is currently loaded into the module Please make note of this information when obtaining technical support Uptime displays the length of time the module has been operating since a rest of the module occurred System Time displays the current time which is inherited from the Canopy System via the registration to an access point module When the module is registered to a Canopy System where a Cluster Management Module CMM is being utilized the time is displayed in Greenwich Mean Time GMT Ethernet Interface displays the configuration of the Ethernet interface on the module Session Status displays the current session state the module is in There are five 5 options that will display in this field scanning syncing registering registered and alignment e Scanning module is cycl
4. Q MOTOROLA Canopy Subscriber Module USER MANUAL SM02 UM en Issue 3 October 2003 O 2003 Motorola Inc All rights reserved Printed in the U S A NOTICES Important Note on Modifications Intentional or unintentional changes or modifications to the equipment must not be made unless under the express consent of the party responsible for compliance Any such modifications could void the user s authority to operate the equipment and will void the manufacturer s warranty U S Federal Communication Commision FCC and Industry Canada IC Notification This device complies with part 15 of the U S FCC Rules and Regulations and with RSS 210 of Industry Canada Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation In Canada users should be cautioned to take note that high power radars are allocated as primary users meaning they have priority of 5250 5350 MHz and 5650 5850 MHz and these radars could cause interference and or damage to license exempt local area networks LELAN This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the U S FCC Rules and with RSS 210 of Industry Canada These limits are designed to provide reasonable protection against harmful interference in a residential installa
5. 18 Branding sss cca ites ots ea ek ei ae Le a ee ee ee ds 19 THE INTERFACE SCREENS i ssssssssieniseiiieniansinuniansdnvreeenins anesinunenenene anual 20 Stat s Page ina o ee 20 A A O 22 Event Log ias 25 AP Eval Data ar nourn oti ibe noida a oe abode aa Arad 26 Ethernet Stats EE RS acest seetvaaetecoea mused 27 Expanded Sie i Ee E E E 28 LINK NN 28 AMOO MN Er a A Aa 29 BER DisSpla sprotna eumee a a Ea TaT aT TR iana 30 ACCESSORIES a aaa 31 APPENDIX iii 32 SPECIFICATIONS unan daa 33 SM User Manual Issue 3 Page 6 of 33 GETTING STARTED WELCOME Congratulations on the purchase of the Canopy subscriber module from Motorola The Canopy subscriber module is the latest innovation in high speed wireless networking that lets you easily network at high speeds FEATURES The following is a subset of features included with your Canopy subscriber module Broadband network speeds Small compact design No special setup on your PC INTENDED USE This manual is intended to be used with Canopy software release version 3 x or greater The intended audience for this manual is system operators and equipment installers Additional information on new features in new releases is available in the Canopy Software Release Notes available on the Canopy web site at http www motorola com canopy DOCUMENT CHANGE HISTORY New in Issue 3 e AES product described along with DES product e 5 7 GHz ISM supports 6 channels up from 4 with
6. 5 7 GHz U NII e 5 7 GHz ISM frequencies approved for use in Canada as well as US e MAC addresses of older non autosensing modules are listed non autosensing modules require correct choice of straight through vs crossover cables New in Issue 2 e Updated Notices section including European Community Notification RF Exposure Note and Software License Terms and Conditions e Measurement units internationalized with metric as well as English units e Updates for new hardware features Currently shipping modules now auto sense the Ethernet termination either a straight thru or crossover RJ 45 cable can be used to connect to either a network interface card or hub switch or router e Specifications changed to reflect expanded lower temperature limit of 40 F 40 C for all equipment PRODUCT DESCRIPTION Canopy Subscriber Module The base cover of your Canopy subscriber module is easily removed by depressing the release lever on the back of the cover SM User Manual Issue 3 Page 7 of 33 Base Cover Base Cover Release Ethernet Lever Cable FIGURE 1 Remove the base cover as shown in FIGURE 1 to access the Ethernet connection and to view the LED indicators e The RJ 45 connector is used to attach the Ethernet cable e The LED s indicate system status and can be used for alignment RJ45 E Connection Connector 7 _ Base Cover Ethernet Cable FIGURE 2 SM User Manual Issue 3 Page 8 of 33 The Conn
7. NOT SM User Manual Issue 3 Page 3 of 33 LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT MOTOROLA DOES NOT WARRANT THAT THE OPERATION OF THE SOFTWARE WILL BE UNINTERRUPTED OR ERROR FREE OR THAT DEFECTS IN THE SOFTWARE WILL BE CORRECTED NO ORAL OR WRITTEN REPRESENTATIONS MADE BY MOTOROLA OR AN AGENT THEREOF SHALL CREATE A WARRANTY OR IN ANY WAY INCREASE THE SCOPE OF THIS WARRANTY MOTOROLA DOES NOT WARRANT ANY SOFTWARE THAT HAS BEEN OPERATED IN EXCESS OF SPECIFICATIONS DAMAGED MISUSED NEGLECTED OR IMPROPERLY INSTALLED BECAUSE SOME JURISDICTIONS DO NOT ALLOW THE EXCLUSION OR LIMITATION OF IMPLIED WARRANTIES THE ABOVE LIMITATIONS MAY NOT APPLY TO YOU Limitation of Remedies and Damages Regardless of whether any remedy set forth herein fails of its essential purpose IN NO EVENT SHALL MOTOROLA OR ANY OF THE LICENSORS DIRECTORS OFFICERS EMPLOYEES OR AFFILIATES OF THE FOREGOING BE LIABLE TO YOU FOR ANY CONSEQUENTIAL INCIDENTAL INDIRECT SPECIAL OR SIMILAR DAMAGES WHATSOEVER including without limitation damages for loss of business profits business interruption loss of business information and the like whether foreseeable or unforeseeable arising out of the use or inability to use the Software or accompanying written materials regardless of the basis of the claim and even if Motorola or a Motorola representative has been advised of the possibility of such damage Motorola s lia
8. Service Names MOTOROLA the stylized M Logo and all other trademarks indicated as such herein are trademarks of Motorola Inc Reg U S Pat amp Tm Office Canopy is a trademark of Motorola Inc All other product or service names are the property of their respective owners Motorola Inc Broadband Wireless Technology Center 50 East Commerce Drive Schaumburg IL 60173 USA http Awww motorola com canopy SM User Manual Issue 3 Page 5 of 33 TABLE OF CONTENTS GETTING STARTED socias 7 Welcome sio ia 7 FOatures a a be Sa a ee ee ee a at 7 Intended USO casta A it 7 Document Change Hist Visio a 7 PRODUCT DESCRIPTION 004 cbratwedeactued sbosodebectued boctondsbedioueebudine 7 Canopy Subscriber Module coooooocccccccccocccccncncnnnnnnnnnnnnnnnnnnnononnnnnonononnnnnnn nana 7 BACKGROUND INFORMATION on NETWORKING ccccccccccccccccccccccccccccnnnnnnnos 10 INSTALLATION anar 11 Unpack the Canopy Products 0 ccccccceecceeeeeeeeeeeeeeeeeeaeeeeeeeeeeeeeeeaaaaaeeeeeeseeeeseneeeees 11 Configuring the Subscriber Module cocos ii 11 Installation of the Subscriber Module oocccccccccccnncnonnnnnnnnnnnnnnnnnennnnnnenenenenennnnnenennnnnnn 12 Align the Subscriber Module cimas iii is dia so 14 CABINA een 16 ADVANCED FEA TURES cicle dcialeadciaiada 18 Security DES Encryption 23 2ci3 2 ecect ace aden ae ease cea seci acetals ce soe Ube Bedadeacdccseesi taceseee ieee 18 Security AES ENCINA tera ate nai hs
9. There are two modes available the first is Alignment mode and the second is Operational mode See Alignment section for more information Operational Mode is the default setting Bridge Timeout Entry choose the appropriate bridge timeout for correct network operation with existing network infrastructure Authorization Key each module ships with a unique pre programmed authorization key that is to be utilized when an operator configures the Canopy System for DES encryption of the over the air link The default key is permanently stored on the module Site Name enter information relating to a name given to the physical module This parameter will set the supplied information into the sysName SNMP MIB II object and can be polled by a SNMP management server The buffer size for this field is 128 characters Site Contact enter contact information relating to the module This parameter will set the supplied information into the sysContact SNMP MIB II object and can be polled by a SNMP management server The buffer size for this field is 128 characters Site Location enter information relating to the physical location of the module This parameter will set the supplied information into the sysLocation SNMP MIB II object and can be polled by a SNMP management server The buffer size for this field is 128 characters Save Changes by clicking on this button any changes that have been made on the Configuration page will be committed to flash memor
10. an access point module The color codes must match The operator can prevent unauthorized users from connecting to the subscriber module s web based interface by assigning a password There is no default password and password protection is turned off from the factory Passwords can be from 1 to 16 characters Any combination of characters is allowed except for these special characters NOTE If the operator forgets either the password or the IP address for the subscriber module a Canopy default plug can be used to regain access See Configuration section for information on default plug There are two types of passwords that can be configured display only or full access The display only password allows the operator to view the module s current status The full access password allows the operator to view the module s current status and change its configuration By viewing the red lettering to the right of the entry fields the operator can SM User Manual Issue 3 Page 11 of 33 discern that a password is set e The operator can enter in information about the Site Name Location and Contact This is optional If the subscriber module is in the 5 7 GHz band and the operator will be using the Canopy passive reflector to obtain a link at distances of 10 miles or less the subscriber module should be mounted to the reflector in the following manner The reflector arm is molded to receive the plastic housing of the
11. part of the host address How does data know where it is supposed to go IP systems developed a unique form of logic to make this determination Class A network addresses always have the first bit of their IP address set to O Class B network addresses always have their first bit set to 1 and their second bit set to 0 Class C network addresses always have their first two bits set to 1 and the third bit set to 0 By examining these first bits of the IP address a device can determine what subnet mask should be applied to the IP address and determine where to route the data The following is a synopsis of an Internet Draft http www ietf org internet drafts draft ietf zeroconf ipv4 linklocal 05 txt that describes how Microsoft and Apple operating systems react when a DHCP server is not found on the network In general a computer needs certain configuration information to operate on a network Those configurations are an IP address a subnet mask and possibly a gateway address A DHCP server will automatically assign this configuration information to a computer on a network or an operator is required to manually input these configurable items When a computer is brought online and a DHCP server is not accessible i e server is down or the computer is not plugged into the network Microsoft and Apple operating systems will default to an IP address and subnet mask of 169 254 x x and 255 255 0 0 169 254 16 SPECIFICATIONS Operating Frequen
12. seeing The colors of the LEDS have no particular meaning other than to assist is distinguishing one position from the next The minimum values that are needed for an acceptable link are RSSI this above 700 Jitter that is between 5 and 9 and link efficiencies that are greater than 90 in both the up and down link If any one of these criteria are not met the link may still be operational but may have issues time to time If a Canopy module is placed into Alignment Mode it will automatically drop into Operational Mode after 15 minutes BER Display aleja Fie Edt yew Favertes Tools Hep pod gt DIA Qe apote Gro DORA Adress E ner 1192 93 16 61 ew hs e o CANOPY O Sams 7 Receive BER Results Configuration Number of bits received 141824 Event Log Number of Primary bit errors TAP Eval Date Number of Secondary ba errors 0 Heras Measured Ba Error Rate 0 000000e 00 Link Test Retresh Display Alignment BER Display HIP Stats SM Syne Log SMSesLog zal RESYNC Log RESCAN Log TRECAL Log eee 8 Done MD ont Asa WS ED gt El comer tome Page SSEBSMALODH zsm Bit Error Rate BER Display is utilized by the operator to measure the amount bit errors present in a link BER Display will only work if the access point module is configured to send the BER stream IMPORTANT If one access point module in a cluster is set to send a BER stream then all other access point modules in that cluster mus
13. tail from the AC adapter into the subscriber module See following wiring diagram SM User Manual Issue 3 Page 13 of 33 Wiring Diagram of Canopy subscriber module to Computer with Surge Suppressor outside wall Ethernet cable Ethernet cable N 300SS lt Ln lt to NIC_ 24 VDC to Canopy gt gt Y Computer wall adapter _ 10AWG 7 CU wire grounding system ALIGN THE SUBSCRIBER MODULE There are two methods that can be utilized for aligning a subscriber module to an access point module The first is to monitor the RSSI and Jitter values on the subscriber The second is to utilize the built in alignment tool on the subscriber module In either case it is necessary for a computer to be connected to the subscriber module to gain access to the web based interface Monitoring RSSI and Jitter The RSSI received signal strength indicator and Jitter are two parameters that can be used for alignment of a subscriber module The RSSI level must be above 700 and the Jitter must be 9 or below with 5 being the best for a link to be acceptable e Point subscriber module in direction of the access point Remember that when utilizing the internal patch antenna the energy is radiated out in a 60 horizontal by 60 vertical pattern HS IF UTILIZING A 5 7 GHz SUBSCRIBER MODULE the passive reflector will NES change the radiated pattern to 6 horizontal by 6 vertical e The module has a s
14. will now run for the set duration If the web page is not set to automatically refresh click the Refresh Display button to see the results For a Canopy System link to be considered acceptable it is necessary for the efficiencies of the link test to be greater than 90 in both the uplink and downlink direction It is recommended that when a new link is installed that a link test be executed to ensure that the efficiencies are within recommended guidelines The key fields are Downlink RATE bits per second e Uplink RATE bits per second e Downlink Efficiency percent e Uplink Efficiency percent Alignment 3 Canopy Home Page Microsoft Internet Explorer slej x Ee Es yew Favores Toor Heb 1 pid e y O AA Qe aportes petor Ty GR SOR aAa Or Configuration SM is in Operating Mode AP Eral Data as hemer State sis Link Test Users BER Display RSS Only Mode C Eny HIP Stats RF Carrier Frequency Wire 045 sR Kodar bus SMSesLog Enable Aining Mode Disable Aiming Mode _ RESYNGTAS 8 bone O ima stort SO 9 E coopy Home Page LIEBOMDIODA 1213m The Alignment web page contains tools to assist in the alignment of a subscriber module to an access point module There are two modes that can be utilized when aligning a module 1 RSSI only and 2 normal alignment mode RSSI Only is a mode where the module will report the signal strength based on the amount of energy present at a selected freque
15. ating frequencies which are not harmonized through the EC All licenses must be obtained before using the product in any EC country Declaration of conformity Motorola declares the GHz radio types listed below comply with the essential requirements and other relevant provisions of Directive1999 5 EC Relevant Specification EN 301 893 or similar radio spectrum EN301489 17 EMC EN60950 safety ceO Product Details for Products Tested for Compliance with Relevant EC Directives Module Type Band Maximum Effective Isotropic Modulation Type Operating Channels Non Frequency Transmitter Radiated Power overlapping Range Power EIRP Channel Spacing Access Point 5 725 to 5 825 200mW RMS 1 Watt EIRP High Index 2 level 5745 to 5805 MHzin 20 MHz GHz FSK 5 MHz increments Subscriber 5 725 to 5 825 200mW RMS 1 Watt EIRP High Index 2 level 5745 to 5805 MHzin 20 MHz Module GHz FSK 5 MHz increments Subscriber 5 725 to 5 825 200mW RMS 63 Watts EIRP High Index 2 level 5745 to 5805 MHz in 20 MHz Module with GHz FSK 5 MHz increments Reflector Backhaul 5 725 to 5 825 200mW RMS 1 Watt EIRP High Index 2 level 5745 to 5805 MHzin 20 MHz GHz or 4 level FSK 5 MHz increments SM User Manual Issue 3 Page 2 of 33 Backhaul with 5 725 to 5 825 200mW RMS 63 Watts EIRP High Index 2 level 5745 to 5805 MHzin 20 MHz Reflector GHz or 4 level FSK 5 MHz increments
16. bility to you for direct damages for any cause whatsoever regardless of the basis of the form of the action will be limited to the price paid for the Software that caused the damages THIS LIMITATION WILL NOT APPLY IN CASE OF PERSONAL INJURY ONLY WHERE AND TO THE EXTENT THAT APPLICABLE LAW REQUIRES SUCH LIABILITY BECAUSE SOME JURISDICTIONS DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES THE ABOVE LIMITATION MAY NOT APPLY TO YOU Maintenance and Support Motorola shall not be responsible for maintenance or support of the software By accepting the license granted under this agreement you agree that Motorola will be under no obligation to provide any support maintenance or service in connection with the Software or any application developed by you Any maintenance and support of the Related Product will be provided under the terms of the agreement for the Related Product Transfer In the case of software designed to operate on Motorola equipment you may not transfer the Software to another party except 1 if you are an end user when you are transferring the Software together with the Motorola equipment on which it operates or 2 if you are a Motorola licensed distributor when you are transferring the Software either together with such Motorola equipment or are transferring the Software as a licensed duly paid for upgrade update patch new release enhancement or replacement of a prior version of the S
17. bscriber is currently registered to Session Count displays the number of times the subscriber module has gone in and out of session with the access point If this number is particularly large it typically signifies that there is some sort of issue with the link i e non line of sight interferers etc Out of Range displays a counter for the number of times the access point module has seen a subscriber module who has attempted to register and has been farther away than the max range parameter on the access point Sector ID displays the sector ID of the access point module Color Code displays the color code of the access point module Sector User Count displays the numbers of registered subscriber modules on the access point module Rescan APs click on this button to force the subscriber module to redo the scanning process The subscriber module will scan through the frequencies checked on the Configuration web page for all available access point modules and register to the one that provides the best results for RSSI Jitter and number of registered users ETHERNET STATS The Ethernet Stats web page reports TCP throughput and error information for the Ethernet connection of the subscriber module The following definitions are available inoctets count displays the total number of octets received on the interface including framing characters inucastpkts count displays the total number of subnetwork unicast packets delivered
18. cy Range U NII 5 25 to 5 35 GHz and 5 725 to 5 825 GHz ISM 5 725 to 5 850 GHz Access Method TDD TDMA Signaling Rate 10 Mbps Modulation Type High Index 2 level Frequency Shift Keying FSK Optimized for interference rejection Carrier to Interference C I also known as Jitter 3dB nominal Receiver Sensitivity 83dBm 10 BER Operating Range All Weather Up to 2 3 6 km miles with integrated antenna in the 5 2 GHz band Up to 10 mile 16 km with passive reflector in the 5 7 GHz band Transmitter Power Meets FCC U NII ISM and IC LELAN ERP Limit DC Power measured at DC converter 0 3A 24 VDC 7 2 watts typical Interface 10 100 BaseT half full duplex Rate auto negotiated 802 3 compliant Protocols Used by Canopy IPV4 UDP TCP ICMP Telnet HTTP FTP SNMPv2c DES Protocols Supported by Canopy Switched Layer 2 Transport with support for all common Ethernet protocols including IPV6 NetBIOS DHCP IPX etc Software Upgrade Path Remotely downloaded into FLASH via RF link Network Management HTTP TELNET FTP SNMP Temperature 40 C to 55 C 40 F to 131 F Dimensions 11 75 H x 3 4 W x 3 4 D 29 9 cm H x 8 6 cm W x 8 6 cm D Weight 1 Ib 45kg
19. d Password a Password No Password Full Access a a Password Webpage Auto Update Seconds 0 Disable Auto Update SM Power Up Mode Power up im Aim Mode With No 802 3 Lak Power up in Operational Mode Bridge Entry Timeout Minutes Range 25 1440 Minutes a Use Defuse Key Authonzation Rey Use This Key p Site Information zi a D ienet Ms HG D E Canopy Home Page SSL BIMAZODSH 212m The Configuration webpage contains information and configurable parameters pertaining to the operation of the product The first line of information on the Configuration screen is a repeat of the Device Type from the Status web page The following are the parameters and their descriptions Link Negotiation Speeds choose the type of link speed desired for the Ethernet connection The default for this parameter is for all the choices to be checked Custom RF Frequency Scan Selection SM List choose the frequencies that the subscriber module will scan when looking for access point modules The default for this parameter is to scan all available frequencies LAN1 IP enter in the IP address that will be associated with the Ethernet connection on this module The default address is 169 254 1 1 The radio buttons to the right of the IP address field offer the ability to make the LAN 1 IP either a local or publicly accessible address If the address is designated a local address it will only be accessible via the host c
20. ddresses are 32 bit binary numbers that have two corresponding parts or sub addresses the first part identifying the network and the second part identifying the hosts on the network An imaginary boundary separates the first part from the second This imaginary boundary is marked by way of the subnet mask The subnet mask is another 32 bit binary number the acts like a filter on the IP address When a subnet mask has a bit set to 1 the corresponding bit in the IP address is part of the network address A subnet is classified as either a class A class B or class C network The following table shows the common subnet mask classes Class Network Portion Host Portion A 11111111 00000000 00000000 00000000 B 11111111 11111111 00000000 00000000 C 11111111 11111111 11111111 00000000 For example if you have an IP address of 169 254 1 1 and a subnet mask of 255 255 0 0 then the first 16 bits of the 32 bit IP address identify the network 10101001 11111110 00000001 00000001 IP address 11111111 11111111 00000000 00000000 Subnet Mask There are 2 65 536 addressable hosts in this example and 169 254 is the network There is one last piece of information that is needed here Subnet masks are not shipped around in the IP packet the packet only contains the 32 bit IP address of the destination So without this valuable piece of information devices have no idea what portion of the IP address is part of the network and which is
21. e software and the same features will be available for AES products DES backhauls are available in both 10 Mbps and 20 Mbps signaling rates AES backhauls are only available with a 10 Mbps signaling rate Canopy DES products are not upgradeable to AES To have the option of AES encryption you must purchase AES products Canopy AES products use a different FPGA load than DES products However the FPGA will be upgraded as needed to provide new features or services similar to the DES products The same as with DES encryption of the over the air link is enabled or disabled per Access Point module or per Backhaul timing master module The Canopy modules contain unique factory programmed secret keys to establish the encrypted link If an authentication key must be the same key on each end of the backhaul link has been entered using the Backhaul Configuration page then that key is also used to establish the AES encryption key Canopy AES products and DES products do not interoperate when enabled for encryption as DES and AES are different encryption schemes An AES AP with encryption enabled can only communicate with AES SMs and similarly an AES Backhaul timing master module with encryption enabled can only communicate with an AES Backhaul timing slave module However if encryption is disabled AES modules can communicate with DES modules BRANDING On each Canopy module the web based interface screens have a Canopy logo that can be rep
22. ection LEDs report information about the current status of the subscriber module The following descriptions explain the function of each LED Operational Mode When looking at the LEDs on the module the following descriptions go from left to right LNK The link LED displays the status of the Ethernet link to the Canopy module The LED will be constantly lit if there is an Ethernet link present The LED is colored green ACT 4 The activity LED displays the status of any data activity on the Ethernet link The LED will flash at no particular speed when data is being transferred on the Ethernet link The LED is colored orange GPS 3 This LED is not used on the subscriber module SES 2 The session LED displays status of whether or not a subscriber module is in session registered The LED will be constantly lit if the unit is in session The LED is green SYN 1 The sync LED displays sync status In short this LED will be lit if the unit is in session i e registered SES 2 LED is lit The operator should minimize any flicker in this LED The LED is orange PWR The power LED displays the status of power to the module The LED will be constantly lit if power is applied correctly The LED is red When the subscriber module is not registered to an access point module the SYN 1 SES 2 and GPS 3 LEDs will cycle on and off from left to right Alignment Mode When a subscriber module is placed in Alignment Mode the LEDs take on an
23. ed One possible reason for discarding such a packet could be to free up buffer space outerrrors count displays the total number of outbound packets that could not be transmitted because of errors RxBabErr displays the total number of receiver babble errors EthBusErr displays the total number of Ethernet bus errors on the Ethernet controller CRCError displays the total number of CRC errors on the Ethernet controller RxOverrun displays the total number of receiver overrun errors on the Ethernet controller Late Collision displays the total number of late collisions on the Ethernet controller A normal collision occurs during the first 512 bits of the frame transmission If a collision occurs after the 512 bit times then it is considered a late collision A late collision should be taken as a serious network problem since it causes the frame being transmitted to be discarded The most common cause of late collisions is a mismatch between duplex configurations at each end of a link segment RetransLimitExp displays the total number of retransmit limit expirations TxUnderrun displays the total number of transmission underrun errors on the Ethernet controller CarSenseLost displays the total number of carrier sense lost errors occurred on the Ethernet controller EXPANDED STATS When clicking on the Expanded Stats button and then clicking on one of the standard web page i e Status or Configuration more fields may be displayed o
24. entirely different purpose The power LED will still indicate whether or not power is applied to the module The 6 LEDs and are turned into a 6 position bar graph The more LEDs that are lit the better the RSSI and Jitter values the module is seeing The colors of the LEDS have no particular meaning other than to assist is distinguishing one position from the next See Alignment section for more information on alignment mode SM User Manual Issue 3 Page 9 of 33 BACKGROUND INFORMATION ON NETWORKING Computers are assigned IP addresses by network operators which have two methods available static or dynamic IP addressing The user of this document will need to understand how IP addressing is done at their particular location All Canopy radio products Subscriber Modules Access Point Modules and Backhaul Modules have the default IP address of 169 254 1 1 For a computer to talk to Canopy as it comes from the factory either of the following conditions must be met e If the computer is not configured for DHCP then it has to have a static IP address on the 169 254 network i e 169 254 1 5 e If the computer is configured for DHCP then it will automatically obtain an IP address on the 169 254 network after minute or two as long as it is not connected to the network SM User Manual Issue 3 Page 10 of 33 INSTALLATION The following steps are required to install the Canopy subscriber module Unpack the Canopy products Configure the sub
25. eries of states that it will go through to register to an access point Those states are scanning syncing registering and registered RSSI and Jitter will not report on the web page till the unit is registered If the module will not register ensure that there is line of sight the access point module is transmitting the color codes match and that the subscriber is within the appropriate distance to the access point as specified by the max range value on the access point module e After the module has registered slowly adjust the positioning of the subscriber module until RSSI has been maximized and Jitter has been minimized Lock down the module when appropriate e Perform a link test to check the efficiency of the link See Link Test for further information The efficiencies must be above 90 in both the up and down link for packet loss to not occur Utilizing Alignment Mode The Alignment web page will display in graphical form levels for RSSI Jitter and the number of registered users at the access point SM User Manual Issue 3 Page 14 of 33 e Point subscriber module in direction of the access point Remember that when utilizing the internal patch antenna the energy is radiated out in a 60 horizontal by 60 vertical pattern HS IF UTILIZING A 5 7 GHz SUBSCRIBER MODULE the passive reflector will NES change the radiated pattern to 6 horizontal by 6 vertical e Set the web page to auto refresh see Configuration section for f
26. h access point module Index 0 Frequency 0 MHz ESN 0a 00 3e 00 01 d5 Jitter 5 RSSI 1295 Beacon Count 37 Type Multipoint Avail 1 Age 0 Lockout 0 RegFail 0 Range 245 feet TxBER 1 Session Count 3 No LUIDS 0 Out of Range 0 Rescan Req 0 FrameNumber 568 SectorID 0 Color Code 0 BeaconVersion 1 SectorUserCount 1 PercentDataDwn 75 PercentDataUpHi 0 NumDAckSlots 3 NumContSlots 3 NumUAckSlots 3 Descriptions of the parameters that can be useful for managing and troubleshooting a Canopy System are Index each access point module that a subscriber module can see is assigned an index value for purposes of this web page only The index number starts with O and increases by 1 This index is used to tell the operator which access point module the subscriber is currently registered to For example the first line of text on the web page says Current entry index 5 the operator would then scroll down the list of access point modules to the module with ndex 5 to view information about the link Frequency displays the transmit frequency of the access point module ESN displays the electronic serial number MAC address of the access point module Jitter displays the last jitter value captured between the subscriber and access point module Range displays the distance in feet between the subscriber and access point module This parameter will only be valid when observing the data for the access point module that the su
27. in valid unless such invalidity would frustrate the purpose of our agreement The failure of either party to enforce any rights granted hereunder or to take action against the other party in the event of any breach hereunder shall not be deemed a waiver by that party as to subsequent enforcement of rights or subsequent action in the event of future breaches Hardware Warranty in U S Motorola U S offers a warranty covering a period of 90 days from the date of purchase by the customer If a product is found defective during the warranty period Motorola will repair or replace the product with the same or a similar model which may be a reconditioned unit without charge for parts or labor IN NO EVENT SHALL MOTOROLA BE LIABLE TO YOU OR ANY OTHER PARTY FOR ANY DIRECT INDIRECT SM User Manual Issue 3 Page 4 of 33 GENERAL SPECIAL INCIDENTAL CONSEQUENTIAL EXEMPLARY OR OTHER DAMAGE ARISING OUT OF THE USE OR INABILITY TO USE THE PRODUCT INCLUDING WITHOUT LIMITATION DAMAGES FOR LOSS OF BUSINESS PROFITS BUSINESS INTERRUPTION LOSS OF BUSINESS INFORMATION OR ANY OTHER PECUNIARY LOSS OR FROM ANY BREACH OF WARRANTY EVEN IF MOTOROLA HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES Some states do not allow the exclusion or limitation of incidental or consequential damages so the above exclusion or limitation may not apply to you IN NO CASE SHALL MOTOROLA S LIABILITY EXCEED THE AMOUNT YOU PAID FOR THE PRODUCT Trademarks Product Names and
28. ing through the RF frequencies that it is configured to scan and looking for an access point module Syncing module is attempting to synchronize timing to a single access point module e Registering module sent a request for registration and is awaiting a response e Registered module is locked on to a specific access point module and ready to transmit and receive data packets Alignment module is in alignment mode RSSI displays the current value for the Radio Signal Strength Indicator This parameter will only display information when the module is registered to an access point module and the value is only updated by either refreshing the web browser screen or configuring the Canopy module to auto refresh see Configuration web page An acceptable RSSI value for a registered link is greater than 700 however it is important to view this value in conjunction with the Jitter value Jitter displays the current value for the quality of the received signal This parameter will only display information when the module is registered to an access point module and the value is only updated by either refreshing the web browser screen or configuring the Canopy module to auto refresh see Configuration web page The value range for Jitter is 5 15 with the quality being better on the low end of the scale Jitter must be below 9 for a link to be of acceptable quality Air Delay display the distance from the subscriber module to the registe
29. is enabled or disabled per Access Point module or per Backhaul timing master module The Canopy modules contain unique factory programmed secret keys to establish the encrypted link If an authentication key must be the same key on each end of the backhaul link has been entered using the Backhaul Configuration page then that key is also used to establish the DES encryption key Encryption does not affect the performance or throughput of the system SECURITY AES ENCRYPTION Motorola also offers Canopy products that provide Advanced Encryption Standard AES encryption Like DES AES is a secret key encryption scheme but AES uses the Rijndael algorithm and 128 bit keys to establish a higher level of security than DES Due to the level of security provided by AES the US government has established export controls on communications products that use AES These export controls may mean that outside of the US AES products are only available in certain regions check with your Canopy distributor or reseller for availability in your area Canopy AES products run the same software as DES products so the features available are exactly the same and work the same with the only exception being that the AES products provide AES instead of DES encryption when enabled for encryption on the Configuration screen All the interface screens Status pages Configuration pages etc are identical As new software features become available on DES products the sam
30. laced with an operator s company logo The Canopy logo file is called canopy jpg and the replacement file must also be called canopy jpg The new file is transferred via FTP to the module and then added to a special filesystem through a telnet session The following command can be used during a telnet session e addwebfile add a custom logo file to the filesystem e clearwebfile clear the customer logo file from the filesystem e Isweb list the custom logo file and display the storage space available on the filesystem The following is a sample FTP session gt ftp 169 254 1 1 Connected to 169 254 1 1 220 FTP server ready Name 169 254 1 1 none root 331 Guest login ok Password lt password if configured gt 230 Guest login ok access restrictions apply ftp gt binary 200 Type set to I ftp gt put canopy jpg ftp gt quit 221 Goodbye The following is a sample telnet session Motorola Broadband Wireless Technology Center Copyright 2001 2002 Motorola Inc Login root Password lt password if configured gt Telnet gt lsweb Flash Web files free directory entries 32 free file space 64336 bytes Telnet gt addwebfile canopy jpg Telnet gt lsweb Flash Web files canopy jpg 7867 free directory entries 31 free file space 56468 Telnet gt clearwebfile Telnet gt lsweb Flash Web files free directory entries 32 free file space 64336 bytes THE INTERFACE SCREENS The Canopy subscribe
31. le law Termination This License is effective until terminated This License will terminate immediately without notice from Motorola or judicial resolution if you fail to comply with any provision of this License Upon such termination you must destroy the Software all accompanying written materials and all copies thereof and the sections entitled Limited Warranty Limitation of Remedies and Damages and General will survive any termination Limited Warranty Motorola warrants for a period of ninety 90 days from Motorola s or its customer s shipment of the Software to you that i the disk s on which the Software is recorded will be free from defects in materials and workmanship under normal use and ii the Software under normal use will perform substantially in accordance with Motorola s published specifications for that release level of the Software The written materials are provided AS IS and without warranty of any kind Motorola s entire liability and your sole and exclusive remedy for any breach of the foregoing limited warranty will be at Motorola s option replacement of the disk s provision of downloadable patch or replacement code or refund of the unused portion of your bargained for contractual benefit up to the amount paid for this Software License THIS LIMITED WARRANTY IS THE ONLY WARRANTY PROVIDED BY MOTOROLA AND MOTOROLA AND ITS LICENSORS EXPRESSLY DISCLAIM ALL OTHER WARRANTIES EITHER EXPRESS OF IMPLIED INCLUDING BUT
32. lows Grant of License Subject to the following terms and conditions Motorola Inc grants to you a personal revocable non assignable non transferable non exclusive and limited license to use on a single piece of equipment only one copy of the software contained on this disk which may have been pre loaded on the equipment Software You may make two copies of the Software but only for backup archival or disaster recovery purposes On any copy you make of the Software you must reproduce and include the copyright and other proprietary rights notice contained on the copy we have furnished you of the Software Ownership Motorola or its supplier retains all title ownership and intellectual property rights to the Software and any copies including translations compilations derivative works including images partial copies and portions of updated works The Software is Motorola s or its supplier s confidential proprietary information This Software License Agreement does not convey to you any interest in or to the Software but only a limited right of use You agree not to disclose it or make it available to anyone without Motorola s written authorization You will exercise no less than reasonable care to protect the Software from unauthorized disclosure You agree not to disassemble decompile or reverse engineer or create derivative works of the Software except and only to the extent that such activity is expressly permitted by applicab
33. lt pin 1 Tei QU oR pin2 gt orange lt pin 2 2 ae pin3 white green lt pin 3 Bets PE pin4 blue lt pin 4 pin5 gt white blue lt pin5 w n A pin6 green lt pin 6 5 pin 7 white brown lt pin 7 RX 6 E 6 TX pin8 gt brown lt pin 8 wv p gt 7 y return l N A return Pins 4 5 7 and 8 are used to carry power to the Canopy modules SM User Manual Issue 3 Page 16 of 33 RJ 45 Crossover Pin RJ 45 Crossover Pin pini gt white orange lt pin 3 TX 1 gt 3 RX pin2 gt orange lt pin 6 TX 21 6 RX pin 3 white green pin 1 Baa ipa pin4 blue lt pin 4 pin5 gt white blue lt pin5 ee av pin6 green lt pin 2 ee n pin 7 white brown lt pin 7 RX m 2 TX pin8g8 brown lt pin 8 av j S ANS i return return CDE 8 Pins 4 5 7 and 8 are used to carry power to the Canopy modules SM User Manual Issue 3 Page 17 of 33 ADVANCED FEATURES These features may be utilized in the Canopy System but are not required for basic operation SECURITY DES ENCRYPTION Standard Canopy modules provide Data Encryption Standard DES encryption DES is a secret key encryption scheme using a 56 bit key The basics of DES are that it performs a series of bit permutations substitutions and recombination operations on blocks of data using a secret key On the Canopy system encryption of the over the air link
34. n that page To go back to the non Expanded Stats view just have the web browser refresh on the IP address of the module Clicking on the Expanded Stats link will display a number of pages of statistics that are maintained by the Canopy module Canopy Technical Support may ask the operator for specific information in this section when troubleshooting an issue There are 3 areas in the Expanded Stats that an operator can use for managing and troubleshooting a Canopy System Those 3 areas are e Link Test e Alignment e BER Display Link Test alex Ele ER yew Favertes Tools Heb pra DIS Ah aportes Jer DO R Agios fE rero 1192 93 18 42 o uris ye Ome CANOPY Link Capacity Test Duration 2 Seconds Start Test Current Result Status Stats for LUID 2 Test Duration 2 Downlink RATE 4921344 bps Uplink RATE 1184256 bps Downlink Efficiency 100 Percent Max Downlink Index 96 Actual Downlnk Index 96 Expected Frag Count 19224 Actual Frag Count 20017 Uplink Efficiency 100 Percent Expected Frag Count 4626 Actual Frag Count 4626 MD ronet Berar m S ED E cor tne Pave SSEBSMALODH mm The Link Test is a test for measuring the throughput and efficiency of the RF link between two Canopy modules To perform a link test enter a number into the field labeled Duration The duration is the number of seconds the RF link will be tested Start the link test by clicking the Start Test button The test
35. ncy The subscriber module does not have to be registered to an access point module for information on signal strength to be reported back This can simplify the aiming process for long links when the Canopy passive reflector 5 7GHz band only is being used To utilize RSSI only mode e Choose the frequency to monitor from the pick list this would be the same frequency that the access point module is transmitting on e Click the radio button to highlight Enable on RSSI Only mode e Click Enable Aiming Mode The module will now report back the level of RF energy present at that specific frequency To refresh the screen click the Enable Aiming Mode button as appropriate or configure the web page auto refresh option The normal operation of alignment mode will report information as it relates to the RSSI level Jitter value and number of users on the access point module To utilize normal alignment mode ensure that the Disabled radio button is checked and then click Enable Aiming Mode button As with the previous mode to refresh the mode either continue clicking the Enable Aiming Mode button or configure the auto refresh option Also during normal alignment mode the LEDs on the outside of the Canopy module will report back information on the performance of the link There are 6 LEDs and when in alignment mode the LEDs are turned into a 6 position bar graph The more LEDs that are lit the better the RSSI and Jitter values the module is
36. oftware If you are a Motorola licensed distributor when you are transferring the Software as permitted herein you agree to transfer the Software with a license agreement having terms and conditions no less restrictive than those contained herein You may transfer all other Software not otherwise having an agreed restriction on transfer to another party However all such transfers of Software are strictly subject to the conditions precedent that the other party agrees to accept the terms and conditions of this License and you destroy any copy of the Software you do not transfer to that party You may not sublicense or otherwise transfer rent or lease the Software without our written consent You may not transfer the Software in violation of any laws regulations export controls or economic sanctions imposed by the U S Government Right to Audit Motorola shall have the right to audit annually upon reasonable advance notice and during normal business hours your records and accounts to determine compliance with the terms of this Agreement Export Controls You specifically acknowledge that the software may be subject to United States and other country export control laws You shall comply strictly with all requirements of all applicable export control laws and regulations with respect to all such software and materials U S Government Users If you are a U S Government user then the Software is provided with RESTRICTED RIGHTS as set forth in s
37. omputer network that is connected to the module via the Ethernet cable If the address is designated a public address it will be accessible network wide The default for this feature is for the address to be local If the IP address is forgotten the operator will need physical access to the module and will need to create a Canopy default plug See steps at the end of this section for creation and use of a default plug LAN1 Subnet Mask enter in an appropriate subnet mask for the module to talk on the network The default value for this parameter is 255 255 255 0 Default Gateway enter in an appropriate gateway address for the module The default value for this parameter is 169 254 0 0 Color Code enter in a value 0 254 The color code on the subscriber module and the access point module must match in order for registration to occur Color code is not a security feature It is a means for the Canopy System operator to segregate an individual network or neighboring Canopy networks Also color code can be used to force a subscriber module to only register to a specific access point module even though the subscriber module may be able to see multiple access point modules The default value for this parameter is 0 on all Canopy modules Display Only Password enter the same password in both fields for verification The display only password when used will allow only view activities to the module When the display only password is se
38. our fold additional compliance margin is artificially introduced by doubling the distance to 20 cm In the case of the Canopy SM with reflector the gain is 26 dBi a factor of 400 so the peak power density equals the exposure limit at a distance of about 80 cm An almost four fold additional compliance margin is artificially introduced by defining the compliance distance of 1 5 m The compliance distance is greatly overestimated in this case because the far field equation neglects the physical dimension of the antenna which is modeled as a point source Software License Terms and Conditions ONLY OPEN THE PACKAGE OR USE THE SOFTWARE AND RELATED PRODUCT IF YOU ACCEPT THE TERMS OF THIS LICENSE BY BREAKING THE SEAL ON THIS DISK KIT CDROM OR IF YOU USE THE SOFTWARE OR RELATED PRODUCT YOU ACCEPT THE TERMS OF THIS LICENSE AGREEMENT IF YOU DO NOT AGREE TO THESE TERMS DO NOT USE THE SOFTWARE OR RELATED PRODUCT INSTEAD RETURN THE SOFTWARE TO PLACE OF PURCHASE FOR A FULL REFUND THE FOLLOWING AGREEMENT IS A LEGAL AGREEMENT BETWEEN YOU EITHER AN INDIVIDUAL OR ENTITY AND MOTOROLA INC FOR ITSELF AND ITS LICENSORS THE RIGHT TO USE THIS PRODUCT IS LICENSED ONLY ON THE CONDITION THAT YOU AGREE TO THE FOLLOWING TERMS Now therefore in consideration of the promises and mutual obligations contained herein and for other good and valuable consideration the receipt and sufficiency of which are hereby mutually acknowledged you and Motorola agree as fol
39. r module contains a series of web pages that are used to interface to the unit The following is a quick reference to interface screens Mote These screens are subject to change by subsequent software versions To access the web based interface you first must be on a computer that is in some way connected to the subscriber module This can be done either directly or through a network Enter the IP address of the subscriber module default is 169 254 1 1 into the address bar of your browser and hit enter on your keyboard The following web based interface pages are accessible Status Configuration Event Log AP Eval Data Ethernet Stats Expanded Stats The default page when accessing the IP address of the Canopy unit is the Status page STATUS PAGE E Canopy neme noge re aleiz Hid gt OD A Quero apote Ger e Se IOR ee ho C AN 9 P Y Dence type 5 2GHz Mulnpows Subsenber Modem Da 00 3e 00 02 2f 3 1 5 Sep 06 2002 1331 09 SM ull Duplex Subscriber Modem Stats Sesnon Status REGISTERED RSSI 1664 Jates Ax Delay 5 approximately 0 05 males 245 feet Rado Slicing Valse 564 decimal Radio Transmit Gain Setting 24 decimal Site Information See Name No See Name Site Contact No Ste Contact O time el Mstort MEAR Eta home Page Mer LIL BDBALODB m The Status page contains information on the operation of the product It is the default webpage The following parameters are displayed
40. red access point module At close range 0 200 feet the distance will not report accurately Radio Slicing Value displays information to be used by Canopy technical support Radio Transmit Gain Setting displays information to be used by Canopy technical support Site Name displays information relating to the name of the physical module This parameter can be set by the operator on the Configuration web page This information is set into the sysName SNMP MIB II object and can be polled via a SNMP management server Site Contact displays contact information for the physical module This parameter can be set by the operator on the Configuration web page This information is set into the sysContact SNMP MIB Il object and can be polled via a SNMP management server CONFIGURATION lala Ele EGR yew Favores Tools Heb puke DS Qe Capote Gor th Sf OR Address E rarp 11192 93 18 42 Ooo us mm on Status Parameter Value Configuration 5 2GHz Mulnpomt Subscriber Modem 0a 00 3e 00 02 2 F 10 Base T Half Duplex Event Log s S F 10 Base T Full Duplex TAP Eval Data Link Negotiation Speeds 5 100 Base T Half Duplex Ethernet State F 100 Base T Ful Duplex Custom RF Frequency Scan IM 5275 M 280 M 5285 M 5290 M 5295 M 5300 Selection SM List I 5310 M 315 M 5320 5325 F None Lal P fis Network Accessibility C Local Pubie Leal Subnet Mask Default Gateway 192 9318254 Color Code 0 m D Only Access Password No Passwor
41. scriber module for the Canopy network Install the module Align the module UNPACK THE CANOPY PRODUCTS Upon receipt carefully inspect all shipping boxes for signs of damage If there is damage immediately notify the transportation company Unpack equipment making sure that all ordered components have arrived It is recommended that you save all the packaging materials They can be used for transportation of the equipment to and from installation sites CONFIGURING THE SUBSCRIBER MODULE A In all cases when a configuration parameter is modified the change must be saved and the module must be rebooted The subscriber module from the factory is configured to scan all available frequencies in its specific frequency band An operator will need to verify the following information The operator may program a unique IP address into the subscriber module or can leave it at its defaults The subscriber module is programmed to utilize the local IP address of 169 254 1 1 When configured in this manner the IP address is not accessible from the far side of a RF link to the module If the operator requires that the LAN IP of the subscriber module be accessible from across the RF link then the public IP address feature is recommended This feature will require that a routable IP address and appropriate subnet mask and gateway be utilized The operator must configure the appropriate color code on the subscriber module so that it can register with
42. ss Points and Cluster Management Modules The environment these modules operate in often has significant or unknown or varying RF energy and experience has been that the additional cost of shielded cabling is more than compensated by predictable operation and reduced debugging and support costs The following information describes the wiring standards for installing a Canopy system All diagrams use the EIA TIA 568B color standard Currently shipping modules auto sense the Ethernet cable type either RJ 45 straight thru cable or RJ 45 crossover cable can be used to connect a network interface card NIC hub router or switch to a module The following table shows MAC Addresses of Auto sensing modules MAC Address ESN Non auto sensing Auto sensing 5 2 Modules lt 0a003e0021c8 gt 0a003e0021c9 5 7 Modules lt 0a003ef00f79 gt 0a003ef00f7a Earlier modules did not auto sense In cases where older modules are used e When connecting a Canopy device directly to a network interface card NIC use a RJ 45 straight thru cable e When connecting a Canopy device directly to a hub switch or router use a RJ 45 crossover cable When using the Canopy AC wall adapter the V is 11 5VDC to 30VDC with a nominal value of 24 VDC and the maximum Ethernet cable run with the AC wall adapter is 328 feet 100 meters RJ 45 Straight Thru Pin RJ 45 Straight Thru Pin pini gt white orange
43. subscriber module Utilize stainless steel hose clamps to secure the module to the arm The module is now properly aligned within the reflector TE HN Stainless steel hose clamps Reflector dish arm INSTALLATION OF THE SUBSCRIBER MODULE When power is applied to a Canopy module or the unit reset via the web based interface the module will take approximately 25 seconds to boot up During this boot up time power on self tests and other diagnostics are being performed The following steps must be performed for successful installation Select a mounting location that is free from objects such as buildings large trees etc that will interfere with the line of sight to the Access Point cluster location Be mindful of the Fresnel Zone e The Canopy module should be mounted vertically as shown in FIGURE 3 All Canopy modules antennas are vertically polarized in this direction e Mount the Canopy subscriber module to a secured location on the side roof of the building The mount must be rigid and the subscriber module must not sway from outside forces e Illustrated in FIGURE 3 is an example of mounting the unit to an antenna mast Stainless steel hose clamps or any suitable outdoor equivalent may be used to secure the unit to the mast SM User Manual Issue 3 Page 12 of 33 Stainles lt Steel Host Clamps ol any Suitabl a 7 Equivalen Typical Antenna Mast FIGURE 3 e Leave the unit moun
44. t and not the full access password the display only password will be tied to telnet and FTP sessions to the module If the full access password is also set then it has precedence on the telnet and FTP sessions If the password is forgotten the operator will need physical access to the module and will need to create a Canopy default plug to override the unit See steps at end of section for use and creation of a default plug Full Access Password enter the same password in both fields for verification The full access password when used will allow view and change activities to the module When the full access password is set the password will also be tied to telnet and FTP sessions to the module When prompted for the password via the web based interface there is no username required however when prompted for the password via a telnet or FTP session the user that MUST be used is root If the password is forgotten the operator will need physical access to the module and will need to create a Canopy default plug to override the unit See steps at end of this section for use of a default plug Webpage Auto Update enter time period in seconds desired to have the web browser refresh the web based interface The default setting is 0 which will cause the web based interface to never refresh SM Power Up Mode with No 802 3 Link choose which mode the module will default to when there is no Ethernet connection sensed by the module
45. t be configured in the same fashion The field Measured Bit Error Rate will display a value that corresponds to the BER at the moment of web browser refresh An acceptable link will have a BER that is less than 10 If the BER is greater than 10 then the operator needs to evaluate the subscriber and or access point module installation for potential issues To refresh the screen click the Refresh Display button as appropriate or configure the web page auto refresh option ACCESSORIES The following accessories are available for use with the Canopy System To purchase accessories please contact an authorized Canopy dealer unless otherwise noted e Universal mounting bracket part number SMMB 1 e Passive reflector dishes for use with 5 7 GHz subscriber modules part number 27RD e 102 132 V AC power supply with North American plug part number ACPS110 e 100 240 V AC power supply with North American UK and Euro plugs part number ACPSSW 02 e Cable assemblies for the Canopy System can be ordered from Best Tronics Manufacturing Inc by going to their website at http www best tronics com motorola Due to the RF environment Canopy Backhauls Access Points and Cluster Management Modules often operate in it is strongly recommended to use shielded cable for infrastructure cabling connecting these modules APPENDIX There are two basic concepts that are needed for a basic understanding of networking IP addresses and subnet masks IP a
46. ting means loose enough to allow for movement when performing the alignment procedure They must be tightened after the alignment procedure is completed As with any such installed devices the Canopy subscriber module and the Ethernet cable must be grounded in accordance with the latest revision of the National Electrical Code NEC and or all country and local electrical codes to provide some protection against damage caused by near miss lightning strikes and other electrical discharges The Canopy Ethernet surge suppressor is such a device for this situation e Connect one end of an Ethernet cable to the Canopy subscriber module RJ 45 connector e Connect other end of the Ethernet cable to the RJ 45 connector in the Canopy surge suppressor Refer to the Surge Suppressor User Manual for specifications e Connect one end of another Ethernet cable to the other RJ 45 connector in the Canopy Surge Suppressor e Connect the other end of the Ethernet cable to the AC adapter The unused pins of the Ethernet cable 4 5 7 and 8 transmit power to the Canopy subscriber module DO NOT place other networking equipment on the Ethernet cable between the AC adapter and the subscriber module The module can be up to 328 feet 100 meters from the power supply e Plug the AC Adapter into an AC outlet e Plug the other side of the AC adapter s Ethernet pig tail into the computer or network computer s Ethernet port DO NOT plug the Ethernet pig
47. tion This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with these instructions may cause harmful interference to radio communications If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment on and off the user is encouraged to correct the interference by one or more of the following measures Increase the separation between the affected equipment and the unit s Connect the affected equipment to a power outlet on a different circuit from that which the receiver is connected to Consult the dealer and or experienced radio TV technician for help FCC IDs and Industry Canada Certification Numbers are listed in the following table Module Operating Frequency Maximum Reflector FCC ID Industry Canada Types Range Transmitter Cert Number Power SM AP BH U NII 5250 5350 MHz 200mW Not Allowed ABZ89FC3789 109W 5200 SM AP BH U NII 5725 5825 MHz 200mW Allowed on SM and ABZ89FC4816 109W 5700 BH SM AP BH ISM 5725 5850 MHz 200mW Allowed on SM and ABZ89FC5804 109W 5700 BH The term IC before the radio certification number only signifies that Industry Canada technical specifications were met European Community Notification Notification of Intended Purpose of Product Uses This product is a two way radio transceiver suitable for use in Broadband RLAN systems It uses oper
48. to a higher layer protocol innucastpkts count displays the total number of non unicast i e subnetwork broadcast or subnetwork multicast packets delivered to a higher layer protocol indiscards count displays the total number of inbound packets which were chosen to be discarded even though no errors had been detected to prevent their be deliverable to higher layer protocol One possible reason to discard could be to free up buffer space inerrors count displays the total number of inbound packets that contained errors preventing them from being delivered to a higher layer protocol inunknownprotos count displays the total number of packets received via the interface which were discards because of an unknown or unsupported protocol outoctets count displays the total number of octets transmitted out of the interface including framing characters outucastpkts count displays the total number of packets that higher level protocols requested be transmitted to a subnetwork unicast address including those that were discarded or not sent outnucastpkts count displays the total number of packets that higher level protocols requested be transmitted to a non unicast i e subnetwork broadcast or subnetwork multicast address including those that were discarded or not sent outdiscards count displays the total number of outbound packets which were chosen to be discarded even though no errors had been detected to prevent their being transmitt
49. ubparagraphs c 1 and 2 of the Commercial Computer Software Restricted Rights clause at FAR 52 227 19 or subparagraph c 1 i1 of the Rights in Technical Data and Computer Software clause at DFARS 252 227 7013 as applicable Disputes You and Motorola hereby agree that any dispute controversy or claim except for any dispute controversy or claim involving intellectual property prior to initiation of any formal legal process will be submitted for non binding mediation prior to initiation of any formal legal process Cost of mediation will be shared equally Nothing in this Section will prevent either party from resorting to judicial proceedings if i good faith efforts to resolve the dispute under these procedures have been unsuccessful ii the dispute claim or controversy involves intellectual property or iii interim relief from a court is necessary to prevent serious and irreparable injury to that party or to others General Illinois law governs this license The terms of this license are supplemental to any written agreement executed by both parties regarding this subject and the Software Motorola is to license you under it and supersedes all previous oral or written communications between us regarding the subject except for such executed agreement It may not be modified or waived except in writing and signed by an officer or other authorized representative of each party If any provision is held invalid all other provisions shall rema
50. urther information e Go to Alignment web page Ensure that RSSI Only Mode is disabled e Click Enable Aiming Mode button e The module has a series of states that it will go through to register to an access point Those states are scanning syncing registering and registered RSSI and Jitter will not report on the web page till the unit is registered If the module will not register ensure that there is line of sight the access point module is transmitting the color codes match and that the subscriber is within the appropriate distance to the access point as specified by Canopy e Slowly adjust the positioning of the subscriber module and monitor the Alignment web page for a reading of the RSSI and Jitter Lock down the module when appropriate e Click Disable Aiming Mode button e Perform a link test to check the efficiency of the link See Link Test section for further information The efficiencies must be above 90 in both the up and down link for major packet loss to not occur SM User Manual Issue 3 Page 15 of 33 CABLING The RF environment the Subscriber Module operates in often will permit use of unshielded cable However in cases where cable interference issues are suspected or as part of A B comparisons to debug field problems use of shielded cable with Subscriber Modules may be warranted It is strongly recommended to use shielded cable for all Canopy infrastructure cabling associated with Backhauls Acce
51. y and will take effect after the next module reboot Undo Save Changes by clicking on this button any changes that have been made and not committed through a reboot of the module will be undone Set to Factory Defaults depressing this button will change all of the configurable parameters all of which are contained on the Configuration page back to their factory settings Reboot depressing this button will reboot the module Canopy Default Plug When inserted the default plug brings the module up with a default configuration This allows the operator to regain control of a module which may be using an IP address and or password that has been forgotten The default plug will also override the passwords for access and change control and set the LAN1 IP address back to 169 254 1 1 This does not by itself change any configuration rather it allows the operator to attach to the module using the default configuration so that they can read the actual non default values and set them accordingly The following steps outline the creation of a default plug this plug can also be purchase for a nominal fee at http www best tronics com motorola e Obtain a RJ 11 6 pin connector and a small length of CAT 5 cable e Pin out all 6 pins according the following diagram and then short i e solder together pins 4 and 6 on the other end Remaining wires should not be connected to anything The following diagram shows the wiring of a default plug
Download Pdf Manuals