Home
3. Vario-Sense® CO-Busmeßkopf 2
Contents
1. The logger connection is on contact 1 signal and contact 2 signal If your transmitter assignments for the signal and signal are different please do not forget to adjust male contacts of your angle type plug accordingly To do so open the angle type plug and remove the red and the blue wires entering the housing from the coupling of the angle type plug Connect wires with the respective contacts representing signal blue wire and signal red wire at your transmitter Input Signal 0 20 mA In the angle type plug the male contacts 1 2 and 4 are directly connected 1 1 with the socket The T Logg Rs 70 Ohm is located between the male contact 3 and the jack 3 pin contact jack If the signal line in your transmitter is not assigned to contact 3 please do not forget to adjust the logger angle type plug and the external angle type plug accordingly To do so open the logger angle type plug and exchange the black wire of contact 3 against the wire of the contact representing the signal in your transmitter Then exchange and or rewire the two contacts in the angle type plug of your connecting cable How to change the assignment of the angle type plug e Dismantle the plug by pulling the adapter inset out of the case using a screw driver at the lateral groove Input Signal 4 20 mA In the angle type plug the male contacts 1 3 and 4 are direct
2. Analog Digital Datalogger T Logg 120 Data Logger for Standard Signals T Logg 120 K and T Logg 120 W As of version 1 0 User Manual December 2010 PolyGard is a registered trademark of MSR Phone 0049 0 8531 9004 0 Fax 0049 0 853 1 9004 54 MSR Electronic GmbH Wiirdinger Str 27 D 94060 Pocking www msr electronic de GAT Logg120_E_1210 Specification subject to change without notice Printed in Germany User Manual T Logg 120 ZN JMSR Page 2 C Fj E E a AN E E E E E EE E E E 3 2 RegUNeU ACCESSORY ccin a a e aa 3 DSTO UY INSTOU CIONS aaa E EA EAE R ERE 3 A CONNECCION eina A E EO E E EEE 3 A Eae COE I a a oss arcatewe naa neeteaasearenneunaraaen senate 3 4 2 T Logg 120 W Assignment of the Angle type PIUQ cccccccecssseeeeeeeeeeesseeseesseeeeesneeeeeens 4 4 3 T Logg 120 K Assignment of the Connection Cable cccccccccccccssssseeeeeeeeessseeseeeeeeeeeseaas 5 5 Advice Regarding State of Logger upon Delivery cccsesseeceeeseeeeeenseeseenseeeceaneeesoenseeseonees 5 6 Configuration of the Display Range ccccsscssecessesssseeeeeenseeeeeeeesseeeseoesseeeeeoensseeseooenseeseoeeaseesnens 5 Operating Mode DIS DAY sssusa aa a Ea a ia a i aa Eae E 5 8 Battery service life and recording t Me sssssnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn nnmnnn mnnn 6 9 Bater epa CS IN ce E e 7 MO SS CUI A ONS ete secs se ise deste tec a A E E 8 11 ESOS hh INS CEN U
3. S cates ce eee cee cc ee ice cme eee ee cemeeeemeneeeen 8 12 NOTES and Genel al INTORMN AU OM siswsdscsisashinnesisaessdaded culodetessdines aaa 9 12 1 Intended Product AppliCation ccccccssssccceccesseceecceesseceeeceeusececeeseuecessesaeeeeessaaseeesssageeeessaas 9 12 2 Installers Responsibilities 2 0 ce eeccccsesceecaeeeeeeneeeeeeeeeeesaeeeeeeeeeseeeeeaseeeesaeeessageeeesseeeeesneeeeeeas 9 12 3 EAEE E E E E E E A A A A E E A N AT 9 12 4 Limited Wa rrranty cecccccccsssseccccceeseeeeeceeeeseeeeceeasceeecsuasseeeesesauseeeessaseceeessauesessssaasecessssagseeess 9 PolyGard is a registered trademark of MSR GAT Logg120_E_1210 Phone 0049 0 8531 9004 0 Fax 0049 0 8531 9004 54 Specification subject to change without notice MSR Electronic GmbH W rdinger Str 27 D 94060 Pocking www msr electronic de Printed in Germany User Manual T Logg 120 a Page 3 C J T 1 General The logger T Logg 120 is designed as a cost efficient solution for monitoring standard signals It enables an individual programming of the recording time The last 16 000 measuring values can be stored in the memory In addition the LCD display indicates both the temperature measured at the moment and the operating status of the logger 2 Required Accessory The USB interface of your PC is used to program start and read out the T Logg For this following accessory is required e Interface converter USB 100 or USB 100 SL for direct connection to th
4. SR Electronic GmbH Wiirdinger Str 27 D 94060 Pocking GAT Logg120 E 1210 Specification subject to change without notice www msr electronic de Printed in Germany User Manual T Logg 120 yo 12 Notes and General Information lt is important to read this user manual thoroughly and clearly in order to understand the information and instructions The MSR Electronic devices must be used within product specification capabilities The appropriate operating and maintenance instructions and recommendations must be followed Due to on going product development MSR reserves the right to change specifications without notice The information contained herein is based upon data considered to be accurate However no guarantee is expressed or implied regarding the accuracy of this data 12 1 Intended Product Application The MSR Electronic devices are designed and manufactured for control applications and air quality compliance in commercial buildings and manufacturing plants i e detection and automatic exhaust fan control for automotive maintenance facilities enclosed parking garages engine repair shops warehouses with forklifts fire stations tunnels etc 12 2 Installers Responsibilities It is the installers responsibility to ensure that all MSR Electronic devices are installed in compliance with all national and local codes and OSHA requirements Installation should be implemented only by technicians familiar with proper installation
5. e USB port of the PC cable length approx 1m e MINISOFT software version 7 18 or later free of charge to start the logger and read out the logger data Notice _ It s also possible to use the T Logg with the comprehensive software GSOFT 40K version 7 18 or later 3 Safety Instructions This device has been designed and tested in accordance with the safety regulations for electronic devices However its trouble free operation and reliability cannot be guaranteed unless the standard safety measures and special safety advises given in this manual will be adhered to when using the device 1 Trouble free operation and reliability of the device can only be guaranteed if the device is not subjected to any other climatic conditions than those stated under Specification To protect the battery the max permissible storage and transport temperature of the device is 85 C 2 General instructions and safety regulations for electric light and heavy current plants including domestic safety regulations e g VDE have to be observed 3 If device is to be connected to other devices e g via PC the circuitry has to be designed most carefully Internal connection in third party devices e g connection GND and earth may result in not permissible voltages impairing or destroying the device or another device connected 4 f there is a risk whatsoever involved in running it the device has to be switched off immediately and to be marked accordi
6. ired the logger will start recording in accordance with the starting conditions programmed before START ALARM The logger is active but no data are recorded Recording will start as soon as the measured value is within the min and max alarm limits BATTERY e Changing display BAT Value The battery of the T Logg is getting discharged soon Replace the battery briefly Even so data logging is still active e Constant display BAT The Logger battery is empty now and data logging has been stopped Replace the battery immediately PolyGard is a registered trademark of MSR GAT Logg120 E 1210 Phone 0049 0 8531 9004 0 Fax 0049 0 853 1 9004 54 Specification subject to change without notice MSR Electronic GmbH Wiirdinger Str 27 D 94060 Pocking www msr electronic de Printed in Germany User Manual T Logg 120 a R ALARM LOW ip poo The measured value is below the min alarm limit IIL LLI ALARM HIGH pl Hy The measured value has exceeded the max alarm limit ERROR 1 The input signal has exceeded the measuring range of the logger ERROR 2 The input signal has been fallen below the measuring range of the logger ERROR 3 J The max display range 9999 of the logger is exceeded CrP ERROR 4 The min display range 1999 of the logger is under run ERROR 7 The T Logg has detected a system fault e Remedy Remove battery and wait about 30 minutes Then insert the battery again e If the error message d
7. isplayed furthermore please send the logger to the manufacturer to repair 8 Battery service life and recording time Measuring cycle 2 Sec 10 sec 15 min 5 hours Recording time 8 9 hours 44 hours 166 days Approx 9 years Battery service life Approx 1 year Approx 3 years Please note Short measuring cycles as well as frequently measuring data transfer result in a reduction of the battery service life Even if the T Logg is connected power consumption is increased So it s important to connect the logger with the USB interface of the PC only as long as necessary PolyGard is a registered trademark of MSR GAT Logg120 E 1210 Phone 0049 0 8531 9004 0 Fax 0049 0 853 1 9004 54 Specification subject to change without notice MSR Electronic GmbH Wiirdinger Str 27 D 94060 Pocking www msr electronic de Printed in Germany User Manual T Logg 120 aa MSR Page 7 aI z 9 Battery replacement Notice As soon as BAT appears at display the battery needs to be replaced If battery voltage power decreases continuously data logging will be stopped compare with operating status HALT Available stored data remains in the memory and do not get lost It s possible to read the measuring data after replacement of the battery Replacement 1 Remove the 4 screws at the front of the logger with a small screwdriver and remove the cover from housing 2 Take out the PCB and deposit it carefully beside the housing
8. ly connected 1 1 with the socket The T Logg Rs 70 Ohm is located between the male contact 2 and the jack 2 pin contact jack If the signal GND line in your transmitter is not assigned to contact 2 please do not forget to adjust the logger angle type plug and the external angle type plug accordingly To do so open the logger angle type plug and exchange the red wire of contact 2 against the wire of the contact representing the signal GND in your transmitter Then exchange and or rewire the two contacts in the angle type plug of your connecting cable e Change the assignment according to the notes at the respective input signal e Latch coupling insert in cover You have a choice between 4 different orientations each of them Spaced 90 e Please make sure to adjust the connecting cable if the assignment of the angle type plug has been changed for the types 4 20mA and 0 20mA e Put on angle type plug and connect plugs using the long screw delivered Do not forget seals PolyGard is a registered trademark of MSR Phone 0049 0 8531 9004 0 Fax 0049 0 853 1 9004 54 MSR Electronic GmbH Wiirdinger Str 27 D 94060 Pocking www msr electronic de GAT Logg120 E 1210 Specification subject to change without notice Printed in Germany User Manual T Logg 120 a 4 3 T Logg 120 K Assignment of the Connection Cable The connection cable has following assignment Wire colou
9. ngly to avoid re starting Operator safety may be a risk if there is visible damage to the device the device is not working as specified the device has been stored under unsuitable conditions for a longer time In case of doubt please return device to manufacturer for repair or maintenance 5 Warning Do not use this product as safety or emergency stop devices or in any other application where failure of the product could result in personal injury or material damage Failure to comply with these instructions could result in death or serious injury and material damage 4 Connection 4 1 Interface Connection Assignment of the input jack front view to the pins interface not connected interface PolyGard is a registered trademark of MSR GAT Logg120 E 1210 Phone 0049 0 8531 9004 0 Fax 0049 0 853 1 9004 54 Specification subject to change without notice MSR Electronic GmbH Wiirdinger Str 27 D 94060 Pocking www msr electronic de Printed in Germany User Manual T Logg 120 E 4 2 T Logg 120 W Assignment of the Angle type Plug Table of connections angle type socket and jack 0 X Volt feeded through signal feeded through feeded through feeded through signal feeded through T Logg feeded through T Logg feeded through feeded through feeded through feeded through Input Signal 0 X Volt In the angle type plug the 4 male contacts are directly connected 1 1 with the socket
10. or related to the use of the MSR Electronic transmitters PolyGard is a registered trademark of MSR GAT Logg120 E 1210 Phone 0049 0 8531 9004 0 Fax 0049 0 853 1 9004 54 Specification subject to change without notice MSR Electronic GmbH Wiirdinger Str 27 D 94060 Pocking www msr electronic de Printed in Germany
11. r Meaning red 5 Advice Regarding State of Logger upon Delivery Upon its delivery the logger is in a kind of sleeping state The display does not show anything the power consumption is at its minimum The T Logg wakes up as soon as a communication link with a software has been established After that the message Stop appears at display The logger is ready for operation now 6 Configuration of the Display Range The display range position of decimal point and the display unit can be set by the software MINISOFT or GSOFT 40k in the register Settings Furthermore it can be used to read out sensor information and to program the alarm points of the logger 7 Operating Mode Display The T Logg is equipped with a 10 mm LCD display The main purpose of the LCD display is to indicate the measured value Depending on the operating mode of the logger other messages will be displayed as well STOP Cc L m The T Logg is stopped No data are recorded The logger memory is empty JL Ll The logger is reset and can be restarted HALT The T Logg has been halted The stored data can be read The logger memory is not empty DISPLAY OF MEASURED VALUE The small arrow is flashing The logger is active Measurements are carried out at certain intervals The measured value will be stored START DELAY LL IL The logger is active but no data are recorded JO OC As soon as the start delay time has exp
12. tance 100 kOhm T Logg 120 002 0 2 Volt input resistance 200 kOhm T Logg 120 010 0 10 Volt input resistance 500 kOhm T Logg 120 020 0 20 mA shunt resistance 70 Ohm T Logg 120 420 4 20 mA shunt resistance 70 Ohm FILLING MEMORY gt gt Once the memory is filled with data the recording will automatically be halted RING MEMORY gt gt The old data will be overwritten in case of memory overflow the measured values are monitored at alarm limits Alarm limit and alarm delay 0 500 min adjustable via interface approx 3 years if interval is 15 min depending on measuring cycle and operating temperature serial interface 3 pin miniature plug Please note the input is not isolated from the interface T SS eee 48 5 x 48 5 x 35 5 mm H x W x D plug an fixation flap not included Housing made of shock resistant plastic transparent front made of polycarbonate splash water proof IP65 The T Logg 120 have been manufactured in accordance with the regulations concerning EMC 2004 108 EG The device meets EN 61326 1 2008 Additional error lt 1 11 Disposal instructions The device must not be disposed in the regular domestic waste Send the device directly to us sufficiently stamped if it should be disposed We will dispose the device appropriate and environmentally sound PolyGard is a registered trademark of MSR Phone 0049 0 8531 9004 0 Fax 0049 0 853 1 9004 54 M
13. techniques and with codes standards and proper safety procedures for control installations and the latest edition of the National Electrical Code ANSI NFPA70 It is also essential to follow Strictly all instructions as provided in the user manual 12 3 Maintenance It is recommended to check the MSR Electronic device regularly Due to regular maintenance any performance deviations may easily be corrected Re calibration and part replacement in the field may be implemented by a qualified technician and with the appropriate tools Alternatively the device may be returned for service to MSR Electronic GmbH 12 4 Limited Warranty MSR Electronic GmbH warrants the MSR Electronic devices for a period of one 1 year from the date of shipment against defects in material or workmanship Should any evidence of defects in material or workmanship occur during the warranty period MSR Electronic GmbH will repair or replace the product at their own discretion without charge This warranty does not apply to units that have been altered had attempted repair or been subject to abuse accidental or otherwise The warranty also does not apply to units in which the sensor element has been overexposed or gas poisoned The above warranty is in lieu of all other express warranties obligations or liabilities This warranty applies only to the MSR Electronic devices MSR Electronic GmbH shall not be liable for any incidental or consequential damages arising out of
14. with the LCD display face down Take care not to damage the gasket 3 Push out the button cell carefully from socket see picture at the top on the right 4 Insert the new button cell type CR 2032 with correct polarity in the socket the positive pole is on the retaining bracket see picture at the bottom on the right 5 Reinsert the PCB correctly LCD face up into the housing see picture in the middle on the right 6 Reassemble the housing Use the 4 screws to fix the cover again Environmental Reference Empty and defective batteries must not be disposed in the regular domestic waste Return the used batteries to an authorised battery collecting point or send the batteries directly to us sufficiently stamped PolyGard is a registered trademark of MSR GAT Logg120 E 1210 Phone 0049 0 8531 9004 0 Fax 0049 0 853 1 9004 54 Specification subject to change without notice MSR Electronic GmbH Wiirdinger Str 27 D 94060 Pocking www msr electronic de Printed in Germany User Manual T Logg 120 am 10 Specifications Display range scaling Decimal point Accuracy Display Recording Interval Measuring value memory Memory type Recording time Alarm function Nominal temperature Working temperature Storage temperature Battery Battery service life Data communication Electric connection T Logg 120 K T Logg 120 W Dimensions housing EMC T Logg 120 001 0 1 Volt input resis