USER MANUAL KOMINEK LUX (RT-08P)

image

Contents

1. and electric devices must be transfered to Ph 071 794 43 01 Dz a Y Q IEVAS a Zaktad elektroniczny TATAREK Jerzy Tatarek 50 559 Wroclaw 75 Swieradowska st ph 071 367 21 67 373 14 88 fax 373 14 58 tax index number 899 020 21 48 Bank account BZ WBK S A O WROCLAW 6910901522 0000 0000 5201 9335 www tatarek com pl E mail tatarek tatarek com pl PP O O Air Throttle S e O 8 i Temperature _ T2 sensors T a l gt T3 Ta A 9 0 N NININ WS 3 2 CONTROL Pump P1 N MAINS 230V 50Hz E TF 230V 50Hz Pump P2 230V 50Hz Pump P3 230V 50Hz Fig 3 Electrical scheme PP Air throttle Tl Upper temperature sensor of WAW accumulator option T2 Lower temperature sensor of WAW accumulator T3 Temperature sensor of fireplace water jacket P1 Pump supplying WAW accumulator from a fireplace P2 Pump of the primary side of heat exchanger it operates if P1 or P2 is activated P3 Circulating pump CH e Keeping the accumulator WAW at maximal readiness Parameter CtrIWAW 1 The supply starts if the lower temperature sensor of WAW T2 shows temperature below 65 C l maxWAW parameter e Optimal supply Parameter Ctr WAW 2 from partial discharge to max supply The supply turns on if the upper temperature sensor of WAW T1 shows temperature lower than 50 C T minWAW parameter and turns off if the lower temperatu
2. parameter If WAW temperature exceeds 65 C max WAW parameter the pump WAW turns off There are 2 ways of supplying the accumulator WAW 4 WARRANTY 1 Warranty is valid 24 months from the date of sale 2 Producer does not take responsibility for any mechanical damages made by user 3 MAKING REPAIRS OR MODYFYING THE DEVICE BY USER IS FORBIDDEN AND CAUSES WARRANTY CANCELATION 4 Warranty card is valid only with date of sale seller s signature and stamp 5 Warranty and after warranty repairs should be done only by producer damaged regulators should be sent to producer in order to make all repairs needed 6 Warranty protection involves the EU 7 Warranty does not exclude not restrict and not suspend buyer s rights coming from the incompatibility of the article with the agreement Laws Journal No 141 Pos 1176 WARNING ANY MODIFICATION OF THE REGULATOR MADE BY USER CAN BE THE CAUSE OF SAFETY CONDITIONS DETERIORATION AND CAN EXPOSE THE USER TO ELECTRIC SHOCK OR DAMAGE DEVICES SUPPLIED WARNING 1 Producer does not take the responsibility for damage caused by atmospheric discharge 2 and overvoltage in the mains 3 Burnt fuses are not subject to warranty replacement Date of sale Seller s signature and stamp ARGO FILM Recycling Plant No 6 180 Krakowska st 52 015 Wroclaw Register No GIOS E 0002240WZ Worn out electronic the utilization collection place where will 0 515 122 142 be accepted for free
3. 20 secs i Pause parameter During the movement the control lamp 9 is lit The blinking means the drive overload because of met resistances The shutdown of the regulator automatically causes the throttle to be set at rest position defined by ModeOFF parameter Factory setting is 0 full shut off 2 2 Pump CH operation If fireplace temperature exceeds a set value of 45 C CH ON parameter the pump CH turns on The switch off of the pump below the value causes a faster heating of the water jacket above the dew point and by that a longer life time of the fireplace During supplying the warm applicable water accumulator WAW the pump can operate cyclically if the WAW priority is set Limitation of the heat amount flowing into the system CH The cyclical operation is based on turning on the pump for 45 secs and then turning off for 4min Ti EndCH parameter The regulator protects the system from freezing automatically turning on the circulating pump if the measured temperature is below 4 C The regulator realizes the after season rundown of the pump by switching it on for 1 min if it doesn t operate for a week 2 3 Pump WAW operation The regulator controls as well the pump supplying the warm applicable water accumulator WAW The pump WAW is to turn on if water temperature in fireplace is higher than the threshold of 45 C CT WAW ON parameter and higher than in the accumulator WAW by 5 C DeltaWAW
4. GULATOR SHOULD NOT BE EXPOSED TO WATER AFFECTING ITS ENVIRONS OUGHT TO BE CLEAN THE PRODUCER DOESN T TAKE ANY RESPONSIBILITY FOR DAMAGES CAUSED BY WRONG USAGE OF THE REGULATOR Connection diagram of the elements of the regulator is presented on fig 3 aJi PARAMETERS OF LEVEL 1 NAME RANGE FACTORY FUNCTION SETTING T Firep 45 85 C 70 C Set temperature of fireplace kept by the regulator T CH ON 30 60 C 50 C Minimal temperature of fireplace at which the pump P3 CH is activated T WAW ON 20 85 C 50 C Minimal temperature of fireplace at which the pump P1 WAW turns on T maxWAW 30 100 65 C Maximal temperature of WAW accumulator The exceeding C turns off the supply pump T min WAW 30 100 50 C Minimal temperature of WAW accumulator The exceeding C turns on the supply pump DeltaWAW 1 10 C 2 C Minimal difference between fireplace and WAW accumulator temperature needed for the pump operation P1 WAW PARAMETERS OF LEVEL 2 FACTORY NAME RANGE SETTING FUNCTION Zonel fr 0 00 23 45 6 00 Start of lst time zone Zonel to 0 00 23 45 8 00 End of Ist time zone Zone2 fr 0 00 23 45 14 00 Start of 2nd time zone Zone2 to 0 00 23 45 17 30 End of 2nd time zone Zone3 fr 0 00 23 45 20 00 Start of 3r
5. WNAS Zak ad elektroniczny TATAREK Jerzy Tatarek 50 559 Wroclaw 75 Swieradowska st ph 071 367 21 67 373 14 88 fax 373 14 58 Tax index number 899 020 21 48 Bank account BZ WBK S A WROCLAW 6910901522 0000 0000 5201 9335 www tatarek com pl E mail tatarek tatarek com pl 6 NAS Zak ad elektroniczny TATAREK Jerzy Tatarek RT08P 2008 v 1 8 ANG USER MANUAL KOMINEK LUX RT 08P REGULATOR OF HEATING SYSTEM WITH A FIREPLACE CONTROLLED BY AIR THROTTLE WN eo Kominek wt o The regulator controls heating system based on a water jacket fireplace that is a heat source in which combustion process is controlled by air throttle The heat receivers are Warm Applicable Water accumulator WAW and Central Heating system CH 1 Basic technical parameters Power Power consumption without load Max connection power Operation conditions Housing protection class Fuse Number of outputs to control pumps Number of nonvoltage outputs Number of outputs to control a throttle drive Number of water temperature sensors Temp measurement precision Temp measurement resolution Number of time zones 230V 50Hz 5W 750W 0 50 C humidity 10 90 No condensation IP41 6 3A 250V 3 250W 230V 50Hz 1 1 5V 500mA DC 3 KTY81 0 100 C 2 C 0 5 C 4 2 Principle of operation The first function of the regulator is to keep temperature in the water jacke
6. all parameters to their factory pre sets and restart the regulator 10 3 2 Screens Alarm screens is not seen till the following emergency situation takes place 1 Damage of sensor T1 upper one of WAW T1 shows up The alarm doesn t work if the sensor is not installed 2 Damage of sensor T2 lower one of WAW T2 shows up 3 Damage of sensor T3 of fireplace T3 shows up 4 The exceeding of the acceptable temperature of fireplace 7 Firep defined by the 7 Alarm parameter Emergency situation is accompanied by a broken sound alarm that can be turned off by pressing the CONFIRM button In emergency of temperature exceeding the pump CH turns on to cool off fireplace Screen of fireplace water jacket temperature measurement shows the actual temperature of fireplace and the level of throttle opening lt Set temperature lt _ fireplace sensor readout T3 Firplace 1 30 73 Level of throttle opening It s a stable state that is in order to change it one need to press the CHOOSE button During appearing this screen one can change the set temperature of a fireplace 7 Firep parameter After pressing the CONFIRM button 5 the set temperature blinnks whose value can be altered with the buttons 2 or 4 To confirm the changes one needs to press CONFIRM once more If the manual mode is set Firp MOD MAN one can manually contro
7. d time zone Zone3 to 0 00 23 45 22 30 End of 3rd time zone PARAMETERS OF LEVEL 3 NAME RANGE FACTORY FUNCTION SETTING Ti Pause 10 60secg 20secs Rest time of the throttle between successive change of its position ModeOFF 0 100 0 Position of the throttle in the power off state 0 full closing 100 full opening Ti EndCH 1 30mins 4mins Pause time of CH pump in cyclical mode After the time the pump turns on for 45 secs ctr1 WAW 1 2 1 Kind of supply for the WAW accumulator 1 Temperature sensor T2 down controls the supply of WAW 2 Temperature sensors T1 up and T2 down control the supply of WAW accumulator T Alarm 75 95 C 85 C Fireplace temperature at which alarm turns on T FirOFF 5 25 C 10 C Decreasing fireplace temperature in relation to set temperature at whose exceeding the countdown of 30mins begins up to the switch off of fireplace stop condition at Firp MOD AUTO RelaySTR 1 6 1 Switch on of the relay CONTROL if 1 fireplace temperature is higher than T CH ON 2_ fireplace temperature is higher than T WAW ON 3 WAW temperature measured by T2 sensor is higher than T minWAW 4 WAW temperature measured by T1 sensor is higher than 1 minWAW 5 WAW temperature measured by T2 sensor is higher than T maxWAW 6 fireplace temperature is higher than T Alarm PARAMETERS OF LEVEL 4 NAME RANGE FACTORY FUNCTION Reset 0 1 0 Setting the value of 1 causes the recall of
8. he WAW circuit PRIO Faster reaching the readiness of WAW accumulator by limiting heat obtain by heating system The pump CH works cyclically Turning off the pump WAW after supplying the accumulator causes the comeback of normal operation of the pump CH CLOCK beyond time zones the pump operates like in the ON mode and in the time zone like PRIO Screen of clock CLOCK 1 17 15 The screen shows the actual time and the number of active time zone Time correction is possible after pressing the CONFIRM button 5 and the minutes field begins blinking The blinking value can be altered with the buttons or Pressing the CHOOSE button 3 one comes to the hours field that can be set with the buttons or Pressing the CONFIRM button confirms the changes the clock field will stop blinking 0 Normally the parameters setting level equals to 0 namely the parameters aren t available After changing the level to 1 2 or 3 successive screens show the values of parameters The last screen contains after which it comes back to the above mentioned screens Screen of setting the parameters 9
9. l the throttle the button 2 causes the opening ofthe throttle one step 10 and the button 4 causes its closing Screen of WAW temperature shows the actual temperature in the upper and lower part of the WAW accumulator WAW 80 lt Upper temperature sensor T1 if available 68 lt Lower temperature sensor T2 It s a stable state that is in order to change it one needs to press the CHOOSE button 7 Screen of whole system operation On the screen are the symbols of devices Firplace fireplace CH central heating system WAW Warm Applicable Water accumulator ifthe relay is switched on The symbols every few seconds or after pressing CHOOSE button are replaced with numbers presenting the temperatures of those devices The blinking arrows mean the actual heat flow as an effect of pumps operation Firplace gt WAW the pump P supplying the WAW accumulator is turned on Firplace gt CH the pump P3 is turned on lt CONTROL relay is turned on 80 lt upper sensor of WAW 73 68 lower sensor of WAW ji fireplace sensor Ifthe summer mode is active only WAW SUMMER replaces CH It s a stable screen that is in order to change it one needs to press the CHOOSE button Firp MOD AUTO ON The throttle is automatically controlled to stabilize temperature of the water jacket Green status lamp lights 7 Screen of fireplace operation mode There are the follo
10. ollowing standard 1SO9001 2000 CERTIFICATE No 133 2004 of 01 2004 Polish Foreign Trade Chamber The last two digits of the year in which the CE marking was affixed 07 Place of issue Manufacturer representative Wroclaw Miroslaw Zasepa Lassen l Date of issue Position 08 2007 Konstruktor 4 FRPLACE T3 pp TYE Fig 1b Operation configuration of the regulator with heat exchanger for the system CH pump of heat exchanger and system CH connected to output P3 T a a a b a e o a a o a Leet se eh EN SURE PAPERE E EE E TS Fig 1c Operation configuration of the regulator with heat exchanger for CH and WAW systems WAW Warm Applicable Water accumulator boiler FIRPLACE Water jacket fireplace CH Central heating system Tl Upper temperature sensor of WAW T2 Lower temperature sensor of WAW T3 Temperature sensor of fireplace water jacket P1 Pump supplying WAW from fireplace P2 Pump of the primary side of heat exchanger it operates if P1 and P3 are activated P3 Circulating pump CH PP Electronically controlled air throttle of fireplace 2 1 Air throttle operation The throttle regulates an air supply to the combustion chamber which allows the temperature of fireplace water jacket to be kept at set value The task is realized by comparing temperature T3 and set temperature T Firep parameter and then by gradual opening shutting the throttle The change of a throttle position takes place cyclically every
11. re sensor of WAW T2 shows temperature higher than 65 C T max WAW parameter The regulator realizes the after season rundown of the pump by switching it on for 1 min if it doesn t operate for a week 2 4 WAW priority and summer mode In the regulator one can set ModeWAW parameter achieving different strategies of operation Possible modes are OFF The pump WAW turned off SUMMER Turning off the heating system in summer time the pump CH doesn t operate Fireplace only works in the preparation function WAW ON Standard operation parallel operation of pumps without favouring the WAW circuit PRIO Faster reaching the readiness of WAW accumulator by limiting heat obtain by heating system The pump CH works cyclically Turning off the pump WAW after supplying the accumulator causes the comeback of normal operation of the pump CH CLOCK beyond time zones the pump operates like inthe ON mode and in time zone like PRIO 2 5 Output CONTROL The regulator is equipped with the relay CONTROL whose contacts can be used e g to switch off another heat source when a fireplace works The RelaySTR parameter defines the function of the relay more precisely see PARAMETERS of LEVEL 3 3 Service of the regulator There are elements on the control panel fig 2 In the turn off state only the orange lamp 7 lights indicating the standby mode The turn on of the regulator follows by pressing the ON OFF button 6 In order to
12. s 7 f IINTASe PRODUCENT ZASILACZY SIECIOWYCH ISO 9001 2000 CE CONFORMITY DECLARATION Ref No 58 RT 01 2007 1 B We ZAKLAD ELEKTRONICZNY TATAREK Jerzy Tatarek 75 Swieradowska St 50 559 Wroclaw declare under our sole responsibility that the product Regulator of heating system with solar collector model RT 08 RT 08K RT 08P is in conformity with the basic requirements included in Directive EMC 2004 108 WE of 15 12 2004 the electromagnetic compatibility law of 13 04 07 and Directive LVD 2006 95 WE of 21 08 07 Laws Journal of 2007 No 155 pos 1098 regarding the requirements for electric devices To the conformity evaluation the following harmonized standards were used PN EN 60730 2 1 2002 Automatic electric regulators for house usage and the like Part 2 1 Specific requirements regarding electric regulators for electric house devices PN EN 60730 1 2002 Automatic electric regulators for house usage and the like Part 1 General requirements PN EN 55022 2000 Electromagnetic compatibility EMC IT devices Characteristics of radioelectric noises Acceptable levels and measurement methods Complementary information Laboratory IASE 51 618 Wroclaw 1 Wystawowa st Test report No 39 DL 1 07 of 22 06 2007 41 DL 1 07 of 03 07 2007 Electronic Engineering Plant TATAREK has initiated management system and complies with the f
13. t at set value The task is realized by measuring temperature T3 and controlling the throttle PP properly Fireplace operation temperature is identified by the T Firep parameter see LEVEL PARAMETERS 1 If fireplace temperature T3 is higher than the 7 Firep parameter the throttle is gradually shut off limiting air supply and if temperature T3 is lower than the T Firep parameter the throttle is gradually opened up The second function is to control the pump P1 supplying the warm applicable water accumulator WAW The pump operates if fireplace temperature both exceeds the ON WAW value and is higher than the WAW accumulator temperature T2 by the DeltaWAW parameter see LEVEL PARAMETERS 1 The third function is to control the circulating pump P3 of central heating system The pump works if fireplace temperature exceeds the ON CH value It s possible to activate the WAW priority function see the description of operation modes of the pump CH The regulator is equipped with the clock to control the WAW priority in selected times of day l The fireplace can also be equipped with warm air distribution system based on the regulator RT 03C The regulator measures temperature in the chamber of a fireplace air ventilator and controls its rotation speed in manual or automatic mode Fig la Basic operation configuration of the regulator Admission date Realization date Signature Remark
14. the automatic change of the regulator operation at different times of day 24 hrs are divided into 3 time zones 1 2 3 and the single time when no zone is active that is ZONE 0 or BAZA BASE Each zone has a start time OD FROM and an end time DO TILL For the regulator factory settings are as it follows ZONE 1 FROM 6 00 TILL 8 00 ZONE 2 FROM 14 00 TILL 17 30 ZONE 3 FROM 20 00 TILL 22 30 6 Demonstration change of the Mode OFF parameter defining the throttle position in power off state parameter of level 3 Press repeatedly CHOOSE button till the Menu 0 parameter setting screen appears CONFIRM button gt 0 starts blinking threefold button gt 3 blinks CONFIRM button gt 3 stops blinking Parameters of level 3 were chosen CHOOSE button gt Ti Pause xx shows up The value of the 7i Pause parameter CHOOSE button gt ModeOFF shows up actual value CONFIRM button gt actual value to be changed begins blinking t gt setting a new value CONFIRM gt confirming the new value repeatedly CHOOSE button till the parameter end setting screen appears 4 Installing the regulator o o THE REGULATOR IS SUPPLIED BY 230V S50HZ ANY MOVES REGARDING INSTALLATION SHOULD BE MADE AT THE DISCONNECTED MAINS THE REGULATOR HAS TO BE CONNECTED TO THE MAINS WITH THE ZERO PIN THE RE
15. turn it off press once more the ON OFF button 6 and at the same time hold it down for about Isec In case of supply voltage decline the regulator comes back to the state before the decline The state is presented on the text display 1 The screens inform about the operation of devices temperature of sensors they make it possible to change the parameters etc The change of screen is done by pressing the CHOOSE button 3 If this is the screen that is able to change a parameter press the CONFIRM button which causes blinking of the parameter field to be changed By pressing 2 or 4 one can alter its value If there are more parameter fields on the screen e g setting the clock then one will go among them by pressing the CHOOSE button 3 By clicking the CONFIRM button 5 one confirms the changes the parameter field stops blinking The changed parameter not confirmed for 10 secs is not accepted by the regulator and it recalls a previous value of the parameter 5 wt ON OFF Kominek CONFIRM Fig 2 Control panel view Se SO ae Text display Increase button Choice button of parameter Decrease button Confirm button Power button Status lamp of the regulator emergency red standby orange operation green Lamp of pumps operation Lamp of throttle operation blinking means the overload of the drive 3 1 Time zones The regulator is equipped with the clock which enables
16. wing modes AUTO Automatic operation is activated by pressing the ON OFF button 6 The throttle is fully open In 2hrs a fireplace ought to heat itself and reach the set temperature stabilized by throttle movements From that moment the temperature fall by more than 10 C CT FirOFF parameter existing for 30mins is treated as a turn off of fireplace The regulator ends an operation cyclesetting the throttle at rest position Pressing the ON OFF button once more starts another operation cycle Green status lamp 7 lights during fireplace operation and turns off after recognizing the turn off state of fireplace OFF Setting the throttle at rest position defined by the ModeOFF parameter Green status lamp 7 doesn t light MAN _ Automatic control blocked only manual control is available Green status lamp 7 blinks It s a unstable state that is after 10secs from the last press of any button the screen changes to the screen of fireplace temperature measurement All the next screens are unstable Screen of WAW operation mode ModewAWw SUMMER In the regulator one can set ModeWAW parameter achieving different strategies of operation Possible modes are OFF The pump WAW turned off SUMMER Turning off the heating system in summer time the pump CH doesn t operate Fireplace only works in the preparation function WAW ON Standard operation parallel operation of pumps without favouring t