WIRING DIAGRAM 3-phase, 2-phase, 1-phase

image

Contents

1. FA I Sub WVoofer A T OOOO Antenna e LN EEA Pra A ee A i DVDIPOWER Ce EN 5 SA es et a f to FX TEMFERATURE a fd 4 fd 4 SENSOR LAMP LED WATER LEVEL l JOD Q Oo meen e UP DOWN HEATER FECGCLEPUMP BUBBLE ACGNINPUT AATERPUME WATERPUMP2 WATER PUMPI LIMIT SWITCH MOTOR WIRING DIAGRAM 3 phase 2 phase 1 phase i connecting LI LI L3 NE 2 connecting LI LI N E only 3 connecting L N E only L L 380k L N 230V 330V L L 380h L N 320r 2301 L N 330 F230 F Figure 1 l USER MANUAL for the SG 0007B SYSTEM II Operating instructions R Fig 2 e ON OFF key power key Connect the power supply and press the ON OFF key All the control systems are now ready to run indicator light is on and the circulation and Ozone disinfection system if one exists will start working automatically if the water temperature is not at the pre set temperature the heating system will start to work in 60 seconds The panel will display the circulation and Ozone symbols a symbol for the heating system will also be displayed o1 yanel if the heating system is working The panel will also display the detected water temperature Note If no button is pressed within 60 seconds the displays backlight goes off it reactivates if a button is pressed e PUMP key press the JET1 key Its symbol will now appear on the panel signifying that massage pump 1 has been activated JET2 and JET3 work in the same way and hav
2. USER MANUAL for the SG 0007B SYSTEM This product is meant to be used for electronic control of functions for spa baths Please read all of the instructions carefully before enjoying the spa WARNING Operating the system without water will cause severe damage Contains electronic components shock hazard Does not contain user serviceable parts Do not try to repair the control unit Contact your dealer or service center for help Follow all user instructions I Installation 1 Open the door cover according to the instructions and connect the power supply correctly Warning A Installation is only to be made by qualified persons B Read the instructions carefully before beginning the installation C We are not responsible if the product does not work or is damaged when the instructions are not followed during installation D Ensure that the system is not damaged during transportation when it is unpacked Note A 1x 16A Read Interlocked system between the heater and pumps 2 x 16A or 3 x 16 should be connected to the control system Do not connect the power before the installation 1s complete B Install a maintenance switch close to the control system for use during maintenance work C An earth switch must be installed Check that the earth switch works when the power is connected SG0007B Sketch Of Linking Wires For The System C OZONIZER X B as g O me s O CDANPUT aLr Ni ie i mm fil i il i i
3. e circulation pump starts and runs for 1 hour the display panel will cycle between ON and water temperature indicator key 1 will light up After 1 hour the pump will stop for 3 hours the display panel will cycle between OFF and water temperature indicator key 2 will light up As long as the system is in automatic mode this filtration cycle will repeat indefinitely The keys 1 2 and 3 FILTER PROGRAM are non functional keys and only act as indicators NOTE gt If the spa is in automatic working mode please don t turn off the spa when not in use Make sure the spa is always on gt When in automatic mode the filtration pump will also be controlled by temperature If the water temperature is lower than the preset level during the OFF period the filtration pump and heater will work until the water temperature has reached the preset level Then the filtration pump will return to work for 1 hour and stop for 3 hours repeatedly When the automatic mode is not in use the circulation pump is always on If the water temperature drops 2 under the pre set level the heater will activate gt Each time the spa is switched on the system will go into the previously set mode Press and hold the or key for 3 seconds the indicator will show GREEN to switch between automatic mode and manual mode Summary and If is selected the filtration is handled automatically in cycles of 1 hour on 3 hours off I
4. e their own symbols with numbers 2 and 3 on them JET1 JET2 AND JET3 are accessories for some spa models NOTE The massage system will shut down automatically in 20 minutes NOTE There are some air valves on the topside of spas near the seats They are to control the strength of the hydro massage in the respective seats e BUBBLE key Press the key Its symbol will appear on the panel meaning that the air massage system has started working NOTE The blower automatically shuts down after 20 minutes e 03 key Ozone Pressing the O3 key will turn on or off the Ozone disinfection system Ozone and circulation pump work automatically when activating the spa NOTE Ozone can be an accessory and another alternative is the UV C ozone cleaner See UV C Ozone Cleaner under Summary e LAMP key When the control systems are ready to work first press the key Its symbol will now appear on the panel signifying that the underwater lights are on the colour will change automatically with a second press the color will be fixed on a certain color press for the third time to shut it off NOTE The lamp shuts off automatically after 60 minutes e TEMP key needs to be used together with A V key If the TEMP key is pressed for 5 seconds the panel will display the water temperature set last time This temperature will keep flashing Press the A key to adjust the temperature to the highest at 42 press the Y key to adjust the temperature
5. f is selected the filtration pump and thus the filtration is on continuously 24h per day without stopping in between If the preset temperature is higher than the actual water temperature then both the circulation pump and heater are activated until the water temperature reaches the chosen setting The Ozone will automatically work together with the filtration pump and heater This applies in both and modes WARNING The circulation pump also generates heat and 1f it is running a long time eg continuous filtration TM it can raise the temperature by several degrees in one day when the tub is well insulated Avoid using the TM function other times than when the water needs to be filtered further Always check water quality and temperature after using TM for one day FILTRATION PUMP NOTE If the hot tub is equiped with a massage pump it will connected to WATER PUMP 1 If there are two massage pumps the second is connected to WATER PUMP 2 UV C OZONE CLEANER If an UV C ozoner cleaner is installed connect it so that it activates the same time as the circulatory pump BLOWER BUBBLE ATTENTION If the blower is used often and for prolonged periods of time the blowers built in thermal protection might activate The blower will stop and not restart until it s cooled down enough You can speed up the cooling by opening the service hatch es In doing so please protect the equipment from potential freezing damage 4
6. n to enter standby status the indicator light on ON OFF key flashes the anti freezing system will be activated instantly The circulation pump and heating system will automatically stop at the default temperature of above 10 When the water temperature in the spa drops below 9 the circulation pump heater and air blower will work automatically Jet accessory will automatically start to work in about 85 seconds and it will stop after working about 85 seconds then Jet2 af equipped will start to work for about 85 seconds and stop finally Jet3 starts to work if equipped for about 85 seconds then stops Pumpl Pump2 and Pump3 will continuously cycle among themselves When the detected water temperature reaches 10 all the pumps and heater will stop working When this system is running the screen background light is on When the water temperature reaches 10 the screen returns to the standby status USER MANUAL for the SG 0007B SYSTEM Manual working mode Turn on the spa then press and hold the key for 3 seconds to enter manual mode the indicator light on the key will show GREEN when in manual mode indicator key 3 will light up If is selected the filtration pump and thus the filtration is on continuously 24h per day without stopping in between Automatic working mode Automatic working mode is on by default Press and hold the key for 3 seconds to switch over to automatic mode The button will light up Th
7. o select pre stored radio stations the panel will automatically show the previous radio frequency after you stop adjusting for 3 seconds With a long press for 5 seconds the system will automatically search for radio frequencies again and store the searched frequencies at a different channel sequentially Heating system After the control systems are ready to work the heater will start working 60 seconds after the circulation pump is activated unless the temperature sensor detects that the set temperature is lower than the detected one When the water temperature reaches a set temperature the heater will stop working automatically When the water temperature is under 2 of the preset one the heater will reactivate The symbol for the heater is located above the circulation pump symbol it appears as pulsing bubbles NOTE The heater will not be activated if there is not enough water flow Interlocked system between the heater and pumps Pressing and holding the ON OFF key again for 20 seconds will change the system between interlock mode or non interlock mode the indicator light on the ON OFF key shows RED in interlock mode while it shows GREEN in non interlock mode When in interlock mode the heater will stop when you press any of the pump and bubble keys This feature is meant to reduce the power needed for the spa so that it can match the power limit of some countries 1 x 16A In non interlocked mode the heater will keep running when
8. the other pumps are activated unless the water temperature reaches the set temperature NOTE That requires at least a 2 phase connection if the total effect for pumps and heating exceeds 3680 W Temperature sensor self checking system If El is displayed on the panel then the temperature sensor is disconnected In this situation check the wiring of the temperature sensor to see if it s properly connected If EO is displayed on the panel then the temperature sensor has short circuited In this case the temperature sensor must be replaced The heating system cannot be activated under the two above situations Water lacking protection system for circulation pump and heater In daily usage a blockage of the filtration medium cartridge filter or filter bag will eventually occur A severe blockage will lead to a lack of water for the filtration pump Air in the system often leads to the same problem For instance during startup if aeration has not been performed according to the instructions in the manual When there is a lack of water the filtration pump and heater will stop working automatically At this moment the symbol of the filtration pump on the control panel will flash continuously to remind the user that it is time to clean or replace the filtration medium After cleaning or replacing the filtration medium press ON OFF several times to expel the air inside the pipe until the filtration pump works normally Anti freezing system After power o
9. to the lowest at 10 The new temperature will be automatically stored and the display will then return to show the current water temperature after flashing for 60 seconds or if the or button is used e RADIO AV key Radio DVD Control and display of temperature When the control systems are ready to work press the RADIO AV key to activate the Radio function The panel will now show the radio channel set last time under Radio status press key to select pre stored radio stations a second press will activate the TV function this function is optional The panel will now show a TV symbol A third press will activate the DVD function this 2 USER MANUAL for the SG 0007B SYSTEM function is optional The panel now shows a DVD symbol at the same time Under DVD status press the key to adjust the volume of the DVD Press for the fourth time to show the detected water temperature TUN VOL key needs to be used together with the key Under Radio status first press the TUN VOL key The panel will now show a 2 digit volume pressing will adjust the volume upwards or downwards the panel will automatically show the radio frequency when you stop adjusting for 3 seconds With a second press the current frequency will flash Pressing the key will adjust the current frequency This frequency will be stored automatically after flashing for 3 seconds With a third press the panel will show the radio channel Press the key t