Home
User manual MiniLift125 EN
Contents
1. e Lifting assistive devices for manual and mechanical lifting of users Improved work environment improved quality of care and cost savings The philosophy behind SystemRoMedic is focused on the prevention and reduction of occupational injuries while allowing users to experience a greater sense of independence and dignity Through a unique combination of training and a complete range of efficient transfer aids SystemRoMedic offers improvement of both work environment and quality of care and at the same time achieves significant cost savings Always make sure that you have the correct version of the manual The most recent version of all manuals are available for downloading at from our website www handicare com For questions about the product and its use Please contact your local Handicare and SystemRoMedic representative A complete list of all our partners with their contact details can be found on our website www handicare com Handicare offers solutions and support to increase the independence of disabled or elderly people as well as to improve the convenience of those who are caring for them The Handicare Group is one of the leading healthcare companies in Europe with its own manufacturing organizations and sales companies in Norway Sweden Denmark Germany the Netherlands Great Britain France China Canada and the USA Handicare s products are also distributed by partners in more than 40 countries worldwide Our wide ra
2. 6 buttons with service battery status and overload indicators article no 7O200089 I llle SystemRoMedic MANUAL 1i Maintenance The lift must undergo thorough inspection at least once per year Inspection must be performed by authorized personnel and in accordance with Handicare s service manual Repairs and maintenance may only be done by authorized personnel using original spare parts X Spent batteries are to be left at the nearest recycling station Spent batteries can also be returned to Handicare or a Handicare dealer for recycling Cleaning disinfection Clean the lift with warm water or rubbing alcohol and ensure that the castor wheels are free of dirt and hair Do not use cleaning agents containing phenol or chlorine as this may damage the material Storage and transportation If the lift is not to be used for some time or e g during transport we recommend that the emergency stop button be pressed in The lift should be transported and stored in 10 C to 50 C and in normal humidity 30 75 The air pressure should be between 700 and 1060 hPa Let the lift reach room temperature before the batteries are charged or the lift is used 1060 hPa 15 50 C ae 700 hPa 30 Service agreements Handicare offers the possibility of service agreements for maintenance and regular testing of your mobile lift Contact your local Handicare representative 12 MANUAL SystemRoMedic Symbols
3. Read user manual May not be discarded in domestic waste The product complies with the requirements of the Medical Devices Directive 93 42 EEC Type B according to the degree of protection against electric shock The device is intended for indoor use Class Il equipment Always Read The User Manual EMC This equipment system is intended for use by healthcare professionals only This equipment system may cause radio interference or may disrupt the operation of nearby equipment It may be necessary to take mitigation measures Such as reorienting or relocating the equipment system or shielding the location SystemRoMedic MANUAL 13 Technical Information Lifting speed 35 mm s without load Batteries Two 12V 2 9 Ah valve regulated sealed lead accumulator gel type batteries Max 400mA Motor mast DC 24 V 10 5 Ah Operating time 10 maximum continuous operation for 2 minutes Push 7500N Motor base DC 24 V 12 3 Ah Operating time 10 maximum continuous operation for 2 minutes Push 1000N Operating forces buttons on 4N hand control Max load 125 kg 275 Ibs Medical Device Class The product complies with the requirements of the Medical Devices Directive 93 42 EEC 14 MANUAL SystemRoMedic Dimensions All measurement are in mm 5mm 0 2 GY TT Tt Ae I Length base Inside base min Inside base max Outside base min Outside base max Height Height base Clear
4. ce MiniLift125 TOA S SystemRoMedic 400641434 E ab mb ae SWL 125 kg 275 Ibs H handicare Manual nr 884 En Ver 5 150305 Table of contents Assembly of MiniLift125 Final inspection Using the product Important information Safe working load The control box and battery have the following features Charging batteries Hand control Emergency stop Emergency lowering Instructions for use Using MiniLift125 Trouble shooting Accessories Maintenance Technical information Dimensions 10 10 11 12 13 MANUAL SystemRoMedic MiniLift125 SystemRoMedic 1 Lift arm 2 Hooks for lift vest sling 3 Hand control 4 Leg support 5 Footplate 6 Rear castor wheels with brakes Battery 8 Emergency stop 9 Adjustment of leg support 10 Manual emergency lowering 11 Electrical emergency lowering 12 Charging lamp 13 Locking mechanism for adjustment of lift arm 14 Handles 15 Front castors MiniLift125 is a mobile sit to stand lift which has been developed to as gently as possible assist the user when rising from a sitting to a standing position When MiniLift125 is combined with the appropriate lifting accessories the user gets support under the feet for the front of the lower legs and behind the back which provides for a safe and secure sit to stand procedure To be able to understand how comfortable Mi
5. ction on charging batteries Keep the manual where it is accessible to users of the product SystemRoMedic MANUAL Using the product A Important Information e The lift must be assembled according to the instructions provided by Handicare e The lift may only be used on a level floor e Lifting accessories must be properly fitted and tested in relation to the user s needs and functional ability e Under no circumstances may the safe working load be exceeded See section on Technical information and the product label on the lift e Never move the lift by pulling on the actuator De e The lift must not be used or immersed in or under water including showering e The lift should not be left stored in a high humidity environment e The lift must not be charged in a wet room e To ensure optimal function the lift must be inspected regularly See section on other maintenance details e Warranty applies only if repairs or alterations are made to the product by personnel who are authorized by Handicare e Using lifting accessories other than those approved can entail a risk Safe working load Different products on the same lift system lift unit lifting sling and other lifting accessories may have different allowable safe working loads The lowest allowable safe working load always determines the safe working load of the assembled system Always check the safe working loads for the lift and accessories before use Contact your
6. dealer if you have any questions 6 MANUAL SystemRoMedic The control box and battery have the following features Emergency stop Charging lamps Display showing battery charge level Charger cable Connection for base width adjustment motor Connection for lift arm actuator Connection for hand control Electrical emergency lowering Handle for lifting battery Sern oOo Pe Nh gt Charging batteries A tone when using the lift indicating that the batteries need recharging Charge the lift after use to ensure that the battery is always fully charged Lock the castor wheels when charging the battery 1 Connect the charging cable to a power outlet 2 Check to ensure that the lamps on the control box light up The green LED lamp indicates that the charger is receiving power and the yellow LED lamp indicates that the battery is charging 3 Charging stops automatically when the battery is fully charged Wall mounted charger 1 Remove the battery pack from the lift and place it in the wall mounted charger 2 Check to ensure that the LED lamp on the front of the charger lights up NOTE Before the lift is used for the first time it must be charged for at least 4 hours For maximum battery life charge batteries regularly We recommend daily charging when the lift is used daily If the emergency stop is active then the lift can not be charged SystemRoMedic MANUAL ig Hand control Raising lowering the
7. e lift to the desired height and ensure that the user is standing with both feet on the footplate and is grasping the sling bar handles with both hands to avoid being pinched between the sling bar and lift loops Helpful hint Use a longer loop alternative for short users and for users that cannot be fully raised Use a longer loop alternative for taller users and pull the lift arm out to allow the user to rise to a standing position MANUAL SystemRoMedic Trouble shooting If the lift or base width adjustment cannot be activated check the following That the emergency stop funktion is activated That all cables are properly and securely connected Pull out the contact and plug it in again firmly That battery charging is not in progress That the battery is charged If the lift is not working properly contact your dealer If the lift makes unusual noises Try to determine the source of the sound Take the lift out of operation and contact your dealer Accessories ThoraxSling polyester XS XXL article no 45500003 009 ThoraxSling wipeable S XXL article no 45500004 009 ThoraxSling with seat support polyester S XL article no 45600004 008 ThoraxSling with seat support disposable non woven S XL article no 45690004 008 CalfStrap article no 70200033 SlingBarWrap MiniLift wipeable article no 70200012 For MiniLift160EE 60300012 600300013 pies Hand control HB33 6
8. ence at base Lift height min Lift height max Footplate height Footplate clearence Inside space between bars Total length Safe working load Total weight Weight loose parts Foot plate Number of lifts per charge Footplate measurement 870 mm 445 mm 745 mm 600 mm 890 mm 995 mm 125 mm 95 mm 880 mm 1410 mm 50 mm 30 mm 450 mm 900 mm 125 kg 39 kg 5 kg 20 25 390 x 345 mm 34 4 175 29 3 23 0 35 39 1 4 9 or 34 6 55 5 1 9 dal 17 7 35 4 275 5 Ibs 85 9 lbs 11 Ibs 15 3 x 13 5 SystemRoMedic MANUAL 15 SystemRoMedic Simple solutions for great results SystemRoMedic is the name of Handicare s unique easy transfer concept the market s widest and most comprehensive range of clever easy to use and safe transfer and lifting aids designed to make life easier both for the user and for the caregiver SystemRoMedic is a complete solution that provides for the majority of patient transfer or manual handling requirements From the simplest to the most complex scenarios from the lightest to the heaviest The concept encompasses assistive devices for four different categories of transfers e Transfer assistive devices for manual transfers of users between two locations Positioning assistive devices for manual repositioning of users within the same location e Support assistive devices for mobility support e g during sit to stand or gait training
9. fting the user The width of the base must be correctly adjusted to ensure optimal safety NOTE MiniLift125 is not intended for transporting users It may only be used for short transfers Caution Never move the lift by pulling on the actuator Caution Ensure that the user s feet do not get caught between the footplate and the floor Ensure that the user s feet do not get caught between the footplate and the base when adjusting the base width SystemRoMedic MANUAL Using MiniLift125 Place an appropriately sized ThoraxSling behind and below the user s hips see manual for ThoraxSling When the user has placed his her feet on the footplate move the lift for ward towards the user Place the lift as close as possible to the user Take care to ensure that the user s shins are resting securely against the leg support and then adjust the leg support so that it does not press against the user s kneecaps about 2 cm lower Raise the locking handle on the lift arm 2 and pull the lift arm out as far as possible towards the user Select the sling loop that reaches the hook on the lift arm Shortest loop alternative Hook the lift loops to the underside of the slingbar Raise the locking handle and draw the boom back so that the lift straps on the sling are stretched and then lower the locking handle back into position Instruct the user to allow himself herself to be supported behind the back during raising Raise th
10. lift arm 4 a Symbol indicate direction of travel Motion stops as soon as the button is released Markings on the buttons indicate function Widening narrowing the base i m Motion stops as soon as the buttons are released Emergency stop To activate emergency stop Press the red emergency stop button on the control box Resetting Turn the button in the direction of the arrows until the button pops out Emergency lowering Manual emergency lowering Manual emergency Lift the red regulator upward lowering Electrical emergency lowering For electrical emergency use the down button on the control box Use a narrow object such as a pen Electrical emergency lowering 8 MANUAL SystemRoMedic Instructions for use These instructions must be followed for correct use of MiniLift125 Caution The actuator does not lower the lift arm when the lift is being lowered This reduces the risk of the user being pinched by the lift arm but as a result the lift arm may at first catch and then suddenly fall To prevent this the lift arm must be loaded throughout the entire lowering procedure so that it is always supported by the actuator Hand control functions The hand control has four functions up and down lift arm out and in base width Two functions cannot be used at the same time NOTE The hand control functions do not operate if the emergency stop button is activated Transferring and li
11. nge of high quality products includes various manual and power wheelchairs seating systems scooters a complete easy transfer system and other patient handling aids stairlifts car adaptations rise and recline chairs and bathing and toileting products handicare Handicare AB Maskinvagen 17 SE 972 54 Lulea SWEDEN Tel 46 0 8 557 62 200 Fax 46 0 8 557 62 299 E mail info handicare se www handicare com Handicare AB is quality and environmentcertified in accordance with ISO 9001 IS014001 and ISO 3485
12. niLift125 is compared with other sit to stand devices on the market it must be tried The construction safely moves the user forwards and upwards in a natural movement pattern and at the same time the leg muscles and balance is exercised e Functional inspection Visual inspection Inspect lift functions regularly Check to ensure that material is free from damage Before use Ensure that the product is correctly assembled Check slingbar connection and safety latch function Check lift and base width movement Check to ensure that the actuator is correctly installed li Always read the user manual Always read the user manuals for all assistive devices used during a transfer Keep the user manual where it is accessible to users of the product The lift may only be used by persons who have received instruction in the operation of the lift SystemRoMedic MANUAL 3 Assembly of MiniLift125 Check to ensure that all components are included Lift motor control box battery pack base with motor footplate hand control and cord manual and charging cable Screws and screw covers should also be included see below Assembly Place the upper section on the lower section and lower it carefully into place picture 1 Press it fully into place and tighten all four screws Finally place the plastic covers over the screws picture 2 Mount the footplate on the crossbar and then lower it picture 3 Mount the leg s
13. upport by inserting the crossbars on the back into the fixtures on the lift 4 and then tighten Connect cables Hand control cord in HS cable for lift unit on mast in outlet M1 and cable for base width motor in outlet M2 5 4 MANUAL SystemRoMedic Final inspection Check to ensure that no parts have been left in the packaging Inspect the lift for signs of wear and damage Check all four castor wheels and castor wheel locks Check all connections and fixtures including screws and bolts Check the emergency stop function by activating the emergency stop and then pressing either the up or down button If nothing happens when the up or down buttons are pressed the emergency stop is functioning properly Grasp the hand control press the up button and run the lift arm all the way up Then press the down button and run the lift arm all the way down Test base width adjustment function Press the button for base width adjustment to widen the base fully and then press the other button to narrow the base again Test lift function by lifting a person not a user using an approved sling At the same time check the emergency lowering function with someone on the lift See section on Emergency lowering If the lift is functioning correctly connect the charger and check to ensure that the charging lamp on the control box lights up NOTE Before the lift is used for the first time it must be charged for at least 4 hours See se