1. foot pedal can be cleaned with moist wipes 9 Power supply Cord aN Electrical Plug to Power Station The power supply supplies electrical power to the control unit Connect the power supply connector to the control unit Connect the handle cable to the control unit Connect the power supply to the mains supply When connected to power the control unit s LEDs blinks Note Make sure the power supply cable is free of foreign objects Specialized Training Training is done only by authorized NPM training guide Training includes System operation Troubleshooting Permanent makeup techniques An NPM course completion certificate is given after successfully completing the course 10 Warranty Warning Do not use or operate the unit without proper training Repairs Only NPM technicians are authorized to repair the unit Do not attempt repairing the unit yourself Packaging The unit and accessories are supplied in a specially designed case The unit is labeled with a serial number Warranty Warranty period is 24 months from day of purchase please keep all purchase documentation Printed warranty card is supplied with the unit Make sure it is included in the unit s documentation The warranty card includes the following information e NPM company information e Serial number e Purchase date e Customer information Warranty is void in case the unit is not in its original casing and or without a seri
2. ORV AIN 56 Permanent makeup device The ORON 56 is a permanent makeup device based on Dermo pigmentation insertion of pigments using a proprietary needle User Manual Hardware Revision REVOO Firmware Revision REVO1 NEI INTERNATIONAL New Permanent Makeup Technologies Table of Contents Content Page BOVO E AN eee E 3 Geno Sanedrin en EEEE EEE AA E conneenheaeaatuceatate 3 4 Main p we f SUDDIY occ smcetetectncimeiciiewadwinntniaiotiniinieeceiaivinetietunnbeieiedinaes 5 6 DAN Nea E E E T E EE E E T E 6 7 Integrated Needle Head cccccccssessseeeeceeneesseeeeeessenssseeeeeesseeeneneees 7 FS Cle EAE EE AE EE E EAR E NEN E E 8 ORO UN e A E EA E E 9 Training repair packaging and warranty 0 ccceeeeeeeeeeeeeeeeeeeteeeeeeees 9 General information and troubleshooting 10 SS TI AE ON crise depos nce E 10 Technical INTONMAL OM we s cinwsnavrnvensceanetneecsnvdsseanvoiextsdncsansendane tanensinee rreren 10 E DO cst A E steroniaustembeninesa ty 10 MaMe NaNO e causal aun senna mieiaaianenteadent 10 Control Unit and Parts Power Station Power Supply H and piece Pedal Head for Needle Device parts Control unit m Power supply Activation foot pedal m Handle needle holder assembly Control unit Handle Position Decrease Speed Speed Display Increase Electronic Ciruit _Speed _ Handle Numerical display Displays On Off device sp
3. al number Unit transportation only in its original case Use only NPM parts Do not use and needles other then NPM s Troubleshooting If the device fails to operate Make sure all cables are properly connected Make sure it is properly connected to the mains supply and the Display LEDs are blinking Make sure the POWER and Piece LEDs are on Make sure the needle is connected Make sure the foot pedal is activated 11 Service For Repair services call 972 4 8702206 or e mail us at sales npm co il Do not attempt repairing the device yourself Classification The unit is classified as Class 1 Continues use portable Do not use near flammable material Storage and operational environmental conditions 10 40 degrees centigrade 30 75 relative humidity 700 1060 hPa atmospheric pressure Warning Read instructions before use Not reusable Dispose of properly Cleaning and sterilization Use moist wipes to clean all working areas Alcohol use is permitted Use disposable gloves A Warning Please read instructions 3 Not for reuse BF applied part Wish you al Manufacturer name Successful performance i NPM Ltd Do not dispose WWW NPM INTERNATIONAL COM
4. d the handle base in your left hand needle pointing up Turning the needle holder clockwise will increase needle height Turning the needle holder counter clockwise will decrease needle height The unit is now ready for permanent makeup implementation Control Unit Weight 915 grams 4 Speed display The speed display range is 100 200 To increase speed press the key To decrase speed press the key Speed control keys Press the POWER key ALED light above the key indicated control unit power status PIECE key enables handle activation by pressing the foot pedal Device Parts Pen Cord Needle Position Hand piece The pen is used to hold the permanent makeup needle It is connected to the control unit via a cable Cable length 180 cm Pen weight 88 grams The PIECE LED light indicates the unit s power status 1 Needle holder 2 Power supply connector 3 Power supply cable 4 The pen is constructed from two parts Pen base and needle base The needle base can be sterilized disconnect from handle base by rotating counter clockwise Note While not in use keep the handle in a plastic wrap Clean the handle gently using moistened wipes Integral needle Insert area Needle Head Locking Mechanism Connecting the needle Use disposable gloves Make sure the ORON 56 control unit is powered off Take the needle out of the sterile packaging make sure th
5. e package is not damaged prior to opening it if it is do not use it Insert needle into the handle needle base Rotate the needle a quarter turn clockwise to lock it in place Activate the handle by pressing the foot pedal After treatment Make sure the ORON 56 control unit is powered off Turn the needle a quarter turn counter clockwise and pull it out of the needle base Dispose of the needle properly Place the handle back into the control unit Warning The ORON 56 device can only be used by NPM authorized and trained staff 8 Foot pedal Cord Connector to Power Station Pressing on the foot pedal activates the handle motor The foot pedal is connected to the control unit via a cable 180cm long Activating the foot pedal Make sure the foot pedal connector is securely connected to the control unit Press the foot pedal to activate the unit Release the foot pedal to deactivate the unit A second option is available for those who don t want to use a foot pedal a silver connector is available to connect instead of the foot pedal This connector will activate the hand piece automatically as soon as you press the piece button Press one time to start and a second time to stop activation Warning Do not place any objects on the foot pedal Make sure the foot pedal location is completely dry To keep the foot pedal clean it is recommended to wrap it with plastic or plastic bag f needed the
6. eed m Piece key Activities Deactivates power to the Handle Power On Off Power key Turns the control unit On or Off Model Name m Electronic circuit Displays Device Status On Activity Control unit Connectors p VDC Control unit Connectors m 12VDC Power supply input Power Connector m PIECE Handle Cable input PEDAL Foot Pedal Cable input Handle Connector Pedal Connector 4 Getting Started Before using the ORON 56 Device please follow the next steps Wear disposable gloves Make sure all cables are securely connected Power the base unit On and activate the Piece ORON 56 Power on Press the Power key Press the Piece key Press the foot pedal the foot pedal is momentary action based It will stop the Piece activation as soon as it is released ORON 56 Power off Release the foot pedal Press the Piece key Press the Power key Place the handle back into the control unit base Preparing the device for usage Connect the handle cable to the control unit connector labeled PIECE Connect the foot pedal to the control unit connector labeled PEDAL Connect the power supply cable to the control unit connector labeled 12VDC Press the POWER key Press the PIECE key Select the integral needle suitable for the treatment Place the needle in the handle head and rotate quarter turn clockwise to lock the needle in position Press the foot pedal To adjust needle position hol

Download Pdf Manuals

image

Related Search

Related Contents

45 & 60  Westinghouse 1080P User Guide  D-Link DHP-308AV/E  Samsung CDUCT CAC AC with Easy to Maintain, 18 kW User Manual  LEYBOLD DIDACTIC GMBH Mode d`emploi 562 801 Instrucciones  Mounting and Operating Instructions EB 5571 EN  HP Deskjet 450 series User's Manual  User Manual  Manual - RayBiotech, Inc.  Guía de instalación rápida I NS-HDRAD HD Radio™ para  