1. Non active alarm Normally opened O Maximum alarm Normally closed O Maximum alarm Window alarm Regulation T N low reverse heat Regulation T N high direct cold Regulation T N symmetric reverse heat Regulation T N symmetric direct cold an Change value x a SU Sas III ent S eremo gt ln al I L aL n Communication Modbus Modbus Communication address omnia High speed NoRxandTx Standard TEL Receive messages not forhim Addresses of the oO Low speed SE me LAnswer communications cr LiL Receive message with CRC error ce L EF LIM Receive message with wrong command LI J ll I I um r tacki WI I rae rae eo LI JI LI Lo Di EE ES Z gt r tee A 5 L L 1 a Output Output Output minimum limit maximum limit measured in error No output Orr value Change value Change value om V O 4 20 mA gt When the measure shows Err this value is generated n n cm CITI The communications channel operates with RS485 wiring Protocol is ModBus RTU Example of connection Connection of a network of devices to a PC usi m x 1000 m af RS 485 Conversion options DLO1 CPU CP970 ir DLO1 CPU CP970 de 45 En 15 ea z Heg ya i f SILA ul f DE de ANA El HA ai PC Connector Sub D 9 p
2. ALARM SET 3 AL 3 HYSTERESIS ALARM 3 AL 3 32767 32768 32767 32768 32767 32768 32767 32768 32767 32768 32767 32768 READ STATUS ALARM 1 AL 1 READ STATUS ALARM 2 AL 2 READ STATUS ALARM 3 AL 3 READ STATUS OUTPUT 1 DO 1 READ STATUS OUTPUT 2 DO 2 READ STATUS OUTPUT 3 DO 3 WRITE STATUS OUTPUT 1 DO 1 remote mode WRITE STATUS OUTPUT 2 DO 2 remote mode WRITE STATUS OUTPUT 3 DO 2 remote mode STATUS DIGITAL INPUT 1 DI 1 STATUS DIGITAL INPUT 2 DI 2 STATUS DIGITAL INPUT 3 DI3 Bit Bit Bit Bit Bit Bit 30001 BIT 9 3001 9 30001 BIT 10 30001 10 30001 BIT 11 30001 11 30002 BIT 2 30002 2 30002 BIT 3 30002 3 30002 BIT 4 30002 4 40095 BIT 0 40095 0 40095 BIT 1 40095 1 40095 BIT 2 40095 2 30001 BIT5 30001 5 30001 BIT 6 30001 6 30001 BIT 7 30001 7 QOFF 1 ON 00FF 1 ON 00FF 1 ON 0 OFF 1 ON 0 OFF 1 ON 0 OFF 1 ON QOFF 1 ON 00FF 1 ON 00FF 1 ON 0 OFF 1 ON 0 OFF 1 ON 0 OFF 1 ON Only Read Only Read Only Read Only Read Only Read Only Read Read Write Read Write Read Write Only Read Only Read Only Read The Modbus registers with format 300xx are reading adresses They belong the the command 3 Modbus which allow a reading up to a maximum of 9 Modbusregisters per reading The Modbus registers with format 400xx are reading writing adresses They belong the the command 16 Modbus which allow a reading up to a maximum of 3 Modbus registers per reading The Modbus registers are
3. or 2 common ground Type siria mA V with external shunt Resolution cara 13 bits Output ranges 0 4 20 mA Precision at 25 Gi 0 2 Refresh time 250 ms Digitals outputs Relays SPST NA Isolation Output auxiliary voltage Output 1 sana 18 VDC no stabilised Maximum output current 50 mA Isolation Output 2 opt 5 VDC stabilised opt Maximum output current 20 mA Isolation 500 V except with analog output Communications pra RS 485 A e Modbus RTU Speed 9600 19200 38400 bauds Operation limits Ambient temperature 0 a 50 C Storage temperature 20 a 70 C Relative humidity max 85 HR without condensation Directive CE Emmision Inmunity EN 50081 EN 61000 Supply and consumption Voltage 60 250 VAC amp 22 250 VDC 20 60 VAC option ISOIAHONE u ee 500 V Frequency eier 50 60 Hz Maximum load _ 500 Q GONSUMPIONE iii 2 VA DATATYPE MODBUSREGISTER LIMITS MODE Wordwith sign 30011 Only Read Word with sign 40035 Read Write Word with sign 40036 Read Write Word with sign 40038 Read Write Word with sign 40039 Read Write Word with sign 40041 Read Write Word with sign 40042 Read Write CONCEPT MEASURE Alt ALARM SET 1 AL 1 HYSTERESIS ALARM 1 AL 1 ALARM SET 2 AL 2 HYSTERESIS ALARM 2 AL 2
4. showed in decimal www disibeint com disibeint disibeint com Segle XX 91 E08032 Barcelona DISIBEINT T 34 934 330 370 ELECTRONIC SL n 34 934 354 532 DISIBEINT reserves the right to alter this document wiwhout previous notice DISIBEINT ELECTRONIC SL ue Segle XX 91 E08032 Barcelona T 34 934 560 995 F 34 934 354 532 www disibeint com disibeint disibeint com
5. User s manual Programmable panel meter IPD Wall assembly Window of 46 x 915 mm 2 5 x 3 5 Made with ABS UL94 HB The equipments must not be placed in environments too near to power elements such us circuit breakers triacs rectifier bridges high voltage transformers etc As far as possible the equipments will be isolated from the emitters of electrical disturbances by means of for instance a shield connected to ground The equipments will not be exposed to extreme temperatures and humidities Maximum room temperature for optimal operation 40 C Maximum room humidity without precipitation 90 The connections must be done separating phisically the measurement signals from the control or power signals Do not use the same connection for the power supply of the equipment and for the control line of the circuit breakers motors etc In a general way it is recommended to use an exclusive supply line for the equipments connected directly from the main and provided with the appropiate protections If this is not possible install an isolation transformer with the shield connected to ground Before applying the supply voltage or the signals be sure that the wiring is correct In the current analog inputs check that the polarity is the right one and the shunt is present If itis internal by means of the proper jumper and if itis external checking that the shunt resistance 3 74 ohm is conne
6. cted to the right terminals In the Pt 100 inputs checking the third wire will avoid saturated indications In the inputs for mV and termopar beside to the polarity is important to assure that the internal shunt of that channel is not selected Every voltage between terminals higher than 3 V from the same channel or between different channels may cause damages in the equipment lt is always recommended to use twisted wire cable with shield for the signal lines and to use different pipelines than the ones for power or control For a right shielding connect it to a good quality ground instrumentation ground in only one of the sides Do never connect to ground both sides of the shield Avoid as far as possible the electrical ground where the circuit breakers motors and power units are connected to Usually due to the deficient quality of these type of grounds they are a source of electrical disturbances It is recommended to use 1 mm cooper cable for the signals to be measured The connection of the communications must be exclusively done with twisted and shielded cable Internal jumper S1 in position 2 3 page 7 Internal jumper S1 en posicion 1 2 page 7 Measure TAG Status of the digital outputs Keyboard Error messages At any place returns to the T Check probe and connections preceeding menu Measure is over the high limit or 9999 Advance to the next step Data validation Measure is over then low lim
7. ins Female The housing must be opened in the case that the jumpers default setting wants to be changed By pressing the two nails at each side of the housing the cover can be removed EVERY TIME THAT THE HOUSING MUST BE OPENED BE SURE THAT THE EQUIPMENT BE WITHOUT VOLTAGE IN ALL THE TERMINALS Each analog input has a two positions jumper that allows to choose between the general input and the input of mA with internal shunt Once the jumper is set in the desired position use the configuration program to select the input type Jumper in 2 3 Pt 100 PTC mV V TP 0 4 20 mA without internal shunt Jumper in 1 2 0 4 20 mA with internal shunt Default position is 2 3 Number of inputs 1 input Types PTC TP RTD mV V mA Impedance gt 1 MQ mV amp internal shunt 3 75 Q 1 25 pom mA Range CJC 0 a 50 C internal sensor Standards for signals IEC584 00 and IEC751 Pt 100 i K R S T E N B 200 600 C 50 150 C gt VORAJ einen 75 mV amp 2 VDC UIE sla 0 4 20 mA LinealizatiOni 20 steps Precision at 25 C sie 0 1 Sampling time 125 ms 1 ch 250 ms 2 ch Termopar Logical inputs option Logical inputs 220 VAC DC 24 VACIDE in option Current consumption 2 mA max analog outputs option Quantity 1
8. it or 1999 Increases value Decreases value Starting Alarm 1 Alarm 2 Alarm 3 screen setting setting setting a a a Change value Change value Change value O w Desde cualquier pantalla del men regresa a la pantalla de inicio Pantalla inicial I I Hasta que cambie el men I onfiguracion Configuracion Salida ll Alarmas opcional gt 7 Defines type of input A TI E Indication a T Type physical Text editor i o units Noise Reading of lower line EL Termopar aj filt ti f mai 2 y ilter correction of main screen P iGO rtp Pt 100 ie a L en a I L i 7 0 E ILE 0600 jo b TypeB Type E i TypeR A TypeK I i i Ei E Tine e fiter fiter Change value i TypeN TypeT E 5 i i fa k j a Change value Y DA or og Peaks Average 4 i dvance letter i 70 Nolinealization fey Change value w Number of Minimum Maximum decimals a mo No decimal Change value i 1decimal 2 decimals 3 3 decimals PXX Indication of the linealization point being edited I I Repeatthisprocessforallthe required linealization points A Selectthelinealizationpoint AU Measure reading A Measure reading O from 1 to 20 When point 0 is O before to linealizate in O afterto linealizate in selected the linealization the edited point the edited point editor is exited Hysteresis Relay contact of the alarm M