1. once per 3 seconds Under voltage indication please change the batteries immediately User will get alert SMS about the low battery if the PIR detector is connected to the GSM alarm system 2 26 PCB Layout LED ON OFF Infrared sensor gal AS L vA 941 AST YY Tamper switch Zone setting Infrared sensor It detects the infrared rays released by human body motion please don t touch the surface and always keep it clean Tamper switch Once the case is opened in working state the tamper switch will be triggered and then generates an alarm signal Usage Open the case and remove the battery activation strip to activate batteries It will start self testing for one minute Mode Setting Test Button O Testing mode After self testing press the test button the sensor enters testing mode and detects once every 10 seconds After 3 minutes the LED flashes twice and the sensor enters the working mode Working mode In working state if the sensor is triggered more than twice within 3 minutes it will enter sleeping mode to save power After no movement within next 3 minutes the sensor goes back to the working mode Connect to alarm panel Press the connect key on the alarm panel and then press the test button of the sensor twice to send alarm signal When one beep is heard they are connected To check if they are connected successfully arm the system and trigger the sensor again if there is an a
2. the desired location mount the magnet no more than 1cm away from the transmitter and secure the transmitter and magnet with double sided tapes or screws Avoid mounting sensors in areas with a large quantity of metal or electrical wiring such as a furnace or utility room Specifications Power supply DC 1 5V AA 1 5V LR6 Battery x 1pc Static current lt 30uUA Alarm current lt 40mA Transmitting distance lt 80m in open area Radio frequency 315MHz 433MHz 75KHZz Housing material ABS plastic Operating temperature 10 C 55 C Relative humidity lt 80 non condensing Transmitter dimensions LxWxH 71x34 x17 5mm Mag net dimensions LxWxH 51x 12x 13 5mm 25 26 Wireless PIR Motion Detector Features PIR 900 is a high performance wireless PI R motion detector It consists of digital dual core fuzzy logic infrared control chip and intelligent analysis which effectively identify interference signals from body movement signals and reduce false alarm rate With automatic temperature compensation and anti air turbulence technology it easily adapts to environmental changes The detector also has the advantages of energy saving reliability and easy installation Appearance 1 Detection window 2 LED indicator 3 Bracket LED Indication Flash continuously Under the self testing state Flash once Intruder is detected Flash twice Self testing is finished enters the working mode Flash
3. G3 Security Alarm System L Printed in Hong Kong PA OI AL EN 1301 V4 0 Features ARM Auror CPU Embedded breathing lamp Support 50 wireless sensors and 10 remote controls Built in 1 000 000 RF codes combination maintains high reliability Cellular communicator simple operation Store 5 alarm phone numbers Exit amp entry delay SMS alert for low battery of two way accessories Arm amp disarm the system by SMS or free phone call Remote monitoring site via phone Built in 110dB siren deterring intruders on site Built in 4 pcs of AA 1 5V 1800mAh rechargeable battery enables 12 hour standby SMS alerts for power failure power recovery and low power 850 900 1800 1900MHz GSM frequency applicable for universal Control Panel Features 1 Power Arm Status Low Power LED Indicator 2 GSM Signal Connect Alarm LED Indicator 3 Panic Button 4 Breathing Lamp 5 Stand 6 Monitoring MIC The Back Side of the Control Panel 1 Sim Card Slot 2 Connect Button 3 Power On Oft 4 Adapter Interface 1 Power Arm Status LED Indication Low Power LED Indicator Disarm in green Arm in yellow Lower power flashes in green GSM Signal Connect Alarm LED Indicator GSM network searching Fast flashes in green GSM signal is normal Slow flashes in green Connect LED Lights in red Alarm LED Fast flashes in red Connect Accessories Press connect button the connect LED lights on then trigger
4. and start to monitor the site Forward gt Edit Change Information of Alarm Zone Forward gt Edit Notice Due to SMS character limit only 4 zones contents can be edited At most 30 English characters for each line Other alarm zones are fixed as Zone 5 alarm Zone 6 alarm and so on 10 Set Delay Time Forward gt Edit Notice Once the function is setup when you arm the system one beep will be heard every second to remind the user to leave The reminding rhythm will be speeded up in the last 15 seconds Once the intruder is detected the alarm will be delayed accordingly 11 Set Siren Volume and Ringing Time Forward gt Edit 12 SMS Alert for Low Battery of Accessories available for two way accessories such as DWC 102 and PIR 900 910 SMS will be sent for 1 4 zones with its zone name as Zone name low battery J SMS alert for 5 50 zones will be Zone number low battery SMS Alert for Tamper Alarm of Accessories available for two way accessories such as DWC 102 and PIR 900 910 SMS will be sent for 1 4 zones with its zone name as Zone name tamper alarm SMS alert for 5 50 zones will be Zone number tamper alarm me 13 14 Arm amp Disarm by Free Phone Call Arm Call the control panel number hang up when hearing the ring tone The panel will call back The user hangs up the phone directly to arm the system Di
5. he remote control is pressed the system immediately goes into emergent alarming state Home Mode Zone Setup D3 D3 Home Mode Zone Normal Zone The PIR motion detector is set in Home Mode Zone in default Users should reconnect the detector with the control panel after the zone is changed 24 H Zone D3 Note It is recommended to set smoke detector gas detector and outdoor beam sensor at 24 H zone 21 Wireless Door Window Contact Features The DWC 100 is a Door Window Contact that can be installed on doors windows and any other objects that open and close The sensor transmits signals to the control panel when a magnet mounted near the sensor is moved away External input for wired accessory is available at the N C interface The tamper protection ensures that sabotage attempts to move the contact will result in an alarm activation Appearance LED indicator Transmitter Magnet 22 LED Indication LED flashes once Door window is opened and transmitter sends signal to the contro panel LED flashes quickly Low power indication please change battery as soon as possible PCB Layout gt gt a U lt m 28 ony Tamper switch Zone setting 23 Installation amp Notice Open the case and remove the battery activation strip Mount the sensor on the door frame and the magnet on the door Make sure the magnet is on the right side of the transmitter Place the transmitter in
6. larming the connection is successful 29 30 Installation amp Notices Avoid mounting the detector close to windows air conditioner heater refrigerator oven sunshine and places where the temperature changes fast or the air stream flows frequently If two detectors are installed in the same detection scope please adjust the location to avoid interference and false alarm Top view Side view Fix the bracket on the wall with screws and attach the detector to the bracket Adjust installation height or bracket to change the detection distance and angle It is recommended to mount it at the height of 2m from the ground The detector is more sensitive to the cross movement than to the vertical movement so the performance of detector is best when the detection direction is vertical to the walking direction of people Testing Walk Test A After installation power on the detector After one minute self testing press the test button walk in the scope from left to right or from right to left and watch the LED indicator to make sure the detector is working B The LED indicator flashes once when body movement is detected C Adjust the detector angle accordingly to achieve the best detection effect Detection Scope Om 2m 4m 6m 8m 110 2m A A Om bam Top view Side view 31 32 Specifications Power supply DC 3V AA 1 5V LR6 Battery x 2 pcs Static current lt 50uA Alarm current lt 9 5mA Detectio
7. n scope 8m 110 Transmitting distance lt 80m in open area Radio frequency 315MHz 433MHz 75KHz Housing material ABS plastic Operation Condition Temperature 10 C 55 C Relative humidity lt 80 non condensing Detector dimensions L x W x H 108 x 52 x 36 8 mm Bracket dimensions L x W x H 52 x 30 x 26 5 mm
8. nsors Radio frequency 315MHz 433MHz 75KHz Housing material ABS plastic Operation condition Temperature 10 C 55 C Humidity lt 80 non condensing Size LxWxH Panel 12 6x3 6x13cm Stand 15x7x1lcm 17 18 Wireless Remote Control LED Indicator Disarm Panic Press Arm O to arm the alarm panel and the LED indicator lights on siren hoots once the system enters Arm state If there comes an intruder the siren will hoot to deter the intruder The siren turns off after ringing for 5 minutes as default setting At the same time the system dials the pre stored phone numbers automatically Press Disarm to disarm the alarm panel and the LED indicator blacks out siren hoots twice the system is disarmed When intruders are detected siren will keep hooting Press Disarm to stop siren hooting Home Mode Press Stay D button on the remote control the system state LED is on All the sensors in other zones are armed except the motion detector in zone A which is disarmed so that user can move freely at home 19 20 Mute Mode _ 9 90 Press Stay button on the remote control then press Arm or Disarm button the siren keeps silent to finish the operation The system is armed or disarmed in mute without disturbing other people Emergency Call sos 2 No matter what state the control panel is in once SOS button on A t
9. sarm Call the control panel number hold on until the panel hangs up the call The panel will not call back System is disarmed Emergency Call Press SOS button on the control panel or the remote control the system will alarm immediately and send SMS of Emergency Call Turn On Off the Breathing LED Send text 30 to SIM card number of control panel to turn off the breathing LED Notice No SMS reply from control panel Send text 31 to SIM card number of control panel to turn on the breathing LED Notice No SMS reply from control panel Clear Accessories Press down the connect button until 2 beeps are heard All the connected accessories will be cleared Language Setup The SMS language can be modified by sending SMS code to the SIM card of the alarm system English Restore Factory Setting Press connect button and SOS button on the control panel at the same time after three beeps all settings are restored to default 15 16 Specifications Product name GSM SMS Security Alarm System Model No CG 8800G3 Control panel s power supply Input AC 110 240V 50 60Hz Output DC 12V 500mA GSM working frequency 850 900 1800 1900MHz Standby current SOMA Alarm current 170mA Internal battery backup AA 1 5V 1800mAh rechargeable battery x 4 pcs Internal siren 110dB Allowed amount of expandable wireless accessories 10 PCS Wireless Remote Control and 50 PCS Wireless Se
10. the accessory once it will be connected after a beep Once two beeps are heard the accessory has been connected before The first connected accessory is in Zone 1 the second one in Zone 2 and so on Connect Wireless Siren The newly added wireless siren can be used after connecting to the control panel Operation Press the Connect Button of the wireless siren for 0 5 second the Connect Button LED indicator lights on and then press the SOS Button on the control panel the siren will be connected after one beep is heard Testing Press the Arm Button on the remote control to make sure that the internal siren and wireless siren both beep once the connection is successful If not the connection fails please reconnect them Once the intruder is detected both internal siren and wireless siren will hoot to deter the illegal intruder The siren will be off in 5 minutes as the default setting At the same time the alarm system will send SMS and auto dial to users SMS Operation Disarm Insert a sim card to the control panel To turn off the alarm system then send an SMS of to the sim card number the operation guide message will be replied You can control the alarm system by following the guide message b en Gss Arm To turn on the alarm system l we i Call back Monitor Store Phone Numbers Send 2 to the sim card number the alarm will call back Pick up the phone