SkyAir Product Brochure

image

Contents

1. Model Indoor unit FHQ71BWV1A FHQ100BWV1A FHQ125BWV1A FHQ140CAVEA FHQ100BWV1A FHQ125BWV1A FHQ140CAVEA iure Outdoor unit RZQS71AV1 RZQS100AV1 RZQS125AV1 RZQS140AV1 RZQS100AY1 RZQS125AY1 RZQS140AY1 Power supply 1 Phase 220 240 V 50 Hz 3 Phase 380 415 V 50 Hz Cooling capacity kW 5B 92 13152 182 9 2 11 2 13 2 Rated Min Max 3 2 8 0 5 0 11 2 5 7 14 0 6 2 15 5 5 0 11 2 5 7 14 0 6 2 15 5 Heating capacity2 3 kW wo 10 5 13 5 16 0 105 135 16 0 Rated Min Max 3 5 9 0 5 1 12 8 6 0 16 2 6 2 18 0 5 1 12 8 6 0 16 2 6 2 18 0 Power consumption Cooling kW 1 77 2 85 3 50 4 34 2 85 3 56 4 34 Heating kW 2 32 3 26 4 35 4 94 3 26 4 35 4 94 EER Cooling kW kW 3 28 323 315 3 04 323 3 18 3 04 COP Heating kW 3 23 322 So 3 24 3 22 eu 3 24 Maer Colour White Fresh white White Fresh white m Airflow rate H M L Is 283 233 400 333 500 417 567 483 400 400 333 500 417 567 483 400 m min 17 14 24 20 30 25 34 29 24 24 20 30 25 34 29 24 Sound pressure level H M L 4 dB A 39 35 42 37 44 39 46 42 38 42 37 44 39 46 42 38 Sound power level H M L 5 dB A 55 51 58 53 60 55 64 60 56 58 53 60 55 64 60 56 Dimensions HxW
2. m z Connection position 300 860 910 Ceiling opening space Note 4 81_ 2x100 200 _85 Connection position 81_ 2X100 200 85 of branch duct orlessl 710 Hanging bolt pitch 950 124 weet RS 160 round shape type Note 2 L S 16 M4 Hole z 16 M4 Hole Piping Connection o Et Side Kaz IE M S N SU E gt lt q WI as 4 S z 157 AS 157 Qo SIS 360 RT 350 MR 5 3 GE square shaped type GE square shaped type G ZE zr o S N Connection NIZ Ide M a 8 FCQ50 71KAVEA FCQ100 140KAVEA 160 420 A_ arrow view e um 167 Connection position m Connection position 93 67 al branch d 2 dt 109 of branch duct 95 SE ype T Tos square shaped type 29 i FCQ50 71KAVEA FCQ50 71KAVEA Prepared hole Pre ared hole lozko wat E H4 16 M4 Prepared hole l gt X Q RL 840 55 Connection position NG 27 M4 Prepared hole sr S ramo ERR i ype 28 840 55 Sh Sha T L S 1180 2X100 200 8 7 S m gl H mio wa nio OI L zm 2 50 SCH SL She JA DE st G U I STN a S AJO lt 3 al o o ZS oko LO EJ T0 o H l eo S eo E OSP RA gal N D Si Connection position a 2700 SNR SEI o 2700 um 35 or less GA a ji hie mnd Sape type g hagc olo 35 0r less siis und Snape ty
3. B Piping direction or Ee JE 5 S o SM i EL oO o E SEA bo S UY lisse b TUBA Z 120 or less 2500 or more 50 or more For installation Requred space in high spaces L r _104 894 52 80 hole ea m 73 Piping and Outside line Em intake 80 hole L UU We Sp ETL S 60 5j Approx345 98 Ua ma Approx 390 Mounting location W Air outlet Approx 475 Gas piping Notes 6 Liquid piping Location of unit s of Name Plate Right side surface of casing Drain hose In case of using wireless remote controller this position will be a signal receiver Refer to the drawing of wireless remote contorller in detail Q Earth terminal 3 Please do not place the thing been damp and troubled under an indoor unit when the case where humidity is 80 or more and the drain outlet are choked up and the air filter are dirty dew may fall WALL MOUNTED TYPE Right side pipe connection hole Q Left side pipe connection hole FAQ100CVEA 4 A Piping direction A o G pprox 440 Oo Ee 5 8 BIE 7 2 A M 7 A 7 5 2 L amp Dimensions for 7 full open E A front panel Z E go d JAM el WJ zm Wj IE REJ 3 Wig EE Z E a ae ee S 2500 or more 120 or A 50 or more Piping direction 1200 Name
4. Accessory required for indoor unit Wired Remote Controller d Note Remote controller cable not e 0 e included Cables must be procured locally y 140CA Foam O 6 9 B m Signal receiver unit Installed type Wireless remote controller and signal receiver unit are sold as a set Comfort Remote controller Cleanliness Control features Options Others D PES x c 9 5 gt Ie e Ke Te m Qo es O e o D o 8 c EE 9 E O Schale O O in O U SiE al g D D lee D o c Oo c O c E O ol 99 g O T 5 wo g m a lka l3 x On 2 sl Oe Ee SH ene gt NE E e Se BE X c C E S m K g S c jo zale O o gt IS S leu o 5 SS o D o 07 R U Na 5 IE Gl D gt O ES O o Z gt E E O23 co oO U D o E c o BG l oleic O D o ore 3 isp D Lef t 2 D Te E oj o Gs res es Gc g o H DH SW lasse gt ola Sea alg o g os 5 ols 5 o DO erae s Q c oy 2 7 PPPlSE Jas Ee e e e o8 O T 2 35 KE OL o IE OL bp TE o 9 D D T O OLSE t 5 DE M 0 Z O o El cao D lo DO 2 0 Se qu a ug gt S e 9 ES Ep 2 D D c Yo ll o 5 eN ol ae xs e SO NSZ ae eee ae SS sess z oa er ES eS lt A GS ii
5. RZQ100LV1 Night time quiet operation function The Automatic night quiet mode will initiate 8 hours after the peak temperature is reached in the daytime and normal operation will resume 10 hours after that Reducing noise will reduce capacity slightly Sound pressure level dB A Night Quiet Mode AZOSSOOOAVI 48 RZQS71AV1 TT RZQS100AV1 Y1 3 RZQS125AV1 Y1 RZQS140AV1 Y1 RZQ71LV1 RZQ100 125LV 1 RZQ140LV1 BJ Note Anechoic chamber conversion value measured according to JIS parameters and criteria During operation these values are somewhat higher owing to ambient conditions Value when cooling Value will differ when heating 15 Peak in outdoor temperature 2 S 100 o D O 50 x E 9 U 50 m mi She 2 lt uiet mode fe 46 8 5 On 8 00 12 00 16 00 20 00 0 00 4 00 8 00 Note In case of RZQS71AV1 RZQ100LV1 Inverter series RZQ125LV1 RZQ140LV1 Operation range Suited for year round cooling applications Cooling is efficient even in winter when indoor temperatures are higher than those outside such as in underground public spaces or offices with many computers E Wide operation range Outdoor temp CDB Outdoor temp CWB Durability As the bottom frame is subject to corrosion a corrosion proof galvarium steel plate is adopted to enhance the durability Heat exchange fins are provi
6. uonounj uonueA aJd yeg uonoe es ujened Bulms AN O LL Le O LC Vv LLI an gt LLI LLI I I lt O Q n ke E O O O Uniform 360 airflow cassette air conditioner Is setting Features GuiMs Ony Applicable when wired remote controller is used 2 For the outdoor units 3 Option Avoids uneven temperature and discomfort caused by drafts z Comfort enhanced by Round Flow 360 airflow Air movement is gentle e With uniform temperature with Rou nd Flow distribution e Enhanced Comfort 360 airflow can maintain comfort even if air Airflow m NN distribution AE discharge speed is creates uniform lower comfort throughout the space If you raise the set temperature by 1 to 1 5 C in cooling and lower in heating and velocity is decreased Greater comfort pat by 25 you still obtain KS the same feeling temperature and comfort a Adapts easily to the installation space e As air flows out from corner outlets comfort spreads more evenly Typical flow patterns There are a total of 23 flow patterns L shaped Opposite All round flow 3 way flow 2 way flow 2 way flow D er E g installed in E g installed E g installed in E g installed in middle of ceiling near a wall a corner a long room 4 way flow also possible Note Whatever the discharge direction the same type of panel is used If ins
7. 1 12 8 Power consumption Cooling kW 2 23 3 19 Heating kW 233 3 44 EER Cooling kW kW 3 18 3 13 COP Heating kW 3 43 3 26 indoor Colour Fresh white unti Airflow rate H M L Is 300 267 233 433 383 317 m min 18 16 14 26 23 19 Sound pressure level H M L 4 dB A 45 42 40 49 45 41 Sound power level H M L 5 dB A 61 58 56 65 62 58 Dimensions HxWxD mm 2901 050x238 3401 200240 Machine weight kg 13 117 Certified Cooling CWB 14 to 25 Operation range Heating CDB 15 to 27 EEN Colour Ivory white unit Compressor Type Hermetically sealed swing type Hermetically sealed scroll type Motor output kW 1 55 3 15 Refrigerant charge R 410A kg 2 9 Charged for 30 m 4 0 Charged for 30 m Sound pressure Cooling Heating dB A 50 52 53 55 level Night quiet mode dB A 46 49 Sound power level Cooling Heating dB A 69 Dimensions HxWxD mm 990x940x320 1 430x940x320 Machine weight kg 75 108 Certified Cooling CDB 5 to 46 Operation range Heating CWB 15 to 15 5 Piping Liquid Flare mm 09 5 connections Gas Flare mm 615 9 Drain Indoor unit mm VP13 D613x0 D918 Outdoor unit mm 026 0 Hole Max interunit piping length m 50 Equivalent length 70 m 75 Equivalent length 90 m Max installation level difference m 30 Heat insulation Both liquid and gas piping Note Rated cooling capacities are based on the following conditions Indoor temp 27 CDB 19 0 CWB outdoor temp 35 CDB 24 CWB Equiv refrigeration piping 7 5 m
8. EGI Brand name plate Note 2 DAir discharge grille Air suction grille Drain pipe connection VP20 Air filter For left piping 8 Gas pipe connection i Liquid pipe connection a a Drain pipe connection S x O DEarth terminal inside the control box M4 d ALA 8 Hanger 76 83 Rear piping penetration cover 3 2 105 4 Top panel penetration cover 156 Right side pipe connection Notes Location of unit s Name Plate Bottom of fan housing inside the suction grille n case of using wireless remote controller this position will be a signal receiver Refer to the drawing of wireless remote controller in detail Please do not place the thing been damp and troubled under an indoor unit When the case where humidity is 8096 or more and the drain outlet are choked up and the air filter are dirty dew may fall 27 2 Left back drain pipe connection Left side drain pipe connection 4 Right side drain pipe connection 5 Hole of wall for taking out in piping back Upward drain pipe connection Upward gas pipe connection 68 Upward liquid pipe connection WALL MOUNTED TYPE FAQ71CVEA T Approx 400 240 Dimensions for full open front panel OT NG Piping direction Name plate Note 2 Piping direction 50 or more 1050 Requred space fe
9. Flow gt Note Rated cooling capacities are based on the following conditions Indoor temp 27 CDB Equiv refrigeration piping 7 5 m horizontal Rated heating capacities are based on the FCQ50KAVEA FCQ60KAVEA FCQ71KAVEA FCQ100KAVEA FCQ125KAVEA FCQ140KAVEA following conditions Indoor temp 20 CDB outdoor temp 7 CDB 6 CWB Equiv RZQS50AV1 RZQS60AV1 RZQS71AV1 RZQS100AV1 Y1 RZQS125AV1 Y1 RZQS140AV1 Y1 refrigeration piping 7 5 m horizontal Wh t COP COP is equal to capacity kW divided by power consumption kW and the larger the COP value the higher at IS the energy efficiency enabling cooling and heating with less electricity and increasing the energy saving Coefficient of Performance performance High COP models 19 0 CWB outdoor temp 35 CDB 24 0 CWB CEILING MOUNTED CASSETTE TYPE 50 60 100 125 140 lt Round Flow gt Cooling 3 94 3 59 3 85 3 89 3 51 3 18 Heating 4 26 4 02 4 46 4 05 3 89 3 65 CEILING SUSPENDED TYPE O WALL MOUNTED TYPE Reduced installation work thanks to light compact outdoor unit Height 1 170 mm Weight 98 kg 15 kg RQ100LV1A Cooling 3 04 Heating 3 24 Cooling 3 18 3 13 3 43 3 26 Compactiand lightweight 4 CN 4 L x Ne X en A d Po 4 RZQ100LV1 Reduced by 180 mm Re
10. d DA IKIN PCSAU1439 SkyAir Air Conditioning System HEAT PUMP 50Hz PRODUCT RANGE Series 50 60 CEILING MOUNTED a A NEW a N lt RoundFlow gt Ze ZR nda on en FCQ5OKAVEA FCQ60KAVEA Outdoor unit RZQS60AV1 CEILING SUSPENDED TYPE Indoor unit WALL MOUNTED TYPE Indoor unit Outdoor unit OUTDOOR UNIT NEW CG Outdoor unit RZQS50AV1 RZQS60AV1 Inverter series Series 50 60 CEILING MOUNTED ARE amara L Indoor unit Outdoor unit OUTDOOR UNIT Outdoor unit 71 ZN FCQ71KAVEA RZQS71AV1 NEW FHQ71BWV1A RZQS71AV1 FAQ71CVEA RZQS71AV1 RZQS71AV1 71 ZA FCQ71KAVEA RZQ71LV1 a E RZQ71LV1 100 125 NEW N NEW i N NEW i N FCQ100KAVEA FCQ125KAVEA FCQ140KAVEA NEW NEW aam a FHQ100BWV1A FHQ125BWV1A FHQ140CAVEA RZQS100AV1 RZQS100AY1 RZQS125AV1 RZQS140AY1 FAQ100CVEA NEW t NEW T P RZQS100AV1 RZQS100AY1 RZQS125AV1 RZQS125AY1 RZQS140AV1 RZQS140AY1 100 125 140 FCQ100KAVEA FCQ125KAVEA FCQ140KAVEA RZQ100LV1 RZQ125LV1 RZQ140LV1 RZQ100LV1 RZQ125LV1 4 gt ei aS lt D E SS E R a s RZQ140LV1 N SkyAir Page 7 Page 11 Page 13 _ Page 15 Page 7 Page 15 Energy Efficient Achieved higher COP Complies with MEPS COP P NI CEILING MOUNTED CASSETTE TYPE lt Round
11. floor in air conditioning zones with high ceilings IM Two selectable temperature sensors Temperature sensors are included in the indoor unit and optional wired remote controller Temperature sensing closer to the target area is possible to further increase the comfort level Use the temperature sensor in the indoor unit when controlling air conditioning from another room Note Wireless remote controllers have no temperature sensor RR TEG d H Hot start after defrost Cold air flow is avoided when heating operation starts or when switching to heat after defrosting IM Year round cooling applicable Efficient cooling even in winter when the indoor temperatures are higher than those outside such as in underground public spaces or offices with many computers JM Night quiet operation The Automatic night quiet mode will initiate 8 hours after the peak temperature is reached in the daytime and normal operation will resume 10 hours after that B Weekly schedule timer Up to five operation ON OFF settings can be programmed per day for each day of the week Not only can the time be set for the operation ON setting but also the temperature IM Off timer programmed Sets and saves setting for an increment of time that automatically turns off air conditioner after a preset period of time for each time operation starts M Silver ion anti bacterial drain pan Mould proof drain pan includes a silver ion
12. l s w l lt ED OON DON o E Om w lag Wi 2 3 e 4 3 3 3 3 5 4 4 e e e e 5 6 7 A 4 1FHQ71 125BW 2 step FHQ140CA 3 step 2 nstallable on max 3 5 m 71 125BW 4 3 m 140CA high ceiling SApplicable when wired remote controller is used For the outdoor units sOption 6FHQ71 125BW option required FHQ140CA standard 7FHQ140CA only 11 New 140 model provides greater capacity for large spaces e The technology of the DC fan motor wide sirocco fan and large heat exchanger combine for greater airflow and quiet operation High Middle Low 46 42 38 dB A e Sophisticated design Flap neatly closes when not in use Fresh white colour e Installable on ceilings 4 3 m high e 3 fan speeds High Middle Low e Connection to a centralised control system is available no need for option card e Drain pump kit option includes a silver ion antibacterial agent that assists in preventing the growth of slime bacteria and mould that cause smells and clogging a Comfortable e Auto swing up and down and louvers left and right by hand bring comfort to the room fee eem p e Louver manually adjusts for straight or wide angle airflow e Installable on ceilings 3 5 m high FHa71 125BW e wo selectable temperature sensors Both indoor unit
13. plate Note 2 Piping direction so or more EE m Requred space Requred space in high spaces 35 5 MIDI LO lt 79 5 1085 RE meere as poi 80 hole Outside line N Piping and 80 hole Wiring intake LO aem Se 65 Approx 400 ER TT E ront gri TET SIN MENOR Air outlet ounting location Approx 465 Gas piping Notes 6 Liquid piping Location of unit s of Name Plate Right side surface of casing 6 Drain hose In case of using wireless remote controller this position will be a signal receiver Refer to the drawing of wireless remote contorller in detail C Earth terminal 3 Please do not place the thing been damp and troubled under an indoor unit when the case where humidity is 80 or more and the drain outlet are choked up and the air filter are dirty dew may fall 8 Right side pipe connection hole 9 Left side pipe connection hole 28 DIMENSIONS unit mm OUTDOOR UNIT A RZQS50 60AV1 RZQ71LV1 Hole for anchor bolt 4 M12 3 p 900 4 5 me 6 lt 5 gt R R LO CAT LO al co E s 8 X SPD LO co CO Oo 145 Gas pipe connection 2 Liquid pipe connection 8 Service port 4 Earth terminal M5 in switch box 5 Refrigerant piping intake 6 Power supply wiring intake 7 Transmission wiring int
14. 100BWV1A 1360 1400 Drain pipe connection VP20 For left piping 300 Notes Location of unit s Name Plate Bottom of fan housing inside the suction grille n case of using wireless remote controller this position will be a signal receiver Refer to the drawing of wireless remote controller in detail 3 Applies to FHQ71BV only The remote control code is the standard lt about 3 m outside the machine gt attached 0 5 mm x 2 wicks x O D 5 4 It is not attached to heat reclaim ventilator CEILING SUSPENDED TYPE FHQ125BWV1A 1550 1590 ees 20 NES ae o U Q 0 E Hanging bolt 3 680 4 M8 M10 J D U 10 E M i Z SS 8 8 ub Z Sl od GW SS SS ze S E 30 or more B 300r more SE S amp Service space Service space S9 5 LA Se SIE A Obstacle The Front Brand name plate 5 j Note 2 Ps Floor side Position slit hole for taking out in piping back View from the front Position Hole of wall for taking out in piping back View from the front 155 Air discharge grille Air suction grille Air filter Gas pipe connection Liquid pipe connection Drain pipe c
15. 30 m Charged for 30 m Charged for 30 m Charged for 30 m Sound pressure Cooling Heating dB A 49 51 51 53 54 56 level Night quiet mode dB A 45 47 50 Sound power level5 dB A 66 69 Dimensions HxWxD mm 770x900x320 990x940x320 1 170x900x320 1 430x940x320 Machine weight kg 64 75 98 108 Certified Outdoor Cooling CDB 5 to 46 Operation Range Heating CWB 15 to 15 5 Piping Liquid Flare mm 99 5 connections Gas Flare mm 015 9 Drain Indoor unit mm VP25 l DQ25x0 Dg32 Outdoor unit mm 026 0 Hole Max interunit piping length m 50 Equivalent length 70 75 Equivalent length 90 Max installation level difierence m 30 Heat insulation Both liquid and gas piping Note Rated cooling capacities are based on the following conditions Indoor temp 27 CDB 19 0 CWB outdoor temp 35 CDB 24 CWB Equiv refrigeration piping 7 5 m horizontal Rated heating capacities are based on the following conditions Indoor temp 20 CDB 15 CWB outdoor temp 7 CDB 6 CWB Equiv refrigeration piping 7 5 m horizontal Capacities are net including a deduction for cooling for indoor fan motor heat Anechoic chamber conversion value measured according to JIS parameters and criteria During operation these values are somewhat higher owing to ambient conditions SNumerical values are according to ISO 3741 1999 22 23 SPECIFICATIONS i CEILING SUSPENDED TYPE SS TEETH E EN
16. 38 EER Cooling kW kW 3 94 3 59 3 85 3 89 3 51 3 18 3 89 3 51 3 18 COP Heating kW 4 26 4 02 4 46 4 05 3 89 3 65 4 05 3 89 3 65 Indoor Colour Unit unit Decoration panel Fresh white Airflow rate H M L Is 350 292 225 533 433 333 550 467 375 533 433 333 550 467 375 m min 21 17 5 193 5 32 26 20 39 28 22 5 32 26 20 33 28 22 5 Sound pressure level H M L 4 dB A 35 31 5 28 43 37 5 32 44 39 34 44 40 36 43 37 5 32 44 39 34 44 40 36 Sound power level H L 5 dB A 53 46 60 50 61 52 61 54 60 50 61 52 61 54 Dimensions Unit mm 256x840x840 298x840x840 HxWxD Decoration panel mm 50x950x950 Machine Unit kg 21 24 weight Decoration panel kg 5 5 Certified Cooling CWB 14 to 25 Operation range Heating CDB 15 to 27 Outdoor Colour Ivory white unit Compressor Type Hermetically sealed swing type Hermetically sealed scroll type Motor output kW 1 2 1 6 1 55 3 15 Refrigerant charge R 410A kg 2 0 29 4 0 4 2 4 0 4 2 Charged for 30 m Charged for 30 m Charged for 30 m Charged for 30 m Charged for 30 m Charged for 30 m Sound pressure Cooling Heating dB A 48 50 50 52 53 55 54 56 53 55 54 56 level Night quiet mode dB A 44 46 49 50 49 50 Sound power levels dB A 66 69 69 Dimensions HxWxD mm 770x900x320 990x940x320 1 430x940x320 Machine weight kg 64 75 108 Certified Cooling CDB 5 to 46 Operation range Heating CWB 15 to 15 5 Piping Liquid Flare mm 69 5 connections Gas Flare mm 615 9 Drain Indoor unit mm VP25 I D 25xO D 32 Ou
17. D on the unit illuminates M External command control Operation and surveillance is carried out using the contact signal from the operation control box in the building surveillance security room An option is required M Central remote control An optional central remote controller enables centralised control of up to 1024 indoor units 64 groups from up to 1 kilometer away Bl Interlock control Enables interlocking control with external equipment such as Heat Reclaim Ventilator M DIII NET communication standard Standardly equipped interface enables connection to centralised control system without need of an adaptor flf Fresh air intake kit Applicable for ceiling mounted cassette type You can provide air conditioning with fresh air from outside Convenient for places where a ventilation fan cannot be installed Note Connecting ducts insect nets fire dampers air filters and other parts should as required be procured locally Outside Air fan interlocked with air conditioning unit is necessary Optional PCB KRP1C63 is required for interlocking t is recommended that the volume of outdoor air introduced through the kit is limited to 10 of the maximum airflow rate of the indoor unit Introducing higher quantities will increase the operating noise and may also influence temperature sending To achieve increased durability by improved resistance to salt corrosion and atmospheric pollution coated Anti cor
18. IKIN INDUSTRIES LTD Head Office Umeda Center Bldg 2 4 12 Nakazaki Nishi Kita ku Osaka 530 8323 Japan Tokyo Office JR Shinagawa East Bldg 2 18 1 Konan Minato ku Tokyo 108 0075 Japan http www daikin com global_ac CAII rights reserved 09 12 DN e Specifications designs and other content appearing in this brochure are current as of May 2015 but subject to change without notice CAII rights reserved 05 15 SS
19. LCD wireless remote controller ON OFF The wireless remote controller is supplied in a set with a signal receiver Signal receiver unit is contained inside decoration panel or indoor unit DOWN uP Shape of signal receiver unit differs according to the indoor unit Cran Note The signal receiver unit shown in the photograph is for mounting inside the decoration panel of the ceiling mounted cassette type ai mm Wireless remote controller for each indoor unit type A Signal receiver unit For ceiling mounted cassette type BRC7F634F Wireless remote controller SkyAir shares common control with the Heat Reclaim Ventilator and other Daikin air conditioning units thus simplifying interlocking operations SkyAir Indoor unit KE 4 d amp 4m de j Heat Reclaim LCD remote controller e ee a Ventilator for SkyAir indoor unit 18 Simple system provides a diverse assortment of control modes Control pattern Wired remote controller Wireless remote controller Control by 1 Basic system remote controller l Non polar double core gt Signal receiver unit installed max wiring length 500 m on indoor unit For control from 2 Control by 2 locations such as in room and control room remote controllers exits etc Connects 2 wired remote Not possible controllers See note 1 See note 2 3 8 O For simultan
20. QS60AV1 RZQS125AV1 Y1 RZQS140AV1 Y1 Easy installation and maintenance Pre charged for up to 30 metres If the refrigerant piping length does not exceed 30 m there is no need for on site gas charging 75 m piping length Applicable to RZQS100 140A and RZQ100 140L outdoor units M Allowed refrigerant piping length and level difference RZQS50 71A RZQS100 140A HZOZTE RZQ100 140L Pre charged Max 50 m 75 m length Equivalent Equivalent length 70m length 90m Max level 30 m difference Note Additional refrigerant charging is required if the refrigerant pipe is longer than the length 4 direction piping offers greater layout freedom The outer panel for the piping connection part of the front right side and backside can be removed and is easier for post installation piping work 1 Separation K V available Facilitates pump down Refrigerant recovery function A pump down switch is provided to make it easier to collect refrigerant if the unit is to be moved or layout modified Pump down function is available for pre charged refrigerant amount Low gas pressure detection function Effective gas monitoring reduces the labor required for operation maintenance and repairs Compact and light weight Heduced installation work thanks to light compact outdoor unit 990 mm 75 kg Height 1 170 mm Weight 98 kg RQ100LV1A Reduced by 180 mm Reduced by 23 kg
21. S piping side Receiver detail T S Ay Liquid crystal JI Eeer remote controller 5 wireless Al Remote controller ol holder Drain piping Y side gt L A A NE Z Decoration panel Esser CEILING SUSPENDED TYPE WALL MOUNTED TYPE Receiver installation procedure e Receiver installation procedure FHQ71 125BWV1A FHQ140CAVEA Receiver The Front Receiver The Front Receiver A ij N N on Receiver detail me oam O T o e 0 Receiver Receiver detail gt DAIKIN detail E 9 e E c B E Eh Wired type Remote controller dimensions BRC1E62 T T Installation method er case ower case Exposed cord T Embedded cord Embedded cord Condit 7 Top left EE use switch box 19 outlet outlet g N Operation S D A lamp Green 9 i a L A AI Code outlet hole eO EN 5x15 oblong hole 3 46 5X7 oblong hole 23 48 5 MAGNA 68 010 Switch box for one switch Switch box for two switch n 146 19 Lower case portion ex KJB111A ex KJB211A controller and optional accessory optional accessory control box A witch DOK Lower case portion field supplied part Note 1 Remote controller cord and staple are not attached They are field supplied parts Specifications of cord 2 If the hole size is too large or the location is not proper the hole may come out from the remote controller Type Vinyl cord with sheath or cable insulated thickness 1mm or more S
22. ST301BA61 3 intelligent Touch Controller DCS601C51 2 DCS601C51 3 Adaptor for wiring KRP1BA54 Wiring adaptor for electrical appendices KRP4AA52 Interface adaptor for SkyAir series DTA112BA51 Installation box for adaptor PCB KRP1CA93 KRP1D93A Remote sensor for indoor temperature KRCS01 1B KRCS01 4B Electrical box with earth terminal 3 blocks KJB311AA Electrical box with earth terminal 2 blocks KJB212AA Note Wiring for wired remote controller to be procured locally This optional accessory requires DTA112BA51 The indoor unit is equipped standardly with the interface adaptor for SkyAir series An option is unnecessary Installation box for adaptor PCB is necessary S WALL MOUNTED TYPE E Kit name EEN Remark FAQ71CVEA FAQ100CVEA Drain up kit K KDU572EVE Remote controller Wireless type Heat pump BRC7EB518 Navigation Remote Controller Wired type Nav Ease BRC1E62 Remote sensor for Indoor temperature KRCS01 4B Central remote controller DCS302CA61 Unified ON OFF controller DCS301BA61 Schedule timer DST301BA61 intelligent Touch Controller DCS601C51 Wiring adaptor for electrical appendices KRP4AA51 Installation box for adaptor PCB KRP4AA93 Electrical box with earth terminal 3 blocks KJB311AA Electrical box with earth terminal 2 blocks KJB212AA Noise filter For electromagnetic interface use only KEK26 1A Note Wiring for wired remote controller to be procured locally The indoor unit is equipped standardly with the inter
23. X x Teil Sen Ios 1 way branch unit 2 way flow X O O 04 K K In some cases depending on how the unit is embedded in the ceiling use of branch ducts and fresh air intake kits may not be possible Before starting installation work make sure to check whether or not joint installation is possible In particular ensure that the lower fixing position caused by the addition of panel spacers is acceptable Use a chamber connection kit if two different types of optional chamber are used together In this case the fresh air intake kit must be installed in the upper position It is not possible to use panel spacers in a 2 way flow installation It is not possible to install a branch duct on the same side to which a fresh air intake kit direct mount is installed 24 OPTIONS Indoor unit i CEILING SUSPENDED TYPE Name of option Remark inane FHQ71BWV1A FHQ100BWV1A FHQ125BWV1A FHQ140CAVEA Fresh air intake kit KDDQ50A140 Drain pump kit KDU50N125VE KDU50P140VE L type piping kit for upward direction KHFP5MA160 KHFP5N160 Remote controller Wireless type Heat pump BRC7EA63W BRC7GA53 Navigation Remote Controller Wired type Nav Ease BRC1E62 Central remote controller DCS302CA61 2 DCS302CA61 3 Unified ON OFF controller DCS301BA61 2 DCS301BA61 2 Schedule timer DST301BA61 2 D
24. ake Drain pipe connection OUTDOOR UNIT RZQS71AV1 RZQ100LV1 Hole for anchor bolt 4 M12 345 940 3 4 2 990 5 LO O 8 8 89 7 6 8 5 142 1 16 o Gas pipe connection 5 B Liquid pipe connection ry Service port a 4 Grounding terminal in switch box M5 35 Refrigerant piping intake 9 25 Power supply wiring intake 203 _ _153_ _179 7 Control wiring intake Drain pipe connection 29 OUTDOOR UNIT RZQ125LV1 Hole for anchor bolt 4 M12 345 355 1170 Se os a 2777 KC See NSE A SE NJ NS ek eg Hole for anchor bolt 4 M12 350 8457 355 30 OOOO OO T 223 7 C 6 5 LO o e LO 52 13 67 el CD Gas pipe connection Liquid pipe connection 8 Service port Grounding terminal Refrigerant piping intake Power supply wiring intake Control wiring intake Drain outlet Gas pipe connection Liq
25. and wired remote controller option BRc1E62 contain temperature sensors Temperature sensing can be set at the unit or to further improve comfort level closer to the target area at the wired remote control This feature requires initial setting by the installer Temperature sensor on indoor unit must be used when the air conditioner is controlled from another room Wireless remote controller does not have a temperature sensor e Switchable fan speed High Low FHQ71 125BW e Programme Dry Dehumidification is a microprocessor controlled to prevent abrupt and uncomfortable changes in air temperature Quiet operation A Indoor unit Middle Low 71BW 35 Note Anechoic chamber 100BW SA 125BW T 140CA INE an Uses quiet stream fan and other quiet technologies FHQ71 125BW Turbulent flow is reduced Straightening plate Quiet stream fan Installation flexibility for freedom of design 30 mm 30 m or more or more Water used in the test run can now be drained from the air discharge opening rather than from the side as was formerly the case The unit fits more snugly into tight spaces e Drain pump kit option can be easily incorporated Drain pipe connection can be done inside the unit refrigerant and drain pipe outlets are at the same opening 600 mm Drain pump kit built inside main unit e All wiring and internal servicing can be don
26. antibacterial agent that assists in preventing the growth of slime bacteria and mould that cause smells and clogging 20 21 Work and Servicing M Drain pump mechanism Applicable for ceiling mounted cassette type and ceiling suspended type Steeper gradient realises more efficient condensate drainage High lift is especially useful for long lengths of drain piping M Pre charged for up to 30 metres If the refrigerant piping length does not exceed 30 m there is no need for on site gas charging M Filter sign The filter sign warns you when it is time to clean the filter When using a wired remote controller the sign is displayed in the LCD When using a wireless remote controller the filter sign lamp illuminates on the signal receiver unit M Ceiling soiling prevention function Applicable for ceiling mounted cassette type Daikin s innovative air discharge mechanism keeps airflow away from the ceiling Ceiling cleaning is less frequently required Gontrol features M Auto restart If there is a power outage while the equipment is operating operations will restart in the same mode as before the power cut when electricity is restored Bf Auto cooling heating change over Heat pump oniy Detects difference in preset temperature and actual room temperature and automatically switches to cooling or heating accordingly ff Control by 2 remote controllers Using 2 remote controllers you can opera
27. c chamber conversion all models 100KA 43 37 5 32 value measured according to JIS 125KA 44 39 34 parameters and criteria During ion th h 140KA 44 40 TK eer 3 Optimal comfort and convenience Quick and easy to install assured by 2 air discharge modes e Just 256 mm high Installable in tight ceiling Spaces 50 71KA Setting to prevent soiling Air direction Standard setting eg i g of ceiling field setting l si 266 mm Desired Standard setting to Recommended for shops with 256 mm light coloured ceilings that 1 298 mm high with 100 140KA Auto swing U Auto swing between a Auto swing between en 15 and 60 dy 25 and 60 s e SE Easy height adjustment AE 7 Settable to 5 different A Settable to 5 different Each corner of the SLs levels between 15 and 60 levels between 25 and 60 unit has an Adjuster Pocket that lets you Draft f At heating startup and thermo OFF air discharge il di h ra peel EI P is automatically set to a near horizontal 25 or 30 Sai y aajust the In heating mode to prevent direct exposure to cool air drafts unit s suspended height Auto air The air direction is set automatically to the Note direction control J memorised position of the previous air direction If the wireless remote control option is installed a light Note receptor unit is housed in one of the adjuster pockets Air direction is set to the s
28. ded with anti corrosion treatment Construction Non treated fin 7777777 Aluminium Anti corrosion Hydrophilic film Corrosion resistant treated heat exchangers acrylic resin Demand Control Function The maximum capacity is maintained within a set level of power consumption which makes it possible to keep a comfortable and effective demand control Limitation Power consumption 8 00 12 00 16 00 Required for KRP58M51 Option 20 00 Time Technology for energy efficiency The high efficiency compressor to achieve a high COP Compressor equiped with Reluctance DC motor Daikin DC Inverter models are equipped with the Reluctance DC motor for compressor The Reluctance DC motor uses 2 different types of torque neodymium magnet and reluctance torque This motor can save energy because it generates more power with a smaller electric power than an AC or conventional DC motor Reluctance DC Motor eo CO eo Conventional DC motor Motor efficiency 96 A e o eo 0 30 60 90 120 Note Data are based on studies conducted under controlled conditions at a Daikin laboratory 1 A neodymium magnet is approximately 10 times stronger than a standard ferrite magnet 2 The torque created by the change in power between the iron and magnet parts RZQS50 71A RZQ71 100L gt gt Swing compressor Energy savings is realised eliminating the friction and th
29. duced by 23 kg _NavEasez Wired Remote Controller Clear Display Simple operation e Large buttons and arrow keys e Guide on display e Dot matrix display e Backlight display Inverter series Energy saving f an NS e Setpoint range set e Setpoint auto reset e Off timer programmed Comfortable Enhanced comfort with Inverter Inverter performs variable control of frequency which determines air conditioner s power performance e Weekly schedule e Multilingual display al e NL od Wired Remote Controller BRC1E62 Inverter series Soft starter is unnecessary making electrical installation work much simpler At startup full power is used to achieve the set temperature quickly Then the capacity is adjusted according to the outdoor temperature changes and subtle indoor load changes to achieve fine capacity control Non inverter Current Starting current resulting in a more stable room temperature Non inverter type air Cooling operation conditioners must be Temp switched on and off t repeatedly causing large fluctuations of the room temperature mem Inverter power control pn Non inverter type air conditioner Quietroperation Night quiet operation function The Automatic night quiet mode Running current Inverter Time Current Time At startup inverter raises frequency smoothly eliminating the starting current spike Inver
30. e from under the unit e Pipes more easily rigged e Low gas pressure detection Easy maintenance e Non flocking flap Condensation does not easily form on and dirt does not cling to non flocking flap It is easy to clean Non flocking flap e Easy clean flat surfaces 9 Oil resistant grille e Cil resistant plastic is used for the air suction grille This satisfies durability in restaurants and other similar environments Note Intended for use in salons dining rooms and ordinary sales floors this specification is not suitable for kitchens or other harsh environments sJeBueuoxe Iesy D91e9J UOISOJIOO UY 2 plepue s uONeoIUNWWOS 3N IIIQ O0 UO9 YDO JalU E o TE onuoo eyouJeJ eue G 3 O Eo Ouo9 onal rd BET EN puewwoo euJ9 X3 A Bo p 58 O o Cos Esc J9 OJUOO c EMR ESOS O E52 9jouJ81 Aq joNUOI dro 5 k ad W 609 O EN c in 5 SE 55 SJo oJ uoo Dos 3 6 9 0 E z 9 x ES 910UJ8I z Ag JONUOD D A Bec 5 O x Z JO o oBueuo c 2 8 o ss buneeu Burooo oiny e lT E So o E Ce E ueIseJ olny O o ib a n 8 C3 2 i C uonounj sisouBeIp HoS z o e l RES uoi ejedo KoueBJeui3 J O 9 N gt l M o uonoejep N CH 6 go VS 4 Oo eJjnsseJd seb MOT o WI a 7 o lt E a UBIS JON LL O o tu OE oi dn a st 10 peBJeuo ad wsiueysaw duund ugi JOVI Are joo4d p noJA 3
31. e leakage of refrigerant gas Swing bushing Refrigerant gas y Piston by incorporated blade and roller Smooth Air Inlet Bell Mouth and Aero Spiral Fan These two features work to reduce noise Guides are added to the bell mouth intake to reduce turbulence in the airflow generated by fan suction The Aero Spiral Fan features fan blades with the bent blade edges further reducing turbulence DC fan motor Efficiency improved in all areas compared to AC motors especially at low speeds Reluctance DC motor gt gt Smooth sine wave DC inverter Use of an optimised sine wave smoothes motor rotation further improving operating efficiency RZQS100 140A RZQ125 140L gt gt The structural scroll Sucked gas is compressed in the scrolling part before the heated motor so that the machine compress the non expanded gas resulting in high efficiency compression Sine wave DC inverter af Discharge Without the bent blade edge With the bent blade edge Escaping eddies are sucked in by the bent blade edges reducing overall turbulence 16 WT LCD REMOTE CONTROLLEI Easy to read LCD remote controller allows various system Remote controller options are shown on the page introducing each indoor unit model This simple contemporary remote controller with fresh white colour matches your interior design The clear backlight display with large
32. easy to read text makes navigation easy and provides one touch control over your in home in 6 comfort S Q7 amp NT BRC1E62 Clear Display Dot matrix display A combination of fine dots enables various icons Large text display is easy to see Backlight display Auto PO Energy saving Auto operation mode CEJ Setpoint auto reset Until now only the temperature for one point could be Even if the set temperature is changed it returns to e Ate Rest set but now the new remote controller BRC1E62 the preset temperature after a preset period of time n ed allows the setting of both Cooling and Heating and with Period selectable from Set tem 20 the fan operation mid range temperatures are 30min 60min 90min 1 20min D comfortable andoperation is more energy efficient Restaurant sample EEEN O Sn 27 C CED 2 setpoints e Cooling Heating Temperature is set to 27 C Full tables at lunchtime Then is lowered to 24 C 26 C ENAR Heatin TET Coolin dee Fan operation teu 27 C CEJ Setpoint range set Automatically returns to automatically Saves energy by limiting the min and max set RA RUE Setting possible for after 30 60 90 temperature and 120 minutes Avoids excessive heating or Setpoint range set cooling em vc Off timer programmed This function is convenient when Sets and saves set
33. ement of SkyAir 1 024 indoor units is possible to be executed twice a day for a week at a time System In a variety of ways Interface adaptor for SkyAir series Enables centralised control via connection to a high speed The interface adaptor for the SkyAir series is DIII NET communication system adopted for the Daikin optional except for the ceiling mounted cassette type DTA112BA51 Option VRV system lt Round Flow gt ceiling suspended type 140CA Necessary for interface adaptor for SkyAir series with the central remote only and wall mounted type control units shown at above 19 Abundance of features that provide comfortable air conditioning in stores and offices Note Some features only available on selected models See model pages for full list of features applicable to each unit Comfort lf Auto swing Delivers comfortable air conditioning to all areas near to and far from the air conditioner M The air flow direction can be fixed at your desited angle by the remote controller M Swing pattern selection standard ceiling soiling prevention You can freely set 2 air discharge settings by remote controller 1 Air direction in standard 2 Air direction in ceiling soiling setting prevention NU d M Draft prevention function heating To prevent cold air drafts automatically adjusts airflow to near horizontal position when heating initially starts or when the thermostat turns off JM Switc
34. eous Group control control of up to 16 ZEE P gt SSS e indoor units eAutomatic address setting function e Automatic address setting function 8 e Signal receiver unit installed on 1 indoor unit Operation and E H surveillance is carried out Control by using the contact signal mn Z I B from the operation control external command box in the building surveillance security Optional wiring adaptor for e Optional wiring adaptor for room electrical aopendices is necessary electrical aopendices is necessary Central remote controller option l TU Central remote controller option 3 BI 316 B Centralised control of Sj RN Centralised remote up to 64 indoor groups I CG Control from remote location up to 1 kilometer away E Optional SkyAir series interface Optional SkyAir series interface adaptor required See note 4 adaptor required See note 4 8 8 Heat Reclaim Heat Reclaim Ventilator Ventilator Link by remote z USCH Kel controller group control Can be operated simultaneously Can be operated simultaneously or independently by remote controller li N by remote controller set by ventilation mode P set by ventilation mode Interlock control with Hea
35. etting Air discharge setting is selected from the remote controller by field setting e Two selectable temperature sensors e Switchable fan speed High Middle Low e Auto airflow rate When BRC1E62 is used e Programme Dry Dehumidification is microprocessor controlled to prevent abrupt and uncomfortable changes in air temperature a Easy installing and servicing e 6 direction piping offers chive greater installation AP 7 5 R k left pip aCK le ipe Bottom left pipe Right pipe Back right pipe Bottom right pipe e Maintenance possible from the front of the unit All maintenance tasks can be carried out via front access During service work attachment and detachment of parts is easier e Drain pump kit is available as option Installs onto side of unit Height of drain up L Refrigerant piping 1 000 mm I V VN Indoor unit Drain pump kit Drain pump kit can be installed on either left and right side of the air conditioner e Connection to a centralised control system is available no need for option card z Easy cleaning e Removable and washable grille i 5 e Flat panel easy to wipe dust off e Non flocking flaps Condensation does not easily form on and dirt does not cling to non flocking flaps It is easy to clean OUTDOOR UNIT BNN AN Kaa NN al RZQS50AV1 RZQS71AV1 RZQS100AV1 Y1 RZQ71LV1 RZ
36. face adaptor for SkyAir series An option is unnecessary 3Installation box for adaptor PCB KRP4AA93 is necessary Outdoor unit Kit name Heat pump ELLE jp RZQS100AV1 RZQS125AV1 RZQS140AV1 RZQS100AY1 RZQS125AY1 RZQS140AY1 RZQS50AV1 RZQS60AV1 RZQS71AV1 Central drain plug KKPJ5F180 KKPJ5G280 Wire fixture for preventing overturning K KYZP15C Fixture for preventing overturning KPT 60B160 KKTP5B112 Demand adaptor KRP58M51 Name of option Katan ame RZQ71LV1 RZQ100LV1 RZQ125LV1 RZQ140LV1 Central drain plug KKPJ5F180 KKPJ5G280 KKPJ5F180 KKPJ5G280 Wire fixture for preventing overturning K KYZP15C Fixture for preventing overturning KPT 60B160 KKTP5B112 KPT 60B160 KKTP5B112 Demand adaptor KRP58M51 CEILING MOUNTED CASSETTE TYPE FCQ50 140KAVEA DIMENSIONS uni mm FCQ50 140KAVEA FCQ50 71KAVEA FCQ100 140KAVEA
37. hable fan speed High setting provides maximum reach while low setting minimises drafts lf Auto airflow rate Airflow rate is automatically controlled in accordance with the difference between room temperature and set temperature IM High fan speed mode Applicable for wall mounted type You can increase fan speed approximately 10 higher than the high setting M Programme Dry Dehumidification is a microprocessor controlled to prevent abrupt and uncomfortable changes in air temperature Useful for reducing uncomfortable humidity without uncomfortable cooling of the room Remote Controller fl Setpoint auto reset Even if the set temperature is changed it returns to the preset temperature after a preset period of time Bf Setpoint range set Saves energy by limiting the minimum and maximum set temperatures Avoids excessive heating and cooling Cleanliness JM Anti bacterial air filter The Air filter has a anti bacterial treatment to help prevent the growth of bacteria and mould on it HM Mould proof air filter Sanitary filter has mould resistant treatment M High ceiling application Applicable for ceiling mounted cassette type and ceiling suspended type A Note When units are installed on high ceilings depending on the model various restrictions concerning maximum height air discharge direction and choice of options may apply Delivers air conditioning comfort all the way down to the
38. horizontal Rated heating capacities are based on the following conditions Indoor temp 20 CDB 15 CWB outdoor temp 7 CDB 6 CWB Equiv refrigeration piping 7 5 m horizontal Capacities are net including a deduction for cooling for indoor fan motor heat Anechoic chamber conversion value measured according to JIS parameters and criteria During operation these values are somewhat higher owing to ambient conditions SNumerical values are according to ISO 3741 1999 OPTIONS Indoor unit i CEILING MOUNTED CASSETTE TYPE Kit name E Romak FCQ50KAVEA FCQ60KAVEA FCQ71KAVEA FCQ100KAVEA FCQ125KAVEA FCQ140KAVEA Decoration panel BYCP125K W1 Sealing material of air discharge outlet KDBH55K160F Panel spacer KDBP55H160FA Fresh air Chamber Without T joint pipe and fan KDDP55B160 intake kit type With T joint pipe without fan KDDP55B160K Direct installation type KDDP55X160 Chamber connection kit KKSJ55KA160 Insulation kit for high humidity KDTP55K80 KDTP55K160 High efficiency filter unit Colorimetric method 65 KAFP556B80 KAFP556B160 including filter chamber Colorimetric method 90 KAFP557B80 KAFP557B160 Replacement Colorimetric method 65 KAFP552B80 KAFP552B160 high efficiency filter Colorimetric method 90 KAFP553B80 KAFP553B160 Filter chamber KDDFP55B160 Branch duct chamber KDJP55B80 KDJP55B160 Remote contro
39. ize 0 75 1 25 mm Total length 500 m Installation service space for outdoor unit M For RZQS50 140AV1 RZQS100 140AY1 RZQ71 140LV1 1 When there is an obstruction on the inlet side 1 When the overhead space is open 1 For single unit installation When there is an obstruction only on the inlet side When there are obstructions on both sides 2 For series installation more than two units When there are obstructions on both sides 2 When there is an obstruction in the overhead space 1 For single unit installation 1000 or more When there is an obstruction on the An obstruction inlet side in the overhead space de O When there are obstructions av goo on the inlet side and both lateral sides An obstruction in the overhead space 2 For series installation more than two units When there are obstructions An obstruction l s in the overhead on the inlet side and PS spe both lateral sides jooo more s 1000 or more 100 or more 2 When there is an obstruction on the outlet side 1 When the overhead space is open 1 For single unit installation 2 For series installation more than two units in the overhead space 1 For single unit installation 1000 or more An obstruction in the overhead space 2 For series installation P Gi more than two units 100 or more C An obstruction in the overhead s
40. l Reuse of a Connection of pipe cleaning machine existing piping s Cleaning of piping Sag Carry in and installation of units Removal of pipe cleaning machine D WN Se Vd aere ee Paaa eS Removal of existing piping Airtightness test S er vog Carry in and installation of units Vacuum drying Carry in and installation of units v Airtightness test NN Test operation Airtightness test Quick Vacuum drying installation y a thanks to Quicker cleaning free Vacuum drying Test operation Test operation installation pipe reuse Upgrade to compact new outdoor unit Upgrade Pipes are buried and making new pipe installations difficult to new indoor Outdoor unit difficult to access v unit 6 Multiple units are being upgraded at the same time Bi Technology Advanced technology including use of corrosion resistant EEV acid neutralisers and improved compressor reliability enables the re use of existing piping without the need to flush the piping for a simplified replacement process Stronger refrigerating Highly corrosion resistant Highly reliable machine oil electronic expansion valve compressor Durability of compressor is improved by adoption of filter or accumulator to collect solid foreign substances An acid neutraliser agent is added to disable acids chlorine ions which cause corrosion Acid neutraliser iU C Filter or Acid chlo
41. ller Wireless type Heat pump BRC7F634F Navigation Remote Controller Wired type Nav Ease BRC1E62 Central remote controller DCS302CA61 Unified ON OFF controller DCS301BA61 Schedule timer DST301BA61 intelligent Touch Controller DCS601C51 Adaptor for wiring KRP1C63 Group control adaptor KRP4AA53 Installation box for adaptor PCB KRP1H98 Remote sensor for indoor temperature KRCSO01 4B Note Refer to page 10 for the details Required for installing high efficiency filter unit Wiring for wired remote controller to be procured locally The indoor unit is equipped standardly with the interface adaptor for SkyAir series An option is unnecessary Installation box for adaptor PCB KRP1H98 is necessary Round flow type List of optional parts required to achieve different flow patterns For each flow pattern all round 4 way 3 way 2 way branch duct connection the compatibility of each independently installed option shown in the column on the left to accessory options listed across the top of each table is shown in the cells where the relevant row and column intersect A circle O indicates compatibility and a cross X indicates incompatibility Any options not shown below are not suitable for independent or accessory installation All round flow 4
42. n 850 mm lift temperature sensors Temperature sensing can be set at the unit or to further improve comfort level closer to the target area at the wired remote control This feature requires initial setting by the installer Temperature sensor on indoor unit must be used when the air conditioner is controlled from another room Transparent d ral n socket a Wireless remote controller does not have a temperature sensor y e Hot start after defrost e Connection to a centralised control system is available no need for option card e Switchable fan speed High Middle Low Control of airflow rate has been improved from 2 step to 3 step e Low gas pressure detection Easier to maintain The condition of the drain pan and drain water can be checked by removing the drain plug and intake grille High efficiency filter Panel spacer Available in two types 65 and 90 colorimetry Use when only minimal space is available between drop ceilings and ceiling slabs Fresh air intake kit Using this kit a duct can be fitted to increase the intake of outdoor alr Note Connecting ducts insect nets fire dampers air filters and other Panel spacer parts should as required be procured locally Note Some ceiling constructions may hinder installation Outside Air fan interlocked with air conditioning unit is necessary Contact your Daikin Dealer before installing your unit Optio
43. nal PCB KRP 1C63 is required for interlocking It is recommended that the volume of outdoor air introduced through the kit is limited to 10 of the maximum airflow rate of the Sealing material of air discharge outlet Sealing material block air discharge openings not used in indoor unit Introducing higher quantities will increase the operating sound and may also influence temperature sending 2 way or 3 way blow Branch duct direct connection round duct A round duct can be attached without the need for a chamber A flanged port for direct connection of a round duct is provided An existing branch duct chamber can also be fitted square slit hole The units can be installed in the following different ways Chamber type Chamber type without T joint pipe and fan with T joint pipe and without fan Flexible duct procured locally Flexible duct T joint pipe procured locally T joint pipe Suction chamber Suction w chamber Intake duct Intake duct Connection procured locally Connection procured locally chamber duct length 4 m max chamber duct length 4 m max Note Use of options will increase operating sound Direct installation type KDDP55X160 Duct flange with insulation material Intake duct procured locally 10 CEILING SUSPENDED TYPE Comtortable airflow travels throughout the room Heat pump ETA FHQ71 100 125BW FHQ140CA NG
44. nd shape type EIS Notes Sticking location for manufacture s label manufacture s label for indoor unit Suction grille inner side s electric components box s lid surface manufacture s label for decoration panel Decoration panel s corner decoration cover inner surface In case of using wireless remote controller this position will be a signal receiver Refer to the drawing of wireless remote controller in detail When the temperature and humidity in the ceiling exceed 30 C and RH 80 or the fresh air is inducted into the ceiling or the unit continues 24 hour operation an additional insulation thickness 10mm or more of glasswool or polyethylene form is required Though the installation is acceptable up to maximum of 910mm square ceiling opening keep the clearance of 35mm or less between the indoor unit and the ceiling opening so that the panel overlap allowance can be ensured Please do not place the thing been damp and troubled under an indoor unit When the case where humidity is 80 or more and the drain outlet are choked up and the air filter are dirty dew may fall Liquid pipe connection Gas pipe connection Drain pipe connection Remote controller wiring connection Air outlet Suction grille Corner decoration cover 9 Drain hose accessory Transmission wiring connection 26 DIMENSIONS uni mm CEILING SUSPENDED TYPE FHQ71 125BWV1 A FHQ71BWV1A 1120 1160 FHQ
45. onnection Earth terminal inside the electric components box M4 Suspension bracket Backward pipe and wiring connection opening lid 60 Upward pipe and wiring connection opening lid Right side pipe connection Left back drain pipe connection 3 Left side drain pipe connection 4 Right side drain pipe connection 5 Hole of wall for taking out in piping back Upward drain pipe connection Upward gas pipe connection Upward liquid pipe connection FHQ140CAVEA 156 Ms 120 Connection position of fresh air intake kit 18 102 90 100 Knock out hole 9 I 57 e iem SS r1 e Sli LS ES ise tel ol MD o N LO N UN 8 2 Es COS D ET a C p ES 25 Y S 5a ER 5160 134 59 Nes 1 SE m ER 10 Position slit hole for taking out in piping back View from the front 3 z gt L 1550 S E Hanging bolt pitch o 5 690 g E Hanging bolt EI o E 4 M8 M10 4 5 1 c N 7 S 2 5 2 SS 57 ss Els 6 4 Position Hole of wall for taking out in piping back SS 57 58 2 E a 2 30 or more 1590 30 or more 045 View from the front ce c Service space Service space mi Gn s 2 The Front ZL Floor side En
46. pace 1000 or more 100 or more 3 When there are obstructions on both the inlet and outlet sides When the obstruction on the outlet side is higher than the unit itself 1 When the overhead space is open There is no limit to the height of the obstruction on the outlet side 1 For single unit installation L H 2 For series installation more than two units L H Note As for other patterns of installation please refer to Installation manual or Engineering Data Book 32 MEMO 34 7 DAIKIN Warning Ask a qualified installer or contractor to install this product Do not try to install the product by yourself Improper installation can result in water or refrigerant leakage electrical shock fire or explosion e Use only those parts and accessories supplied or specified by Daikin Ask a qualified installer or contractor to install those parts and accessories Use of unauthorised parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage electrical shock fire or explosion e Read the user s manual carefully before using this product The user s manual provides important safety instructions and warnings Be sure to follow these instructions and warnings If you have any enquiries please contact your local importer distributor and or retailer Cautions on product corrosion 1 Air condi
47. pawutugABosd aw HO 1 Jeuun ejnpeuos Aeon jes DUG Julodjas 1 1 asal opne lulodjos 1 uoneJedo 1einb 1U6IN a qeol dde Buljooo punojJ Je9A 1504J6p Joye MEIS 10H slosuos s1n eJodueo 9 qe199 8s OM 1 Aq SLUWEJBOJd spow peeds ue U IH aye MO Ie Ony deis peeds ue 9e qeuo1MS Buneeu uonounj uonueA aJd Wesq LLI af gt ke Q LLI ke E O al lt C c cu c 4 A a Tiz E c3 oF E QO Bulms ony easy Ins Features 7 f f lH f T i f Applicable when wired remote controller is used 2For the outdoor units sOption 13 z Compact amp Sophisticated design e FAQ100 FAQ100BV FAQ100C Height 360mm 340mm N 4 BAN Width 1 570mm BP 1 200mm 2 ZA 1 200mm 370mm shorter e Flaps neatly close when not in use 2 Comfortable e Auto swing up and Wide angle down and louvers wide angle louvers by hand Soft material louver bends airflow over a left and right by hand facilitate wider area even room temperatu re An air discharge Auto swing 5 level air direction set ing modes ensure comfortable air distribution across the entire room Gettable to 5 different levels e Comfort even on the far side of the room To carry air to the far side of long rooms extra high airflow adds 10 more fan speed the high s
48. pe e e WON Pol 157 Note 4 Si Note 4 SIS m 90 4 Connection position zt 4 E 4 a 157 j e 5 5 Connection position 183 of fresh air intake kit 196 anging bolt 350 D m Connection position 350 Connection position SIS of fresh air intake kit esr an inta l 4 M8 M10 280 of branch duct of branch duct EE direct installation type arrow view direct installation type C arrow view Connection position 330 round shape type A square shaped type SIS e of branch duct VME SI round shape type 5 4 FCQ100 140KAVEA FCQ100 140KAVEA PS H 16 M4 Prepared hole n i 3 PEM 840 55 Connection position 8 53 840 55 27 M4 Prepared hole S 11340 eee EL eA E Required space 1500mm or more gE eo 2x100 0 so auare Seed pe A 64 160 200mm or more Ss eg lu I EE p se LL LA 1500mm _ Tn Sli me T 1500mm jp 7 0 more z glo TEJ V SEET ormorex bi gt E mm 3 Ng m Ga 5 SY od or more 1500mm or more e 5 Bm The necessary space is 300mm or more when the olo 2001 35 or less 35 or less a Elle air outlet is blocked wi e accessory Dt l Des Note 4 zi 157 Note 4 amp S 5 Moreover when the corner areas are blocked anging bolt 350 Connection position 350 Connection position slo E 5 both right and left of the blocked air outlet A 4 M8 M10 280 4 d 2 of branch duct of branch di egg the necessary space is 200mm or more onnection position round shape type square shaped type IS 5 E of branch duct 330 E iis E rou
49. r embedded Leave it to Daikin Since Daikin can carry out upgrades using your existing piping you can get the work done faster than ever before Strict conditions must be adhered to please refer to the installation manual and Engineering Data Book for further details including pipe sizes if pipes are to be re used Enables Increased capacity amp Higher EER COP Upgrade to air conditioners featuring the latest technology and enjoy greatly improved energy efficiency FHYC71KVE FCQ125KAVEA MA Cooling Heating RY71KV1 RZQS125AV1 Cooling EER 2 41 Heating COP 2 55 Cooling EER 3 51 Heating COP 3 89 For example compared with R22 non inverter units of 15 years ago in the latest R410A series some units use smaller diameter piping which means they can achieve greater cooling capacity by reusing existing piping As a result the greater capacity units ensure better performance to cope with the increasing amount of heat generated by office equipment Only available with RZQS A series Simplified Installation Enables simplified air conditioner replacement with minimal impact on operations Conventional Installation process installation process for replacement If existing piping that can for replacement of be reused needs cleaning air conditioning Refrigerant recovery and units removal Refrigerant recovery and units removal Refrigerant recovery and units remova
50. rine ion E y Ae Compressor Refrigerant pipe Strict conditions must be adhered to please refer to the installation manual and Engineering Data Book for further details including pipe sizes if pipes are to be re used sJeBueuoxe 1eau pares u0IS0JJ09 uv 1 SYBJUI We useJJ Jew Aouerongje uBiH puepuejs uoneoiunululo9 3NHIIO O1 UOD HOO UI ROUND FLOW O1 UO9 ejouueJ e1u92 OJ1uO9 PUEWWOI eu149 X3 J9 OJ1u09 groe Aq joujuoo dno19 SJe OJ1UOO o1 ouJ8J z Aq JOYO J9 0 eBueuo Guneeu Buiooo oiny included Cables must be procured locally Wireless remote controller and signal receiver unit are sold as a set uelseJ oIny uonounj sisouBelp Jjas uoneJedo AoueGlsouj B uoinoejep 2 amssald seb mo Wired LCD remote controller Wireless LCD remote controller Heat pump uonue eud Guljios Dua Accessory required for indoor unit Option uis Jo w 0g 0 dn JO Dou Ald wsiueyssw duund ugi s standards ued uleJp EJS OBQq 1UE UO Jang jeyy Jie euejoeq nuy peuuueJ60Jd saw HO leul ejnpeuos AjyaaM jes obueu lulodieS 1999 ojne lulodjos uolieledo 1einb 1UBIN e qeoidde Buljooo punoJ Je9A tomorrow 1504J6p Joye MEIS 10H SIOsUuoSs 91n eloduo 9 qe199 8s OM uoneoidde Guljlso OD AJJ SLWWEJBOJd deis peeds ue a qeyoumMs Duneeu
51. rosion treated heat exchangers with special acryl pretreatment are used for the heat exchanger of the outdoor unit In high corrosive areas regular maintenance needs to be carried out SPECIFICATIONS i CEILING MOUNTED CASSETTE TYPE M_r Model Indoor unit FCQ50KAVEA FCQ60KAVEA FCQ71KAVEA FCQ100KAVEA FCQ125KAVEA FCQ140KAVEA FCQ100KAVEA FCQ125KAVEA FCQ140KAVEA Name Outdoor unit RZQS50AV1 RZQS60AV1 RZQS71AV1 RZQS100AV1 RZQS125AV1 RZQS140AV1 RZQS100AY1 RZQS125AY1 RZQS140AY1 Power supply 1 Phase 220 240 V 50 Hz 3 Phase 380 415 V 50 Hz Cooling capacity1 3 kW 5 0 6 0 7 1 10 0 12 5 14 0 10 0 1235 14 0 Rated Min Max 3 2 5 6 3 2 6 0 3 2 8 0 5 0 11 2 5 7 14 0 6 2 15 5 5 0 11 2 5 7 14 0 6 2 15 5 Heating capacity23 kW 6 0 7 0 8 0 11 2 14 0 16 0 11 2 14 0 16 0 Rated Min Max 3 5 7 0 3 5 8 0 3 5 9 0 5 1 12 8 6 0 16 2 6 2 18 0 5 1 12 8 6 0 16 2 6 2 18 0 Power consumption Cooling kW 1 27 1 67 1 84 2 57 3 56 4 40 2 57 3 56 4 40 Heating kW 1 41 1 74 1 79 2 77 3 60 4 38 2 77 3 60 4
52. t Reclaim Central remote controller option E Central remote controller option Ventilator O Q H H O O O O Zone link control by Cog TE Le He FE Le centralised control Heat Reclaim Heat Reclaim Ventilator Ventilator Heat Reclaim Ventilator for indoor units within a zone are operated by Heat Reclaim Ventilator for indoor units within interlocking Can also be operated independently by remote controller S a zone are operated by interlocking Note BRC1E62 can connect to BRC1E62 only t is not possible to use two wireless remote controllers 3 BRC1E62 cannot connect to wireless remote controller The ceiling mounted cassette type lt Round Flow gt ceiling suspended type 140CA only and wall mounted type come standard with an interface adaptor for SkyAir series Easily adaptable to large scale high function centralised remote control system Central remote controller Unified on off controller Schedule timer intelligi Controller DCS302CA61 Option DCS301BA61 Option DST301BA61 Option DCS601C51 Option Centralised control with a setting as Centralised control of on off geng Unified control of weekly schedule With its high functionality the full simple as it is with a standard group or all at once for up to 256 for up to 1 024 indoor units colour all in one graphic controller remote controller of up to 64 groups indoor units Schedule timer sets on off time in 1 minute units facilitates manag
53. talling for other than all round flow an air discharge outlet sealing material option must be used to close each unused outlet Operation sound increases when using 2 way or 3 way flow Grime prevention and antibacterial coating Makes cleaning easier lt External panels are treated with a coating that helps to repel dirt Treated Untreated surface surface o prevent dirt sticking to the external panels they have 1 O been coated with a surface e Sere e Condition after exposure E J to the smoke of 600 treatment SCH e cigarettes in 1 m nt p or a enclosed space e Silver ion anti bacterial e Non flocking flaps e Filter has anti mould and drain pan antibacterial treatment Mould proof drain pan includes a silver ion Condensation does not easily form on Helps prevents mould and antibacterial agent that assists in and dirt does not cling to non flocking microorganisms growing out of the dust preventing the growth of slime bacteria flaps and moisture and mould that cause smells and clogging It is easy to clean that adheres to the filters CEILING MOUNTED CASSETTE TYPE lt Round Flow lt Unified square panels m Compact body and quiet operation Panel size is the same for all models FCQ50 140KA dB It is easy to maintain a neat appearance when multiple Indoor unit High Middle gem units are installed in the same room 5OKA 35 315 28 60KA 35 31 5 28 71KA 5 1 5 2 Same for 3 3 8 Note Anechoi
54. tandard position when the unit is shipped from the factory The position can be changed from the remote controller Closing of the corner discharge outlets is recommended When the thermostat turns off e All models can be installed without e Suitable for high ceilings using lifter because of the light weight Even in spaces with high ceilings a comfortable airflow is carried down to e Can be installed in any direction the floor level Since the orientation installing the All round 4 way 3 way 2 way All round 4 way 3 way 2 way S flow flow flow flow flow flow unified when multiple mCriteria for ceiling height and number of air discharge outlets of the intake grill can Number of air disch tlets used RE umber OT air discharge outlets use direcion of ihe intake E Standard 2 7m 3 1m 3 0m 3 5m 3 2m 3 4m 3 6m units are installed A High ceiling 3 0 m 3 4 m 3 3 m 3 8 m 3 6 m 3 9 m 4 0 m 42m Ceiling height is reference value be adjusted after OE NA ODA ORA grill ines can be High ceiing 3 5 m 4 0m 35m j 42m 45m 42m e Drain pump is Note Factory settings are for standard ceiling height and all round flow High ceiling settings 1 and 2 are set with the remote controller by field setting equipped aS standard e wo selectable temperature sensors accessory with Both indoor unit and wired remote controller option BRc1Ee contai
55. tdoor unit mm 626 0 Hole Max interunit piping length m 50 Equivalent length 70 75 Equivalent length 90 Max installation level difference m 30 Heat insulation Both liquid and gas piping Inverter series ee ee 71 Model Indoor unit FCQ71KAVEA FCQ100KAVEA FCQ125KAVEA FCQ140KAVEA Name Outdoor unit RZQ71LV1 RZQ100LV1 RZQ125LV1 RZQ140LV1 Power supply 1 Phase 220 240 V 50 Hz Cooling capacity kW al 10 0 125 13 6 rated Min Mak 13 3 2 7 1 5 0 10 0 b 7 12 5 6 2 14 0 Heating capacity KW 8 0 112 14 0 16 0 rated Min Max 3 3 5 8 0 5 1 12 5 6 0 15 0 6 2 16 5 Power consumption Cooling kW 1 99 2 64 4 02 4 53 Heating kW 2 10 2 84 3 83 4 80 EER Cooling kW kW 3 57 3 79 3 11 3 00 COP Heating kW 3 81 3 95 3 66 SBS Indoor Colour Unit unit Decoration panel Fresh white Airflow rate H M L Lis 350 292 225 533 433 333 550 467 375 m min 21 17 5 193 5 32 26 20 33 28 22 5 Sound pressure level H M L 4 dB A 35 31 5 28 43 37 5 32 44 39 34 44 40 36 Sound power level H L 5 dB A 53 46 60 50 61 52 61 54 Dimensions Unit mm 256x840x840 298x840x840 HxWxD Decoration panel mm 50x950x950 Machine Unit kg 21 24 weight Decoration panel kg 5 5 Certified Indoor Cooling CWB 14 to 25 Operation Range Heating CDB 15 to 27 Outdoor Colour Ivory white unit Compressor Type Hermetically sealed swing type Hermetically sealed scroll type Motor output kW L 2 08 2 4 3 15 Refrigerant charge R 410A k 2 0 219 3 15 4 2 g Charged for
56. te the equipment locally or from a remote location Note When a wireless remote controller is used remote control by two remote controllers is not possible M Group control by 1 remote controller You can turn up to 16 indoor units on off with a single remote controller When using connected indoor units the settings must all be the same and on off will be simultaneous Options M High efficiency filter unit Applicable for ceiling mounted cassette type Two types are available 65 and 90 colorimetry Others gi Anti corrosion treated heat exchangers Note Some features only available on selected models See model pages for full list of features applicable to each unit M Low gas pressure detection Insufficient gas charging is normally hard to detect During post installation trials and regular inspection procedures the refrigerant level is monitored by a microprocessor to maintain proper gas pressure Reliability is assured and maintenance and inspection can be carried out more quickly M Emergency operation If there is a malfunction elsewhere in the system the fan or compressor can still be operated M Self diagnosis function The operating parameters of indoor and outdoor units and sensor data at critical locations throughout the system are constantly monitored using a microcomputer To facilitate a quick response in the event of a malfunction a message appears on the LCD of the remote controller and an LE
57. ter series Sound pressure level dB A Night Quiet Mode will initiate 8 hours after the peak RZQS50 60AV1 48 44 temperature is reached in the RZQS71AV1 50 46 daytime and normal operation TR 49 will resume 10 hours after that RZQS100AVI Y1 93 RZQS125AV1 Y1 54 50 Reducing noise will reduce capacity e slightly RZQS140AV1 Y1 54 e 50 RZQ71LV1 49 45 See ae RZQ100 125LV1 51 e 47 values are somewhat higher owing to ambient conditions Value when cooling Value will differ when heating RZQ140LV1 54 50 Reuse of existing piping Reduces replacement time amp cost by simplified installation When considering air conditioner replacement do the following things concern you M For how long will the business have to close down While replacement work is going on how will sales be affected M How to minimize inconvenience to tenants who only leave the space vacant on weekends EM Won t the costs be high and work period longer because scaffolding is necessary for pipe replacement Where feasible by reusing existing pipes we cut your work cost and reduce work time Normally when you replace air conditioners in addition to replacing indoor and CN outdoor units replacement of piping involves high costs and lengthy work periods 2 7 And the more installed units you have the greater the cost for connecting them especially if they are installed in high places o
58. ting for an increment of time that the remote controller is installed 16 C 20 C automatically turns off air conditioner after a preset period of at a place where any number of E CINES FS time for each time operation starts people may operate it Period can be preset from 30 to 180 minutes in10 minute increments 17 control configurations and control of multiple indoor units Convenience Weekly schedule Schedule nr 1 5 actions per day can be scheduled for each day of the week Ta Jet Gol Went The holiday function will disable schedule timer for the days that have been set as Mon 8 30 ON 2C __ 10 00 OFF C C CE 3 independent schedules can be set e g summer winter mid season 15 00 OFF C C Return Setting 4 College classroom sample a summer Monday case 1 8 30 ON 2 10 00 OFF ENNIO 4500 err The first period starts and the In the second period the classroom When the third period starts After the third period the classroom air conditioner starts the cooling is unoccupied and the air conditioner operation starts again becomes vacant again and the operation stops air conditioner stops Multilingual display Display is available in 11 languages English German French Spanish Italian Portuguese Greek Dutch Russian Turkish and Polish
59. tioners should not be installed in areas where corrosive gases such as acid gas or alkaline gas are produced 2 If the outdoor unit is to be installed close to the sea direct exposure to sea breeze should be avoided If you need to install the outdoor unit close to the sea contact your local distributor JMI 0107 Organization DAIKIN INDUSTRIES LTD AIR CONDITIONING MANUFACTURING DIVISION Scope of Registration THE DESIGN DEVELOPMENT AND MANUFACTURE OF COMMERCIAL AIR CONDITIONING HEATING COOLING REFRIGERATING EQUIPMENT HEATING EQUIPMENT RESIDENTIAL AIR CONDITIONING EQUIPMENT HEAT RECLAIM VENTILATION AIR CLEANING EQUIPMENT COMPRESSORS AND VALVES JQA 1452 Organization DAIKIN INDUSTRIES THAILAND LTD Scope of Registration THE DESIGN DEVELOPMENT AND MANUFACTURE OF AIR CONDITIONERS AND THE COMPONENTS INCLUDING COMPRESSORS USED FOR THEM All of the Daikin Group s business 9 gt 77 o CF d Certified System amp ISO 9 facilities and d 14001 subsidiaries in Japan d Quality e 4m 5 are certified under the Environment ISO 9001 o ir S0 14001 ISO 14001 Daikin Ei Mayr ja international standard D sch e Y Limite y Limite EC99J2044 for environment CEM20437 October 27 2006 QEC23256 May 31 2006 Sydney Brisbane Adelaide Melbourne Newcastle Townsville Perth Auckland management Sydney Brisbane Melbourne Adelaide DA
60. uid pipe connection Service port 4 Earth terminal 5 Refrigerant piping intake Power supply wiring intake Wiring between unit intake Drain outlet 9 Drain port 30 31 REMOTE CONTROLLER 4 Wireless type Remote controller dimensions DIMENSIONS whit mm Remote controller holder CEILING MOUNTED CASSETTE TYPE lt Round Flow gt Receiver installation procedure installation procedure lt installation to wall Receiver _ Transmitting part surface gt Refrigerant D SSC EX A T C
61. way flow i Optional accessory parts Panel spacer Wireless Fresh air intake kit Fresh air intake kit High humidity High efficiency ndependently installable optional parts remote controller Chamber type direct mount operation kit filter Panel grille related Panel spacer O O O X O Operation control related Wireless remote controller O O O O O Auxillary function related Fresh air intake kit Chamber type 1 2 O O X x O Fresh air intake kit direct mount O O X O O High humidity operation kit X O X O X Filter related High efficiency filter O O O O X 3 way flow 2 way flow Optional accessory parts Panel spacer Wireless Fresh air intake kit Fresh air intake kit High humidity High efficiency ndependently installable optional parts remote controller Chamber type direct mount operation kit filter Panel grille related Panel spacer O3 O3 Os X X Operation control related Wireless remote controller Os O O O X Auxillary function related Fresh air intake kit Chamber type 1 2 Os O X X X Fresh air intake kit direct mount Os O X O X High humidity operation kit X O X O X Branch duct connection Optional accessory parts Panel spacer Wireless Fresh air intake kit Fresh air intake kit High humidity High efficiency ndependently installable optional parts remote controller Chamber type direct mount operation kit filter Branch duct 1 way branch unit 3 way flow O O O O4 X X Chamber type 2 way branch unit 2 way flow X O O O4
62. xD mm 195x1 160x680 195x1 400x680 195x1 590x680 235x1 590x690 195x1 400x680 195x1 590x680 235x1 590x690 Machine weight kg 2f 32 35 38 32 35 38 Certified Cooling CWB 14 to 25 Operation range Heating CDB 15 to 27 Outdoor Colour Ivory white unit Compressor Type Hermetically Hermetically sealed scroll type sealed swing type Motor output kW 1 55 3 15 Refrigerant charge R 410A kg 2 9 4 0 4 2 4 0 4 2 Charged for 30 m Charged for 30 m Charged for 30 m Charged for 30 m Charged for 30 m Sound pressure Cooling Heating dB A 50 52 53 55 54 56 53 55 54 56 level Night quiet mode dB A 46 49 50 49 50 Sound power level Cooling Heating5 dB A 69 69 Dimensions HxWxD mm 990x940x320 1 430x940x320 Machine weight kg 75 108 Certified Cooling CDB 5 to 46 Operation range Heating CWB 15 to 15 5 Piping Liquid Flare mm 99 5 connections Gas Flare mm 915 9 Drain Indoor unit mm VP20 I D9 20xO D 26 Outdoor unit mm 626 0 Hole Max interunit piping length 50 75 m equivalent length 70 equivalent length 90 Max installation level difference m 30 Heat insulation Both liquid and gas piping I WALL MOUNTED TYPE ee Model Indoor unit FAQ71CVEA FAQ100CVEA FAQ100CVEA MELE Outdoor unit RZQS71AV1 RZQS100AV1 RZQS100AY1 Power supply 1 Phase 220 240 V 50 Hz 3 Phase 380 415 V 50 Hz Cooling capacity kW 7 1 10 0 Rated Min Max 3 2 8 0 5 0 11 2 Heating capacity23 kW 8 0 11 2 Rated Min Max 3 5 9 0 5