Home
ODP Series Linear Programmable DC Power Supply User Manual
Contents
1. O O oo 00 f Plus minus 5V 3A CH1 Para CH2 O O f O O f O Minus Ground Plus 4 6 System Menu Operation 1 Display the menu Press System key the System menu is shown on the screen 2 Choose the menu Press IA V direction key or turn the knob to move around the menu items Press any one of the lt direction key the PE key or the knob to enter the submenu to return to main menu press the direction key In the submenu press A Y direction key or turn the knob to move around the submenu items 3 Enter the menu Press the E key or the knob to enter the selected menu item 4 Exit the menu 14 Press System key to close the menu or the pop up box Note In this document System gt CH1 gt O V P means Enter the CH1 item in System menu and then choose the O V P submenu 15 5 Front Panel Operation This chapter will deal with the following topics mainly How to Turn On Off the Channel Output Set the Output Voltage Current Over Voltage Current Protection Timing Output Save Recall Record Functions System Settings How to Use Built in Help 16 5 1 Turn On Off the Channel Output O Independent Mode Press the orange ON OFF key to turn on off the Channel 1 output Press the blue ON OFF key to turn on off the Channel 2 output The ON OFF key is lighted whe
2. liquids or solvents Cleaning Inspect the instrument as often as operating conditions require To clean the instrument exterior perform the following steps 1 Wipe the dust from the instrument surface with a soft cloth Do not make any scuffing on the transparent LCD protection screen when clean the LCD screen Disconnect power before cleaning your instrument Clean the instrument with a wet soft cloth not dripping water lt is recommended to scrub with soft detergent or fresh water To avoid damage to the instrument do not use any corrosive chemical cleaning agent ZN Warning Before power on again for operation it is required to confirm that the instrument has already been dried completely avoiding any electrical short circuit or bodily injury resulting form the moisture 29
3. The parameters of the O V P O C P set in normal status take effect in normal status The parameters of the O V P O C P set in timer status take effect in timer status Note In Plus minus mode if either of the Positive or Negative output voltage current reaches its own O V P O C P the instrument will disable the output 5 3 1 Set O V P 1 Enter the O V P setting menu Independent Mode Press the System key enter System gt CH1 CH2 gt O V P O Parallel Series Mode Press the System key in normal status enter System gt O V P in timer status enter System gt Pro Set gt O V P O Plus minus Mode Press the System key enter System gt Positive Negative gt O V P 2 A setting box pops up press the A key to switch the state of the O V P between 18 ON or OFF the O V P in current mode and status is enabled or disabled Note In Plus minus mode the O V P status of Positive and Negative will remain consistent you can set either of them The O V P value can be set separately 3 Use the numeric keys to enter the O V P value in current mode and status The maximum in Independent Parallel Plus minus mode is 31 5V the maximum in Series mode is 63V Press the key to confirm 5 3 2 Set O C P 1 Enter the O C P setting menu Independent Mode Press the System key enter System gt CH1 CH2 gt O C P O Parallel
4. Off the Channel Output on P17 and Set the Output Voltage Current on P17 4 4 1 Voltage Output Inspection The following steps verify basic voltage functions without load 1 When the instrument is under no load power on it make sure that the output current setting value of each working mode is none zero 2 Turn on the channel output The ON OFF and Volt CV key is lighted which indicates the channel you opened is in Constant Voltage output mode 3 In each working mode set some different voltage values check if the actual voltage value displayed is close to the set voltage value and to check if the actual current value displayed is nearly zero 4 Check that if the output voltage can be adjusted from zero to the maximum rating 4 4 2 Current Output Inspection The following steps check basic current functions with a short across the power supply s output 1 Power on the instrument 2 Connect a short across and output terminals with an insulated test lead Use a 12 wire size sufficient to handle the maximum current 3 Set the output voltage to the maximum rating 4 Turn on the channel output The ON OFF and Curr CC key is lighted which indicates the channel you opened is in Constant Current output mode 5 In each working mode set some different current values check if the actual current value displayed is close to the set current value and to check if the actual voltage
5. P 0 0008 155 5 000v 1 000A 0 000v 0 000A Oorr 15 00v EX oFF 1 5004 Figure 4 3 User interface in Independent mode Channel 2 same layout as Channel 1 Output status of Cannel 1 Specified time and left time of current output when the timing output of Channel 1 is on Actual output value of power for Channel 1 Timing output mode of Channel 1 Sequence Loop Timer range of Channel 1 The parameter number of the current output when the timing output of Channel 1 is on Set values of voltage and current for Channel 1 Actual output values of voltage and current for Channel 1 Status and set values of O V P and O C P for Channel 1 in current status as ojej e ejejeje eS Status icons see Status Icons on P10 for more details O Parallel Series Mode Q 630 O 0 000w XA orr 1 500A Figure 4 4 User interface in Parallel Series mode e D Maximum ratings of voltage and current 2 Channel status 3 Output mode of timing output Sequence Loop Timer range The parameter number of the current output when the timing output is on Specified values of voltage and current Specified time of current output when the timing output of is on Left time of current output when the timing output of is on 9 Specified values of voltage and current that will be output at the next fixed times when the timing output
6. groups with configurable timer high resolution LCD display extremely clean ripple and noise comprehensive over voltage over current over temperature protection user friendly interface and panel layout and variety standard interfaces to meet diverse test requirements Features and benefits 4 Dual Independent amp Separate Control Outputs Outstanding line regulation rate lt 0 01 3mV voltage lt 0 1 3mA current Outstanding load regulation rate lt 0 01 3mV voltage lt 0 2 3mA current Low ripples noise lt 300 uVrms 2 mVpp Four operating mode independent parallel connection series connection plus minus Up to 100 groups time settings High precious resolution output 3 9 inch high resolution 480 320 pixels TFT LCD display Interface USB2 0 RS232 4 Quick Start This chapter will deal with the following topics mainly Front Rear Panel Overview User Interface Overview How to Implement General Inspection How to Implement Power On Check How to Implement Output Inspection Instruction of the four Working Mode Instruction of the System Menu Operation 4 1 Front Rear Panel and User Interface 4 1 1 Front Panel OWON ODP3032 POWER ON Dual Channels With 5V Fixed 0090 O 5V 3A CH1 Para O CcH2 0 09090 Q D Figure 4 1 Front panel overview take ODP3032 for instance LCD Display the user interfa
7. parameters In timer status press the Set key to enter exit timer setting interface of the current mode Press the key to switch between the corresponding timer setting interface of the four working mode Output time Number Voltage Current Editing value 1 998 Page number Channel 1 Channel 2 same layout as Channel 2 Figure 5 1 Timer Setting Interface in Independent Mode The selected parameter will be highlighted In Independent mode or Plus minus mode press orange ON OFF key to select the left parameter area press blue ON OFF to select the right parameter area Press the la M key to change the parameter item After selecting the parameter use the numeric keys to enter a desired value press the l key to confirm Press the gt l key to go to the previous or next setting page 20 Note e If the input value exceeds the rating of current working mode the system will change it to the maximum rating automatically after pressing the key to confirm e Inthe Plus minus mode the values of the Negative and Positive output time remain consistent you can set either of them 5 4 3 Timer Range Timer range setting denotes that you can set the last number of timer parameter group and output mode You can find out the TimerRng submenu of system menu only in timer status If turn on the timing output the system will output the pre set parameters between 0 and the se
8. to avoid short circuiting to the interior of the device or electric shock please do not operate in a humid environment Do not operate in an explosive atmosphere In order to avoid damages to the device or personal injuries it is important to operate the device away from an explosive atmosphere Keep product surfaces clean and dry To avoid the influence of dust or moisture in air please keep the surface of device clean and dry 2 Safety Terms and Symbols Safety Terms Terms in this Manual The following terms may appear in this manual A Warning Warning indicates the conditions or practices that could result in injury or loss of life A Caution Caution indicates the conditions or practices that could result in damage to this product or other property Terms on the Product The following terms may appear on this product Danger It indicates an injury or hazard may immediately happen Warning It indicates an injury or hazard may be accessible potentially Caution It indicates a potential damage to the instrument or other property might occur Safety Symbols Symbols on the Product The following symbol may appear on the product A Hazardous Voltage AN Refer to Manual D Protective Earth Terminal rh Chassis Ground oa i Public Ground 3 General Characteristics OWON ODP Series products are new high performance programmable linear DC power supplies The excellent features of this series include up to 100 output
9. value displayed is nearly zero 6 Check that if the output current can be adjusted from zero to the maximum rating 7 Turn off the channel output and remove the short wire from the output terminals 4 5 Working Mode ODP Series are designed with four working modes Independent Parallel Series and Plus minus Press the key to switch between the four working modes For the instructions of the user interfaces in the four working mode please see User Interface on P7 4 5 1 Icons and Ratings The status icons and voltage current ratings of the four mode is listed below Independent Parallel Series Plus minus Voltage rating 0 30V 0 30V 0 60V o 30V wate 0 02 3A 0 1 6A 0 02 3A 0 02 3A Current ratings ODP3052 0 02 5A 0 1 10A 0 02 5A 0 02 5A Current ratings The 5V output terminals always output fixed 5V during the instrument is powered on the max output current is 3A ODP3032 or 5A ODP3052 Users could choose the proper mode and output terminals as required 4 5 2 Connections Take ODP3032 for instance Independent 5V 3A CH1 Para O cH2 0 O O O O 13 Parallel 5V 3A CH1 Para O cH2 0 O O O O a Note In parallel mode CH1 is main channel and CH2 is auxiliary channel To ensure normal output please connect the load to the main channel Connecting to auxiliary channel could not ensure normal output Series 5VI3A CH1 Para O CH2
10. OWON ODP Series Linear Programmable DC Power Supply User Manual E ODP3032 E ODP3052 WWW OWON COM HK Apr 2014 edition V1 5 4 Copy Right in this Manual Lilliput Company All Rights Reserved The Lilliput s products are under the protection of the patent rights in America and other countries including ones which have already obtained the patent rights and those which are applying for The information in this manual will replace all that in the materials published originally The information in this manual was correct at the time of printing However OWON will continue to improve products and reserves the rights to changes specification at any time without notice OWON is the registered trademark of the Lilliput Company Headquarter Fujian Lilliput Optoelectronics Technology Co Ltd The mansion of optoelectronics 19 Heming Road Lantian industrial zone Zhangzhou Fujian China Tel 86 596 2130430 Fax 86 596 2109272 Web www owon com hk Mail Business Consulting info owon com hk Sale service service owon com hk Branch Xiamen Lilliput Technology Co Ltd the 5th floor B Area Chuangxin Mansion Software Park ZhenZhuWan Huandao RD Xiamen Fujian China Tel 86 592 2575666 Fax 86 592 2575669 General Warranty Lilliput warrants that the product will be free from defects in materials and workmanship for a period of 2 years 1 year for accessories from the date of purchase of the product by the original purchas
11. Series Mode Press the key in normal status enter System gt O C P in timer status enter System gt Pro Set gt O C P O Plus minus Mode Press the System key enter System gt Positive Negative gt O C P 2 A setting box pops up press the A key to switch the state of the O C P between ON or OFF the O C P in current mode and status is enabled or disabled Note In Plus minus mode the O C P status of Positive and Negative will remain consistent you can set either of them The O C P value can be set separately 3 Use the numeric keys to enter the O C P value in current mode and status The maximum in Independent Series and Plus minus mode is 3 15A the maximum in Parallel mode is 6 3A Press the a key to confirm 5 4 Timing Output The timing output function can preset up to 100 groups of timing parameters When you turn on the timing output the instrument will output the pre specified voltage current in pre specified time You can set special O V P O C P for timer status see Over Voltage Current Protection for more details 5 4 1 Enter Exit Timer Status Press Timer to enter exit timer status The 4 icon identifies the system is in timer status 19 5 4 2 Timer Setting Before turning on the timing output you should set the timer parameters including voltage current and output time This function allows up to 100 groups of timer
12. The buzzer is on e The buzzer is off O The system is in Timer Status 4 2 General Inspection After you get a new ODP Series power supply it is recommended that you should make a check on the instrument according to the following steps 1 Check whether there is any damage caused by transportation If it is found that the packaging carton or the foamed plastic protection cushion has suffered serious damage do not throw it away first till the complete device and its accessories succeed in the electrical and mechanical property tests Check the Accessories The supplied accessories have been already described in the Appendix A Enclosure of this Manual You can check whether there is any loss of accessories with reference to this description If it is found that there is any accessory lost or damaged please get in touch with the distributor of Lilliput responsible for this service or the Lilliput s local offices Check the Complete Instrument If it is found that there is damage to the appearance of the instrument or the instrument can not work normally or fails in the performance test please get in touch with the Lilliput s distributor responsible for this business or the Lilliput s local offices If there is damage to the instrument caused by the transportation please keep the package With the transportation department or the Lilliput s distributor responsible for this business informed about it a repairing o
13. ce 2 Numeric keys area Parameter input include the numeric keys decimal point and backspace key 3 Up and down Select menu or change the parameter direction key Enter key Enter menu or confirm the parameter entered 6 Knob Select menu or change the parameter pressing it has the same effect as pressing the enter key Left and right Select menu or move the cursor direction key System key Enter the system menu Timer key Enter exit timer status O Help key View the built in help Channel 2 control area Blue Volt CV key Set the output voltage of Channel 2 Blue Curr CC key Set the output current of Channel 2 Blue ON OFF key Enable disable the output of Channel 2 4D Output terminals Channel 2 output connectors of Channel 2 42 Mode key Switch the working mode between Independent Parallel Series and Plus minus 39 Output terminals Channel 1 output connectors of Channel 1 5V output Output fixed 5V max output current is 3A 5A for ODP3052 terminals 5 Power button Turn on off the instrument Channel 1 control Orange Volt CV key Set the output voltage of Channel 1 area Orange Curr CC key Set the output current of Channel 1 Orange ON OFF key Enable disable the output of Channel 1 9 Function keys IRecord key Record the current output data as a txt file and save to USB disk Recall key Recall the stored settings fi
14. corner Choose the Communications Ports Settings to set the corresponding communication parameters After connect successfully the connection information in the bottom right corner of the software will turn green To learn about how to operate the software you can choose Communications Help Help to open the help file ES OFON Digit Power Software 1 0 0 AAA Language Help gt Platform Common Y OFF P 0 000 305 000V 0 500A A Miis 0 000V 0 000A V Independent Parallel A Em5 500v XA Series 5355 o00v_ o 500a Plus minus 0 000V 0 000A Lem 5 500v E 0 600A auto synchro COMMON INDEPENDENT 1 1 1 5 000 0 500 O 000 0 000 5 500 0 600 1 1 1 5 000 0 500 automatically check USB amp Figure 6 1 The Power Supply connects with PC successfully 25 7 Troubleshooting 1 The instrument is powered on but no Display Check if the power is connected properly Check if the Power Switch is in the proper voltage scale Check if the fuse which is below the AC Power socket is used appropriately and in good condition the cover can be pried open with a straight screwdriver Restart the instrument after the steps above If the problem still exists please contact Lilliput for our service 2 The output is abnormal Check if the output voltage is set to OV If so set it to other value Check if the output current is set to OA If so set it to othe
15. e knob to set the selected value Press the lt gt key to move the cursor Press the key to confirm 5 6 5 Buzzer Press the System key and enter System Sys Set Buzzer Press the key to turn on off the buzzer When the buzzer is on an icon 2 will be shown on the status bar You will hear a key tone once a key is pressed down when the system prompts the instrument will make a buzzing sound e g cutting off the output due to O V P O C P When the buzzer is off an icon A will be shown on the status bar 5 6 6 View System Information Press the System key and enter System gt Sysinfo You can view the Serial Number Software Version and Hardware Version 5 6 7 Set as Default Press the key and choose System gt Default press the key to use the factory defaults see table below Working Mode Independent Plus minus Parallel Series Parameter CH1 CH2 Negative Positive Voltage 5V 5V 12 V 15 V 12 V 12 V Current 0 5AJ O05A 1A 1 5 A 0 5A 0 5A Normal tatis O V P value 55VW 55VW 12 5V 15 5V 12 5V 12 5V O C P value 0 6A 0 6A 1 1 A 1 6 A 0 6 A 0 6 A O V P O C P status OFF OFF OFF OFF OFF OFF 23 O V P value 15V 15V 12V 24 V 12V 12 V Ti acs O C P value 15A LSA 15A 15A O5A 0 5 A status O V P O C P status OFF OFF OFF OFF OFF OFF Menu Item Defaults Bri
16. er from the Lilliput Company This warranty only applies to the original purchaser and is not transferable to the third party If the product proves defective during the warranty period Lilliput either will repair the defective product without charge for parts and labor or will provide a replacement in exchange for the defective product Parts modules and replacement products used by Lilliput for warranty work may be new or reconditioned to like new performance All replaced parts modules and products become the property of Lilliput In order to obtain service under this warranty Customer must notify Lilliput of the defect before the expiration of the warranty period Customer shall be responsible for packaging and shipping the defective product to the service center designated by Lilliput and with a copy of customer proof of purchase This warranty shall not apply to any defect failure or damage caused by improper use or improper or inadequate maintenance and care Lilliput shall not be obligated to furnish service under this warranty a to repair damage resulting from attempts by personnel other than Lilliput representatives to install repair or service the product b to repair damage resulting from improper use or connection to incompatible equipment c to repair any damage or malfunction caused by the use of non Lilliput supplies or d to service a product that has been modified or integrated with other products when the effect of such mod
17. ghtness 9 Screen Saver OFF Buzzer ON 5 7 Use Built in Help 1 Press Help function button the catalog will display in the screen 2 Press the A W 3 Press the 4 key to view the details about the topic press the the catalog 4 Press Help again to exit the help or just do other operations 24 key or turn the knob to choose help topic key to go back to 6 Communication with PC ODP Series Power Supply supports communications with a PC through USB or COM interface You can use the ODP communication software to set the parameters control the output of the power supply and synchronously display the actual output values on the Power Supply screen 1 2 Install the software Install the ODP communication software on the supplied CD Connect the instruments Use a USB data cable to connect the USB Device port in the rear panel of the Power Supply to the USB port of a PC Or use a data cable to connect the COM port in the rear panel of the Power Supply to the COM interface of a PC Install the driver When the Power Supply is turned on a dialog will appear on the PC screen and guide you to install the USB driver The driver is in the USBDRV folder under the directory where the ODP communication software is installed such as C Program Files ODP USBDRV Use the software Run the ODP software click the Menu button in the top right
18. ification or integration increases the time or difficulty of servicing the product Please contact the nearest Lilliput s Sales and Service Offices for services or a complete copy of the warranty statement For better after sales service please visit www owon com hk and register the purchased product online Excepting the after sales services provided in this summary or the applicable warranty statements Lilliput will not offer any guarantee for maintenance definitely declared or hinted including but not limited to the implied guarantee for marketability and special purpose acceptability Lilliput should not take any responsibilities for any indirect special or consequent damages Table of Contents 1 General Safety Requirements vic sicvssiiscsesvceccanasdenaisaceaadevarienebasasecesasisenauoedceadeossisuebbasnns 1 2 Safety Terms GNG SYMDOIS i ii asin a a e da 2 3 General Characteristics ccs0scccssssccssscccssssccssscccsscccasscccssccanssccssssccassscassensasscsacasceees 3 O AA A NT 4 4 1 Front Rear Panel and User Interface ssssccccccsssssssseecececccecsssseececececsacsssseececeeeeeacanes 5 LAO Panel ia a a tooo 5 A Pae ORO 7 AUS A A A SO laa 7 SAUS ICO tia A A AAA AR AA AA DAR ERED 10 4 2 General INSpectioncicccieissieieciiccctedccscesiecececdeinecctedcssceebecaced eddavecee ssasccdedceadiedcaveceescasecse 11 ERAS A A 11 43 11 AC PoWer Input Setting 3 ccsctsosschseesaccetes aada ssiecesessevevesduasesassienovesdhe
19. le Save key Save the current setting parameters Set key Enter exit the setting interface of timing output Instructions for panel key indicator ON OFF key The indicator will be lighted after you turn on the channel Volt CV key The indicator will be lighted when the channel is in Constant Voltage output mode blinking indicates you are setting the output voltage through the input box Curr CC key The indicator will be lighted when the channel is in Constant Current output mode blinking indicates you are setting the output current through the input box 4 1 2 Rear Panel Figure 4 2 Rear panel overview USB Host port Connect as a host device with an external USB device such as connect a USB disk to the instrument 2 USB Device port Connect as a slave device with an external USB device such as connect the instrument to a PC 3 COM port Connect the instrument with external equipment as serial port Power socket AC input connector Fuse Use the specified fuse according to the voltage scale Power switch Switch between 110V and 220V D Fan Fan inlet 4 1 3 User Interface The below figures are the interfaces in Timer status you can consult the following instructions for the interfaces in Normal status too O Independent Mode 00 on lt 1 000V 2 000A on 0 000v 0 000A AA JOFF 2 000v XA OFF 1 000A OFF
20. n the corresponding channel is on O Parallel Series and Plus minus Mode Press the orange ON OFF key to turn on off the channel output The blue ON OFF key is invalid 5 2 Set the Output Voltage Current You can set the output voltage current through input box About the rated range of each mode please refer to cons and Ratings on P13 Note The output voltage current cannot be set in Timer status If you want to set it you should exit the Timer status first Independent mode 1 Press the orange Volt CV o voltage current will pop up Curr CC key the input box of Channel 1 output 2 The key light will start blinking indicating to input there are two methods to change the value Modify Turn the knob or press the A V direction key to change the value by the unit of cursor position hold down the A V direction key to change continuously Press the lt gt key to move the cursor Input Use the numeric keys to enter a desired value the original value will be cleared and display the value you entered 3 Press the 4 key to confirm In the same way press the blue Volt CV or Curr CC key to set the output voltage current of Channel 2 O Parallel Series mode 1 Press the orange Volt CV or Curr CC key the input box
21. nt data of the channel can be recorded into a txt file which stored in USB disk 1 Press the Record key press the numeric keys to set the interval 2 Press the J key to start recording During recording an icon Y is shown on the status bar 3 Press the Record key again to stop recording 5 6 System Settings You can set the system by operating the System Menu It is suggested that you should read the System Menu Operation on P14 first so as to be familiar with the menu operation 5 6 1 Set Language Press the System key and enter System gt Language choose the desired language The supported languages include Chinese English and so on 22 5 6 2 Set Bright Press the System key and enter System gt Display gt Bright Press the key or turn the knob to adjust the screen brightness 1 10 5 6 3 Set Screen Saver Time The screen saver will run automatically if no operation is taken for any key within the set time Press any key to resume Press the System key and enter System Display gt ScrSaver Press the lt gt key or turn the knob to adjust the screen saver time 1 99 minutes When it is set to 00 the screen saver is disabled 5 6 4 Set System Time Press the System key and enter System Sys Set gt SysTime Press the A key or turn th
22. of is on Status and set values of O V P and O C P in current status 4D Actual output values of voltage current and power 12 Status icons see Status Icons on P10 for more details e Plus minus Mode lt 5 25 00V ee 0 000v O TA NAG OFF 12 00v XA JOFF 0 500A FF P 0 0008 1 000 2 0012 0 000v 0 000A Figure 4 5 User interface in Plus minus mode Positive same layout as Negative Q Output status of Negative same as Positive Specified time and left time of current output when the timing output of Negative is on Actual output value of power for Negative Timing output mode of Negative Sequence Loop same as Positive Timer range of Negative same as Positive The parameter number of the current output when the timing output of Negative is on same as Positive Set values of voltage and current for Negative Actual output values of voltage and current for Negative Status and set values of O V P and O C P for Negative in current status 0 lS9 ejolsio OO Status icons see Status Icons on P10 for more details Status Icons Icons Instruction Connect as a slave device with PC Recording the current output A USB device is detected GOO Current working mode is Independent GBS current working mode is Parallel 10 JE SOS Current working mode is Series GiGi Current working mode is Plus minus
23. of output voltage current will pop up 2 The operation of input box is the same as Independent mode O Plus minus mode 17 1 Press the orange Volt CV o voltage current will pop up Curr CC key the input box of Negative output 2 The operation of input box is the same as Independent mode In the same way press the blue Volt CV or Curr CC key to set the Positive output voltage current Note If the input value is out of the rated range the box prompts ERROR you need to input another value within the rated range In Series mode the minimum rating of the current is 0 1A in other modes is 0 02A 5 3 Over Voltage Current Protection When the Over Voltage Protection O V P or Over Current Protection O C P is enabled once the output voltage current reaches the set value of O V P O C P the instrument will cut off the output The value of O V P O C P which causes cutting off will turn red and flashing the instrument will make a buzzing sound if the buzzer is turned on Note When the instrument disables the output due to protection after you make some adjustments the channel must be restarted to output normally This function can keep the power output from exceeding the load rating in order to protect the load The O V P O C P can be set separately for the four working mode and for different status normal timer You can enable or disable these functions as required
24. oid any contingent danger this product is only used within the range specified Check AC power input setting according to the standards in your own country see Page 11 AC Power Input Setting Only the qualified technicians can implement the maintenance To avoid Fire or Personal Injury Use Proper Power Cord Use only the power cord supplied with the product and certified to use in your country Product Grounded This instrument is grounded through the power cord grounding conductor To avoid electric shock the grounding conductor must be grounded The product must be grounded properly before any connection with its input or output terminal Check all Terminal Ratings To avoid fire or shock hazard check all ratings and markers of this product Refer to the user s manual for more information about ratings before connecting to the instrument Do not operate without covers Do not operate the instrument with covers or panels removed Use Proper Fuse Use only the specified type and rating fuse for this instrument Avoid exposed circuit Do not touch exposed junctions and components when the instrument is powered Do not operate if in any doubt If you suspect damage occurs to the instrument have it inspected by qualified service personnel before further operations Use your instrument in a well ventilated area Please keep well ventilated and inspect the intake and fan regularly Do not operate in wet conditions In order
25. r replacement of the instrument will be arranged by the Lilliput 4 3 Power On Check 4 3 1 AC Power Input Setting ODP Series adopt 110V 220V AC power source Users should regulate the voltage scale of the Power Switch according to the standards in their own country see Figure 4 2 at the rear panel and use an appropriate fuse 11 Fuse Voltage ODP3032 125V F5A 250V F3A To change the input voltage scale of the instrument do the following steps 1 Turn off the power button at the front panel and remove the power cord 2 Check if the fuse installed before leaving factory 250 V F3 A can match with the selected voltage scale if not pry the cover open using a straight screwdriver see in Figure 4 2 change the fuse 3 Regulate the Power Switch to the right voltage scale 4 3 2 Power On 1 Connect the instrument to the AC supply using the supplied power cord ODP3052 125V F10A 250 V F5A AC110V AC220V Warning To avoid electric shock the instrument must be grounded properly 2 Press down the power button at the front panel the orange and blue key is lighted the screen shows the boot screen 3 Press any key to enter 4 4 Output Inspection Output inspection is to ensure that the instrument can achieve its rated outputs and properly respond to operation from the front panel For the procedures below it is suggested that you read Working Mode on P13 Turn On
26. r value When in timer status check if there is any voltage current value of timer setting is set to O If so set it to other value If the problem still exists please contact Lilliput for our service 3 Cannot identify the USB device correctly Check if the USB device is in good condition Check if the used USB device is a flash device note a hard disk cannot be supported Restart the instrument and insert your USB flash device again If the problem still exists please contact Lilliput for our service 26 8 Technical Specifications The specifications below are based on the instrument having run for at least 30 minutes continuously under the specified operating temperature Channel 1 Channel 2 Fixed 5V Independent Parallel 0 30V Voltage Series 0 60V 5V Plus minus 30V 30V Independent Series er DC Output Ratings ODP3032 Plus minus 3A Parallel O 6A Current Independent Series DEJEN ODP3052 Plus minus 5A Parallel 0 10A CV lt 0 01 3mV lt 3mV Line Regulation CC lt 0 1 3mA CV lt 0 01 3mV lt 0 1 3mV Load Regulation CC lt 0 2 3mA lt 300 Noise and Ripple CV lt 300 uVrms 2 mVpp uVrms 20Hz 7MHz 2 mVpp cc lt 3mArms Voltage 1mV None Settings Resolution Current 1mA None Settings Accuracy Voltage lt 0 05 3mV None 25 C 5C Current lt 0 1 3mA None 1mV lt 10V Read Back Voltage 10mV gt 10V None Resolution Cu
27. rrent 1mA None Read Back Accuracy Voltage lt 0 05 3 digits None 25 C 45 C Current lt 0 1 3 digits None 2T Display Display Type 3 9 inch colored LCD Liquid Crystal Display Display Resolution 480 Horizontal x 320 Vertical Pixels Display Colors 65536 colors TFT screen Power Supply 110 Vac 10 220 Vac 10 AC input 50 60Hz 110V 125 V FSA ODP3032 Za E 220V 250 V F3A Fuse 110V 125 V F10A ODP3052 A RR A oO 220V 250V F5A Environment Temperature Working temperature 0 C 40 C Storage temperature 20 C 60 C Relative Humidity lt 90 Height Operating 3 000 m Non operating 15 000 m Cooling Method Fan cooling Mechanical Specifications Dimension 298mmx202mmx450mm W H D Weight About 9 8 kg Interval Period of Adjustment One year is recommended for the calibration interval period 28 9 Appendix 9 1 Appendix A Enclosure Standard Accessories A power cord that fits the standard of the destination country A USB data cable A CD PC link application software A User Manual 9 2 Appendix B General Care and Cleaning General Care Do not store or leave the instrument where the liquid crystal display will be exposed to direct sunlight for long periods of time Caution To avoid any damage to the instrument do not exposed it to any sprays
28. s In Normal Status press the Savel key to save the parameters about current working mode and the output voltage current the O V P O C P of current mode You can name the setting files This function is not available in Timer Status 1 In Normal Status press the Savel key to enter the function interface press it again to exit Press the A Y key to choose the storage location as Local or UDisk Turn the knob to change the selected character in Save name input box Press the key to add the next character Press the key to select the previous character Press the key to delete the selected character 2 Press the key to store after editing the file name 5 5 2 Recall and Delete System Parameters File 1 Press the Recall key to enter the function interface press it again to exit Press the Al key to choose the storage location Press the key to show the list of system parameters files 2 The list displays the file name and stored date Turn the knob or press the lA V key to select a file and then press the J key 3 Two options appear on the screen Load and Delete Turn the knob or press the key to switch between the options Press the J key to confirm 5 5 3 Record the Output You have to insert a USB disk before using this function By pressing the Record key the curre
29. sdighdkdvevesdiassiesddesovessiasese 11 AZ 2 POWER OM osc dict sate vena ce cnsedgstes cess A A Snide oud dale Ba Daten debe eae Oa 12 AA Output INSPECTION sser renna r sliced bicceedsscadeescs slecveds Scccvedsslecsdecoovadsccotuessoeess 12 AAAN oltage OUTPUT INSPECTION mi A accuse seas A 12 4 42 Current OUTPUT Inspection aaea eea aaae Laai obits sagasa uous obi ogabesstouessbusadsdownsee 12 AS Working Mode oi chad EE E NEES EEES s 13 ASV ICONSANG RATINGS iia iia 13 U RSOP COMMECUTIOINS A A oxic busby dates ous dew se A A anodes E 13 4 6 System Menu Operation iscsscceccccccsedeiiaccecssieceedetsadeed Soateees edeceedelsccsecsscostessiccosdedsotseessconvs 14 5 Front Panel Operation issiccssscenvssieessccastaceasatcsentacesssscnadccavedcesasascdecsvovesceassseaseescstace 16 5 1 Turn On Off the Channel Output cccecececececececececececececececeeeeeeeeeeeeeeeeeseseeeeenesesenenes 17 5 2 Set the Output Voltage Current cococonononononononononononononanononenenenenenenenenerenonenenenenenenenenen 17 5 3 Over Voltage Current Protection coconononononononanonanononanononononenenonenenenenenenenenenenenenenenen 18 EA A A O NN ONE 18 RA EN A ENTORNO 19 5 4 Timing QUEUE sisscesiecsscccsissctencceesecesnssecesdeveccewssvsansvesvedcevashensscuebeucevsseasscosuscesuesenseccosvens 19 5 4 1 Enter Exit Timer Status ccccccccscccccccccssssccccssssecsssessccssseseceesseceeesssessssesueeeuseseeessuesuseeeesauessesseaans 19 54 2 Timer Sette
30. sii siciaaerea case FS se Soci vn SASS ti 20 BAS TIME MIRAN BE RR RN 21 SA4 Turn ON OFF TIMING OUDE A A cia 21 5 5 Save ReCall RECOP AAA NN 21 5 51 Save System Parameters sorketa ai 22 5 5 2 Recall and Delete System Parameters File occccnonocooncnncnocononannnononncnonnnononncnncnnonnnnnnnnnccnnanonos 22 5 5 3 Record the OUTDUT ii atada 22 ARA ES 22 Bul Set Language ii Inia 22 OZ SOL Bist A A REN AS dis as 23 SS Saver TIME snidani evs aa aaae dbbsnebh ani ASE i deiTe ras 23 EA P aT N A RE E AA edit 23 A A N A O O 23 56 6 View System INformations a aaa o A a a a E A SEEEN ei 23 5 6 7 Set s A eiiis ae ae aRts E KEEN ER ESE EERE EEA E EE EREA EE iE 23 5 7 Use Built in Heliconia ccoo icon cena cecbecissctos daeduccbdesedcees sedeeadendacceeteese 24 6 Communication With PC 2ccccsscccnsscccnsscccnsscccnsscccassccanssccssssccssssccsssscesscssasscacassceees 25 J AVOUDICSNOOUNG sr deis 26 8 TECONICOES Pee ICAO 1 a a a aaiae lave 27 APPEAR A a E A AAA 29 9 1 Appendix Ar ENCIOSUTE ccsciciicccecksicceeded cisedc sieceedeisedecstsacuesdodesvedsisadeeedsceevsdsicoosdsccetstedscee s 29 9 2 Appendix B General Care and Cleaning cccccsssscccsssssceccssssceccsssceccsssscessesssesseessseeees 29 11 1 General Safety Requirements Before any operations please read the following safety precautions to avoid any possible bodily injury and prevent this product or any other products connected from damage In order to av
31. t number at sequence or loop mode 1 In timer status O Independent Mode Press the System key enter System gt CH1 CH2 gt TimerRng O Parallel Series Mode Press the System key enter System gt TimerRng O Plus minus Mode Press the System key enter System gt Positive gt TimerRng 2 The timer range setting box pops up Use the numeric keys enter a number 0799 press the A M key to switch between Sequence and Loop press the key to confirm 5 4 4 Turn On Off Timing Output In timer status O Independent Mode Press orange ON OFF key to turn on off the timing output of Channel 1 Press blue ON OFF key to turn on off the timing output of Channel 2 O Parallel Series or Plus minus Mode Press orange ON OFF key to turn on off the timing output Note In the process of timing output closing the channel output will reset the timer turning on the channel again will restart the timing output and the timer 5 5 Save Recall Record ODP Series support operations with a USB flash device and local file storage including store recall and delete current setting parameters The current data of the channel can be recorded into a txt file which stored in USB disk You can connect the USB disk to the USB Host interface in Figure 4 2 After connecting the USB disk successfully an icon 21 K will be shown at the top of the screen 5 5 1 Save System Parameter
Download Pdf Manuals
Related Search
Related Contents
Shark GI472H Iron User Manual Edimax ES-3124RL 24 Ports Switch Specification Sheet En juin 2014 (179) : Interventions sur la lame de coupe : prudence User Manual 6502 Electronic Pipettor II - 1 mL FR Pipette DPS202 Guide - Brahler ICS UK Ltd. BUS for SIGHTSEEING 2008 OPERATING INSTRUCTIONS Istruzioni Apparecchi CCM Determinazione del - cpm Descargar MANUAL TECNICO MOTOR NILO Copyright © All rights reserved.