1. CONGRATULATIONS to the purchase of your new professional switch mode battery charger This charger is included in a series of professional chargers from CTEK SWEDEN AB and represents the latest technology in battery charging SUPPLY PLUG MAINS CABLE CTEK COMFORT CONNECT CC Din aa Ra Dm CTEK COMFORT CONNECT eyelet M6 CTEK COMFORT CONNECT clamp Supply plugs may differ to suit your wall socket 20015436F XC 0 8 Manual EU Print file 002 indd 3 CHARGING 1 Connect the charger to the battery 2 Connect the charger to the wall socket The error lamp will indicate if the battery clamps are incorrectly connected The reverse polarity protection will ensure that the battery or charger will not be damaged z 3 Follow the indication lamps through the charging process The battery is fully charged when MM is lit 4 Stop charging at any time by disconnecting the mains cable from the wall socket DESULPHATION BULK FULLY CHARGED ABSORPTION PULSE MAINTENANCE CHARGING ERROR LAMP EN 3 2011 06 29 15 13 54 TECHNICAL SPECIFICATIONS Charger model Model number Rated Voltage AC Charging voltage Start voltage Charging current Current mains Back current drain Ripple Ambient temperature Charger type Battery types Battery capacity Dimensions Insulation class Weight XC 0 8 1054 220 240VAC 50 60Hz 7 2V 2 0V 0 8A max 0
2. necessary to keep the battery fully charged EN 5 2011 06 29 15 13 54 CONNECT AND DISCONNECT THE CHARGER TO A BATTERY INFO Ifthe battery clamps are incor rectly connected the reverse polarity protection will ensure that the battery and charger are not damaged For batteries mounted inside a vehicle 1 Connect the red clamp to the bat tery s positive pole 2 Connect the black clamp to the vehicle chassis remote from the fuel pipe and the battery 3 Connect the charger to the wall socket 4 Disconnect the charger from the wall socket before disconnecting the battery 5 Disconnect the black clamp before the red clamp Some vehicles may have posi tively earthed batteries 1 Connect the black clamp to the bat tery s negative pole 2 Connect the red clamp to the vehicle chassis remote from the fuel pipe and the battery 3 Connect the charger to the wall socket 4 Disconnect the charger from the wall socket before disconnecting the battery 5 Disconnect the red clamp before the black clamp Comfort Connect 6 EN 20015436F XC 0 8 Manual EU Print file 002 indd 6 S AFETY The charger is designed for charging 6V lead acid batteries Do not use the charger for any other purpose Check the charger cables prior to use Ensure that no cracks have occurred in the cables or in the bend protection A charger with damaged cables must be scrapped Never charge a da
3. 2A rms at full charging current lt 1Ah month lt 4 20 C to 50 C output power is reduced automatically at high temperatures 4 step fully automatic charging cycle All types of 6V lead acid batteries WET MF Ca Ca AGM and GEL 1 2 100Ah 142 x 51 x 36mm Lx W x H IP65 0 3kg Back current drain is the current that drains the battery if the charger is not connected to the mains CTEK chargers has a very low back current The quality of the charging voltage and charging current is very important A high current ripple heats up the battery which has an aging effect on the positive electrode High voltage ripple could harm other equipment that is connected to the battery CTEK battery chargers produce very clean voltage and current with low ripple 4 EN 20015436F XC 0 8 Manual EU Print file 002 indd 4 ERROR LAMP If the error lamp is lit check the following Is the chargers positive lead connected to the batterys positive pole Connect the charger according to page 6 FULLY CHARGED EO READY TO USE The table shows the estimated time for empty battery to 80 charge lt a KS BATTERY SIZE Ah TIME TO 80 CHARGED 2Ah 2h 8Ah 8h 20Ah 20h 60Ah 60h 2011 06 29 15 13 54 CHARGING PROGRAM XC 0 8 is equipped with a multi purpose charging program XC 0 8 charges all batteries 1 2 100Ah in the temperature range of 20 to 50 C 4 F to 122 F DESULPHATION BUL
4. K ABSORPTION PULSE ___ w S 8 Ko 2 3 z A Z Hi a a v 7 2V Increasing voltage 7 2V 6 4V 7 2V to 7 2V Declining current 0 8 0 4A 0 8A LIMITED WARRANTY CTEK SWEDEN AB issues this limited warranty to the original purchaser of this product This limited warranty is not transferable The warranty applies to manufacturing faults and material defects for 5 years from the date of purchase The customer must return the product together with the receipt of purchase to the point of purchase This warranty is void if the battery charger has been opened 20015436F XC 0 8 Manual EU Print file 002 indd 5 handled carelessly or repaired by anyone other than CTEK SWEDEN AB or its authorised repre sentatives CTEK SWEDEN AB makes no war ranty other than this limited warranty and is not liable for any costs other than those mentioned above i e no consequential damages Moreover CTEK SWEDEN AB is not obligated to any war ranty other than this warranty STEP 1 DESULPHATION Detects sulphated batteries Pulsing cur rent and voltage removes sulphate from the lead plates of the battery restoring the battery capacity STEP 2 BULK Charging with maximum current until approximately 80 battery capacity STEP 3 ABSORPTION Charging with declining current to maxi mize up to 100 battery capacity STEP 4 PULSE Maintaining the battery at 95 100 capacity The charger monitors the battery voltage and gives a pulse when
5. hat they can use the battery charger safely Store and use the battery charger out of the reach of children and ensure that children cannot play with the charger Connection to the mains supply must be in accordance with the national regulations for electrical installations 2011 06 29 15 13 55 20015436F CTEK PRODUCTS ARE PROTECTED BY Patents EP10156636 2 pending US12 780968 pending EP1618643 US7541778B2 EP1744432 pending EP1483817 pending SE524203 US7005832B2 EP1716626 pending SE526631 US7638974B2 EP1903658 pending EPO9180286 8 pending US12 646405 pending EP1483818 SE1483818 US7629774B2 EPO9170640 8 pending US12 564360 pending SE528232 SE525604 SUPPORT Designs RC US US US US RC RCI RC RC RC RCI RC RC D 509617 D575225 D571179 D580853 D581356 D 321216 D 000911839 D 081418 D 001119911 0001 D 00111991 1 0002 D 081244 D 321198 D 321197 ZL 200830120184 0 ZL 200830120183 6 RC RCI US US RC US RC D 000835541 0001 D 000835541 0002 D596126 D596125 D 001705138 0001 D29 378528 pending D 201030618223 7 pending 2011 02 04 Trade marks CTM 669987 CTM 844303 CTM 372715 CTM 3151800 CTM 1461716 pending CTM 1025831 CTM 405811 CTM 830545751 pending CTM 1475420 pending CTM 1935061 pending CTM 1042686 CTM 1082141 pending CTM 2010004118 pending CTM 4 2010 500516 pending CTM 410713 CTM 2010 05152 CIM 766840 pending CTEK offers a professional c
6. maged battery Never charge a frozen battery Never place the charger on top of the battery when charging Always provide for proper ventilation during charging Avoid covering the charger A battery being charged could emit explosive gasses Prevent sparks close to the battery When batteries are reaching the end of their lifecycle internal sparks may occur All batteries fail sooner or later A battery that fails during charging is normally taken care of by the chargers advanced control but some rare errors in the battery could still exist Don t leave any battery during charging unattended for a longer period of time Ensure that the cabling does not jam or comes into contact with hot surfaces or sharp edges Battery acid is corrosive Rinse immediately with water if acid comes into contact with skin or eyes seek immediate medical advice Always check that the charger has switched to jij before leaving the charger unat tended and connected for long periods If the charger has not switched to jij within 40 hours this is an indication of an error Manually disconnect the charger Batteries consume water during use and charging For batteries where water can be added the water level should be checked regularly If the water level is low add distilled water This appliance is not designed for use by young children or people who cannot read or understand the manual unless they are under the supervision of a responsible person to ensure t
7. ustomer support www ctek com For latest revised user manual see www ctek com By e mail info ctek se by telephone 46 0 225 351 80 by fax 46 0 225 351 95 By mail CTEK SWEDEN AB Rostugnsvagen 3 SE 776 70 VIKMANSHYTTAN SWEDEN VIKMANSHYTTAN SWEDEN 2010 05 01 n Jarl Uggla President CTEK SWEDEN AB 20015436F XC 0 8 Manual EU Print file 002 indd 7 EN 7 2011 06 29 15 13 55
Download Pdf Manuals
Related Search
Related Contents
Photographies pour tous - La Gazette de l`Hôtel Drouot Philips AZ6840 User's Manual BENDIX BW1578F User's Manual Philips SJA7186 Cell phone Slim Black Pouch 816 ug complete.P65 Infos techniques - Natureobaignades, fournitures pour les piscines GE AGM14 Air Conditioner User Manual Instrucciones de servicio FlexiGuard Portable C-Frame Rail Fall Arrest System Manual Copyright © All rights reserved.