1. gt mel OPERATING MANUAL MINI AC LEAKAGE CURRENT METER CMP 200 CE Version 1 7 The CMP 200 digital clamp meter has been designed for the purpose of clamp measurements of alternative leakage current Main features of the CMP 200 device are the following high resolution up to 0 1mA AC auto power off 3 digits display white LED backlight 1 2 jaw diameter safe protected clamp jaws double molded housing TABLE OF CONTENTS 1 INTRODUCTION 2222220222 22222200 0220 4 2 SA e 5 3 PREPARATION OF THE TESTER FOR OPERATION osiiccssscosscsscssssecncssbanscessencsesssecesesesonsesss 6 4 FUNCTIONAL DESCRIPTION e eere 7 5 MEASUREMENTS eee ee ee eee en eee 000000 9 5 1 AC CURRENT MEASUREMENTS eere nnne 9 5 2 DATA HOLD FUNCTION 5 3 BACKLIGHT DISPLAY 5 4 DATA MAX HOLD FUNCTION eee nene nana aaa 10 6 REPLACEMENT OF THE BATTERIES 11 7 CLEANING AND MAINTENANCE 11 8 STORAGE sviss pene 11 9 DISMANTLING AND UTILIZATION 11 10 8 22 2 222 22 2 12 10 1 TECHNICAL DATA aia 10 2 STANDARD EQUIPMENT 10 3 MANUFACTURER ecce etre rine 1 Introduction We appreciate your having purchased our digital clamp AC leakage current tester The CMP 200 meter is a modern high quality
2. realise the following actions e sure the conditions of the batteries or accumulators per mit to realise measurements e sure the casing of the tester is not damaged 4 Functional description 31531 IN3Y8N9 39WAV31 CMP 200 N current clamp rotational selector e OFF tester off 200mA 2A 200A measurement ranges HOLD button Data Hold function Back Light function LCD display clamp trigger data MAX hold function 5 Measurements 5 1 AC current measurements WARNING Do not take current readings on circuits where the maximum current potential is not known Do not exceed the maximum allowable input range while measuring current WARNING Do not realise measurements if the battery compartment is open In order to realise a measurement of alternative current it is necessary to realise the following actions e Set the Function switch to desired range if the range of the measured is not known select the highest range first open the clamp and place it properly on a cable Li read the result of the measurement on the display e move to the lower range if necessary Attention During measurements of the current make sure the clamp is properly placed Otherwise the results of the measurements will not be exact The most exact result we will get if the wi
3. 1 10 2 Standard equipment The standard set provided by the manufacturer includes the fol lowing components e The CMP 200 tester e 1 5V AAA battery 2 pieces e Operating manual e Warranty card 10 3 Manufacturer The manufacturer of the device which also provides guarantee and post guarantee service is the following company SONEL S A ul Wokulskiego 11 58 100 Swidnica Tel 48 74 858 38 60 Fax 448 74 858 38 09 E mail export 2sonel pl Web page www sonel pl Note Service repairs must be realised solely by the manufactur er Made in China for SONEL S A 13
4. ertainty 199 9mA 0 1mA 5 m v 8 digits 1 999A 0 001A 5 m v 10 digits 199 9A 0 1A 2 5 m v 10 digits e frequency range 45 65Hz Other technical data a Measurement category acc with EN 61010 1 2004 II 600V b Ingress protection in acc with PN EN 60529 c Pollution degree eerte rnnt d Power supply enne two 1 5V AAA batteries e Clamp size mean nana 30mm 1 2 f Overrange OL displayed g Display rate 2 readings second nominal h Display societ der LCD 3 digit 1999 count i Dimensions erret 182 x 61 x 34 mm j Weigh including batteries Operating temperature and humidity A OC to 30 C 32 to 86 F max 90 12 30 C to 40 C 86 F to 104 F max 75 40 C to 50 C 104 F to 122 F max 45 Storage temperature and 20 to 60 C 4 to 140 max 80 m Max operating altitude 3000m 10000ft Auto FR sinaia ee tinea caiete beata a aaa dei aa approx 15 minutes o Compliance with the requirements specified in the following NOMS f cea saga cae ina iap is EN 61010 1 2004 a EN 61010 2 032 p Quality standard ISO 900
5. measuring device which is easy and safe to use Please acquaint yourself with the present manual in order to avoid measur ing errors and prevent possible problems related to operation of the tester In the present manual we apply three kinds of warnings These are texts in frames which describe possible dangers both for the user and the tester itself The messages starting from the word WARNING describe situations which imply a risk for life or health should the recommendations presented in the present manual not be observed The word ATTENTION introduces a description of a situation where non observance of the recommendations presented in the present manual may imply damage for the tester Indications of possible problems are preceded by the word Attention WARNING Before using the instrument acquaint yourself with the pre sent manual and observe the safety regulations and recom mendations specified by the manufacturer WARNING The purpose of the CMP 200 tester is to realise clamp meas urements of the leakage current Using the tester in a man ner which does not comply with the recommendations speci fied in the present manual may lead to its damage and con stitutes a source of a serious risk for the user WARNING The CMP 200 tester may be operated solely by qualified and properly authorised personnel for work at electric installa tions Using the tester by unauthorised personnel may lead
6. re is placed in the middle of clamp Refer to the diagrams below for examples of the tester s appli cations Leakage current measurements Load current measurements 5 2 DATA HOLD Function To freeze the LCD tester reading press the HOLD button The word HOLD will appear on the LCD while the tester is in the Data Hold mode To release the Data Hold function and return the tester to normal operation press the Hold Backlight key again The word HOLD will switch off 5 3 Backlight display Press and hold the HOLD button key for more than 2 seconds to turn on the backlight This will also activate the Data Hold function To release the Data Hold function and return the tester to normal operation press the HOLD button momentarily To turn off the backlight press and hold the HOLD button for more than 2 seconds 5 4 DATA MAX HOLD Function To freeze the max reading on the LCD press the MAX button The word MAX will appear on the LCD while the tester is in the Max hold mode To release the tester to normal operation press the MAX button 10 6 Replacement of the batteries The CMP 200 tester is supplied by means of two 1 5V AAA bat teries It is recommended to use alkaline batteries Attention When making measurements with a battery s mnemonic on one must take into account additional indefinite measure ment uncertainty or unstable working of the meter In order to replace the battery it is neces
7. sary to do the following place rotational selector in the position OFF and remove the one rear Phillips head screw open the battery compartment and replace the required two 1 5V AAA batteries re assemble the tester 7 Cleaning and maintenance The casing of the tester may be cleaned with a soft damp cloth using all purpose detergents Do not use any solvents or cleaning agents which might scratch the casing powders pastes etc The electronic system of the tester does not require maintenance 8 Storage In the case of storage of the device the following recommenda tions must be observed Make sure the tester and its accessories are dry In the case the tester is to be stored for a prolonged period of time the battery must be removed from the device 9 Dismantling and utilization Worn out electric and electronic equipment should be gathered selectively i e it must not be placed with waste of another kind 11 Worn out electronic equipment should be sent to a collection point in accordance with the law of worn out electric and electronic equipment Before the equipment is sent to a collection point do not dis mantle any elements Observe the local regulations concerning disposal of packages worn out batteries and accumulators 10 Attachments 10 1 Technical data e m v means the measured value of standard AC current measurement Range Resolution Basic unc
8. to its damage and constitutes a source of a serious risk for the user 2 Safety In order to guarantee proper operation and correctness of the ob tained results it is necessary to observe the following recommenda tions Before commencing operation of the tester please acquaint yourself thoroughly with the present manual The instrument should be operated solely by properly qualified personnel who also must be trained regarding the industrial safety regulations Use great care when making measurements if the voltages are greater than 25V AC rms or 35V DC These voltages are consi dered a shock hazard Set function switch to the appropriate position before measur ing Do not exceed the maximum allowable input range It is prohibited to operated the tester lfitis damaged and completely or partially out of order lf it has been stored for an excessive period of time inad equate conditions e g if it is humid Repairs must be realised solely by an authorised service work shop WARNING Do not realise measurements with wet hands WARNING Do not realise measurements in environments in which there are inflammable gases Otherwise operation of the tester under such conditions may cause sparking and explosion 3 Preparation of the tester for operation Having purchased the tester examine completeness of the con tents of the package Before measurements commence it is necessary to
Download Pdf Manuals
Related Search
Related Contents
PDFW77(J) 取扱説明書 HP LE1901wi (PACS/REPORT)機能仕様 Untitled データシート - B&K Precision GS728TS, GS728TPS, GS752TS, and GS752TPS Smart Switch Manual - Cameramanager go! with the K-EP104LWE Targus A7™ Backpack VM touch - Bosch Solar Energy Delegacion de Atribuciones en el Consejo Delegado de Gestion Copyright © All rights reserved.