1. Check the connection between the door lock and the 100R 100V 220V Sones 100v 220V i DC 12V Connecting a Door Lock Power Fail Safe Mode A K 100V 220V 100V 220V Connecting a Door Lock Power Fail Secure Mode Power Supply 5 Installation See page 6 of this manual 35 Star 100R aPAss P100R The connection between a door lock and the 100R may vary depending UU on the door lock type and its operation type Normal Open Normal Close e f this does not solve the problem proceed with the following steps Check the door lock operation and the connection between the door lock and the 100R 1 Check the condition of the connection cable a short circuit or cut between the door lock and the 100R 2 Check the door lock operation When using a measurement device such as an oscilloscope or multi meter make sure to consult with technician eu Remove the door lock from the 100R and check the relay output from the 100R with a measuring instrument 0 When the relay output from the 100R is normal replace the door lock Caution See Installation to connect the door lock e f the problem still persists contact our customer service center P Installation See page 6 of this manual 36 Star 100R ipass IP100R 16 Warranty Policy and Limitation of Liability IDTECK warrants this product against defects in material and wor
2. 12V Power Supply Connecting a External Reader Check the exit reader operation 1 Check the condition of the connection cable a short circuit or cut between the exit reader and the 100R 2 Check if any noise occurs in the communication cable between the exit reader and the 100R Caution When using a measurement device such as an oscilloscope or uti multimeter make sure to consult with technician Check the exit reader output by checking the Wiegand communication cable with a measuring instrument Check the Wiegand output by consulting the Exit Reader s Manual If the Wiegand is not normal replace the exit reader Check if any noise comes from the Wiegand communication cable with a measuring instrument If a noise exists in the Wiegand communication cable enhance the GND signal by using the shield wire and a spare wire of the cable as GND Recommendation Do not try to extend the max transmission range for a Wiegand communication cable or stabilize signals by using a repeater 34 Star 100R 5 4 55 1 IP100R Caution See Installation to connect the exit reader e f the problem still persists contact our customer service center e Problem A door lock will not work e Cause gt An error in connection between the door lock and the 100R gt A door lock error gt System malfunction data damaged or lost due to an external noise or a short circuit e Solution
3. Configuration PIN to complete the registration Fewer arn 1 6 ag PIN Configuration PIN User Access PIN Configuration PIN again to complete the registration 4 The first 4 6 digit PIN becomes the Configuration PIN and the subsequent 4 6 digit PINs are registered as User Access PINs Once all User Access PINs have been registered enter the Configuration PIN again to complete the registration Please store the Configuration PIN for future changes 5 Now the Main Unit is entered into the normal operation mode with factory defaulted settings 10 4 Registration of RF PIN Combination MODE 1 Apply 12V DC to the unit All 3 LEDs will be flashing with a power up melody Press o 5 e from the keypad RF PIN Combination Mode Present Configuration Card to register Configuration Card to the unit Present RF Card or enter 4 6 digit PIN number to register user access card or PIN Present Configuration Card to complete the registration 2 3 4 5 snm 2 A c A e S SN 12 Star 100R ipass IP100R Configuration Card or or or Configuration Card PIN PIN PIN 10 5 Factory Defaulted Setting Values After the Initial Setup the Main Unit uses the factory defaulted setting values below to execute the normal operation mode You may want to change these factory setting values or modify your User Access list refer to section 12 for instructions on how to customize the operation of your unit 2 When User Access Card or PIN
4. TTL 06 OM 06 tt is the activating time value seconds tt value 00sec means from 01sec to 99sec no operation PW is the 2 digits Password for Do not use 77 for PW as it is Duress Alarm used for Secure Mode mm is activating time value minutes mm value 00min means from 01min to 99min no operation 12 21 Change Door Open Time When User Access Card or PIN Is Granted tt 00 99 sec Defaulted Door Open time 03 sec Configuration Card Command Door open time TTL time Configuration PIN 12 22 Change Alarm Time When User Access Card or PIN Is Denied Refer to Table 1 for OM tt 00 99 sec Defaulted Alarm time 02 sec ous Configuration Card Command Output Mode Door time Alarm Time TTL time Configuration PIN 18 Star 100R ipass IP100R 12 23 Change Alarm Time When Try Out Error Detected Refer to Table 1 for OM tt 00 99 sec Defaulted Alarm time 10 sec oaen Configuration Card Command Output Mode Door time Alarm Time TTL time Configuration PIN 12 24 Change Alarm Time When Door Contact Error Detected Refer to Table 1 for OM tt 00 99 sec Door Open Time out setting is required for activating refer to 12 81 DON O Configuration Card Command Output Mode Door time Alarm Time TTL time Configuration PIN 12 25 Change Alarm Time When AUX Input 1 Detected 12 26 Change Alarm Time When AUX Input 2 Detected 12 27 Change Alarm Time When AUX Input 3 Detected R
5. a secure location for future changes 5 Now the Main Unit is entered into the normal operation mode with factory defaulted settings 10 2 Registration of RF Cards with PINs for RF CARD PIN MODE 1 Apply 12VDC to the unit All 3 LEDs will be flashing along with a powered up melody do mi sol me do do mi sol do 2 Press 0 2 Ewr from the keypad RF CARD PIN MODE 3 Present RF Cards as follow to register Configuration Card and User Access Cards 4 6 digit 11 Star 100R IDTECK 55 1 Personal Identification Number PIN for each User Access Card 2 S Configuration Card User Access Cards PINs Configuration Card again to end task 4 The first card read becomes the Configuration Card and the following RF Cards PINs are registered as User Access Cards with assigned PINs Once all User Access Cards and PINs have been registered present the Configuration Card again to complete the registration Please keep the Configuration Card in a secure location for future changes 5 Now the Main Unit is entered into the normal operation mode with factory defaulted settings 10 3 Registration of PIN ONLY MODE 1 Apply 12VDC to the unit All 3 LEDs will be flashing along with a powered up melody do mi sol me do do mi sol do 2 Press 0 3 from the keypad PIN ONLY MODE 3 Enter to register Configuration PIN then to register for each subsequent User Access PIN at a time and then enter the
6. Card Command Cards to be registered 12 12 Add User Access Cards RF CARD PIN MODE ENT 2 4 Configuration Card Command Cards to be registered Configuration Card 12 13 Add User Access PIN PIN ONLY MODE Configuration PIN Command PINs to be registered Configuration PIN 12 14 1 Delete User Access Cards RF CARD ONLY MODE amp RF CARD PIN MODE one A A Configuration Card Command Cards to be deleted snake Configuration Card 12 14 2 Delete User Access PIN PIN ONLY MODE DO Configuration PIN Command PINs to be deleted Configuration PIN 12 15 Add User Access Card PIN RF PIN Combination Mode A 3 on p Em Or Or o Configuration Card Command PIN PIN Configuration Card 17 Star 100R IDTECK 1 55 TABLE 1 SETTINGS FOR COMMAND Symbol Setting Values Examples Remarks You must add value 1 and 2 EX1 Activate Door Relay In Safe amp Secure Mode Safe amp Secure Mode 50 Activate only in Secure Mode Door Feii 01 i Voor nelay Ul Activate in Safe amp Secure Mode Output OM 51 Mode Setting Value for activating Output Port om foo ae 2 Activate Output Port Activate only Door Relay Activate only Alarm Relay Activate only TTL Output Activate Door Relay amp TTL Activate Alarm Relay amp TTL Setting value for activating time D Activate Mode EX2 Activate Alarm Relay amp TTL only in Secure mode D Secure Mode 0 2 Alarm Relay amp
7. Close Door Unconditional Configuration Card Configuration PIN 4 2 Jer 12 43 Enable QUICK ACCESS MODE When QUICK ACCESS MODE is enabled Door will open simply by press ENT key Configuration Card IConfiqu ation PIN 4 3 20 Star 100R IDTECK 1 55 12 44 Disable QUICK ACCESS MODE Configuration Card Configuration PIN aa Jen Defaulted setting Disable 12 45 Enable Toggle Mode for Lock Control If you set Enable Toggle Mode Door will be toggled dc open and close function when the registered card or PIN entered You may use this function for Arm Disarm for buglar alarm system Configuration Card 12 46 Disable Toggle Mode for Lock Control Configuration Card 12 47 Enable Lock followed by Door Contact If you set Enable Lock followed by Door Contact Door only be locked followed by Door Contact so the door will remain open until the door is completely closed Configuration Card 12 48 Disable Lock followed by Door Contact Configuration Card 12 51 Disable Melody Sound Configuration Card 0 PIN 12 52 Enable Melody Sound Configuration Card Defaulted setting Enable Configuration PIN 21 Star 100R ipass IP100R 12 60 Change Keypad Lock out Time When Try Out Error Detected mmz00 99 min Defaulted Keypad Lock out timez 01 min e 0 ENT ma ENT Command Keypad Lock out time Configuration PIN 12 61 Set AUX Input 1
8. Korea Telephone 82 2 2659 0055 HQ 82 32 671 5642 RMA Center Fax 82 2 2659 0086 HQ 82 32 671 5641 RMA Center Website www idteck com e Training Center www idtecktraining com 38 e gt 6 32 hole 1 2 hole 6 32 hole Star 100R ipAss 8 The specifications contained in this manual are subject to change without notice at any time 5 Ace Techno Tower B D 684 1 Deungchon Dong Gangseo Gu Seoul 157 030 Korea Tel 82 2 2659 0055 Fax 82 2 2659 0086 E mail webmaster idteck com MAM100RHESX Dec 2008 Copyright IDTECK Co Ltd
9. Port of Personal Computer Install and run STAR 100R Application Software 9 10 Chime Bell Connection Separate purchase required Connect wire of Chime Bell unit to Bell Output Brown White wire of Main Unit Connect wire of Chime Bell unit to Power GND wire 10 Initial Setup The Flash memory of each shipped STAR 100R contains a minimum set of defaulted values but it does not have any other preprogrammed values or user s data in it therefore Initial Setup is required upon the first time the unit is powered up in order to operate the unit properly 10 1 Registration of RF Cards for RF CARD ONLY MODE 1 Apply 12VDC to the unit All 3 LEDs will be flashing along with a powered up melody do mi sol me do do mi sol do 2 Press 0 1 from the keypad RF CARD ONLY MODE 3 Present RF Cards as follow to register Configuration Card and User Access Cards a 5 Configuration Card User Access Cards Configuration Card again to end task NOTE The user may choose to register the 8 digit card numbers via the keypad instead of presenting the cards to the unit this implies that the user must know the 8 digit representation of each card 4 The first card read becomes the Configuration Card and the following RF Cards are registered as User Access Cards Once all User Access Cards have been registered present the Configuration Card again to complete the registration Please keep the Configuration Card in
10. SJ O3 S Exit Button 11 4 Action and Alarm Caused by Unregistered Card or PIN When an unregistered Card or PIN is read thus access is denied and the Alarm can be activated for 2 seconds along with sol do sol do melody A 025 Unregistered Card or PIN If you do not want to activate the Alarm in case of unregistered access attempt then you can change this setting as shown in section 12 11 5 Secure Mode The last person to exit can change the operation of the unit from Normal Mode to Secure Mode by entering the Secure Code of onto the keypad 2 Change to Secure Mode The Secure Mode will revert back to the normal mode when a registered card or PIN is presented entered 11 6 DURESS Alarm In case of Duress enter the 2 digit Duress Password 2 the door will open as usual however the Duress Alarm TTL Output will activate an external Auto Dialer to notify the appropriate personnel See section 9 7 and 12 29 for more instructions on this feature 14 Star 100R ipass IP100R 11 7 Chime Bell Operation The key can be used to activate an external Chime Bell for 5 seconds the defaulted value BELL 12 Setting Changes Configuration Card PIN is required to change existing or defaulted setting values or to manage user s access First present the Configuration Card or enter the Configuration PIN and enter the 2 digit command code RF Only Mode or RF PIN Mode PIN Only Mod
11. Wm 0818 Memory 0818 Memory 2KByte EEPROM 512 Users U vacent IPK50 Up to 2 inches bcm Read Passive Type vel ROM IPC170 IPC180 Range Up to 4 inches 10cm Up to 4 inches 10cm Power Current DC 12V Max 200mA 9 ports Exit Button Door Contact Aux 1 Aux 2 Aux 3 2 ports Form C Relay Output COM NO NC DC12 18V Rating Max 2A 1 port port Chime Bell Output DC5V Rating Max 500mA Bell port Chime Bell Output DC5V Rating Max 500mA Rating Max 500mA 1 port TTL Output 1 TTL Output DC5V Rating Max20mA Rating Max fpor TTLOutput DCSV Rating Max20mA 35 to 65 C 31 to 149 F 10 to 90 relative humidity non condensing Dark Pearl Gray Polycarbonate 87mm x 100mm x 31mm 3 4 x 3 94 x 1 22 210g 0 46lbs Certification UL FCC CE MIC 9 Front Panel Description Main Unit of Star 100R iPASS 100R Output Port Star 100R LED Display ET pan 9 Marian E ID TELE Star 100R tess IP100R 6 Identifying Supplied Parts Please unpack and check the contents of the box Star 100R nas o ia Star 100R 0 fesse IPTOOR o 99 O Main Unit Wall Mount O Ring User s Manual 1ea 1ea bea 1copy Ill mi 3 5 40 Screw 3 5 12 Screw Anchor Bolt 4ea 4ea 4ea T Installation 7 1 Tear off page 38 and use the provided template to drill two 6 32 holes and one 1 2 hole on the proper location of the wall t
12. is not recognized 505 S Alarm RELAY activates for 2sec Red LED lights on for 2sec gt B 02 S 3 Duress Password 00 Duress Alarm to TTL output port for 03 sec 4 QUICK ACCESS MODE Disable 5 Chime Bell output Enable Chime Bell activation time 05 sec 6 Melody sound Enable 7 Keypad lock out time when Try Out error detected 7 01 min 8 Detect all inputs from H to L 9 10 11 1 When User Access Card or PIN is granted Door RELAY activates for 3sec Green LED lights on for 3sec 9 Activate TTL output to L 10 Delay time to activate SECURE MODE 00 min 11 Door Open time out for Door Contact sensor 00 sec 12 Number of times of Try out 05 times 13 Input keypress time out time 20 sec 14 Tamper Alarm Disable Tamper Alarm output port 02 Alarm Relay 15 Toggle Mode Disable 16 Unlock followed by Door Contact Disable 13 Star 100R ipass IP100R 11 Operation 11 1 Normal Operation Mode Safe Mode When the Main Unit operates in normal mode the yellow LED is flashing every second 11 2 Open the Door When a registered Card or PIN is read the Door will open for 3 seconds along with the do mi sol do melody A GIEILOS S Registered Card or PIN 11 3 Exit Open the Door e To request for exit from the inside an Exit Button can be used to open the lt aN door for the same duration as in 11 2 E3
13. necessary use mild soap Do not use this product near water such as bath tub wash bowl kitchen sink laundry tub in a wet basement or swimming pool This product should be operated only from the type of power source indicated on the marking label If you are not sure of the type of power supplied to your installation site consult your dealer or local power company Never push objects of any kind into this product or through the cabinet slots as they may touch voltage points or short out parts that could result in fire or electric shock Never spill liquid of any kind on the product To reduce the risk of electric shock do not disassemble this product by yourself but take it to qualified service whenever service or repair is required Opening or removing the covers may expose you to dangerous voltages or other risks Also incorrect reassembly can cause electric shock when the unit is subsequently used Unplug this product from the Direct Current DC power source and refer to qualified service personnel under these conditions a When the power supply cord or plug is damaged or frayed b If liquid has been spilled on the product c If the product does not operate normally after following the operating instructions in this manual Adjust only those controls that are covered by the operating instructions in this manual Improper adjustment of other controls that are not covered by this manual may damage the uni
14. not been evaluated by UL Connect the input wire of Auto Dialer to TTL output Orange White banded wire Connect wire of Auto Dialer to DC 12V be sure that the existing power supply has enough capacity to support this accessory or upgrade to a sufficient one Connect wire of Auto Dialer to Power GND wire Connect Telephone Line plug RJ 14 to Auto Dialer If an active High Auto Dialer is used then see section 12 71 to change the TTL output level from the defaulted setting 9 8 Wiegand Input Connection From Another Compatible Wiegand Reader Separate purchase required Connect wire of Reader to DC 12V be sure that the existing power supply has enough capacity to support this accessory or upgrade to a sufficient one Connect wire of Reader to Power GND wire Connect Wiegand output DATAO wire of the additional Reader to DATAO Pink wire Connect Wiegand output DATA1 wire of the additional Reader to DATA Cyan wire 9 9 RS 232 Communication Port Connection 9 pin connector COM Port female is required to connect serial communication RS 232 between Main Unit and Personal Computer Connect RS 232 TX Grey wire of Main Unit to pin number 2 of 9 pin connector 10 Star 100R ipass IP100R Connect RS 232 RX Blue wire of Main Unit to pin number 3 of 9 pin connector Connect RS 232 GND Yellow wire of Main Unit to pin number 5 of 9 pin connector Plug in 9 pin connector to COM1 or COM2
15. service center System Initialization See page 24 of this manual M MED 28 Star 100R TEENS ipass IP100R e Problem User card or PIN cannot be deleted e Cause gt An error in using a product or in system settings gt System malfunction data damaged or lost due to an external noise or a short circuit e Solution gt Make sure that installation and operation are normal s When the product operates normally Having a master card or PIN 1 Having a user card that wish to delete a Enter the master card or PIN 4 to 6digit mode 03 or 05 ENT b Enter mode 14 ENT to delete user access cards c Enter a user card to delete If there have enough user cards that wish to delete enter them in order continuously d Enter the master card or PIN 4 to 6digit mode 03 or 05 ENT Loosing a user card that wish to delete But knowing PIN of user card a Enter the master card or PIN 4 to 6digit mode 03 or 05 ENT b Enter mode 73 ENT to Enable Keypad Input To Enter ID Number c Enter the master card or PIN 4 to 6digit mode 03 or 05 ENT d Enter 4 ENT to delete user access cards e Enter PIN ENT If there have enough user cards that wish to delete enter them in order continuously f Enter the master card or PIN 4 to 6digit mode 03 or 05 ENT NO Caution See Setting Changes to delete master or user Loosing a master card or PIN 1 When loosing a master card thi
16. ARNING You may lose all setup data after execute Initialize 13 1 Hardware Initialization When the master card or ID is lost 1 Open the top case taking out four bolts on the back 2 As the left picture make two jumpers short in state of being on power 3 3 color LED blinking with beep sound indicates success of initialization 13 2 Wire Initialization When the master card or ID is lost 100R Over V5 0 0 IP100R Over V2 0 0 1 Main power off 2 Connect the orange and orange with white stripe wire together and power on 3 3 color LED blinking with beep sound indicates the success of initialization 100R Over V5 0 4 IP100R Over V2 0 2 4 Disconnect those two wires and wire them as shown above normal connection diagram 100R V5 0 0 V5 0 3 IP100R V2 0 0 1 4 Main power off again 5 Disconnect orange wire and orange with white stripe wire as shown above normal connection diagram and power on 25 Star 100R ieass P100R 14 FCC Registration Information FCC REQUIREMENTS PART 15 Caution Any changes or modifications in construction of this device which are not expressly approved by the manufacturer for compliance could void the user s authority to operate the equipment NOTE This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interface and 2 This device must accept any interference received inc
17. Detection from L to H AUX 1 input is detected on the raising edge of AUX 1 input Configuration Card Configuration PIN 6 1 Ey 12 62 Set AUX Input 1 Detection from H to L AUX 1 input is detected on the falling edge of AUX 1 input Defaulted setting Configuration Card IConfiquration PIN 6 2 JEn 12 63 Set AUX22 Input Detection from L to H AUX 2 input is detected on the raising edge of AUX 2 input Configuration Card IConfiguration PIN 6 3 Ey 12 64 Set AUX 2 Input Detection from H to L AUX 2 input is detected on the falling edge of AUX 2 input Defaulted setting Configuration Card Configuration PIN 6 4 Je 12 65 Set AUX 3 Input Detection from L to H AUX 3 input is detected on the raising edge of AUX 3 input Configuration Card Configuration PIN 6 J 5 12 66 Set AUX 3 Input Detection from H to L AUX 3 input is detected on the falling edge of AUX 3 input Defaulted setting Configuration Card IConfiguration PIN 6 6 Jenn 12 67 Set Exit Button Input Detection from L to H Exit Button input is detected on the raising edge of Exit Button input Configuration Card IConfiguration PIN 6 7 Jen 12 68 Set Exit Button Input Detection from H to L Exit Button input is detected on the falling edge of Exit Button input Defaulted setting Configuration Card IConfiguration PIN 6 8 Jenn 22 Star 100R IDTECX aPAss P100R 12 69 Set Doo
18. Enable QUICK ACCESS MODE Disable QUICK ACCESS MODE Enable Toggle Mode for Lock control Disable Toggle Mode for Lock control Enable Unlock followed by Door Contact Disable Unlock followed by Door Contact Disable Melody sound turning off both the melody amp keypress audio feedback Enable Melody sound Change keypad lock out time when Try Out error detected oet Aux Input 1 Detection from L to H oet Aux Input 1 Detection from H to L oet Aux Input 2 Detection from L to H oet Aux Input 2 Detection from H to L oet Aux Input 3 Detection from L to H oet Aux Input 3 Detection from H to L oet Exit Button Input Detection from L to H oet Exit Button Input Detection from H to L oet Door Contact sensor Input Detection from L to H oet Door Contact sensor Input Detection from H to L Activate TTL output to H Activate TTL output to L Enable Keypad Input To Enter ID Number Disable Keypad Input To Enter ID Number Enable Chime Bell Output Disable Chime Bell Output Set delay time to activate SECURE MODE set Door Open time out for Door Contact sensor oet number of times of Try Out Set input key press time out time oet Tamper Alarm output port Enable Tamper Alarm Disable Tamper Alarm Re Initialize and erase all setup data 16 Star 100R 5 4 55 1 IP100R 12 11 Add User Access Cards RF CARD ONLY MODE 3 a Configuration
19. PIN 4 to 6digit mode 03 or 05 ENT Enter 82 ENT to Set Number of Times of Try Out Enter 2 digit of Try Out Times ENT e g 10 ENT 10 Set number of try out times when unregistered ID Caution See Setting Changes to Set Number of Try Out c Change Keypad Lock out Time When Try Out Error Detected is below Enter the master card or PIN 4 to 6digit mode 03 or 05 ENT Enter 60 ENT to Change Enter 2 digit of Try Out Times ENT e g 10 ENT 10 Interrupt entering a keypad for 10 min 2 Although it goes on definite time buzzer doesn t go off continuously Initialize the product Caution Upon initialization all data default value will be restored e f the problem still persists contact our customer service center External Device e Problem An exit button will not work e Cause gt An error in connection between the exit button and the 100R gt An exit button error gt Internal circuit element damaged or malfunctioning e Solution gt Make sure of connection between the exit button and the 100R and of operation of exit button zs Check the connection between the exit button and the 100R System Initialization See page 24 of this Manual E Initial Setting See page 10 of this Manual 32 Star 100R ipass IP100R DC 12V Power Supply Yellow Red Stripe Connecting an Exit Button Caution Make sure to use a NO Nor
20. User s Manual Star 100R 55 1 P100R Star 100R Star 100R IDTECK iPAss P100R Table of Contents 1 Important Safety 7 7 3 Ds GE MCN ell T E 4 scm TER 4 T SDEC ICAU OM siririca aeniea Fed rini i a d eiu E RE UN C SIN TEE FTN 5 5 Front Panel Descrip N usas re Dn ac Cu eio a Ee vu o 5 6 Identifying Supplied Parts cin orsi 6 7 Cru e X 6 8 Wiring Color Tabl 5 4 7 9 System Wiring for Typical Application 9 HUNTER T 11 OT OS AU ON PRETERITO 14 12 Set ng CMAN GOS iiinn aaa a aaan Eta aaae aia 15 13 25 14 FCC Registration Information erre 26 15 IrOUDIGSTIOOHIO coi iiec HER CEYEE iaaa 27 16 Warranty Policy and Limitation of Liability 37 TEs VO MMPI ALC RR 39 IDTECK Star 100R ipass IP100R 1 Important Safety Instructions When using your Star 100R iPASS IP100R basic safety precautions should always be followed to reduce the risk of fire electrical shock and injury to persons In addition the following should also be followed Oo N C1 O gt Read and understand all instructions Follow all warnings and instructions marked on the product Do not use liquid cleaners or aerosol cleaners Use a damp cloth for cleaning If
21. alize the 100R using the wires You can use those functions again by setting JP9 and JP10 back to the default state wm mum mam mant 000 0 ud ad m Star 100R IDTECK 1 55 IP100R 9 System Wiring for Typical Application Star 100R EXIT EXIT gt lt BUTTON CONTACT CONTACT AUX IN CHIME GND d GND ALARM RELAY COM PIR SENSOR DOOR RELAY ALARM RELAY NO CHIME BELL 12V DC 12V POWER SUPPLY 9 1 Power Connection Connect wire of DC 12 power to Red wire and Red White banded wire Connect Power GND wire of DC 12V to Black wire and Black White banded wire 9 2 Door Lock Connection 9 2 1 Connection of POWER FAIL SAFE Door Lock Connect Door RELAY NC Blue White banded wire to DC 12V be sure that the existing power supply has enough capacity to support this accessory or upgrade to a sufficient one Connect wire of Door Lock to Door RELAY COM Grey Red banded wire Connect wire of Door Lock to Power GND wire 9 2 2 Connection of POWER FAIL SECURE Door Lock Connect Door RELAY COM Grey Red banded wire to DC 12V be sure that the existing power supply has enough capacity to support this accessory or upgrade to a sufficient one Connect wire of Door Lock to Door RELAY NO White Red banded wire Connect wire of Door Lock to Power GND wire 9 3 Alarm Device Connection C
22. ard or PIN gt System malfunction data damaged or lost due to an external noise or a short circuit gt Internal circuit element damaged or malfunctioning e Solution gt Make sure that installation and operation are normal When installing the 100R first or When finishing system initialization Because system is the status of initialization register mode selection master card or PIN and user 1 100R Mode Selection Mode Number ENT RF Only 01 ENT RF P W 02 ENT PIN Only 03 ENT RF or PIN 05 ENT 2 Enter the master card or PIN 4 to 6digit mode 03 or 05 ENT 3 By modes enter the master card PIN and password 4 Enter the master card or PIN 4 to 6digit mode 03 or 05 ENT Caution See Initial Setting to register master or user s When problem occurs while 100R operates normally It is caused by system malfunctions 1 Turn on the 100R when it s off OFF gt ON e f this does not solve the problem initialize the product Caution Upon initialization all data default value will be restored e f the problem still persists contact our customer service center System Initialization See page 24 of this manual 27 Star 100R iuda iPass P100R e Problem The 100R operates suddenly on general mode during setting or registering a user on mode selection e Cause gt Over standby time on mode selection e Solution gt If not entering a key or a card within 20 sec on mode s
23. arity bit Data bit Stop bit Make sure of connecting communication cables 1 Make sure that connecting communication cables between the 100R and the PC 2 Make sure of cable s maximum distance 45232 Max 15m The max transmission range for each communication type is greatly affected Caution by the communication environment Eliminate any electrical noise around the communication cable or disconnect it from other cables e f the problem still persists contact our customer service center Keypad e Problem An RF card works properly but the 100R will not recognize the RF card number when it is entered in the keypad e Cause gt An error in system settings gt Connection malfunction of communication cable gt System malfunction data damaged or lost due to an external noise or a short circuit 31 Star 100R ipass IP100R e Solution gt Check if any buzzer goes off when the keypad is pressed f the buzzer goes off 1 Enter the master card or PIN 4 to 6digit mode 03 or 05 ENT 2 Enter 73 ENT to Enable Keypad Input To Enter ID Number eM see Setting Changes to Enable Disable Keypad Input To Enter ID Number f the buzzer does not go off 1 After going on definite time buzzer makes a sound again a If entering unregistered ID 5 times continuously entering a keypad is interrupted for 1 min b Set Number of Times of Try Out is below Enter the master card or
24. ct all right again on wall 100R V5 0 0 over or IP100R V2 0 0 over 1 After power is off separate product from wall 2 Connect orange wire to orange with white stripe wire 3 After power is on make sure of system initialization At this time bell grows in sound and LEDs blink 4 After slicing two short wires off the product make off the power 9 Use it installing the product all right again SHE See System Initialization to register master or user iin System Initialization See page 24 of this Manual 30 Star 100R ipass IP100R Make sure to consult a technician before separating or initializing IDTECK Caution a product e f the problem still persists contact our customer service center Communication e Problem Although the 100R connects with PC communication was not at all e Cause gt Setup malfunction of communication environment gt Connection malfunction of communication cable gt System malfunction data damaged or lost due to an external noise or a short circuit e Solution gt Make sure that communication environment is set and cables are connected Make sure of set up between controller and PC 1 Make sure that each COM Port is same COM Port is connected with PC and its settings should be identically set on application software 2 Baud rate is fixed by 9600bps Make sure that communication environment of application software is set up as shown below Item P
25. e or Configuration Card Command Code Configuration PIN Command Code Summary Table of Commands Command Action Change setting values 11 Add User Access Cards RF CARD ONLY MODE 12 Add User Access Cards and PIN RF CARD PIN MODE 13 Add User Access PIN numbers PIN ONLY MODE 14 Delete User Access Cards or PIN 15 Add User Access Card PIN RF PIN Combination Mode 21 Change Door open time when User Access Card or PIN is granted 22 Change Alarm time when User Access Card or PIN is denied 23 Change Alarm time when Try Out error detected 24 Change Alarm time when Door Contact error detected 25 Change Alarm time when Aux Input 1 detected 26 Change Alarm time when Aux Input 2 detected 21 Change Alarm time when Aux Input 3 detected 28 Change Alarm time when magnet detected 29 Register 2 digits Duress Alarm password 30 Change Alarm time when Duress Alarm detected 31 Test Door open time set by command 21 32 Test Alarm time set by command 22 33 Test Alarm time set by command 23 34 Test Alarm time set by command 24 35 Test Alarm time set by command 25 15 IDTECK 36 37 39 41 42 43 44 45 46 47 48 51 52 60 62 63 64 65 66 67 68 69 10 71 T2 13 74 T1 18 80 81 82 83 84 88 89 99 Star 100R tPAss P100R Test Alarm time set by command 26 Test Alarm time set by command 27 Change Chime Bell activating time Open door unconditionally Close door unconditionally
26. e stripe Aux In 3 Brown 45232 TX Gray RS232 RX Blue RS232 GND Yellow Please cut out tail connector before installation Star 100R 5 4 55 1 P100R OPTIONAL Wiegand Output Function Applicable to v5 2 0 of the 100R v2 2 0 of the IP100R You can configure the 100R to generate output in Wiegand format and use it like a reader The 100R can output data from card reading but doesn t output data from keypad input JP10 JP9 JP10 9 JP10 JP9 Lo o EN aM DEFAULT WIEGAND TTL Output Chime Bell Quiput 9gand Output v JP9 JP10 Short PIN1 and PIN2 gt Wiegand Output v JP9 JP10 Short PIN2 and PINS lt Default TTL Output Chime Bell Output In order to configure the 100R to output in Wiegand format you need to set the jumpers as shown above Changes when Wiegand Output Mode is applied Output Orange wire with White stripe gt Wiegand Data0 Output Chime Bell Output Brown wire with White stripe Wiegand Data1 Output EEUU M ML a a a a a a a am mm a 2 ma Xm LUS mm mm mm a a a ma M S mm a am a a a mm mm a a a LU When the Wiegand Output function is used TTL Output wire and Chime Bell Output wire are changed to Wiegand Data 0 Output wire and Wiegand Data 1 Output wire and therefore you can t use those functions In addition because TTL Output wire is changed to Wiegand Data 0 Output you can t initi
27. efer to Table 1 for OM tt 00 99 sec 2 569 00I DOM HH 2 7 VENT Configuration Card Command Output Mode Door time Alarm Time TTL time Configuration PIN 12 28 Change Alarm Time When Magnet Detected Refer to Table 1 for OM tt 00 99 sec ong O Configuration Card Command Output Mode Door time Alarm Time TTL time Configuration PIN 12 29 Reaister 2 Digit Duress Alarm Password PWz00 99 Defaulted PWz 00 Do not use ases wes Configuration Card Command Password Configuration PIN Note 00 is registered as defaulted Password 19 Star 100R IDTECK 55 1 12 30 Change Alarm Time When Duress Alarm Detected tt 00 99 sec Defaulted TTL time 03 sec Gees Hm Configuration Card Command TTL time Configuration PIN 12 31 Test Door Open Time Set By Command 21 12 32 Test Alarm Time Set By Command 22 12 33 Test Alarm Time Set By Command 23 12 34 Test Alarm Time Set By Command 24 12 35 Test Alarm Time Set By Command 25 12 36 Test Alarm Time Set By Command 26 12 37 Test Alarm Time Set By Command 27 Outputs set by command will be tested Configuration Card Command Configuration PIN 12 39 Change Chime Bell Activating Time tt 00 99 sec Defaulted Chime Bell time 05 sec 3 0 ENT ENT Configuration Card Command Chime Bell time Configuration PIN 12 41 Open Door Unconditional Configuration Card Configuration PIN 4 2 Jenn 12 42
28. election the product operates on general mode automatically Registering or Deletion e Problem User Card or PIN cannot be registered additionally e Cause gt An error in using a product or in system settings gt Over permissible register person e Solution gt Make sure that installation and operation are normal s When installing the 100R first or When finishing system initialization Because system is the status of initialization register mode selection master card or PIN and user 1 100R Mode Selection Mode Number ENT RF Only 01 ENT RF P W 02 ENT PIN Only 03 ENT RF or PIN 05 ENT 2 Enter the master card or PIN 4 to 6digit mode 03 or 05 ENT 3 By modes enter the master card PIN and password 4 Enter the master card or PIN 4 to 6digit mode 03 or 05 ENT See Initial Setting to register master or user When registering a user card additionally while using a product Register a user card only because master card is registered 1 Enter the master card or PIN 4 to 6digit mode 03 or 05 ENT 2 By modes enter Mode Number ENT to add user access cards RF Only 11 ENT RF P W 12 ENT PIN Only 13 ENT RF or PIN 15 ENT 3 By modes enter a user card PIN and password 4 Enter the master card or PIN 4 to 6digit mode 03 or 05 ENT Caution See Initial Setting to register master or user e f the problem still persists contact our customer
29. figurable interfaced behaviors many of the Star 100R iPASS IP100R internal behaviors are programmable as well The internal operating parameters include the number of incorrect access attempts before alarm condition is triggered tampering protection from mounting removal and timers Furthermore every event or transaction can be captured and time stamped by the Star 100R iPASS IP100R application software via the provided RS 232 wires 3 Features 125KHz Standalone Proximity PIN Single Door Access Controller 100R PSK modulation IP100R ASK EM Format Basic Time amp Attendance Function 512 Users including One Master Card 1 External Reader Port for Exit 26bit Wiegand Standalone Network Communication via RS232 All I Os and Operation Time Programmable by Keypad Independent 5 Inputs and 4 Outputs Including 2 Form C Relay Outputs Keypad Lock by Try out Error Alarm Function Duress Mode Function Toggle Mode for Door Opening Closing Lock Control by Door Contact Switch Safe Default Secure Mode Available Dual Tamper Switches Chime Bell Output Mode Selection RF Only PIN 4 6 digit Only RF P W 4 digit RF or PIN Options 4ch Voice Auto dialer Compatible Software STAR 100R PRO Comparison Table 10R 125KHz PSK modulation IP100R 125KHz ASK EM Format Star 100R IDTECK 1 55 IP100R 4 Specification MM ME IP100R Dual 8bit Microprocessor B
30. ime out for Door Contact Sensor tt 00 99 sec Defaulted value 00 sec means no detect Door Contact Sensor refer to 12 24 for Alarm time settings ENT ENT Command Door Open time out Configuration PIN 12 82 Set Number of Times of Try Out NN 00 99 times Defaulted Try out numbers 05 times Configuration Card Command Try out numbers Configuration PIN 12 83 Set Input Keypress Time out Time tt 10 99 sec Defaulted Keypress time out 20 sec Minimum tt 10 sec Configuration Card Command Keypress time out time Configuration PIN 12 84 Set Tamper Alarm Output Port Refer to Table 1 for OM Defaulted Output port 02 Alarm Relay s 4 ey oJen Command Alarm Output Port Configuration PIN 12 88 Enable Tamper Alarm To comply with UL 294 the Standard for Access Control System Units the Tamper Alarm must be enabled Configuration Card IConfiqu ration PIN 12 89 Disable Tamper Alarm Configuration Card Configuration PIN Do Defaulted setting 12 99 Re Initialize and Erase All Setup Data Please use this command when you really want to erase all data and start the unit from the beginnin onfiguration Car Configuration PIN 9 9 Jena 24 Star 100R IDTECK 55 1 P100R 13 Initialization When you lost the Configuration Card or forgot the Master PIN number you may need to re initialize the unit for new setup There is a hard wired Initialize function on the unit x W
31. kmanship for the period specified in the table below from the date of purchase under normal customer use This Warranty doesn t apply 1 to any product which has been dismantled without authorization of IDTECK or and has a damaged or detached QC label on its back side 2 to any losses defects or damages caused by improper testing operation installation maintenance modification alteration or adjustment 3 to any product with a damaged or faded serial number on it or 4 to any losses defects or damages caused by lightning or other electrical discharge natural disaster misuse accident or neglect This Limited Warranty is in lieu of all other warranties obligations or liabilities on the part of IDTECK and IDTECK DISCLAIMS ANY AND ALL WARRANTY WHETHER EXPRESS OR IMPLIED OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE IDTECK does not and cannot know who is present what property is located where this product will be used it would be extremely difficult to determine the actual damages that may result from a failure of the product to perform as anticipated and the low price of this product is based upon the nature of the product provided and the limited liability that IDTECK assumes IDTECK IS NOT RESPONSIBLE FOR ANY PERSONAL INJURY PROPERTY DAMAGE OR LOSS DIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES OR OTHER LOSS AND IDTECK S MAXIMUM LIABILITY SHALL NOT IN ANY CASE EXCEED THE PURCHASE PRICE OF THE PRODUCT To obtain
32. luding interference that may cause undesired operation This equipment has been tested and found to comply with the limits for a Class A Digital Device pursuant to Part 15 of the FCC Rules These limits are designed to this equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the radio or television off and on the user is encouraged to try to correct interference by one or more of the following measures 1 Reorient or relocate the receiving antenna 2 Increase the separation between the equipment and receiver 3 Connect the equipment into an outlet on another circuit 4 Consult the dealer or an experienced radio TV technician for help 26 Star 100R IDTECK 55 1 15 Troubleshooting If a problem occurs during the use of this product do not attempt to disassemble the product by yourself Please check the following suggestions If your problem still persists contact our customer service center Operation e Problem When power is first supplied 3 LEDs of 100R blinks only and an RF card doesn t recognize e Cause gt System initialization Status Unregistered Master C
33. mal Open type exit button Check the exit button operation 1 Check the condition of the connection cable a short circuit or cut between and the 100R 2 Connect two wires from the exit button If the FACE007 operates when the exit button is pressed Replace the exit button If the FACE007 does not respond Initialize the product Caution Upon initialization all data default value will be restored Caution See Installation to connect the exit button e f the problem still persists contact our customer service center e Problem Your RF card is successfully recognized by an exit reader but the RF card data is not transferred to a computer or other data is transferred e Cause gt A connectivity error between the exit reader and the 100R gt Acommunication error between the exit reader and the 100R gt An exit reader error gt System malfunction data damaged or lost due to an external noise or a short circuit System Initialization See page 24 of this manual Initial Setting See page 10 of this manual Setting Changes See page 14 of this manual 79 Installation See page 6 of this manual 33 IDTECK star TUR iPASS P100R e Solution gt Make sure of connection between the exit button and the 100R and of operation of exit reader zs Check the connection between the exit button and the 100R Black f PANI Qi 31 B 100V 220V Power Supply DC
34. o mount the Wall Mount bracket as shown below If the gang box is alreadv installed on the wall then skip this step 6 32 hole 1 55 39 5mm 1 85 47mm 3 pE wi T e E m 2 05 52mm 1 52 385mm 1 52 38 5mm 3 03 77mm Star 100R teases IPTOOR 7 2 Using 2 screws install wall mount to the wall CAUTIONS Before mounting the STAR 100R unit to the Wall Mount bracket operational testing of the unit should be completed as the locking pins will lock the unit to the Wall Mount Removing the unit from the Wall Mount bracket after they have been installed together may cause damages to the bracket and render its effectiveness 7 3 Insert 5 O rings to the wall mount as indicated then route the cable of the main unit through the center hole and push the main unit to wall mount to lock the main unit and make sure that the main unit is locked with wall mount 8 Wiring Color Table SIGNAL COLOR Main Power 12V Power Ground GND Door Relay Out COM Gray with Red stripe Door Relay Out NC Blue with White stripe Door Relay Out NO White with Red stripe Alarm Relay Out COM White Alarm Relay Out NC Purple with White stripe Alarm Relay Out NO Purple TTL Out Orange with White stripe Chime Bell Out Brown with White stripe Wiegand Data 0 In Pink Wiegand Data 1 In Cyan Exit Button In Yellow with Red stripe Door Contact In Green Aux In 1 Orange Aux In 2 Green with Whit
35. onnect Alarm RELAY COM White wire to DC 12V be sure that the existing power supply has enough capacity to support this accessory or upgrade to a sufficient one Connect wire of Alarm Device to Alarm RELAY NO Purple wire Connect wire of Alarm Device to Power GND wire 9 Star 100R ipass IP100R 9 4 Exit Button Connection Connect one of the wires of Exit Button to Exit Button Input Yellow Red banded wire Connect the other wire of Exit Button to Power GND wire If a normally closed Exit button is used then see section 12 67 to change the detection scheme from the defaulted setting 9 5 Door Contact Sensor Connection Connect Door Contact sensor COM wire to Door Contact Input Green wire Connect Door Contact sensor NO wire to Power GND wire If a normally closed Door Contact sensor is used then see section 12 69 to change the detection scheme from the defaulted setting 9 6 Auxiliary Input Device Connection Applied to AUX Input 1 2 3 Connect one wire of the Auxiliary Input Device to the AUX Input wire Input 1 Orange Input 2 Green White banded Input 3 Brown wire Connect the other wire of Auxiliary Input Device to Power GND wire If a normally closed input device is used then see section 12 61 63 amp 65 to change the detection schemes from the defaulted settings 9 7 Auto Dialer Connection Separate purchase required The Auto dialer function of this unit has
36. r Contact Sensor Input Detection from L to H Door Contact input is detected on the raising edge of Door Contact input Configuration Card IConfiguration PIN 6 JC 9 Jen 12 70 Set Door Contact Sensor Input Detection from H to L Door Contact input is detected on the falling edge of Door Contact input Defaulted setting Configuration Card Configuration PIN 7 0 12 71 Activate TTL Output to H TTL output changes the state from logic 0 to logic 1 when it activates Configuration Card IConfiguration PIN 12 72 Activate TTL Output to L TTL output changes the state from logic 1 to logic 0 when it activates Defaulted setting Configuration Card Configuration PIN 12 73 Enable Keypad Input To Enter ID Number Keypad input is enabled to enter the ID numbers through keypads Configuration Card Configuration PIN 12 74 Disable Keypad Input To Enter ID Number Keypad input is disabled to enter the ID numbers through keypads Defaulted setting Configuration Card IConfiguration PIN Buc 12 77 Enable Chime Bell Output Configuration Card IConfiguration PIN Defaulted setting Enable 12 78 Disable Chime Bell Output Configuration Card Configuration PIN 12 80 Set Delay Time to Activate SECURE MODE F mmz00 99 min Defaulted Delay timez 00 min d ns am T hy m ooe Command Delay time IConfiguration PIN 23 Star 100R IDTECK 1 55 IP100R 12 81 Set Door Open T
37. repair or replacement under the terms of this warranty visit IDTECK s Website http www idteck com and place an online RMA request After an RMA code is issued return the product along with the authorization RMA code Warranty Period Warranty Period Warranty Period 1 RF CARD Active type 1 year 2 RF READER FINGERPRINT READER 3 STANDALONE CONTROLLER 4 CONTROL PANEL 5 FINGERPRINT CONTROLLER Product Category 3 years MOLDED RF READER 6 RF10 RF20 RF30 RF TINY IP10 IP20 IP30 SR10E SR10UE SR10SE SR10RWE SR10BE Lifetime RF CARD Passive type 7 IDC80 IDC170 IDK50 IMC125 LXK50 IPC80 IPC170 IPK50 ISC80 50805 0 IMC135 IHC80 IP100 IP200 37 Star 100R ipass IP100R RMA REQUEST FORM IDTECK accepts only on line RMA requests on our Website www idteck com Please provide us with basic information in the below form so that we can understand your problems better send us back this form with your products after an RMA code is issued on our Website This form is not compulsory RMA Authorization Code 1 Company Name 2 Model Name 3 Serial No 4 Original Invoice No 9 Distributor 6 Purchasing Date 7 RMA Request Date Please check your problems o Card Reading o Power o Keypad o Communication o Relay o LCD LED 8 Buzzer o Registration o Others IDTECK RMA Center lt lt 3F 10 10 1 10 2 Dodang Dong Weonmi Gu Bucheon Si Gyeonggi Do 157 030
38. s cannot register delete a user and use setting changes 2 Initialize the product Caution See Initial Setting to register master or user Caution Upon initialization all data default value will be restored e f the problem still persists contact our customer service center System Initialization System Initialization See page 24 of this manual E Initial Setting See page 10 of this manual 29 IDTECK Star l00R iPAss P100R e Problem Registering deleting a card and setting change cannot be used because of loosing a master card or PIN e Cause gt A user carelessness e Solution gt When loosing a master card or PIN if you change product s settings you should initialize the product n system initialization master user and system settings are changed by initials s System Initialization by product s versions 100R V5 0 0 under or IP100R V2 0 0 under 1 After power is off separate product from wall 2 Separate enclosure slicing four screws off the rear of product yy dN 4 3 Turn on product as step 2 stands For initializing connect jumper switches which are located by LEDs bottom of PCB a 1 n z j Ek R p ij T EHH FEL d 2 2 4 Make sure of system initialization At this time 3 LEDs should be blinked simultaneously 5 After power is off assemble the rear of product fixing four screws Finishing assembly fix the produ
39. t and will often require extensive work by a qualified technician to restore normal operation d If the product exhibits a distinct change in performance Star 100R teases P100R 2 General A properly configured Star 100R iPASS IP100R is an intelligent PIN amp Proximity and PINPAD Single Door Controller that combines the convenience of wireless entry with the security of an alarm system Also the Star 100R iPASS IP100R system will give you field proven reliability and cost effective solution anywhere access controls and high security are required Each standard unit can store up to 512 users or card IDs The task of assigning cards and managing a user s database is so simple user friendly and can be accomplished in many ways it could be as simple as presenting each card to the unit or as descriptive as a user s database with an easy to use Graphical User Interface The Star 100R iPASS IP100R can interface and operate with these accessories Request for EXIT button Door Contact sensor PIR sensor Fire sensor and other sensors via 5 independent input ports Also output ports which include 2 Relays and 2 TTL outputs can be used to control the operation of other accessories such as Electric Magnetic Door Lock Alarm Chime Bell and Auto Dialer Moreover the status or behaviors of these input and output accessories are configurable to provide the system administrator with complete customized control of the system Besides the above con
Download Pdf Manuals
Related Search
Related Contents
Loewe Wireless Speaker User's Manual Servolor 2 Nuevo Aroma - Distribuciones Zaragoza, SA Segurança em Laboratório Químico - Instituto de Química Baureihe 1402-01 - Sander Fördertechnik ACT720_Operating Manual MANUEL D`UTILISATION ET D`ENTRETIEN Saris The T-Rax Sport 4 bike User's Manual Xerox Phaser 7800 Repacking Instructions Poséo 5200 User Manual - Support Technique AURES Emerson MR98 Drawings & Schematics Copyright © All rights reserved.