1. Li th a i a igl eed USER MANUAL Please read this manual thoroughly before use Retain this manual for future reference Taikan Optical Receiver Owner s Manual This manual is intended for use by purchasers of Taikan s Optical Receiver and their qualified technicians This document is the property of Taikan Company Inc Taikan and embodies proprietary subject matter All design manufacture reproduction use and sale rights regarding these products are expressly reserved This manual may not be reproduced without written consent from Taikan All copyright patent and trade secrets for this manual and product are expressly reserved by Taikan Specifications are also subject to change without notice SAFETY PRECAUTIONS gt Read the user manual carefully before proceeding with any part of the installation gt Installation and operation of the product must be performed only by qualified personnel and always in accordance with applicable electrical codes gt All warnings on the product and in the operating instructions should be adhered to gt Unplug the product from the power outlet before cleaning Do not use liquid or aerosol cleaners Use a damp cloth For the optical connector it is recommended that you use RIFOCS CO Ltd s 945 946 Optical Receiver units may emit harmful laser radiation gt Do not block or cover openings These are provided for ventilation and protection from overheating The
2. ad connector clean the SC APC ferrule on the optical jumper cable that will eventually connect to the receiver module This can be done using a commercial cleaning tape or isopropyl alcohol and lint free tissues Once the optical jumper cable s ferrule has been cleaned it is recommended that you measure the optical power using an optical power meter EA The RF output jacks on the receiver s rear panel are female There is a total of 4 ports and a corresponding 12dB test point Connect a test jumper from one of these ports to a signal level meter or spectrum analyzer Ensure that all unused RF outputs are terminated with a 75 ohm terminator 6 CONNECTING THE POWER CORD Attach the power cord to the outlet on the rear panel Upon powering the receiver the display will say Return Path Optical Receiver Applies to OR4L S unit only Taikan 919 E 29th St Lawrence KS 66046 tel 1 800 255 0247 fax 785 841 9512 email support taikan com www taikan com INDICATOR LIGHTS The 4 Port Optical Receiver is built with four indicator lights and a display screen to assist in identifying problems that may occur Upon successful set up all of the lights on the front panel will be green Applies to OR4L S unit only If the Red Indicator Light is on detach the fiber line for the Optical connector clean the port with an approved fiber cleaner and reattach the lines Please contact a Taikan representa
3. h receiver is designed to fit into a standard 19 rack and supports 4 optical receiver modules Supports four optical receiver modules LED status monitor indicators for each module RF test point provided on back panel Adjustable RF output level Adjustable attenuator located on front panel Power of 135 250 VAC e 5 200 MHz bandwidth e 1200 1600 nm wavelength Available with SC APC or FC APC connectors NOMINAL SPECIFICATIONS OPTICAL FEATURES Optical Wavelength 1200 1600 nm Optical Input Range 22 0dBm Optical Connector Type Std SC APC RF FEATURES Option FC APC RF Bandwidth 5 200 MHz Adjustable Output GENERAL FEATURES Level Attenuation 0 20 dB Power 135 250 VAC Connector Type Ftype Weight 3 kg 6 lb Dimension LxWxH 483 x 385 x 44 mm 19 x 15 x 1 75 in Taikan 919 E 29th St Lawrence KS 66046 tel 1 800 255 0247 fax 785 841 9512 email support taikan com www taikan com TTT Optical Receiver 07 SECTION TWO Il INSTALLATION UNPACKING Carefully open the package and adhere to all safety guidelines outlined in the safety section Check the packaging material for the following components gt OR4x S gt User Manual gt Power Cord MOUNTING Carefully slide the optical receiver inside a standard 19 headend rack Make sure that the rack is in a secure and clean environment Pa Before removing the dust cap from the receiver s SC APC bulkhe
4. is NOT allowed and may cause irreparable damage to product Taikan does not as sume any responsibility for these modifications Taikan 919 E 29th St Lawrence KS 66046 tel 1 800 255 0247 fax 785 841 9512 email support taikan com www taikan com SE rt eae Optical Receiver 03 TABLE OF CONTENTS Preface 01 Safety Precautions 03 Introduction 07 Product Summary Standard Features Nominal Specifications Installation 7778 Unpacking Mounting Optical Connections RF Connections Connecting the Power Cord Indicator Lights LCD Screen Menu Definition Adjusting IP Address Maintenance eS 10 Maintenance Return amp Warranty Policies NN Product Return Procedure Standard Taikan Product Warranty Taikan 919 E 29th St Lawrence KS 66046 tel 1 800 255 0247 fax 785 841 9512 email support taikan com www taikan com K o o E TTT 7 Optical Receiver 05 JO ONO N INTRODUCTION PRODUCT SUMMARY The OR4x S a 4 port optical receiver receives optically transmitted CATV signals This unit is primarily used in upgraded cable television and fiber distribution systems The OR4x S unit is available with an optional LCD screen ensuring ease of navigation through the menu system Optical power indicators and RF test ports on the front panel are conveniently accessible to monitor the receiver s operating status Eac
5. tive at support taikan com if the indicator light remains red o ME Toggle through the LCD screen by pushing the up and down arrows next to the screen The state button is equivalent to an enter button 8 3 MENU DEFINITION Menu 1 Serial Number displays the product serial number Menu 2 Input displays the input optical power in dBm Menu 3 Unit Temp displays the system temperature in C Menu 4 5V Reads displays the voltage 5V Menu 5 5V Reads displays the voltage 5V Menu 6 24V Reads displays the voltage 24V Menu 7 IP displays the IP address of SNMP Menu 8 Submask displays the address of the net mask Menu 9 Gateway displays the gateway address of SNMP Menu 10 Trap Addr 1 displays the TRAP1 address of SNMP Menu 11 Trap Addr 2 displays the TRAP2 address of SNMP ESISTESSE To change the IP address last digit IP 192 168 000 015 from a 5 to a 6 do the following 1 Use the status button to toggle to the place of the 5 2 Use the up down arrows to select the number you d like 3 Select status button Optical Receiver 09 gt SECTION THREE SECTION FOUR MAINTENANCE RETURN amp WARRANTY PRODUCT RETURN PROCEDURE MAINTENANCE If you need to return the product for repair please follow these steps Clean and vacuum the cooling fans periodically recomended monthly 1 Contact a Taikan Representative at support taikan com
6. to obtain a Return Authorization Number 2 When returning the product for repair include the following information Confirm that all of the power LED s are green E A EE E Name gt Model Number Check the cooling fans on a weekly basis to ensure that they are operating properly and are gt Serial Number unobstructed gt Reason for Return 3 Prior to repairing the device Taikan will inform you about the test results and or any additional repair charges that may apply Once we have received your confirmation we will proceed with the repair 4 The repair period will depend on the severity of the problem 5 After it is returned the product will still be under its original warranty The repair component s is under warranty for 90 days after you have received the repaired product see below STANDARD TAIKAN PRODUCT WARRANTY Taikan provides a limited three year Warranty Warranty to original purchaser on its product against manufacturing defect and workmanship under normal use and service During the War ranty period Taikan will repair or replace the product to correct defects in material and workman ship This Warranty shall not apply to a product which has been altered in any way so as to affect its stability or durability nor which has been subject to misuse or negligence This Warranty does not cover a product which has been damaged by severe weather conditions such as extreme wind ice storms lightning or other natural
7. weather conditions over which Taikan has no control Claimants under this Warranty shall present their claim along with the defective product to Taikan Non compliance with any part of this claim procedure may invalidate this Warranty in whole or part This Warranty is expressly in lieu of all other agreements and warranties expressed or implied Taikan does not authorize any person to assume for it the obligations contained in this warranty and neither assumes nor authorizes any representative or other person to assume for it any other liabilities in connection with the product delivered or provided In no event shall Taikan be liable for any loss of profits loss of use interruption of business or indirect consequential damages of any kind Taikan will not be liable for damages in any amount greater than the purchase price of the product Taikan 919 E 29th St Lawrence KS 66046 tel 1 800 255 0247 fax 785 841 9512 email support taikan com www taikan com C00 E ee Optical Receiver 11
8. when the product is powered on or when the case is opened maximum operating temperature is 50 C 122 F gt This product should be operated only from the type of power sources indicated on the marking label gt This product may be equipped with a polarized AC line plug a plug having one blade wider than the other or a different shape This plug will fit into the power outlet only one way This is a safety feature If you are unable to insert the plug into the outlet try reversing the plug Contact your electrician to replace the obsolete outlet if this still does not work Do not compromise the safety purpose of the polarized plug gt For added protection during a lightning storm or when the equipment is left unattended or unused for long periods unplug it from the power outlet and disconnect the cables between the equipment and the fiber subsystem These precautions will prevent damage to the equipment that could be caused by lightning strikes or power line surges gt Do not attempt to service this equipment yourself as opening or removing the cover may expose you to dangerous voltage or other hazards refer all servicing to Taikan A Taikan representative can be reached at support taikan com Please be cognizant of all safety guidelines and 9 P pport adhere to the recommendations listed If any parts need to be replaced notify a Taikan representative at support taikan com gt Unauthorized alteration or inappropiate repair