Home
        6 digits IV-11 VFD Clock with 2 Alarms
         Contents
1.    Thanks for your interest in my 6 digits  V 11 VFD Clock     I have tried to create stylish  reliable  accurate and easy to use Clock and I hope you will love it  and this Clock is what you are really expected to see when you was looking for something new     Please read carefully the information below as it will help you to use your Clock efficiently and  in proper way and hopefully will avoid any negative moments which could arise in case of  incorrect or careless use     Clock key features    Based on six Soviet IV 11 tubes from USSR time   Six 20mm high digits IV 11 Vacuum Fluorescent Display  VFD  Tube  Displays Time   Date and 2 Alarm clock sets   Time   Date display mode with auto switch in 10 seconds interval   Accurate time clock source from internal crystal    Integrated 2 Alarm Clocks   Easy control with only 2 buttons   Uses standard 12V wall plug Power Supply   Precision Seconds setup   Internal buzzer for Alarm1 and Alarm2   Auto preset and manual display brightness    The Clock functions in two main modes     Display Mode and Setup mode  Display mode   In the Display Mode Clock indicates the following information     Time in format HH MM SS    where HH is Hours  00 12 or 00 23   MM is Minutes  0 59   SS is Seconds  00 59     Alarm1 in format HH MM  1  where number 1 indicates Alarm1  Alarm2 in format HH MM  2  where 2 indicates Alarm2    Date in format   DD MM YY  LED dot separators    where DD is day  1 31   MM is Month 1 12   YY is Year  00 70     Time Date
2.  Ones will be flashing   Use Button2 to set correct value    Push Button  to choose next digit to set  Month Tens will be flashing   Use Button2 to set correct value    Push Button  to choose next digit to set  Day Ones will be flashing   Use Button2 to set correct value    Push Button  to choose next digit to set  Day Tens will be flashing   Use Button2 to set correct value     If some digits still don   t have the correct value  push Button  until this digit is highlighted again   Use Button2 to correct the value     To leave Setup Mode push and hold Button  until Digit stops flashing     Use the same technique to set Alarm1 or Alarm2     To go to the Alarm Setup Mode just choose the Alarm to display then push and hold Button1  until first Alarm digit starts to flash  You are in the alarm Setup Mode now   In this case only 4 digits can be set up and first digit is highlighted   Alarm Minutes Ones     In the Alarm Setup Mode  when digit is flashing  as soon as you change Alarm digit Value by  pressing Button2  Active Alarm Indicator will be switched on and this Alarm will be activated     To de activate Alarm  go to the Alarm Setup Mode  then push and hold Button2 until Active  Alarm Indicator is switched off  which means this alarm is no longer active  To leave Alarm  Setup Mode  push and hold Button  until digit stops to flash  You are now in the Display  Mode     How to change from 24 to 12 or from 12 to 24 Hours displaying    I recommend to do this procedure sometime aft
3.  in format HH MM SS and DD MM YY  with 10 seconds display interval    Blank  all digits are Switched Off     It   s manual Night Mode  when all digits are off    Setup Mode     Setup Mode is for changing configurable parameters  allowing     Set Current Time   Set Alarm1 time and switch it on off  Set Alarm2 time and switch it on off  Set Date   Set 12 or 24 Time Display mode    Config Mode  This mode allow you to change several configurable parameters  All  parameters numerated from 1 to 8 and in Config mode the parameter number displays in the least  left digit position   Parameter 1 defines format of Date to display  date can be set to display in the following  formats  DD MM YY or MM DD YY format   Parameter 2 defines Tube Night Brightness start time   Parameter 3 defines Tube Day Brightness start time   Parameter 4 defines Tube Day Night Brightness levels   Parameter 5 defines 24 12 hours time format   The rest parameters are not in use yet    How to connect and control your Clock    Please use 12V at minimum 200mA DC Current Power Supply   which is widely available to  buy on eBay or in your local shop     Please use only good quality  regulated and certified power adapter  as failrure to have it  could  destroy your clock due to unstable output and high levels of spikes on the 12V power line     Power adapter should have 2 1mm round connector  Inner contact is  12v  outer is Ground  contact    Clock also has 2 contact pads for soldering 12v supply  These contacts marke
4. Button1 push will increase value by one     Push Button1 to choose next digit to set  Minutes Tens will be flashing    Push Button  again in case don   t need to change Minutes tens value   Use Button2 to set correct value    Push Button  to choose next digit to set  Hours Ones digit should be flashing   Use Button2 to set correct value    Push Button  to choose next digit to set  Hours Tens should be flashing    Use Button2 to set correct value    Now Tube Day brightness time has been set     Leave Config Setup Mode by pushing and holding B1 button until digit stops blinking   You now have left Config Setup Mode  but still in Config Mode    Push B1 button to choose next parameter to set   Parameter 4 defines Alarms snooze time  Default value is 5 minutes  displayed as 0005 in  Config Mode Parameter 4  possible values to set from 0001 to 0060  which means 1 to 60    minutes     While your Clock in Config Mode and Parameter 4 has been chosen  press and hold B1 button  until least right digit is highlighted by flashing  You are now in Config Setup Mode     Use Button2 to set correct value  Every Button  push will increase value by one    Using Button  you can highlight any digit from 4 digits displayed  but you can increase value  only least right digit  As soon as you reached 60 minutes value  next Button2 push resets value to  01    Push Button1 again in case don   t need to change Minutes tens value   Use Button2 to set correct value    Push Button1 to choose next digit to s
5. Diplay brightness level  Manual adjustment  8 levels    Button2  Normal push shuts alarm buzzer off  if it was buzzing at the moment    Button2  Long push switched under tubes LED in case it has been installed on your clock   Please note  this function is optional and not included into the current assembled or kit    clock available for sale now     Button1  Normal push changes information to display     Time   Alarm1  Alarm2  Date   Time Date or Blank Mode and then back to Time     Buttonl  Long push leads to Setup Mode  where you can modify the appropriate values   Button   amp  Button2 together  Long push leads to Frequency Test Mode  Clock will display  400000  which means 400kHz frequency output has been activated    Please note  that the only way to leave these mode and come back to the normal Display mode  is to switch your Clock off   All your current time  date and alarms setups will be lost  so you    ll  need to set it up again     In Setup Mode you can do     Button 2  Normal push increments the value of highlighted digit     Button2  Long push de activate Active Alarm    works only in Alarm1 or Alarm2 Setup Mode      Button1  Normal push changes the position of highlighted digit    Button1  Long push goes back to Display Mode  where Clocks displays the current Time  Date   Alarm1 or Alarm2 sets     How to setup Time  Date and Alarms   To set or adjust the current time  push Button  until Clock starts to display time   Now push and hold Button1 until Seconds Ones 
6. can be set to 0 or 1   When it set to 0  default value   time is displayed in 24 hours format    When it set to 1  time is displayed in 12 hours format    While your Clock in Config Mode and Parameter 6 has been chosen  press and hold B1 button  until parameter value digit starts blinking  You are now in Config Setup Mode     Use B2 button to set this parameter to 0 or 1     Leave Config Setup Mode by pushing and holding B1 button until digit stops blinking  You  now have left Config Setup Mode  but still in Config Mode     Leave Config Mode by pushing and holding B1 button until your clock come back to Blank  Mode and all digits are off     You now have left Config Mode  Check that you are back in Display Mode by pushing B1  button  Clock should be switching between Display Modes    Time  Alarm1  Alarm2  Date    modes    Important Notice     This clock is designed for inside use only  Do not use this Clock outdoor under any  circumstances     Use only good quality  certified Wall Plug Power Supply  which can provide not less than  200mA DC current at 12V     Due to high voltage on the board  do not use this clock in bathroom  under rain or in the wet  and or dusty conditions    Some internal components are under High Voltage  so before handling or do any maintenance  work  be sure that power supply is switched off     Do not use the Clock without proper designed and manufactures enclosure  Only leave the Clock  in the place  where it can not be reached by children or home pe
7. d as   and     X12  connector     Connect your Clock to 12V power supply   Wrong polarity does not destroy your Clock  but it will not be functioning   Please refer to Connection Diagram to be sure you have connected it properly     Switch your Power Supply on  Clock should start to run in Display Mode and it should start  from the default current time 00 00 00     Easily control your Clock with only 2 buttons     Use Button  to change displaying information  Every single push will change it in the following  order       gt  Time   gt  Alarm    gt  Alarm2   gt  Date   gt  Time Date   gt  Blank   gt     When Clock displays Time  Alarm  or Alarm2  no separators are used  but when Date is  displayed  LED dots are used to separate Day  Month or Year digits     Use Button2 to shut off buzzer when Alarm  or Alarm2 happens     Indicator     PM Indicator   There is no AM PM time indicator  so please set 12H display mode on after lunch time  when  you can spot the difference between 12 and 24 hours display modes     Active Alarm indicates by dot on the right side of the least right IV 11 tube   In Time Display Mode  It   s on when either Alarm  or Alarm 2 or both are active   In Alarm 1 Display Mode  it   s on when Alarm 1 is active     In Alarm 2 Display Mode  it   s on when Alarm 2 is active   In Date Display Mode  it   s on when either Alarm1 or Alarm 2 or both are active     More detailed description of buttons use    In the Display mode you can do    Button2  Normal push changes 
8. digit starts to flash    Release Button1  You are in the Setup Mode now     Seconds Ones digit is highlighted by flashing  so Seconds value can be reset by pushing Button2  now     Push Button  to highlight next digit  Push Button  and it highlights Seconds Tens digit  You  can push Button2 to reset seconds value     Push Button1 to highlight next to the left digit  Now Minutes Ones are flashing   Use Button2 to set correct value  Every Button  push will increase value by one   Push Button  to choose next digit to set  Minutes Tens will be flashing    Push Button  again in case don   t need to change Minutes tens value   Use Button2 to set correct value    Push Button  to choose next digit to set  Hours Ones digit should be flashing   Use Button2 to set correct value    Push Button  to choose next digit to set  Hours Tens should be flashing    Use Button2 to set correct value    Now you set the current Time    Push Button  and it will highlight Seconds Ones again  Push Button  to reset seconds value    when you need to synchronize the seconds     Push and hold Button  until Digit stops flashing  You have left Setup Mode     To set the current date push Button  until clock displays Date    Use the same technique to set up Date    Now push and hold Button  until Years Ones start to flash    Use Button2 to set correct value    Push Button  to choose next digit to set  Year Tens will be flashing   Use Button2 to set correct value    Push Button1 to choose next digit to set  Month
9. er lunch  when PM time is started  It gives you  clear sign that you have changed the time scale     To change clock display between 12 and 24 hours mode  please go to Config Mode as it   s  described below in    How to change parameters in Config Mode    section     How to change set clock brightness    To manually change tube brightness  make sure your clock is in Display Mode  then push Button  2  Every Button2 push decreases brightness by one level of 10 in total  When you reached  lowest level  minimal tube brightness  next Button2 push restores maximum tube brightness     Now also possible to set 2 different times to change your clock brightness  Clock brightness has  11 levels to set from 0 to 10  where 0 means all tubes are switched off and 10 means maximum  brightness     Please go to Config Mode and choose Parameter 5  it will return to you 0501 value  where 05  is default value to Day brightness and 01 is default value for Night brightness     Using procedure described below in    How to change parameters in Config Mode    section   setup appropriate brightness values for Day and Night periods     To activate automatic brightness change  do not forget to set Parameter 2  Tubes Night time   and Parameter 3  Tubes Day time   must be different values  as the same values disables  automatic brightness change  You have to do it via Config Mode described below     Please note that when Day time equals Night time   automatic brightness change is not activated     Another 
10. et  Hours Ones digit should be flashing    Use Button2 to set correct value    Push Button1 to choose next digit to set  Hours Tens should be flashing    Use Button2 to set correct value    Leave Config Setup Mode by pushing and holding B1 button until digit stops blinking     You now have left Config Setup Mode  but still in Config Mode    Push B1 button to choose next parameter to set     Parameter 5 defines brightness levels for Day and Night time periods  Four digits displayed are  divided into two digits groups  Least left 2 digits represent the Day brightness value  while right  2 digits display   Night brightness value  Default value for Day brightness is set to 5  default  value for Night brightness is 01  So when you set clock to display Config Parameter 5  clock  displays it as 0501  Possible values to set for Day or Night brightness are from 00 to 10  where  00 brightness level means tubes are off and level 10 is the maximum tubes brightness     While your Clock is in Config Mode and Parameter 5 has been chosen  press and hold B1 button  until least right digit is highlighted by flashing  You are now in Config Setup Mode     Use the same technique to setup either Day or Night or both brightness levels     Leave Config Setup Mode by pushing and holding B1 button until digit stops blinking   You now have left Config Setup Mode  but still in Config Mode    Push B1 button to choose next parameter to set   Parameter 6 defines format of Hours to display  Far right digit 
11. ow to change parameters in Config Mode     Change display mode to Blank mode  To do so  in Display Mode push Button  till all digits are  off     Push and hold B2 button until clock enters Config Mode and displays any digit from 1 to 8 in  the far left position  You are now in Config Mode  If you are dong it first time  clock will  display Parameter 1 and far left digits will be 1     Use B1 button to choose config parameter from 1 to 8  At the moment only 6 parameters are  available to set there   Parameter 1 displays and available to set when far end left digit indicates 1   Parameter 2 displays and available to set when far end left digit indicates 2   and so on     Here is what parameters means and how to set it up   Parameter 1 defines format of Date to display  Far right digit can be set to 0 or 1     When it set to 0  Date displays in DD MM YY format  When it set to 1  Date displays in MM DD YY format    While your Clock in Config Mode and Parameter 1 has been chosen  press and hold B1 button  until parameter value digit starts blinking  You are now in Config Setup Mode     Use B2 button to set this parameter to 0 or 1     Leave Config Setup Mode by pushing and holding B1 button until digit stops blinking  You  now have left Config Setup Mode  but still in Config Mode     Push B1 button to choose next parameter to set    Parameter 2 defines Tube Night time for brightness change  It   s time when your tubes  brightness will be changed from Day to Night brightness    Fou
12. r digits value represents time in HHMM format  where HH     hours  00 23   MM is for  Minutes  00 59    While your Clock in Config Mode and Parameter 2 has been chosen  press and hold B1 button  until Minutes Ones digit is highlighted by flashing  You are now in Config Setup Mode   Use Button2 to set correct value  Every Button  push will increase value by one    Push Button  to choose next digit to set  Minutes Tens will be flashing    Push Button  again in case don   t need to change Minutes tens value   Use Button2 to set correct value    Push Button1 to choose next digit to set  Hours Ones digit should be flashing    Use Button2 to set correct value    Push Button  to choose next digit to set  Hours Tens should be flashing    Use Button2 to set correct value     Now Tube Night brightness time has been set     Leave Config Setup Mode by pushing and holding B1 button until digit stops blinking   You now have left Config Setup Mode  but still in Config Mode    Push B1 button to choose next parameter to set     Parameter 3 defines Tube Day time for brightness change  It   s time when your tubes brightness  will be changed from Night to Day brightness    Four digits value represents time in HHMM format  where HH     hours  00 23   MM is for  Minutes  00 59    While your Clock in Config Mode and Parameter 3 has been chosen  press and hold B1 button  until Minutes Ones digit is highlighted by flashing  You are now in Config Setup Mode     Use Button2 to set correct value  Every 
13. ts     I do not accept any liability may cause during improper or care less use of this Clock     Even this Clock is fully functioning  it sells in the form of kit  meaning you have enough  knowledge  skills to put it in the case and connect it properly     Due to constant improvement  you clock design could be slightly different from the sale  description  but technical parameters and functionality will be the same or better     The latest User Manual can be found on WEB page at    http   www kosbo com       v03 19 11 2009    
14. way to understand Button  and Button2 usage     Button  in Display Mode   Normal push     switches between Display Modes  Long push   goes to the Setup Mode    Button  in Setup Mode   Normal push     choose parameter to configure  Long push   goes back to the Display mode    Button2 in Display Mode    Normal push     switch off alarm buzz or change display brightness   Long push     switches on off under tubes LEDs  optional feature and is not included in the  current sale     Button2 in Setup Mode   Normal push     change parameter value  Long push   switch off selected alarm    Button1 and Button2 together   In Display Mode     Normal push     not defined yet  Long push   go to Frequency test Mode    In Setup Mode   Normal push     not defined yet  Long push   go to Frequency test Mode    Using Backup battery    To activate your Backup battery you have to switch your Clock off  disconnect it from power  adapter     Carefully detach tubes board from the microcontroller one     Just put jumper on the Backup battery connector J1 to activate your current time and Alarm Sets  power failure protection     Carefully attach tubes board from the microcontroller one  make sure that all inter board  connector pins fit its socket on another board     Connect your power adapter and switch clock on     To reset clock to its default values  switch off clocks power supply  disconnect power connector  and remove Back up battery jumper from J1 2 pins connector for a about 10 15 seconds     H
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
MXR6500MP-B User Guide  インパルスシリーズ  Audit et analyse des données    Samsung LE40R51B Käyttöopas  4 PLM Series Quick Start and Field Reference Guide rev 1.1.2 2  Samsung YH-920GS Instrukcja obsługi  Haier FCD-JTSA60-III User's Manual  SRE 179 E  PEB-3718VG2A User`s Manual    Copyright © All rights reserved. 