Home
Compact Controller 8 Manual
Contents
1. Button Decals 1pc 2 Pin Light Control Power Input Connector 1pc User Manual 1pc 8 Pin Light Control Output Connector 1pc Operation Warning Label Please contact supplier immediately if any component is missing or damaged MOUNTING Mount the siren unit in a location that is not exposed directly to weather elements such as the driver compartment firewall below the seat or in the trunk and away from any air bag deployment areas Mount the handheld controller in an area where it can be easily accessed by the vehicle operator and not affect the vehicle the air bag Be sure that all wiring harness connections are made prior to connecting the harness to the amplifier unit WARNING Do not interfere with the proper operation of the vehicle airbag deployment system Ensure to install Operation Warning Label in the vehicle in an area that is clearly visible to operators and passengers SAF205H Siren_v 1 WIRING Use wires that are capable of handling the required current Route the wires properly to prevent wear overheating and interference with air bag deployment Ensure that all connections are tight and double check wiring before connecting to the vehicle battery ELECTRICAL CONNECTIONS Electrical connections to the unit are made by using block plugs and screw terminals Route all wiring to the siren and secure onto block plug terminals then plug onto the siren The plug can be easily removed without unwiring whe
2. psa Compact Controller 8 Part Number PAA 165 01 Installation and operation manual Notice to installer Before installation and use read all instructions and warnings Deliver this manual to the end user of this equipment Doc No SAF205H Siren_v 1 Table of Contents GENERAL DESCRIPTION ee verre a o ey Ne ae T SRECIFICA TONGS goss tata oe INSTALLATION ete on ye Nese Ri allt ocr gi ec dd NTIS INT Saree ata ea a eer a e a ne ee Light Control Connections im 0 50 cccccasiecscsceescescendsaedersereneas PROGRAMMING S is OPERATION 006 5 RA E renee er POWER ONO a ote reece ee SIREN CONTROLES ee i es Hands Free Button ete a es ae Siren Button A ee re ee et ee cere Radio Button Hr ore er eee eer sie eee cae ee ica Manual Button ir sees io A A a cid HomiButton A Ie AE e seen tect A O en mee ar cc PIGS MPI OPONA E cat ita caian AE A erent ere cceteu A co nencnnbentns wenease EVO Sci prnaetanereumntee aut AUxiliary BUGIS edo a ere tds pete nt Ems TROUBEE SHOOTING eo rete eae sees ee eee ee SAF2C5H Siren GENERAL DESCRIPTION The SAF205H Handheld Siren Amplifier is a premium 200W unit designed for single or dual 100W speaker use with full lighting control A remote handheld controller is connected to the amplifier with a thin cable The control head comes with a noise canceling microphone for PA use and push button override in all modes It contains illuminated buttons that chang
3. 1 HRT_N HRT activate with positive HRT activate with negative 1 2 PKL_N PKL activate with positive PKL activate with negative 1 3 HILO PHASER normal operation PHASER replaced by HILO PHASER_D PHASER and HILO normal operation PHASER and HILO disabled HORN disabled replaced by PHASER HILO YELP 1 4 1 5 HORN_D HORN normal operation 1 6 SIREN_SW1 for configuration of Siren tone see Siren Modes chart 1 7 SIREN_SW2 18 TAD LED Indicator as Traffic Arrow LED Indicator Constant O IP SW2 Options PORT DIP SW2 FUNCTIONS a Aa bres During HF press HRT for more than ee urin press During HF HORN is disabled for HRT 95 secs produces Horn tone During Standby HRT and RADIO During Standby and RADIO 2 2 HRT_STBY_D produces HORN tone HRT is disabled During SIREN press MAN produces During SIREN press MAN skips to 2 3 MAN_CHANGE next tone when pressed next tone when pressed MAN Siren tone slowly winds down MAN Siren tone stops immediately 24 SHORT_MAN when released when released es D for configuration of Progressive or Non Progressive switching gt n i rt 26 LV_SW2 see LV Button Modes chart 2 7 AUTSR_D Automatic Siren at LV3 Automatic Siren Disabled at LV3 2 8 Operation Mode Light Control Program Mode SAF205H Sirer_v 1 15
4. properly to ensure safe and reliable operation Please read through all instructions thoroughly and carefully before installing the unit Failure to follow these instruc tions could result in serious damage to the unit or vehicle and may void warranties The correct mounting and wiring is key to the effectiveness of SAF205H siren Installers must read and follow installation instructions and warnings in the manual from original manufacturer The vehicle operator should verify the siren system is fastened to the vehicle securely and is functioning properly Failure to follow all safety precautions and instructions may cause property damage injury or death WARNING The installer must have good knowledge of electricity vehicle electrical systems and emergency equipment Always seek professional assistance if in doubt WARNING Sound Hazard Sound level from siren speaker gt 1204BA 10 feet may cause hearing damage i Do not operate siren without adequate hearing protection for you and anyone in immediate vicinity Ref OSHA 1910 95 for occupational noise exposure guidelines CONTENTS Inspect the product contents carefully to see if there is shipping damage or missing content Contents include 1pc Siren Amplifier 1pc 6 Extension Cable 1pc Handheld Controller with Coil Cord 1pc Extension Cable Connector 1pc Handheld Controller Mounting Bracket 1pc 15 Button Plate 1pc 12 Pin Siren Input Connector 1pc
5. 14VDC single 100W speaker Siren Output Power 200 Watts RMS MAX 14VDC dual 100W speakers Siren Frequency Tones Cycle Rates HORN O WAIL YELP PHASER HILO Cycle Rates Composite Constant 12CPM 190CPM 650CPM 60CPM Operating Temp 25 C to 60 C 15 F to 140 F 3 push button Mode switch SIREN HF RADIO Momentary push button Horn switch Momentary push button Manual Tone toggle switch Siren Controls E ENA input positive to turn on unit HRT input programmable for positive or negative operation PKL input programmable for positive or negative latching operation Side DIP switch option selectors 3 push button switch with position 3 siren activation and LED indicators Light Controls is a 4 on off lighted push button switches with replaceable legends Light Output Ragings 10A fuse on each of the 8 outputs LV 3 push buttons amp SW 4 push buttons Siren Connections Positive x 2 Negative x 2 Speaker x 2 Radio x 2 Enable Park Kill Removable TF 12 P Terminal Block Horn Ring Transfer Park Kill Power In 2 position screw terminal inputs Light Control Connections Boxed Weight LV1 LV2 LV3 push buttons 3 position screw terminal outputs SW1 SW2 SW3 SW4 push buttons 5 position screw terminal outputs Siren Amplifier 20 8em x 18 8cm x 6 90m Controller 5 6cm x 14cm x 3 3cm SAF205H Siren_v 1 INSTALLATION It is essential to install the unit
6. SW3 except Timed Momentary These auxiliary button controls may still be operated manually even if they were tumed on automatically Each time the LV button changes position the combined auxiliary button controls are turned on or off When the LV button is turned off the entire auxiliary button controls tied to a position on the LV button is turned off while the other auxiliary buttons are unaffected Set LV buttons LV1 LV2 LV3 and Auxiliary buttons Combination 1 Activate desired LV button to program 2 Press the desired auxiliary button to change LED color to Red Press the auxiliary button again to change LED color to Green to remove from combination 3 Once the LV buttons are programmed as desired save and exit programming mode by turning DIP SW2 8 PRG switch off NOTE If the unit is turned off before the DIP SW2 8 PRG switch is turned off the new programming will not be saved OPTION SWITCHES Various options can be selected by turning on or off DIP switches located on the side of the siren The DIP SWITCH functions are described below see Appendix 1 for quick reference DIP SW1 DIP SW1 1 HRT_N HRT Input Polarity The HRT input is normally activated by a positive voltage Set switch on to activate with negative DIP SW1 2 PKL_N PKL Input Polarity The PKL input is normally activated by a positive voltage Set switch on to activate with negative DIP SW1 3 HILO HiLo tone replaces Phaser tone b
7. andby HF or SIREN modes See Function Modes chart HORN It provides a simulated air horn tone when pressed and overrides all siren tones The Horn tone may be disabled entirely by setting the DIP SW1 5 HORN_D option on See OPTION SWITCHES section PA The noise canceling microphone is used for public address operation It will override any siren mode when the button on the side is pressed The volume can be adjusted through a pot switch located in the upper right corner of the control head Insert a small flat blade screwdriver into the pot switch turn clockwise direction to increase the sound level HRT Input optional The Horn Ring Transfer input may be connected to the horn ring or other switching devices Activating this input will produce Horn tone or other functions depending on the push button position PKL Input optional The Park Kill input may be connected to the vehicle door switch or other switching device to turn off any siren tone when activated The siren will remain deactivated until the vehicle is shifted into gear or the door is closed and the siren is automatically restarted SAF205H Siren_v 1 AD LIGHT CONTROLS The 3 LV buttons LV1 LV2 LV3 in the top area of the handheld controller are dedicated for primary lighting functions There are additional 4 programmable on off buttons for auxiliary lighting or other devices LV buttons The LV buttons can be set to operate as a Progressive o
8. diagram for proper fuse location below WARNING Improper circuit breakers or fuses can result in damage to the unit and or vehicle FUSE LOCATION open siren top view 10A FUSE PROGRAMMING Once the electrical connections are made and the power is available to the unit each of the three LV buttons and four auxiliary control buttons are ready to be programmed The programming mode is entered by changing the DIP switch Follow these steps to program the unit Get into program mode 1 Turn unit on with enable input 2 Enter the program mode by turning DIP SW2 8 PRG switch on Set Auxiliary Control Buttons Operation all LV buttons off 1 With all LV buttons off each auxiliary switch current operation program status is indicated on each push button See the table below for switch status definition 2 Change button operation by momentarily pushing the auxiliary button LED showing AUXILIARY button setting Red Steady PUSH on PUSH off default _Red Flashing MOMENTARY Red off TIMED MOMENTARY 10 seconds NOTE The Timed Momentary operation typically used as a Gun Lock Timer must begin with push button 3 If push button 3 is programmed as timed momentary only then push button 2 may be programmed also as a timed momentary and so on SAF205H Siren_v 1 z8 Each LV button LV1 LV2 LV3 may be programmed to automatically turn on any of the auxiliary button controls SW1
9. e can be adjusted by using a small flat blade screwdriver Speaker Output Connection Both connections must be used Two speakers may be connected in parallel VID Output Connection Option A Video Camera trigger output is activated when ever the unit is in SIREN or HF mode Not available in this model SAF205H Siren_v 1 AMPLIFIER CONNECTIONS SIR RAD VOL VOL O Q SIREN FUSE 12 P Terminal Block Plug aye Plug installed this orientation Lal Lal il a E E El DO ADA 14 AWG RED x2 Use second lead for dual speaker 14 AWG BLK x2 Use second lead for dual speaker dual speaker connect to r 18 AWG BRN x2 16 AWG dual speaker E i era ees ENA 22 AWG ORG Unit Enable like an ON OFF switch Connect to positive circuit fuse panel controlled by ignition or other switch The leads and recommended colors shown are user supplied VID 22 AWG BLU Connect to camera input ADDED DOOR SWITCH ty PKL PKL VDC 22 AWG WHITE sary PKILL VDC Switching VDC Switching example example Must set PKL_N option switch MOMENTARY FOOT SWITCH Recommended Wire Size VDC VDC Amps Size 5 10 6 22 AWG YELLOW ir 10 15 14 VDC Switching HRT HRT 7 1625 2 canoe 25 40 MEA ee adi VDC Switching example 40 60 8 RAD 22 AWG GRAY x2 Con
10. e color to indicate Status A potentiometer is also provided on the controller to adjust PA volume The SAF205H also includes 3 push buttons for primary lighting system control and 4 auxiliary output push buttons each button is capable of 10 amps current There are 3 primary operation modes HandsFree Siren and Radio with a Horn button Override and a Manual button Override The Radio and Siren volume can be adjusted on the side of the siren amplifier A Horn Ring Transfer input is available for the connection to vehicle horn ring or remote switch for hands free siren operation A Park Kill input is available for connection to a door switch etc to Stop siren tones when exiting the vehicle A 16 position DIP switch on the amplifier allows selection of various options The handheld controller is backlighted with LED s for night visibility front view Handheld controller i q front view Light control connector 5 S E E ES f coor LIGHT CONTROL LV BUTTONS E a te SW4 amp SWS MIC LED INDICATOR MIC VOL ADJUST HANDSFREE SIREN mode mode RADIO mode LIGHT CONTROL AUX SW BUTTONS AAA TELA SAF205H Siren_v 1 SPECIFICATIONS 10 16VDC negative ground A 8 5Amps 13 6VDC single 100W speaker Siren Input Current 16Amps 13 6VDC dual 100W speakers Siren Standby Current Less than 150mA Audio Frequency 200Hz 10kHz 3db Siren Output Power 40 watts 13 6VDC single 100W speaker l 100 Watts RMS MAX
11. n the unit requires servicing The power supply for the fused amplifier 12 P plug must be capable of delivering peak currents up to 50A for adequate short circuit protection and proper operation It is recommended to wire directly to the vehicle battery WARNING ensure that all wires are firmly secured onto the block plug and plug is firmly secured onto the siren Wire Size and Termination The AMPLIFIER CONNECTIONS diagram shows the minimum size of the wires used for each connection along with recommended lead color If the wire is longer than 10 ft use the next larger size ENA Input Connection This serves as the power switch for the entire unit Connect to a positive circuit controlled by the vehicle ignition switch usually a terminal at the vehicle fuse panel It is not recommended to make permanent power connection as this may drain battery HRT Input Connection The Horn Ring Transfer input allows activation by an external source of either the Horn or other function It can be set for positive or negative switching see DIP SW1 1 HRT_N under OPTION SWITCHES section PKL Input Connection The Park Kill input may be connected to the vehicle door switch or other switching device to turn off any siren tone when activated It can be set for positive or negative switching see DIP SW1 2 PKL_N under OPTION SWITCHES section RAD Input Connection Connect to radio output terminals or its speaker The Radio volum
12. nect to output jack terminals or speaker of radio Use next larger size if longer than 10ft SAF205H Siren _v 1 LIGHT CONTROL CONNECTIONS P Terminal rd 8 P Terminal Block Plug nn interna screw pressure terminal will accept up to 6 AWG for input current higher than 40 Amps Load SW1 10 Amps Max Load SW2 10 Amps Max Load SW3 10 Amps Max Load SW5 10 Amps Max x iY 0 e lt o e 5 ov 3 x amp 2 N a E lt S o gt i E 3 Load LV2 10 Amps Max Circuit Breaker Limit input up to 40 Amps Max Circuit Breaker Limit input up to 40 Amps Max x a 2 y a prd A a s Hand held controller gt A Button Decal dE Button Plate Use next gt size if longer than 10 NOTE The ole is shipped without any button plates or decals installed Place decal onto button plates then install plates onto each button SAF205H Siren_v 1 LIGHT CONTROL CONNECTIONS Power The power input for the light controls the three LV switches and the four auxiliary control switches are separate from the power inputs for siren This design helps prevent a fault in one main circuit from affecting another main circuit Fuses Breakers Each light control output is fused and should be limited to 10 Amps Proper rated circuit breakers should be connected between the power source and light control power inputs Refer to FUSE LOCATION
13. r Non progressive switching There are four modes available LV Button Modes MODE1 MODE2 MODE3 MODE4 LV Button Modes LV_SW1 off LV_SW1 off LV_SW 1 on LV_SW1 on LV_SW2 off LV_SW2 on LV_SW2 off LV_SW2 on LV1 LV1 LV1 gt LV3 LV1 E LV2 LV2 LV2 LV2 LV3 LV1 LV2 LV3 LV1 LV2 LV3 LV3 LV1 LV2 LV3 LV1 LV2 gt LV3 Progressive Non progressive Switch There are 4 different combination modes available This is configured by setting the DIP SW 2 5 LV_SW1 and DIP SW 2 6 LV_SW2 option At each of the LV switches it is possible to program the additional AUX on off buttons to be activated together LV3 Button When LV3 is switched on the siren tone is automatically activated This function can be disabled by setting the DIP SW2 7 AUTSR_D option see OPTION SWITCHES section VID Output Option The VID output is activated whenever the unit is in SIREN or HF modes Available in future models AUXILIARY Buttons The 4 lighted on off buttons are for controlling other lighting functions or devices SW1 SW3 buttons can be programmed for three operating modes such as Push On Off Momentary or Timed momentary see PROGRAMMING section SW4 button is designed to control SW4 and SW5 outputs which is mainly used to control the traffic arrow functions 13 AMIN T CIA I ist Press Activates outy output ut SW4 ps 2nd Press Acti
14. roduce Horn tone until released then the siren will retum to its previous siren tone HF settings es PHASER_D off PHASER Don Peat See ae eee Press Horn Ring HILO off HILO on as off HILO on on ff HIL WAIL gt WAIL gt oR ASS YELP gt PHASER YELP gt HILO WAIL gt ALS YELP SILENT HRT tap once MAN press once HRT quickly tap twice MAN quickly tap twice SILENT with DIP SW2 1 off HORN with DIP SW2 1 on HRT press 0 5 secs SAF205H Siren_v 1 E ie SIREN This button will activate Wail tone When pressing with MAN button together it will produce Yelp tone See Siren Modes chart Siren Modes aa 4 i ae J IA ee SIREN_SWA off SIREN SW1 off SIREN SWton MODE c ar y SIREN_SW2 off SIREN_SW2on SIREN SW2 PHASER SIREN WAIL YELP see PHASER settings SIREN MAN or HRT PHASER w MAN_ CHANGE of YELP see PHASER settings YELP _ YELP PHASER PHASER YELP SIREN MAN or HRT WAIL YELP see PHASER settings see PHASER settings RADIO This function amplifies the radio speaker input for re broadcast outside the vehicle It is also known as Radio Re broadcaster and no siren tones are available in this position The Radio Volume can be adjusted via potentiometer on the siren amplifier unit MAN It provides manual control of siren tone rise and fall while in St
15. ted when LV3 button is activated With this switch on Automatic Siren tone is disabled DIP SW2 8 PRG Turn this switch on to enter Programming mode see PROGRAMMING section SAF205H Siren_v 1 OPERATIONS POWER ON OFF The unit can be activated by applying positive voltage to the ENA terminal in the amplifier Normally this is wired to the ignition switch of the vehicle it can also be wired to another switch to act as ON OFF See AMPLIFIER CONNECTIONS diagram SIREN CONTROLS There are 5 buttons in the middle area of the handheld controller dedicated for primary operating modes of the siren Function modes Modes Standard MAN button l HRT trigger Standby SILENT MANUAL SHORT MANUAL HORN SILENT no mode selected see DIP SW2 4 SHORT_MAN see DIP SW2 2 HRT_STBY_D nad HORN RADIO RADIO RADIO ms RADIO See DIP SW2 2 HRT_STBY_D CYCLER CYCLER HF SEENI see HF settings see HF settings SIREN WAIL YELP YELP S see Siren Mode see Siren Mode see Siren Modes HF This is a standby mode dedicated for HRT Horn Ring Transfer When installing the unit the auxiliary input must be connected to the horn ring or other switching device Tap the horn ring or MAN button once to activate Wail tone then tap again to activate Yelp tone and quickly tap the horn ring twice to shut off siren tone By setting DIP SW2 1 on pressing and holding the horn ring will p
16. vates output SW5 3rd Press Activates outputs lt SW4 amp SV amp SWS 4th Press _Deactivates outputs SWA amp SW5 See DIP SW1 8 TA_D for corresponding Handheld controller LED indicator TROUBLESHOOTING SAF205H Siren has been designed to provide reliable quality service under the worst conditions If encounter any difficulties check its installation or speakers The following table represents problems and probable causes POSSIBLE CAUSE PROBLEM NO SOUND Loose wires or connectors Bad speaker or speaker wiring PA volume in the lowest sound level L NO SIREN TONE PA WORKS DISTORTED SIREN SOUND WEAK PA INTERMITTENT Pa fuse down Defective speaker SIREN VOLUME LOW High input voltage greater than 16V PKL activated PA button pressed Speaker not connected es ee Bad speaker Damaged or loose speaker housing or tip Low voltage to siren amplifier Loose wires or connectors at ENA or SPKR Speaker connected to wrong tap Low voltage to siren amplifier High resistance in speaker wiring PA volume in low position Microphone no held close to mouth Defective microphone Microphone loose connection High input voltage greater than 16V Bad speaker driver Unused wires touching vehicle ground or supply SAF205H Siren_v 1 Appendix 1 DIP SW1 Options FUNCTIONS PORT DIP SW1 a 1
17. y setting this switch on DIP SW1 4 PHASER_D Phaser HiLo tones are disabled by setting this switch on DIP SW1 5 HORN_D Horn tone is disabled by setting this switch on hart DIP SW1 6 SIREN_SW1 See Siren Mode settings chart DIP SW1 7 SIREN_SW2 See Siren Mode settings chart SAF205H Siren_v 1 DIP SW1 8 TA_D With this switch off the handheld LED indicator operates in Traffic Arrow mode With this switch on the Traffic Arrow mode is disabled Pe button St Press th Press DIP SW2 1 HRT_HF_HORN With this switch off when in HF mode Horn Ring will not produce Horn tone With this switch on when in HF mode pressing Horn Ring for more than 0 5 seconds produces Horn tone DIP SW2 2 HRT_STBY_D With this switch off when in standby ie no modes selected pressing Horn Ring or RAD button produces Horn tone With this switch on Horn Ring will not produce Horn tone DIP SW2 3 MAN_CHANGE With this switch off pressing MAN button momentarily produces next tone With this switch on pressing MAN button changes to next tone DIP SW2 4 SHORT _MAN With this switch off MAN Siren tone slowly winds down when released With this switch on MAN Siren tone stops immediately when released DIP SW2 5 LV_SW1 See LIGHT CONTROLS section DIP SW2 6 LV_SW2 See LIGHT CONTROLS section DIP SW2 7 AUTSR_D With this switch off Siren tone is automatically activa
Download Pdf Manuals
Related Search
Related Contents
ESPACES DE TRAVAIL MANUEL D`UTILISATION SV 9320 - SV_9320_Full_manual_and_Warranty Elegant Manual 706, Estates Supplement SPC-520 Bedienungsanleitung Software Quick Start Guide Manual HF_SS_PS3 Manual Cross3e : Moteur coulissant 24 v avec électronique STAMFORD P0 / P1 Copyright © All rights reserved.
Failed to retrieve file