Home

ReNEW® LED Retrofit Assembly QUICK START GUIDE

image

Contents

1. In addition to primary suspension attach a safety cable to the fixture housing An appropriate attachment point hole is provided in the fixture s housing Disconnect the fixture from power and DMX control and allow to cool before performing any cleaning or maintenance WARNING Do not use an AC power cord that is nicked frayed or damaged in any way An approved Dn replacement AC power cord may be obtained from PRG LLC Consult the User Manual for available configurations and part numbers AVERTISSEMENT Ne pas utiliser un cordon d alimentation qui est entaill us ou endommag de quelque AN fa on Un remplacement cordon d alimentation approuv peut tre obtenu partir de PRG LLC Consultez le manuel de l utilisateur pour les configurations disponibles et les num ros de pi ce 2 OVERVIEW The ReNEW LED Retrofit Assembly is intended for use with a Source Four ellipsoidal spotlight manufactured by Electronic Theatre Controls ETC The LED light engine of the RENEW Assembly replaces the tungsten light source of the original ETC Source Four spotlight INCLUDED ITEMS MAJOR COMPONENTS amp CONTROLS Head Assembly 9 Volt Battery Port AC Line Cord Power Cable Ae Safety Cable 55 9802 1000 Locking Knob Note An ETC Source Four Lens amp Shutter Assembly is not include
2. ReNEW LED Retrofit Assembly PRG QUICK START GUIDE This document provides installation and setup procedures for the PRG ReNEW LED Retrofit Assembly For complete operating instructions refer to the ReNEW LED Retrofit Assembly User Manual available at www prg com product renew For technical assistance contact PRG RH A PRG RH A 539 Temple Hill Road New Windsor NY 12553 5533 1 800 748 6562 www prg com product renew 1 IMPORTANT SAFETY INSTRUCTIONS Keep these instructions Heed all warnings Follow all instructions Do not block any of the fixture s ventilation openings Do not operate at temperatures above 40 C 104 F Do not install the fixture near any heat sources such as radiators heat registers stoves or other apparatus including amplifiers that produce heat Do not install the fixture on or near a flammable surface Do not operate the fixture with a damaged power lead If the power lead cordset is damaged it must be replaced Do not operate the fixture if glass lens is deeply scratched or cracked Damaged lenses must be replaced Use the fixture in dry locations only where humidity does not exceed 90 percent non condensing The fixture is not intended for outdoor use It is rated IP20 Mount and support the fixture only by the primary suspension holes in the yoke Suspend the fixture from a suitable structure using only hardware rated for the weight of the fixture
3. Connect DMX data cable from console to DMX IN connector at first RENEW Assembly in chain Figure 4 Step 2 If required connect additional DMX data cables from DMX THRU connectors to DMX IN connectors of remaining ReNEW Assemblies in chain Step 3 At last ReNEW Assembly in chain install male termination connector at DMX THRU connector Devices on the same DMX512 chain may not function properly without termination Step 4 Connect AC Line Cord Cable to AC IN connector at first RENEW Assembly in chain Step 5 If required connect AC jumper cables from AC THRU connectors to AC IN connectors of remaining ReNEW Assemblies in chain A imit of four 4 RENEW Assemblies can be connected using AC jumper cables Step 6 Dress and secure all cables o A DMX512 In 3 DMX512 Thru ae DMXSI Thru Termination OLR COCO Connector Power Thru Power Thru Power In Figure 4 Daisy Chain Configuration 4 QUICK SETUP Power Up Apply power to the ReNEW LED Retrofit Assembly by turning on mains circuit breaker The unit has no power on off switch When AC power is applied the RENEW menu interface will display a start up splash screen before loading the default menu for the last mode set All settings are retained while power is off Comm LED Operation A green Comm LED located at the ReNEW interface panel provides feedback during operation Solid Valid DMX received Slow Blink DMX is expected
4. amount of space occupied on the DMX universe Defines the RENEW Assembly s output state upon loss of DMX signal Adjusts the RENEW Assembly s dimmer curve Applies a smoothing filter to the DMxX input adding some delay to make the output response appear more natural Setting 1 512 1ch 8b inten 2ch 16b inten 3ch 16b fx Last Look 0 Intensity 100 Intensity Tungsten Linear None Medium Maximum f Setting Description DMX512 value 8 bit intensity control like a conventional dimmer 16 bit intensity control or finer control and smoother operation 16 bit intensity control with additional macro channel settings for automated strobe and fade Maintains the last DMX command received until valid DMX is restored Intensity goes to 0 upon loss of DMX Intensity goes to 100 upon loss of DMX Power law response similar to a tungsten fixture Linear output No filter instant response Moderate filtering reduces flicker induced by step changes to DMX input Heavy filtering slows output response by a significant amount default setting Changing the Mode If the RENEW Assembly is in a different mode than what is desired it can be changed by pressing the Mode Cancel button multiple times if necessary until the Mode menu appears Mode OM Control ft Select the desired mode from the list by pressing the and buttons Once th
5. but not received No Light No DMX expected no DMX received manual modes only Fast Blink An internal error has occurred The Comm LED goes out after 10 minutes of operation if no errors are present Menu Overview The menu system is used to configure and operate the RENEW Assembly The menu display and controls are located on the interface panel Figure 5 lt DHS Address gt eee Bal Navigation Mode The initial mode is Navigation In this mode left lt and right gt arrows are COMM displayed around the current menu title such as lt DMX Address gt WS Pressing the minus or plus buttons moves to the next or previous menu item Pressing the Mode Cancel button will return to the Mode menu Edit Mode POWER LAMP Pressing the Edit Set button switches the interface to Edit mode In this mode plus and minus symbols are displayed to the left and right of the editable value such as 001 However this is not true for the Mode menu where up down buttons are displayed Figure 5 Menu Display and Controls Detail Pressing the plus or minus buttons will increment and decrement the value Pressing the Edit Set button again sets the displayed value and returns to the Navigation mode Pressing the Mode Cancel button while in Edit mode restores the original value before editing began and returns to the Navigation mode Focus Mode Use Focus mode to t
6. d and must be installed separately See next page Menu Display Comm LED eZ DMX THRU col INTERFACE PANEL DMX Input DMX Thru AC THRU AC Input Sa AC Thru 100 240 VAC 100 240 VAC 50 60 Hz PRESS TO 50 60 Hz 10A MAX POWER LAMP 7 5A MAX oe Ag Menu Controls Figure 1 Components Overview 3 INSTALLATION Attach Source Four Lens amp Shutter Assembly Step 1 Insert ETC Source Four Lens amp Shutter Assembly not included into RENEW housing Figure 2 Step 2 Turn Source Four assembly clockwise Tighten set screw and locking knob to secure in place Locking Knob Source Four Lens amp Shutter Assembly Set Screw Figure 2 Attaching Source Four Lens Assembly Mount on Pipe Step Step Step Step 1 2 3 4 Install clamp not included on ReNEW yoke Figure 3 Carefully lift RENEW Assembly into mounting position on pipe Attach safety cable to yoke wrap around pipe and clip onto head assembly as shown Rotate head assembly to desired position and secure in place by tightening two yoke locking knobs OA At least one 1 Safety Cable MUST be used for all hanging installations and Clamp may be required by local codes not included Locking Note Source Four Lens Knob 2 Assembly not shown Figu
7. e correct mode is shown press Edit Set to enter that mode DMX Control Sets the RENEW Assembly to be controlled by DMX512 This is the default mode Manual Intensity Sets the RENEW Assembly s brightness level Manual Effects Configures effects such as pulse fade and strobe Utilities Used to access special functions and software information Manual Intensity Mode For installations that need a constant set amount of light use the Manual Intensity mode Change the mode to Man Intensity as described in CHANGING THE MODE above Once in Manual Intensity mode the display will show the intensity setting Intensity 188 Use the Edit Set button to enter editing mode and the plus and minus buttons to adjust the output level Intensity 16 Manual Effects Mode If a strobe or fade effect is desired use the Manual Effects mode There are three types of fade effects as well as a strobe and arandom strobe Adjustable settings include the effect type effect rate and effect maximum intensity Each effect will repeat until the mode or effect type is changed Pulse On Sawtooth waveform Fast turn on with gradual fade out Pulse Off Reverse sawtooth waveform Fast turn off with gradual fade up Fade Gradual fade up then gradual fade out Fast Strobe Strobe effect Random Random strobe effect Refer to the ReNEW LED Retrofit Assembly User Manual for a detailed description
8. of the Manual Effects menu system Note When using multiple RENEW Assemblies synchronization between the units is not possible in manual mode If synchronization is desired use DMX control Configuration Using 9 Volt Battery The ReNEW LED Retrofit Assembly provides a method for configuring the menu system while disconnected from the main AC power source This is accomplished using a 9 volt battery which is inserted into a port located on the side of the unit This can be used to set the DMX address before installation etc To configure unit using battery power Step 1 At side port insert and hold 9 volt battery Figure 6 Polarity does not matter The battery can be inserted in any orientation Battery must be held in place to supply power Step 2 Configure menu options as required Step 3 Remove battery Figure 6 9 Volt Battery Port ReNEW LED Retrofit Assembly Quick Start Guide go ar PLLA Version as of December 15 2014 RGR TTA PRG document number 02 9830 0002 539 Temple Hill Road 2014 Production Resource Group LLC All Rights Reserved New Windsor NY 12553 5533
9. re 3 Standard Hanging Configuration 3 Connect Data and Power The ReNEW LED Retrofit Assembly requires standard AC power 100 240 VAC 50 60 Hz 2 5A maximum The RENEW interface panel provides one Neutrik powerCON connector for power input AC IN and one for power pass through AC THRU Use the provided AC Line Cord Cable to connect power The ReNEW Assembly provides two 5 pin XLR connectors for DMX IN and DMX THRU out applications DMX IN requires a 5 pin female XLR connector and DMX THRU requires a 5 pin male XLR connector Observe the following guidelines when setting up the system Amaximum of 32 DMX devices may be connected in any one DMX512 data link However note that the maximum limit applies to the daisy chain only Your system or console may require fewer devices on a single data link path Consult your console documentation for more information Three additional RENEW Assemblies may be connected to the AC THRU connector 4 total A special Jumper Cable is available for this purpose Refer to the RENEW LED Retrofit Assembly User Manual Remember to use a DMX terminator at the end of each DMX signal chain This improves signal quality and reduces the chance of incorrect or spurious control data WARNING The ReNEW Assembly has no power on off switch Turn off the mains circuit breaker or unplug from wall socket before connecting or disconnecting the Neutrik powerCON connector To connect power and data Step 1
10. urn on the lamp momentarily for the purpose of aiming and focusing the light Enter Focus mode from anywhere in the menu by pressing Edit Set and minus buttons together The RENEW Assembly will output 100 intensity for five minutes Time can be added or removed from the timer with the plus and minus buttons DMX Operation The ReNEW LED Retrofit Assembly is factory set for DMX operation It closely emulates an 8 bit tungsten fixture and can be used as one out of the box There are several configuration changes you may want to make when setting up the ReNEW Assembly including changing the address setting the unit for 16 bit intensity control or changing the dimming curve or response time When the ReNEW Assembly is first powered on it should begin at the DMX Address screen a a aal ON Address gt If this is not the case refer to CHANGING THE MODE on the next page Set DMX address by pressing Edit Set The menu now allows you to edit the DMX address Hs Addre 255 agi Use and buttons to set the desired DMX address then press Edit Set again to save the value lt DMS Addre 2 gt 7 B15 Menu DMX Address DMX Mode DMX Fault DMX Dim Curve DMX Smoothing Menu Description Sets the RENEW Assembly s DMX address Sets the RENEW Assembly s DMX footprint also Known as DMX personality This provides a trade off between control and the

Download Pdf Manuals

image

Related Search

Related Contents

R&S®SMF100A Microwave generator  Catalogue technique  British Telecom Studio 3100  Liebert 700-3000 VA User's Manual  Crucial Micron M500DC 120GB 2.5"  The Beginner MolCAS User Manual  取扱説明書 (1.47 MB/PDF)  Leica_LeitzOptilux_UserManual_EN  安全データシート メタバナジン酸アンモニウム  NEC V652-DRD Mechanical Drawings  

Copyright © All rights reserved.
Failed to retrieve file