Contents

1. 5 2 TABLE Electric strength tests impulse tests and voltage surge tests P Test voltage applied between Voltage shape Test voltage Breakdo AC DC wn impulse surge Yes No Functional Different polarity of power supply DC 1500 No fuse disconnection Basic supplementary Primary circuit to metal enclosure AC 1707 No Mylar sheet under main board all source AC 1707 No Transformer core to primary winding T1 Core as floating AC 1707 No Transformer core to secondary winding T1 Core as floating AC 1707 No Transformer core to primary winding T2 Core as floating AC 1640 No Transformer core to secondary winding T2 Core as floating AC 1640 No Reinforced Primary circuit to secondary circuit for unit DC 4242 No Transformer primary winding to secondary winding T1 Core AC 3000 No as floating Transformer primary winding to secondary winding T2 Core AC 3000 No as floating One layer insulation tape of T1 and T2 AC 3000 No Optocoupler Renesas PS2561 Series AC 4800 No Supplementary information 1 The test voltage is according to client requirement 5 3 TABLE Fault condition tests P Ambient temperature C essusss Power source for EUT Manufacturer model type output TALING i tuer dee eoe eet eter A Fuse current A Component Fault Supply Test Fuse No voltage time V TRF No IEC60950 1B 25 C unless otherwise sp
2. 2 10 5 14 Additional insulation in wound components No such construction N A Working voltage eeeeeenI N A Basic insulation not under stress N A Supplemetary reinforced insulation N A 2 10 6 Construction of printed boards See below P 2 10 6 1 Uncoated printed boards see appended table 2 10 3 P and 2 10 4 2 10 6 2 Coated printed boards No coated printed boards N A 2 10 6 3 Insulation between conductors on the same inner N A surface of a printed board 2 10 6 4 Insulation between conductors on different layers of a N A printed board Distance through insulation N A Number of insulation layers pcs N A 2 10 7 Component external terminations see appended table 2 10 3 P and 2 10 4 2 10 8 Tests on coated printed boards and coated No such boards and N A components componets 2 10 8 1 Sample preparation and preliminary inspection N A 2 10 8 2 Thermal conditioning N A 2 10 8 3 Electric strength test see appended table 5 2 N A TRF No IEC60950 1B A T VRheinland www tuv com Page 21 of 112 Report No 16041780 001 IEC 60950 1 Clause Requirement Test Result Remark Verdict 2 10 8 4 Abrasion resistance test N A 2 10 9 Thermal cycling N A 2 10 10 Test for Pollution Degree 1 environment and N A insulating compound 2 10 11 Tests for semiconductor devices and cemented joints N A 2 10 12
3. sssssu LIPD1 DqPD2 PD3 IP protection class semRRMRReOUIPXO Altitude during operation m 2 Up to 2000 Altitude of test laboratory m sussssse below 2000 Mass of equipment kg t Approx 0 83kg Possible test case verdicts test case does not apply to the test object N A or N test object does meet the requirement P Pass test object does not meet the requirement F Fail Testing onte e d de Date of receipt of test item sess Jul 2012 Date s of performance of tests suusu Jul 2012 General remarks The test results presented in this report relate only to the object tested This report shall not be reproduced except in full without the written approval of the Issuing testing laboratory see Enclosure refers to additional information appended to the report see appended table refers to a table appended to the report Throughout this report a comma X point is used as the decimal separator Remark the samples submitted for evaluation are representative of the products from each factory TRF No IEC60950 1B A TUVRheinland www tuv com Page 7 of 112 Report No 16041780 001 Manufacturer s Declaration per sub clause 6 2 5 of IECEE 02 The applicati
4. www tuv com Page 34 of 112 Report No 16041780 001 IEC 60950 1 Requirement Test Result Remark Verdict See appended table 1 5 1 Class B Method of protection sees By protection circuit design C 1 Overload test See appended table 5 3 P C 2 Insulation See appended table P Protection from displacement of windings By insulation tape P ANNEX D MEASURING INSTRUMENTS FOR TOUCH CURRENT TESTS P see 5 1 4 Measuring instrument P E ANNEX E TEMPERATURE RISE OF A WINDING see 1 4 13 N A F ANNEX F MEASUREMENT OF CLEARANCES AND CREEPAGE DISTANCES P see 2 10 and Annex G G ANNEX G ALTERNATIVE METHOD FOR DETERMINING MINIMUM N A CLEARANCES clearances G 2 1 AC mains supply N A G 2 2 Earthed d c mains supplies N A G 2 3 Unearthed d c mains supplies N A G 2 4 Battery operation N A G 3 Determination of telecommunication network N A transient voltage V G 4 1 Mains transients and internal repetitive peaks N A G 4 2 Transients from telecommunication networks N A G 4 3 Combination of transients N A G 5 Measurement of transient voltages V N A TRF No IEC60950 1B A TUVRheinland www tuv com Page 35 of 112 Report No 16041780 001 IEC 60950 1 Requirement Test Result Remark Verdict a Transients from a mains supply N A For an a c mains supply N A For a d c mains supply N A b Transients from a telecommunication network N A G 6 Deter
5. 33 4 Result Remark Verdict e re 15 20 gt Diameters in millimeters 1 Wane Seo Note for thickness dimensions Distance from the top Thickness of probe 0 2 12 4 180 24 imd Rounded to allow rotation about hinge pin screw in one direction Note 1 The probe shall be of changing the thickness linearly However the slope shall be changed at the respective points shown in the table Note 2 The allowable dimensional tolerance of the probe is 0 127 mm Figure JA 2 Wedge probe Japanese Deviations for J60950 1 H22 2009 MITI Ordinance Clause 2 A T VRheinland www tuv com Page 107 of 112 Report No 16041780 001 IEC60950 1B ATTACHMENT National Differences Requirement Test Result Remark APPENDIX Korean National Differences according to CB Bulletin K 60950 1 P EXPLANATION FOR ABBREVIATIONS Verdict P Pass F Fail N A Not applicable Placed in the column to the right Addition Appliance inlet used N A Plugs for the connection of the apparatus to the supply mains shall comply with the Korean requirement KSC 8305 Addition EMC To be evaluated in the national N A The apparatus shall comply with the relevant approval CISPR standards Korean National Differences according to CB Bulletin www tuv com Clause Page 108 of 112 IEC60950 1B ATTACHMENT National Difference
6. 4 1 201 Add the following after the last Paragraph of Clause 4 1 4 1 201 Display devices used for television purposes Display devices which may be used for television purposes with a mass of 7 kg or more shall comply with the requirements for stability and mechanical hazards including the additional stability requirements for television receivers specified in AS NZS 60065 Add the following after Clause 6 2 2 2 Not connected to cable N A 7 2 Add the following before the first paragraph distribution system Equipment providing functions that fall only within the scope of AS NZS 60065 and that incorporate a PSTN interface are not required to comply with this Clause where the only ports provided on the equipment in addition to a coaxial cable connection and a PSTN interface are audio or video ports and analogue or data ports not intended to be used for telecommunications purposes Australian National Differences according to CB Bulletin A TUVRheinland www tuv com Page 89 of 112 Report No 16041780 001 IEC60950 1B ATTACHMENT National Differences Clause Requirement Test Result Remark Verdict ATTACHMENT TO TEST REPORT IEC 60950 1 CANADA NATIONAL DIFFERENCES Information technology equipment Safety PART 1 GENERAL REQUIREMENTS Differences according to CAN CSA C22 2 No 60950 1 07 SPECIAL NATIONAL CONDITIONS The following is a summary of the key national di
7. In NOTE 1 applicable to Table 3B delete the second sentence In Table 3D delete the fourth line conductor sizes for 10 to 13 A and replace with the following Over 10 up to and including 16 1 5 to 2 5 1 5 to 4 Delete the fifth line conductor sizes for 13 to 16 A Replace the existing NOTE by the following NOTE Z1 Attention is drawn to 1999 519 EC Council Recommendation on the limitation of exposure of the general public to electromagnetic fields 0 Hz to 300 GHz and 2006 25 EC Directive on the minimum health and safety requirements regarding the exposure of workers to risks arising from physical agents artifical optical radiation IEC60950_1B ATTACHMENT National Differences Clause Requirement Test C it is permitted for PLUGGABLE EQUIPMENT A T VRheinland Report No 16041780 001 Result Remark Deleted Replace Deleted Replace www tuv com Annex H A T VRheinland Page 66 of 112 Report No 16041780 001 IEC60950 1B ATTACHMENT National Differences Clause Requirement Test Result Remark Standards taking into account mentioned Recommendation and Directive which demonstrate compliance with the applicable EU Directive are indicated in the OJEC Replace the last paragraph of this annex by Not such equipment At any point 10 cm from the surface of the OPERATOR ACCESS AREA the dose rate shall not exceed 1 uSv h 0 1 mR h see NOTE Account i
8. Replace with The duration of burning tb shall not exceed 30 s However for printed circuit boards it shall not exceed 15 s The needle flame test shall not be carried out on parts of material classified as V 0 or V 1 according Australian National Differences according to CB Bulletin A TUVRheinland www tuv com Page 85 of 112 Report No 16041780 001 IEC60950 1B ATTACHMENT National Differences Clause Requirement Test Result Remark Verdict to IEC 60695 11 10 provided that the sample tested was not thicker than the relevant part 4 7 201 4 Testing in the event of non extinguishing material Added N A If parts other than enclosures do not withstand the glow wire tests of 4 7 201 3 by failure to extinguish within 30 s after the removal of the glow wire tip the needle flame test detailed in 4 7 201 3 is made on all parts of non metallic material which are within a distance of 50 mm or which are likely to be impinged upon by flame during the tests of 4 7 201 3 Parts shielded by a separate barrier which meets the needle flame test need not to be tested NOTE 1 If the enclosure does not withstand the glow wire test the equipment is considered to have failed to meet the requirement of clause 4 7 201 without the need for consequential testing NOTE 2 If other parts do not withstand the glow wire test due to ignition of the tissue paper and if this indicates that burring or glowing particles c
9. Document paper shredders likely to be used No such equipment in a home or home office Pluggable Equipment Type A plug configuration are required to comply with additional requirements including markings instructions protection against inadvertent reactivation of a safety interlock disconnection from the mains supply via provision of an isolating switch and protection against operator access accessibility determined via new accessibility probe amp probe wedge US National Differences according to CB Bulletin
10. No liquids provided N A in equipment is required to comply with NFPA 30 4 3 13 5 Equipment with lasers is required to meet the No laser provided N A Canadian Radiation Emitting Devices Act REDR C1370 and or Code of Federal Regulations 21 CFR 1040 as applicable 4 7 For computer room applications automated Not such an application N A information storage systems with combustible media greater than 0 76 m 27 cu ft are required to have a provision for connection of either automatic sprinklers or a gaseous agent extinguishing system with an extended discharge 4 7 3 1 For computer room applications enclosures with Not such an application N A combustible material measuring greater than 0 9 m 10 sq ft or a single dimension greater than 1 8m 6 ft are required to have a flame spread rating of 50 or less For other applications enclosures with the same dimensions require a flame spread rating of 200 or less Annex H Equipment that produces ionizing radiation is No ionizing radiation N A required to comply with the Canadian Radiation Emitting Devices Act REDR C1370 and or Code of Federal Regulations 21 CFR 1020 as applicable Canada National Differences according to CB Bulletin A TUVRheinland www tuv com Page 92 of 112 Report No 16041780 001 IEC60950 1B ATTACHMENT National Differences Requirement Test Result Remark Verdict OTHER DIFFERENCES The following key national differences are b
11. Winsis nc Shenzhen Block A Plant Junwei Xin Tongfu Yu Industria Park Zhenmei Rd Guangming New District Shenzhen Guangdong P R China input AC 115 230V 50 6OHz 5A Class Output refer to the test report WINSIS WMS 200SFX WMS 250SFX For model differences refer to the test report IEC 60950 1 2005 A1 National differences see test report 16041780 001 This CB Test Certificate is issued by the National Certification Body Ce Certificat d essai OC est tabli par l Organisme National de Certification TUVRheinland 07 08 2012 TUV Rheinland Japan Ltd Global Technology Assessment Center 4 25 2 Kita Yamata Tsuzuki ku Yokohama 224 0021 Japan Phone 81 46 914 3888 Fax 81 45914 3354 Mail info jpn tuv com Web www tuv com Signature Dipl Ing Test Report issued under the responsibility of A TUVRheinlar TEST REPORT IEC 60950 1 Information technology equipment Safety Part 1 General requirements Report Number 16041780 001 Date of issue ssssssuus Jul 28 2012 Total number of pages Total 112 pages CB Testing Laboratory T V Rheinland Guangdong Ltd AdE SSi sreci Dieci No 199 Kezhu Road Guangzhou Science City 510663 Guangzhou China Applicant s name Winsis Inc Shenzhen Addi8SsS aces Block A Plant Junwei Xin Tongfu Yu
12. st Additional symbols or marking P does not give rise to misunderstanding 1 7 2 Safety instructions and marking See below 1 7 2 1 General User s Manual provided that P contains information regarding the maximum ambient temperature 1 7 2 2 Disconnect devices The appliance inlet is N A regarded as disconnected device 1 7 2 3 Overcurrent protective device Not such equipment N A 1 7 2 4 IT power distribution systems Only for Norway P 1 7 2 5 Operator access with a tool No operator accessible area N A that needs to be accessed by the use of a tool 1 2 7 6 Ozone Not such equipment N A 1 7 3 Short duty cycles Equipment is designed for N A continuous operation 1 7 4 Supply voltage adjustment 0 eee No voltage selector N A Methods and means of adjustment reference to N A installation instructions seeees t 1 7 5 Power outlets on the equipment No power outlets provided N A 1 7 6 Fuse identification marking special fusing Marking adjacent to current P characteristics cross reference fuse F1 T5A 250V for 200W F1 T6 3A 250V for 250W 1 7 7 Wiring terminals See below 1 7 7 1 Protective earthing and bonding terminals Appliance inlet is provided P The symbol IEC 60417 5019 was located on appliance inlet Protective bonding terminal marking is shown adjacent to screw according to IEC 60417 1 IEC 5017 1 7 7 2 Terminals for a c
13. 16041780 001 Verdict 3 2 Connection to a mains supply P 3 2 1 Means of connection P 3 2 1 1 Connection to an a c mains supply P 3 2 1 2 Connection to a d c mains supply AC Source N A 3 2 2 Multiple supply connections Only one supply connection N A 3 2 3 Permanently connected equipment Not permanently connected N A equipment Number of conductors diameter of cable and conduits MM s s fecto o denos ttc 3 2 4 Appliance inlets P 3 2 5 Power supply cords No power cord provided N A 3 2 5 1 AC power supply cords N A Type aia de Lol dee No eli Rated current A cross sectional area mm AW 3 2 5 2 DC power supply cords AC Source N A 3 2 6 Cord anchorages and strain relief Appliance inlet used N A Mass of equipment kg pull N Longitudinal displacement mm 3 2 7 Protection against mechanical damage N A 3 2 8 Cord guards N A TRF No IEC60950_1B www tuv com Page 23 of 112 IEC 60950 1 A TUVRheinland Report No 16041780 001 Clause Requirement Test Result Remark Verdict Diameter or minor dimension D mm test mass g Radius of curvature of cord mm 3 2 9 Supply wiring space Not permanent connection or N A non detachable power cord type 3 3 Wiring terminals for connection of external conductors N A 3 3 1 Wiring terminals No wiring terminal
14. V time constant s See appended table 2 1 1 8 Energy hazards d c mains supply Connected to a c mains N A a Capacitor connected to the d c mains supply Po N A b Internal battery connected to the d c mains supply i N A 2 1 1 9 Audioambplifiers 5 aut eae cente Not such equipment N A 2 1 2 Protection in service access areas Compliance shall be evaluated N A for the final system 2 1 3 Protection in restricted access locations Not limited for use in restricted N A access locations 2 2 SELV circuits P 2 2 1 General requirements The secondary circuits were P tested as SELV See 2 2 1 to 2 2 4 2 2 2 Voltages under normal conditions V Between any conductors of P the SELV circuits 42 4 V peak or 60 V d c are not exceeded See appended table 2 2 2 TRF No IEC60950 1B www tuv com Page 14 of 112 IEC 60950 1 A TUVRheinland Report No 16041780 001 Clause Requirement Test Result Remark Verdict 2 2 3 Voltages under fault conditions V Single fault did not cause P excessive voltage in accessible SELV circuits Limits of 71V peak and 120V d c were not exceeded within 0 2 seconds and limits 42 4V peak and 60V d c were not exceeded for longer than 0 2 seconds 2 2 4 Connection of SELV circuits to other circuits See 2 2 2 and 2 2 3 P 2 3 TNV circuits N A 2
15. allowed part at Tmax C Test condition a b c d e Model WMS 250SFX 56 4 55 6 53 3 52 9 50 1 70 56 2 56 1 54 6 55 0 48 7 85 56 9 57 5 56 1 56 8 49 4 80 53 0 52 8 51 2 514 50 2 80 82 9 83 8 81 1 81 0 49 4 85 LF1 coil 102 5 94 4 744 70 6 50 9 105 68 6 66 1 64 1 62 5 49 0 85 704 67 5 63 2 61 3 51 2 105 64 7 62 9 60 5 59 1 52 8 85 71 7 68 9 66 4 64 4 57 0 130 75 3 71 6 69 6 67 0 60 7 130 65 5 62 8 58 2 56 9 59 0 85 66 1 63 6 59 7 58 4 59 3 85 87 8 82 4 83 1 78 9 57 3 130 T1 coil 98 2 96 9 95 5 95 1 51 9 110 60 7 61 4 60 4 61 0 90 5 110 60 4 60 9 60 0 60 4 84 1 110 57 9 574 56 3 56 1 65 6 130 54 7 55 3 53 3 53 8 76 3 100 55 7 56 2 55 1 55 6 60 8 100 U01 body 54 2 54 7 53 6 54 1 60 3 100 84 5 844 83 6 84 3 49 7 130 PCB near DB3 108 7 112 4 110 1 112 5 49 7 130 85 9 89 5 86 8 90 2 52 3 105 58 8 59 3 58 4 58 9 49 4 130 51 2 51 5 50 4 51 1 58 0 s 51 9 52 1 50 7 51 1 48 1 70 45 0 45 0 45 0 45 0 45 0 ds Temperature T of winding R R2 Y allowed EE Q Q S ME E class TRF No IEC60950 1B A TUVRheinland www tuv com Page 53 of 112 Report No 16041780 001 IEC 60950 1 Clause EL NM ee all a T M Test Result Remark Verdict The temperatures were measured under worst case normal mode defined in 1 2 2 1 and as described in sub clause 1 6 2 and at voltages as described above Supplementary information With a rated maximum ambient temperature of 45 C the maximum temperature are calculated as follows Win
16. is considered as protective earthing terminal TRF No IEC60950 1B www tuv com Page 16 of 112 IEC 60950 1 A TUVRheinland Report No 16041780 001 Clause Requirement Test Result Remark Verdict Rated current A type nominal thread diameter lup me S 2 6 4 3 Separation of the protective earthing conductor from N A protective bonding conductors 2 6 5 Integrity of protective earthing Compliance shall be evaluated N A for the final system 2 6 5 1 Interconnection of equipment This unit has its own protective P earthing bonding connection Any other units connected via the DC output connector shall provide SELV only 2 6 5 2 Components in protective earthing conductors and No switch or overcurrent P protective bonding conductors protective device provided in earthing conductors and protective bonding conductors 2 6 5 3 Disconnection of protective earth Complied P 2 6 5 4 Parts that can be removed by an operator Type C14 appliance inlet used P therefore the earth connection is made before and broken after the hazardous voltage No operator removable parts 2 6 5 5 Parts removed during servicing N A 2 6 5 6 Corrosion resistance No combination above the line P in annex J is used 2 6 5 7 Screws for protective bonding No self tapping screws are P used For the earth connection to the metal chassis a washer and a screw are used 2 6 5 8 Reliance on telecommunication n
17. output voltage V max output current A max apparent power VA ec eee eee eee eeteee tenes Current rating of overcurrent protective device A Use of integrated circuit IC current limiters 2 6 Provisions for earthing and bonding P 2 6 1 Protective earthing Green yellow wire is connected P from PE pin of appliance inlet to metal chassis Green Yellow wire is fixed reliably on the metal chassis with ring terminal star washer and screw 2 6 2 Functional earthing Secondary functional ground P separated to primary by reinforced or double insulation 2 6 3 Protective earthing and protective bonding See below P conductors 2 6 3 1 General See below P 2 6 3 2 Size of protective earthing conductors No power cord provided N A Rated current A cross sectional area mm AWG 2 6 3 3 Size of protective bonding conductors See 2 6 3 4 P Rated current A cross sectional area mm AWG Protective current rating A cross sectional area rimo s AW Qa ascen tossed dette cedet piedi 2 6 3 4 Resistance of earthing conductors and their 0 01Q 32A 2 min P terminations resistance Q voltage drop V test current A duration min esseseesss 0 029 40A 2 min 2 6 3 5 Colour of insulation eeee See sub clause 2 6 1 P 2 6 4 Terminals See below P 2 6 4 1 General See below P 2 6 4 2 Protective earthing and bonding terminals The PE pin of appliance inlet P
18. 07 Normal operation maximum Pin 2 2 08 temperature was T1 coil 76 1 C T1 core 64 8 C T2 coil 44 2 C T2 core 41 1 C Ambient 28 8 C no damage no hazards U2 Pin 1 0 C 253Vac 10min F1 2 07 Normal operation no damage 2 08 no hazards U2 Pin 3 S C 253Vac 10min F1 2 07 gt Unit shut down immediately no Pin 4 0 03 damage no hazards U2 Pin 3 0 C 253Vac 10min F1 2 07 Normal operation no damage 2 08 no hazards TRF No IEC60950 1B www tuv com Page 56 of 112 A TUVRheinland Report No 16041780 001 IEC 60950 1 Requirement Test Result Remark Verdict U01 Pin 1 s c 253Vac 10min F1 2 07 gt Unit shut down immediately Pin 2 0 18 except 5Vsb no damage no hazards U01 Pin1 o c 253Vac 10min F1 2 07 Unit shut down immediately 0 18 except 5Vsb no damage no hazards U01 Pin 3 s c 253Vac 10min F1 2 07 Unit shut down immediately Pin 4 0 18 except 5Vsb no damage no hazards U01 Pin3 o c 253Vac 10min F1 2 07 Unit shut down immediately 0 18 except 5Vsb no damage no hazards U02 Pin 1 253Vac 10min F1 2 07 Unit shut down immediately Pin 2 0 18 except 5Vsb no damage no hazards U02 Pin 1 253Vac 10min F1 2 07 gt Unit shut down immediately 0 18 except 5Vsb no damage no hazards U02 Pin 3 253Vac 10min F1 2 07 gt Normal operation no damage Pin 4 2 06 no hazards U02 Pin 3 2
19. 2 Equipment with handles is required to comply with No handle on equipment N A special loading tests 5 1 8 3 Equipment intended to receive telecommunication No TNV circuits N A ringing signals is required to comply with a special touch current measurement tests 5 3 7 Internal e g card cage SELV circuit connectors Considered P and printed wiring board connectors that are accessible to the operator and that deliver power are to be overloaded During abnormal operating testing if a circuit is interrupted by the opening of a component the test shall be repeated twice three tests total using new components as necessary 6 4 Equipment intended for connection to No TNV circuits N A telecommunication network outside plant cable is required to be protected against overvoltage from power line crosses in accordance with 6 4 and Annex NAC M 2 Continuous ringing signals up to 16 mA only are No TNV circuits N A permitted if the equipment is subjected to special installation and performance restrictions Annex NAD Equipment connected to a telecommunication and No such equipment N A cable distribution networks and supplied with an earphone intended to be held against or in the ear is required to comply with special acoustic pressure requirements Canada National Differences according to CB Bulletin A TUVRheinland www tuv com Page 94 of 112 Report No 16041780 001 IEC60950 1B ATTACHMENT Nati
20. 2 SELV limits For Normal Conditions 2 2 8 SELV Limits For Abnormal Conditions 2 6 3 4 Resistance of Earthing Circuit 2 9 2 Humidity Conditioning 2 10 2 Working Voltage Over Insulation 2 10 3 Clearance Measurement 2 10 4 Creepage Distance Measurement 4 2 2 Steady Force Test 10N 4 2 4 Steady Force Test 250N 4 5 2 Maximum Temperature Test 4 5 5 Ball Pressure Test 5 1 6 Touch Current Test 52 Electric Strength Test 5 8 Fault Condition Test A Glow wire test Note Unless otherwise specified models WMS 200SFX and WMS 250SFX were selected for these tests Details see appended clauses and tables TRF No IEC60950 1B A TUVRheinland www tuv com Page 4 of 112 Report No 16041780 001 Summary of compliance with National Differences Summary of compliance with National Differences to IEC 60950 1 2005 A1 2009 and EN 60950 1 2006 A11 2009 A1 2010 A12 2011 for explanation of codes see below EU Group Differences EU Special National Conditions CA CH DE DK FI GB IL KR SE SI Explanation of used codes CA Canada CH Switzerland DE Germany DK Denmark Fl Finland GB United Kingdom IL Israel KR Republic of Korea SE Sweden Sl Slovenia Summary of compliance with National Differences to IEC 60950 1 2005 2nd Edition for explanation of codes see below US Explanation of used codes US United States of America Summary of compliance with National Difference
21. 3 1 Limits No TNV circuit N A Type of TNV circuits ccccceeeceeeeeeeeeseeeeeeeeeeeees 2 3 2 Separation from other circuits and from accessible N A parts 2 3 2 1 General requirements N A 2 3 2 2 Protection by basic insulation N A 2 3 2 3 Protection by earthing N A 2 3 2 4 Protection by other constructions N A 2 3 3 Separation from hazardous voltages N A Insulation employed ssesssssss 2 3 4 Connection of TNV circuits to other circuits N A Insulation employed essesssssss 2 3 5 Test for operating voltages generated externally N A 2 4 Limited current circuits N A 2 4 1 General requirements N A 2 4 2 Limit values N A Frequency Hz iani E Measured current MA ceeeesseeeeeeeeeeeeeeeeneeeees Measured voltage V eeeesceeeeesseeeeeeeeeeeeeeeeneeees Measured circuit capacitance nF or pF 2 4 3 Connection of limited current circuits to other circuits N A 2 5 Limited power sources N A TRF No IEC60950_1B A TUVRheinland www tuv com Page 15 of 112 Report No 16041780 001 IEC 60950 1 Clause Requirement Test Result Remark Verdict a Inherently limited output N A b Impedance limited output N A c Regulating network limited output under normal N A operating and single fault condition d Overcurrent protective device limited output N A Max
22. 4 2 8 7 and 3 2 5 apply and in addition a cord connector of power supply cord set mating with appliance inlet complying with the standard sheet of IEC 60320 1 shall comply with relevant standard sheet of IEC 60320 1 Replace Note 1 with the following Note 1 A JIS or an IEC component standard is considered relevant only if the component in question clearly falls within its scope 1 5 2 Replace first sentence in the first dashed Considered P paragraph with the following a component that has been demonstrated to comply with a JIS component standard harmonized with the relevant IEC component standard or where such JIS component standard is not available a component that has been demonstrated to comply with the relevant IEC component standard shall be checked for correct application and use in accordance with its rating Add a note after the first dashed paragraph as follows Note 1 See 1 7 5A when Type C 14 appliance coupler rated 10 A per IEC 60320 1 is used with an equipment rated not more than 125 V and rated more than 10 A Replace first sentence in the third dashed paragraph as follows where no relevant IEC component standard or JIS component standard harmonized with the relevant IEC component standard exists or where components are used in circuits not in accordance with their specified rating the components shall be tested under the conditions occurring in the equipment 1 7 1 Replace fifth dashe
23. A N A N A A TUVRheinland www tuv com Page 76 of 112 Report No 16041780 001 IEC60950 1B ATTACHMENT National Differences Clause Requirement Test Result Remark Verdict ATTACHMENT TO TEST REPORT IEC 60950 1 FINLAND NATIONAL DIFFERENCES Information technology equipment Safety PART 1 GENERAL REQUIREMENTS Differences according to EN 60950 1 2006 A11 2009 A1 2010 Attachment Form No FI ND IEC60950 1 B Attachment Originator SGS Fimko Ltd Master Attachment Date 2010 04 Copyright 2010 IEC System for Conformity Testing and Certification of Electrical Equipment IECEE Geneva Switzerland All rights reserved National Differences P General See also Group Differences EN 60950 1 2006 A1 1 A1 P 1 5 7 1 In Finland resistors bridging BASIC INSULATION in N A CLASS I PLUGGABLE EQUIPMENT TYPE A must comply with the requirements in 1 5 7 1 In addition when a single resistor is used the resistor must withstand the resistor test in 1 5 7 2 1 5 9 4 In Finland the third dashed sentence is N A applicable only to equipment as defined in 6 1 2 2 of this annex 1 7 2 1 In Finland CLASS PLUGGABLE EQUIPMENT Appliance inlet used N A TYPE A intended for connection to other equipment or a network shall if safety relies on connection to protective earth or if surge suppressors are connected between the network
24. Any warning shall not be used instead of the machines structure for preventing access to hazardous moving parts Document shredding machines shall comply with the following requirements Push the test finger Figure JA 1 into all openings in MECHANICAL ENCLOSURES without applying additional force It shall not be possible to touch hazardous moving parts with the test finger The document shredding machine is installed as intended and all face of MECHANICAL ENCLOSURES are subjected to this test Before testing with the test finger remove the parts detachable without a tool Push the wedge probe Figure JA 2 into the document slot And against all directions of openings if straight cutting type a force of 45 N shall apply to the probe and 90 N if cross cutting type In this case the weight of the probe shall not influence the test Before testing withy the test finger remove the parts detachable without a tool It shall not be possible to touch any hazardous moving parts including the shredding roller or the mechanical section for shedding with the probe Japanese Deviations for J60950 1 H22 2009 MITI Ordinance Clause 2 www tuv com Page 106 of 112 A T VRheinland Report No 16041780 001 Clause Requirement Test See Note 1 ot By L OO uy Details of the top of wedge IEC60950 1B ATTACHMENT National Differences 30 i 27 4 E24 p
25. N A excessive currents and short circuits in the PRIMARY CIRCUIT of DIRECT PLUG IN EQUIPMENT tests according to 5 3 shall be conducted using an external protective device rated 30 A or 32 A If these tests fail suitable protective devices shall be included as integral parts of the DIRECT PLUG IN EQUIPMENT so that the requirements of 5 3 are met 2 10 5 13 In Finland Norway and Sweden there are No TNV N A additional requirements for the insulation see 6 1 2 1 and 6 1 2 2 of this annex 3 2 1 1 In Switzerland supply cords of equipment having For appliance inlet appliance N A a RATED CURRENT not exceeding 10 A shall be should be considered during provided with a plug complying with SEV 1011 or national approval IEC 60884 1 and one of the following dimension sheets SEV 6532 2 1991 Plug Type 15 3P N PE 250 400 V 10A SEV 6533 2 1991 Plug Type 11 L N 250 V 10A SEV 6534 2 1991 Plug Type 12 L N PE 250 V 10A In general EN 60309 applies for plugs for currents exceeding 10 A However a 16 A plug and socket outlet system is being introduced in Switzerland the plugs of which are according to the following dimension sheets published in February 1998 SEV 5932 2 1998 Plug Type 25 3L N PE 230 400 V 16 A SEV 5933 2 1998 Plug Type 21 L N 250 V 16A SEV 5934 2 1998 Plug Type 23 L N PE 250 V 16A www tuv com Requirement Test A T VRheinland Page 70 of 112 Report No 160417
26. Page 82 of 112 Report No 16041780 001 IEC60950 1B ATTACHMENT National Differences Clause Requirement Test Result Remark Verdict Replace footnote 1 with the following 1 This nominal cross sectional area is only allowed for Class Il appliances if the length of the power supply cord measured between the point where the cord or cord guard enters the appliances and the entry to the plug does not exceed 2 m 0 5 mm three core supply flexible cords are not permitted see AS NZS 3191 Delete Note 1 4 1 Add the following after the last Paragraph of Clause No such device N A 4 1 4 1 201 Display devices used for television purposes Display devices which may be used for television purposes with a mass of 7 kg or more shall comply with the requirements for stability and mechanical hazards including the additional stability requirements for television receivers specified in AS NZS 60065 4 3 6 Replace paragraph three with Should be considered during N A Equipment with a plug portion suitable for insertion national approva into a 10 A 3 pin flat pin socket outlet complying with AS NZS 3112 shall comply with the requirements in AS NZS 3112 for equipment with integral pins for insertion into socket outlets 4 3 13 5 Add the following to the end of the first paragraph Added P or AS NZS 2211 1 4 7 Add the following paragraph Added P For alternative tests refer to clause 4 7 201 4 7 201 A
27. Report No 16041780 001 IEC60950 1B ATTACHMENT National Differences Clause Requirement Test Result Remark Verdict ATTACHMENT TO TEST REPORT IEC 60950 1 ISRAEL NATIONAL DIFFERENCES Information technology equipment Safety PART 1 GENERAL REQUIREMENTS Differences according to SI 60950 Part 1 1 1 1 Replace the the text of Note 3 as follows Not such equipment N A The requirements of Israel Standard SI 60065 may also be used to meet safety requirements for multimedia equipment See IEC Guide 112 Guide on the safety of multimedia equipment 1 6 The clause is applicable with the following addition 1 6 1 Add following note In Israel this clause is applicable subject to the Electricity Law 1954 its regulations and revisions 1 7 The clause is applicable with the following Added P additions Subclause 1 7 201 shall be added at the beginning of the clause as follows 1 7 201 Marking in the Hebrew language Should be considered during N A The marking in the Hebrew language shall be in nationalapproval accordance with the Consumer Protection Order Marking of goods 1983 In addition to the marking required by clause 1 7 1 the following details shall be marked in the Hebrew language The details shall be marked on the apparatus or on its package or on a label properly attached to the apparatus or on the package by bonding or sewing in a manner that the label cannot be
28. Science And 250Vac min 85 E315567 C X2 type Bleeder Various Various Max 680kQ Resistor R1 min 1 4W Y Capacitors Murata KY Min 250 V IEC EN 60384 14 VDE 115455 CY1 CY2 max 4700 pF UL E37921 CY3 min 85 C min Optional Y2 type Alternative TDK EPC CS Min 250 V IEC EN 60384 14 VDE 138559 max 4700 pF UL E37861 min 85 C min Y2 type Alternative Jya Nay JY Min 250 V IEC EN 60384 14 VDE max 4700 pF 40001827 UL min 85 C min E201384 Y2 type Alternative Matsushita TS Min 250 V IEC EN 60384 14 VDE 087472 max 4700 pF UL E62674 min 85 C min Y2 type Alternative Success SE Min 250 V IEC EN 60384 14 VDE 122995 max 4700 pF UL E114280 min 85 C min Y2 type Alternative Welson KL Min 250 V IEC EN 60384 14 VDE 116772 max 4700 pF UL E104572 min 85 C min Y2 type Bridge diode Various Various Min 4A BD1 min 600V Thermistor Various Various Min 5Q at 25 C THR1 min 3A optional Electrolytic Various Various 330UF to 470uF Capacitors min 400V min C1 C2 85 C Transistor Q1 Various Various Min 9A min Q2 500V Current sense Various Various Min 0 16Q min x resistor R22 2W TRF No IEC60950 1B www tuv com Page 42 of 112 A TUVRheinland Report No 16041780 001 Clause U01 U02 U2 Alternative Alternative oo o ae Isolator S
29. Wallts 3 3V 45V 412V 12V 5Vsb 5V 3 3V Total Power Power W max W WMS 115Vac 230Vac 10 11 8 0 5 2 88 200 200SFX 50 60Hz 5A WMS 12 11 12 0 5 2 95 250 250SFX TRF No IEC60950 1B A TUVRheinland www tuv com Page 8 of 112 Report No 16041780 001 Abbreviations used in the report normal conditions N C single fault conditions S F C functional insulation OP basic insulation BI double insulation DI supplementary insulation SI between parts of opposite polarity BOP reinforced insulation RI shorted circuit S C opened circuit O C over load O L Indicate used abbreviations if any TRF No IEC60950 1B www tuv com Page 9 of 112 A T VRheinland Report No 16041780 001 between a c mains and antenna or coaxial cable IEC 60950 1 Clause Requirement Test Result Remark Verdict 1 GENERAL P 1 5 Components 1 5 1 General Components which were found to affect safety aspects comply with the requirements of this standard or within the safety aspects of the relevant IEC component standards Comply with IEC 60950 1 or relevant component see appended tables 1 5 1 P standard 1 5 2 Evaluation and testing of components Components which are P certified to IEC EN and or national standards are used correctly within their ratings Components not covered by IEC EN standards are tested under the conditions presen
30. between PCB Films US LP 0 25mm min and Chassis Alternative Various Various VTM 2 or better UL 0 25mm min DC Fan Xin Wang Xin XWX0815M12S 12V 0 17A min IEC EN 60950 1 TUV SUD 80x80x15mm 29 8 CFM B1001 72554001 UL E335638 Primary Various 1015 Min 80 C min UL internal wire 300V min 20AWG VW 1 Primary Wonderful 1015 Min 105 C min UL E77981 earthing wire 300V min 18AWG VW 1 Alternative Various Various Min 105 C min UL 300V min 18AWG VW 1 Insulation Kingboard KB 6160C V 0 130 C UL UL E123995 tube for DC Laminates Fan Macao Commercial Offshore Ltd Supplementary information 1 Provided evidence ensures the agreed level of compliance See OD CB2039 2 In Optocoupler technical data column where Dti means distance through insulation Int means internal creepage distance Ext means external creepage distance TRF No IEC60950 1B A TUVRheinland www tuv com Page 45 of 112 Report No 16041780 001 IEC 60950 1 Requirement Test Result Remark Verdict 1 5 1 TABLE Opto Electronic Devices P Manufacturer See table 1 5 1 Ty Latet ke aie Hout Seetable 151 Separately tested sss See table 1 5 1 Bridging insulation See table 1 5 1 External creepage distance See table 1 5
31. easily removed 1 Name of the apparatus and it commercial designation 2 Manufacturer s name and address If the apparatus is imported the importer s name and address 3 Manufacturer s registered trademark if any 4 Name of the model and serial number if any 5 Country of manufacture 1 7 2 1 The following shall be added to the clause Should be considered during N A All the instructions and warnings related to safety nationaapproyal shall also be written in the Hebrew language Israel National Differences according to CB Bulletin A TUVRheinland www tuv com Page 96 of 112 Report No 16041780 001 IEC60950 1B ATTACHMENT National Differences Clause Requirement Test Result Remark Verdict 2 The clause is applicable with the following P additions 2 9 4 The following shall be added at the beginning of P the clause In Israel according to the Electricity Law 1954 and the Electricity Regulations Earthing and means of protection against electricity of voltages up to 1 000V 1991 seven means of protection against electrocution are permitted as follows 1 TN S Network system earthing TN C S Network system earthing 2 TT Network system earthing 3 IT Network Insulation Terre 4 Isolated transformer 5 Safety extra low voltage SELV or ELV 6 Residual current circuit breaker 30 mA lA 7 Reinforced insulation Double insulation class 1 2 201 Preventi
32. equipment 4 3 4 Add the following after the first sentence N A This requirement also applies to those connections in Class 0l equipment where CLEARANCE or CREEPAGE DISTANCES over BASIC INSULATION would be reduced to less than the values specified in 2 10 5 1 3 Add a note after the first paragraph as follows N A Note Attention should be drawn to that majority of three phase power system in Japan is of delta connection and therefore in that case test is conducted using the test circuit from IEC 60990 figure 13 Japanese Deviations for J60950 1 H22 2009 MITI Ordinance Clause 2 www tuv com Page 102 of 112 A T VRheinland Report No 16041780 001 IEC60950 1B ATTACHMENT National Differences Clause Requirement Test Result Remark Verdict 5 1 6 Table Replace Table 5A of this Sub Clause by Replaced P 5A Table 5A Maximum current Type of equipment Terminal A of Maximum Maximum measuring instrument TOUCH PROTECTIVE connected to CURRENT CONDUCTOR 1 CURRENT mA r m s ALL equipment Accessible parts and 0 25 circuits not connected to protective earth HAND HELD 0 75 Movable Other Than 3 5 Hand Held But Including Transportable Equipment Equipment main Pedi Pluggable Type protective earthing 3 5 z terminal ALL other STATIONARY EQUIPMENT if any CLASS EQUIPMENT not subject to the c
33. following notes after first paragraph Note 1 Transportable or similar equipment that are relocated frequently for intended usage should not be designed as Class or Class 0l equipment unless it is intended to be installed by service personnel Note 2 Considering wiring circumstance in Japan equipment intended to be installed where the provision for earthing connection is unlikely should not be designed as Class or Class Ol equipment unless it is intended to be installed by service personnel Should be considered during N A national approval Built in equipment should be N A considered during national approval Built in equipment should be N A considered during national approval Japanese Deviations for J60950 1 H22 2009 MITI Ordinance Clause 2 A T VRheinland www tuv com Page 99 of 112 Report No 16041780 001 IEC60950 1B ATTACHMENT National Differences Clause Requirement Test Resut Remak Remark Verdict 1 5 1 Replace the first paragraph with the follows Considered P Where safety is involved components shall comply either with the requirements of this standard with the safety aspects of the relevant JIS component standard or IEC component standards in case there is no applicable JIS component standard is available However a component that falls within the scope of METI Ministerial ordinance No 85 is properly used in accordance with its marked ratings requirements of 1 5
34. if it does not exceed the extreme operating conditions in Table 2 of CAN CSA C22 2 No 235 and if it is part of a range that extends into the Table 2 Normal Operating Conditions Likewise a voltage rating shall not be lower than the specified Normal Operating Conditions unless it is part of a range that extends into the Normal Operating Conditions Canada National Differences according to CB Bulletin www tuv com Clause 1 7 7 Page 90 of 112 A TUVRheinland Report No 16041780 001 IEC60950 1B ATTACHMENT National Differences Result Remark Verdict Requirement Test Wiring terminals intended to supply Class 2 outputs in accordance with CEC Part 1 or NEC shall be marked with the voltage rating and Class 2 or equivalent Marking shall be located adjacent to the terminals and shall be visible during wiring Where a fuse is used to provide Class 2 Limited Power Source or TNV current limiting it shall not be operator accessible unless it is not interchangeable No such fuse used N A N A 2 7 1 Suitable NEC CEC branch circuit protection rated at the maximum circuit rating is required for all standard supply outlets and receptacles such as supplied in power distribution units if the supply branch circuit protection is not suitable Power distribution transformers distributing power at 100 volts or more and rated 10 kVA or more require special transformer overcur
35. insulating compound completely filling the casing so that CLEARANCES and CREEPAGE DISTANCES do not exist if the component passes the electric strength test in accordance with the compliance clause below and in addition A passes the tests and inspection criteria of 2 10 11 with an electric strength test of 1 5 kV multiplied by 1 6 the electric strength test of 2 10 10 shall be performed using 1 5 kV and E is subject to ROUTINE TESTING for electric strength during manufacturing using a test voltage of 1 5 kV IEC60950 1B ATTACHMENT National Differences Requirement Test A T VRheinland Report No 16041780 001 Result Remark Verdict No such high touch current No TNV N A N A www tuv com 6 1 2 2 Requirement Test A T VRheinland Page 73 of 112 Report No 16041780 001 IEC60950 1B ATTACHMENT National Differences It is permitted to bridge this insulation with an No TNV optocoupler complying with 2 10 5 4 b It is permitted to bridge this insulation with a capacitor complying with EN 60384 14 2005 subclass Y2 A capacitor classified Y3 according to EN 60384 14 2005 may bridge this insulation under the following conditions the insulation requirements are satisfied by having a capacitor classified Y3 as defined by EN 60384 14 which in addition to the Y3 testing is tested with an impulse test of 2 5 kV defined in EN 60950 1 2006 6 2 2 1
36. insulation Test Measured Measured Measure voltage clearance creepage d V mm dist mm distance thr insul mm number of layers Primary RI 3000Vac 6 0 6 0 2 layers winding to secondary winding Core to BI 1707Vac 3 0 3 0 Primary winding Core to SI 1707Vac 3 0 3 0 2 layers secondary winding supplementary information Concentric windings on El 33 type bobbin at least two layers insulation tape used between primary and secondary windings Distance tape of 6 0 mm on bottom side and 3 0 mm on top side of windings Outer winding is primary winding Core is considered as floating circuit TRF No IEC60950_1B A TUVRheinland www tuv com Page 62 of 112 Report No 16041780 001 IEC 60950 1 Requirement Test Result Remark Verdict C 2 TABLE transformers T2 P Loc Tested insulation Working Working Required Required Required Required voltage voltage electric clearance creepage distance peak V rms V strength mm distance thr insul mm 2 10 2 2 10 2 5 2 2 10 3 2 10 4 2 10 5 Primary RI 428 250 3000Vac 4 2 5 0 0 4 winding to secondary winding Core to BI 428 250 1640Vac 2 1 2 5 Primary winding Core to SI 428 250 1640Vac 2 1 2 5 0 4 secondary winding Loc Tested insulation Test Measured Measured Measure voltage clearance creepage d V mm dist mm distance thr insul mm number of layers Primary RI 3000Vac 6 0 6 0 2
37. layers winding to secondary winding Core to BI 1640Vac 3 0 3 0 Primary winding Core to SI 1640Vac 3 0 3 0 2 layers secondary winding supplementary information Concentric windings on EEL 19 type bobbin at least two layers insulation between primary and secondary windings Distance tape of 6 0 mm on bottom side and 3 0 mm on top side of windings Outer winding is primary winding Core is considered as floating circuit TRF No IEC60950_1B A T VRheinland www tuv com Page 63 of 112 Report No 16041780 001 IEC60950 1B ATTACHMENT National Differences Clause Requirement Test Result Remark Verdict ATTACHMENT TO TEST REPORT IEC 60950 1 EUROPEAN GROUP DIFFERENCES AND NATIONAL DIFFERENCES Information technology equipment Safety PART 1 GENERAL REQUIREMENTS Differences according to EN 60950 1 2006 A11 2009 A1 2010 Attachment Form No EU GD IEC60950 1B Attachment Originator SGS Fimko Ltd Master Attachment Date 2010 04 Copyright 2010 IEC System for Conformity Testing and Certification of Electrical Equipment IECEE Geneva Switzerland All rights reserved EN 60950 1 2006 A11 2009 A1 2010 CENELEC COMMON MODIFICATIONS IEC 60950 1 GROUP DIFFERENCES CENELEC common modifications EN Clause Requirement Test Result Remark Verdict Contents Add the following annexes P Annex ZA n
38. mains supply conductors Appliance inlet provided N A TRF No IEC60950_1B A TUVRheinland www tuv com Page 12 of 112 Report No 16041780 001 IEC 60950 1 Clause Requirement Test Result Remark Verdict 1 7 7 3 Terminals for d c mains supply conductors No d c mains supply N A 1 7 8 Controls and indicators P 1 7 8 1 Identification location and marking N A 1 7 8 2 GOlQUIS deceit petites e eet Rode iod N A 1 7 8 3 Symbols according to IEC 60417 N A 1 7 8 4 Markings using figures N A 1 7 9 Isolation of multiple power sources Only one supply from the N A mains 1 7 10 Thermostats and other regulating devices No such componentes N A provided 1 7 11 Durability The label was subjected to P the permanence of marking test The label was rubbed with cloth soaked with water for 15 sec And then again for 15 sec With the cloth soaked with petroleum spirit After this test there was no damage to the label The marking on the label did not fade There was no curling and lifting of the label edge 1 7 12 Removable parts No removable part N A 1 7 13 Replaceable batteries ssessss i No battery provided N A Language s 4 echec e dies 1 7 14 Equipment for restricted access locations Not intended for use in N A restricted access locations 2 PROTECTION FROM HAZA
39. of 112 Report No 16041780 001 IEC60950 1B ATTACHMENT National Differences Clause Requirement Test Result Remark Verdict 6 2 2 1 Delete Note 2 No TNV N A Add the following after the first paragraph In Australia this variation does not apply in New Zealand the electrical separation is subjected to 10 impulses of alternating polarity using the impulse test generator of annex N for 10 700 us impulses The interval between successive impulses is 60 s and the initial voltage UC is for 6 2 1 a 7 0 kV for hand held telephones and for headsets and 2 5 kV for other equipment and for 6 2 1b and 6 2 16 1 5 kV NOTE 201 The 7 kV impulse simulates lightning surges on typical rural and semi rural network lines NOTE 202 The 2 5 kV impulse for 6 2 1a was chosen to ensure adequacy of the insulation concerned and does not necessarily simulate likely overvoltages 6 2 2 2 Delete the note No TNV N A Add the following after the second paragraph In Australia this variation does not apply in New Zealand the a c test voltage is for 6 2 1a 3 kV and for6 2 1b and 6 2 1c 1 5 kV NOTE 201 Where there are capacitors across the insulation under test it is recommended that d c test voltages are used NOTE 202 The 3 kV and 1 5 kV values have been determined considering the low frequency induced voltages from the power supply distribution system 7 2 Add the following before the fi
40. power supply cord with conductor of 1 25 mm2 is allowed for equipment with a rated current over 10 A and up to and including 13 A In the United Kingdom the range of conductor sizes of flexible cords to be accepted by terminals for equipment with a RATED CURRENT of over 10 A up to and including 13 A is 1 25 mm to 1 5 mm nominal cross sectional area In the United Kingdom the torque test is performed using a socket outlet complying with BS 1363 part 1 1995 including Amendment 1 1997 and Amendment 2 2003 and the plug part of DIRECT PLUG IN EQUIPMENT shall be assessed to BS 1363 Part 1 12 1 12 2 12 3 12 9 12 11 12 12 12 13 12 16 and 12 17 except that the test of 12 17 is performed at not less than 125 C Where the metal earth pin is replaced by an Insulated Shutter Opening Device ISOD the requirements of clauses 22 2 and 23 also apply In Ireland DIRECT PLUG IN EQUIPMENT is known as plug similar devices Such devices shall comply with Statutory Instrument 526 1997 National Standards Authority of Ireland Section 28 Electrical plugs plug similar devices and Sockets for domestic use Regulations 1997 IEC60950 1B ATTACHMENT National Differences Requirement Test A T VRheinland Report No 16041780 001 Result Remark Verdict For appliance inlet appliance should be considered during national approval For appliance inlet appliance should be considered during national approval
41. should be taken of the cumulative effect of small parts adjacent to each other for the possible effect of propagating fire from one part to another Compliance is checked by tests of 4 7 201 2 4 7 201 3 4 7 201 4 and 4 7 201 5 For the base materials of printed boards compliance is checked by the test of 4 7 201 5 The tests shall be carried out on parts of non metallic material which have been removed from the apparatus When the glow wire test is carried out the parts shall be placed in the same orientation as they would be in normal use These tests are not carried out on internal wiring 4 7 201 2 Parts of non metallic material are subjected to glow Metal enclosure N A wire test of AS NZS 4695 2 11 which is carried out at 550 C Parts for which the glow wire test cannot be carried out such as those made of soft or foamy material shall meet the requirements specified in ISO 9772 for category FH 3 material The glow wire test shall be not carried out on parts of materials classified at least FH 3 according to ISO 9772 provided that the sample was not thicker than the relevant part 4 7 201 3 Testing of insulating materials PCB bobbin P Australian National Differences according to CB Bulletin A TUVRheinland www tuv com Page 84 of 112 Report No 16041780 001 IEC60950 1B ATTACHMENT National Differences Clause Requirement Test Result Remark Verdict Parts of insulating materials sup
42. som ar kopplad till skyddsjord via jordat v gguttag och eller via annan utrustning och samtidigt ar kopplad till kabel TV n t kan i vissa fall medf ra risk f r brand F r att undvika detta skall vid anslutning av utrustningen till kabel TV n t galvanisk isolator finnas mellan utrustningen och kabel TV n tet In Denmark socket outlets for providing power to No socket outlet provided other equipment shall be in accordance with the Heavy Current Regulations Section 107 2 D1 Standard Sheet DK 1 3a DK 1 5a or DK 1 7a when used on Class equipment For STATIONARY EQUIPMENT the socket outlet shall be in accordance with Standard Sheet DK 1 1b or DK 1 5a For CLASS Il EQUIPMENT the socket outlet shall be in accordance with Standard Sheet DKA 1 4a In Norway for requirements see 1 7 2 1 6 1 2 1 No TNV and 6 1 2 2 of this annex In Finland Norway and Sweden there are No TNV additional requirements for the insulation See 6 1 2 1 and 6 1 2 2 of this annex In Norway for requirements see 1 7 2 1 6 1 2 1 No TNV and 6 1 2 2 of this annex In the United Kingdom the current rating of the circuit shall be taken as 13 A not 16 A N A N A N A N A N A A T VRheinland www tuv com Page 69 of 112 Report No 16041780 001 IEC60950_1B ATTACHMENT National Differences Requirement Test Result Remark Verdict 2 7 1 In the United Kingdom to protect against No direct plug in equipment
43. terminals and accessible parts have a marking stating that the equipment must be connected to an earthed mains socket outlet The marking text in in Finland shall be as follows Laite on liitett v suojakoskettimilla varustettuun pistorasiaan 2 3 2 In Finland there are additional requirements for Should be evaluated during N A the insulation See 6 1 2 1 and 6 1 2 2 of this national approval annex 2 10 5 13 In Finland there are additional requirements for Should be evaluated during N A the insulation see 6 1 2 1 and 6 1 2 2 of this national approval annex A T VRheinland www tuv com Page 77 of 112 Report No 16041780 001 IEC60950_1B ATTACHMENT National Differences Clause Requirement Test Result Remark Verdict 5 1 7 1 In Finland TOUCH CURRENT measurement Not such equipment N A results exceeding 3 5 mA r m s are permitted only for the following equipment STATIONARY PLUGGABLE EQUIPMENT TYPE A that is intended to be used in a RESTRICTED ACCESS LOCATION where equipotential bonding has been applied for example in a telecommunication centre and has provision for a permanently connected PROTECTIVE EARTHING CONDUCTOR and is provided with instructions for the installation of that conductor by a SERVICE PERSON STATIONARY PLUGGABLE EQUIPMENT TYPE B STATIONARY PERMANENTLY CONNECTED EQUIPMENT In Finland add the following text between the Not such equipment N A fi
44. to have a battery disconnect means that may be connected to the computer room remote power off circuit The maximum quantity of flammable liquid No flammable liquid stored stored in equipment is required to comply with NFPA 30 4 3 13 5 Equipment with lasers is required to meet the No laser Code of Federal Regulations 21 CFR 1040 US National Differences according to CB Bulletin www tuv com Page 110 of 112 Clause 4 7 For computer room applications automated information storage systems with combustible media greater than 0 76 m 27 cu ft are required to have a provision for connection of either automatic sprinklers or a gaseous agent extinguishing system with an extended discharge For computer room applications enclosures with combustible material measuring greater than 0 9 m 10 sq ft or a single dimension greater than 1 8 m 6 ft are required to have a flame spread rating of 50 or less For other applications enclosures with the same dimensions require a flame spread rating of 200 or less Annex H Equipment that produces ionizing radiation must comply with Federal Regulations 21 CFR 1020 OTHER NATIONAL DIFFERENCES 1 5 1 Some components and materials associated with the risk of fire electric shock or personal injury are required to have component or material ratings in accordance with the applicable national U S and Canadian component or material requirements These components
45. voltages Multiple power sources Only one supply connection N A provided 3 5 Interconnection of equipment P 3 5 1 General requirements This power supply is not P considered for connection to TNV 3 5 2 Types of interconnection circuits E Interconnection circuits of P SELV through the connector No ELV interconnection circuits 3 5 3 ELV circuits as interconnection circuits No ELV interconnection N A 3 5 4 Data ports for additional equipment No such ports N A PHYSICAL REQUIREMENTS 4 1 Stability Angle of 10 Built in equipment Testiforce M unde aeae e epee aida beet 4 2 Mechanical strength P 4 2 1 General Evaluated for the front panel P side of unit only After tests the parts of unit complies with the requirements of sub clause 2 1 1 2 6 1 and 2 10 However the equipment is for building in compliance have to evaluated in the final system Rack mounted equipment N A 4 2 2 Steady force test 10 N 10 N applied to all P components other than enclosure 4 2 3 Steady force test 30 N 30 N force applied to the P metal chassis of unit no hazards TRF No IEC60950 1B A T VRheinland provided www tuv com Page 25 of 112 Report No 16041780 001 IEC 60950 1 Clause Requirement Test Result Remark Verdict 4 2 4 Steady force test 250 N 250N force applied to the N A metal chassis with inlet s
46. voltages N A 6 1 2 Separation of the telecommunication network from earth N A TRF No IEC60950_1B A TUVRheinland www tuv com Page 31 of 112 Report No 16041780 001 IEC 60950 1 Clause Requirement Test Result Remark Verdict 6 1 2 1 Requirements No TNV N A Supply voltage V Current in the test circuit MA st 6 1 2 2 EXCIUSIONS i ede N A 6 2 Protection of equipment users from overvoltages on telecommunication N A networks 6 2 1 Separation requirements N A 6 2 2 Electric strength test procedure N A 6 2 2 1 Impulse test N A 6 2 2 2 Steady state test N A 6 2 2 3 Compliance criteria N A 6 3 Protection of the telecommunication wiring system from overheating N A Max output current A seeeei Current limiting Method eet 7 CONNECTION TO CABLE DISTRIBUTION SYSTEMS N A 7 1 General Not connected to cable N A distribution system 7 2 Protection of cable distribution system service N A persons and users of other equipment connected to the system from hazardous voltages in the equipment 7 3 Protection of equipment users from overvoltages on N A the cable distribution system 7 4 Insulation between primary circuits and cable N A distribution systems 7 4 1 General N A 7 4 2 Voltage surge test N A 7 4 3 Impulse test N A TRF No IEC60950_1B A TUVRheinland ww
47. 1 Internal creepage distance See table 1 5 1 Distance through insulation See table 1 5 1 Tested under the following conditions See table 1 5 1 Input oo ees Tested with appliance Output otitis Tested with appliance Supplementary information See above table 1 DA 1 6 2 TABLE Electrical data in normal conditions P U V Hz A Irated A P W Fuse Ifuse A Condition status Model WMS 250SFX 103 5 50 5 01 353 8 F1 5 01 Rated load 103 5 60 4 87 351 8 F1 4 87 Rated load 115 50 4 49 5 346 8 F1 4 49 Rated load 115 60 4 38 5 345 5 F1 4 38 Rated load 121 9 50 4 23 344 3 F1 4 23 Rated load 121 9 60 4 14 343 2 F1 4 14 Rated load 126 5 50 4 09 342 8 F1 4 09 Rated load 126 5 60 4 01 341 9 F1 4 01 Rated load 207 50 2 45 334 8 F1 2 45 Rated load 207 60 2 40 334 5 F1 2 40 Rated load 230 50 2 24 5 333 1 F1 2 24 Rated load 230 60 2 20 5 332 8 F1 2 20 Rated load 243 8 50 2 13 332 5 F1 2 13 Rated load 243 8 60 2 09 332 3 F1 2 09 Rated load 253 50 2 07 332 2 F1 2 07 Rated load 253 60 2 03 331 9 F1 2 03 Rated load TRF No IEC60950_1B A TUVRheinland www tuv com Page 46 of 112 Report No 16041780 001 IEC 60950 1 Requirement Test Result Remark Verdict Supplementary information Model WMS 250SFX Maximum normal load 5V 11A 3 3V 12A 12V 12A 12V 0 5A 5Vsb 2A 2 1 1 5 c TABLE max V
48. 10061 CB 1 07 IEC SYSTEM FOR MUTUAL RECOGNITION OF TEST CERTIFICATES FOR ELECTRICAL EQUIPMENT IECEE CB SCHEME Product Produit Name and address of the applicant Nom et adresse du demandeur Name and address of the manufacturer Nom et adresse du fabricant Name and address of the factory Nom et adresse de l usine Rating and principal characteristics Valeurs nominales et caract ristiques principales Trade mark if any Marque de fabrique si elle existe Model type Ref Ref de type Additional information if necessary Information compl mentaire s n cessaire A sample of the product was tested and found to be in conformity with Un chantillon de ce produit a t essay et a t consid r conforme la As shown in the Test Report Ref No which forms part of this Certificate Comme indiqu dans le Rappart d essais num ro de r f rence qui constitue une partie de ce Certificat Ref Certif No JPTUV 045079 SYSTEME CEI D ACCEPTATION MUTUELLE DE CERTIFICATS D ESSAIS DES EQUIPEMENTS ELECTRIQUES IECEE METHODE OC CB TEST CERTIFICATE CERTIFICAT D ESSAI OC Switching Power Supply Winsis inc Shenzhen Biock A Plant Junwei Xin Tongfu Yu Industria Park Zhenmei Rd Guangming New District Shenzhen Guangdong P R China Winsis Inc Shenzhen Block A Plant Junwei Xin Tongiu Yu Industria Park Zhenmei Rd Guangming New District Shenzhen Guangdong P R China
49. 2 A capacitor classified Y3 according to EN 60384 14 2005 may bridge this insulation under the following conditions the insulation requirements are satisfied by having a capacitor classified Y3 as defined by EN 60384 14 2005 which in addition to the Y3 testing is tested with an impulse test of 2 5 kV defined in EN 60950 1 2006 6 2 2 1 the additional testing shall be performed on all the test specimens as described in EN 60384 14 2005 the impulse test of 2 5 kV is to be performed before the endurance test in EN 60384 14 2005 in the sequence of tests as described in EN 60384 14 2005 In Finland the exclusions are applicable for Not such equipment N A PERMANENTLY CONNECTED EQUIPMENT PLUGGABLE EQUIPMENT TYPE B and equipment intended to be used in a RESTRICTED ACCESS LOCATION where equipotential bonding has been applied e g in a telecommunication centre and which has provision for a permanently connected PROTECTIVE EARTHING CONDUCTOR and is provided with instructions for the installation of that conductor by a SERVICE PERSON 6 1 2 2 7 2 In Finland for requirements see 6 1 2 1 and Not such equipment N A 6 1 2 2 of this annex The term TELECOMMUNICATION NETWORK in 6 1 2 being replaced by the term CABLE DISTRIBUTION SYSTEM A TUVRheinland www tuv com Page 79 of 112 Report No 16041780 001 IEC60950_1B ATTACHMENT National Differences Clause Requirement Test Result Remark Ver
50. 53Vac 10min F1 2 07 gt Unit shut down immediately 0 18 except 5Vsb no damage no hazards 253Vac 10min F1 2 07 Unit shut down immediately 0 18 except 5Vsb no damage no hazards 253Vac 10min F1 2 07 gt Unit shut down immediately 0 18 except 5Vsb no damage no hazards 253Vac 10min F1 2 07 gt Unit shut down immediately 0 18 except 5Vsb no damage no hazards 253Vac 10min F1 2 07 gt Unit shut down immediately 0 18 except 5Vsb no damage no hazards 253Vac 10min F1 2 07 gt Unit shut down immediately 0 18 except 5Vsb no damage no hazards 253Vac 10min F1 2 07 gt Unit shut down immediately 0 18 except 5Vsb no damage no hazards 253Vac 10min F1 2 07 Unit shut down immediately no 0 03 damage no hazards 253Vac 10min F1 2 07 Unit shut down immediately no damage no hazards TRF No IEC60950 1B 0 03 A TUVRheinland www tuv com Page 57 of 112 Report No 16041780 001 IEC 60950 1 Requirement Test Result Remark Verdict 253Vac 10min F1 2 07 gt Unit shut down immediately no T2 Pin 5 Pin 7 0 03 damage no hazards T2 Pin 9 253Vac 10min F1 2 07 gt Unit shut down immediately no Pin 10 0 03 damage no hazards 3 3V 253Vac 10min F1 2 07 gt Unit shut down immediately 0 18 except 5Vsb no damage no hazards 12V 253Vac 10min F1 2 07 Unit shut down immediat
51. 60127 1 VDE IEC EN 60127 3 40000505 UL E20624 Alternative Hollyland 50CT T6 3A 250Vac IEC EN 60127 1 VDE IEC EN 60127 3 40014896 UL E156471 Alternative Walter TSC T6 3A 250Vac IEC EN 60127 1 VDE IEC EN 60127 3 40016670 UL E56092 Alternative Walter ICP Series T6 3A 250Vac IEC EN 60127 1 VDE IEC EN 60127 3 40012824 UL E56092 Alternative Conquer UDA A T6 3A 250Vac IEC EN 60127 1 VDE IEC EN 60127 3 40008022 UL E82636 Alternative Conquer PTU T6 3A 250Vac IEC EN 60127 1 VDE IEC EN 60127 3 40001462 UL E82636 X Capacitors Tenta MEX Max IEC EN 60384 14 VDE 119119 CX1 CX2 0 47uF min UL E186475 Optional 250Vac min 85 C X2 type Alternative Ultra Tech Xiphi HQX Max IEC EN 60384 14 VDE40015608 0 47uF min UL E183780 250Vac min 85 C X2 type Alternative Cheng Tung CTX Max IEC EN 60384 14 UL 0 47uF min VDE116941 250Vac min 85 UL E193049 C X2 type Alternative Europtronic MPX Max IEC EN 60384 14 VDE40018238 0 47uF min UL E211347 250Vac min 85 C X2 type TRF No IEC60950_1B A TUVRheinland Page 41 of 112 Report No 16041780 001 IEC 60950 1 www tuv com Requirement Test Result Remark Verdict Alternative Strong MPX Max IEC EN 60384 14 VDE40005451 0 47yF min UL E230903 250Vac min 85 C X2 type Alternative Shenzhen MPX MKP Max IEC EN 60384 14 VDE Yimanfeng 0 47uF min 40028516 UL
52. 7 376 Maximum Vrms T2 Pin 6 T2 Pin 2 222 404 T2 Pin 6 T2 Pin 4 226 428 Maximum Vpeak T2 Pin 7 T2 Pin 2 212 376 T2 Pin 7 T2 Pin 4 226 388 T2 Pin 9 T2 Pin 2 212 376 T2 Pin 9 T2 Pin 4 226 388 T2 Pin 10 T2 Pin 2 207 368 T2 Pin 10 T2 Pin 4 210 372 U2 Pin 1 U2 Pin 3 226 384 U2 Pin 1 U2 Pin 4 226 378 U2 Pin 2 U2 Pin 3 225 380 U2 Pin 2 U2 Pin 4 226 380 A TUVRheinland www tuv com Page 49 of 112 Report No 16041780 001 IEC 60950 1 Requirement Test Result Remark Verdict U01 Pin 1 U01 Pin 3 226 372 U01 Pin 1 U01 Pin 4 226 374 U01 Pin 2 U01 Pin 3 226 374 U01 Pin 2 U01 Pin 4 224 380 U02 Pin 1 U02 Pin 3 223 376 U02 Pin 1 U02 Pin 4 225 376 U02 Pin 2 U02 Pin 3 226 374 U02 Pin 2 U02 Pin 4 223 372 Supplementary information Test voltage 230 V Test frequency 60 Hz 2 10 3and TABLE Clearance and creepage distance measurements P 2 10 4 Clearance cl and creepage U peak Ur m s Required cl cl Required cr cr distance cr at of between V V mm mm mm mm Functional L to N before fuse F1 420 250 15 2 1 L to N under fuse F1 420 250 15 4 0 Basic supplementary Primary components with 420 250 2 0 See 2 5 See 10N to earth below below Heatsink HS1 to secondary 6 0 component C20 surface Primary trace of L N to earth 4 0 4 0 screw Reinforced TRF No IEC60950_1B
53. 80 001 IEC60950 1B ATTACHMENT National Differences Result Remark Verdict 3 2 1 1 In Denmark supply cords of single phase For appliance inlet appliance equipment having a rated current not should be considered during exceeding13 A shall be provided with a plug national approval according to the Heavy Current Regulations Section 107 2 D1 CLASS EQUIPMENT provided with socket outlets with earth contacts or which are intended to be used in locations where protection against indirect contact is required according to the wiring rules shall be provided with a plug in accordance with standard sheet DK 2 1a or DK 2 5a If poly phase equipment and single phase equipment having a RATED CURRENT exceeding 13 A is provided with a supply cord with a plug this plug shall be in accordance with the Heavy Current Regulations Section 107 2 D1 or EN 60309 2 N A 3 2 1 1 3 2 1 1 In Spain supply cords of single phase equipment For appliance inlet appliance having a rated current not exceeding 10 A shall be should be considered during provided with a plug according to UNE national approval 20315 1994 Supply cords of single phase equipment having a rated current not exceeding 2 5 A shall be provided with a plug according to UNE EN 50075 1993 CLASS EQUIPMENT provided with socket outlets with earth contacts or which are intended to be used in locations where protection against indirect contact is
54. A VA test P 1 Voltage rated Current rated Voltage max Current max VA max V A V A VA Model WMS 250SFX Supplementary information Test voltage 253 V Test frequency 60Hz TABLE stored energy N A 2 1 1 5 c 2 Energy E J supplementary information 2 1 1 7 TABLE Discharge test P T measured Comments s Condition T calculated s System on switch Vo 360V on 37 V0 133 2 V Vtc 68 0 V Note s 1 Overall capacity 0 94uF CX1 0 47uF CX2 0 47uF Discharge resistor 0 68Mohm R1 0 68Mohm TABLE evaluation of voltage limiting components in SELV circuits Component measured between max voltage V Voltage Limiting Components normal operation TRF No IEC60950 1B A TUVRheinland www tuv com Page 47 of 112 Report No 16041780 001 IEC 60950 1 Requirement Test Result Remark Verdict Model WMS 250SFX V peak V d c Output terminal 12V Output terminal 12V Output terminal 5V Supplementary information Test voltage 253 V Test frequency 60 Hz Ti Pin 9 to Pin 7 8 amp o L After C12 to Pin 7 8 l oe ur ums E After DB1 to Pin 7 8 79 2 spin After L2 to Pin 7 8 eso l2 Pin 11 12 to Pin 7 8 280 ww Te T2 Pin 2 to Pin 4 og L Fault test performed on voltage limiting components Voltage measured V in SELV circ
55. A TUVRheinland www tuv com Page 50 of 112 Report No 16041780 001 IEC 60950 1 Clause Requirement Test Result Remark Verdict Primary components with 420 250 4 0 See 10N to secondary below Sed components Primary trace of F1 to 4 2 secondary trace under U02 5 1 5 1 under U2 5 3 5 3 under R6 trace to D4 trace 420 250 4 0 4 1 Supplementary information Functional insulation shorted see 5 3 4 a Other functional insulation evaluated according to sub clause 5 3 4 c All internal wires were fixed by soldering and glued The component CY3 fixed by glue for away from metal enclosure Two layers insulation covered the heatsink SH1 A layer of mylar sheet was used bottom and side of the power board Clearance and creepage not described above are far larger than limit above Coro Oo SOYo er AGO os m For mains transformers see appended table C 2 TABLE Distance through insulation measurements Distance through insulation DTI at of U rms Test volt Required DTI mm Opto coupler Supplementary information 1 See appended table 1 5 1 2 Test voltages are a c 4 3 8 TABLE Batteries N A The tests of 4 3 8 are applicable only when appropriate battery data is not available Is it possible to install the battery in a reverse polarity position Rechargeable batteries Charging Discharging Non recharg
56. DE 200W IEC EN 60127 3 40013521 UL E10480 Alternative Littelfuse 677 T5 0A 250Vac IEC EN 60127 1 VDE IEC EN 60127 3 40006258 UL E10480 Alternative Littelfuse 218 Series T5 0A 250Vac IEC EN 60127 1 VDE IEC EN 60127 2 40013496 UL E10480 Alternative Bel Fuse 5HTP T5 0A 250Vac IEC EN 60127 1 VDE IEC EN 60127 3 40000505 UL E20624 Alternative Hollyland 50CT T5 0A 250Vac IEC EN 60127 1 VDE IEC EN 60127 3 40014896 UL E156471 Alternative Walter TSC T5 0A 250Vac IEC EN 60127 1 VDE IEC EN 60127 3 40016670 UL E56092 Alternative Walter ICP Series T5 0A 250Vac IEC EN 60127 1 VDE IEC EN 60127 3 40012824 UL E56092 Alternative Conquer UDA A T5 0A 250Vac IEC EN 60127 1 VDE IEC EN 60127 3 40008022 UL E82636 TRF No IEC60950_1B A TUVRheinland www tuv com Page 40 of 112 Report No 16041780 001 IEC 60950 1 Requirement Test Result Remark Verdict Alternative Conquer PTU T5 0A 250Vac IEC EN 60127 1 VDE IEC EN 60127 3 40001462 UL E82636 Fuse F1 for Littelfuse 215 T6 3A 250Vac IEC EN 60127 1 VDE 250W IEC EN 60127 3 40013521 UL E10480 Alternative Littelfuse 677 T6 3A 250Vac IEC EN 60127 1 VDE IEC EN 60127 3 40006258 UL E10480 Alternative Littelfuse 218 Series T6 3A 250Vac IEC EN 60127 1 VDE IEC EN 60127 2 40013496 UL E10480 Alternative Bel Fuse 5HTP T6 3A 250Vac IEC EN
57. EN 50332 1 Sound system equipment Headphones and earphones associated with portable audio equipment Maximum sound pressure level measurement methodology and limit considerations Part 1 General method for one package equipment and in EN 50332 2 Sound system equipment Headphones and earphones associated with portable audio equipment Maximum sound pressure level measurement methodology and limit considerations Part 2 Guidelines to associate sets with headphones coming from different manufacturers Add the following NOTE NOTE Z1 The use of certain substances in electrical and electronic equipment is restricted within the EU see Directive 2002 95 EC In addition fora PORTABLE SOUND SYSTEM the instructions shall include a warning that excessive sound pressure from earphones and headphones can cause hearing loss Replace the subclause as follows Basic requirements To protect against excessive current short circuits and earth faults in PRIMARY CIRCUITS protective devices shall be included either as integral parts of the equipment or as parts of the building installation subject to the following a b and c a except as detailed in b and c protective devices necessary to comply with the requirements of 5 3 shall be included as parts of the equipment b for components in series with the mains input to the equipment such as the supply cord appliance coupler r f i filter and switch short circuit a
58. Enclosed and sealed parts No hermetically sealed N A component 3 WIRING CONNECTIONS AND SUPPLY 3 1 General 3 1 1 Current rating and overcurrent protection All internal wires are UL recognized wiring which is PVC insulated rated VW 1 min 80 C 300 V the wiring gauge is suitable for current intended to be carried Internal wiring for primary power distribution protected by built in fuse Protection against mechanical damage Wires do not touch sharp P edges which could damage the insulation and cause hazard Securing of internal wiring The wires are secured by P soldering and glue on PCB so that a loosening of the terminal connection is unlikely Insulation of conductors The insulation of the individual P conductors is suitable for the application and the working voltage For the insulation material see 3 1 1 Beads and ceramic insulators Not used N A Screws for electrical contact pressure No such screws provided N A 3 1 7 Insulating materials in electrical connections All current carrying P connections are metal to metal Self tapping and spaced thread screws Not used N A 3 1 9 Termination of conductors All conductors are reliable P secured 10 N pull test Force of 10 N applied to the P termination points of the conductors 3 1 10 Sleeving on wiring N A TRF No IEC60950 1B www tuv com Page 22 of 112 Clause IEC 60950 1 Requirement Test Result Remark A TUVRheinland Report No
59. For appliance inlet appliance should be considered during national approval For appliance inlet appliance should be considered during national approval N A N A N A N A N A N A www tuv com 5 1 7 1 6 1 2 1 A1 2010 Page 72 of 112 In Finland Norway and Sweden TOUCH CURRENT measurement results exceeding 3 5 mA r m s are permitted only for the following equipment STATIONARY PLUGGABLE EQUIPMENT TYPE A that is intended to be used in a RESTRICTED ACCESS LOCATION where equipotential bonding has been applied for example in a telecommunication centre and has provision for a permanently connected PROTECTIVE EARTHING CONDUCTOR and is provided with instructions for the installation of that conductor by a SERVICE PERSON STATIONARY PLUGGABLE EQUIPMENT TYPE B STATIONARY PERMANENTLY CONNECTED EQUIPMENT In Finland Norway and Sweden add the following text between the first and second paragraph of the compliance clause If this insulation is solid including insulation forming part of a component it shall at least consist of either two layers of thin sheet material each of which shall pass the electric strength test below or one layer having a distance through insulation of at least 0 4 mm which shall pass the electric strength test below Alternatively for components there is no distance through insulation requirements for the insulation consisting of an
60. Industrial Park Zhenmei Rd Guangming New District Shenzhen P R China Manufacturer s name Same as applicant Address ee aaa Same as applicant Test specification Standard ceteris IEC 60950 1 2005 2nd Edition Am 1 2009 Test procedure suuss CB Scheme Non standard test method N A Test Report Form No EC60950 1B Test Report Form s Originator SGS Fimko Ltd Master TRF ceu Dated 2010 04 Copyright 2010 Worldwide System for Conformity Testing and Certification of Electrotechnical Equipment and Components IECEE Geneva Switzerland All rights reserved This publication may be reproduced in whole or in part for non commercial purposes as long as the IECEE is acknowledged as copyright owner and source of the material IECEE takes no responsibility for and will not assume liability for damages resulting from the reader s interpretation of the reproduced material due to its placement and context If this Test Report Form is used by non IECEE members the IECEE IEC logo and the reference to the CB Scheme procedure shall be removed This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02 Test item description Switching Power Supply Trade Mark sess bii Ma
61. RDS P 2 1 Protection from electric shock and energy hazards P 2 1 1 Protection in operator access areas No access with test finger and test pin to any parts with only basic insulation to ELV or hazardous voltage 2 1 1 1 Access to energized parts P Test by InSpectlon s 8 ieee Lieb tectis i P Test with test finger Figure 2A P Test with test pin Figure 2B P Test with test probe Figure 2C No TNV N A TRF No IEC60950 1B www tuv com Page 13 of 112 A T VRheinland Report No 16041780 001 IEC 60950 1 Clause Requirement Test Result Remark Verdict 2 1 1 2 Battery compartments No battery compartment N A 2 1 1 3 Access to ELV wiring No ELV wiring in operator N A accessible area Working voltage Vpeak or Vrms minimum distance see appended tables 2 10 2 through insulation mm and 2 10 5 2 1 1 4 Access to hazardous voltage circuit wiring No hazardous voltage wiring in N A operator accessible area 2 1 1 5 Energy hazards epit Energy does not exceed P 240VA between any two points in accessible parts o p connector of secondary circuit Results see appended table 2 1 1 5 No energy hazard in operator access area See appended table for reference 2 1 1 6 Manual controls No manual controls N A 2 1 1 7 Discharge of capacitors in equipment No risk of electric shock see P below Measured voltage
62. UALIFIED PERSONNEL WARRANTY VOID IF SEAL REMOVED OR DAMAGED SIN WK081102P MADE IN CHINA TRF No IEC60950 1B A T VRheinland www tuv com Page 6 of 112 Report No 16041780 001 Test item particulars sssssssssssst Equipment mobility sse EI movable J hand held O transportable stationary X for building in direct plug in pluggable equipment X type A type B permanent connection detachable power supply cord non detachable power supply cord not directly connected to the mains continuous rated operating resting time Connection to the mains eel Operating condition sssssssesses T Access location RR edt operator accessible restricted access location OVCI X ovc Il L OVC Ill L OVC IV L other Mains supply tolerance or absolute mains supply 10 10 as client s request MET E rite ele 1 ORO OOO O Over voltage category OVC ssssssss i Tested for IT power systems st DX Yes L No IT testing phase phase voltage V N A Class of equipment sssssssseee DQ Class C Class II Class III LI Not classified Considered current rating of protective device as part 16 or 20 for North America of the building installlation A t Pollution degree PD
63. UIPMENT and earthed circuits in CLASS II EQUIPMENT Class N A Annex JA Add Annex JA Document shredding machines Document shredding machines shall also comply with the requirements of this annex except those of STATIONARY EQUIPMENT used by connecting directly to an AC MAINS SUPPLY of three phase 200V or more Added Not Document shredding machines N A JA 1 Markings and instructions In the easily visible part near the document slot by a method capable to make out clearly and not easily disappeared and by easily understandable wording shall indicate the symbol of A and also the following precautions for use that use by an infant child may cause a hazard of injury etc that a hand can be drawn into the mechanical section for shredding when touching the document slot Added Not Document shredding machines N A Japanese Deviations for J60950 1 H22 2009 MITI Ordinance Clause 2 www tuv co m Page 104 of 112 A T VRheinland Report No 16041780 001 Clause JA 2 IEC60950 1B ATTACHMENT National Differences Requirement Test Result Remark Verdict that clothes can be drawn into the mechanical section for shredding when touching the document slot that hairs can be drawn into the mechanical section for shredding when touching the document slot in case of equipment incorporating a commutator motor that equipment may catch fire or explode by spra
64. ad After L7 o l 253Vac 4 0hrs F1 0 18 gt Temperature was stable at 1 9A T2 Pin 0 23 gt increase to 2 1A unit shut down 4 5Vsb 0 28 gt immediately Maximum transformer 0 03 temperature was T1 coil overload 39 4 C T1 core 38 3 C T2 coil 125 7 C T2 core 119 0 C Ambient 26 9 C no damage no hazards Output with normal load TRF No IEC60950 1B www tuv com Page 59 of 112 A T VRheinland Report No 16041780 001 IEC 60950 1 Requirement Test Result Remark Verdict TRF No IEC60950 1B 3 3V o 253Vac 3 0hrs F1 2 07 Temperature was stable at 2 20 17 6A increase to 18 6A unit 2 25 shut down except 5Vsb 0 18 Maximum temperature was T1 coil 89 8 C T1 core 88 0 C T2 coil 84 3 C T2 core 83 6 C Ambient 27 2 C no damage no hazards 5V o 253Vac 3 0hrs F1 2 07 Temperature was stable at 16A 2 22 increase to 17 2A unit shut 2 30 down except 5Vsb Maximum 0 18 temperature was T1 coil 95 2 C T1 core 94 5 C T2 coil 80 9 C T2 core 78 1 C Ambient 27 2 C no damage no hazards 12V o 253Vac 4 0hrs F1 2 07 Temperature was stable at 16A 2 26 increase to 17 8A unit shut 2 45 down except 5Vsb Maximum 0 18 temperature was T1 coil 95 3 C T1 core 93 3 C T2 coil 84 5 C T2 core 83 0 C Ambient 26 9 C No damage no hazards 12V o l 253Vac 3 0hrs F1 2 07 Temperature was s
65. an fall onto an external surface underneath the equipment the equipment is considered to have failed to meet the requirement of clause 4 7 201 without the need for consequential testing NOTE 3 Parts likely to be impinged upon by the flame are considered to be those within the envelope of a vertical cylinder having a radius of 10 mm and a height equal to the height of the flame positioned above the point of the material supporting in contact with or in close proximity to connections Australian National Differences according to CB Bulletin A TUVRheinland www tuv com Page 86 of 112 Report No 16041780 001 IEC60950 1B ATTACHMENT National Differences Clause Requirement Test Result Remark Verdict 4 7 201 5 Testing of printed boards Added N A The base material of printed boards is subjected to needle flame test to Clause 4 7 201 3 The flame is applied to the edge of the board where the heat sink effect is lowest when the board is positioned as in normal use The flame shall not be applied to an edge consisting of broken perforations unless the edge is less than 3 mm for a potential ignition Source The test is not carried out if the Printed board does not carry any potential ignition Source Base material of printed boards on which the available apparent power at a connection exceeds 15 VA operating at a voltage exceeding 50 V and equal or less than 400 V peak a c or d c under normal op
66. ased on requirements other than national regulatory requirements 1 5 1 Some components and materials associated with Shall be evaluated during N A the risk of fire electric shock or personal injury are national approval Others see required to have component or material ratings in IEC 60950 1 test report for accordance with the applicable national Canadian further details and or U S component or material standard requirements These components include attachment plugs battery packs rechargeable type used with transportable equipment cathode ray tubes circuit breakers communication circuit accessories connectors used for current interruption of non LPS circuits cord sets and power supply cords direct plug in equipment enclosures outdoor flexible cords and cables fuses branch circuit fuseholders ground fault current interrupters industrial control equipment insulating tape interconnecting cables lampholders limit controls printed wiring protectors for communications circuits receptacles solid state controls supplementary protectors switches including interlock switches thermal cutoffs thermostats multi layer transformer winding wire transient voltage surge suppressors tubing wire connectors and wire and cables 1 6 1 2 A circuit for connection to the DC Mains Supply is No such circuit N A classified as either a SELV Circuit TNV 2 Circuit or Hazardous Voltage Circuit depending
67. ccessible unless it is not interchangeable Suitable NEC branch circuit protection rated at the maximum circuit rating is required for all standard supply outlets and receptacles such as supplied in power distribution units if the supply branch circuit protection is not suitable Power distribution transformers distributing power at 100 volts or more and rated 10 kVA or more require special transformer overcurrent protection the connection of the equipment to the mains shall be in accordance with the NEC Wiring methods terminals leads etc used for Single phase No fuse used for LPS No such device 3 2 1 Power supply cords are required to have attachment plugs rated not less than 125 percent of the rated current of the equipment Appliance inlet used No power N A supply cords provided and should be evaluated during national approval US National Differences according to CB Bulletin A T VRheinland www tuv com Page 109 of 112 Report No 16041780 001 IEC60950 1B ATTACHMENT National Differences Requirement Test Result Remark Equipment connected to a centralized d c power system and having one pole of the DC mains input terminal connected to the main protective earthing terminal in the equipment is required to comply with special earthing wiring marking and installation instruction requirements Verdict Permanent connection of equipment to the Not permanen
68. ccording to CB Bulletin Not such equipment No such terminals provided N A N A A TUVRheinland www tuv com Page 91 of 112 Report No 16041780 001 IEC60950 1B ATTACHMENT National Differences Clause Requirement Test Result Remark Verdict 3 3 3 Wire binding screws are not permitted to attach No such screws provided N A conductors larger than 10 AWG 5 3 mm 3 3 4 Terminals for permanent wiring including No such terminals provided N A protective earthing terminals are required to be suitable for Canadian US wire gauge sizes rated 125 percent of the equipment rating and be specially marked when specified 1 7 7 3 4 2 Motor control devices are required for Equipment is not such a N A cord connected equipment with a motor if the device equipment is rated more than 12 A or if the motor has a nominal voltage rating greater than 120 V or is rated more than 1 3 hp locked rotor current over 43 A 3 4 8 Vertically mounted disconnect switches and circuit No such devices incorporated N A breakers are required to have the on position indicated by the handle in the up position 3 4 11 For computer room applications equipment with Not such an application N A battery systems capable of supplying 750 VA for five minutes are required to have a battery disconnect means that may be connected to the computer room remote power off circuit 4 3 12 The maximum quantity of flammable liquid stored
69. communication ports N A b EUT whose telecommunication ports have no N A reference to protective earth 5 2 Electric strength 5 2 1 General see appended table 5 2 5 2 2 Test procedure see appended table 5 2 P 5 3 Abnormal operating and fault conditions P 5 3 1 Protection against overload and abnormal operation Output overload test the most unfavorable load test see appended table 5 3 5 3 2 Motors Approved DC fan used N A 5 3 3 Transformers With the shorted o p of the P transformer no high temperature of the transformer was recorded Results of the short circuit tests see appended table 5 3 and Annex C 5 3 4 Functional insulation Method c Test results see P appended table 5 3 5 3 5 Electromechanical components No electromechanical N A component provided 5 3 6 Audio amplifiers in ITE sessen No such component N A 5 3 7 Simulation of faults Results see appended table P 5 3 8 Unattended equipment None of the listed components N A was provided 5 3 9 Compliance criteria for abnormal operating and fault No fire propagated beyond the P conditions equipment No molten metal was emitted Electric strength test primary to SELV was passed 5 3 9 1 During the tests P 5 3 9 2 After the tests P 6 CONNECTION TO TELECOMMUNICATION NETWORKS N A 6 1 Protection of telecommunication network service persons and users of other N A equipment connected to the network from hazards in the equipment 6 1 1 Protection from hazardous
70. ctions Provide an earthing connection before the mains plug is connected to the mains And when disconnecting the earthing connection be sure to disconnect after pulling out the mains plug from the mains 2 6 3 2 Add the following after 1st paragraph Appliance inlet used N A This also applies to the conductor of lead wire for protective earthing of CLASS 0l EQUIPMENT 2 6 4 2 Replace 1st paragraph with the following Appliance inlet used Equipment required to have protective earthing shall have a main protective earthing terminal For equipment with a DETACHABLE POWER SUPPLY CORD the earthing terminal in the appliance inlet is regarded as the main protective earthing terminal except for CLASS 0I EQUIPMENT providing separate main protective earthing terminal other than appliance inlet 2 6 5 4 Replace 1st sentence with the following Protective earthing connections of CLASS EQUIPMENT shall make earlier and break later than the supply connections in each of the following Japanese Deviations for J60950 1 H22 2009 MITI Ordinance Clause 2 A T VRheinland www tuv com Page 101 of 112 Report No 16041780 001 IEC60950 1B ATTACHMENT National Differences Clause Requirement Test Result Remark Verdict 2 6 5 8A Add the following new clause after 2 6 5 8A Appliance inlet used N A 2 6 5 8A Earthing of CLASS 01 EQUIPMENT Plugs with a lead wire for earthing shall not be used for equipm
71. d parapgaph with the following Should be considered during N A 3 national approval manufacturer s or responsible company s name or trade mark or identification mark Japanese Deviations for J60950 1 H22 2009 MITI Ordinance Clause 2 A T VRheinland www tuv com Page 100 of 112 Report No 16041780 001 IEC60950 1B ATTACHMENT National Differences Clause Requirement Test Result Remark Verdict 1 7 5 A Add the following new clause after 1 7 5 N A 1 7 5A Appliance Coupler If appliance coupler according to IEC60320 1 C 14 rated current 10A is used in equipment whose rated voltage is less than 125V and rated current is over 10A the following instruction or equivalent shall be described in the user instruction Use only designated cord set attached in this equipment 1 7 12 Replace first sentence with the following Should be evaluated during N A Instructions and equipment marking related to national approval safety shall be in Japanese 1 7 17A Add the following new clause after 1 7 17 Appliance inlet used 1 7 17A Marking for CLASS 01 EQUIPMENT For CLASS 0l EQUIPMENT the following instruction shall be marked on the visible place of the mains plug or the main body N A Provide an earthing connection Moreover for CLASS 0l EQUIPMENT the following or equivalent instruction shall be indicated on the visible place of the main body or written in the operating instru
72. dd the following after clause 4 7 3 6 Added P 4 7 201 Resistance to fire Alternative tests Australian National Differences according to CB Bulletin A TUVRheinland www tuv com Page 83 of 112 Report No 16041780 001 IEC60950 1B ATTACHMENT National Differences Clause Requirement Test Result Remark Verdict 4 7 201 1 General PCB bobbin P Parts of non metallic material shall be resistant to ignition and spread of fire This requirement does not apply to decorative trims knobs and other parts unlikely to be ignited or to propagate flames originating from inside the apparatus or the following Components that are contained in an enclosure having a flammability category of FV 0 according to AS NSZ 4695 707 and having openings only for the connecting wires filling the openings completely and for the ventilation not exceeding 1 mm in width regardless of the length The following parts which would contribute negligible fuel to a fire small mechanical parts the mass of which does not exceed 4 g such as mounting parts gears cams belts and bearings small electrical components such as capacitors with a volume not exceeding 1750 mm3 integrated circuits transistors and optocoupler packages if these components are mounted on material flammability category FV 1 or better according to AS NZS 4695 707 NOTE In considering how to minimize propagation of fire and what small parts are account
73. dict ATTACHMENT TO TEST REPORT IEC 60950 1 FINLAND NATIONAL DIFFERENCES Information technology equipment Safety PART 1 GENERAL REQUIREMENTS Differences according to EN 60950 1 2006 A12 2011 Attachment Form No n Attachment Originator MEO Master Attachment S s Copyright 2010 IEC System for Conformity Testing and Certification of Electrical Equipment IECEE Geneva Switzerland All rights reserved National Differences P 1 3 21 Delete the addition of 1 3 21 Delete N A 1 2 3 Delete the definition 1 2 3 21 Delete N A 1 7 2 1 Delete NOTE Z1 and the addition for Portable Delete N A Sound System a Add the following clause and annex to the Added N A existing standard and amendments No such equipment Zx Protection against excessive sound pressure from personal music players Zx 1 A personal music player and earphones or N A headphones intended to be used with personal music players shall comply with the requirements of this sub clause The requirements in this sub clause are valid for music or video mode only The requirements do not apply while the personal music player is connected to an external amplifier or while the headphones or earphones are not used The requirements do not apply to hearing aid equipment and professional equipment analogue personal music players personal music players
74. ding components providing safety isolation ClassB Tmax 120 C 10 C 110 C 10 C decreased by thermocouple method Operator touchable surface with maximum temperature rise of 70 C For the other non listed component temperature limit refer to table 1 5 1 Test condition a 103 5V 50Hz rated load b 126 5V 50Hz rated load c 207V 50Hz rated load d 253V 50Hz rated load e 103 5V 50Hz stand by TABLE Ball pressure test of thermoplastic parts N A Allowed impression diameter mm lt 2 mm Test temperature Impression diameter mm Supplementary information The bobbin material of transformer T1 amp T2 is phenolic no test is needed TABLE Resistance to fire Manufacturer of Type of material Thickness Flammability Evidence material Supplementary information 5 1 TABLE touch current measurement Measured between Measured Limit Comments conditions E eed L N Enclosure ose 68 3 5 System ON switch e opened ON switch e opened Output terminals 0 68 3 5 System ON switch e opened TRF No IEC60950_1B www tuv com Page 54 of 112 A TUVRheinland Report No 16041780 001 IEC 60950 1 Requirement Test Result Remark Verdict supplementary information Test voltage 253Vac Test frequency 60Hz Capacitance CY1 CY2 CY3 4700pF
75. ds switch Model WMS 250SFX BD1 S C 253Vac 1sec F1 Fuse open immediately no hazards C1 S C 253Vac 1sec F1 Fuse open immediately no hazards C2 S C 253Vac 1sec F1 Fuse open immediately no hazards R22 S C 253Vac 1sec F1 Fuse open immediately Q2 damage no hazards U1 Pin 7 8 s c 253Vac 1sec F1 Fuse open immediately no Pin 5 hazards U1 Pin 7 8 s c 253Vac 1sec F1 Fuse open immediately no Pin 3 hazards R8 S C 253Vac 1sec F1 Fuse open immediately no hazards Voltage Voltage 126 5 1sec F1 Fuse open immediately no select mismatch Vac gt hazards switch In fault column where s c short circuited o I over loaded o c open circuited a For fuse opened condition same result came out for each source of fuse used and the fuse dose not A TUVRheinland www tuv com Page 61 of 112 Report No 16041780 001 IEC 60950 1 Requirement Test Result Remark Verdict C 2 TABLE transformers T1 P Loc Tested insulation Working Working Required Required Required Required voltage voltage electric clearance creepage distance peak V rms V strength mm distance thr insul mm 2 10 2 2 10 2 5 2 2 10 3 2 10 4 2 10 5 Primary RI 480 250 3000Vac 4 2 5 0 0 4 winding to secondary winding Core to BI 480 250 1707Vac 2 1 2 5 Primary winding Core to SI 480 250 1707Vac 2 1 2 5 0 4 secondary winding Loc Tested
76. e s sssssst Sample 3 burning time S ssssst A 2 7 Alternative test acc to IEC 60695 11 5 cl 5 and 9 N A Sample 1 burning time s ssssst Sample 2 burning time s sssssst Sample 3 burning time s ssssst A 3 Hot flaming oil test see 4 6 2 N A A 3 1 Mounting of samples NAA A 3 2 Test procedure N A TRF No IEC60950 1B A TUVRheinland www tuv com Page 33 of 112 Report No 16041780 001 IEC 60950 1 Requirement Test Result Remark Verdict A 3 3 Compliance criterion N A B ANNEX B MOTOR TESTS UNDER ABNORMAL CONDITIONS see 4 7 2 2 and N A 5 3 2 B 1 General requirements Approved DC fan used N A B 2 Test conditions N A B 3 Maximum temperatures N A B 4 Running overload test N A B 5 Locked rotor overload test N A Test duration days Electric strength test test voltage V i B 6 Running overload test for d c motors in secondary N A circuits B 6 1 General N A B 6 2 Test procedure N A B 6 4 Electric strength test test voltage V N A bed secondary circuits B 7 4 Electric strength test test voltage V N A Operating voltage V See appended table 1 5 1 Z See appended table 1 5 1 TRF No IEC60950_1B A TUVRheinland
77. e N A M 3 2 3 Monitoring voltage V esent N A N ANNEX N IMPULSE TEST GENERATORS see 1 5 7 2 1 5 7 3 2 10 3 9 6 2 2 1 N A 7 3 2 7 4 3 and Clause G 5 N 1 ITU T impulse test generators N A N 2 IEC 60065 impulse test generator N A P ANNEX P NORMATIVE REFERENCES ANNEX Q Voltage dependent resistors VDRs see 1 5 9 1 N A No VDR used N A N A N A R ANNEX R EXAMPLES OF REQUIREMENTS FOR QUALITY CONTROL N A PROGRAMMES R 1 Minimum separation distances for unpopulated N A coated printed boards see 2 10 6 2 R 2 Reduced clearances see 2 10 3 N A S ANNEX S PROCEDURE FOR IMPULSE TESTING see 6 2 2 3 N A S 1 Test equipment N A 2 Test procedure N A 3 Examples of waveforms during impulse testing N A TRF No IEC60950_1B www tuv com A TUVRheinland Report No 16041780 001 Page 37 of 112 IEC 60950 1 Requirement Test Result Remark Verdict T ANNEX T GUIDANCE ON PROTECTION AGAINST INGRESS OF WATER N A see 1 1 2 U ANNEX U INSULATED WINDING WIRES FOR USE WITHOUT INTERLEAVED N A INSULATION see 2 10 5 4 V ANNEX V AC POWER DISTRIBUTION SYSTEMS see 1 6 1 P V 1 Introduction P V 2 TN power distribution systems P Ww ANNEX W SUMMATION OF TOUCH CURRENTS N A W 1 Touch current from electronic circuits N A W 1 1 Floating circuits N A W 1 2 Earthed circuits N A W 2 Interconnection of several equipments N A W 2 1 Isolation N A W 2 2 Common ret
78. eable batteries Un intentional Reversed charging Discharging TRF No IEC60950 1B A TUVRheinland www tuv com Page 51 of 112 Report No 16041780 001 IEC 60950 1 Requirement Test Result Remark Verdict Meas Manuf charging Meas Manuf current Specs current Specs Manuf Specs Meas Manuf Meas current Specs current Max current during normal condition Max current during fault condition Test results Verdict Chemical leaks Explosion of the battery Emission of flame or expulsion of molten metal Electric strength tests of equipment after completion of tests Supplementary information 438 TABLE Batteries N A Battery category eese Lithium NiMh NiCad Lithium lon Manufacturer sss Type model t rts Voltages ish eae tte den GGapacilty 5 nef rep te in Monti mAh Tested and Certified by incl Ref No Circuit protection diagram MARKINGS AND INSTRUCTIONS 1 7 12 1 7 15 Location of replaceable battery pip LS See below an LO snum See below TRF No IEC60950 1B www tuv com Page 52 of 112 A TUVRheinland Report No 16041780 001 IEC 60950 1 Requirement Test Result Remark Verdict Ei See below ee Maximum temperature T of T C
79. ecified See model list Observation A TUVRheinland www tuv com Page 55 of 112 Report No 16041780 001 IEC 60950 1 Requirement Test Result Remark Verdict Model WMS 250SFX BD1 S C 253Vac 1sec F1 Fuse open immediately no hazards C1 S C 253Vac 1sec F1 Fuse open immediately no hazards C2 S C 253Vac 1sec F1 Fuse open immediately no hazards Q1 Pin G s c 253Vac 10min F1 2 07 gt Unit shut down immediately Pin S 0 18 except 5Vsb no damage no hazards Q1 Pin G s c 253Vac 10min F1 2 07 gt Unit shut down immediately Pin D 0 18 except 5Vsb no damage no hazards Q1 Pin D s c 253Vac 10min F1 2 07 gt Unit shut down immediately Pin S 0 18 except 5Vsb no damage no hazards Q2 Pin G s c 253Vac 10min F1 2 07 gt Unit shut down immediately Pin S 0 18 except 5Vsb no damage no hazards Q2 Pin G s c 253Vac 10min F1 2 07 gt Unit shut down immediately Pin D 0 18 except 5Vsb no damage no hazards Q2 Pin D s c 253Vac 10min F1 2 07 Unit shut down immediately Pin S 0 18 except 5Vsb no damage no hazards R22 S C 253Vac 1sec F1 Fuse open immediately Q2 damage no hazards U1 Pin 7 8 s c 253Vac 1sec F1 Fuse open immediately no Pin 5 hazards U1 Pin 7 8 s c 253Vac 1sec F1 Fuse open immediately no Pin 3 hazards R8 S C 253Vac 1sec F1 Fuse open immediately no hazards U2 Pin 1 S C 253Vac 10min F1 2
80. ed table 1 5 1 N A No DC mains supply US National Differences according to CB Bulletin A T VRheinland www tuv com Page 111 of 112 Report No 16041780 001 IEC60950 1B ATTACHMENT National Differences Requirement Test Result Remark 2 3 1 For TNV 2 and TNV 3 circuits with other than No TNV ringing signals and with voltages exceeding 42 4 Vpeak or 60 Vd c the max acceptable current through a 2000 ohm resistor or greater connected across the voltage source with other loads disconnected is 7 1 mA peak or 30 mA d c under normal operating conditions Verdict In the event of a single fault between TNV and No TNV SELV circuits the limits of 2 2 3 apply to SELV Circuits and accessible conductive parts Protective bonding conductors of non standard protective bonding constructions e g printed circuit traces may be subjected to the additional limited short circuit test conditions specified 4 2 8 1 Enclosures around CRTs with a face diameter No CRT of 160 mm or more are required to reduce the risk of injury due to the implosion of the CRT 4 2 11 For equipment intended for mounting on racks No such equipment and provided with slide rails allowing the equipment to slide away from the rack for installation service and maintenance additional construction performance and marking requirements are applicable to determine the adequacy of the slide rails Equipment with handles i
81. einland www tuv com Page 26 of 112 Report No 16041780 001 IEC 60950 1 4 3 8 Batteries N A Overcharging of a rechargeable battery EE N A Unintentional charging of a non rechargeable battery S N A Reverse charging of a rechargeable battery Pe N A Excessive discharging rate for any battery a N A 439 Oil and grease N A provided 4 3 10 Dust powders liquids and gases Equipment in intended use not N A considered to be exposed to these 4 3 11 Containers for liquids or gases N A 4 3 12 Flammable liquids N A Quantityofliquid RR WA Flashpoint 20 2 aet ed teer N A 4 3 13 Radiation N A 4 3 13 1 General PN 4 3 13 2 lonizing radiation Po Measured radiation pA kg ssst LC Measured high voltage KV 0 o Measured focus voltage kV suut E CRT Makdee araa a ee oiiaii EE 4 3 13 3 Effect of ultraviolet UV radiation on materials PN Part property retention after test flammability rt N A classification 4 3 13 4 Human exposure to ultraviolet UV radiation ce N A 4 3 13 5 Lasers including laser diodes and LEDs BE N A 4 3 13 5 1 Lasers including laser laser diodes N A Laser class nene eia 4 3 13 5 2 Light emitting diodes LEDs N A 4 3 13 6 Other types eee eeeeseeeeeeeereeeteneseaeseneeeeeerenees N A 4 4 Protection against hazardous moving parts P 4 4 1 General P 4 4 2 Protect
82. el Insulated wiring The fire enclosure is required 4 7 2 2 Parts not requiring a fire enclosure N A 4 7 3 Materials P 4 7 3 1 General Parts mounted on PCB of P flammability class V 1 or better 4 7 3 2 Materials for fire enclosures The metal enclosure P 4 7 3 3 Materials for components and other parts outside fire No part outside fire enclosure N A enclosures 4 7 3 4 Materials for components and other parts inside fire Internal components except P enclosures small parts are V 2 or better 4 7 3 5 Materials for air filter assemblies No air filters provided N A 4 7 3 6 Materials used in high voltage components No high voltage components N A TRF No IEC60950 1B A TUVRheinland www tuv com Page 29 of 112 Report No 16041780 001 IEC 60950 1 Clause Requirement Test Result Remark Verdict 5 ELECTRICAL REQUIREMENTS AND SIMULATED ABNORMAL CONDITIONS P 5 1 Touch current and protective conductor current 5 1 1 General See sub clauses 5 1 2 to 5 1 6 5 1 2 Configuration of equipment under test EUT EUT has only one mains P connection 5 1 2 1 Single connection to an a c mains supply P 5 1 2 2 Redundant multiple connections to an a c mains N A supply 5 1 2 3 Simultaneous multiple connections to an a c mains N A supply 5 1 3 Test circuit Equipment of figure 5A used 5 1 4 Application of measuring instrument Using measuring instrument in annex D 5 1 5 Test procedure The touch current was P measured
83. ely 0 18 except 5Vsb no damage no hazards S C 253Vac 10min F1 2 07 Unit shut down immediately 0 18 except 5Vsb no damage no hazards 12V 253Vac 10min F1 2 07 gt Unit shut down immediately 0 18 except 5Vsb no damage no hazards 5Vsb 253Vac 10min F1 2 07 gt Unit shut down immediately no 0 03 damage no hazards 253Vac 10min F1 4 27 Unit shut down immediately 0 18 except 5Vsb no damage no hazards 253Vac 10min F1 2 07 Unit shut down immediately 0 18 except 5Vsb no damage no hazards 253Vac 10min F1 2 07 Unit shut down immediately 0 18 except 5Vsb no damage no hazards 253Vac 10min F1 2 07 gt Normal operation no damage 2 06 no hazards 5V 12V s c 253Vac 10min F1 2 07 Unit shut down immediately 0 18 except 5Vsb no damage no hazards 45V 12V s c 253Vac 10min F1 2 07 Unit shut down immediately 0 18 except 5Vsb no damage no hazards S C 253Vac 10min F1 2 07 Normal operation no damage 2 08 no hazards 12V 12V s c 253Vac 10min F1 2 07 Unit shut down immediately 0 18 except 5Vsb no damage no hazards S C 253Vac 10min F1 2 07 Unit shut down immediately no 0 03 damage no hazards S C 253Vac 10min F1 2 07 Unit shut down immediately no 0 03 damage no hazards TRF No IEC60950 1B A TUVRheinland www tuv com Page 58 of 112 Report No 16041780 001 IEC 60950 1 Req
84. ent having a rated voltage exceeding 150V For plugs with a lead wire for earthing the lead wire shall not be earthed by a clip CLASS 0l EQUIPMENT shall be provided with an earthing terminal or lead wire for earthing in the external location where easily visible 3 2 3 Add the following after Table 3A Not permanently connected N A Table 3A applies when cables complying JIS C 3662 or JIS C 3663 are used In case of other cables cable entries shall be so designed that a conduit suitable for the cable used can be fitted 3 2 5 1 Add the following to the last of first dashed Applince inlet equipment N A paragraph should be considered during Or mains cords shall be of the sheathed type nanana approval complying with Appendix 1 of Article 1 of the Ministerial Ordinance on stipulating technical requirements for the Electrical Appliance Add the following to the last of second dashed paragraph Or mains cords shall be of the sheathed type complying with Appendix 1 of Article 1 of the Ministerial Ordinance on stipulating technical requirements for the Electrical Appliance Delete 1 in Table 3B 3 3 4 Add the following note to Table 3D Note For cables other than those complying with JIS C 3662 or JIS C 3663 terminals shall be suitable for the size of the intended cables N A 3 3 7 Add the following after the first sentence Class N A This requirement is not applicable to the external earting terminal of Class 0l
85. erating conditions is of flammability category FV 1 or better according to AS NZS 4695 707 or the printed boards are protected by an enclosure meeting the flammability category FV 0 according to AS NZS 4695 707 or made of metal having openings only for connecting wires which fill the opening completely or Base material of printed boards on which the available apparatus power at a connection exceeds 15 VA operating at a voltage exceeding 400 V peak a c or d c under normal operating conditions and base material printed boards supporting spark gaps which provide protection against overvoltages is of flammability category FV 0 according to AS NSZ 4695 707 or the printed boards are contained in a metal enclosure having openings only for connecting wires fill the openings completely Compliance is determined using the smallest thickness of the material NOTE Available apparent power is the maximum apparent power which can be drawn from the supplying circuit through a resistive load whose value is chosen to maximise the apparent power for more than 2 min when the circuit supplied is disconnected 6 2 2 Add the following after the first paragraph No TNV N A In Australia this variation does not apply in New Zealand compliance with 6 2 2 is checked by the tests of both 6 2 2 1 and 6 2 2 2 Delete the note Australian National Differences according to CB Bulletin A TUVRheinland www tuv com Page 87
86. etwork or cable No TNV N A distribution system 2 7 Overcurrent and earth fault protection in primary circuits P 2 7 1 Basic requirements Protection against overcurrents and short circuits is provided as an integral part of the equipment Protection against earth faults is provided as part of the building installation Instructions when protection relies on building Not applicable for pluggable N A installation equipment type A 2 7 2 Faults not simulated in 5 3 7 The protection device is well P dimensioned and mounted TRF No IEC60950 1B www tuv com Page 17 of 112 IEC 60950 1 A T VRheinland Report No 16041780 001 Clause Requirement Test Result Remark Verdict 2 7 3 Short circuit backup protection Pluggable equipment type A Building installation is considered as providing short circuit backup protection 2 7 4 Number and location of protective devices Over current protection by one current fuse 2 7 5 Protection by several devices Only one current fuse 2 7 6 Warning to service personnel No service work necessary 2 8 Safety interlocks N A 2 8 1 General principles No safety interlocks N A 2 8 2 Protection requirements N A 2 8 3 Inadvertent reactivation N A 2 8 4 Fail safe operation N A Protection against extreme hazard N A 2 8 5 Moving parts N A 2 8 6 Overriding N A 2 8 7 Switches relays and their related circuit
87. fferences based on national regulatory requirements such as the Canadian Electrical Code CEC Part and the Canadian Building Code which are referenced in legislation and which form the basis for the rules and practices followed in electrical and building installations All equipment is to be designed to allow installation Considered P in accordance with the National Electrical Code NEC ANSI NFPA 70 the Canadian Electrical Code CEC Part I CAN CSA C22 1 and when applicable the National Electrical Safety Code IEEE C2 Also unless marked or otherwise identified installation is allowed per the Standard for the Protection of Electronic Computer Data Processing Equipment ANSI NFPA 75 For Pluggable Equipment Type A the protection in Considered P the installation is assumed to be 20A For lengths exceeding 3 05 m external N A interconnecting flexible cord and cable assemblies are required to be a suitable cable type e g DP CL2 specified in the CEC NEC For lengths 3 05 m or less external interconnecting flexible cord and cable assemblies that are not types specified in the CEC are required to have special construction features and identification markings Equipment for use on a c mains supply systems N A with a neutral and more than one phase conductor e g 120 240 V 3 wire require a special marking format for electrical ratings A voltage rating that exceeds an attachment plug cap rating is only permitted
88. from mains to DC output connector and metal enclosure accessible parts metal enclosure 5 1 6 Test measurements See below P Supply voltage V See appended table 5 1 6 Measured touch current mA See appended table 5 1 6 Max allowed touch current mA See appended table 5 1 6 Measured protective conductor current mA Max allowed protective conductor current mA 5 1 7 Equipment with touch current exceeding 3 5 mA Neither stationary permanently N A connected equipment nor stationary pluggable equipment type B 5 1 7 1 General E AE E E AATE NE N A 5 1 7 2 Simultaneous multiple connections to the supply N A 5 1 8 Touch currents to telecommunication networks and No TNV N A cable distribution systems and from telecommunication networks 5 1 8 1 Limitation of the touch current to a telecommunication N A network or to a cable distribution system Supply voltage V ceeeseceeeeeeeeeeeeeeeeeeeeeeeeeeess Measured touch current mA Max allowed touch current mA 5 1 8 2 N A Summation of touch currents from telecommunication networks TRF No IEC60950_1B A TUVRheinland www tuv com Page 30 of 112 Report No 16041780 001 IEC 60950 1 Clause Requirement Test Result Remark Verdict a EUT with earthed tele
89. gs in enclosures N A 4 6 1 Top and side openings This equipment is for N A building in Compliance shall be evaluated after installation into the final system Dimensions mm eeee 4 6 2 Bottoms of fire enclosures N A Construction of the bottomm dimensions mm 4 6 3 Doors or covers in fire enclosures N A 4 6 4 Openings in transportable equipment N A TRF No IEC60950 1B www tuv com Page 28 of 112 A T VRheinland Report No 16041780 001 provided IEC 60950 1 Clause Requirement Test Result Remark Verdict 4 6 4 1 Constructional design measures E N A Dimensions mm eeee Po 4 6 4 2 Evaluation measures for larger openings EE N A 4 6 4 3 Use of metallized parts S N A 4 6 5 Adhesives for constructional purposes Pe N A Conditioning temperature C time weeks Po 4 7 Resistance to fire 4 7 1 Reducing the risk of ignition and spread of flame Use of materials with the required flammability classes Method 1 selection and application of components see appended table 4 7 P wiring and materials Method 2 application of all of simulated fault N A condition tests 4 7 2 Conditions for a fire enclosure See below 4 7 2 1 Parts requiring a fire enclosure With having the following parts Components in primary Components in secondary Components having unenclosed arcing parts at hazardous voltage or energy lev
90. harp Corp Fairchild Everlight IEC 60950 1 Various sid PC817 H11A817 EL817 Min 0 8A min 0 8A min 700V di 2 0 5 mm int dcr 6 5mm ext dcr 8 0mm 100 C di 0 6mm ext dcr 7 0 mm Thermal cycling test 100 C di 0 5mm int dcr 6 0mm ext der 7 7 mm 100 C IEC EN 60950 1 EN 60747 5 2 IEC EN 60950 1 EN 60747 5 2 IEC EN 60950 1 EN 60747 5 2 Requirement Test Result Remark Verdict VDE 40008087 UL E64380 VDE 40026857 UL E90700 VDE 132249 UL E214129 Alternative Alternative Line Filter LF 1 Optional Line Filter LF2 Optional Toshiba Renesas SI Tech Corp Ltd SI Tech Corp Ltd TLP721 PS2561 Series EE 25 KL 011774G di 0 8 mm ext dcr 8 0mm 100 C Dti gt 0 4mm ext dcr gt 7 0mm 100 C Thermal cycling test N1 pin 1 2 00 6mm x 37 5Ts N2 pin 3 4 0 6mm x 37 5Ts Min 105 C N1 pin 1 4 0 8mm x 10 5Ts N2 pin 2 3 0 8mm x 10 5Ts Min 105 C IEC EN 60950 1 EN 60747 5 2 IEC EN 60950 1 EN 60747 5 2 VDE40009373 UL E67349 Semko 1017620 UL E72422 Drive Choke T3 SI Tech Corp Ltd TRF No IEC60950 1B EE 13 N3 pin 8 9 00 27mm x 30Ts N2 pin 1 2 0 25mm x 30Ts N1 pin 4 5 0 25mm x 30Ts Min 130 C A TUVRheinland www tuv com Page 43 of 112 Report No 16041780 001 IEC 60950 1 Requirement Test Resul
91. have been inserted in place of some of the International Standards Israel National Differences according to CB Bulletin www tuv com Page 98 of 112 A T VRheinland Report No 16041780 001 Clause IEC60950 1B ATTACHMENT National Differences Requirement Test Resut Remak Remark Verdict J 60950 1 H22 2009 TEST REPORT Deviations from IEC 60950 1 2001 first edition Special National conditions National deviation and other information according to MITI Ordinance No 85 Japanese unique deviations in J60950 1 H22 2009 JIS C 6950 1 2009 1 2 4 1 1 2 4 3A Add the following new notes Note Even if the equipment is designed as Class the equipment is regarded as Class 0l equipment when 2 pin adaptor with earthing lead wire or cord set having 2 pin plug with earthing lead wire is provided or recommended Add the following new clause 1 2 4 3A CLASS 01 EQUIPMENT Equipment having attachment plug without earthing blade where protection against electric shock is achieved by using BASIC INSULATION and providing externally an earth terminal or a lead wire for earthing in order to connect those conductive parts that might assume a HAZARDOUS VOLTAGES in the event of BASIC INSULATION fault to the PROTECTIVE EARTHING CONDUCTOR in the building wiring NOTE Class 0l equipment may have a part constructed with Double Insulation or Reinforced Insulation circuit Add the
92. ide no damaged The equipment is for building in compliance have to evaluated in the final system 4 2 5 Impact test Impact force applied to front N A metal chassis near AC Inlet No hazards as result after test The equipment is for building in compliance have to evaluated in the final system Fall test N A 4 2 6 Drop test height MM Ro fo NA 4 2 7 Stress relief test Metal chassis N A 4 2 8 Cathode ray tubes No CRT provided N A Picture tube separately certified ELIT N A 4 2 9 High pressure lamps No high pressure lamps N A provided 4 2 10 Wall or ceiling mounted equipment force N Not wall or ceiling mounted N A equipment 4 2 11 Rotating solid media PN Test to cover on the door c ceceeeeeeeeeeeeeel N A 4 3 Design and construction P 4 3 1 Edges and corners All edges and corners are P rounded and or smoothed 4 3 2 Handles and manual controls force N N A 4 3 3 Adjustable controls No controls provided N A 4 3 4 Securing of parts No connection likely to be P exposed to mechanical stress is provided in unit 4 3 5 Connection by plugs and sockets No mismating of connectors P plugs or sockets possible 4 3 6 Direct plug in equipment Equipment is not direct plug N A in type Torque ene ni ae ME Compliance with the relevant mains plug standard N A 4 3 7 Heating elements in earthed equipment No heating elements N A TRF No IEC60950_1B A T VRh
93. include attachment plugs battery packs rechargeable type used with transportable equipment cathode ray tubes circuit breakers communication circuit accessories connectors used for current interruption of non LPS circuits cord sets and power supply cords direct plug in equipment enclosures outdoor flexible cords and cables fuses branch circuit fuseholders ground fault current interrupters industrial control equipment insulating tape interconnecting cables lampholders limit controls printed wiring protectors for communications circuits receptacles solid state controls supplementary protectors switches including interlock switches thermal cutoffs thermostats multi layer transformer winding wire transient voltage surge suppressors tubing wire connectors and wire and cables 1 6 1 2 A circuit for connection to the DC Mains Supply is classified as either a SELV Circuit TNV 2 Circuit or Hazardous Voltage Circuit depending on the maximum operating voltage of the supply This maximum operating voltage it to include consideration of the battery charging float voltage associated with the intended supply system regardless of the marked power rating of the equipment IEC60950 1B ATTACHMENT National Differences Requirement Test Result Remark A T VRheinland Report No 16041780 001 Verdict Not information storage systems No such enclosure No ionizing radiation see append
94. ion in operator access areas DC fans are protected by a P metal cover and the openings that prevent the test finger from entering TRF No IEC60950 1B A TUVRheinland www tuv com Page 27 of 112 Report No 16041780 001 IEC 60950 1 Clause Requirement Test Pesut Remak veraict Household and home office document media Ys N A shredders 4 4 3 Protection in restricted access locations d N A 4 4 4 Protection in service access areas i 4 N A 4 4 5 Protection against moving fan blades See below P 4 4 5 1 General The test finger cannot touch P the blades of DC fan Not considered to cause pain or injury a lL 7 l N A Is considered to cause pain not injury b N A Considered to cause injury C idea N A 4 4 5 2 Protection for users N A the blades of DC fan Use of symbol or warning ceseeeeeeeee eee eed p N A 4 4 5 3 Protection for service persons N A Use of symbol or warning eee N A 4 5 Thermal requirements 4 5 1 General 4 5 2 Temperature tests See appended table 4 5 P Normal load condition per Annex L See appended table 1 6 2 4 5 3 Temperature limits for materials see appended table 4 5 P 4 5 4 Touch temperature limits see appended table 4 5 P 4 5 5 Resistance to abnormal heat see appended table 4 5 5 P 4 6 Openin
95. ion of user instructions maintenance and or N A servicing instructions ssssust EE 3 Inadvertent reactivation test esses N A EE 4 Disconnection of power to hazardous moving parts N A Use of markings or symbols t N A EE 5 Protection against hazardous moving parts N A Test with test finger Figure 2A N A Test with wedge probe Figure EE1 and EE2 N A TRF No IEC60950 1B www tuv com Page 39 of 112 A TUVRheinland Report No 16041780 001 IEC 60950 1 Requirement Test Result Remark Verdict Technical data _ Manufacturer Type model Standard Edition Mark s of trademark year conformity Various Various Metal min 0 7 mm thick Appliance Inlet Bei Er Jia ST A01 Series 10A 250Vac IEC EN 60320 1 VDE Type C14 40013388 UL E225980 Voltage Zhangjiagang HF 308 10A 250V IE4 IEC EN 61058 1 VDE 104073 Selector Huafeng T85 UL E128307 Switch SW1 Alternative Canal SL 15 Series 10 A 250 Vac IEC EN 61058 1 VDE 1E4 T85 40026318 UL E81103 Alternative Zhe Jiang Bei Er PS10 10 A 250 Vac IEC EN 61058 1 VDE Jia 1E4 T85 40023251 UL E236875 Dong Guan New NE5000A V 0 130 C e UL E206420 Energy Printed Circuit Board Alternative Various Various V 1 or better 130 C min Fuse F1 for Littelfuse 215 T5 0A 250Vac IEC EN 60127 1 V
96. ivation of the higher level Zx 4 Requirements for listening devices headphones and earphones N A Zx 4 1 Wired listening devices with analogue input N A With 94 dBA sound pressure output Laeg T the input voltage of the fixed programme simulation noise described in EN 50332 2 shall be 2 75 mV Zx 4 2 Wired listening devices with digital input N A The acoustic output LAeg T of the listening device shall be s 100 dBA Zx 4 3 Wireless listening devices N A The acoustic output Laeq T of the listening device shall be x 100 dBA Zx 5 Measurement methods N A Measurements shall be made in accordance with EN 50332 1 or EN 50332 2 as applicable Unless stated otherwise the time interval T shall be 30 s www tuv com Clause APPENDIX 1 2 12 15 1 5 1 1 5 2 Page 81 of 112 IEC60950 1B ATTACHMENT National Differences Requirement Test Result Remark Verdict Australian National Differences according to CB Bulletin AS NZS 60950 1 2003 A1 A2 A3 IEC Publication 60950 1 2001 EXPLANATION FOR ABBREVIATIONS P Pass F Fail N A Not applicable Placed in the column to the right Annex ZZ Variations Between the definitions for Person service and Range rated frequency insert the following Potential ignition source 1 2 12 201 After the definition of 1 2 12 15 add the following 1 2 12 201 Potential ignition source Possible fault which can start a fire if the ope
97. mination of minimum clearances N A H ANNEX H IONIZING RADIATION see 4 3 13 N A J ANNEX J TABLE OF ELECTROCHEMICAL POTENTIALS see 2 6 5 6 P Metal s used eeeseeseeeeeeel No risk of corrosion K ANNEX K THERMAL CONTROLS see 1 5 3 and 5 3 8 N A Making and breaking capacity N A Thermostat reliability operating voltage V N A Thermostat endurance test operating voltage V N A Temperature limiter endurance operating voltage V N A Thermal cut out reliability N A Stability of operation N A L ANNEX L NORMAL LOAD CONDITIONS FOR SOME TYPES OF ELECTRICAL P BUSINESS EQUIPMENT see 1 2 2 1 and 4 5 2 L 1 Typewriters N A L 2 Adding machines and cash registers N A L 4 Pencil sharpeners N A L 5 Duplicators and copy machines N A L 6 Motor operated files N A L 7 Other business equipment P M ANNEX M CRITERIA FOR TELEPHONE RINGING SIGNALS see 2 3 1 N A M 1 Introduction No telephone signal N A M 2 Method A N A M 3 Method B N A TRF No IEC60950_1B A TUVRheinland www tuv com Page 36 of 112 Report No 16041780 001 IEC 60950 1 M 3 1 Ringing signal N A M 3 1 1 Frequency Hz M 3 1 2 Voltage V M 3 1 3 Cadence time s voltage V M 3 1 4 Single fault current mA M 3 2 Tripping device and monitoring voltage N A M 3 2 1 Conditions for use of a tripping device or a monitoring N A voltage M 3 2 2 Tripping devic
98. n circuit voltage measured across an interruption or faulty contact exceeds a value of 50 V peak a c or d c and the product of the peak value of this voltage and the measured r m s current under normal operating conditions exceeds 15 VA Such a faulty contact or interruption in an electrical connection includes those which may occur in conductive patterns on printed boards NOTE 201 An electronic protection circuit may be used to prevent such a fault from becoming a potential ignition source NOTE 202 This definition is from AS NZS 60065 2003 Add the following to the end of first paragraph or the relevant Australian New Zealand Standard Add the following to the end of first and third dash items or the relevant Australian New Zealand Standard Delete the Note Delete Note 2 Modify Table 3B as follows Rated current of Nominal AWG or kcmil equipment A cross cross sectional sectional area in mm2 area mm2 see note 2 Over 0 2 upto 0 51 18 0 8 and including 3 Over 3 up to and 0 75 16 1 3 including 7 5 Over7 5upto 0 75 2 1 00 16 1 3 and including 10 Over 10 up to 1 0 3 1 5 14 2 and including 16 Australian National Differences according to CB Bulletin Inserted Added Added Should be eval national approval Deleted Deleted Replaced A TUVRheinland Report No 16041780 001 uated during N A N A N A A TUVRheinland www tuv com
99. nd earth fault protection may be provided by protective devices in the building installation IEC60950 1B ATTACHMENT National Differences Clause Requirement Test A T VRheinland Report No 16041780 001 Result Remark www tuv com 2 7 2 3 2 3 3 2 5 1 3 3 4 4 3 13 6 A1 2010 Page 65 of 112 TYPE B or PERMANENTLY CONNECTED EQUIPMENT to rely on dedicated overcurrent and short circuit protection in the building installation provided that the means of protection e g fuses or circuit breakers is fully specified in the installation instructions If reliance is placed on protection in the building installation the installation instructions shall so state except that for PLUGGABLE EQUIPMENT TYPE A the building installation shall be regarded as providing protection in accordance with the rating of the wall socket outlet This subclause has been declared void Delete the NOTE in Table 3A and delete also in this table the conduit sizes in parentheses Replace 60245 IEC 53 by H05 RR F 60227 IEC 52 by H03 VV F or H03 VVH2 F 60227 IEC 53 by H05 VV F or H05 VVH2 F2 In Table 3B replace the first four lines by the following Up to and including 6 0 75 Over 6 up to and including 10 0 75 1 0 Over 10 up to and including 16 1 0 1 5 In the conditions applicable to Table 3B delete the words in some countries in condition
100. ndary windings detail appended table 2 10 3 and 2 10 4 2 10 5 7 Separable thin sheet material P Number of layers pcs Atleast two layers of insulation tape used between primary and secondary of transformers T1 T2 as reinforced insulation Atleast two layers of insulation tape covered heatsink SH1 as reinforced insulation TRF No IEC60950_1B A TUVRheinland www tuv com Page 20 of 112 Report No 16041780 001 IEC 60950 1 Clause Requirement Test Result Remark Verdict 2 10 5 8 Non separable thin sheet material Not such marterial N A 2 10 5 9 Thin sheet material standard test procedure See 2 10 5 10 N A Electric strength test see appended table 2 10 5 2 10 5 10 Thin sheet material alternative test procedure Electric strength test applied P to each layer Electric strength test See appended table 5 2 2 10 5 11 Insulation in wound components N A 2 10 5 12 Wire in wound components N A Working voltage seeeeenmI N A a Basic insulation not under stress N A b Basic supplemetary reinforced insulation N A c Compliance with Annex U seeesese N A Two wires in contact inside wound component ns N A between 45 and 90 ssssssese 2 10 5 13 Wire with solvent based enamel in wound No such construction N A components Electric strength test Routine test
101. ntended for connection to other equipment or a network shall if safety relies on connection to protective earth or if surge suppressors are connected between the network terminals and accessible parts have a marking stating that the equipment must be connected to an earthed mains socket outlet The marking text in the applicable countries shall be as follows In Finland Laite on liitett v suojakoskettimilla varustettuun pistorasiaan In Norway Apparatet m tilkoples jordet stikkontakt In Sweden Apparaten skall anslutas till jordat uttag In Norway and Sweden the screen of the cable distribution system is normally not earthed at the entrance of the building and there is normally no equipotential bonding system within the building Therefore the protective earthing of the building installation need to be isolated from the screen of a cable distribution system It is however accepted to provide the insulation external to the equipment by an adapter or an interconnection cable with galvanic isolator which may be provided by e g a retailer The user manual shall then have the following or similar information in Norwegian and Swedish language respectively depending on in what country the equipment is intended to be used in Equipment connected to the protective earthing of the building installation through the mains connection or through other equipment with a connection to protective earthing and to a cable di
102. nufacturer Same as applicant Model Type reference WMS 200SFX WMS 250SFX Ratings 01er eet Rd Input 115Vac 230Vac 50 60Hz 5A Output See model list on page 7 A TUVRheinland www tuv com Page 2 of 112 Report No 16041780 001 Testing procedure and testing location EJ CB Testing Laboratory T V Rheinland Guangdong Ltd Testing location address No 199 Kezhu Road Guangzhou Science City 510663 x China Testing location address Approved by name signature Pony Xiong Ec ae ae DH Testing procedure TMP N A Testing location address Tested by name signature Witnessed by name Pi Tested by name signature Approved by name signature Supervised by name signature TRF No IEC60950 1B A T VRheinland www tuv com Page 3 of 112 Report No 16041780 001 List of Attachments including a total number of pages in each attachment Attachment National differences 50 pages Attachment Photo documentation 15 pages Summary of testing Tests performed name of test and test clause Testing location 1 6 2 Input Current Test TUV Rheinland Guangdong Ltd 1 7 11 Durability Of Marking Test No 199 Kezhu Road Guangzhou Science City 2 1 1 5 Energy Hazard In Operator Access Sees munfidehiouohing Area 2 14 7 Discharge of capacitor 2 2
103. on for obtaining a CB Test Certificate X Yes includes more than one factory location and a declaration from the Manufacturer stating that the sample s submitted for evaluation is are representative of the products from each factory has been provided i uin trt dede eed LI Not applicable When differences exist they shall be identified in the General product information section Name and address of factory ies Winsis Inc Shenzhen Block A Plant Junwei Xin Tongfu Yu Industrial Park Zhenmei Rd Guangming New District Shenzhen P R China General product information Brief description of the test sample 1 The equipment models WMS 200SFX WMS 250SFX were building in switching power supply for the use in information technology equipment 2 Specified maximum ambient temperature is 45 C 3 Pre production samples without serial numbers 4 As building in equipment some clauses are not considered in this report and should be evaluated in the final system such as Resistance to fire should be re considered in the end system Models difference Both models are similar except for type designation output rating and electrical rating of some components details as below C1 C2 F1 THR1 BD1 Q1 Q2 R22 DB1 DB2 the parameters of these components depend on output power and output current Model list Model Input Rating Outputs Rating DC A max Combined Power
104. on of electromagnetic interference Should be considered during N A national approval Prior to carrying out the tests in accordance with the clauses of this Standard the compliance of the apparatus with the relevant requirements specified in the appropriate part of the Standard series SI 961 shall be checked The apparatus shall meet the requirements in the appropriate part of the Standard series SI 961 If there are components in the apparatus for the prevention of electromagnetic interference these components shall not reduce the safety level of the apparatus as required by this Standard 3 The clause is applicable with the following Added P additions 3 2 1 1 Connection to an a c mains supply Appliance inlet used N A After the note the following note shall be added Note In Israel the feed plug shall comply with the requirements of Israel Standard SI 32 Part 1 1 3 2 1 2 Connection to a d c mains supply N A At the end of the first paragraph the following note shall be added Note At the time of issue of this Standard there is no Israel Standard for connection accessories to d c Israel National Differences according to CB Bulletin A TUVRheinland www tuv com Page 97 of 112 Report No 16041780 001 IEC60950 1B ATTACHMENT National Differences Clause Requirement Test Result Remark Verdict Annex P Normative references P List of relevant Israel Standards that
105. on the maximum operating voltage of the supply This maximum operating voltage shall include consideration of the battery charging float voltage associated with the intended supply system regardless of the marked power rating of the equipment 2 3 1 For TNV 2 and TNV 3 circuits with other than No TNV circuits N A ringing signals and with voltages exceeding 42 4 Vpeak or 60 Vd c the maximum acceptable current through a 2000 ohm resistor or greater connected across the voltage source with other loads disconnected is 7 1 mA peak or 30 mA d c under normal operating conditions 2 3 2 1 In the event of a single fault between TNV and No TNV circuits N A SELV circuits the limits of 2 2 3 apply to SELV Circuits and accessible conductive parts 2 6 3 3 The current rating of the circuit shall be taken as P 20A not 16A Canada National Differences according to CB Bulletin A TUVRheinland www tuv com Page 93 of 112 Report No 16041780 001 IEC60950 1B ATTACHMENT National Differences Clause Requirement Test Result Remark Verdict 2 6 3 4 Protective bonding conductors of non standard Considered P protective bonding constructions e g printed circuit traces may be subjected to the additional limited short circuit test conditions specified 4 2 8 1 Enclosures around CRTs with a face diameter of No CRT N A 160 mm or more are required to reduce the risk of injury due to the implosion of the CRT 4 3
106. onal Differences Requirement Test Result Remark Verdict APPENDIX Chinese National Differences according to CB Bulletin GB4943 2001 IEC Publication 60950 1999 EXPLANATION FOR ABBREVIATIONS P Pass F Fail N A Not applicable 1 4 5 If the equipment is intended for direct connection Considered to an AC MAINS SUPPLY the tolerances on RATED VOLTAGE shall be taken as 10 and 10 unless 1 7 1 When single rated voltage is given it should be The input voltage range is 100 marked 220 V when a rating range is given the 240V or 200 240Vac voltage range shall have a hyphen between the minimum and maximum RATED VOLTAGES and should cover 220 V When multiple RATED VOLTAGES or RATED VOLTAGE RANGES are given they shall be separated by a solidus and one of them must be 220 V and also factory default setting should be 220 V RATED FREQUENCY or RATED FREQUENCY RANGE should be 50Hz or cover 50Hz unless the equipment is designed for d c only 1 7 12 Instructions and equipment marking related to Should be considered during N A safety shall be written in simplified Chinese in national approval which the equipment is to be installed 3 2 1 Plugs of apparatus which are intended for the Appliance inlet used connection of the mains supply should comply with requirements of GB1002 N A Chinese National Differences according to CB Bulletin A TUVRheinland www tuv com Page 95 of 112
107. onditions of 5 1 7 3 5 subject to the conditions of 5 1 7 5 of input current HAND HELD Equipment main 0 5 protective earthing Others terminal 1 0 if any CLASS 0I EQUIPMENT If peak values of TOUCH CURRENT are measured the maximum values obtained by multiplying the r m s values by 1 414 7 2 Add the following after the paragraph N A However the separation requirements and tests of 6 2 1 a b and c do not apply to a CABLE DISTRIBUTION SYSTEM if all of the following apply the circuit under consideration is a TNV 1 CIRCUIT and the common or earthed side of the circuit is connected to the screen of the coaxial cable and to all accessible parts and circuits SELV accessible metal parts and LIMITED CURRENT CIRCUITS if any and the screen of the coaxial cable is intended to be connected to earth in the building installation Japanese Deviations for J60950 1 H22 2009 MITI Ordinance Clause 2 www tuv com Page 103 of 112 A T VRheinland Report No 16041780 001 Clause IEC60950 1B ATTACHMENT National Differences Requirement Test Result Remark Verdict W 1 Replace second and third sentence in the first paragraph with the following This distinction between earthed and unearthed floating circuit is not the same as between CLASS EQUIMENT CLASS 0l EQUIPMENT and CLASS Il EQUIPMENT Floating circuits can exist in CLASS EQUIPMENT or CLASS Ol EQ
108. ormative Normative references to international publications with their corresponding European publications Annex ZB normative Special national conditions General Delete all the country notes in the reference document IEC 60950 1 2005 according to the following list 1 4 8 Note 2 1 5 1 Note2 amp 3 1 5 7 1 Note 1 5 8 Note 2 1 5 9 4 Note 1 7 2 1 Note 4 5 amp 6 2 2 8 Note 2 2 4 Note 2 3 2 Note 2 3 2 1 Note 2 2 3 4 Note 2 2 6 3 3 Note 2 amp 3 2 7 1 Note 2 10 3 2 Note 2 2 10 5 13 Note 3 3 2 1 1 Note 3 2 4 Note 3 2 5 1 Note 2 4 3 6 Note1 amp 2 47 Note 4 4 7 2 2 Note 4 7 3 1Note 2 5 1 7 1 Note3 amp 4 5 3 7 Note 1 6 Note2 amp 5 6 1 2 1 Note 2 6 1 2 2 Note 6 2 2 Note 6 2 2 1 Note 2 6 2 2 2 Note 7 1 Note3 7 2 Note 7 3 Note 1 amp 2 G 2 1 Note 2 Annex H Note 2 General Delete all the country notes in the reference document IEC 60950 A1 2010 1 2005 A1 2010 according to the following list 1 5 7 1 Note 6 1 2 1 Note 2 6 2 2 1 Note 2 EE 3 Note www tuv com 1 3 21 1 5 1 1 7 2 1 A1 2010 2 7 1 Page 64 of 112 Add the following subclause 1 3 21 Exposure to excessive sound pressure The apparatus shall be so designed and constructed as to present no danger when used for its intended purpose either in normal operating conditions or under fault conditions particularly providing protection against exposure to excessive sound pressures from headphones or earphones NOTE Z1 A new method of measurement is described in
109. porting potential ignition sources shall be subject to the glow wire test of AN NZS 4695 2 11 which is carried out at 750 C The test shall be also carried out on other parts of insulating material which are within a distance of 3 mm of the connection NOTE Contacts in components such as switch contacts are considered to be connections For parts which withstand the glow wire test but produce a flame other parts above the connection within the envelope of a vertical cylinder having a diameter of 20 mm and a height of 50 mm shall be subjected to the needle flame test However parts shielded by a barrier which meets the needle flame test shall not be tested The needle flame test shall be made in accordance with AS NZS 4695 2 2 with the following modifications 5 Severities Replace with The duration of application of the test flame shall be 30st1s 8 Test procedure 8 2 Modification Replace the first sentence with The specimen shall be arranged so that the flame can be applied to a vertical or horizontal edge as shown in the examples of figure 1 8 4 Modification The first paragraph does not apply Addition If possible the flame shall be applied at least 10 mm from a corner 8 5 Replacement The test shall be made on one specimen If the specimen does not withstand the test the test may be repeated on two further specimens both of which shall then withstand the test 10 Evaluation of test results
110. rdinance 1990 944 Add the following NOTE In Sweden switches containing mercury are not permitted No switch provided N A 1 7 2 1 Switzerland Ordinance on environmentally hazardous substances SR 814 081 Annex 1 7 Mercury Annex 1 7 of SR 814 81 applies for mercury Add the following NOTE In Switzerland switches containing mercury such as thermostats relays and level controllers are not allowed Denmark Heavy Current Regulations Supply cords of CLASS EQUIPMENT which is delivered without a plug must be provided with a visible tag with the following text Vigtigt Lederen med gren gul isolation ma kun tilsluttes en kemme m rket D eller If essential for the safety of the equipment the tag must in addition be provided with a diagram which shows the connection of the other conductors or be provided with the following text For tilslutning af de vrige ledere se medf lgende installationsvejledning Germany Gesetz Uber technische Arbeitsmittel und Verbraucherprodukte Ger te und Produktsicherheitsgesetz GPSG Law on technical labour equipment and consumer products of 6th January 2004 Section 2 Article 4 Clause 4 Item 2 If for the assurance of safety and health certain rules during use amending or maintenance of a technical labour equipment or readymade consumer product are to be followed a manual in German language has to be delivered when placing the produc
111. rent protection No such components provided N A 3 2 1 3 2 1 2 3 2 3 Wiring methods terminals leads etc used for the connection of the equipment to the mains shall be in accordance with the NEC CEC Power supply cords are required to have attachment plugs rated not less than 125 percent of the rated current of the equipment Equipment connected to a centralized d c power system and having one pole of the DC mains input terminal connected to the main protective earthing terminal in the equipment is required to comply with special earthing wiring marking and installation instruction requirements Permanent connection of equipment to the mains supply by a power supply cord is not permitted except for certain equipment such as ATMs Appliance inlet used no power cord provided Not such equipment Equipment is not permanent connection type N A N A N A 3 2 5 Power supply cords are required to be no longer than 4 5 m in length Flexible power supply cords are required to be compatible with Tables 11 and 12 of the CEC and Article 400 of the NEC No power cords provided Shall be considered during national approval N A 3 2 9 Permanently connected equipment is required to have a suitable wiring compartment and wire bending space Wiring terminals and associated spacings for field wiring connections shall comply with CSA C22 2 No 0 Canada National Differences a
112. required according to the wiring rules shall be provided with a plug in accordance with standard UNE 20315 1994 If poly phase equipment is provided with a supply cord with a plug this plug shall be in accordance with UNE EN 60309 2 In the United Kingdom apparatus which is fitted with a flexible cable or cord and is designed to be connected to a mains socket conforming to BS 1363 by means of that flexible cable or cord and plug shall be fitted with a standard plug in accordance with Statutory Instrument 1768 1994 The Plugs and Sockets etc Safety Regulations 1994 unless exempted by those regulations NOTE Standard plug is defined in SI 1768 1994 and essentially means an approved plug conforming to BS 1363 or an approved conversion plug For appliance inlet appliance should be considered during national approval N A N A www tuv com 3 2 1 1 3 2 4 3 2 5 1 3 3 4 4 3 6 4 3 6 Page 71 of 112 In Ireland apparatus which is fitted with a flexible cable or cord and is designed to be connected to a mains socket conforming to l S 411 by means of that flexible cable or cord and plug shall be fitted with a 13 A plug in accordance with Statutory Instrument 525 1997 National Standards Authority of Ireland section 28 13 A Plugs and Conversion Adaptors for Domestic Use Regulations 1997 In Switzerland for requirements see 3 2 1 1 of this annex In the United Kingdom a
113. rst and second paragraph of the compliance clause 6 1 2 1 A1 2010 If this insulation is solid including insulation forming part of a component it shall at least consist of either two layers of thin sheet material each of which shall pass the electric strength test below or one layer having a distance through insulation of at least 0 4 mm which shall pass the electric strength test below Alternatively for components there is no distance through insulation requirement for the insulation consisting of an insulating compound completely filling the casing so that CLEARANCES and CREEPAGE DISTANCES do not exist if the component passes the electric strength test in accordance with the compliance clause below and in addition passes the tests and inspection criteria of 2 10 11 with an electric strength test of 1 5 kV multiplied by 1 6 the electric strength test of 2 10 10 shall be performed using 1 5 kV and is subject to ROUTINE TESTING for electric strength during manufacturing using a test voltage of 1 5 kV A T VRheinland www tuv com Page 78 of 112 Report No 16041780 001 IEC60950_1B ATTACHMENT National Differences Clause Requirement Test Result Remark Verdict It is permitted to bridge this insulation with an Not such equipment N A optocoupler complying with 2 10 5 4 b It is permitted to bridge this insulation with a capacitor complying with EN 60384 14 2005 subclass Y
114. rst paragraph Not connected to cable N A Equipment providing functions that fall only within distribution system the scope of AS NZS 60065 and that incorporate a PSTN interface are not required to comply with this Clause where the only ports provided on the equipment in addition to a coaxial cable connection and a PSTN interface are audio or video ports and analogue or data ports not intended to be used for telecommunications purposes Annex M 2 Delete the second and third equations and replace No TNV N A with t 600 L 1200 t hi for 600 ms t 1 200 ms hs 00 a 60 dz l for t gt 1 200 ms Australian National Differences according to CB Bulletin A TUVRheinland www tuv com Page 88 of 112 Report No 16041780 001 IEC60950 1B ATTACHMENT National Differences Clause Requirement Test Result Remark Verdict Annex P Add the following Normative References to Annex Added P P IEC 60065 Audio Video and similar electronic apparatus Safety requirements AS NZS 3112 Approval and test specification Plugs and socket outlets AS NZS 3191 Approval and test specification Electric flexible cords AS NZS 4695 707 Fire hazard testing of electrotechnical products Methods of test for the determination of the flammability of solid electrical insulating materials when exposed to an igniting source Annex ZZ 2 Add the following after Clause 3 2 5 1 No such device N A
115. s Requirement Test Result Remark APPENDIX US National Differences according to CB Bulletin A T VRheinland Report No 16041780 001 Verdict EXPLANATION FOR ABBREVIATIONS P Pass F Fail N A Not applicable Placed in the column to the right SPECIAL NATIONAL CONDITIONS BASED ON FEDERAL REGULATIONS All equipment is to be designed to allow installation in accordance with the National Electrical Code NEC ANSI NFPA 70 and when applicable the National Electrical Safety Code IEEE C2 Also unless marked or otherwise identified installation is allowed per the Standard for the Protection of Electronic Computer Data Processing Equipment ANSI NFPA 75 For Pluggable Equipment Type A the protection in the installation is assumed to be 20A Considered For lengths exceeding 3 05 m external interconnecting flexible cord and cable assemblies are required to be a suitable cable type specified in the NEC For lengths 3 05 m or less external interconnecting flexible cord and cable assemblies that are not types specified in the NEC are required to have special construction features and identification markings Equipment for use on a c mains supply systems with a neutral and more than one phase conductor e g 120 240 V 3 wire require a special marking format for electrical ratings Where a fuse is used to provide Class 2 Limited Power Source or TNV current limiting it shall not be operator a
116. s N A 2 8 7 1 Separation distances for contact gaps and their N A related circuits mm eeeeeeesee 2 8 7 2 Overload test N A 2 8 7 3 Endurance test N A 2 8 7 4 Electric strength test N A 2 8 8 Mechanical actuators N A 2 9 Electrical insulation 2 9 1 Properties of insulating materials Natural rubber asbestos or hygroscopic material are not used 2 9 2 Humidity conditioning 120 h based on client request also conducted for opto coupler type PS2561 Series Relative humidity 96 temperature C 93 RH 40 C 2 9 3 Grade of insulation Insulation complies with sub clauses 2 10 4 5 1 and 5 2 2 9 4 Separation from hazardous voltages The secondary circuit is TRF No IEC60950 1B seperated from hazardaous voltages by reinforce insulation A T VRheinland Report No 16041780 001 www tuv com Page 18 of 112 IEC 60950 1 Clause Requirement Test Result Remark Verdict Method s used esee Method 1 used 2 10 Clearances creepage distances and distances through insulation P 2 10 1 General See 2 10 3 2 10 4 and 2 10 5 P 2 10 1 1 Frequency eodeni e e merce P 2 10 1 2 Pollution degrees eeeeeseeeeeesssee 2 P 2 10 1 3 Reduced values for functional insualtion See 5 3 4 N A 2 10 1 4 Intervening unconnected conductive parts No such part N A 2 10 1 5 Insulation with varying dimensions No such tran
117. s for N A connection of external conductors provided 3 3 2 Connection of non detachable power supply cords N A 3 3 3 Screw terminals N A 3 3 4 Conductor sizes to be connected N A Rated current A cord cable type cross sectional area mm Eaa 3 3 5 Wiring terminal sizes N A Rated current A type nominal thread diameter MM p 3 3 6 Wiring terminal design N A 3 3 7 Grouping of wiring terminals N A 3 3 8 Stranded wire N A 3 4 Disconnection from the mains supply P 3 4 1 General requirement Disconnect device provided P 3 4 2 Disconnect devices See sub clause 1 7 2 2 P 3 4 3 Permanently connected equipment Not permanently connected N A equipment 3 4 4 Parts which remain energized There is no parts remained P with hazardous voltage or energy in the equipment when SPS is separated from AC mains 3 4 5 Switches in flexible cords No such flexible cords N A 3 4 6 Number of poles single phase and d c equipment The appliance inlet P disconnects both poles simultaneously 3 4 7 Number of poles three phase equipment Single phase equipment N A 3 4 8 Switches as disconnect devices See sub clause 1 7 2 2 N A 3 4 9 Plugs as disconnect devices See sub clause 3 4 2 N A TRF No IEC60950 1B A TUVRheinland www tuv com Page 24 of 112 Report No 16041780 001 IEC 60950 1 Clause Requirement Test Result Remark Verdict Interconnected equipment No interconnections using N A hazardous
118. s required to comply No handles with special loading tests 5 1 8 3 Equipment intended to receive No TNV telecommunication ringing signals is required to comply with a special touch current measurement tests 5 3 7 Internal e g card cage SELV circuit connectors and printed wiring board connectors that are accessible to the operator and that deliver power are to be overloaded During abnormal operating testing if a circuit is interrupted by the opening of a component the test shall be repeated twice three tests total using new components as necessary 6 4 Equipment intended for connection to No such equipment telecommunication network outside plant cable is required to be protected against overvoltage from power line crosses in accordance with 6 4 2 and Annex NAC M Continuous ringing signals up to 16 mA only No such equipment are permitted if the equipment is subjected to special installation and performance restrictions US National Differences according to CB Bulletin A T VRheinland www tuv com Page 112 of 112 Report No 16041780 001 IEC60950 1B ATTACHMENT National Differences Requirement Test Result Remark Annex NAD Equipment connected to a telecommunication No such equipment and cable distribution networks and supplied with an earphone intended to be held against or in the ear is required to comply with special acoustic pressure requirements Verdict Annex NAF
119. s taken of the background level Replace the notes as follows NOTE These values appear in Directive 96 29 Euratom Delete NOTE 2 N A Bibliography Additional EN standards ZA Normative references to international publications with their corresponding European publications ZB Annex 1 2 4 1 Special National Conditions EN In Denmark certain types of Class appliances Appliances inlet used see 3 2 1 1 may be provided with a plug not establishing earthing conditions when inserted into Danish socket outlets N A 1 2 13 14 1 5 7 1 1 5 8 1 5 9 4 In Norway and Sweden for requirements see No such construction 1 7 2 1 and 7 3 of this annex In Finland Norway and Sweden resistors No such resistor bridging BASIC INSULATION in CLASS PLUGGABLE EQUIPMENT TYPE A must comply with the requirements in 1 5 7 1 In addition when a single resistor is used the resistor must withstand the resistor test in 1 5 7 2 In Norway due to the IT power system used see annex V Figure V 7 capacitors are required to be rated for the applicable line to line voltage 230 V In Finland Norway and Sweden the third No such construction dashed sentence is applicable only to equipment as defined in 6 1 2 2 of this annex N A N A N A www tuv com 1 7 2 1 Page 67 of 112 In Finland Norway and Sweden CLASS I PLUGGABLE EQUIPMENT TYPE A i
120. s to IEC 60950 1 2001 1st Edition for explanation of codes see below AU Explanation of used codes AU Australia Summary of compliance with National Differences to IEC 60950 1999 for explanation of codes see below CN Explanation of used codes CN China All country differences listed in the CB Bulletin are covered by common Modifications Special National Conditions National Deviations and National Requirements noted follows except for the following countries which are documented in Country Differences All national differences see corresponding pages Copy of marking plate The artwork below may be only a draft The use of certification marks on a product must be authorized by the respective NCBs that own these marks P Switching Power Supply MODEL WMS 200SFX ID A12 82020T ae VOLTAGE CURRENT INPUT 115 230V 50 60Hz OUTPUT CAUTION HAZARDOUS AREA SAFETY INSTRUCTIONS DO NOT REMOVE THE COVER NO SERVICEABLE COMPONENTS INSIDE REFER SERVICING TO QUALIFIED PERSONNEL WARRANTY VOID IF SEAL REMOVED OR DAMAGED S N WK081102P MADE IN CHINA TRF No IEC60950 1B A TUVRheinland www tuv com Page 5 of 112 Report No 16041780 001 E Switching Power Supply MODEL WMS 250SFX ID A12 82525T o CURRENT FREQUENCY mos 15230 5A rer AE T er OUTPUT CAUTION HAZARDOUS AREA SAFETY INSTRUCTIONS DO NOT REMOVE THE COVER NO SERVICEABLE COMPONENTS INSIDE REFER SERVICING TO Q
121. secondary circuits See 5 3 4 P 2 10 3 5 Clearances in circuits having starting pulses No such circuit N A 2 10 3 6 Transients from a c mains supply See 2 10 3 2 N A 2 10 3 7 Transients from d c mains supply N A 2 10 3 8 Transients from telecommunication networks and No TNV circuit N A cable distribution systems 2 10 3 9 Measurement of transient voltage levels See 2 10 3 6 N A a Transients from a mains suplply N A For an a c mains supply ssssssssss N A For a d c mains supply eee eee eee tees N A b Transients from a telecommunication network N A 2 10 4 Creepage distances See below P 2 10 4 1 General see appended table 2 10 3 P and 2 10 4 2 10 4 2 Material group and caomparative tracking index P CTI tests inopi e eee eene rie 3 CTI rating for all materials of min 100 2 10 4 3 Minimum creepage distances see appended table 2 10 3 P and 2 10 4 2 10 5 Solid insulation P 2 10 5 1 General See below P 2 10 5 2 Distances through insulation Opto coupler provided P see appended table 2 10 5 2 10 5 3 Insulating compound as solid insulation No such component N A 2 10 5 4 Semiconductor devices No such component N A 2 10 5 5 Cemented joints No such construction N A 2 10 5 6 Thin sheet material General Insulation tapes provided P reinforced insulation used in T1 T2 between the primary and seco
122. sformer used N A 2 10 1 6 Special separation requirements No TNV N A 2 10 1 7 Insulation in circuits generating starting pulses No such circuit N A 2 10 2 Determination of working voltage The rms and the peak voltage P were measured on the EUT The unit was connected to a 240Vac power supply and floating secondary circuits was assumed to be earthed at the point by which the highest working voltage is obtained Results see appended table 2 10 2 2 10 2 1 General See above P 2 10 2 2 RMS working voltage Results see appended table P 2 10 2 2 10 2 3 Peak working voltage Results see appended table P 2 10 2 2 10 3 Clearances See below and advantage of P annex G is not considered 2 10 3 1 General See below Annex G was not P considered 2 10 3 2 Mains transient voltages See below P a AC mains supply ene Normal transient voltage P considered overvoltage category II for primary circuit b Earthed d c mains supplies AC mains N A c Unearthed d c mains supplies N A d Battery Operation eeeeeeees N A 2 10 3 3 Clearances in primary circuits Annex F and minimum P clearances considered see appended table 2 10 3 and 2 10 4 TRF No IEC60950 1B A TUVRheinland www tuv com Page 19 of 112 Report No 16041780 001 IEC 60950 1 Clause Requirement Test Resut Remak Verdict 2 10 3 4 Clearances in
123. stribution system using coaxial cable may in some circumstances create a fire hazard Connection to a cable distribution system has therefore to be provided through a device providing electrical isolation below a certain frequency range galvanic isolator see EN 60728 11 IEC60950_1B ATTACHMENT National Differences Requirement Test A T VRheinland Report No 16041780 001 Result Remark Verdict Appliance inelt used Should be considered during national approval N A N A www tuv com Requirement Test A T VRheinland Page 68 of 112 Report No 16041780 001 IEC60950 1B ATTACHMENT National Differences Result Remark Verdict 1 7 5 2 2 4 2 3 2 2 3 4 2 6 3 3 NOTE In Norway due to regulation for installations of cable distribution systems and in Sweden a galvanic isolator shall provide electrical insulation below 5 MHz The insulation shall withstand a dielectric strength of 1 5 kV r m s 50 Hz or 60 Hz for 1 min Translation to Norwegian the Swedish text will also be accepted in Norway Utstyr som er koplet til beskyttelsesjord via nettplugg og eller via annet jordtilkoplet utstyr og er tilkoplet et kabel TV nett kan for rsake brannfare For unng dette skal det ved tilkopling av utstyret til kabel TV nettet installeres en galvanisk isolator mellom utstyret og kabel TV nettet Translation to Swedish Utrustning
124. t Remark Verdict Main SI Tech Corp Ltd El 33 Pri Winding Applicable parts in Test with Transformer N1 Pin 4 3 IEC 60950 1 and appliance T1 RO ATUM Px19 acc to IEC 60085 S N4 Pin 3 2 0 7mx1Px19Ts Sec Winding N2 Pin 11 12 7 8 00 8mmx4Px3T S N3 Pin 9 7 8 0 8mmx3Px7T S Class B Chang Chun T375J PF V 0 150 C Plastics Co Ltd min Thickness 0 5mm Insulation Chyun Yih Tape P2981F 130 C 5 UL E81174 Tape Co Ltd Varnish Wu Jiang Taihu T4260P Minimum 130 C UL E228349 Insulating Material Co Ltd Stand by SI Tech Corp Ltd EEL 19 Pri Winding Applicable parts in Accepted by Transformer N1 Pin 10 8 IEC 60950 1 and TUV T2 0 21mmx1Px7 acc to IEC 60085 Rheinland 5Ts N3 Pin 5 6 o0 4mmx1Px30 Ts N4 Pin 5 7 o0 3mmx1Px1 1 Ts N5 Pin 8 9 0 21mmx1Px7 5Ts Sec Winding N2 Pin 2 4 0 4mx3Px9Ts Class B Chang Chun T375J PF V 0 150 C UL E59481 Plastics Co Ltd min Thickness 0 5mm Insulation Chyun Yih Tape P2981F 130 C 2 UL E81174 Tape Co Ltd UL E59481 TRF No IEC60950 1B www tuv com Page 44 of 112 A TUVRheinland Report No 16041780 001 IEC 60950 1 Clause Requirement Test Result Remark Verdict Varnish Wu Jiang Taihu ra2 60P Minimum 130 Minimum 130 C I fu E228349 Insulating Material Co Ltd Mylar Sheet Dupont Teijin Mylar MO31 VTM 2 or better UL E93687
125. t in the equipment 1 5 3 Thermal controls N A 1 5 4 Transformers Transformer used are suitable P for their intended application and comply with the relevant requirements of the standard and particularly Annex C 1 5 5 Interconnecting cables N A 1 5 6 Capacitors bridging insulation Between the primary circuits P and protective earth circuits capacitors subclass Y2 according to IEC 60384 14 Between the line and neutral capacitors subclass X2 according to IEC 60384 14 1 5 7 Resistors bridging insulation P 1 5 7 1 Resistors bridging functional basic or supplementary Bleeder resistor R1 loacted P insulation between L and N after current fuse 1 5 7 2 Resistors bridging double or reinforced insulation N A between a c mains and other circuits 1 5 7 3 Resistors bridging double or reinforced insulation N A TRF No IEC60950 1B www tuv com Page 10 of 112 A T VRheinland Report No 16041780 001 IEC 60950 1 Clause Requirement Test Result Remark Verdict 1 5 8 Components in equipment for IT power systems P 1 5 9 Surge suppressors No VDR used N A 1 5 9 1 General N A 1 5 9 2 Protection of VDRs N A 1 5 9 3 Bridging of functional insulation by a VDR N A 1 5 9 4 Bridging of basic insulation by a VDR N A 1 5 9 5 Bridging of supplementary double or reinforced N A insulation by a VDR 1 6 Power interface 1 6 1 AC power distribution systems IT power system for Norway only TN po
126. t connection mains supply by a power supply cord is not equipment permitted except for certain equipment such as ATMs 3 2 5 Power supply cords are required to be no No power cord provided longer than 4 5 m in length and minimum length shall be 1 5 m Flexible power supply cords are required to be compatible with Article 400 of the NEC Permanently connected equipment must have Not permanent connection a suitable wiring compartment and wire equipment bending space 3 3 3 Wire binding screws are not permitted to attach No terminals for permanent conductors larger than 10 AWG 5 3 mm wiring 3 3 4 Terminals for permanent wiring including Inlet used protective earthing terminals must be suitable for U S wire gauge sizes rated 125 percent of the equipment rating and be specially marked when specified 1 7 7 Motor control devices are required for cord No motor connected equipment with a motor if the equipment is rated more than 12 A or if the motor has a nominal voltage rating greater than 120 V or is rated more than 1 3 hp locked rotor current over 43 A Vertically mounted disconnect switches and Built in equipment should be circuit breakers are required to have the on considered end system position indicated by the handle in the up position For computer room applications equipment Not computer room with battery systems capable of supplying 750 applications VA for five minutes are required
127. t on the market Of this requirement rules for use even only by SERVICE PERSONS are not exempted No switch provided Appliance inlet used Built in equipment N A N A N A www tuv com Page 75 of 112 A TUVRheinland Report No 16041780 001 IEC60950 1B ATTACHMENT National Differences Requirement Test Result Remark Verdict According to GPSG section 2 clause 4 If certain rules on the use supplementation or maintenance of an item of technical work equipment or ready to use commodity must be observed in order to guarantee safety and health instructions for use in German must be supplied when it is brought into circulation N A Denmark Heavy Current Regulations With the exception of CLASS Il EQUIPMENT provided with a socket outlet in accordance with the Heavy Current Regulations Section 107 2 D1 Standard Sheet DK 1 4a CLASS II EQUIPMENT shall not be fitted with socket outlets for providing power to other equipment Switzerland Ordinance on chemical hazardous risk reduction SR 814 81 Annex 2 15 Batteries Annex 2 15 of SR 814 81 applies for batteries Denmark Heavy Current Regulations Chapter 707 clause 707 4 TOUCH CURRENT measurement results exceeding 3 5 mA r m s are permitted only for PERMANENTLY CONNECTED EQUIPMENT and PLUGGABLE EQUIPMENT TYPE B No socket outlet provided No battery provided No such high touch current N
128. table at 2 4A 2 15 increase to 2 5A unit shut down 2 22 except 5Vsb Maximum 0 18 temperature was T1 coil 90 8 C T1 core 87 7 C T2 coil 84 4 C T2 core 83 3 C Ambient 26 6 C no damage no hazards 5Vsb o 253Vac 3 5hrs F1 0 18 Temperature was stable at 3 9A 0 23 increase to 4 1A unit shut down 0 28 immediately Maximum 0 03 temperature was T1 coil 39 0 C T1 core 37 5 C T2 coil 121 8 C T2 core 110 1C Ambient 26 6 C no damage no hazards Fan Stall 253Vac 2 0hrs F1 2 07 Unit shut down except 5Vsb 0 18 Maximum temperature were T1 coil 90 0 C T1 core 89 0 C T2 coil 84 6 C T2 core 82 6C Ambient 26 6 C no damage no hazards www tuv com Page 60 of 112 A TUVRheinland Report No 16041780 001 IEC 60950 1 Requirement Test Result Remark Verdict cracked repeat ten times TRF No IEC60950 1B Supplementary information 253Vac Opening Blocked 253Vac 2 0hrs F1 2 07 Unit shut down except 5Vsb 0 18 Maximum temperature were T1 coil 102 2 C T1 core 100 3 C T2 coil 94 9 C T2 core 94 3 C Ambient 26 5 C no damage no hazards Voltage Voltage 253V gt 1sec F1 2 07 Q1 Q2 damage no hazards select mismatch 126 5V 0 08 repeat two times total three switch times the same result came out no hazards Voltage Voltage 126 5V 1sec F1 Fuse open immediately no select mismatch gt 253V hazar
129. the additional testing shall be performed on all the test specimens as described in EN 60384 14 the impulse test of 2 5 kV is to be performed before the endurance test in EN 60384 14 in the sequence of tests as described in EN 60384 14 In Finland Norway and Sweden the exclusions No TNV are applicable for PERMANENTLY CONNECTED EQUIPMENT PLUGGABLE EQUIPMENT TYPE B and equipment intended to be used in a RESTRICTED ACCESS LOCATION where equipotential bonding has been applied e g in a telecommunication centre and which has provision for a permanently connected PROTECTIVE EARTHING CONDUCTOR and is provided with instructions for the installation of that conductor by a SERVICE PERSON In Finland Norway and Sweden for Not connected to cable requirements see 6 1 2 1 and 6 1 2 2 of this distribution system annex The term TELECOMMUNICATION NETWORK in 6 1 2 being replaced by the term CABLE DISTRIBUTION SYSTEM In Norway and Sweden for requirements see Not connected to cable 1 2 13 14 and 1 7 2 1 of this annex distribution system In Norway for installation conditions see EN Not connected to cable 60728 11 2005 distribution system Result Remark Verdict N A N A N A N A N A www tuv com Page 74 of 112 A TUVRheinland Report No 16041780 001 IEC60950_1B ATTACHMENT National Differences Requirement Test Result Remark Verdict A DEVIATIONS informative Sweden O
130. uirement Test Result Remark Verdict AfterL1 o l 253Vac 4 0hrs F1 2 07 Temperature was stable at 5 6A T1 Pin 2 20 gt increase to 6 6A unit shut down 7 8 4 3 3V 2 25 gt except 5Vsb Maximum transformer 0 18 temperature was T1 coil overload 91 4 C T1 core 89 3 C T2 coil 86 3 C T2 core 86 1 C Ambient 27 8 C no damage no hazards Output with normal load After L2 o l 253Vac 4 0hrs F1 2 07 gt Temperature was stable at 5A T1 Pin 2 22 increase to 6 2A unit shut down 7 8 5V 2 30 gt except 5Vsb Maximum transformer 0 18 temperature was T1 coil overload 97 8 C T1 core 97 1 C T2 coil 81 2 C T2 core 78 0 C Ambient 27 8 C no damage no hazards Output with normal load After L2 o l 253Vac 3 5hrs F1 2 07 Temperature was stable at 4A T1 Pin 2 26 gt increase to 5 8A unit shut down 7 8 412V 2 45 gt except 5Vsb Maximum transformer 0 18 temperature was T1 coil overload 97 7 C T1 core 94 9 C T2 coil 85 5 C T2 core 84 9 C Ambient 26 9 C no damage no hazards Output with normal load After L2 o l 253Vac 3 8hrs F1 2 07 gt Temperature was stable at 1 9A T1 Pin 7 8 2 15 gt increase to 2 0A unit shut down 12V 2 22 gt except 5Vsb Maximum transformer 0 18 temperature was T1 coil overload 91 9 C T1 core 87 0 C T2 coil 86 2 C T2 core 85 4 C Ambient 26 9 C no damage no hazards Output with normal lo
131. uits L2 pin 1 2 Shorted Unit shut down except 5Vsb V peak or V d c L2 pin 1 2 Shorted Unit shut down except 5Vsb L2 pin 1 2 Shorted Unit shut down except 5Vsb 2 4 2 TABLE limited current circuit measurement N A Location Voltage Current Freq Limit Comments mA Hz mA Note s No Y1 cap used 2 5 TABLE limited power sources N A Circuit output tested Measured Uoc V with all load circuits disconnected Normal condition VA Abnormal condition TRF No IEC60950 1B www tuv com Page 48 of 112 A TUVRheinland Report No 16041780 001 IEC 60950 1 Requirement Test Result Remark Verdict supplementary information Test voltage 253V Test frequency 60 Hz Location PE pin of inlet to metal chassis PE pin of inlet to metal chassis Note s 2 6 3 4 TABLE Ground continue test P Resistant measured Q Comments 32A 2 minutes 40A 2 minutes 2 10 2 Table working voltage measurement P Location For model WMS 250SFX Transformer T1 RMS voltage V Peak voltage V Comments TRF No IEC60950 1B T1 Pin 2 T1 Pin 7 8 183 468 T1 Pin 4 T1 Pin 7 8 183 436 T1 Pin 2 T1 Pin 9 208 464 Maximum Vrms T1 Pin 4 T1 Pin 9 163 448 T1 Pin 2 T1 Pin 11 12 193 480 Maximum Vpeak T1 Pin 4 T1 Pin 11 12 174 424 T2 Pin 5 T2 Pin 2 224 372 T2 Pin 5 T2 Pin 4 22
132. urn isolated from earth N A W 2 3 Common return connected to protective earth N A X ANNEX X MAXIMUM HEATING EFFECT IN TRANSFORMER TESTS see clause N A C 1 X1 Determination of maximum input current N A X 2 Overload test procedure N A Y ANNEX Y ULTRAVIOLET LIGHT CONDITIONING TEST see 4 3 13 3 N A Y 1 Test apparatus 2 eR Ree N A Y 2 Mounting of test samples eet N A Y 3 Carbon arc light exposure apparatus N A Y 4 Xenon arc light exposure apparatus N A Z ANNEX Z OVERVOLTAGE CATEGORIES see 2 10 3 2 and Clause G 2 N A AA ANNEX AA MANDREL TEST see 2 10 5 8 N A TRF No IEC60950_1B A TUVRheinland www tuv com Page 38 of 112 Report No 16041780 001 IEC 60950 1 Clause Requirement Test Verdict BB ANNEX BB CHANGES IN THE SECOND EDITION cc ANNEX CC Evaluation of integrated circuit IC current limiters N A CC 1 General N A CC 2 Test program 1 N A CC 3 Test program 2 N A DD ANNEX DD Requirements for the mounting means of rack mounted N A equipment DD 1 General N A DD 2 Mechanical strength test variable N N A DD 3 Mechanical strength test 250N including end N A STOPS eer T E DD 4 Complian e m err Rr EA N A EE ANNEX EE Household and home office document media shredders N A EE 1 General N A EE 2 Markings and instructions N A Use of markings or symbols ee N A Informat
133. w tuv com Page 32 of 112 Report No 16041780 001 IEC 60950 1 Clause Requirement Test Resut Remak Verdi A ANNEX A TESTS FOR RESISTANCE TO HEAT AND FIRE N A A 1 Flammability test for fire enclosures of movable N A equipment having a total mass exceeding 18 kg and of stationary equipment see 4 7 3 2 A 1 1 Samlples 3 nmn etel ite Wall thickness mm eeeeeesst A 1 2 Conditioning of samples temperature C N A A 1 3 Mounting of samples se N A A 1 4 Test flame see IEC 60695 11 3 N A Flame A B Gor D ecd A 1 5 Test procedure N A A 1 6 Compliance criteria N A Sample 1 burning time s ssssst Sample 2 burning time s ssssst Sample 3 burning time s ssssst A 2 Flammability test for fire enclosures of movable equipment having a total mass not N A exceeding 18 kg and for material and components located inside fire enclosures see 4 7 3 2 and 4 7 3 4 A 2 1 Samples material eet Wall thickness mm eeeeeset A 2 2 Conditioning of samples temperature C N A A 2 3 Mounting of samples se N A A 2 4 Test flame see IEC 60695 11 4 N A Flame A B Or GO secs chit en hel Gt A 2 5 Test procedure N A A 2 6 Compliance criteria N A Sample 1 burning time s ssssst Sample 2 burning tim
134. wer system for others 1 6 2 Input current Highest load according to 1 2 2 1 for this equipment is the operation with the max specified DC load see appended table 1 6 2 1 6 3 Voltage limit of hand held equipment Not hand held equipment 1 6 4 Neutral conductor Class equipment The neutral P is not identified in the equipment Double or reinforced insulation for rated voltage between accessible parts and primary phases 1 7 Marking and instructions 1 7 1 Power rating and identification markings 1 7 1 1 Power rating marking See below P Multiple mains supply connections N A Rated voltage s or voltage range s V See model list P Symbol for nature of supply for d c only Mains from AC source N A Rated frequency or rated frequency range Hz 50 60Hz P Rated current mA or A sss See model list P 1 7 1 2 Identification markings See below P Manufacturer s name or trade mark or identification Only trademark P DES SERERE ELEISON DERE ULIM PAS is shown on the label Model identification or type reference See model list P TRF No IEC60950 1B www tuv com Page 11 of 112 A T VRheinland Report No 16041780 001 IEC 60950 1 Clause Requirement Test Result Remark Verdict Symbol for Class II equipment only Class equipment N A Other markings and symbols
135. without any kind of digital processing of the sound signal that are brought to the market before the end of 2015 For equipment which is clearly designed or intended for use by young children the limits of EN 71 1 apply A T VRheinland www tuv com Page 80 of 112 Report No 16041780 001 IEC60950_1B ATTACHMENT National Differences Clause Requirement Test Result Remark Verdict Zx 2 No safety provision is required for equipment that N A complies with the following equipment provided as a package personal music player with its listening device where the acoustic output Laea ris lt 85 dBA measured while playing the fixed programme simulation noise as described in EN 50332 1 and a personal music player provided with an analogue electrical output socket for a listening device where the electrical output is lt 27 mV measured as described in EN 50332 2 while playing the fixed programme simulation noise as described in EN 50332 1 Zx 3 The warning shall be placed on the equipment or N A on the packaging or in the instruction manual and shall consist of the following the symbol of Figure 1 with a minimum height of 5 mm and the following wording or similar To prevent possible hearing damage do not listen at high volume levels for long periods Alternatively the entire warning may be given through the equipment display during use when the user is asked to acknowledge act
136. ying of flammable gas INADVERTENT REACTIVATION Any safety interlock which can be operated by means of the test finger Figure JA 1 is considered to cause reactivation of the hazard Compliance is checked by inspection and where necessary by a test with the test finger Figure JA 1 Added Not Document shredding machines N A Dimensions in millimeters Figure JA 1 Test finger Japanese Deviations for J60950 1 H22 2009 MITI Ordinance Clause 2 A T VRheinland www tuv com Page 105 of 112 Report No 16041780 001 IEC60950 1B ATTACHMENT National Differences Clause Requirement Test Result Remark Verdict JA 3 ISOLATING SWITCH Added N A Not Document shredding Document shredding machines shall incorporate machines an isolating switch complying with sub clause 3 4 2 as the device disconnecting the power of hazardous moving parts For this switch two position single use switch or multi position multifunction switch e g slide switch may be used If two position switch the positions for ON and OFF shall be indicated in accordance with sub clause 1 7 8 If multi position switch the position for OFF shall be indicated in accordance with sub clause 1 7 8 and other positions shall be indicated with proper terms or symbols Compliance is checked by inspection JA 4 PROTECTION IN OPERATOR ACCESS AREAS Added N A Not Document shredding