1. L l 1 A 1 2 3 4 5 7 8 9 t2 13 14 15 46 17 18 HH 2 n gt C ALPHA ALPHA BOM SPL e p lt Fig 5 Fig 6 ALPHA SCA ALPHA BOM d ALPHA F 41 1 ALPHA BOM 10 1112 13 44 15 16 17 18 415 1 mm ET ALPHA 2 CH R Ho E ALPHA BOM n ME z 10 11 12 13 14 15 16 17 18 Y Y ALPHA ALPHA BOM Ver 06 25 Fig 7 Contatti Contacts Contacts Kontakte Contactos Contatos lt lt UNITRC Contatti Contacts Contacts Kontakte Contactos O Contatos S UNIFLAT Contatti Contacts Contacts Kontakte Contactos Contatos Programmatore palmare universale Universal palmtop programmer Programmateur de poche universel Universellen Palmtop Programmierer Programador de bolsillo universal Programador palmar universal UNIMITTO Contatti Contacts Contacts Kontakte Contactos Contatos BFT S P A Via Lago di Vico 44 36015 Schio VI Italy Tel 0039 445 696511 Fax 0039 445 6965
2. OFF Command not entered 7 TRIMMER ADJUSTMENT Fig 3 TCA Dip1 ON It is used to set the automatic closing time after which the gate closes automatically adjustable from O to 90 s TW Alpha Sets the motor working time from O to 90s after which the motors stop In the case where electrical limit switches are used add a few extra seconds after the gate leaf stopping time Alpha BOM Working time is fixed to 10s trimmer TW min inputs 7 8 and 19 20 are considered as OPEN and CLOSE inputs respectively trimmer TW max inputs 7 8 and 19 20 are considered as START and PEDESTRIAN inputs respectively 8 INTEGRATED RECEIVER TECHNICAL SPECIFICATION Receiver output channels output channel 1 if activated controls a START command output channel 2 if activated controls the excitation of the 2nd radio channel relay for 1s Transmitter versions which can be used all Rolling Code transmitters compatible with Eu ANTENNA INSTALLATION Use an antenna tuned to 433MHz For Antenna Receiver connection use RG8 coaxial cable The presence of metallic masses next to the antenna can interfere with radio reception In case of insufficient transmitter range move the antenna to a more suitable position 9 PROGRAMMING Transmitter storage can be carried out in manual mode or by means of the Universal palmtop programmer which allows you to create installations in the collective receivers mode as well as manag
3. ENGLISH INSTALLATION MANUAL 7 12 Closing limit switch N C If not used leave the bridge con nected 13 14 Output 24V supply to photocells or other devices 15 16 Output for gate open warning light outputor alternatively 2nd radio channel 17 18 Antenna input for radio receiver plug in board 17 signal 18 braid JP3 19 20 Alpha PEDESTRIAN input N O Alpha BOM PEDESTRIAN input N O with trimmer TW max CLOSE input N O with trimmer TW min WARNING the pedestrian function can be used provided that limit switches are fitted JP4 Radio receiver board connector 1 2 channels Fig 7 shows a general wiring diagram 5 LED Fig 3 The ALPHA ALPHA BOM control units are provided with a series of self diagnosis LEDs which control all the functions DL1 Incorporated radio receiver LED DL2 A pha comes on with the START command Alpha BOM START trimmer TW max comes on with the START command OPEN trimmer TW min comes on with the OPEN command DL3 STOP goes off when a STOP command is given DL4 PHOT Photocell goes off when the photocells are not aligned or in the presence of obstacles DL5 SWO Goes off when the opening limit switch is operated DL6 SWC Goes off when the closing limit switch is operated 6 DIP SWITCH SELECTION Fig 3 DIP1 TCA ON Automatic closing time TCA ON Activates automatic closing OFF Excludes automatic closing DIP2 FCH ON Photocells ON Photocells are only ac
4. Sicherheitsbedingungen der Direktiven Es conforme a los requisitos esenciales de seguridad de las Directivas Est conforme aos requisitos essenciais de seguran a das Directivas Indirizzo Address Adresse Adresse Direcci n Endere o BASSA TENSIONE LOW VOLTAGE BASSE TENSION NIEDERSPANNUNG BAJA TENSION BAIXA ENSAO 73 23 CEE 93 68 CEE EN60335 1 03 e modifiche successive and subsequent amendments et modifications successives und ihren nachfolgende nderungen e modifica es sucessivas y modificaciones sucesivas COMPATIBILIT ELETTROMAGNETICA ELECROMAGNETIC COMPATIBILITY COMPATIBILIT LECTROMAGN TIQUE ELEKTROMAGNETISCHE KOMPATIBILITAT COMPATIBILIDAD ELECTROMAGNETICA COMPATIBILIDADE ELECTROMAGN TICA 89 336 CEE 91 263 CEE 92 31 CEE 93 68 EN61000 6 1 EN61000 6 2 EN61000 6 3 EN61000 6 4 EN55014 1 EN55014 2 e modifiche successive and subsequent amendments et modifications successives und ihren nachfolgende nderungen e modifica es sucessivas y modificaciones sucesivas APPARECCHIATURE RADIO RADIO SETS INSTALLATIONS RADIO RADIOAPPARATE RADIOEQUIPOS RADIOAPARELHOS 99 5 CEE ETSI EN 301 489 3 2000 ETSI EN 301 489 1 2000 ETSI EN 300 220 3 2000 EN60950 e modifiche successive and subsequent amendments et modifications successives und ihren achfolgende nderungen e modifica es sucessivas y modificaciones sucesivas SCHIO 20 0
5. any time and without undertaking to update the present publication ALPHA ALPHA BOM Ver 06 3 e e e a ENGLISH INSTALLATION MANUAL Thank you for buying this product our company is sure that you will be more than satisfied with its performance This product is supplied with an Instruction Manual which should be read carefully as it provides important information about safety installation operation and maintenance This product complies with recognised technical standards and safety regulations We declarethatitis in conformity with the following European Directives 89 336 EEC 73 23 EEC and subsequent amendments 1 GENERAL SAFETY WARNING An incorrect installation or improper use of the product can cause damage to persons animals or things The Warnings leaflet and Instruction booklet supplied with this product should be read carefully as they provide important information about safety installation use and maintenance Scrap packing materials plastic cardboard polystyrene etc according to the provisions set out by current standards Keep nylon or polystyrene bags out of children s reach Keep the instructions together with the technical brochure for future reference This product was exclusively designed and manufactured for the use specified in the present documentation Any other use not specified in this documentation could damage the product and be dangerous The
6. green conductor of the power supply cable to the earth terminal 230V cables must be physically separate from the safety very low voltage circuits Keep the mains voltage connections definitely separate from the 24V very low voltage connections The capacitors inside the control unit must be positioned in such a way as not to decrease the surface and air distances with respect to the safety very low voltage WARNING For connection to the mains use a multipolar cable with a minimum of 3x1 5mm cross section and complying with the previously mentioned regulations For example if the cable is out side in the open it has to be at least equal to HO7RN F but if itis on the inside or outside but placed ina plastic cable cannel it has to be or at least egual to HO5VV F with section 3x1 5mm JP1 1 2 Power supply 230V 10 50 60 Hz Neutral to terminal 1 3 4 5 Connection to motor M terminal 4 common terminals 3 5 motor and capacitor drive 1 4 Connection to blinker and electric lock 230V mod EBP JP2 7 8 Alpha START or key selector input N O Alpha BOM START or key selector input N O with trimmer TW max OPEN input N O with trimmer TW min 7 9 STOP pushbutton N C If not used leave the bridge con nected 7 10 Photocell input or pneumatic edge N C If not used leave the bridge connected 7 11 Opening limit switch N C If not used leave the bridge con nected ALPHA ALPHA BOM Ver 06 9
7. luu ertt eret einer ree 230V 10 50Hz Mains insulation very low voltage gt 4MQ 500V Working temperature eese 10 55 Max motor power absorbed 500W Dielectric strength mains low voltage 3750V for 1 minute Gate open warning light 24V 3W max Supply to accessories 24V 0 2A max absorption Incorporated Rolling Code radio receiver Frequency 433 92MHz A e Rolling Code Algorithm to be cloned No combinations essen 4 milliard Antenna impedancoe 50Ohm RG58 Max no radio transmitters to be memorised 63 DIMENSIONS coser eei o see figure 1 other voltages available on request 4 TERMINAL BOARD CONNECTIONS Fig 2 For the electric diagram and the cross section of the cables refer to the manual of the actuator WARNING During the wiring and installation operations referto the current standards as well as principles of good technical practice Wires powered at different voltages must be physically separated or suitably insulated with at least 1 mm extra insulation The wires must be clamped by an extra fastener near the terminals for ex ample by bands All the connection cables must be kept at an adequate distance from the dissipator Connect the yellow
8. 22 www bft it e mail sales bft it BFT TORANTRIEBSSYSTEME GmbH Faber Castell Str 29 90522 Oberasbach Germany Tel 0049 911 7660090 Fax 0049 911 7660099 e mail service bft torantriebe de BFT AUTOMATION UK LTD Unit 8E Newby Road Industrial Estate Hazel Grove Stockport SK7 5DA England Tel 0044 161 4560456 Fax 0044 161 4569090 e mail info bft co uk AUTOMATISMES BFT FRANCE 13 Bdl E Michelet 69008 Lyon France Tel 0033 4 78 76 09 88 Fax 0033 4 78 76 92 23 e mail infofrance bft it BFT BENELUX SA Rue du commerce 12 1400 Nivelles Belgium Tel 0032 67 55 02 00 Fax 0032 67 55 02 01 mail info bftbenelux be BFT ADRIA d o o Obrovac 39 51218 Dra ice RIJEKA Croazia Tel 00385 51 502 640 Fax 00385 51 502 644 www bft hr e mail infoObft hr BFT Polska Sp z o o ul Szatwiowa 47 03 167 Warszawa Polska Tel 0048 022 814 12 22 Fax 0048 022 814 39 18 www bft com pl e mail biuro bft com pl BFT GROUP ITALIBERICA DE AUTOMATISMOS S L Espa a www bftautomatismos com P I Palau Nord Sector F C Cami Can Basa n 6 8 08400 GRANOLLERS Barcelona Telf 34 93 8614828 Fax 34 93 8700394 e mail bftocn bftautomatismos com P I Comendador C inform tica Nave 22 19200 AZUQUECA DE HENARES Guadalajara Telf 34 949 26 32 00 Fax 34 949 26 24 51 e mail bft bftautomatismos com 26 ALPHA ALPHA BOM Ver 06 D811430 06
9. 6 2005 2 ALPHA ALPHA BOM Ver 06 D811430 06 D811430 06 ENGLISH USER S MANUAL Thank you for buying this product our company is sure that you will be more than satisfied with the product s performance The product is supplied with a Warnings leaflet and an Instruction booklet These should both be read carefully as they provide important information about safety installation operation and maintenance This product complies with the recognised technical standards and safety regulations We declare that it is in conformity with the follow ing European Directives 89 336 EEC 73 23 EEC and subsequent amendments 1 GENERAL OUTLINE The ALPHA ALPHA BOM mod control units have been designed to control one single operator 2 SCRAPPING Warning This operation should only be carried out by quali fied personnel Materials must be disposed of in conformity with the current regulations In case of scrapping the automation devices do not entail any particular risks or danger In case of materials to be recycled these should be sorted out by type electrical components copper aluminium plastic etc 3 DISMANTLING Warning This operation should only be carried out by qualified personnel Whenthecontrolunitisdisassembledtobereassembled on another site proceed as follows e Disconnect the power supply and the entire electrical installa tion In the case where some of the components c
10. Company declines all responsibility for any consequences resulting from improper use ofthe product or use which is different from that expected and specified in the present documentation Do not install the product in explosive atmosphere The construction components of this product must comply with the following European Directives 89 336 CEE 73 23 EEC 98 37 EEC and subsequent amendments As for all non EEC countries the above mentioned standards as well as the current national standards should be respected in order to achieve a good safety level The Company declines all responsibility for any consequences resulting from failure to observe Good Technical Practice when constructing closing structures door gates etc as well as from any deformation which might occur during use The installation must comply with the provisions set out by the following European Directives 89 336 CEE 73 23 EEC 98 37 EEC and subsequent amendments Disconnect the electrical power supply before carrying out any work on the installation Also disconnect any buffer batteries if fitted Fit an omnipolar or magnetothermal switch on the mains power supply having a contact opening distance equal to or greater than 3 5 mm Check that a differential switch with a 0 03A threshold is fitted just before the power supply mains Check that earthing is carried out correctly connect all metal parts for closure doors gates etc and all system com
11. D811430 ver 06 11 04 07 GB CONTROL PANEL x 8 92790811 240637 ALPHA ALPHA BOM INSTALLATION AND USER S MANUAL Via Lago di Vico 44 nn AZIENDA CON SISTEMA DI GESTIONE id upon EUM N j UEN ISO 2001 2000 Tel int 39 0445 696533 Fax 0445 696522 UNI EN ISO 14001 2004 Internet www bft it E mail sales blt it DICHIARAZIONE DI CONFORMIT DECLARATION OF CONFORMITY D CLARATION DE CONFORMIT KONFORMITATSERKLARUNG DECLARACION DE CONFORMIDAD DECLARAC O DE CONFORMIDADE Fabbricante Manufacturer Fabricant Hersteller Fabricante Fabricante S p a Via Lago di Vico 44 36015 Schio VICENZA ITALY e Dichiara sotto la propria responsabilit che il prodotto Declares under its own responsibility that the following product D clare sous sa propre responsabilit que le produit Erkl rt auf eigene Verantwortung da das Produkt Declara bajo su propia responsabilidad que el producto Declara sob a sua responsabilidade que o produto Centralina di comando mod Control unit mod Unit de commande mod Steuerzentrale mod Central de mando mod Central do mando mod ALPHA ALPHA BOM conforme ai requisiti essenziali di sicurezza delle Direttive It complies with the main safety requirements of the following Directives Est conforme aux exigences essentielles de s curit des Directives Es entspricht den grundlegenden
12. IVE RECEIVERS Make reference to the universal palmtop programmer Instructions and the CLONIX Programming Guide 13 ACCESSORIES SPL fig 4 Pre heating optional board Recommended for temperatures below 10 C In the case of hydraulic motors ME fig 5 Optional board used to connect a 12V electric lock Note the ME optional board is not operated by the START control of the integrated radio board For the correct functioning of the ME optional board use one of the following configurations 1 use the second radio channel as START control and perform the necessary connections to the terminal board 2 use the plug in radio receiver fig 2 The EBP electric lock with continuous service can be connected directly to terminals 1 and 4 14 SCRAPPING Warning This operation should only be carried out by qualified personnel Materials must be disposed of in conformity with the current regulations In case of scrapping the automation devices do not entail any particular risks or danger In case of materials to be recycled these should be sorted out by type electrical components copper aluminium plastic etc 15 DISMANTLING Warning This operation should only be carried out by qualified personnel Whenthe control unitis disassembled to be reassembled on another site proceed as follows Disconnect the power supply and the entire electrical installation nthe case where some of the components cannot be remo
13. LLATION MANUAL ENGLISH 11 RECEIVER CONFIGURATION 8 The on board receiver combines characteristics of utmost safety in copying variable code rolling code coding with the convenience of carrying out transmitter cloning operations thanks to an exclusive system Cloning a transmitter means creating a transmitter which can be automatically included within the list of the transmitters memorised in the receiver either as an addition or as a replacement of a par ticular transmitter Cloning by replacement is used to create a new transmitter which takes the place of the one previously memorised in the receiver in this way a specific transmitter can be removed from the memory and will no longer be usable Therefore it will be possible to remotely program a large number of additional transmitters or for example replacement transmitters for those which have been lost without making changes directly to the receiver When coding safety is not a decisive factor the on board receiver allows you to carry out fixed code additional cloning which although abandoning the variable code provides a high number of coding combinations therefore keeping it possible to copy any transmitter which has already been programmed 12 RADIO TRANSMITTER CLONING Fig 7 Rolling code cloning Fixed code cloning Make reference to the universal palmtop programmer instructions and the CLONIX Programming Guide 12 1 ADVANCED PROGRAMMING COLLECT
14. annot be removed or are damaged they must be replaced 4 WARNING Make sure that an omnipolar or magnetothermal switch having a contact opening distance equal to or greater than 3 5 mm is fitted to the automation power supply mains Makesurethata differential switch with a 0 03A threshold is fitted before the power supply mains Make sure that all safety devices installed on the gate are always in working order otherwise disconnectthe power supply release the motors and immediately request assistance from qualified personnel Donotallow persons or children to remain within the automation operation area Keepradiocontrolorothercontrol devices out of children s reach in order to avoid unintentional automation activation The user must avoid any attempt to carry out work or repair on the automation system and always request the assistance of qualified personnel Correct controller operation is only ensured when the data contained in the present manual are observed The company is not to be held responsible for any damage resulting from failure to observe the installation standards and the instructions contained in the present manual The descriptions and illustrations contained in the present manualarenotbinding The Companyreservestherightto make any alterations deemed appropriate for the technical manu facturing and commercial improvement of the product while leaving the essential product features unchanged at
15. e the complete installation database using the EEdbase software 10 MANUAL PROGRAMMING In the case of standard installations where no advanced functions are required it is possible to proceed to manual storage of the transmitters 1 you wish the transmitter T key to be memorised as Start press thSW1 button on the control unit otherwise if you wish the transmitter key to be memorise as second radio channel press the SW2 button on the control unit 2 When the DL1 LED blinks press the transmitter P1 hidden key and the DL1 LED will stay on permanently 3 Press the key to be memorised on the transmitter LED DL1 will start blinking again 4 To memorise another transmitter repeat steps 2 and 3 5 To exit the storage mode wait until the LED is switched off com pletely IMPORTANT NOTE ATTACH THE ADHESIVE KEY LABEL TO THE FIRST MEMORISED TRANSMITTER MASTER In the case of manual programming the first transmitter assigns the key code to the receiver this code is necessary in order to carry out subsequent cloning of the radio transmitters 10 1 CONTROL UNIT MEMORY CANCELLATION In order to cancel the control unit memory completely simultaneously press for 10 seconds the SW1 and SW2 buttons on the control unit DL1 LED blinking Correct memory cancellation will be indicated by the DL1 LED staying on permanently To exit the storage mode wait until the LED is switched off completely D811430 06 11430 06 INSTA
16. ponents provided with an earth terminal Fitallthe safety devices photocells electric edges etc which are neededto protectthe area from any danger caused by squashing conveying and shearing e Position atleastone luminous signal indication device blinker where it can be easily seen and fix a Warning sign to the structure The Company declines all responsibility with respect to the automation safety and correct operation when other manufacturers components are used Only use original parts for any maintenance or repair operation Do not modify the automation components unless explicitly authorised by the company Instruct the product user about the control systems provided and the manual opening operation in case of emergency Donotallow persons or children to remain in the automation operation area Keepradio control or other control devices out of children s reach in order to avoid unintentional automation activation The user must avoid any attempt to carry out work or repair on the automation system and always request the assistance of qualified personnel e Anything which is not expressly provided for in the present instruc tions is not allowed Installation must be carried out using the safety devices and controls prescribed by the EN 12978 Standard 2 GENERAL OUTLINE The ALPHA ALPHA BOM mod control units have been designed to control one single operator 3 TECHNICAL DATA Power SUpply
17. tive in the closing phase OFF Photocells are active both in the closing and opening phase DIP3 BLI Blocks impulses ON START commands are not accepted during the opening phase OFF START commands are accepted during the opening phase DIP4 3P 4P 3 Steps 4 Steps ON Enables 3 step logic OFF Enables 4 step logic DIP5 CODE FIX Fixed code ON Activates incorporated receiver in fixed code mode OFF Activates incorporated receiver in rolling code mode DIP6 RADIO LEARN Radio transmitter programming ON This enables transmitter storage via radio 1 Firstpress the hidden key P1 and then the normal key 1 T2 T3 or T4 of a transmitter already memorised in standard mode by means of the radio menu 2 Within 10s press the hidden key P1 and the normal key T1 T2 T3 or T4 of a transmitter to be memorised The receiver exits the programming mode after 10s other new transmitters can be entered before the end of this time This mode does not require access to the control panel OFF This disables transmitter storage via radio The transmitters are only memorised by means of manual programming DIP7 SCA Gate open warning light or 2nd radio channel OFF Activates relay output in Gate open warning light mode ON Activates relay output as 2nd radio channel DIP8 10 ALPHA ALPHA BOM Ver 06 FAST CLOSE ON Closesthe gate after photocell disengagement before waiting for the end of the TCA set
18. ved or are damaged they must be replaced The descriptions and illustrations contained in the present manual are not binding The Company reserves the right to make any alterations deemed appropriate for the technical manu facturing and commercial improvement of the product while leaving the essential product features unchanged at any time and without undertaking to update the present publication ALPHA ALPHA BOM Ver 06 17 Fig 1 Fig 2 S Z im JP1 e 1 L 2 n METER o o pl CY i z a r EBP e o JP2 7 I smm ALPHA NA STARTIOPEN ALPHA BOM 8 STOP NC 2Le 9 PHOT NC 10 SW O NC 11 SW C NC 12 OV 4 13 24V lt 14 2CH 15 a N 17 gt gt lt ANTENNA ar a ANTENNE 18 T ANTENNA _ 1 ANTENA ANTENNE ANTENNE JP3 v C I lt T PED ALPHA DET rem Y lt A A AA 20 0811430 06 24 ALPHA ALPHA Ver 06 D811430 06