Home
FCWnx_Global_Edition..
Contents
1. Inthe Run window click OK Provide the appropriate answers to prompts and click Next to continue During installation you are prompted with a few questions e Type of CCTV Interface Select Kalatel e Description or name for the interface Enter a description for this interface such as Main Building CCTV Note If multiple same type CCTV interfaces are installed on a single FCWnx network the description of each interface must be unique e COM port to which this interface is connected Select the COM port Click Install to complete the installation Once the installation is complete from the Control Panel select System Hardware tab Device Manager Ports Select the COM port you previously selected in the installation and provide identical settings for baud rate data bits parity stop bits and flow control as your CCTV Controller s setup When you are ready to launch the CCTV program you need to restart the FCWhnx services on this client Once the system is running log on to the computer as an FCWnx user and start the FCWnx application Log on to FOWnx and from the Application FCWnx 7 7 Global Edition Installation Manual Group pane Monitors and Controls group select Client Monitor You notice an entry for the CCTV you just installed For FCWnx 2 1 and EE 1 1 from the Administration menu select Client Management 13 To start the CCTV application you need to create CCTV alarms in the CCTV Alarm form f
2. command 1 Click Start and then click Run 2 At the Run window type lt computer name gt where lt computer name gt is the name of the First Time License computer If the computer is found you receive a window listing the shared folders on that computer similar to the following P optiplex l0 x File Edit view Favorites Tools Help ay Oak O F P Search Folders sox E Address optiplex z Go Name Comments t i E hppsc220 hp psc 2200 series Images 2 LicenseInfo Logs 2 My Documents 2 Replication Signature 2 Video a Printers and Faxes Shows installed printers and fax printers an EJ Scheduled Tasks Schedule computer tasks to run automatically If the computer is not found you receive a message similar to the following FCWnxServer xj Q WECWnxServer The network path was not Found 252 FCWnx 7 7 Global Edition Installation Manual Chapter 8 Installing Facility Commander Wnx Software on additional clients Installing Facility Commander Wnx Windows 7 Windows Vista or Windows XP Professional additional client computer Before you begin e Your Facility Commander Wnx system will not install unless minimum requiremens have been met Before you begin Preinstallation checklist on page 240 e Ifyou are installing on a non English operating system NET Framework must be installed in the appropriate language to the operating system you are installing You cannot install Facility Commander
3. Chapter 2 Windows Server 2003 2008 Standard and Enterprise Edition Server setup Windows Server 2008 13 Windows firewall 14 Windows Server 2003 14 Windows Server 2008 15 Adding the computer toa domain 15 Defining user accounts 16 Installing Microsoft SQL Server 17 Microsoft SQL Server 2005 17 Installing Microsoft SQL Server 2005 17 Install SQL 2005 Service Pack 3 26 Setting SQL Server Agent properties 26 Microsoft SQL Server 2005 communication configuration 26 Additional SQL Server 2005 configuration for Global Edition 27 Microsoft SQL Server 2008 29 Installing Microsoft SQL Server 2008 29 Install SQL 2008 Service Pack 1 35 Windows Server 2008 communication foundation HTTP activation 35 Windows Server 2008 Distributed File System Installation 36 Microsoft SQL Server 2008 communication configuration 36 Additional SQL Server 2008 configuration for Global Edition 37 Cluster environment 38 What s next 38 8 FCWnx 7 7 Global Edition Installation Manual Chapter 2 Windows Server 2003 2008 Standard and Enterprise Edition Server setup Preinstallation checklist To prepare your Windows 2003 or Windows 2008 server computer refer to this checklist of reminders Note If you purchased this system from UTC Fire amp Security these tasks were completed for you Meet minimum recommended hardware and software requirements Install the network card Configure the computer for the network Install Windows 2003 or Windows 2008 Server
4. Summary Once you have installed the Facility Commander Wnx software you will need to log on to the server computer and set a few parameters before beginning to create any controller records or credentials Review How to Get Started in the Facility Commander Wnx Help System for a recommended order of initial setup and configuration Content Facility Commander Wnx services overview 266 Accessing the Services form 266 Starting Facility Commander Wnx 269 Logging on 270 Accessing help 270 Defining additional user accounts 271 Adding yourself as an operator in Facility Commander Wnx 271 Initial setup of Facility Commander Wnx records 271 Setting e mail accounts 271 Changing the Facility Commander Wnx server computer name 272 Server Computer Name in System Properties 272 Server Computer name change using SPServer exe utility 273 Re creating a Microsoft SQL Server registration 275 FCWnx 7 7 Global Edition Installation Manual 265 Chapter 9 Logging on and configuring Facility Commander Wnx Facility Commander Wnx services overview Windows computers use special programs called services A service is a process that can automatically start when the system boots and remain running as a background process independently of anyone being logged in All computers running Facility Commander Wnx client software use five services e FCWhnx Diagnostics controls the diagnostic information log FCWnx Manager controls the communication to and
5. 10 Once the installation is complete from the Control Panel select System Hardware tab Device Manager and then Ports Select the COM port you previously selected in the installation and provide identical settings for baud rate data bits parity stop bits and flow control as your CCTV Controller setup 1 When you are ready to launch the CCTV program you need to restart the FCWnx services on this client 12 Once the system is running log on to the computer as an FOWnx user and start the FOWnx application Log on to FCWnx and from the Application Group pane Monitors and Controls group select Client Monitor You notice an entry for the CCTV you just installed 13 To start the CCTV application you need to create CCTV alarms in the CCTV Alarm form first Then you need to map the desired FCWnx alarm to CCTV on the Alarm form CCTV tab Configuring alarms on page 323 and Monitoring on page 337 322 FCWnx 7 7 Global Edition Installation Manual 14 To start your CCTV interface click Launch Client on the toolbar while the CCTV interface is selected This starts the program that communicates with your CCTV switcher Configuring alarms The communication between the FCWnx system and the Burle Allegiant system is bidirectional meaning that alarms are sent from FCWnx to the Burle Allegiant system and alarms are also sent from the Burle Allegiant system to the FCWnx system Alarms from the Burle Allegiant system
6. FCWnx WebService FCWnx WCF Service Note FCWnx API Service is used when an external system is sending or receiving transactions by way of an Application Program Interface API to FCWnx When all services are configured close all windows and applications Restart the Facility Commander Wnx server computer Continue with Server folder structure on page 110 FCWnx 7 7 Global Edition Installation Manual 189 Chapter 4 Install Global Edition Regional configuration Server folder structure During installation of the Facility Commander Wnx software the folders shown in Figure 114 and listed in Table 20 are created The folders displayed in your FCWhnx folder the default is Program Files GE FCWnx vary with the type of installation If Typical Server type is selected all folders are present If Custom Server Type is installed and only the Database server feature is installed the following folders are present e Database e SecureScripts e gmcNis vmcNis e Logs File server feature is installed the following folders are present e Designs e gmcNls e Externals e Logs e Firmware e Video e vmcNis FCWnx client application is installed the following folders are present Config e Logs e English e Rpt gmcNis e UserManuals e GraphicsCache VideoSubsystem e jre e Vme e Vmenls Some of the folders are shared Refer to the example in Figure 61 on page 111 This allows other computers to gain access t
7. Selecting Installation Type of your FCWnx Installation Guide and proceed with complete FCWnx installation instructions Note Return to this point when the entire installation process is complete Following installation of FCWnx on a computer with Thin Client services enabled a manual restart is required to complete the process Restart your computer at this time and then proceed to log on Following installation of FCWnx 1 Log on to the FCWnx application Select the File menu and then Login For additional details review Chapter 9 Logging on and configuring Facility Commander Wnx on page 265 There are additional system parameters you need to address 2 Enter your login ID and password Note Default login ID is secure and the password is SecurityMaster08 case sensitive The language is English If logging into FCWnx using a client you must have a valid operating system Windows XP Professional or Vista user name and password along with a valid FCWnx login ID and password on the server computer Those login IDs must be part of the SPAdmin local group on the FCWnx server computer 304 FCWnx 7 7 Global Edition Installation Manual Appendix B Optional hardware and software 3 Click OK 4 Select the Administration menu Client option to open the Client form The Client form opens with the Client tab displayed 5 In the Thin Client Status combination group select Enabled Thin Client Terminal Server instal
8. The Facility Commander Wnx introduction page opens Click Install A series of windows may display as the listed components automatically install if not already there These components may cause the system to restart when a new version is installed If your computer restarts log on as Administrator and installation continues e NET Framework Windows Installer Note On rare occasions when installing Facility Commander from a DVD drive the installation will stall for approximately 10 to 20 minutes from the time you click Install to the time when the Welcome to Facility Commander Wnx 7 7 Installation Wizard page opens If this occurs it is most likely caused by your anti virus software If you have anti virus software running you must configure it so that the DVD drive is not scanned Refer to the documentation that came with your anti virus software for details The Facility Commander Wnx installation processes updates on your system When the latest versions of each component are updated and identified Facility Commander Wnx installation begins and the Welcome window opens Continue with Facility Commander Wnx software installation begins on page 77 Facility Commander Wnx software installation begins Note A Cancel button displays on every FCWnx installation window If you click Cancel at any time during the installation the FCWnx installation process stops but all Windows components that have been installed must be
9. boca com Replication Comments FC Whnx Replication Share Share to be used Replication lt Back Cancel 7 On the Root name window e Inthe Root name field enter Replication Enter FCWnx Replication Share in the Comment dialog box 8 Click Next The Root Share window opens In the Folder to Share click Browse and select a folder for file replication Click Next 9 The Completing the New Root Wizard window opens all settings as configured 10 Review the settings If you need to change an entry due to discrepancies click Back to return to the appropriate window and correct the incorrect entry or you can click Cancel to exit the Wizard and begin the process again 11 When all settings are accurate click Finish to close the Wizard 12 The Distributed File System snap in displays similar to Figure 124 FCWnx 7 7 Global Edition Installation Manual 205 Chapter 5 Configuring Global Edition for file replication Figure 124 Distributed File System Snap In with the Replication Dfs Root A Distributed File System File Action View Help e 2 m k ho s Distributed File System 8 boca com Replication gJ TESTiReplication Enabled Number of links 0 displayed 0 total Creating a New Dfs Link The actual configuration of file shares takes place when you create the Dfs links Note Complete this section for each FCWnx file share to be created To create the Dfs link 1 Right cl
10. 5 Click Start to start the service 6 Click Apply and then OK to close the window 7 Close the Services window Creating Dfs Root The Domain Distributed File System provides file replication to the FCWnx shared folders called Dfs Root replicas To create Distributed File System Root 1 Select Start Programs Administrative Tools and then Distributed File System The Distributed File System snap in opens as shown in the folder structure in Figure 119 FCWnx 7 7 Global Edition Installation Manual 201 Chapter 5 Configuring Global Edition for file replication Figure 119 Distributed Files System Snap in A Distributed File System D Distributed File System By using Distributed File System DFS you can organize multiple shared folders or targets into a logical namespace of roots and links You can also use DFS to control how File Replication service replicates Files between those targets To show an existing DFS root click Action and then click Show Root To create a DFS root click Action and then click New Root 2 Right click Distributed File System to display a shortcut menu Select New Root The New Root Wizard window opens 3 Click Next The Root Type window opens as shown in Figure 120 Figure 120 Root Type New Root Wizard Root Type You can create a domain or a stand alone root 202 FCWnx 7 7 Global Edition Installation Manual Chapter 5 Configuring Global
11. Interfaces then CCTV Interface Click Search Inthe Search Result window locate and then select the CCTV alarm you want to delete Click Delete FCWnx 7 7 Global Edition Installation Manual 5 You are prompted to verify your decision to delete Click Yes to delete or No to keep the record Mapping FCWnx alarms to CCTV alarms Before you begin make sure that you have e Added CCTV alarms see previous section e Configured the micros so that you have FCWnx alarms to map refer to the Online help for assistance To map FCWnx alarms to CCTV alarms 1 From the FCWnx Application Group pane select Gateways amp Interfaces then CCTV Interface 2 Click Search Inthe Search Result window locate and then select the FCWnx alarm you want to map The alarm information now displays Select the CCTV tab Click Add Remove The CCTV alarms you added in the previous step display oo Select the desired CCTV alarm you would like to map to the FCWnx alarm oOo N OO Ff Click to assign an alarm If you would like to unassign one select the desired CCTV alarm from the list on the right and click 9 When you are done assigning alarms click OK 10 Click the Alarm tab Verify that the Monitor field is enabled 11 Click Save Monitoring When you added CCTV alarms the Reset CCTV Alarm field provided two reset choices for the alarm when the alarm is cleared from the Alarm Monitor or when the alarm
12. The following port numbers are read from the dvmrtable of your FCWnx system 8088 Server Workstation Video Streaming Port Used by the video server to send streaming video 8085 Start Video Communications Port Range 3 Used by video clients to communicate with video servers 8089 Start Digital Video Viewer Port Range 20 Additional ports used by video clients to communicate with video servers These numbers signify a range of ports Your application log identifies the specific ports that are opened Additionally your firewall application identifies which ports are on or off 236 FCWnx 7 7 Global Edition Installation Manual Chapter 9 License and Set Security Settings for your FCWnx System 13 Accept the default port settings or enter another setting If you change any setting you are opening firewall ports and changing how video communicates e If any port range setting is changed the previously opened firewall port is closed the next time that SecurityCnfg is run For example the first time SecurityCnfg is run you accept the default settings You run SecurityCnfg again and change the port numbers the old port numbers will be closed and the new ones will be opened e Ports are usually changed because they are in use by other applications Closing the ports in the firewall affects these applications e It is required that each computer in your FCWnx system be changed to the identical setting e Then restart servic
13. This may take a few minutes 12 When the Facility Commander Wnx has been successfully installed window opens click Finish 13 If your computer restarts log on and continue Creating the database custom installation To install the Global database server 1 A Select Database Server Type window opens as shown in Figure 37 Select Global Database Server and click Next 72 FCWnx 7 7 Global Edition Installation Manual Chapter 3 Installing Facility Commander Wnx Global configuration Figure 37 Create FCWnx database Select database server type Select Database Server Type fel ES FCWnx Database Select the database installation option from the list below Fe o This option will install a Global Database Server and ee es Orvar Distributor SQL Server must already be installed with an instance of SPSQL This option will install the Regional Database Server Regional Database Server on a local client A Distributor must be selected from ist below Select Global Database Server l cce 2 The Create Convert Database window opens as shown in Figure 38 Ignore the sa User Name as displayed The Password field displays your previously assigned and encrypted SQL password If you purchased your Facility Commander Wnx system from UTC Fire amp Security a temporary password of SecurityMaster08 case sensitive was assigned for you Accept the password as displayed FCWnx 7 7 Global Edition Inst
14. Wnx databases FCWnx 7 7 Global Edition Installation Manual 291 Chapter 12 Uninstall Facility Commander Wnx or delete a database If you are required to remove Microsoft SQL Server software due to file corruption beyond recovery you will need to perform the following 1 Stop SQL Server services 2 Stop any applications that are currently using SQL Server software 3 Back up your database files See Backup of Global Edition databases on page 282 To uninstall Microsoft SQL Server software 1 Click Start select Settings Control Panel and then Add Remove Programs 2 On the Add Remove Program Properties page select Microsoft SQL Server 2005 or 2008 3 Click Remove 4 You will receive a Microsoft SQL Server 2005 or 2008 Uninstall popup window asking you to select the components to remove Select the items to remove then click Next 5 A Confirmation window opens listing the items you selected to remove Click Finish to start the uninstall 6 You are returned to the Add Remove Programs window 7 Restart the server computer 292 FCWnx 7 7 Global Edition Installation Manual Chapter 13 Troubleshooting maintenance support Summary This chapter provides information to help you troubleshoot problems and contact technical support in case you need assistance with your UTC Fire amp Security equipment Content Troubleshooting 294 Installing FCWnx 294 Database creation errors 294 Installing and unins
15. _ lt Beck Net _ Cancel_ At the Database and FileServer Paths window the Database Server Name displays as read only It is unavailable for entry If the displayed Global Database Server Name is not appropriate select the appropriate Name from the drop down list Enter the computer name or click Browse to navigate to the File server computer for your system and then select the computer to display the name in this field Note You must install the File Server component on the selected file server in your Facility Commander Wnx system before attempting to license any Facility Commander Wnx application Click Next to display the Logon Account for SQL Server Services window as shown in Figure 95 Note Each Server used in the Facility Commander Wnx Global Edition system requires the database services to run under a domain user name and password account This account must have administrative privileges to that particular computer We suggest that you use the identical domain account at each computer used in the UTC Fire amp Security system FCWnx 7 7 Global Edition Installation Manual Chapter 4 Install Global Edition Regional configuration Enter the user domain and username in the format Domain Username or click Browse to navigate the Windows network and select Enter the domain user Password and click Next Figure 95 Logon Account for SQL Server Services Facility Commander Wnx 7 7 Setup lB x Logon Account
16. log off and then log back in as an administrator to the domain 2 Insert the FCWnx installation disc into the CD DVD drive When prompted click Run autorun exe If the disc does not launch you must manually start the software Using Windows Explorer navigate to the FCWnx Installation disc and then double click autorun exe 3 The Facility Commander Wnx Main Menu opens Click Install FCWnx v7 7 46 FCWnx 7 7 Global Edition Installation Manual Chapter 3 Installing Facility Commander Wnx Global configuration 4 The Facility Commander Wnx introduction page opens Click Install A series of windows may display as the listed components automatically install if not already there These components may cause the system to restart when a new version is installed If your computer restarts log on as Administrator and installation continues NET Framework Windows Installer Note On rare occasions when installing Facility Commander from a DVD drive the installation will stall for approximately 10 to 20 minutes from the time you click Install to the time when the Welcome to Facility Commander Wnx 7 7 Installation Wizard page opens If this occurs it is most likely caused by your anti virus software If you have anti virus software running you must configure it so that the DVD drive is not scanned Refer to the documentation that came with your anti virus software for details The Facility Commander Wnx installation processe
17. password O Change the password for the Windows Logon USERID Secure The FCWru installation creates a new Windows USERID called Secure By default the password is SecurityMaster08 If your Windows network has secunty policies that enforce rules for password creation you may want to change the Secure user password If you are unsure ask your System Administrator Use Default Password C Change Password New Password eeeeeececeeereeee Repeat New Password Wise Installation Weard 6 Click Next The Ready to Install the Application window opens 7 Enter the SQL Server password for the sa user This password was previously created during installation of SQL Refer to Installing Microsoft SQL Server on page 17 8 The default Destination Folder is indicated You may want to install to another location Click Browse to navigate to the program folder of your choice for placement of Facility Commander Wnx files 9 Click Next to continue Facility Commander Wnx copies system files updates the system configuration This may take a few minutes 10 When the Facility Commander Wnx has been successfully installed window opens click Finish 11 If your computer restarts log on and continue Creating the database custom installation To create the database 1 The Select Database Server Type window opens as shown in Figure 97 Select Regional Database Server and in the Selec
18. 1 Click Start and then click Control Panel 2 On the control panel double click Security Center and then click Windows Firewall 3 On the Exceptions tab make sure that the following check boxes are checked and then click OK e File and Printer Sharing e Network discovery e Workgroup Only Remote Administration Disable automatic windows update feature The automatic windows updates feature must be disabled To disable windows updates automatic feature 1 Click Start and then click Control Panel 2 On the control panel click Security Center and then click the Automatic Updates tab 3 On the Automatic Updates tab click Turn off Automatic Updates Click OK Items specific to Windows 7 Windows communication foundation HTTP activation If the Video Management Console VMC will be running on this computer Windows Communication Foundation HTTP Activation must be enabled FCWnx 7 7 Global Edition Installation Manual 247 Chapter 7 Windows 7 Vista and XP Professional system setup To enable Windows Communication Foundation HTTP Activation 1 Click Start Control Panel and then Programs 2 Under Programs and Features click Turn Windows features on or off 3 Search for Microsoft NET Framework 3 5 1 and then expand the folder Make sure the Windows Communication Foundation HTTP Activation check box is checked and then click OK Firewall exceptions list If the Firewall is selected ON the following must be e
19. 3 PIN 6 SHIELD GND PIN 2 GND PIN 7 PIN 1 PIN 8 8 PIN MODULAR TERMINAL BLOCK SPIN TERMINAL SECURE PERFECT PIN TERMINAL AMERICAN BLOCK SYSTEM DB25 BLOCK DYNAMICS DBSF RX 4 2 RX4 27X TXS 3 RX TXS 3 RX GND 7 GND GND 7 GND For the FCWnx system FCWnx computer Refer to Installation American Dynamics below Installation American Dynamics This interface program has a separate install utility in the FCWnx directory of the client computer or in the Client directory of the server computer The FCWnx American Dynamics program can be installed at the same time the FCWnx system is installed or any time thereafter Note Refer to your American Dynamics manual for DIP switch settings They should be set to the default settings To install FCWnx American Dynamics 1 You must be logged in to the FCWnx computer with administrator privileges If not log out and log back in Note The client on which you are installing FCWnx must be able to communicate on the network with the License Domain Controller 2 Click Start then Run 3 From the Run window click Browse Appendix C CCTV Interfaces 4 Inthe Look in field select the hard drive on which FCWnx is loaded such as C Then navigate to the directory in which FCWnx is installed The default is Program Files GE FCWnx Select the CCTVInstall exe Click Open In the Run window click OK o NON Provide the appropriate answers to prompts and click
20. 50 and Table 6 below Then proceed to the corresponding section of this chapter Note Some components require that a prerequisite component be installed at another computer before you begin Windows that display during installation are similar to the sample configurations presented Table 6 Custom configuration options Scenario Page 1 Database server file server and FCWnx client application configuration 52 2 Database server and file server configuration 57 3 Database server and FCWnx client application configuration 69 4 Database server configuration 79 5 Each component on a separate computer 92 Note When you select a scenario be sure to complete all instructions for that scenario FCWnx 7 7 Global Edition Installation Manual 51 Chapter 3 Installing Facility Commander Wnx Global configuration Database server file server and FCWnx client application configuration Components Computer 1 Computer 2 Computer 3 Database server v File server v FCWnx client application v Note This configuration has all components installed on Computer 1 Although these are the same components as Typical you chose Custom to use credential aliasing or change the secure password To install the database file server and FCWnx client application configuration 1 On the FCWnx Global Custom Configuration window select Database Server Global File Server and FCWnx Client Application
21. CCTV alarm you want to change The alarm information now displays 4 Make the required changes 5 Click Save To delete CCTV alarms within FCWnx 1 From the FCWnx Application Group pane select Gateways amp Interfaces then CCTV Interface 2 Click Search 330 FCWnx 7 7 Global Edition Installation Manual 3 In the Search Result window locate and then select the CCTV alarm you want to delete 4 Click Delete 5 You are prompted to verify your decision to delete Click Yes to delete or No to keep the record Pelco system The FCWnx Pelco interface supports the Pelco controller CM9760 The FCWnx Pelco interface provides the capability to automatically control Pelco CCTV cameras and to monitor remotely when FCWnx alarms change state To be able to monitor the alarms the desired FCWnx alarms must be linked or mapped to the appropriate CCTV cameras set up in Pelco When FCWnx received the mapped alarm FCWnx sends a message to the Pelco system to turn on the linked CCTV cameras and monitors The Pelco system then controls the appropriate cameras and monitors No operator intervention is required As an alarm is cleared by the operator from the Alarm Monitor form or when the FCWnx alarm resets the Pelco system is informed that the alarm is now reset and responded to and the appropriate camera turns off Setup overview To perform a successful configuration follow these steps 1 Setup the FCWnx system and th
22. Commander Wnx database consists of data files and transaction logs You have an option to place those components in different physical locations You may consider this if your IT Department has certain policies regarding database installation Consult with your IT Department for assistance Data File Directory The Data File Directory field displays the default directory Accept the default as displayed or click the Browse button and browse to any folder location where data files will be stored Note If you are installing in a Cluster configuration the Distributor installs to the same path as the Cluster Data File directory Log File Directory The Log File Directory field displays the default directory Accept the default or click the Browse button and browse to the folder location where database log files will be stored FCWnx 7 7 Global Edition Installation Manual 55 Chapter 3 Installing Facility Commander Wnx Global configuration Note This refers to the database logs this does NOT refer to the Facility Commander Wnx logs 5 Click Create Database The database creation begins and a progress bar is displayed This may take a few minutes Caution If a database already exists a warning message will display stating that you are about to overwrite your existing database with an empty default database Order of events Global database server database creation For information only this is the order of events taking place during
23. Database View Intearity Report cto __ oee 4 Click Create Database The database creation begins and a progress bar is displayed This may take a few minutes Caution If a database already exists a warning message will display stating that you are about to overwrite your existing database with an empty default database Order of events Regional database server database creation For information only this is the order of events taking place during the Regional database server database creation No action is required on the part of the user Table 15 Order of Events Regional database server database creation Step Description The Regional database server database is created SecurePerfect SecurePerfectHistory and SecurePerfectArchive The Regional database server contacts the SecurePerfectDistributor and Publisher on the Global database server The Regional database is added to the Subscriber s list at the Publisher and a new push subscription is created The Snapshot Agent is started at the Global Database server computer When the 4 agent completes the snapshot of the Global database the snapshot is applied to the Regional database server database 136 FCWnx 7 7 Global Edition Installation Manual Chapter 4 Install Global Edition Regional configuration Step Description The Merge Agent is started at the Global database server This agent on its initial creation applies
24. Database Initialize the Database Creation window opens as shown in Figure 81 Each Facility Commander Wnx database consists of data files and transaction logs You have an option to place those components in different physical locations You may consider this if your IT Department has certain policies regarding database installation Consult with your IT Department for assistance Data File Directory The Data File Directory field displays the default directory Accept the default as displayed or click the Browse button and browse to any folder location where data files will be stored Note If you are installing in a Cluster configuration the Distributor installs to the same path as the Cluster Data File directory FCWnx 7 7 Global Edition Installation Manual Chapter 4 Install Global Edition Regional configuration Log File Directory The Log File Directory field displays the default directory Accept the default or click the Browse button and browse to the folder location where database log files will be stored Note This refers to the database logs this does NOT refer to the Facility Commander Wnx logs Figure 81 Create Database Create Database FCWhnx 7 7 Database Initialize the database creation Fe m Database Directory Information C Program Files GE FC Winx Database C Program Files GE FCWrx Database View Integrity Report cet __ oe 4 Click Create Database The data
25. FCWnx key and need to change permission for the registry Caution Using the Registry Editor incorrectly can cause serious problems that may require you to re install your operating system Neither UTC Fire amp Security nor Microsoft guarantee that problems resulting from the incorrect use of Registry Editor can be solved Use Registry Editor at your own risk To change registry permissions 1 Click Start then Run In the Run window enter regedt32 Click OK Locate the HKEY_LOCAL_MACHINE key Double click the SOFTWARE icon to expand the folder tree Select GE and double click the GE icon to expand the folder tree 7 Select FCWnx Note If FCWnx is not there do not proceed Check with your Information Systems Department OF CO eB O N 296 FCWnx 7 7 Global Edition Installation Manual Chapter 13 Troubleshooting maintenance support Registry permission validation 1 2 3 From the main menu select Edit then Permissions In the Group or user names window locate and select SPAdmin Click Advanced Select the Allow inheritable permissions from the parent to this object and all child objects Include these with entries explicitly defined here check box 5 Click Apply then click Ok 6 In the Permissions portion of the Security window select Allow for Full Control Click Apply then click OK From the main menu select Registry then Exit FCWnx 7 7 Global Edition Installation Manual 297 Chapter 13 T
26. Figure 23 FCWnx Global Custom configuration All components selected re Facility Commander Wnx 7 7 Setup FCVvnx Global Custom Configuration aS Choose the appropriate components for a custom Global Edition installation a IV Database Server Choosing this option will install the FCWnx database components Please select which type of server Global Only one of these per FCWnx Global Edition installation C Regional There can be several of these for an FCWnx Global Edition intel IV File Server Choosing this option will install the FCwnx File Server components IV FCWnx Client Application Choosing this option vall install the FCWnx Client Application Wise Installation Wizard coat 2 Click Next The Logon Account for SQL Server Services window opens as shown in Figure 24 52 FCWnx 7 7 Global Edition Installation Manual Chapter 3 Installing Facility Commander Wnx Global configuration Note Each server used in the Facility Commander Wnx Global Edition system requires the database services to run under a domain user name and password account This account must have administrative privileges to that particular computer We suggest that you use the identical domain account at each computer used in the system Figure 24 Logon account for SQL Server services 7 Bb m i Facility Commander Wnx 7 7 Setup a ol xi Logon Account for SQL Server Services Enter the domain user account to be used by Microso
27. Fire amp Security at 561 998 6168 to discuss Windows Clustering setup and installation before installing Facility Commander Wnx UTC Fire amp Security business sales representative or Customer Support at 1 888 437 3287 can provide additional details of these services and a quotation applicable to your system configuration What s next Proceed to Chapter 3 Installing Facility Commander Wnx Global configuration on page 39 38 FCWnx 7 7 Global Edition Installation Manual Chapter 3 Installing Facility Commander Wnx Global configuration Summary This chapter is for experienced software installers and includes instructions for Facility Commander Wnx Global configuration software for a Global database server Global configuration software introduces technology for copying and distributing data and database objects from one database to another and then synchronizing between databases for consistency We recommend that you review the entire chapter and discuss with your IT Department before you begin your configuration Content Benefits of Facility Commander Wnx Global configuration 41 Sample configuration overview 41 Global configuration definitions 43 Preinstallation checklist 44 Adding the computer toa domain 45 Adding SQL Server and SQLServerAgent services to a domain 45 Installation 46 Before you begin 46 Starting the installation 46 Facility Commander Wnx software installation begins 47 CUSTOM Installation Facilit
28. Global configuration in order for the new client to be recognized all currently installed Global configuration server computers and client computers must be restarted Logging on to client computer Note Restart the client computer at this time if you have not already done so During installation of the Facility Commander Wnx software a default local Windows user is created You will need to log on to the client computer as a user that is part of the SPAdmin local group By default a user secure with the password SecurityMaster08 case sensitive was created for you and added to the SPAdmin group If the services are started you are now ready to open the Facility Commander Wnx application Refer to Setting services to automatic startup on page 258 to verify if Facility Commander Wnx Services are started To access Facility Commander Wnx after installation 1 To access Facility Commander Wnx from your desktop icon double click the Facility Commander Wnx icon pictured below 260 FCWnx 7 7 Global Edition Installation Manual Chapter 8 Installing Facility Commander Wnx Software on additional clients p Facility Commander Wnx 2 As an alternative access Facility Commander Wnx from the Start menu Click Start Programs and then Facility Commander Wnx The Facility Commander Wnx menu displays The options are as follows e Diagnostic Viewer Refer to the Diagnostic Viewer online help for details of this option e
29. If it is not already installed on your system you will need to install it now along with the latest applicable Service Packs WARNING The computer must not be configured for Sleep Mode or Hibernate Mode All Facility Commander Wnx services such as monitoring and transferring events or alarms will not function if the computer is in Sleep Mode or Hibernate Mode Make sure that your computer setting for Sleep Mode and Hibernate Mode is set to NEVER It is also a good practice to set your Turn off display setting to Never Refer to the documentation that came with your version of Windows for details on these settings or check with your IT department Note For the Credential Designer features to function properly the Windows operating system must be installed on drive C Insert the Windows 2003 or Windows 2008 Installation disc in your CD DVD drive and follow the instructions provided by the Microsoft documentation Note If you purchased this system from UTC Fire amp Security the operating system is installed for you Windows user password For Facility Commander Wnx to work correctly once installed all Windows login IDs used in conjunction with Facility Commander Wnx should have an assigned password Do not leave blank Matching user information All computers within an FCWnx system must use a matching user name and password at login in order to communicate Assigning user passwords We recommend that you assign a password
30. Imaging an image capture device such as a USB or Refer to image capture USB2 0 camera device manufacturers literature E Prepare operating system Windows XP Professional on page 241 Install Facility Commander Wnx software e Custom on page 255 G License the client computer on page 258 1 Repeat these steps for each client computer FCWnx 7 7 Global Edition Installation Manual Chapter 2 Windows Server 2003 2008 Standard and Enterprise Edition Server setup Summary This chapter provides instructions for a sample configuration of a Windows 2003 and Windows 2008 Standard and Enterprise Edition server computer We recommend that you review the Preinstallation checklist on page 10 and then review the sample configuration carefully before you begin the installation Note If you are installing to a Cluster environment refer to your Microsoft documentation and the Documentation disc shipped with your Facility Commander Wnx system nstalling Facility Commander Wnx in a Clustered Environment in PDF format Content Preinstallation checklist 9 Network card 10 Configuring the computer for the network 10 Determining server type 10 Installing the operating system 11 Windows user password 11 Matching user information 11 Assigning user passwords 11 Windows 2003 Server 12 Windows 2008 Server 12 Setting up your monitor 12 Setting the network properties 13 Windows Server 2003 13 FCWnx 7 7 Global Edition Installation Manual
31. NT ALTHORITYILOCALS Manual SQL Server Browser NT AUTHORITY LOCAL S Automatic H 20 The Database Engine Configuration window opens Click the Account Provisioning tab and then configure the settings as follows See Figure 16 on page 34 Authentication Mode Click Mixed Mode SQL Server authentication and Windows authentication Built in SQL Server system administrator account In the Enter password field enter the sa password The default sa password is SecurityMaster08 case sensitive Specify SQL Server administrators Click Add The Select Users or Groups window opens as shown in Figure 17 on page 34 In the Enter the object names to select field enter Administrator and then click Check Names to make sure you have entered the Administrator for this computer Click OK to close the Select Users or Groups window Click Next FCWnx 7 7 Global Edition Installation Manual 33 Chapter 2 Windows Server 2003 2008 Standard and Enterprise Edition Server setup Figure 16 Database Engine configuration hE soL server zoog setup dix Database Engine Configuration Specify Database Engine authentication security mode administrators and data directories Setup Support Rules Account Provisioning Data Directories FILESTREAM Feature Selection eE E Specify the authentication mode and administrators for the Database Engine Disk Space Requirements Authentication Mode S
32. New Window from Here Cut Delete Refresh Properties Help Add a folder target to the selected folder 7 The New Folder Target page opens Under the Path to folder target click Browse to display the Select Computer page On the Select Computer page click Advanced to display the Select Computer pages shown in Figure 140 Click Find Now 218 FCWnx 7 7 Global Edition Installation Manual Chapter 5 Configuring Global Edition for file replication Figure 140 Select Computer Select this object type Computer Object Types From this location aisneyworid com Locations Common Queries Name Stats with o O O Columns Description Stats with x Tl Disabled accounts Stop J Non expiting password Days since last logon x a Search results a ma 8 From the search results select your Regional Server and then click OK You are returned to the Select Computer page with the Regional Server name entered in the Enter the object name to select field Click OK 9 The Browse for Shared Folders page opens as shown in Figure 141 Click on the shared folder that you want to link to the shared folder created on the Global Server such as Firmware and then click OK Figure 141 Browse for Shared Folders Browse for Shared Folders __ 5 x Server JREGIONAL22BIT Browse Show Shared Folders Shared folders Designs Extemals Licenselnf
33. Next to continue During installation you are prompted with a few questions e Type of CCTV Interface Select American Dynamics e Description or name for the interface Enter a description for this interface such as Main Building CCTV Note If multiple same type CCTV interfaces are installed on a single FCWnx network the description of each interface must be unique e COM port to which this interface is connected Select the COM port 9 Click Install to complete the installation 10 Once the installation is complete from the Control Panel select System Hardware tab Device Manager Ports Select the COM port you previously selected in the installation and provide identical settings for baud rate data bits parity stop bits and flow control as your CCTV Controller s setup _ When you are ready to launch the CCTV program you need to restart the FCWnx services on this client 12 Once the system is running log on to the computer as an FOWnx user and start the FCWnx application Log on to FCWnx and from the Application Group pane Monitors amp Controls group select Client Monitor You notice an entry for the CCTV you just installed 13 To start the CCTV application you need to create CCTV alarms in the CCTV Alarm form first Then you need to map the desired FCWnx alarm to CCTV on the Alarm form CCTV tab Configuring alarms below and Monitoring on page 337 14 To start your CCTV interface click
34. Resets If you selected when the alarm is cleared from the Alarm Monitor then you need to clear the FCWnx alarm from the Alarm Monitor before the RESET message is sent to the controller Appendix C CCTV Interfaces However if you selected when the alarm Resets you can observe the results on the Allegiant system as FCWnx alarms are SET and RESET indicated by the red and green LED on the FCWnx Alarm Monitor All FCWnx alarms that trigger CCTV alarms must be monitored Diagnostics A diagnostic object called CCTV reports all diagnostics for all CCTV interfaces on the client For details of the diagnostic utility refer to your FOWnx Online Help Removal of CCTV client interface The FCWnx CCTV interface program is removed when you delete the client interface from any one of the FCWnx client computers Note You must first remove all CCTV alarm mapping before you can delete the CCTV interface To remove the CCTV client interface 1 From the Application Group pane Administration group select Client to open the Client form 2 Click Search to display all records 3 Select the CCTV client 4 Click Delete on the FCWnx toolbar 338 FCWnx 7 7 Global Edition Installation Manual
35. Sh Services Local lt Se FCWnx Diagnostics 5 Description Status Startup Type Log On As S Encrypting File System EFS Provides the core file encrypti Manual Local System Stop the service GA Extensible Authentication Protocol The Extensible Authentication Manual Local System Restart the service 3 s Fax Enables you to send and recei Manual Network Service Sh FCWnx API Service Provides COM API for use by Manual Local System Description p Provides logging support for FCWnx services and applications vi FCWnx Manager Manages FCWnx physical and Manual Local System Sh FCWnx Media Server Provides video device services Manual Local System Gh FCWnx System Manager Manages FCWnx low level int Manual Local System Sh FCWnx WebService Provides web service API for u Manual Local System vy FCWnxWCF Service Provides WCF API for use by F Manual Local System 4 m Extended A Standard n 2 Select FCWnx Diagnostics The status will be either Started or blank If it is blank then the service is not running 4 Right click and then select Properties In the Startup type field select Automatic 5 Click Apply and then OK to close the window FCWnx 7 7 Global Edition Installation Manual 109 Chapter 3 Installing Facility Commander Wnx Global configuration 6 Repeat steps 3 through 6 for the following services e FCWnx Manager e FCWnx Media Server FCWnx System Manager FCWnx Web
36. System Tools a Event Viewer Z system Information gil Performance Logs and Alerts Replicator 3 Shared Folders Busers Members A 5 OA A Jee Goa BsPacnin SECUREPERFECT Administrator E Users fP SECUREPERFECT Secure Perfect Users Groups Sa Storage E Disk Management B Disk Defragmenter amp Logical Drives 4 2 Removable Storage T Services and Applications H A 0 Cancel To add a new Global group to each computer in the domain that is going to run Facility Commander 1 a aA N Click Start Programs Administrative Tools and then Computer Management Expand Local User and Groups then Groups Select and then right click SPAdmin from the list of Groups displayed Select Properties from the shortcut menu Click Add and Look in Active Directory Locate and add Facility Commander Wnx Users Click Add and then click OK Your windowpane should display similar to Figure 115 On the domain you created a new Global group entitled Facility Commander Wnx Users You then added Administrators as members of that group Since the group is Global any users added to the Facility Commander Wnx Users group at the Active Directory will have permission to start the Facility Commander Wnx program FCWnx 7 7 Global Edition Installation Manual 193 Chapter 4 Install Global Edition Regional configuration Note Now any members added to the Facility Commander Wnx Users group at
37. Target 209 File Replication on Windows 2008 with SQL 2008 213 Verifying Distributed File System service is started 213 Configuring the DFS namespace 214 Configuring DFS file replication 214 Adding additional clients to the database 220 Pinging additional client computers 220 Adding clients to the database 222 What s next 223 FCWnx 7 7 Global Edition Installation Manual 199 Chapter 5 Configuring Global Edition for file replication Configuring file replication services Note At this point you should have configured the Facility Commander Wnx Global database server all Regional database servers and all client computers to specific Servers The next step is configuring for file replication at the Global Database server computer There is a global database at the Global Server and a database at each of the Regional Servers SQL Server Replication services are used to distribute the data from the Global Server to each of the Regional Servers File Replication for FCWnx shared directories is accomplished using Microsoft Active Directory in combination with Microsoft Directory File Services This section includes instructions to configure your system for file replication at the Global database server For Windows 2008 Server SQL Server 2008 systems you must install the Distributed File System prior to configuring file replication Refer to Windows Server 2008 Distributed File System on page 36 Before attempting to set up F
38. The UPS shall comply with the Standard for Uninterruptable Power Supply Equipment UL 1778 or the Standard for Fire Protective Signaling Devices UL 1481 7 A UL Listed printer shall be provided 8 Signal prioritization shall be set up as follows from highest to lowest Alarm Trouble Supplementary such as access control 9 Polling of a receiving unit must not exceed 200 seconds 10 Exit and Entry delay must not exceed 60 seconds 300 FCWnx 7 7 Global Edition Installation Manual Appendix A UL certification requirements 11 Communication between Host and Protected Premise Units must consist of an independent dedicated and direct Ethernet line Communication over LAN and WAN has not been investigated by UL 12 Elevator Control DVR CCTV Camera functions and Keypad Alarm Response have not been evaluated by UL 13 Any communication failure shall be treated as a compromise of the Encrypted Line Security of the proprietary burglar alarm system when installed with NIST validated Triple DES C module Version 1 1 14 The minimum system configuration for the Facility Commander Wnx monitoring equipment consists of a Listed Pentium computer with a minimum CPU speed of 2 GHz 2 GB RAM 10 GB HDD and 10 100 NIC A color monitor shall also be provided 1024 x 768 resolution 16 bit color display FCWnx 7 7 Global Edition Installation Manual 301 Appendix B Optional hardware and software Summary This appendix details
39. Wnx until this is accomplished Starting the installation Note If you purchased this system from UTC Fire amp Security Facility Commander Wnx is installed for you Skip to Chapter 9 Logging on and configuring Facility Commander Wnx on page 265 To install the Facility Commander Wnx application 1 You mustbe logged in as administrator user to the domain If not log off and log back on as a user with administrator permissions 2 Insert the Facility Commander Wnx installation disc into the CD DVD drive If the disc does not launch you must manually start the software Using Windows Explorer navigate to the FCWnx Installation disc and double click Setup exe 3 The Facility Commander Wnx introduction page opens Click Install A series of windows may display as the listed components automatically install if not already there These components may cause the system to restart when a new version is installed If your computer restarts log on as Administrator and installation continues NET Framework Windows Installer Note On rare occasions when installing Facility Commander from a DVD drive the installation will stall for approximately 10 to 20 minutes from the time you click Install to the time when the Welcome to Facility Commander Wrx 7 7 Installation Wizard page opens If this occurs it is most likely caused FCWnx 7 7 Global Edition Installation Manual 253 Chapter 8 Installing Facility Commander Wnx Sof
40. add features to an existing SQL Server 2008 instance Maintenance a i New SQL Server failover duster installation ools Launch a wizard to install a single node SQL Server 2008 failover cluster Resources Add node to a SQL Server failover duster Advanced x yi Q val Launch a wizard to add a node to an existing SQL Server 2008 failover cluster Options Upgrade from SQL Server 2000 or SQL Server 2005 Launch a wizard to upgrade SQL Server 2000 or SQL Server 2005 to SQL Server 2008 Before you upgrade you should run the Upgrade Advisor to detect potential problems T Search for product updates Search Microsoft Update for SQL Server 2008 product updates 11 The Setup Support Rules window opens When the operation is complete click OK 12 The Product Key window opens If the product key is not already entered for you enter the product key and then click Next 13 The License Terms window opens Review the agreement and then select accept the license terms Click Next 14 The Setup Support Files window opens and provides a list of components that are required for SQL Server setup Click Install 15 The Setup Support Rules window opens and identifies problems that might occur when you install SQL Server Setup support files Click Next 30 FCWnx 7 7 Global Edition Installation Manual Chapter 2 Windows Server 2003 2008 Standard and Enterprise Edition Server setup 16 The Feature Selection window opens as shown
41. agent on its initial creation applies the database snapshot taken by the Snapshot Agent to the Regional 5 database A schedule is updated to operate every day every one minute and set to run As records are added deleted or updated on Regional Servers or the Global database server the changes are replicated to all database Subscribers A new history transactional publication is created on the Regional database server The name of the publication will be similar to the following SecurePerfectHistory SPHistoryPublication A subscription to this publication is created 6 on the Global database server The name of this subscription is Global servername SPSQL SecurePerfectHistory Each Region s history is replicated to the Global database server but it does not redistribute Regional data to another Region History data is a one way replication A new push subscription is created on the Region a snapshot is started and the Transactional Agent is run Note For each history publication on the Regional server there is a corresponding subscription on the Global server while the SecurePerfect database publication has multiple subscribers 5 Remove the Facility Commander Wnx installation disc and continue with instructions to install FCWnx Client Application 6 A message opens FCWnx Database successfully created Note A log file is created when the Create Database program is run The log file called CreateDatabaseLog
42. alarms are the actual messages that are sent to the Allegiant interface They control the sequence of monitors and cameras are switched on and off The Allegiant controller is preprogrammed to interpret these messages To program the Burle Allegiant controller refer to the manual on the Burle Allegiant command console language To 1 add CCTV alarms within FCWnx From the FCWnx Application Group pane select Gateways amp Interfaces then CCTV Interface 2 Click Add 3 In the Description field enter the appropriate description for your system Example Burle Allegiant CCTV Alarm 4 In the CCTV Interface field choose Burle Allegiant 5 Inthe CCTV Alarm field choose the alarm number of the interface you are 8 monitoring The Enable Message and Disable Message fields are automatically filled Use these default settings In the Reset CCTV Alarm field two reset choices for the alarm are provided When the alarm is cleared from the Alarm Monitor or When the alarm Resets This means the reset or the disable message can be sent when the FCWnx alarm e Is cleared from the Alarm Monitor e Resets Click Save To change CCTV alarms within FCWnx 1 From the FCWnx Application Group pane select Gateways amp Interfaces then CCTV Interface Click Search 3 In the Search Result window locate the CCTV alarm you want to change then select it The alarm information now displays 4 Make the desired
43. and 120 FCWnx 7 7 Global Edition Installation Manual 227 Chapter 6 License and Set Security Settings for your FCWnx System License controller 4 The Machine Seed Key is displayed for information only and is a read only field 5 In the License Key sections enter the 35 character license key string obtained through the UTC Fire amp Security Web site You can type the entry into the control dialog boxes or select copy and paste by clicking any License Key edit control boxes to paste the entire key File server 6 The Path for license information file located on the File Server is a read only dialog box and displays for information only 7 The Browse button is enabled and allows selection of file server license information path to give the user an opportunity to log in to the remote computer if the currently logged in user does not have permissions for the folder When you navigate to and find the server computer you must select the Licenselnfo folder to display the Server name folder name combination in this dialog box 8 Click Register An SQL Server Login window opens 9 Enter the password for the SQL Server sa user and click OK 10 A message displays informing you that the license setup was successful and that the services will be stopped 11 Click OK The license program exits The system registers the license key for this client and the software is licensed for use Note The computer in your system tha
44. at Regional database server If a displayed Database Server Name is not correct enter or select the appropriate name from the drop down list If a displayed File Server Name is not correct navigate to the file server computer for this client and select to display in the File Server Name dialog box 148 FCWnx 7 7 Global Edition Installation Manual Chapter 4 Install Global Edition Regional configuration Figure 84 Database and FileServer Paths at Regional database server 8 10 te Facility Commander Wnx 7 7 Setup oe zox E a Global Database and FileServer Paths O Global Database Server Name 9 Database Server Name nTa z File Server Name BDD Wise Installation Wizard oo We ces Click Next The Change the Secure password window opens The Facility Commander Wnx installation creates a new Windows User ID called secure By default the password is SecurityMaster08 case sensitive If your Windows network has security policies that enforce rules for password creation you may need to change the secure user password If you are unsure ask your system administrator Select one of the following on the Change the Secure password window e Use Default Password e Change Password If you select this option enter your new password and then enter a second time Click Next The Ready to Install the Application window opens The default Destination Folder is indicated You may want to install to
45. available for entry 10 Click OK The new Server name displays in your Microsoft SQL Server Management Studio navigation tree similar to Figure 160 Figure 160 SQL Server Enterprise Manager navigation tree R Microsoft SQL Server Management Studio oj xj File Edit View Tools Window Community Help Doew Query D D G or al aw DIREI 5 A Security E Server Objects A Replication O Management O Notification Services SQL Server Agent Summary BER E List report z J TEST SPSQL SQL Server 9 0 2047 sa TEST SPSQL 7 Item s C Databases Security E Server Objects E Replication Management Notification Services Asan Server Agent 11 Close the Microsoft SQL Server Management Studio 276 FCWnx 7 7 Global Edition Installation Manual Chapter 10 Logging off and shutting down Summary This chapter details the process of exiting logging off or shutting down Facility Commander Wnx and your computer Content Exiting Facility Commander Wnx 278 Quitting Facility Commander Wnx application 278 Shutting down 278 Logging off of Windows 279 Automatic client shutdown 279 FCWnx 7 7 Global Edition Installation Manual Chapter 10 Logging off and shutting down Exiting Facility Commander Wnx When exiting Facility Commander Wnx you have two options e Exit e Log off Exit Exit logs off the operat
46. com technet For Windows 7 and Windows 2008 operating systems if you are using multiple network interface cards NICs for FCWnx related use make sure that you choose the same network profile for each NIC When attaching your NIC toa new not previously configured network a popup window opens asking whether this new network is Home Work or Public Make sure you choose the same for both NICs so that when FCWnx is installed and SecurityCnfg is run the profile will have the correct FCWnx ports open Configuring the computer for the network Determining server type Before you continue you will need to decide what type of server the server computer will be in the network Always consult with the network administrator before adding any computers to an existing network The server computer must be part of a domain See Adding the computer to a domain on page 15 It is important that the server and Client system use the same network properties Refer to Setting the network properties on page 13 for more information or consult with your network administrator Setup will be different depending on which option you choose Decide which server type applies before you continue with the installation 10 FCWnx 7 7 Global Edition Installation Manual Chapter 2 Windows Server 2003 2008 Standard and Enterprise Edition Server setup Installing the operating system The server computer must be running Windows 2003 or Windows 2008 Server
47. computer part of an FC Wnx Global Edition installation Yes C No Wise Installation Wizard 3 The Custom Configuration window opens for you to choose which Facility Commander Wnx features to configure on this computer The Custom Configuration window opens as shown in Figure 68 FCWnx 7 7 Global Edition Installation Manual 127 Chapter 4 Install Global Edition Regional configuration Figure 68 FCWnx Regional Custom Configuration 128 i Facility Commander Wnx 7 7 Setup SSS ioj x FCWnx Global Custom Configuration oS Choose the appropriate components for a custom Global Edition installation lt G IV Database Serves i _ ___ _ Choosing this option will install the FCWnx database components Please select which type of server Global Only one of these per FCWnx Global Edition installation Regional There can be several of these for an FOWnx Global Edition installation IV File Server Choosing this option will install the FCwnx File Server components IV FCWnx Client Application Choosing this option vall install the FCWnx Client Application Wise Installation Wizard Select one or more of the options pertaining to the system you are installing Note Some components require that a prerequisite component be installed at another computer before you begin Database server This option is used to store the three databases SecurePerfect SecurePerfectArchive and Sec
48. database server on the first computer 1 On the FCWnx Global Custom Configuration window select Database Server and Global as shown in Figure 41 FCWnx 7 7 Global Edition Installation Manual 79 Chapter 3 Installing Facility Commander Wnx Global configuration Figure 41 FCWnx Global Custom configuration Database server iy Facility Commander Wnx 7 7 Setup FCvinx Global Custom Configuration Choose the appropriate components for a custom Global Edition installation 2 Click Next A Database and FileServer Paths window opens similar to Figure 42 on page 81 80 FCWnx 7 7 Global Edition Installation Manual Chapter 3 Installing Facility Commander Wnx Global configuration Figure 42 File server name required i Facility Commander Wnx 7 7 Setup a 10 x Global Database and FileServer Paths O S File Server Name E Browse Wise Installation Wizard cmn 3 At the Database and File Server Paths window the Global Database Server Name and Database Server Name display as read only They are unavailable for entry 4 Enter the computer name or click Browse to navigate to the File server computer for your system and then select the computer to display the name in this field Note You must install the File Server component on the selected file server in your Facility Commander Wnx system before attempting to license any Facility Commander Wnx application 5 The Logon Account for SQL Se
49. folders will display gmcNls A folder that contains the language support files for the GMC application After the base install of FCWnx these folders are empty as no language kits have been installed yet As the language kits are installed the language support files are placed in this folder GraphicsCache A folder that contains the working data files for the Graphics Monitoring and Control GMC application jre A folder that contains the Java Runtime Environment used by GMC and VMC Logs A shared folder that contains the Facility Commander Wnx diagnostic log files Rpt A folder that contains files used by the report engine to create Facility Commander Wnx reports UserManuals A folder that contains the FCWnx and GMC User Manuals in pdf format VideoSubsystem A folder that contains the dlls that enable communication between FCWnx and VMC Vmc A folder that contains the Java code for the Video Monitoring and Control VMC application vmcNis A folder that contains the language support files for the VMC application After the base install of FCWnx these folders are empty as no language kits have been installed yet As the language kits are installed the language support files are placed in this folder What s next You have completed the client computer setup Now proceed to configure the client parameters 264 FCWnx 7 7 Global Edition Installation Manual Chapter 9 Logging on and configuring Facility Commander Wnx
50. for SOL Server Services Enter the domain user account to be used by Microsoft SOL Server for replication gt Global Edition uses Microsoft SQL Server Replication technology Pepica requires that SOL Server Services are running using a domain user account that has administrator privileges on both the local machine and also on the other FOWnx database servers that are part of the Global Edition installation The domain and user name should be entered with the following format Domain UserN ame For example SPDomain Secure Domain U ser Name Password Wise Installation Wizard 5 The Change the Secure password window opens as shown in Figure 96 on page 164 The Facility Commander Wnx installation creates a new Windows User ID called secure By default the password is SecurityMaster08 case sensitive If your Windows network has security policies that enforce rules for password creation you may need to change the secure user password If you are unsure ask your system administrator Select one of the following on the Change the Secure password window e Use Default Password e Change Password If you select this option enter your new password and then enter a second time FCWnx 7 7 Global Edition Installation Manual 163 Chapter 4 Install Global Edition Regional configuration Figure 96 Change the Secure password window is Facility Commander Wnx 7 7 Setup Change the Secure
51. for login instructions Note The computer in your Facility Commander Wnx system that accesses and completes the registration for the first time is the license controller computer The license key is stored on the license controller computer therefore the license controller computer must be online with Facility Commander Wnx services running in order to license additional client computers 13 We recommend that you store your license agreement number in a safe place so that if the license key is ever destroyed or corrupted you can reinstall without having to contact UTC Fire amp Security About Facility Commander Wnx license summary Following a successful login the Edition of Facility Commander Wnx installed on your computer as well as the Service Pack if any and parameters of your system display in the Facility Commander Wnx application Help menu About FCWnx window similar to the following 232 FCWnx 7 7 Global Edition Installation Manual Chapter 9 License and Set Security Settings for your FCWnx System Figure 145 Help Menu About window About FCWnx FCWnx 7 7 Global Edition Installation Manual 233 Chapter 9 License and Set Security Settings for your FCWnx System SecurityCnfg Utility This application assists you in configuring firewall and DCOM settings on your computer We recommend that you configure your FCWnx system with the Windows firewall ON In order for your system to perform success
52. halted e NET Framework A popup message opens informing you that installation will be cancelled until you install the required software in the appropriate language to the operating system you are installing You cannot install Facility Commander Wnx until this is accomplished The following components cause the system to restart when a new version is installed e NET Framework Windows Installer If your computer restarts log on as administrator and installation continues The Facility Commander Wnx installation processes updates on your system When the latest versions of each component are updated and identified FCWnx 7 7 Global Edition Installation Manual 65 Chapter 3 Installing Facility Commander Wnx Global configuration Facility Commander Wnx installation begins and the Welcome window opens Continue with Facility Commander Wnx software installation begins below Facility Commander Wnx software installation begins Note A Cancel button displays on every FCWnx installation window If you click Cancel at any time during the installation the FCWnx installation process stops but all Windows components that have been installed must be manually removed To install the Facility Commander Wnx application 1 The Facility Commander Wnx Welcome window opens Click Next The License Agreement window opens Select accept the license agreement and then click Next The Select Installation Type window opens as sho
53. in your Facility Commander Wnx system before attempting to license any Facility Commander Wnx application FCWnx 7 7 Global Edition Installation Manual 93 Chapter 3 Installing Facility Commander Wnx Global configuration Figure 51 File server name required 3 94 The Logon Account for SQL Server Services window opens as shown in Figure 52 Note Each server used in the Facility Commander Wnx Global Edition system requires the database services to run under a domain user name and password account This account must have administrative privileges to that particular computer We suggest that you use the identical domain account at each computer used in the UTC Fire amp Security system FCWnx 7 7 Global Edition Installation Manual Chapter 3 Installing Facility Commander Wnx Global configuration Figure 52 Logon account for SQL server services te Facility Commander Wnx 7 7 Setup Logon Account for SOL Server Services Enter the domain user account to be used by Microsoft SQL Server for replication Global Edition uses Microsoft SQL Server Replication technology Replication requires that SQL Server Services are running using a domain uset account that has administrator privileges on both the local machine and also on the other FOWnx database servers that are part of the Global Edition installation The domain and user name should be entered with the following format Domain Use N ame For example SPD
54. installed If your computer restarts log on as Administrator and installation continues e NET Framework e Windows Installer Note On rare occasions when installing Facility Commander from a DVD drive the installation will stall for approximately 10 to 20 minutes from the time you click Install to the time when the Welcome to Facility Commander Wnx 7 7 Installation Wizard page opens If this occurs it is most likely caused by your anti virus software If you have anti virus software running you must configure it so that the DVD drive is not scanned Refer to the documentation that came with your anti virus software for details 5 The Facility Commander Wnx installation processes updates on your system When the latest versions of each component are updated and identified Facility Commander Wnx installation begins and the Welcome window opens Continue with Facility Commander Wnx software installation begins on page 77 Facility Commander Wnx software installation begins Note A Cancel button displays on every FCWnx installation window If you click Cancel at any time during the installation the FCWnx installation process stops but all Windows components that have been installed must be manually removed 180 FCWnx 7 7 Global Edition Installation Manual Chapter 4 Install Global Edition Regional configuration To install the file server on the second computer 1 The Facility Commander Wnx Welcome window opens Click Nex
55. is not yet installed To set the startup method of Facility Commander Wnx Services 1 Click Start Control Panel Administrative Tools and then Services The Services window displays Expand the list of services and scroll down 258 FCWnx 7 7 Global Edition Installation Manual Chapter 8 Installing Facility Commander Wnx Software on additional clients Figure 151 FCWnx component services File Action View Help leo i as hm gt au FCWnx Diagnostics Name Description Status Startup Type Log On As z Gh Encrypting File System EFS Provides the core file encrypti Manual Local System G Extensible Authentication Protocol The Extensible Authentication Manual Local System S Fax Enables you to send and recei Manual Network Service s FCWnx API Service Provides COM API for use by Local System Stop the service Restart the service Description Provides logging support for FCWnx services and applications agnost rovides logging support fo cal System 1 FCWnx Diagne p tfor Local Systerr Sh FCWnx Manager Manages FCWnx physical and Local System GA FCWnx Media Server Provides video device services Local System Gh FCWnx System Manager Manages FCWnx low level int Local System Sh FCWnx WebService Provides web service API for u Local System Sh FCWnxWCF Service Provides WCF API for use by F Local System 4 w Extended Standard 2 Select FCWnx Diagnostics Th
56. manually removed To install the File Server and FCWnx Client Application on the second computer 1 2 88 The Facility Commander Wnx Welcome window opens Click Next When the License Agreement window opens select accept the license agreement and click Next The Select Installation Type window opens as shown in Figure 47 Select the type of installation as Custom and then click Next FCWnx 7 7 Global Edition Installation Manual Chapter 3 Installing Facility Commander Wnx Global configuration Figure 47 Selection Installation type Custom Select installation Type Select the desired installation type Typical i mo The most common application features will be installed This option F z pai azi is recommended for most users Custom installed and where they will be installed Recommended for a Use this option to choose which application features you want a advanced users Wise Installation Wizard 4 The Install FOWnx Client Server window opens This window opens only if this is a domain computer You must be part of a domain to continue 5 Select Yes when asked Is this computer part of an FCWnx Global Edition Installation and click Next The Custom Configuration window opens 6 On the FCWnx Global Custom Configuration window select File Server and FCWnx Client Application FCWnx 7 7 Global Edition Installation Manual 89 Chapter 3 Installing Facility Commander Wnx G
57. may want to change the Secure user password If you are unsure ask your System Administrator Use Default Password Change Password New Password Repeat New Password eeeeeosececeoeces Wise Installation Wearde lt Back Next gt Cancel 6 Click Next The Ready to Install the Application window opens 7 Enter the SQL Server password for the sa user This password was previously created during installation of SQL Refer to Installing Microsoft SQL Server on page 17 Note Enter your previously assigned SQL password here If you purchased your Facility Commander Wnx system from UTC Fire amp Security a temporary password of SecurityMaster08 case sensitive was assigned for you 8 The default Destination Folder is indicated You may want to install to another location Click Browse to navigate to the program folder of your choice for placement of Facility Commander Wnx files 9 Click Next to continue Facility Commander Wnx copies system files updates the system configuration and displays the Facility Commander Wnx icon on your desktop This may take a few minutes 10 When the Facility Commander Wnx has been successfully installed window opens click Finish 11 If your computer restarts log on and continue Creating the database custom installation To create the database 1 The Select Database Server Type window opens as shown in Figure 73 FCWnx 7 7 Global Edition Insta
58. only need to be backed up if you have Imaging installed Contains the credential design files The Designs folder is located in the Facility Commander Wnx folder e Externals A shared empty folder created to store reports created by third party report generators e Firmware A shared folder that contains controller firmware e Video A shared folder that contains captured video files Entire Facility Commander Wnx installation The entire Facility Commander Wnx folder should be backed up when you first set up the system and have confirmed that it is working and any time you upgrade It is very important that you also back up the registry settings In most backup programs you will be prompted to back up these settings Note ALWAYS MAINTAIN A CURRENT BACKUP Should you have any problems with your system you can always restore your backup This includes your database as well as your files Backing up the databases using SQL Server There are four databases which should be backed up on a continual basis since the information may change frequently e SecurePerfect e SecurePerfectArchive e SecurePerfectHistory For a description of these databases refer to Backing up overview on page 282 Before you back up your database 1 Verify that you have the correct permission level to access the database We recommend logging on as Administrator sa or whatever the current Administrator login assigned at installation F
59. option enter your new password and then enter a second time 6 Click Next The Ready to Install the Application window opens 7 The default Destination Folder is indicated You may want to install to another location Click Browse to navigate to the program folder of your choice for placement of Facility Commander Wnx files 8 Click Next to continue Facility Commander Wnx copies system files and updates the system configuration This may take a few minutes 78 FCWnx 7 7 Global Edition Installation Manual Chapter 3 Installing Facility Commander Wnx Global configuration 9 When the Facility Commander Wnx has been successfully installed window opens click Finish 10 Remove the Facility Commander Wnx Installation disc from the CD DVD drive 11 You must license your Facility Commander Wnx Global Edition system at this time Return to the computer that has the Facility Commander Wnx client application component installed 12 The License Setup window opens Proceed to license your system at this time Refer to Licensing your Facility Commander Wnx system on page 108 Database server configuration Components Computer 1 Computer 2 Computer 3 Database server v File server v FCWnx client application v Note This configuration has the database server installed on Computer 1 then the file server and the FCWnx client application are installed on Computer 2 Database server on first computer To install the
60. outside of the normal installation sequence To create the database 1 The Select Database Server Type window opens as shown in Figure 73 Select Regional Database Server and in the Select Global Database Server field select the Global database server for this Regional database server 194 FCWnx 7 7 Global Edition Installation Manual Chapter 4 Install Global Edition Regional configuration Figure 116 Create FCWnx database Select database server type Select Database Server Type i Efe x FCWnx Database Select the database installation option from the list below Global Database Server This option will install a Global Database Server and Distributor SQL Server must already be installed with an instance of SPSQL A z This option will install the Regional Database Server Regional Database Server on a local client A Distributor must be selected from st below Select Global Database Server GLOBAL32BIT SPSQL 2 Click Next The Create Convert Database window opens as shown in Figure 74 Ignore the sa User Name as displayed The Password field displays your previously assigned and encrypted SQL password If you purchased your Facility Commander Wnx system from UTC Fire amp Security a temporary password of SecurityMaster08 case sensitive was assigned for you Accept the password as displayed FCWnx 7 7 Global Edition Installation Manual 195 Chapter 4 Install Global Edition Regional con
61. power on and wait for the computer to restart If the computer does not restart manually restart the system at this time During the boot sequence Windows detects the Digi serial port expander and prompts you for the Windows installation disc FCWnx 7 7 Global Edition Installation Manual 305 Appendix B Optional hardware and software Note If this is a client computer during the boot sequence Windows detects the Digi serial port expander and prompt you for the Windows installation disc 5 Insert the Windows installation disc A screen displays prompting you for the type of module you have attached to the board 6 Select 16em if you are using the 16 port expander box 16em is the default setting or 8em if you are using the 8 port expander box 7 Click Add then Next You are asked what port number you want to install first beginning with the first available COM port usually COM 4 if an internal modem is installed Note We recommend starting with COM 5 ending with COM 20 on a 16em board and COM 12 on an 8em board 8 Click Finish The Ports Configuration window opens 9 Click Next then Finish The installation is complete Shut down and restart the your computer system Following installation of the Digi board 1 Check if the COM ports are installed by clicking Start Programs Administrative Tools then Computer Management 2 In the Computer Management window select Device Manager and expand the Ports COM am
62. procedures to follow when installing optional hardware and software to your FCWnx system Content Installing FCWnx on a thin client terminal server 304 Following installation of FCWnx 304 Setting up a Digi serial port expander 305 Following installation of the Digi board 306 Setting up dial up modems 306 Setting up the Fargo DTC550 printer encoder for smartcard encoding with FCWnx 307 FCWnx 7 7 Global Edition Installation Manual 303 Appendix B Optional hardware and software Installing FCWnx on a thin client terminal server Note Your FCWnx software license limits the number of Thin Client installations allowed Refer to the licensing chapter of your FCWnx Installation Manual Install Thin Client software on the appropriate computers by following the appropriate installation and configuration instructions for your brand of hardware Windows documentation provides additional details of virtual workstation technology and Thin Client services installation and access If you have additional questions consult your IS Department for assistance To install FCWnx on a Thin Client Terminal server computer 1 Insert the FCWnx installation disc into your CD DVD drive A Terminal Server Install Failure dialog opens 2 Click OK The dialog box closes 3 If not already displayed browse to the FCWnx Installation disc content This is typically D 4 Double click Terminal exe to begin the FCWnx software installation 5 Continue with
63. running on page 109 J Configure file replication at the Global database server on page 200 FCWnx 7 7 Global Edition Installation Manual 5 Chapter 1 Introduction to Facility Commander Wnx Prepare and install FCWnx Regional database server Table 3 Steps to prepare and install a Facility Commander Wnx Regional database server 1 Task Reference A Check minimum hardware and software requirements on page 2 B Install network board on page 10 C Determine server type on page 10 D Install prepare Windows operating system on page 11 E Add this server to the primary domain controller of your existing on page 15 or new domain F Install Microsoft SQL Server on page 17 G Prepare and install Facility Commander Wnx software on page 200 H License the system on page 226 Verify that Facility Commander Wnx services are running on page 188 J Configure file replication at the Global database server on page 200 1 Repeat these steps for each Global Regional server computer Prepare and install an FCWnx client computer Note If you are upgrading from a previous version of Facility Commander Wnx software contact Technical Support Table 4 Steps to prepare a Facility Commander Wnx client computer 1 Task Reference A Check minimum hardware and software requirements on page 2 B Install network board on page 10 C Add this server to the primary domain controller of your existing on page 15 or new domain D If using
64. select the Global database server for this Regional database server Figure 79 Create FCWnx database Select database server type aixi FCWnx Database Select the database installation option from the list below e This option will install a Global Database Server and Siobal Database NTE Distributor SQL Seaver must already be installed with an instance of SPSQL ie i This option will install the Regional Database Server Ponionpi paitane Server mi F ma client A Distributor must be selected from ist below Select Global Database Server GLOBAL32BIT SPSQL FCWnx 7 7 Global Edition Installation Manual 141 Chapter 4 Install Global Edition Regional configuration 2 Click Next The Create Convert Database window opens as shown in Figure 80 Ignore the sa User Name as displayed The Password field displays your previously assigned and encrypted SQL password If you purchased your Facility Commander Wnx system from UTC Fire amp Security a temporary password of SecurityMaster08 case sensitive was assigned for you Accept the password as displayed Figure 80 Create Convert Database 3 142 Create Convert Database FCWnx 7 7 Database Collect login information To begin the database create convert process please supply the SQL Server SQL 2008 Express administrators username and password in the following text box es Database Server _ Click Next The Create
65. serveri Video C Frs Staging a Guam Video E Frs Staging Staging Bk f Noe f cca 5 Select the Global Database server as the initial master and click Next The Configure Replication Wizard window opens similar to Figure 132 Figure 132 Configure Replication Wizard Configure Replication Wizard i x The topology controls the direction in which information is replicated between targets Select the topology you want for this replication set Topology Full mesh FCWnx 7 7 Global Edition Installation Manual 211 Chapter 5 Configuring Global Edition for file replication 6 Select Full Mesh as the topology and click Finish 7 When the Master is set and all shared folders are enabled click OK The Distributed File System Snap in displays similar to Figure 133 Figure 133 Distributed File System Snap In with Shared Folders Added and Enabled for Replication Services i Distributed Fle System T E File Action View Help er iene eit Distributed File System 3 boca com Replication Video Designs Externals Firmware 8 Repeat instructions for each additional replica target Note Your FCWnx Global Edition system is now configured for file replication File Replication to process added revised or deleted files can take from five minutes to approximately one hour 212 FCWnx 7 7 Global Edition Installation Manual Chapter 5 Configuring Global Edition for file replication File Replicatio
66. the Domain Controller Active Directory will have permission to start Facility Commander Wnx at all Facility Commander Wnx system computers Verify that the user who is logging on to the computer where Facility Commander Wnx is running is part of the SPAdmin group on the Domain Active Directory You have just completed installation of the Regional database server Now continue with Chapter 5 Configuring Global Edition for file replication on page 199 What s next 1 If you have not already done so remove the Facility Commander Wnx installation disc from your CD DVD drive You have completed the Global setup 2 If you have not licensed your system do so now Refer to Chapter 6 License and Set Security Settings for your FCWnx System on page 225 3 Proceed to set up the additional client computers on your Facility Commander Wnx system Refer to Chapter 8 Installing Facility Commander Wnx Software on additional clients on page 249 Note Following configuration of each new client installation all currently installed Facility Commander Wnx Global Edition server computers and client computers must be restarted in order to be recognized Create FCWnx Database Utility The Create FCWnx Database feature is available on the Facility Commander Wnx program menu of computers with Typical server installed or Custom installation with the database server component installed Select this option if you are creating a database
67. the Global Database creation No action is required on the part of the user Table 7 Order of Events Global database server database creation Step Description 1 The Global database server databases are created SecurePerfect SecurePerfectHistory and SecurePerfectArchive 2 The SecurePerfectDistributor database is installed and enabled 3 The Global database server is configured for publishing The Publisher is identified by the Global database instance name In this installation scenario there is only one Publisher on the Global database instance Refer to Figure 19 on page 42 4 The Facility Commander Wnx Merge Publication is defined To define a publication the database to be replicated is selected Within that publication articles are defined The articles are representative of the tables contained within the database 5 After the Publication is defined the initial Snapshot Agent is started This Agent will create an image of the database at that moment in time Subscribers will utilize this snapshot later 6 The SecurePerfectGlobalHistory database is created This database is only present in the Global database server of a Global Edition installation The following history tables are contained within AlarmHistoryTable BadgeHistoryTable DlHistory DOHistory DVMRHistory GuardTourHistory OperatorHistoryTable SecureAreaHistory ZoneHistoryTable 56 FCWnx 7 7 Global Edition Installation Manual Chapter 3 Installing Facilit
68. the Java code for the Video Monitoring and Control VMC application vmcNis A folder that contains the language support files for the VMC application After the base install of FCWnx these folders are empty as no language kits have been installed yet As the language kits are installed the language support files are placed in this folder Review the folders in your Facility Commander Wnx directory and continue with Facility Commander Wnx user accounts below Facility Commander Wnx user accounts During the Facility Commander Wnx server computer installation a default Facility Commander Wnx local user account was set up for you If you choose to add users and assign or change user passwords refer to Defining user accounts on page 245 Note Default local group is SPAdmin Default local user name is secure and the password is SecurityMaster08 case sensitive Refer to documentation you received when you purchased your Windows 2003 Windows 2008 Windows Vista or Windows XP operating system for additional information on setting up a user and assigning passwords 192 FCWnx 7 7 Global Edition Installation Manual Chapter 4 Install Global Edition Regional configuration Adding a new Global group to the domain Figure 115 SPAdmin Properties window Action View e gt Gla xX E R E Tree General E SPAdmin Description Secure Perfect Local Admin Grou Computer Management Local G N
69. the database snapshot taken by the Snapshot Agent to the Regional database A schedule is updated to operate every day every one minute and set to run As records are added deleted or updated on Regional Servers or the Global database server the changes are replicated to all database Subscribers A new history transactional publication is created on the Regional database server The name of the publication will be similar to the following SecurePerfectHistory SPHistoryPublication A subscription to this publication is created on the Global database server The name of this subscription is Global servername SPSQL SecurePerfectHistory Each Region s history is replicated to the Global database server but it does not redistribute Regional data to another Region History data is a one way replication A new push subscription is created on the Region a snapshot is started and the Transactional Agent is run Note For each history publication on the Regional server there is a corresponding subscription on the Global server while the SecurePerfect database publication has multiple subscribers 5 A message opens FCWnx Database successfully created Note A log file is created when the Create Database program is run The log file called CreateDatabaseLog is found in the Logs folder The Integrity utility runs automatically following a database creation No user interaction is required Refer to your Facility Commander Wnx O
70. the snapshot of the Global database the snapshot is applied to the Regional database server database FCWnx 7 7 Global Edition Installation Manual 197 Chapter 4 Install Global Edition Regional configuration Step Description The Merge Agent is started at the Global database server This agent on its initial creation applies the database snapshot taken by the Snapshot Agent to the Regional 5 database A schedule is updated to operate every day every one minute and set to run As records are added deleted or updated on Regional Servers or the Global database server the changes are replicated to all database Subscribers A new history transactional publication is created on the Regional database server The name of the publication will be similar to the following SecurePerfectHistory SPHistoryPublication A subscription to this publication is created 6 on the Global database server The name of this subscription is Global servername SPSQL SecurePerfectHistory Each Region s history is replicated to the Global database server but it does not redistribute Regional data to another Region History data is a one way replication A new push subscription is created on the Region a snapshot is started and the Transactional Agent is run Note For each history publication on the Regional server there is a corresponding subscription on the Global server while the SecurePerfect database publication has multiple subscribe
71. this folder A shared folder that contains all credential designs used by the imaging stations and sample credential designs The files required to display the Facility Commander Wnx client software in English As more languages are installed more language specific folders display A shared empty shared folder created to store reports created by third party report generator A shared folder that contains the firmware or application code needed to flash the controllers A folder that contains the language support files for the GMC application After the base install of FCWnx these folders are empty as no language kits have been installed yet As the language kits are installed the language support files are placed in this folder A shared folder that contains the working data files for the GMC application A shared folder that contains the Facility Commander Wnx diagnostic log files A folder that contains files used by the report engine to create Facility Commander Wnx reports The scripts and programs used to create the database in SQL Server It also contains subfolders required for converting and upgrading to Facility Commander Wnx A folder that contains the FCWnx and GMC User Manuals in pdf format An empty shared folder created to store video files and JPG image files grabbed from video windows A folder that contains the dlls that enable communication between FCWnx and VMC A folder that contains the Java code f
72. time lt i ms TTL 128 Reply from 3 18 145 1 4 bytes 32 time lt i ms TTL 128 Reply from 3 18 145 104 bytes 32 time lt 1 ms TTL 128 Reply from 3 18 145 104 bytes 32 time lt i ms TTL 128 Ping statistics for 3 18 Packets Sent 4 Rece Lost x loss i i i milli seconds Minimum ms Maximum gt Average Gms GSN Pan Unsuccessful If the computer could not be reached your window will display similar to Figure 147 below Verify your network settings as configured during the operating system setup on page 241 or contact your network administrator for assistance Figure 147 Unsuccessful ping to server computer INNT System32 cmd exe t Windows 2000 Version 5 00 2195 kos Copyright 1985 2000 Microsoft Corp H gt ping bct creed passi Pinging bct creed passi 3 118 145 157 with 32 bytes of data Request timed out Request timed out Request timed out Request timed out Ping sta tics for 3 18 145 157 Pac Sent 4 Received Lost ie 168 loss Approximate round trip times in milli second inimum ms Maximum ms Average Tns IH gt Note You cannot proceed until the networking issues are resolved FCWnx 7 7 Global Edition Installation Manual 251 Chapter 8 Installing Facility Commander Wnx Software on additional clients Checking computer accessibility over the network Another method for checking access to the computer is by using a Run
73. to About Facility Commander Wnx license summary on page 232 What s next 1 If you have not already done so remove the Facility Commander Wnx installation disc from your CD DVD drive You have completed the Global setup 2 If you have not licensed your system do so now Refer to Chapter 6 License and Set Security Settings for your FCWnx System on page 225 Note Following configuration of each new client installation all currently installed Facility Commander Wnx Global Edition server computers and client computers must be restarted in order to be recognized FCWnx 7 7 Global Edition Installation Manual 223 Chapter 5 Configuring Global Edition for file replication 224 FCWnx 7 7 Global Edition Installation Manual Chapter 6 License and Set Security Settings for your FOWnx system Summary This chapter details procedures to follow when licensing your new Facility Commander Wnx system Follow instructions in the sequence presented REMINDER Keep in mind that you may have to return to a previous section of this Manual to continue the installation sequence following the licensing process Content Licensing Facility Commander 226 Generating a registration key 227 Entering the license key 227 About Facility Commander Wnx license summary 232 SecurityCnfg Utility 234 What s next 237 FCWnx 7 7 Global Edition Installation Manual 225 Chapter 6 License and Set Security Settings for your FCWnx System Li
74. to Adding a new user account on page 113 e Be prepared to license your software for Global configuration Adding the computer to a domain Since the server computer will be part of a new or existing domain you must add the server computers to the network Network configuration varies from company to company see your network administrator for assistance It is important that the Server and Client system use the same network properties Refer to Setting the network properties on page 13 and Setting the network properties on page 243 for more information or consult with your network administrator Adding SQL Server and SQLServerAgent services to a domain In Windows services the SQL Server SPSQL and SQL Server Agent services must use a domain account The SQLAgent account is the security context under which the Snapshot Agent Merge Agent and Distribution Agent are running by default To change from the LocalSystem Windows Service Account to an existing domain account 1 Click Start and then click Control Panel Category view Click System and Maintenance and then click Administrative Tools Classic view Double click Administrative Tools 2 Double click Services 3 From the list of Services Local select SQL Server SPSQL and then right click to display the shortcut menu 4 From the shortcut menu select Properties The General tab of the Properties window opens 5 If the service is runni
75. vendors of the respective products Use this product only for the purpose it was designed for refer to the data sheet and user documentation for details For the latest product information contact your local supplier or visit us online at www utcfireandsecurity com This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications You are cautioned that any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment CE 2002 96 EC WEEE directive Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union For proper recycling return this product to your local supplier upon the purchase of equivalent new equipment or dispose of it at designated collection points For more information see www recyclethis info UTC Fire amp Security HQ and regulatory responsibility UTC Fire amp Security 9 Farm Springs Road Farmington CT 06034 4065 USA For contact information see our Web site www utcfir
76. with your IT department for company specific network settings Refer to SecurityCnfg Utility on page 234 for more details on using this utility After successfully configuring the security settings 1 You may receive a Facility Commander Wnx Installation Complete dialog box If so click Yes to restart your computer 108 FCWnx 7 7 Global Edition Installation Manual Chapter 3 Installing Facility Commander Wnx Global configuration 2 Log on as administrator and continue with Setting services to automatic startup below Setting services to automatic startup Now you need to change the startup method of the FCWnx services to automatic This means every time the computer starts the Facility Commander Wnx services start Refer to Facility Commander Wnx services overview on page 266 for additional information about Facility Commander Wnx Services Note At this point in the installation the Facility Commander Wnx services are stopped Only Global database server installation No services are installed at this point if this is a custom installation and Facility Commander Wnx client application is not yet installed To set the startup method of Facility Commander Wnx Services 1 Click Start Control Panel Administrative Tools and then Services The Services window displays Expand the list of services and scroll down Figure 60 FCWnx component services Services aiii View Help e Osalbml gt euo
77. 0 Chapter 4 Install Global Edition Regional configuration 121 Preinstallation checklist 122 Installation 124 Custom installation Regional database server 126 Database server file server and FCWnx client application configuration 130 Database server and file server configuration 138 Database server and FCWnx client application configuration 150 Database server configuration 161 Each component on a separate computer 173 Licensing your Facility Commander Wnx system 187 Configuring security settings 187 Setting services to automatic startup 188 Setting services to automatic startup 188 Server folder structure 190 Facility Commander Wnx user accounts 192 What s next 194 Create FCWnx Database Utility 194 Chapter 5 Configuring Global Edition for file replication 199 Configuring file replication services 200 File Replication on Windows 2003 with SQL 2005 201 File Replication on Windows 2008 with SQL 2008 213 Adding additional clients to the database 220 What s next 223 Chapter 6 License and Set Security Settings for your FCWnx System 225 Licensing Facility Commander 226 About Facility Commander Wnx license summary 232 SecurityCnfg Utility 234 What s next 237 Chapter 7 Windows 7 Vista and XP Professional system setup 239 Preinstallation checklist 240 Network card 240 Configure the computer for the network 241 Installing the operating system 242 Setting up your monitor 242 Setting the network prope
78. 1 and then the file server and the FCWnx client application are installed on Computer 2 Database server on first computer To install the database server on the first computer 1 On the FCWnx Global Custom Configuration window select Database Server and Regional as shown in Figure 93 Figure 93 Fewnx Global Custom Configuration Regional database server te Facility Commander Wnx 7 7 Setup FCVvnx Global Custom Configuration O Choose the appropriate components for a custom Global Edition installation IV Database Server Choosing this option will install the FC Wnx database components Please select which type of server Global Only one of these per FCWnx Global Edition installation Regional There can be several of these for an FCWnx Global Edition installati I Fie Server Choosing this option will install the FCwnx File Server components I FCWnx Client Application Choosing this option will install the FCWnx Client Application Wise Installation Wizard Cea FCWnx 7 7 Global Edition Installation Manual 161 Chapter 4 Install Global Edition Regional configuration 2 Click Next The Global Database and FileServer Paths window opens as shown in Figure 94 Figure 94 File Server Name Required 3 162 i Facility Commander Wax 7 7 Setup oa O x Global Database and FileServer Paths Global Database Server Name z File Server Name N Wise Installation Wizard
79. 337 14 To start your CCTV interface click Launch Client on the toolbar while the CCTV interface is selected This starts the program that communicates with your CCTV switcher Configuring alarms The communication between the FCWnx system and the Pelco system is bidirectional meaning that alarms are sent from FCWnx to the Pelco system and alarms are also sent from the Pelco system to the FCWnx system Alarms from the Pelco system There is one alarm that can be generated from the Pelco CCTV system Loss of COMM Alarm This alarm signifies that the interface program is no longer able to communicate with the Pelco controller Alarms from FCWnx The FCWnx Pelco interface allows FCWnx alarms to trigger CCTV cameras monitors to turn on or off on the Pelco system Before this can happen FCWnx needs to be notified as to which FCWnx alarms are to be the triggers and which messages need to be sent to the Pelco system to trigger cameras monitors To configure correctly follow the steps below Each step is explained in more detail in the sections that follow 1 Add change or delete the desired CCTV alarms Adding changing or deleting CCTV alarms below 2 Map FCWnx alarms to CCTV alarms See Mapping FCWnx alarms to CCTV alarms on page 337 Adding changing or deleting CCTV alarms CCTV alarms are the actual messages that are sent out to the Pelco interface They control what sequence of monitors and cameras are s
80. Agent account is the security context under which the Snapshot Agent Merge Agent and Distribution Agent are running by default To change from the LocalSystem Windows Service Account to an existing domain account 1 Click Start and then click Control Panel Category view Click System and Maintenance and then click Administrative Tools Classic view Double click Administrative Tools 2 Double click Services 3 From the list of Services Local select SQL Server SPSQL and then right click to display the shortcut menu 4 From the shortcut menu select Properties The General tab of the Properties window opens Click Stop under Service status Select and display the Log On tab Select This account The field for account name is now enabled o N O oO Enter the name of the domain account that will start and stop SQL services or click Browse to navigate the Windows network and select the name of the domain account 9 Enter the password for the domain account and then enter the password again to confirm 10 Return to the General tab and verify that Startup type is set to Automatic 11 Click Start under Service status 12 Click OK to accept and close the window 13 From the list of Local Services select SQL Server Agent SPSQL and then right click to display the shortcut menu 14 Repeat step 3 through step 11 15 Continue with Installation FCWnx 7 7 Global Edition Installation Manual 123 Chapter 4 I
81. CWnx 7 7 Global Edition Installation Manual 283 Chapter 11 Back up your Global Edition Click Start Programs Microsoft SQL Server 2005 or 2008 then SQL Server Management Studio At the Connect to Server window verify that the Login and Password are correct then click Connect Navigate to and open the Databases folder This procedure may take several minutes Note Although there are other methods we have included the following steps as a guide to assist you in performing one type of backup To back up your database 1 O a A OOD Right click the database SecurePerfect SecurePerfectArchive SecurePerfectHistory or SecurePerfectGlobalHistory you want to back up The shortcut menu displays Click Tasks Back Up The Backup Database dialog box displays Inthe Backup type drop down box select Full Inthe Name field you can keep the default or choose a different name Under the Destination you can choose either disc or Tape Edit the file path name as appropriate for the folder that you have created to receive the database Do not change the database name Click OK If backing up e The SecurePerfect database DO NOT change the database name e Either SecurePerfectArchive SecurePerfectHistory or SecurePerfectGlobalHistory you change the file name each time you back up or the file is overwritten Note We recommend that you select the device or a file on a network 7 Inthe Select a page
82. Click Back to change any of the settings or click Install to continue 24 An Installing Microsoft SQL Server window opens briefly and automatically moves on to Setup Progress as shown in Figure 8 24 FCWnx 7 7 Global Edition Installation Manual Chapter 2 Windows Server 2003 2008 Standard and Enterprise Edition Server setup Figure 8 Setup Progress Microsoft SQL Server 2005 Setup Ee xj Setup Progress The selected components are being configured d Status Qmsxmis Setup finished Qsar Setup Support Files Setup Finished Qsoa Native Client Setup finished Q SQL v55 Writer Setup finished OWC11 Setup finished so Server Backward Compatibility Files Setup finished P SQL Server Database Services Configuring components Visual Studio Integrated Development gt Status Writing system registry values HGRERGRRERRRERERR GRR 25 A checklist displays as components are configured and validated A status column indicates the progress Note This process takes quite some time During the process a message displays requesting that you insert Disc 2 of the SQL Server 2005 Insert Disc 2 and click OK Please wait This does not apply if you are installing from a DVD 26 When the process is finished click Next 27 A Completing Microsoft SQL Server 2005 Setup window opens A list of setup logs displays sources of information describing the configuration Review the list and click Finish to exit the
83. Click Next When the License Agreement window opens select accept the license agreement and click Next Select the type of installation as Custom and then click Next The Custom Configuration window opens as shown in Figure 92 Select File Server FCWnx 7 7 Global Edition Installation Manual 159 Chapter 4 Install Global Edition Regional configuration Figure 92 FCWnx Global custom configuration file server ii Facility Commander Wnx 7 7 Setup SS ioj x FCVvnx Global Custom Configuration SoS Choose the appropriate components for a custom Global Edition installation Database Serves _____________ Choosing this option will install the FCWnx database components Please select which type of server Global Only one of these per FCWnx Global Edition installation Regional There can be several of these for an FOWnx Global Edition installation IV File Server Choosing this option will install the FCWnx File Server components I FCWnx Client Application Choosing this option vall install the FCWnx Client Application Wise Installation Wizard Click Next The Change the Secure password window opens The Facility Commander Wnx installation creates a new Windows User ID called secure By default the password is SecurityMaster08 case sensitive If your Windows network has security policies that enforce rules for password creation you may need to change the secure user pass
84. CreateDatabaseLog is found in the Logs folder The Integrity utility runs automatically following a database creation No user interaction is required Refer to your Facility Commander Wnx Online Help for addition information about the Integrity utility 7 Click OK The dialog box closes If you receive a message to restart at this time click Yes to restart log on and continue An FCWnx License Setup window opens Unless otherwise stated in your configuration scenario proceed to Licensing your Facility Commander Wnx system on page 108 Note Be sure to complete all instructions for the scenario you are installing File server and FCWnx client application on second computer Now you must install file server and FCWnx client application on a separate Windows 2003 or 2008 Standard server computer Note Prerequisite database server installation already complete To install required components Verify that the computer you are configuring meets minimum requirements FCWnx 7 7 Global Edition Installation Manual 87 Chapter 3 Installing Facility Commander Wnx Global configuration Insert the FCWnx installation disc into the CD DVD drive When prompted click Run autorun exe If the disc does not launch you must manually start the software Using Windows Explorer navigate to the FCWnx Installation disc and then double click autorun exe 3 The Facility Commander Wnx Main Menu opens Click Install FCWnx v7 7
85. DIP switch settings They should be set to the default value Refer to your Burle Allegiant documentation for setup specifics For the FCWnx system e FCWnx computer See Installation Burle Allegiant on page 321 for installation instructions Atleast one serial port or two if you plan on using the optional Video Loss monitoring You may need to purchase and install a Digi board to provide additional COM ports to connect to the switchers e Cable to connect the FCWnx system to the Burle Allegiant switcher console port See Figure 165 on page 321 and Figure 166 on page 321 e For the optional Video Loss monitoring a second RS 232 C serial port 320 FCWnx 7 7 Global Edition Installation Manual Figure 165 Cable pinouts FCWnx system to switcher DB25F to DB9M FCWnx System Switcher Digi Board DB25F DB9M Tx RTS SGND CTS rn WwW N Tx 2 Rx 3 cTs 5 SGND 7 DCD 8 DSR 6 DTR 20 Figure 166 Cable pinouts FCWnx system to switcher DB9F to DB9M FCWnx System Switcher DB9F DB9M Tx 3 2 Rx Rx 2 3 Tx cis 8 5 RTS SGND 5 7 SGND DCD 1 4 CTS DSR 6 DTR 4 Installation Burle Allegiant This interface program has a separate install utility in the FCWnx directory of the client computer or in the client directory of the server computer The FCWnx Burle Allegiant program can be installed at the same time the FCWnx system is installed or any time thereafter Note Refer to your Burle Allegiant manual for DIP
86. Database View Intearity Report ck ee oee 4 Click Create Database The database creation begins and a progress bar is displayed This may take a few minutes Caution If a database already exists a warning message will display stating that you are about to overwrite your existing database with an empty default database Order of events Regional database server database creation For information only this is the order of events taking place during the Regional database server database creation No action is required on the part of the user Table 19 Order of Events Regional database server database creation Step Description The Regional database server database is created SecurePerfect l SecurePerfectHistory and SecurePerfectArchive 178 FCWnx 7 7 Global Edition Installation Manual Chapter 4 Install Global Edition Regional configuration Step Description The Regional database server contacts the SecurePerfectDistributor and Publisher on the Global database server The Regional database is added to the Subscriber s list at the Publisher and a new push subscription is created The Snapshot Agent is started at the Global Database server computer When the 4 agent completes the snapshot of the Global database the snapshot is applied to the Regional database server database The Merge Agent is started at the Global database server This agent on its initial creation applies
87. Database Initialize the Database Creation window opens as shown in Figure 91 Each Facility Commander Wnx database consists of data files and transaction logs You have an option to place those components in different physical locations You may consider this if your IT Department has certain policies regarding database installation Consult with your IT Department for assistance Data File Directory The Data File Directory field displays the default directory Accept the default as displayed or click the Browse button and browse to any folder location where data files will be stored Note If you are installing in a Cluster configuration the Distributor installs to the same path as the Cluster Data File directory Log File Directory The Log File Directory field displays the default directory Accept the default or click the Browse button and browse to the folder location where database log files will be stored Note This refers to the database logs this does NOT refer to the Facility Commander Wnx logs FCWnx 7 7 Global Edition Installation Manual Chapter 4 Install Global Edition Regional configuration Figure 91 Create Database Create Database es 5 xj FCWhnx 7 7 Database Initialize the database creation Q Log View Error m Database Directory Information _ ___ __ C Program Files GE FCWnx Database ae Log File Directory ram Filas GE FCWnx D
88. Edition for file replication 4 Select Domain root option and then click Next The Host Domain window opens with the Domain name displaying in the dialog box similar to Figure 121 Figure 121 Host Domain New Root Wizard xj Host Domain 4 domain can host multiple DFS roots Type the domain to host the root or select it from the list of trusting domains Domain name Trusting domains boca com lt Back Cancel 5 Verify that the Domain name is accurate A domain can host multiple Dfs roots Click Next The Host Server window opens similar to Figure 122 FCWnx 7 7 Global Edition Installation Manual 203 Chapter 5 Configuring Global Edition for file replication Figure 122 Host Server New Root Wizard Host Server Enter the name of the host server for this root aoa 6 Enter the host server computer name in the Server name dialog box or click Browse to navigate to the correct server computer The server computer that you select must have FCWnx installed before configuring for file replication Click Next and the Root Name window opens similar to Figure 123 204 FCWnx 7 7 Global Edition Installation Manual Chapter 5 Configuring Global Edition for file replication Figure 123 Root Name New Root Wizard x Root Name You must provide a unique name for each DFS root Type a unique name for this root Root name Replication Preview of UNC path to the root
89. FCWnx 7 7 Global Edition Installation Manual Z UTC Fire amp Security A United Technologies Company P N 460648003A O9AUG11 Copyright Disclaimer Trademarks and patents Intended use FCC compliance Certification and compliance Manufacturer Contact information 2011 UTC Fire amp Security All rights reserved This document may not be copied in whole or in part or otherwise reproduced without prior written consent from UTC Fire amp Security except where specifically permitted under US and international copyright law The information in this document is subject to change without notice UTC Fire amp Security assumes no responsibility for inaccuracies or omissions and specifically disclaims any liabilities losses or risks personal or otherwise incurred as a consequence directly or indirectly of the use or application of any of the contents of this document For the latest documentation contact your local supplier or visit us online at www utcfireandsecurity com This publication may contain examples of screen captures and reports used in daily operations Examples may include fictitious names of individuals and companies Any similarity to names and addresses of actual businesses or persons is entirely coincidental The Facility Commander Wnx name and logo are trademarks of UTC Fire amp Security Other trade names used in this document may be trademarks or registered trademarks of the manufacturers or
90. Facet list and select Surface Area Configuration 5 In the Facet properties area select the AdhocRemoteQueriesEnabled and make it True to enable OPENROWSET amp OPENDATASOURCE as shown in Figure 18 on page 38 6 Click OK 7 Exit the SQL Server Management Studio FCWnx 7 7 Global Edition Installation Manual 37 Chapter 2 Windows Server 2003 2008 Standard and Enterprise Edition Server setup Figure 18 Enable OPENROWSET and OPENDATASOURCE B View Facets KAN XPSA SPSQL General Surface Area Configuration Description Surface area configuration for Features of the Database Engine Only the features required by your application should be enabled Disabling unused Facet properties mE AdHocRemoteQueriesEnabled True ClrIntegrationEnabled False DatabaseMailEnabled False OleAutomationEnabled False RemoteDacEnabled False ServiceBrokerEndpointactive False SoapEndpointsEnabled False SqlMailEnabled False WebAssistantEnabled Property value WebAssistantEnabled is not avai S KAN xPSA SPSQL xPCmdShellEnabled False GEINDSYS AMER 414001298 View connection properties AdHocRemoteQueriesEnabled The OPENROWSET and OPENDATASOURCE functions support ad hoc connections to remote data sources without linked or remote servers Enable these Functions only if your applica l Export Current State as Policy OK Cancel Help Cluster environment Contact the Enterprise Services Department of UTC
91. Facility Commander Wnx Logging on Note Default login ID is secure and the password is SecurityMaster08 case sensitive The language is English To log on to the Facility Commander Wnx application 1 Select the File menu and then Login 2 Enter your login ID and password If this is a client machine the server computer must be installed configured and licensed The Facility Commander Wnx services must be running on the server computer 3 Click OK Note If logging onto Facility Commander Wnx using a client you must have a valid user name and password along with a valid Facility Commander Wnx login ID and password on the server computer Those login IDs must be part of the SPAdmin local group on the Facility Commander Wnx server computer Accessing help To access the Help System select Help Topics from the Facility Commander Wnx Help menu You do not have to be logged in to access Help Figure 156 Accessing the help system Help Help Topics FcWnx User Manual i About FCWnx 270 FCWnx 7 7 Global Edition Installation Manual Chapter 9 Logging on and configuring Facility Commander Wnx Defining additional user accounts Adding Windows users is optional but recommended since this clearly identifies each user in Windows Note If you do choose to add users you must assign them to the group SPAdmin after Facility Commander Wnx is installed Adding yourself as an operator in Facility Comma
92. Facility Commander Wnx Refer to Chapter 9 Logging on and configuring Facility Commander Wnx on page 265 e FCWnx License Refer to Licensing Facility Commander on page 226 e Security Configuration Refer to SecurityCnfg Utility on page 234 Viewing Imaging status To verify whether you currently have Imaging capabilities 1 Log on to Facility Commander 2 From the Application Group pane select Monitors amp Controls then Client Monitor The number of Imaging licenses purchased with your system displays in a lower section of the form Note Keep in mind that Imaging installs on all computers in your Facility Commander Wnx system Your Facility Commander Wnx license controls the number of Imaging stations active at the same time 3 Select a client computer from the list displayed then right click to display the shortcut menu 4 Select Client from the shortcut menu The Client Form opens displaying the record for the selected client 5 Select Imaging Status as Enabled and click Save The photo ID badging system is now enabled for use at this station Imaging login setup If the operator that is running Facility Commander Wnx and Imaging system is not a member of the local Administrator s group you must add the Power Users FCWnx 7 7 Global Edition Installation Manual 261 Chapter 8 Installing Facility Commander Wnx Software on additional clients group to this account The operator login should belo
93. If you see any other files select them and click Delete 3 Next continue with Deleting subkeys from the registry below Deleting subkeys from the registry Caution Using the Registry Editor incorrectly can cause serious problems that may require you to reinstall your operating system Neither UTC Fire amp Security nor Microsoft guarantee that problems resulting from the incorrect use of Registry Editor can be solved Use Registry Editor at your own risk To delete the FCWnx subkey from the registry 1 Click Start then Run FCWnx 7 7 Global Edition Installation Manual 295 Chapter 13 Troubleshooting maintenance support In the Run window enter regedit Click OK Locate the HKEY_LOCAL_MACHINE key Double click the SOFTWARE icon to expand the folder tree If you find a GE key in this folder double click the GE key to expand the folder tree Ora Sol ES er TO 7 If you find an FCWnx key right click the key and then click Delete e If you have a problem deleting the FCWnx key you may need to change the registry permission Refer to Changing registry permissions below e If you do not have an FOWnx or a GE key this is an indication that the uninstall was successful in updating the Registry Continue with step 8 You are asked to confirm the deletion 8 Click Yes 9 From the main menu select Registry then Exit 10 Restart your computer at this time Changing registry permissions If you have an
94. Installation Wizard 28 We recommend that you restart your computer at this time FCWnx 7 7 Global Edition Installation Manual 25 Chapter 2 Windows Server 2003 2008 Standard and Enterprise Edition Server setup Install SQL 2005 Service Pack 3 1 Insert the FCWnx Windows Updates disc into the CD DVD drive 2 Navigate to the SQL Server 2005 SP3 folder 3 Double click on the file SQLServer2005SP3 KB955706 x86 ENU exe 32 bit or SQLServer2005SP3 KB955706 x64 ENU exe 64 bit 4 Follow the on screen instructions When prompted make sure that you select the SPSQL instance 5 We recommend that you restart your computer at this time Setting SQL Server Agent properties By default the SQL Server Agent service is disabled when SQL Server 2005 is installed This service must be running to keep the databases in optimal condition Note See step 17 on page 22 If you selected SQL Server Agent on the Service Account window you do not have to set Server Agent properties at this time 1 Right click My Computer on your desktop and select Manage 2 Inthe Computer Management window expand Services and Applications and then expand Services to display the list of services on your computer 3 Select and right click SQL Server Agent SPSQL where SPSQL is used in this example Select Properties to open the Properties window In the Startup type select Automatic from the drop down list Click OK We recommend that you restart you
95. KEY CardMan_Synchronous_API_V1_1_1_4 Browse to this folder and then run the setup exe You can verify this is installed by opening Add Remove programs FCWnx 7 7 Global Edition Installation Manual 309 Appendix C CCTV Interfaces Summary This appendix provides information for installation and configuration of CCTV interfaces Content Overview 312 Software requirements 312 American Dynamics system 313 Setup overview 313 Hardware requirements 314 Installation American Dynamics 315 Configuring alarms 316 Adding changing or deleting CCTV alarms 317 Burle Allegiant system 318 Setup overview 319 Hardware requirements 320 Installation Burle Allegiant 321 Configuring alarms 323 Adding changing or deleting CCTV alarms 324 Kalatel system 325 Setup overview 325 Hardware requirements 326 Installation Kalatel 327 Configuring alarms 329 Adding changing or deleting CCTV alarms 329 Pelco system 331 Setup overview 331 Hardware requirements 332 Installation Pelco 333 Appendix C CCTV Interfaces Configuring alarms 335 Alarms from the Pelco system 335 Alarms from FCWnx 335 Adding changing or deleting CCTV alarms 335 Mapping FCWnx alarms to CCTV alarms 337 Monitoring 337 Diagnostics 338 Removal of CCTV client interface 338 Overview The CCTV Interface system operates separately from FCWnx and requires its own hardware and software This document details the process of installing CCTV interfaces in
96. L Server Click OK to begin installing the components 4 When the NET Framework Welcome to Setup window opens review the agreement select have read and ACCEPT the terms of the License Agreement and then click Install 5 When the process is complete the NET Installation complete window opens click Exit FCWnx 7 7 Global Edition Installation Manual 29 Chapter 2 Windows Server 2003 2008 Standard and Enterprise Edition Server setup 6 The Windows Update Standalone Installer window opens click OK to install Windows software updates 7 A popup window opens indicating that the installation is complete click Restart Now 8 After the computer has been restarted log on as Administrator using your Administrator password 9 You must restart the SQL Server 2008 installation again by either of the following methods e Open and close your CD DVD drive to initialize setup e Using Windows Explorer navigate to the CD DVD drive and double click Setup exe 10 The SQL Server Installation Center window opens Click Installation and then click New SQL SERVER stand alone installation or add features to and existing installation as shown in Figure 12 below Figure 12 SQL Server Installation Center E SQL Server Installation Center loj x Planning lt Q New SOL Server stand alone installation or add features to an existing installation Installation Launch ay izard to install SQL Server 2008 in a non clustered environment or to
97. Launch Client on the toolbar while the CCTV interface is selected This starts the program that communicates with your CCTV switcher Configuring alarms The communication between the FCWnx system and the American Dynamics system is a one way communication FCWnx only sends data to the American 316 FCWnx 7 7 Global Edition Installation Manual Dynamics switcher it does not receive any messages from American Dynamics If the American Dynamics switcher loses communications with the FCWnx system there is not be a Loss of COMM alarm generated on the FCWnx system Only the loss of Client COMM alarm is installed in the American Dynamics interface This alarm is generated from FCWnx when the FCWnx server is no longer able to communicate with the interface program Alarms from FCWnx The FCWnx American Dynamics interface allows FCWnx alarms to trigger CCTV cameras monitors to turn on or off on the American Dynamics system Before this can happen FCWnx needs to be notified as to which FCWnx alarms are to be the triggers and which messages need to be sent to the American Dynamics system to trigger cameras monitors To configure correctly follow the steps below Each step is explained in more detail in the sections that follow 1 Add change or delete the desired CCTV alarms Adding changing or deleting CCTV alarms below 2 Map FCWnx alarms to CCTV alarms See Mapping FCWnx alarms to CCTV alarms on page 337 Adding chan
98. MF COMMON B BL BLACK KTD 304 D KEYPAD 530119006A e FCWnx computer Refer to Installation Kalatel below e Cable to connect the FCWnx system from Kalatel KTD 348 Figure 169 Cable pinouts FCWnx to Kalatel KTD 348 ALRT RS 232 OUT IN Peco ee ee hel SE om RX TX B A B A HH HHHH DB 9 PIN SIGNAL DB 25 PIN 2 RXD 3 3 TXD e 2 l 5 GND 7 530119005A Installation Kalatel This interface program has a separate install utility in the FCWnx directory of the client computer or in the Client directory of the server computer Appendix C CCTV Interfaces The FCWnx Kalatel program can be installed at the same time the FCWnx system is installed or any time thereafter Note Refer to your Kalatel manual for DIP switch settings They should be set to the default settings To install FCWnx Kalatel 1 You must be logged in to the FCWnx computer with administrator privileges If not log out and log back in Note The client on which you are installing FCWnx must be able to communicate on the network with the License Domain Controller 2 Click Start then Run 3 From the Run window click Browse 4 In the Look in field select the hard drive on which FCWnx is loaded such as CoN O O 12 328 C Then navigate to the directory FCWnx is installed The default is Program Files GE FCWnx Select the CCTVInstall exe Click Open
99. Next to display the Select Credential Aliasing Option window This feature allows you to assign a credential number that represents the encoded credential number This provides added security in that the encoded number is only displayed to authorized users e Do not use aliases indicates no aliasing will be used e Use aliases automatically provided by FCWnx assigns the credential number for you e Use aliases manually provided by user aliasing allows you to assign the number 10 Choose one aliasing option then click Next The Change the Secure password window opens 82 FCWnx 7 7 Global Edition Installation Manual Chapter 3 Installing Facility Commander Wnx Global configuration 11 The Facility Commander Wnx installation creates a new Windows User ID called secure By default the password is SecurityMaster08 case sensitive If your Windows network has security policies that enforce rules for password creation you may need to change the secure user password If you are unsure ask your system administrator Select one of the following on the Change the Secure password window e Use Default Password e Change Password If you select this option enter your new password and then enter a second time 12 Click Next The Ready to Install the Application window opens 13 Enter the SQL Server password for the sa user This password was previously created during installation of SQL Refer to Installing Micros
100. Note You cannot proceed until the networking issues are resolved Contact your network administrator 4 Continue with Adding clients to the database on page 222 Figure 143 Unsuccessful ping to server computer INNT System32 cmd exe Windows 2000 Version 5 00 2195 kos ra ight 1985 2000 Microsoft Corp H gt ping bct creed passi Pinging bct creed passi 3 18 145 157 with 32 bytes of data Request timed out Request timed out timed out timed out Sent 4 Receive Lost A 106 loss round trip times in milli secon Minimum ms Maximum ms Average ans FCWnx 7 7 Global Edition Installation Manual 221 Chapter 5 Configuring Global Edition for file replication Adding clients to the database You need to add all client computers to your Facility Commander Wnx database that will be in your Facility Commander Wnx system To do this log on and start the Facility Commander Wnx application To add clients to the Facility Commander Wnx database 1 When you have installed and licensed the Facility Commander Wnx application for the first time this is the First Time License computer start the Facility Commander Wnx application by double clicking the Facility Commander Wnx desktop icon e Typical Installation The server computer is the First Time License computer and you can add clients at the server computer e Custom Installation The components required to license may be stored on two s
101. QL Server SQL 2008 Express administrators username and password in the following text box es 3 Click Next The Create Database Initialize the Database Creation window opens as shown in Figure 75 Each Facility Commander Wnx database consists of data files and transaction logs You have an option to place those components in different physical locations You may consider this if your IT Department has certain policies regarding database installation Consult with your IT Department for assistance Data File Directory The Data File Directory field displays the default directory Accept the default as displayed or click the Browse button and browse to any folder location where data files will be stored Note If you are installing in a Cluster configuration the Distributor installs to the same path as the Cluster Data File directory Log File Directory The Log File Directory field displays the default directory Accept the default or click the Browse button and browse to the folder location where database log files will be stored Note This refers to the database logs this does NOT refer to the Facility Commander Wnx logs FCWnx 7 7 Global Edition Installation Manual 135 Chapter 4 Install Global Edition Regional configuration Figure 75 Create Database Create Database FCWhnx 7 7 Database Initialize the database creation Q View Error Log SE FCWrx Database E FCVWinx
102. Sections of this chapter include instructions specific to either Windows 2003 Server or Windows 2008 Server When assigning a server type choose Stand alone or Member Set the network properties Set monitor resolution to a minimum of 1024 by 768 pixels Install MS SQL Server 2005 or MS SQL Server 2008 If you have installed Windows 2003 Server then install MS SQL Server 2005 If you installed Windows 2008 Server then install MS SQL Server 2008 You must have SQL Server installed prior to installing Facility Commander Wnx software In Server and Client Tools you must enter SPSQL in the Instance Name field SQL Server Agent must be running to keep the databases in optimal condition Note You may experience other behavior based on the version of Windows you have installed These are guidelines and these instructions are based on a sample configuration FCWnx 7 7 Global Edition Installation Manual 9 Chapter 2 Windows Server 2003 2008 Standard and Enterprise Edition Server setup Network card Note If you purchased this system from UTC Fire amp Security the network card is installed for you If it is not already installed install the network card now Follow the instructions included with the board Verify that you are using the same network card speed as the existing network Refer to the Microsoft Installation Guide for details of a network card configuration or obtain information at www microsoft
103. Service e FCWnx WCF Service Note FCWnx API Service is used when an external system is sending or receiving transactions by way of an Application Program Interface API to FCWnx 7 When all services are configured close all windows and applications 8 Restart the Facility Commander Wnx server computer Continue with Server folder structure below Server folder structure During installation of the Facility Commander Wnx software the folders shown in Figure 61 on page 111 and listed in Table 12 on page 112 are created The folders displayed in your FCWnx folder the default is Program Files GE FCWnx vary with the type of installation If Typical Server type is selected all folders are present If Custom Server Type is installed and only the Database server feature is installed the following folders are present e Database e SecureScripts e gmcNis vmcNis e Logs File server feature is installed the following folders are present e Designs e gmcNis e Externals e Logs e Firmware e Video e vmcNis FCWnx client application is installed the following folders are present e Config e Logs 110 FCWnx 7 7 Global Edition Installation Manual Chapter 3 Installing Facility Commander Wnx Global configuration English e Rpt gmcNls e UserManuals GraphicsCache VideoSubsystem jre e Vmc Vmenls Some of the folders are shared Refer to the example in Figure 61 below This allows other computers to gain access t
104. System Pelco CM3760 DT Box DB9F DB9F Tx 3 2 Rx Rx 2 3 Tx GNOD 5 5 GND DTR 4 4 DTR DSR 6 6 DSR RTS 7 7 RTS CTS 8 8 CTS Figure 173 Cable pinouts FCWnx system to Pelco CM9760 DT DB25F to DB9F FCWnx System Pelco Digi Board CM9760 DT Box OB25F DB9F Tx 2 2 Rx Rx 3 3 Tx GND 7 5 GND RTS 4 4 OTR OTS 5 6 DSR OSR 6 7 RTS DCD 8 8 CTS OTR 20 Installation Pelco This interface program has a separate install utility in the FCWnx directory of the client computer or in the Client directory of the server computer The FCWnx Pelco program can be installed at the same time the FCWnx system is installed or any time thereafter Note Refer to your Pelco manual for DIP switch settings They should be set to the default settings Appendix C CCTV Interfaces To install FCWnx Pelco 1 You must be logged in to the FCWnx computer with administrator privileges If not log out and log on again Note The client on which you are installing FCWnx must be able to communicate on the network with the License Domain Controller 2 Click Start then Run 3 From the Run window click Browse 4 In the Look in field either select the hard drive on which FCWnx is loaded o NON 11 12 13 334 such as C Then navigate to the directory where FCWnx is installed The default is Program Files GE FCWnx Select the CCTVInstall exe Click Open In the Run window click OK Provide the appropriate answer
105. TV alarm you want to change The alarm information now displays 4 Make the desired changes 5 Click Save To delete CCTV alarms within FCWnx 1 From the FCWnx Application Group pane select Gateways amp Interfaces then CCTV Interface 2 Click Search 3 In the Search Result window locate and then select the CCTV alarm you want to delete 4 Click Delete 5 You are prompted to verify your decision to delete Click Yes to delete or No to keep the record Burle Allegiant system The FCWnx Burle Allegiant interface supports the Burle Allegiant controllers TC8500 through TC8901 A serial COM port is the only additional hardware requirement for FCWnx It is used to communicate with the Burle Allegiant controller A separate COM port can also be configured to report Video Loss detection which is reported using the alarm monitor as a Video Loss alarm when one or more cameras lose its video signal A separate video loss alarm is generated for each camera 318 FCWnx 7 7 Global Edition Installation Manual The FCWnx Burle Allegiant interface provides the capability to automatically control Burle Allegiant CCTV cameras and to monitor remotely when FCWnx alarms change state To be able to monitor the alarms the desired FCWnx alarms must be linked or mapped to the appropriate CCTV cameras set up in Burle Allegiant When FCWnx receives the mapped alarm FCWnx sends a message to the Burle Allegiant system to turn on the l
106. Target page opens with the correct path to the folder target populated as shown in Figure 137 Click OK Figure 137 Add Folder Target Ci x Path to folder target GLOBAL32BIT Firmware Browse Example Server Shared Folder Folder o coa 5 You are returned to the New Folder page with all fields populated as shown in Figure 138 Click OK to add the new folder Figure 138 New folder added New Folder E x Name Fimware Preview of namespace E LOBAL32BIT Namespace 1 Fimware Folder targets NGLOBAL32BIT Fimweare For more information about namespace folders see DFS Management OK Cancel 4a Help 6 You are returned to the DFS Management page with the new folder listed under your Namespace Right click on the new folder and then click Add Folder Target as shown in Figure 139 FCWnx 7 7 Global Edition Installation Manual 217 Chapter 5 Configuring Global Edition for file replication Figure 139 Add new folder target fi DFS Management File Action View Window Help A os DFS Management Res Namespaces disneyworld com publicbuilding E gig GLOBAL32BIT Wamespace1 amp Designs EA Externals Type Path Site Referral Status a ae GLOBAL32BIT Firmware Default First Site Name Enabled a global Rename Folder 3 sE Move Folder Replicate Folder View gt
107. Two alarms can be generated from the Burle Allegiant CCTV system e Loss of COMM Alarm e Video Loss Alarm Loss of COMM Alarm This alarm signifies that the interface program is no longer able to communicate with the Allegiant controller Video Loss Alarm This alarm is reported only if you selected the optional video loss port during the installation of the FCWnx Burle Allegiant software A separate alarm is generated for each camera that is configured on the Burle system The first alarm is set up for you However the Video Loss alarm requires that a special command be executed on the Burle Allegiant system to report this alarm Refer to the Burle Allegiant documentation for more information Alarms from FCWnx The FCWnx Burle Allegiant interface allows FCWnx alarms to trigger CCTV cameras monitors to turn on or off on the Burle Allegiant system Before this can happen FCWnx needs to be notified as to which FCWnx alarms are to be the triggers and which messages need to be sent to the Allegiant system to trigger cameras monitors To configure correctly follow the steps below Each step is explained in more detail in the sections that follow 1 Add change or delete the desired CCTV alarms Adding changing or deleting CCTV alarms on page 324 2 Map FCWnx alarms to CCTV alarms See Mapping FCWnx alarms to CCTV alarms on page 337 Appendix C CCTV Interfaces Adding changing or deleting CCTV alarms CCTV
108. Wnx 7 7 Setup installing Global Edtion If you purchased an FCwnx Global Edition license select Yes Select No for any other type of FCWnx license 3 The Custom Configuration window opens for you to choose which FCWnx features to configure on this computer as shown in Figure 22 FCWnx 7 7 Global Edition Installation Manual 49 Chapter 3 Installing Facility Commander Wnx Global configuration Figure 22 FCWnx Global Custom configuration 50 i Facility Commander Wnx 7 7 Setup SSS 5 x FCVvnx Global Custom Configuration oS Choose the appropriate components for a custom Global Edition installation AMA IV Database Serves _ _______ _ Choosing this option will install the FCWnx database components Please select which type of server Global Only one of these per FCWnx Global Edition installation C Regional There can be several of these for an FCWnx Global Edition installation IV File Server Choosing this option will install the FCWnx File Server components IV FCWnx Client Application Choosing this option vall install the FOWnx Client Application Wise Installation Wizard Select one or more of the component options pertaining to the system you are installing Note Some components require that a prerequisite component be installed at another computer before you begin e Database server This option is used to store the Facility Commander Wnx databases An additio
109. Wnx Online Help for addition information about the Integrity utility Click OK The dialog box closes If you receive a message to restart at this time click Yes to restart log on and continue 8 An FCWnx License Setup window opens You cannot license at this time Click Cancel to exit License Setup 9 Continue with configuration of the file server on a second Windows 2003 or 2008 Standard server computer Note Be sure to complete all instructions for the scenario you are installing FCWnx 7 7 Global Edition Installation Manual 179 Chapter 4 Install Global Edition Regional configuration File server on second computer Now you must select and install only the file server component on a separate Windows 2003 or 2008 Standard server computer To install required components 1 Verify that the computer you are configuring meets minimum requirements 2 Insert the FCWnx installation disc into the CD DVD drive When prompted click Run autorun exe If the disc does not launch you must manually start the software Using Windows Explorer navigate to the FCWnx Installation disc and then double click autorun exe 3 The Facility Commander Wnx Main Menu opens Click Install FCWnx v7 7 4 The Facility Commander Wnx introduction page opens Click Install A series of windows may display as the listed components automatically install if not already there These components may cause the system to restart when a new version is
110. a Subscriber without a request from the Subscriber Changes can also be pushed to Subscribers on a scheduled basis FCWnx 7 7 Global Edition Installation Manual 43 Chapter 3 Installing Facility Commander Wnx Global configuration Element Description Regional database server Snapshot agent Subscriber Subscription Transactional replication The machine or machines where the Subscriber Database resides Regional database servers act as client database servers They have the ability to subscribe to publications located on the Global server These Regional servers can operate independently of the Global server for a period of time as necessary Subscriptions are pushed to each Regional server by the Global server This means that the Regional servers do not need to worry about requesting updated data from the Global server updates are periodically supplied to Regional servers according to a set schedule The Snapshot Agent is used with all types of replication It prepares schema and initial data files of published tables and stored procedures stores the snapshot files and inserts information about initial synchronization in the distribution database The Snapshot Agent typically runs under SQL Server Agent at the Distributor There is one Snapshot Agent per publication Subscribers are servers that receive replicated data Subscribers subscribe to publications not to individual articles within a publication and the
111. ach component are updated and identified Facility Commander Wnx installation begins and the Welcome window opens Continue with Facility Commander Wnx software installation begins on page 77 Facility Commander Wnx software installation begins Note A Cancel button displays on every FCWnx installation window If you click Cancel at any time during the installation the FCWnx installation process stops but all Windows components that have been installed must be manually removed To install the file server on the second computer 1 The Facility Commander Wnx Welcome window opens Click Next 2 When the License Agreement window opens select accept the license agreement and click Next FCWnx 7 7 Global Edition Installation Manual 101 Chapter 3 Installing Facility Commander Wnx Global configuration 3 Select the type of installation as Custom and click Next The Custom Configuration window opens as shown in Figure 56 Select File Server Figure 56 FCWnx Global custom configuration file server Facility Commander Wnx 7 7 Setup Cae 5 x FCVvnx Global Custom Configuration O Choose the appropriate components for a custom Global Edition installation lt lt a6 Choosing this option will install the FCWnx database components Please select which type of server Global Only one of these per FCWnx Global Edition installation C Regional There can be several of these for
112. ain user name and password account This account must have administrative privileges to that particular computer We suggest that you use the identical domain account at each computer used in the UTC Fire amp Security system FCWnx 7 7 Global Edition Installation Manual Chapter 3 Installing Facility Commander Wnx Global configuration Figure 36 Logon account for SQL server services te Facility Commander Wnx 7 7 Setup Logon Account for SOL Server Services Enter the domain user account to be used by Microsoft SQL Server for replication Global Edition uses Microsoft SQL Server Replication technology Replication requires that SQL Server Services are running using a domain uset account that has administrator privileges on both the local machine and also on the other FOWnx database servers that are part of the Global Edition installation The domain and user name should be entered with the following format Domain Use N ame For example SPDomain Secure Domain User Name Password Wise Installation Wizard 4 Enter the user domain and username in the format Domain Username or click Browse to navigate the Windows network and select Enter the domain user password in the Password field Click Next to display the Select Credential Aliasing Option window This feature allows you to assign a credential number that represents the encoded credential number This provides added security in that the encoded numb
113. al Edition Regional configuration Figure 85 Fewnx Global Custom configuration Regional database server and FCWnx client application te Facility Commander Wnx 7 7 Setup FCvvnx Global Custom Configuration O Choose the appropriate components for a custom Global Edition installation 7 Database Server Choosing this option will install the FCWnx database components Please select which type of server C Global Only one of these per FC Wnx Global Edition installation Regional There can be several of these for an FCWnx Global Edition installation Tl File Server Choosing this option will install the FCwnx File Server components IV FCWnx Client Application Choosing this option vall install the FCW nx Client Application Wise Installation Wizard e He ces 2 Click Next The Global Database and FileServer Paths window opens as shown in At the Database and FileServer Paths window the Database Server Name displays as read only It is unavailable for entry If the displayed Global Database Server Name is not appropriate select the appropriate Name from the drop down list If the File Server Name displays accept the entry as listed or click Browse to navigate to another computer that may serve as File Server for your system and then select that computer name to display in this dialog box Note You must install the File Server on the selected file server in your Facility Commander Wnx syste
114. al configuration Step Description The Merge Agent is started at the Global database server This agent on its initial creation applies the database snapshot taken by the Snapshot Agent to the Regional database A schedule is updated to operate every day every one minute and set to run As records are added deleted or updated on Regional Servers or the Global database server the changes are replicated to all database Subscribers A new history transactional publication is created on the Regional database server The name of the publication will be similar to the following SecurePerfectHistory SPHistoryPublication A subscription to this publication is created on the Global database server The name of this subscription is Global servername SPSQL SecurePerfectHistory Each Region s history is replicated to the Global database server but it does not redistribute Regional data to another Region History data is a one way replication A new push subscription is created on the Region a snapshot is started and the Transactional Agent is run Note For each history publication on the Regional server there is a corresponding subscription on the Global server while the SecurePerfect database publication has multiple subscribers 5 Remove the Facility Commander Wnx installation disc and continue with instructions to install the file server and FCWnx client application on a second Windows 2003 or 2008 Standard server co
115. all 3 On the Exceptions tab of the Windows Firewall window make sure that the File and Printer Sharing check box is checked and then click OK 14 FCWnx 7 7 Global Edition Installation Manual Chapter 2 Windows Server 2003 2008 Standard and Enterprise Edition Server setup Windows Server 2008 Firewall exceptions list If the firewall is selected ON the following must be enabled in the firewall exceptions list e File and printer sharing e Network discovery e Workgroup only remote administration To enable firewall exceptions selections 1 Click Start and then click Control Panel 2 On the control panel double click Windows Firewall 3 On the Exceptions tab of the Windows Firewall window make sure that the following check boxes are checked and then click OK e File and Printer Sharing e Network discovery e Workgroup only remote administration Adding the computer to a domain The Global and Regional computers must be part of a domain Since network configuration varies from company to company see your network administrator for assistance To add the server to a domain 1 Click Start and then click Control Panel 2 On the control panel double click System 3 Under Computer name domain and workgroup settings click Change settings The System Properties page opens 4 On the Computer Name tab click Change The Computer Name Domain Changes page opens 5 Under Member of click the Domain radio bu
116. allation Manual 73 Chapter 3 Installing Facility Commander Wnx Global configuration Figure 38 Create Database Global database server 3 74 amp Create Convert Database el BS FCWhnx 7 7 Database Collect login information Q To begin the database create convert process please supply the SQL Server SQL 2008 Express administrators username and password in the following text box es Database Server Instance Name Click Next The Create Database Initialize the Database Creation window opens as shown in Figure 39 Each Facility Commander Wnx database consists of data files and transaction logs You have an option to place those components in different physical locations You may consider this if your IT Department has certain policies regarding database installation Consult with your IT Department for assistance Data File directory The Data File Directory field displays the default directory Accept the default as displayed or click the Browse button and browse to any folder location where data files will be stored Note If you are installing in a Cluster configuration the Distributor installs to the same path as the Cluster Data File directory Log File directory The Log File Directory field displays the default directory Accept the default or click the Browse button and browse to the folder location where database log files will be stored Note This refers to the database logs this does NOT refer
117. an FCWnx Global Edition installation IV File Server Choosing this option will install the FCWnx File Server components IT FCWnx Client Application Choosing this option vall install the FCWnx Client Application Wise Installation Wizard 4 Click Next The Change the Secure password window opens 5 The Facility Commander Wnx installation creates a new Windows User ID called secure By default the password is SecurityMaster08 case sensitive If your Windows network has security policies that enforce rules for password creation you may need to change the secure user password If you are unsure ask your system administrator Select one of the following e Use Default Password e Change Password If you select this option enter your new password and then enter a second time 6 Click Next The Ready to Install the Application window opens 7 The default Destination Folder is indicated You may want to install to another location Click Browse to navigate to the program folder of your choice for placement of Facility Commander Wnx files 8 Click Next to continue Facility Commander Wnx copies system files and updates the system configuration This may take a few minutes 102 FCWnx 7 7 Global Edition Installation Manual Chapter 3 Installing Facility Commander Wnx Global configuration 9 When the Facility Commander Wnx has been successfully installed window opens click Finish 10 Remove the Facility Comm
118. ander Wnx Installation disc from the CD DVD drive 11 Now install only the FCWnx client application on a third computer FCWnx client application on third computer Windows XP Professional Windows Vista or Windows 7 operating system Note Prerequisite Database server installation and file server installation already complete Continue with instructions as listed in Chapter 8 Installing Facility Commander Wnx Software on additional clients on page 249 Follow the instructions for custom installations Windows 2003 or Windows 2008 Server operating system Note Prerequisite Database server installation and file server installation already complete To install required components 1 Verify that the computer you are configuring meets minimum requirements 2 If not already done install the Windows 2003 or Windows 2008 operating system but do not install Microsoft SQL 3 You must be logged in as administrator user to the domain If not log off and log back on as a user with administrator permissions 4 Insert the Facility Commander Wnx installation disc into the CD DVD drive 5 When the AutoPlay window opens click Run SETUP EXE 6 The Facility Commander Wnx introduction page opens Click Install A series of windows may display as the listed components automatically install if not already there These components may cause the system to restart when a new version is installed If your computer restarts log on as Adminis
119. another location Click Browse to navigate to the program folder of your choice for placement of Facility Commander Wnx files Click Next to continue Facility Commander Wnx copies system files updates the system configuration and displays the Facility Commander Wnx icon on your desktop This may take a few minutes 11 When the Facility Commander Wnx has been successfully installed window opens click Finish FCWnx 7 7 Global Edition Installation Manual 149 Chapter 4 Install Global Edition Regional configuration 12 Continue with When Regional custom configurations are complete Proceed to Licensing your Facility Commander Wnx system below if you have not already licensed Licensing your Facility Commander Wnx system on page 187 Database server and FCWnx client application configuration Components Computer 1 Computer 2 Computer 3 Database server v File server v FCWnx client application v Note This configuration has the database server and the FCWnx client application installed on Computer 1 while file server is installed on Computer 2 Database server and FCWnx client application on first computer To install the database server and FCWnx client application on the first computer 1 On the FCWnx Global Custom Configuration window select Database Server Regional and FCWnx Client Application as shown in Figure 85 150 FCWnx 7 7 Global Edition Installation Manual Chapter 4 Install Glob
120. anual 77 Chapter 3 Installing Facility Commander Wnx Global configuration 3 Select the type of installation as Custom and click Next The Custom Configuration window opens as shown in Figure 40 Select File Server Figure 40 FCWnx Global custom configuration file server Facility Commander Wnx 7 7 Setup Cae 5 x FCVvnx Global Custom Configuration O Choose the appropriate components for a custom Global Edition installation lt lt a6 Choosing this option will install the FCWnx database components Please select which type of server Global Only one of these per FCWnx Global Edition installation C Regional There can be several of these for an FCWnx Global Edition installation IV File Server Choosing this option will install the FCWnx File Server components IT FCWnx Client Application Choosing this option vall install the FCWnx Client Application Wise Installation Wizard 4 Click Next The Change the Secure password window opens 5 The Facility Commander Wnx installation creates a new Windows User ID called secure By default the password is SecurityMaster08 case sensitive If your Windows network has security policies that enforce rules for password creation you may need to change the secure user password If you are unsure ask your system administrator Select one of the following e Use Default Password e Change Password If you select this
121. are The minimum hardware requirements for server and client computers are listed below Server The following are minimum hardware requirements for server computers e P42 GHz e 2GBRAM e CD DVD drive e 10 100 Mb network card e 1024 by 768 resolution 16 bit color display e 10 GB available hard drive space Hard drive space will vary depending on your system environment If you elect to partition your hard drive verify that sufficient space remains in your system drive for your program files to load properly The following items are recommended e Approved modems if using dial up controllers e Ability for remote Internet access support Client The following are minimum hardware requirements for client computers e P42 GHz e 2GBRAM e CD DVD drive e 10 100 Mb network card e 1024 by 768 resolution 16 bit color display 2 FCWnx 7 7 Global Edition Installation Manual Chapter 1 Introduction to Facility Commander Wnx e 1 GB available hard drive space Hard drive space will vary depending on your system environment If you elect to partition your hard drive verify that sufficient space remains in your system drive for your program files to load properly e If using Imaging an image capture device such as a USB or USB2 0 camera USB cameras are available from UTC Fire amp Security or for a list of approved cameras printers and signature pads refer to ImageWare s web site http www iwsinc com Note If using
122. are occasions when installing Facility Commander from a DVD drive the installation will stall for approximately 10 to 20 minutes from the time you click Install to the time when the Welcome to Facility Commander Wnx 7 7 Installation Wizard page opens If this occurs it is most likely caused by your anti virus software If you have anti virus software running you must configure it so that the DVD drive is not scanned Refer to the documentation that came with your anti virus software for details FCWnx 7 7 Global Edition Installation Manual Chapter 4 Install Global Edition Regional configuration 5 The Facility Commander Wnx installation processes updates on your system When the latest versions of each component are updated and identified Facility Commander Wnx installation begins and the Welcome to the Facility Commander Wnx 7 7 Installation Wizard window opens Continue with Facility Commander Wnx software installation begins on page 47 Facility Commander Wnx software installation begins Note A Cancel button displays on every FCWnx installation window If you click Cancel at any time during the installation the FCWnx installation process stops but all Windows components that have been installed must be manually removed To install the Facility Commander Wnx application 1 The Facility Commander Wnx Welcome window opens Click Next The License Agreement window opens 2 Select accept the license agreement and cli
123. ase Engine and SQL Server Reporting Services Enter the following information and then click OK e Account Name Enter Administrator or the domain account name e Password Enter the administrator password for this operating system Startup Type Select Automatic for SQL Server Agent SQL Server Database Engine and SQL Server Browser Click Next 32 FCWnx 7 7 Global Edition Installation Manual Chapter 2 Windows Server 2003 2008 Standard and Enterprise Edition Server setup Figure 15 Server configuration A Server Configuration Specify the configuration Setup Support Rules Service Accounts Collation Feature Selection Instance Configuration Microsoft recommends that you use a separate account for each SQL Server service Disk Space Requirements Service Account Name Password Startup Type Server Configuration SOL Server Agent Administrator sesceeccees Database Engine Configuration SQL Server Database Engine Administrator i eeseeseeees Automatic x Error and Usage Reporting Installation Rules Ready to Install Use the same account for all SQL Server services Installation Progress Complete These services will be configured automatically where possible to use alow privilege account On some older Windows versions the user will need to specify a low privilege account For more information click Help Service Account Name Password Startup Type SQL Full text Filter Daemon Launcher
124. at the Facility Commander Wnx Server and Client system use the same network properties Refer to Setting the network properties on page 243 for more information or consult with your network administrator Adding the computer to an existing domain The client computers must be part of a domain Since network configuration varies from company to company see your network administrator for assistance To add the client computer to a domain 1 Click Start and then click Control Panel 2 On the control panel double click System 3 Under Computer name domain and workgroup settings click Change settings The System Properties page opens 4 On the Computer Name tab click Change The Computer Name Domain Changes page opens 5 Under Member of click the Domain radio button Enter the Domain server name and then click OK Note A valid domain administrator userid and password is required to add the computer to the domain 6 Restart the server FCWnx 7 7 Global Edition Installation Manual 241 Chapter 7 Windows 7 Vista and XP Professional system setup Installing the operating system The Facility Commander Wnx client computer must be running Windows 7 Windows Vista or Windows XP Professional with applicable Service Pack If the operating system is not already installed on your computer you will need to install it now WARNING The computer must not be configured for Sleep Mode or Hibernate Mode All Facility Commande
125. at the alarm is now reset and responded to and the appropriate camera turns off Setup overview To perform a successful configuration follow these steps 1 Setup the FCWnx system and the American Dynamics system or verify the setup if this is an existing system Figure 162 on page 314 provides a basic example of the hardware setup See Software requirements on page 312 and Hardware requirements on page 314 for more information 2 Install the FCWnx American Dynamics software on the desired FCWnx computer See Installation American Dynamics on page 315 3 Add CCTV alarms and then link or map the desired FCWnx alarms to the appropriate CCTV cameras set up in American Dynamics See Configuring alarms on page 316 and Monitoring on page 337 4 Once the FCWnx and American Dynamics systems are set up and configured operation of the CCTV control feature is a hands free procedure Appendix C CCTV Interfaces Figure 162 Overview of the FCWnx and American Dynamics interface 5301170018 Hardware requirements For the American Dynamics system For the American Dynamics system AD 2150 controller provided by American Dynamics e CCTV cameras and monitors e Cable to connect the FCWnx system and the American Dynamics switches 314 FCWnx 7 7 Global Edition Installation Manual Figure 163 Cable pinouts terminal block to DB25F and terminal block to DB9F RX PIN 4 TXPINS f PIN
126. atabase View Integrity Report cok e gt oee 4 Click Create Database The database creation begins and a progress bar is displayed This may take a few minutes Caution If a database already exists a warning message will display stating that you are about to overwrite your existing database with an empty default database Order of events Regional database server database creation For information only this is the order of events taking place during the Regional database server database creation No action is required on the part of the user Table 17 Order of Events Regional database server database creation Step Description The Regional database server database is created SecurePerfect 1 SecurePerfectHistory and SecurePerfectArchive The Regional database server contacts the SecurePerfectDistributor and Publisher on the Global database server The Regional database is added to the Subscriber s list at the Publisher and a new push subscription is created The Snapshot Agent is started at the Global Database server computer When the 4 agent completes the snapshot of the Global database the snapshot is applied to the Regional database server database FCWnx 7 7 Global Edition Installation Manual 157 Chapter 4 Install Global Edition Regional configuration Step Description The Merge Agent is started at the Global database server This agent on its initial creation appli
127. atabase server databases are created SecurePerfect SecurePerfectHistory and SecurePerfectArchive The SecurePerfectDistributor database is installed and enabled The Global database server is configured for publishing The Publisher is identified by the Global database instance name In this installation scenario there is only one Publisher on the Global database instance Refer to Figure 19 on page 42 The Facility Commander Wnx Merge Publication is defined To define a publication the database to be replicated is selected Within that publication articles are defined The articles are representative of the tables contained within the database FCWnx 7 7 Global Edition Installation Manual Chapter 3 Installing Facility Commander Wnx Global configuration After the Publication is defined the initial Snapshot Agent is started This Agent will create an image of the database at that moment in time Subscribers will utilize this snapshot later The SecurePerfectGlobalHistory database is created This database is only present in the Global database server of a Global Edition installation The following history tables are contained within AlarmHistoryTable BadgeHistoryTable DlHistory DOHistory DVMRHistory GuardTourHistory OperatorHistoryTable SecureAreaHistory ZoneHistoryTable Amessage opens FCWnx Database successfully created Note A log file is created when the Create Database program is run The log file called
128. atabase server on the first computer 1 On the FCWnx Global Custom Configuration window select Database Server and Global as shown in Figure 50 92 FCWnx 7 7 Global Edition Installation Manual Chapter 3 Installing Facility Commander Wnx Global configuration Figure 50 FCWnx Global Custom configuration Database server re Facility Commander Wnx 7 7 Setup FCVvnx Global Custom Configuration aS Choose the appropriate components for a custom Global Edition installation 1 IV Database Server Choosing this option will install the FCWnx database components Please select which type of server Global Only one of these per FCWnx Global Edition installation C Regional There can be several of these for an FCWnx Global Edition installation Choosing this option will install the FCwnx File Server components T FCWnx Client Application Choosing this option will install the FC Winx Client Application Wise Installation Wizard Coresi 2 Click Next The Database and FileServer Paths window opens as shown in Figure 51 At the Database and File Server Paths window the Global Database Server Name and Database Server Name display as read only They are unavailable for entry Enter the computer name or click Browse to navigate to the File server computer for your system and then select the computer to display the name in this field Note You must install the File Server component on the selected file server
129. ation v Note This configuration has all components installed on Computer 1 Although these are the same components as Typical you chose Custom to use credential aliasing or change the secure password To install the database file server and FCWnx client application configuration 1 On the FCWnx Global Custom Configuration window select Database Server Regional File Server and FCWnx Client Application See Figure 69 Figure 69 FCWnx Global custom configuration all components selected re Facility Commander Wnx 7 7 Setup FCWnx Global Custom Configuration oS Choose the appropriate components for a custom Global Edition installation IV Database Server Choosing this option will install the FO Wnx database components Please select which type of server C Global Only one of these per FCWnx Global Edition installation Regional There can be several of these for an FCWnx Global Edition installati IV File Server Choosing this option will install the FCwnx File Server components IV FCWnx Client Application Choosing this option will install the FCWnx Client Application Wise Installation Wizard Bek Nen cea 2 Click Next The Global Database and FileServer Paths window opens as shown in Figure 77 130 FCWnx 7 7 Global Edition Installation Manual Chapter 4 Install Global Edition Regional configuration Select a Global Database Server Name from the drop down list of Servers in this
130. ayed or click the Browse button and browse to any folder location where data files will be stored Note If you are installing in a Cluster configuration the Distributor installs to the same path as the Cluster Data File Directory e Log File Directory The Log File Directory field displays the default directory Accept the default or click the Browse button and browse to the folder location where database log files will be stored Note This refers to the database logs this does NOT refer to the Facility Commander Wnx logs FCWnx 7 7 Global Edition Installation Manual 85 Chapter 3 Installing Facility Commander Wnx Global configuration Figure 46 Create Database Initialize the database creation 5 Create Database FCWhnx 7 7 Database Initialize the database creation Q View Error Log m Database Directory EE oe a TMM View Integrity Report cto __ oee Click Create Database The database creation begins and a progress bar is displayed This may take a few minutes Caution If a database already exists a warning message will display stating that you are about to overwrite your existing database with an empty default database For information only this is the order of events taking place during the Global Database creation No action is required on the part of the user Table 10 Order of Events Global database server database creation Step Description 1 86 The Global d
131. base creation begins and a progress bar is displayed This may take a few minutes Caution If a database already exists a warning message will display stating that you are about to overwrite your existing database with an empty default database WARNING If a database already exists a warning message will display stating that you are about to overwrite your existing database with an empty default database Order of events Regional database server database creation For information only this is the order of events taking place during the Regional database server database creation No action is required on the part of the user FCWnx 7 7 Global Edition Installation Manual 143 Chapter 4 Install Global Edition Regional configuration Table 16 Order of Events Regional database server database creation Step Description The Regional database server database is created SecurePerfect f SecurePerfectHistory and SecurePerfectArchive The Regional database server contacts the SecurePerfectDistributor and Publisher on the Global database server The Regional database is added to the Subscriber s list at the Publisher and a new push subscription is created The Snapshot Agent is started at the Global Database server computer When the 4 agent completes the snapshot of the Global database the snapshot is applied to the Regional database server database The Merge Agent is started at the Global database server This
132. ce Provides web service API for u Local System Sh FCWnnxWCF Service Provides WCF API for use by F Local System lt Extended A Standard To start the FCWnx services 1 Access the Services form 2 Right click FCWnx WebService and select Start 3 All other services are started To stop the Facility Commander Wnx services 1 Shut down all client applications to ensure that any work in progress is saved 2 Access the Services form 3 Right click FCWnx Diagnostics and select Stop A message displays informing you that the other services also stop 4 Click Yes All other services shut down and lastly Diagnostics shuts down To verify or troubleshoot the Facility Commander Wnx services problems look at your log files To set the FCWnx API Service FCWnx API Service is used when an external system is sending or receiving transactions by way of Application Program Interface to Facility Commander Wnx 268 FCWnx 7 7 Global Edition Installation Manual Chapter 9 Logging on and configuring Facility Commander Wnx Starting Facility Commander Wnx The Facility Commander Wnx menu has the following commands Diagnostic Viewer Refer to the document Diagnostics and Troubleshooting on the Documentation disc shipped with your Facility Commander Wnx system in PDF format or Help System for details of this option Facility Commander Wnx Select and click this option to open the Facility Commander Wn
133. censing Facility Commander The Licensing program is used to enter the license key for Facility Commander Wnx The license key controls the following Note If you purchased this system from UTC Fire amp Security the license key is entered for you Number of client licenses You can install Facility Commander Wnx on any number of computers The license controls the number of concurrent clients connected to the server computer Number of Standard Photo Imaging licenses Number of Enhanced Photo Imaging licenses You can install Imaging on any number of computers The license controls the number of Imaging stations active at the same time Number of readers Number of cameras Number of API connections Thin Client enabling Expiration date of the license Client Redundancy enabling Visitor enabling Report Commander License Guard Tours enabling micro controllers only Graphics enabling Types of controllers Deployment parameters DVR types supported this list is enabled if applicable to your system OH Receiver interface A summary of this information can also be viewed by selecting About from the application help menu 226 FCWnx 7 7 Global Edition Installation Manual Chapter 6 License and Set Security Settings for your FCWnx System Generating a registration key To obtain a license key contact UTC Fire amp Security Customer Support as follows Have the barcode from the software box and machine seed key a
134. changes 5 Click Save 324 FCWnx 7 7 Global Edition Installation Manual To delete CCTV alarms within FCWnx 1 From the FCWnx Application Group pane select Gateways amp Interfaces then CCTV Interface 2 Click Search 3 In the Search Result window locate the CCTV alarm you want to delete then select it 4 Click Delete 5 You are prompted to verify your decision to delete Click Yes to delete or No to keep the record Kalatel system The FCWnx Kalatel interface supports the Kalatel controller KTD 348 The FCWnx Kalatel interface provides the capability to automatically control Kalatel CCTV cameras and to monitor remotely when FCWnx alarms change state To be able to monitor the alarms the desired FCWnx alarms must be linked or mapped to the appropriate CCTV cameras set up in Kalatel When FCWnx receives the mapped alarm FCWnx sends a message to the Kalatel system to turn on the linked CCTV cameras and monitors The Kalatel system then controls the appropriate cameras and monitors No operator intervention is required As an alarm is cleared by the operator from the Alarm Monitor form or when the FCWnx alarm resets the Kalatel system is informed that the alarm is now reset and responded to and the appropriate camera turns off Setup overview To perform a successful configuration follow these steps 1 Set up the FCWnx system and the Kalatel system or verify the setup if this is an existing system Fi
135. ck Next 3 Select Custom in the Select Installation Type window as displayed in Figure 66 You must select Custom in order to install a Facility Commander Wnx Global Edition system You must select Custom in order to do any of the following e Install Global Edition features e Select Credential aliasing e Change the password for the Window logon USERID secure e Selectively install Database Server File Server or FCWnx Client Application These configuration options allow Facility Commander Wnx databases and file shares to be separated from Facility Commander Wnx application code and placed on another computer defined by you Note When installing the Facility Commander Wnx software on the Regional database server you must select the type of installation as Custom and select Yes when asked Is this computer part of an FCWnx Global Edition Installation This enables the window that allows you to enter select your Global database server name FCWnx 7 7 Global Edition Installation Manual 125 Chapter 4 Install Global Edition Regional configuration Figure 66 Select Installation type window Select installation Type Select the desired installation type Typical The most common application features will be installed This option a FE is recommended for most users A Custom amp Use this option to choose which application features you want i O installed and where they
136. click Facility Commander Wnx on the navigation Tree 3 From the main menu select Action New and then Group 4 On the New Object Group window e Enter a Group name such as FOWnx Users e Select the Group scope as Global meaning that this is not local to this computer e Select the Group type as Security Click OK to accept and close this window The new group name displays in the details windowpane on the right Right click the new group name that you just created and select Properties from the shortcut menu to open the FCWnx Users Properties window 7 Select the Members tab 8 Click Add to add new members to the newly created group 9 Add Administrator to the new group FCWnx 7 7 Global Edition Installation Manual 113 Chapter 3 Installing Facility Commander Wnx Global configuration 10 Click OK to close the window To add the new Global group to each computer in the domain that is going to run Facility Commander Wnx 1 Click Start Programs Administrative Tools then Active Directory Users and Computers Expand Users Select and then right click SPAdmin from the list of Groups displayed Select Properties from the shortcut menu Click the Members tab Click Add and add FCWnx Users Click OK Your windowpane should display similar to Figure 62 below On the domain you created a new Global group entitled FCWnx Users You then added Administrators as members of that group Since the gr
137. cluding setup and configuration It also contains information for the operating system once the interface is installed Integrated digital video surveillance configuration and management are detailed in the FCWnx User Guide Software requirements For the CCTV system you must have one of the following For the American Dynamics System None For the Burle Allegiant System Allegiant LTC 8359 00 Master control software e For the Kalatel System None e For the Pelco System None For the FCWnx system e FCWnx CCTV Interface program e FCWnx software 312 FCWnx 7 7 Global Edition Installation Manual American Dynamics system The FCWnx American Dynamics interface supports the American Dynamics controller The FCWnx American Dynamics interface provides the capability to automatically control American Dynamics CCTV cameras and to monitor remotely when FCWnx alarms change state To be able to monitor the alarms the desired FCWnx alarms must be linked or mapped to the appropriate CCTV cameras set up in American Dynamics When FCWnx receives the mapped alarm FCWnx sends a message to the American Dynamics system to turn on the linked CCTV cameras and monitors The American Dynamics system then controls the appropriate cameras and monitors No operator intervention is required As an alarm is cleared by the operator from the FCWnx Alarm Monitor form or when the FCWnx alarm resets the American Dynamics system is informed th
138. ct this option enter your new password and then enter a second time 5 Click Next The Ready to Install the Application window opens FCWnx 7 7 Global Edition Installation Manual 181 Chapter 4 Install Global Edition Regional configuration 6 The default Destination Folder is indicated You may want to install to another location Click Browse to navigate to the program folder of your choice for placement of Facility Commander Wnx files 7 Click Next to continue Facility Commander Wnx copies system files and updates the system configuration This may take a few minutes 8 When the Facility Commander Wnx has been successfully installed window opens click Finish 9 Remove the Facility Commander Wnx Installation disc from the CD DVD drive 10 Now install only the FCWnx client application on a third computer FCWnx client application on third computer Windows XP Professional Windows Vista or Windows 7 operating system Note Prerequisite Database server installation and file server installation already complete Continue with instructions as listed in Chapter 8 Installing Facility Commander Wnx Software on additional clients on page 249 Follow the instructions for custom installations Windows 2003 or Windows 2008 Server operating system Note Prerequisite Database server installation and file server installation already complete To install required components 1 Verify that the computer you are configuring mee
139. ction Installation type Custom Select installation Type Select the desired installation type Typical a Ele m e Custom a zi 0 Wise Installation Wizard The most common application features will be installed This option is recommended for most users Use this option to choose which application features you want installed and where they will be installed Recommended for advanced users 4 The Install FOWnx Client Server window opens This window opens only if this is a domain computer You must be part of a domain to continue 5 Select Yes when asked Is this computer part of an FCWnx Global Edition Installation and click Next The Custom Configuration window opens as shown in Figure 101 On the FCWnx Global Custom Configuration window select File Server and FCWnx Client Application 170 FCWnx 7 7 Global Edition Installation Manual Chapter 4 Install Global Edition Regional configuration Figure 101 FCWnx Global Custom configuration File server and FCWnx client application A Facility Commander Wnx 7 7 Setup FCVnx Global Custom Configuration Choose the appropriate components for a custom Global Edition installation 6 Click Next The Global Databases and FileServer Paths window opens as shown in Figure 102 The Database Server Name field is available and required Select a server name from the drop down list of eligible SQL servers for this installation Th
140. ctions assume an un install of all computers in a Global Edition system Note If you are removing a single Region call Technical Support To uninstall Facility Commander Wnx Global configuration 1 You must be logged in as administrator user to the domain If not log off and log back on as a user with administrator permissions 2 Optional If you choose do a backup of your databases Refer to Chapter 11 Back up your Global Edition on page 281 Complete your backups as instructed 3 To uninstall the Facility Commander Wnx application refer to Uninstalling Facility Commander Wnx on page 289 for further instructions Process in this order e Uninstall Facility Commander Wnx client computers to a Regional database server Uninstall Facility Commander Wnx Regional database servers e Uninstall the Facility Commander Wnx Global database server 4 OPTIONAL Delete Facility Commander Wnx databases at the Global database server 288 FCWnx 7 7 Global Edition Installation Manual Chapter 12 Uninstall Facility Commander Wnx or delete a database Uninstalling Facility Commander Wnx 1 Log on as someone with administrative privileges other than secure such as administrator 2 Click Start Control Panel and then Add Remove Programs 3 From the list of currently installed programs that display select Facility Commander Wnx 7 7 4 Click Remove The Add or Remove Programs window opens asking you to confirm t
141. d FileServer Paths O Global Database Server Name eee Database Server Name z File Server Name alesse aie egree emia Browse Wise Installation Wizard Cores 8 Click Next The Change the Secure password window opens The Facility Commander Wnx installation creates a new Windows User ID called secure By default the password is SecurityMaster08 case sensitive If your Windows network has security policies that enforce rules for password creation you may need to change the secure user password If you are unsure ask your system administrator Select one of the following e Use Default Password e Change Password If you select this option enter your new password and then enter a second time 9 Click Next The Ready to Install the Application window opens The default Destination Folder is indicated You may want to install to another location Click Browse to navigate to the program folder of your choice for placement of Facility Commander Wnx files 10 Click Next to continue Facility Commander Wnx copies system files updates the system configuration and displays the Facility Commander Wnx icon on your desktop This may take a few minutes 11 When the Facility Commander Wnx has been successfully installed window opens click Finish 186 FCWnx 7 7 Global Edition Installation Manual Chapter 4 Install Global Edition Regional configuration When Regional custom configurations are comple
142. d shutting down Logging off of Windows To log off 1 Exit Facility Commander Wnx by selecting Exit from the File menu Enter your password in the Password field of the Exit window and click OK 2 From the Desktop click Start then Shut Down 3 From the Shut Down Windows form select Log off xxxx where xxxx is the user name that was used to log on Click OK 4 This logs off the current user and allows another user to log on Keep in mind that the Facility Commander Wnx services are still running but you will not receive any alarm notifications Note Also see Facility Commander Wnx services overview on page 266 for additional information relating to Facility Commander Wnx services Automatic client shutdown Services will automatically shut down if this option is selected on the Client Form unless you disable Auto Shutdown on the Parameter Form when a client closes the Facility Commander Wnx application and meets all of the following criteria e Does not host any controllers or DVRs e Does not have any API connections e Does not host a Thin Client e ls not a backup client for or have any backup clients of its own e Is nota CCTV client e Does not host a Guard Tour The shutting down of a particular client computer designates that license capacity unused Now that license is available for another computer that can now be designated a Facility Commander Wnx client FCWnx 7 7 Global Edition Installation Man
143. d the Preinstallation checklist section in its entirety To assist in configuration of your Facility Commander Wnx Global configuration Regional platform system review this checklist e Prepare and configure your Global system in this order as detailed in Installation and setup outlines on page 5 e Each server computer must be part of a new or existing domain If you are creating a new domain always consult with the network administrator before adding a domain or adding any computers to an existing network Refer to Adding the computer to an existing domain below e Be prepared to license your software for Global configuration Adding the computer to an existing domain Since the server computer will be part of a new or existing domain you must add the server computers to the network Network configuration varies from company to company see your network administrator for assistance It is important that the Server and Client system use the same network properties Refer to Setting the network properties on page 13 and Setting the network properties on page 243 for more information or consult with your network administrator 122 FCWnx 7 7 Global Edition Installation Manual Chapter 4 Install Global Edition Regional configuration Adding SQL Server and SQLServerAgent services to an existing domain In Windows services the SQL Server SPSQL and SQL Server Agent services must use a domain account The SQL
144. database with an empty default database Order of events Global database server database creation For information only this is the order of events taking place during the Global Database creation No action is required on the part of the user Table 11 Order of Events Global database server database creation Step Description 1 The Global database server databases are created SecurePerfect SecurePerfectHistory and SecurePerfectArchive 2 The SecurePerfectDistributor database is installed and enabled 3 The Global database server is configured for publishing The Publisher is identified by the Global database instance name In this installation scenario there is only one Publisher on the Global database instance Refer to Figure 19 on page 42 4 The Facility Commander Wnx Merge Publication is defined To define a publication the database to be replicated is selected Within that publication articles are defined The articles are representative of the tables contained within the database FCWnx 7 7 Global Edition Installation Manual 99 Chapter 3 Installing Facility Commander Wnx Global configuration 5 After the Publication is defined the initial Snapshot Agent is started This Agent will create an image of the database at that moment in time Subscribers will utilize this snapshot later 6 The SecurePerfectGlobalHistory database is created This database is only present in the Global database server of a Global Edition i
145. der Wnx icon on your desktop This may take a few minutes 12 When the Facility Commander Wnx has been successfully installed window opens click Finish The FCWnx License Setup window opens 172 FCWnx 7 7 Global Edition Installation Manual Chapter 4 Install Global Edition Regional configuration 13 Proceed to license your system at this time Refer to Licensing your Facility Commander Wnx system on page 187 Each component on a separate computer Components Computer 1 Computer 2 Computer 3 Database server v File server v FCWnx client application v Note This configuration has the database server installed on Computer 1 the file server installed on Computer 2 and the FCWnx client application installed on Computer 3 To install the database server on the first computer 1 On the FCWnx Global Custom Configuration window select Database Server and Regional as shown in Figure 103 Figure 103 FCWnx Global Custom configuration Regional database server re Facility Commander Wnx 7 7 Setup FCVVnx Global Custom Configuration O Choose the appropriate components for a custom Global Edition installation a IV Database Server Choosing this option will install the FCWnx database components Please select which type of server C Global Only one of these per FCWrx Global Edition installation Regional There can be several of these for an FCWnx Global Edition installat I File Server Choosing thi
146. domain The Database Server Name and File Server Name are unavailable for input Figure 70 Global Database and FileServer Paths i Facility Commander Wnx 7 7 Setup os i xi Global Database and FileServer Paths O m Global Database Server Name File Server Name REGIONAL32BIT Wise Installation Wizard 3 Click Next to display the Logon Account for SQL Server Services window as shown in Figure 71 Note Each server used in the Facility Commander Wnx Global Edition system requires the database services to run under a domain user name and password account This account must have administrative privileges to that particular computer We suggest that you use the identical domain account at each computer used in the UTC Fire amp Security system FCWnx 7 7 Global Edition Installation Manual 131 Chapter 4 Install Global Edition Regional configuration Figure 71 Logon account for SQL server services fe Facility Commander Wnx 7 7 Setup Bins ae AE xj Logon Account for SQL Server Services Enter the domain user account to be used by Microsoft SOL Server for replication Enr Global Edition uses Microsoft SQL Server Replication technology Replication requires that SQL Server Services are running using a domain uset account that has administrator privileges on both the local machine and also on the other FOWnx database servers that are part of the Global Edition installation The domain and user name should b
147. e File Server Name is a read only field and is unavailable for selection FCWnx 7 7 Global Edition Installation Manual 171 Chapter 4 Install Global Edition Regional configuration Figure 102 Database server name required Facility Commander Wnx 7 7 Setup ees 5 x Global Database and FileServer Paths O S Global Database Server Name Database Server Name z Wise Installation Wizard _ lt Beck ye f co 7 Click Next to display the Change the Secure password window 8 The Facility Commander Wnx installation creates a new Windows User ID called secure By default the password is SecurityMaster08 case sensitive If your Windows network has security policies that enforce rules for password creation you may need to change the secure user password If you are unsure ask your system administrator Select one of the following on the Change the Secure password window e Use Default Password e Change Password If you select this option enter your new password and then enter a second time 9 Click Next to continue The Ready to Install the Application window opens 10 The default Destination Folder is indicated You may want to install to another location Click Browse to navigate to the program folder of your choice for placement of Facility Commander Wnx files 11 Click Next to continue Facility Commander Wnx copies system files updates the system configuration and displays the Facility Comman
148. e Pelco system or verify the setup if this is an existing system Figure 170 on page 332 provides a basic example of the hardware setup See Hardware requirements on page 332 for more information 2 Install the FCWnx Pelco software on the desired FCWnx computer See Installation Pelco on page 333 3 Add CCTV alarms and then link or map the desired FCWnx alarms to the appropriate CCTV cameras set up in Pelco Configuring alarms on page 335 and Monitoring on page 337 4 Once the FCWnx and Pelco systems are set up and configured operation of the CCTV control feature is a hands free procedure Appendix C CCTV Interfaces Figure 170 Overview of the FCWnx and Pelco interface 530109005A Hardware requirements For the Pelco system e Cable to connect the CM9760 DT box and the controller Refer to Figure 171 below for cable pinout information e CCTV cameras and monitors e CM9760 controller provided by Pelco e CM9760 DT box provided by Pelco e Pelco CCTV equipment Figure 171 Cable pinouts CM9760 DT box to controller DB9F to DB9F Pelco Pelco CM9760 DT Box CM9760 Controller DBOF DBOF Rx 2 3 Tx TX 3 2 Rx GND 5 5 GND For the FCWnx system e FCWnx computer 332 FCWnx 7 7 Global Edition Installation Manual e Refer to Installation Pelco below e Cable to connect the FCWnx system and the Pelco CM9760 DT box Figure 172 Cable pinouts FCWnx to Pelco CM9760 DT to DB9F FCWnx
149. e about to overwrite your existing database with an empty default database Order of events Global database server database creation For information only this is the order of events taking place during the Global Database creation No action is required on the part of the user Table 8 Order of Events Global database server database creation Step Description 1 The Global database server databases are created SecurePerfect SecurePerfectHistory and SecurePerfectArchive 2 The SecurePerfectDistributor database is installed and enabled 3 The Global database server is configured for publishing The Publisher is identified by the Global database instance name In this installation scenario there is only one Publisher on the Global database instance Refer to Figure 19 on page 42 4 The Facility Commander Wnx Merge Publication is defined To define a publication the database to be replicated is selected Within that publication articles are defined The articles are representative of the tables contained within the database FCWnx 7 7 Global Edition Installation Manual 63 Chapter 3 Installing Facility Commander Wnx Global configuration After the Publication is defined the initial Snapshot Agent is started This Agent will create an image of the database at that moment in time Subscribers will utilize this snapshot later The SecurePerfectGlobalHistory database is created This database is only present in the Global databas
150. e computer over the network 250 Pinging the First Time License computer 250 Checking computer accessibility over the network 252 Installing Facility Commander Wnx Windows 7 Windows Vista or Windows XP Professional additional client computer 253 Before you begin 253 Starting the installation 253 Facility Commander Wnx software installation begins 254 Custom installation 255 Licensing the client computer 258 Setting services to automatic startup 258 Items specific to Windows Vista and Windows 7 260 Windows communication foundation HTTP activation 260 Global configuration client installations 260 Logging on to client computer 260 Viewing Imaging status 261 FCWnx 7 7 Global Edition Installation Manual 249 Chapter 8 Installing Facility Commander Wnx Software on additional clients Imaging login setup 261 Client folder structure 263 Client folders 264 What s next 264 Defining additional clients If you have not already done so you must add the client computers to the Facility Commander Wnx database before installing the Facility Commander Wnx software on the additional clients Refer to Adding clients to the database on page 222 Reaching the First Time License computer over the network Verify that you can reach the First Time License computer by computer name before you install Facility Commander Wnx on additional clients e Typical Installation The server computer is the First Time License computer and you can add clie
151. e entered with the following format Domain UsemName For example SPDomain Secure Domain U ser Name Browse Password Wise Installation Wizard 4 Enter the user domain and username in the format Domain Username or click Browse to navigate the Windows network and select Enter the domain user password in the Password field 5 Click Next The Change the Secure password window opens as shown in Figure 72 The Facility Commander Wnx installation creates a new Windows User ID called secure By default the password is SecurityMaster08 case sensitive If your Windows network has security policies that enforce rules for password creation you may need to change the secure user password If you are unsure ask your system administrator Select one of the following on the Change the Secure password window Use Default Password e Change Password Enter your new password and then enter a second time 132 FCWnx 7 7 Global Edition Installation Manual Chapter 4 Install Global Edition Regional configuration Figure 72 Change the Secure password ie Facility Commander Wnx 7 7 Setup Change the Secure password O Change the password for the Windows Logon USERID Secure The FCW installation creates a new Windows USERID called Secure By default the password is SecurityMaster08 If your Windows network has secunty policies that enforce rules for password creation you
152. e existing network Refer to the Microsoft Installation Guide for details of a network card configuration or obtain information at www microsoft com technet For Windows 7 operating systems if you are using multiple network interface cards NICs for FCWnx related use make sure that you choose the same network profile for each NIC When attaching your NIC to a new not previously configured network a popup window opens asking whether this new network is Home Work or Public Make sure you choose the same for both NICs so that when FCWnx is installed and SecurityCnfg is run the profile will have the correct FCWnx ports open 240 FCWnx 7 7 Global Edition Installation Manual Chapter 7 Windows 7 Vista and XP Professional system setup Configure the computer for the network Determining computer type Before you continue consult with the network administrator before adding any computers to an existing network The server computer must be part of a new or existing domain See Adding the computer to a domain below Note Setup will be different depending on which option you choose Decide the configuration type before you continue with the installation Adding the computer to a domain Since your Professional computer will be part of an existing domain you will need to add the computer to the network Since network configuration varies from company to company see your network administrator for assistance It is important th
153. e per FCwnx Global Edition installation C Regional There can be several of these for an FCWnx Global Edition ataia I Fie Server Choosing this option will install the FCwnx File Server components IV FCwnx Client Application emee aeoaea auaa Choosing this option vall install the FCwnx Client Application Wise Installation Wizard Cen FCWnx 7 7 Global Edition Installation Manual 69 Chapter 3 Installing Facility Commander Wnx Global configuration Click Next The Global Database and File Server Paths window opens as shown in Figure 35 below At the Database and File Server Paths window the Global Database Server Name and Database Server Name display as read only They are unavailable for entry If the File Server Name opens accept the entry as listed or click Browse to navigate to another computer that may serve as File Server for your system and then select that computer name to display in this dialog box Note You must install File Server on the selected file server in your Facility Commander Wnx system before attempting to license any Facility Commander Wnx application Figure 35 File server name required 70 i Facility Commander Wnx 7 7 Setup Wise Installation Wizard The Logon Account for SQL Server Services window opens as shown in Figure 36 on page 71 Note Each server used in the Facility Commander Wnx Global Edition system requires the database services to run under a dom
154. e separate computers e If you changed the secure password e If you installed on a Windows Cluster Server Note If you change the default Facility Commander Wnx user password all computers must use the identical Facility Commander Wnx user replacement password 254 FCWnx 7 7 Global Edition Installation Manual Chapter 8 Installing Facility Commander Wnx Software on additional clients Custom installation Caution Custom Installation is recommended for experienced software installers only You must select Custom in order to accomplish the following e Complete the configuration when the Database Server and File Server are on different computers e Change the secure password Note If you change the default Facility Commander Wnx user password all computers must use the identical Facility Commander Wnx replacement user password To select type of installation and continue 1 Select the type of installation as Custom as displayed in Figure 148 Figure 148 Select Custom Installation Type Select installation Type Select the desired installation type Typical The most common application features will be installed This option er zs is recommended for most users 7 a Custom amp Use this option to choose which application features you want z installed and where they will be installed Recommended for p advanced users Wise Installation Wizard 2 Click Next The Installing Global Ed
155. e server of a Global Edition installation The following history tables are contained within AlarmHistoryTable BadgeHistoryTable DlHistory DOHistory DVMRHistory GuardTourHistory OperatorHistoryTable SecureAreaHistory ZoneHistoryTable A message opens FCWnx Database successfully created Note A log file is created when the Create Database program is run The log file called CreateDatabaseLog is found in the Logs folder The Integrity utility runs automatically following a database creation No user interaction is required Refer to your Facility Commander Wnx Online Help for addition information about the Integrity utility 7 Click OK The dialog box closes 10 If you receive a message to restart at this time click Yes to restart log on and continue An FCWnx License Setup window opens Unless otherwise stated in your configuration scenario proceed to Licensing your Facility Commander Wnx system on page 108 Remove the Facility Commander Wnx installation disc and continue with instructions to install FCWnx Client Application FCWnx client application on second computer Windows XP Professional Windows Vista or Windows 7 operating system Note Prerequisite Database server installation and file server installation already complete Continue with instructions as listed in Chapter 8 Installing Facility Commander Wnx Software on additional clients on page 249 Follow the instructions for cu
156. e status will be either Started or blank If it is blank then the service is not running 4 Right click and then select Properties In the Startup type field select Automatic Click Apply and then OK to close the window Repeat steps 3 through 6 for the following services FCWnx Manager FCWnx Media Server FCWnx System Manager FCWnx WebService e FCWnx WCF Service Note FCWnx API Service is used when an external system is sending or receiving transactions by way of an Application Program Interface API to FCWnx When all services are configured close all windows and applications Restart the Facility Commander Wnx server computer FCWnx 7 7 Global Edition Installation Manual 259 Chapter 8 Installing Facility Commander Wnx Software on additional clients Items specific to Windows Vista and Windows 7 Windows communication foundation HTTP activation If the Video Management Console VMC will be running on this computer Windows Communication Foundation HTTP Activation must be enabled To enable Windows Communication Foundation HTTP Activation 1 Click Start Control Panel and then Programs and Features 2 Select Turn Windows features on or off from the Tasks panel on the left 3 Search for Microsoft NET Framework 3 5 and then check the Windows Communication Foundation HTTP Activation check box Global configuration client installations When this additional client is part of a Facility Commander Wnx
157. eandsecurity com Content Preface v Safety terms and symbols v Related documentation v Chapter 1 Introduction to Facility Commander Wnx 1 Recommended minimum requirements 2 Before you begin 4 Installation and setup outlines 5 Chapter 2 Windows Server 2003 2008 Standard and Enterprise Edition Server setup 7 Preinstallation checklist 9 Network card 10 Configuring the computer for the network 10 Installing the operating system 11 Setting up your monitor 12 Setting the network properties 13 Windows firewall 14 Defining user accounts 16 Installing Microsoft SQL Server 17 Microsoft SQL Server 2005 17 Microsoft SQL Server 2008 29 What s next 38 Chapter 3 Installing Facility Commander Wnx Global configuration 39 Benefits of Facility Commander Wnx Global configuration 41 Sample configuration overview 41 Global configuration definitions 43 Preinstallation checklist 44 Installation 46 Database server file server and FCWnx client application configuration 52 Database server and file server configuration 57 Database server and FCWnx client application configuration 69 Database server configuration 79 Each component on a separate computer 92 Licensing your Facility Commander Wnx system 108 Configuring security settings 108 Setting services to automatic startup 109 FCWnx 7 7 Global Edition Installation Manual Server folder structure 110 Facility Commander Wnx user accounts 113 Create FCWnx database utility 115 What s next 12
158. eates a new Windows User ID called secure By default the password is SecurityMaster08 case sensitive If your Windows network has security policies that enforce rules for password creation you may need to change the secure user password If you are unsure ask your system administrator Select one of the following on the Change the Secure password window e Use Default Password e Change Password If you select this option enter your new password and then enter a second time 9 Click Next The Ready to Install the Application window opens 10 Enter the SQL Server password for the SA user This password was created during installation of Microsoft SQL Refer to Installing Microsoft SQL Server on page 17 Note Enter your previously assigned SQL password here If you purchased your Facility Commander Wnx system from UTC Fire amp Security a temporary password of SecurityMaster08 case sensitive was assigned for you 11 The default Destination Folder is indicated You may want to install to another location Click Browse to navigate to the program folder of your choice for placement of Facility Commander Wnx files 12 Click Next to continue A series of Access Control and Security Management windows display as Facility Commander Wnx copies system files updates the system configuration and displays the Facility Commander Wnx icon on your desktop This may take a few minutes 13 When the Facility Commander W
159. ed for a single folder share Follow the procedures below for each additional FCWnx server computer that will act as a file replication share To create a new replica target Right click the Dfs link to display the shortcut menu and select New Target The New Target window opens 1 On the New Target window In the Path to target shared folder field enter the path for an alternate server computer name and shared folder or click Browse to navigate to the appropriate shared folder on the alternate server computer At this point your windows should look similar to Figure 129 Select Add this target to the replication set if not already selected FCWnx 7 7 Global Edition Installation Manual 209 Chapter 5 Configuring Global Edition for file replication Figure 129 Adding a New Replica 3 Click OK You prompted to configure the replication Figure 130 Distributed File System Distributed File System 4 Click OK The Replication Wizard window opens as shown in Figure 131 210 FCWnx 7 7 Global Edition Installation Manual Chapter 5 Configuring Global Edition for file replication Figure 131 Replication Wizard Configure Replication Wizard x You must select one target as the initial master The first time you start replication its contents are replicated to the other targets Targets that are not eligible to join file replication are denoted with a red X Select an initial master
160. el similar to Figure 127 after the first folder Dfs link is created FCWnx 7 7 Global Edition Installation Manual Enter the path or click Browse to navigate to the appropriate share folder on the same computer that has the Replication share configured in Creating Dfs Root on page 201 Leave the default for the field Amount of time clients cache this referral in seconds at 1800 207 Chapter 5 Configuring Global Edition for file replication Figure 127 Distributed File System Snap In with Replication Dfs Root and First Client Dfs Link A Distributed File System Ele Action View Help e gt OH ABO hike Distributed File System Target DFSReferral_ Status E ee A pa Test Video Enabled Video ee ee ee E 5 Now the other file shares can be added as replicas to the main Dfs link Repeat steps 2 and 3 for all shares e Designs e Externals e Firmware e Video When complete your window opens similar to Figure 128 208 FCWnx 7 7 Global Edition Installation Manual Chapter 5 Configuring Global Edition for file replication Figure 128 Distributed File System Snap In with Replication Dfs Root Distributed File System 2 5 xj Ele Action View Help e O88 SAB 2 RMB Distributed File System gel GW boca com Replication ea Test Video my Designs Externals F Firmware Creating a New Replica Target As many replicas targets as necessary can be creat
161. elow Select Global Database Server l 2 The Create Convert Database window opens Figure 45 Create database Global database server amp Create Convert Database FCWnx 7 7 Database Collect login information Q To begin the database create convert process please supply the SQL Server SQL 2008 Express administrators username and password in the following text box es m Database Server instance Name GLOBAL32BIT SPSQL Enter Username ba Enter Password eens 84 FCWnx 7 7 Global Edition Installation Manual 3 Chapter 3 Installing Facility Commander Wnx Global configuration Ignore the sa User Name as displayed The Password field opens your previously assigned and encrypted SQL password If you purchased your Facility Commander Wnx system from UTC Fire amp Security a temporary password of SecurityMaster08 case sensitive was assigned for you Accept the password as displayed Click Next The Create Database Initialize the Database Creation window opens as shown in Figure 46 Each Facility Commander Wnx database consists of data files and transaction logs You have an option to place those components in different physical locations You may consider this if your IT Department has certain policies regarding database installation Consult with your IT Department for assistance e Data File Directory The Data File Directory field displays the default directory Accept the default as displ
162. ens Click Next 8 The Confirm Installation Selections page opens Click Install FCWnx 7 7 Global Edition Installation Manual 35 Chapter 2 Windows Server 2003 2008 Standard and Enterprise Edition Server setup Windows Server 2008 Distributed File System Installation The Distributed File System must be installed on all Global and Regional Servers before File Replication can be configured To install Distributed File Services 1 Click Start Control Panel and then double click Administrative Tools 2 Double click Server Manager The Server Manager window opens 3 On the left pane under Server Manager click Roles A list of installed roles is displayed in the right pane under Roles Summary 4 Click Add Roles The Add Roles Wizzard opens Click Next 5 The Select Server Roles page opens Check the File Services check box and then click Next 6 The File Serices page opens click Next 7 The Select Role Services page opens Check the File Server Distributed File System includes DFS Namespaces and DFS Replication and Services for Network File System check boxes Click Next 8 The Select Namespace Type page opens Click Next 9 The Configure Namespace page opens Click Next 10 The Configure Storage Usage Monitoring page opens Click Next 11 The Confirm Installation Selections page opens Click Install 12 The Installation Results page opens and should indicate the Installation succeeded Click Close Micr
163. ent Preinstallation checklist 122 Adding the computer to an existing domain 122 Adding SQL Server and SQLServerAgent services to an existing domain 123 Before you begin 124 Installation 124 Starting the installation 124 Facility Commander Wnx software installation begins 125 Custom installation Regional database server 126 Custom configuration options 129 Database server file server and FCWnx client application configuration 130 Database server and file server configuration 138 FCWnx client application on second computer 145 Database server and FCWnx client application configuration 150 Database server configuration 161 Each component on a separate computer 173 When Regional custom configurations are complete 187 Licensing your Facility Commander Wnx system 187 Configuring security settings 187 Setting services to automatic startup 188 FCWnx 7 7 Global Edition Installation Manual 121 Chapter 4 Install Global Edition Regional configuration Setting services to automatic startup 188 Server folder structure 190 Facility Commander Wnx user accounts 192 Adding a new Global group to the domain 193 What s next 194 Create FCWnx Database Utility 194 Preinstallation checklist You are now ready to begin configuring your Regional Database server computer Before you begin this chapter you should have completed the instructions in Chapter 3 Installing Facility Commander Wnx Global configuration on page 39 Note Rea
164. eparate computers e The file server stores the Licenselnfo file e The First Time License computer stores the Component Services files Note You must be able to reach the computer s for both sources 2 From the File menu select Login 3 Log on as secure with a password of SecurityMaster08 case sensitive If client computers have Windows XP Professional or Windows Vista installed and if they are on the network you can access the Client Form in the Facility Commander Wnx application and proceed with adding clients to the database To access the Client Form 1 From the Application Group pane select Administration and then Client A new client form is displayed 2 Click Add from the Facility Commander Wnx toolbar 3 Enter data describing your new client Refer to Online Help for details of each individual field Note If a client computer is currently offline or connected to the network by a gateway or hub you may not see that computer You may need to correct network issues with the client computer before proceeding You may also see computers that cannot be clients since they do not use TCP IP protocols 4 Click Save 5 Repeat steps 2 through 4 for all clients 222 FCWnx 7 7 Global Edition Installation Manual Chapter 5 Configuring Global Edition for file replication 6 You can add as many clients as you want However only the licensed maximum number can connect to the server at the same time Refer
165. er Wnx Online Help for addition information about the Integrity utility Click OK The dialog box closes If you receive a message to restart at this time click Yes to restart log on and continue 8 An FCWnx License Setup window opens You cannot license at this time Click Cancel to exit License Setup 9 Continue with configuration of the file server on a second Windows 2003 or 2008 Standard server computer File server on second computer Now you must select and install only the file server component on a separate Windows 2003 or 2008 Standard server computer Note Prerequisite database server and FCWnx client application installation already complete If you do not install the file server at this time you will not be able to license your system To install required components 1 Verify that the computer you are configuring meets minimum requirements 158 FCWnx 7 7 Global Edition Installation Manual 2 Chapter 4 Install Global Edition Regional configuration Insert the FCWnx installation disc into the CD DVD drive When prompted click Run autorun exe If the disc does not launch you must manually start the software Using Windows Explorer navigate to the FCWnx Installation disc and then double click autorun exe 3 The Facility Commander Wnx Main Menu opens Click Install FCWnx v7 7 The Facility Commander Wnx introduction page opens Click Install A series of windows may display as the listed compone
166. er is only displayed to authorized users e Do not use aliases indicates no aliasing will be used e Use aliases automatically provided by FCWnx assigns the credential number for you e Use aliases manually provided by user aliasing allows you to assign the number 7 Choose one aliasing option then click Next The Change the Secure password window opens FCWnx 7 7 Global Edition Installation Manual 71 Chapter 3 Installing Facility Commander Wnx Global configuration 8 The Facility Commander Wnx installation creates a new Windows User ID called secure By default the password is SecurityMaster08 case sensitive If your Windows network has security policies that enforce rules for password creation you may need to change the secure user password If you are unsure ask your system administrator Select one of the following on the Change the Secure password window e Use Default Password e Change Password If you select this option enter your new password and then enter a second time 9 Click Next The Ready to Install the Application window opens 10 The default Destination Folder is indicated You may want to install to another location Click Browse to navigate to the program folder of your choice for placement of Facility Commander Wnx files 11 Click Next to continue Facility Commander Wnx copies system files updates the system configuration and displays the Facility Commander Wnx icon on your desktop
167. ertain policies regarding database installation Consult with your IT Department for assistance e Data File Directory The Data File Directory field displays the default directory Accept the default as displayed or click the Browse button and browse to any folder location where data files will be stored Note If you are installing in a Cluster configuration the Distributor installs to the same path as the Cluster Data File Directory e Log File Directory The Log File Directory field displays the default directory Accept the default or click the Browse button and browse to the folder location where database log files will be stored Note This refers to the database logs this does NOT refer to the Facility Commander Wnx logs FCWnx 7 7 Global Edition Installation Manual Chapter 3 Installing Facility Commander Wnx Global configuration Figure 55 Create Database Initialize the database creation fe create Database T FCWhnx 7 7 Database Initialize the database creation Q View Error Log m Database Directory r area a I TMM GE FCWnx Database m Log File Directory C Program Files GE FCWnx Database at View Integrity Report cok e gt ooe 5 Click Create Database The database creation begins and a progress bar is displayed This may take a few minutes Caution If a database already exists a warning message will display stating that you are about to overwrite your existing
168. erver Configuration C Windows authentication mode Se eee ee Mixed Mode SQL Server authentication and Windows authentication Reporting Services Configuration Error and Usage Reporting Built in SQL Server system administrator accourt Installation Rules Enter password jeeeecsscecescses Ready to Install Confirm password jeeeeecescccscces Installation Progress Complete Specify SQL Server administrators SQL Server administrators have unrestricted access to the Database Engine Add Current user Add Remove Figure 17 Select Users or Groups Select users or crowns T Select this object type lsers Groups or Built in security principals Object Types From this location fWin 6MeaD41V306 Locations Enter the object names to select examples WIN 6M64D41V30B Administrator Check Names sre E 21 The Error and Usage Reporting window opens Click Next 22 The Installation Rules window opens Click Next 23 The Ready to Install window opens Click Install 24 The Installation Progress window opens When the setup process is complete click Next 25 The Complete window opens Click Close 26 We recommend that you restart your computer at this time 34 FCWnx 7 7 Global Edition Installation Manual Chapter 2 Windows Server 2003 2008 Standard and Enterprise Edition Server setup Install SQL 2008 Service Pack 1 Service Pack 1 is required If it is not currently
169. erver must already be snstelled with an instance of SPSQL This option will install the Regional Database Server as iii on a local client A Distributor must be selected from ist below Select Global Database Server l 2 The Create Convert Database window opens as shown in Figure 54 Figure 54 Create database Global database server amp Create Convert Database FCWnx 7 7 Database Collect login information Fe To begin the database create convert process please supply the SQL Server SQL 2008 Express administrators username and password in the following text box es m Database Server instance Name JELOBAL32BIT SPSQL Enter Username ba Enter Password peaa FCWnx 7 7 Global Edition Installation Manual 97 Chapter 3 Installing Facility Commander Wnx Global configuration 3 98 Ignore the sa User Name as displayed The Password field opens your previously assigned and encrypted SQL password If you purchased your Facility Commander Wnx system from UTC Fire amp Security a temporary password of SecurityMaster08 case sensitive was assigned for you Accept the password as displayed Click Next The Create Database Initialize the Database Creation window opens as shown in Figure 55 Each Facility Commander Wnx database consists of data files and transaction logs You have an option to place those components in different physical locations You may consider this if your IT Department has c
170. ervice Account Service accounts define which accounts to log in Usernames Passwordi Bomam 18 An Authentication Mode window opens as shown in Figure 7 FCWnx 7 7 Global Edition Installation Manual 23 Chapter 2 Windows Server 2003 2008 Standard and Enterprise Edition Server setup Figure 7 Authentication Mode i Microsoft SQL Server 2005 Setup E x Authentication Mode The authentication mode specifies the security used when 4 connecting to SQL Server N a Select the authentication mode to use For this installation Windows Authentication Mode Mixed Mode Windows Authentication and SQL Server Authentication Specify the sa logon password below Enter password ire Confirm password ir Help lt Back Cancel 19 Select Mixed Mode and enter the sa password then enter the password again to confirm This password is case sensitive Note We strongly suggest that you assign a unique password of your choice This is the sa user password used later in the installation of your application during creation of the database 20 Click Next A Collation Settings window opens 21 Leave all default settings Do not change any selections on this window Click Next 22 An Error and Usage Report Settings window opens Do not change any options on this page Accept the defaults and click Next 23 When the Ready to Install window opens verify the components selections
171. ervices and connection types used by your applications Disabling unused services and connections heps protect your server by reducing the surface area For default settings see Help Select a component and then configure its services and connections S g SPsau By default SOL Server 2005 Express Evaluation and Developer editions alow local a ij Database Engre client connections only Erterpiise Standard and Workgroup editions also fisten for Servi temote cient connections over TCP IP Use the options below to change the ahh on which SOL Server Estens for incoming chant connections TCP IP is prefered over gt Goes named pipes because it requires fewer ports to be opened across the freveall GQ Analysis Services amp E Reporting Services amp SQLs Agert s fr OL Server Ag Local connections only E g9 Full Text Search A ti E H Irkegration Services 9 gual omole z E K SAL Seever Browser Using ICPAP only Using named pipes only Using both TCPAP and named pipes Cancel Apply He 3 When you are returned to the SQL Server Surface Area Configuration window as shown in Figure 9 on page 27 now select Surface Area Configuration for Features 4 When the Surface Area Configuration for Features window opens verify that Enable OPENROWSET and OPENDATASOURCE support is selected as shown in Figure 11 on page 29 28 FCWnx 7 7 Global Edition Installation Manual Chapter 2 Windows Server 2003 2008 Standard and Enterpri
172. es 14 Click Finish to save and close this application The settings are automatically saved to your computer What s next Unless otherwise stated in your installation sequence continue the installation for your system by selecting one of the following sequences e Facility Commander Wnx Server Computers e Global configuration Global database server Setting services to automatic startup on page 109 e Global configuration Regional database server Setting services to automatic startup on page 188 e Facility Commander Wnx Client Computers Setting services to automatic startup on page 258 FCWnx 7 7 Global Edition Installation Manual 237 Chapter 7 Windows 7 Vista and XP Professional system setup Summary This chapter provides specific information about setting up a Windows 7 Windows Vista or Windows XP Professional computer as a Facility Commander Wnx client computer We recommend that you read these sections carefully before you begin the installation Perform the steps in the order given Each client computer will run the Facility Commander Wnx application and Imaging package Content Preinstallation checklist 240 Network card 240 Configure the computer for the network 241 Determining computer type 241 Adding the computer to a domain 241 Adding the computer to an existing domain 241 Installing the operating system 242 Assigning user passwords 242 Setting up your monitor 242 Setting the netwo
173. es the database snapshot taken by the Snapshot Agent to the Regional 5 database A schedule is updated to operate every day every one minute and set to run As records are added deleted or updated on Regional Servers or the Global database server the changes are replicated to all database Subscribers A new history transactional publication is created on the Regional database server The name of the publication will be similar to the following SecurePerfectHistory SPHistoryPublication A subscription to this publication is created 6 on the Global database server The name of this subscription is Global servername SPSQL SecurePerfectHistory Each Region s history is replicated to the Global database server but it does not redistribute Regional data to another Region History data is a one way replication A new push subscription is created on the Region a snapshot is started and the Transactional Agent is run Note For each history publication on the Regional server there is a corresponding subscription on the Global server while the SecurePerfect database publication has multiple subscribers 5 A message opens FCWnx Database successfully created Note A log file is created when the Create Database program is run The log file called CreateDatabaseLog is found in the Logs folder The Integrity utility runs automatically following a database creation No user interaction is required Refer to your Facility Command
174. f not already done install the Windows 2003 or Windows 2008 operating system but do not install Microsoft SQL 3 You must be logged in as administrator user to the domain If not log off and log back on as a user with administrator permissions 4 Insert the Facility Commander Wnx installation disc into the CD DVD drive 5 When the AutoPlay window opens click Run SETUP EXE 6 When Facility Commander Wnx starts click Install If the disc does not launch you must manually start the software Using Windows Explorer navigate to the FCWnx Installation disc and double click Setup exe A series of windows open as the listed components install Answer the prompts as appropriate and continue This takes several minutes e NET Framework Windows Installer Installing non English operating systems During installation the installation process checks your system for minimum required components If the following Microsoft Windows components are not detected installation is halted e NET Framework FCWnx 7 7 Global Edition Installation Manual 145 Chapter 4 Install Global Edition Regional configuration A popup message opens informing you that installation will be cancelled until you install the required software in the appropriate language to the operating system you are installing You cannot install Facility Commander Wnx until this is accomplished The following components cause the system to restart when a new version is i
175. fault Password e Change Password If you select this option enter your new password and then enter a second time 11 Click Next to continue The Ready to Install the Application window opens 12 The default Destination Folder is indicated You may want to install to another location Click Browse to navigate to the program folder of your choice for placement of Facility Commander Wnx files 13 Click Next to continue Facility Commander Wnx copies system files updates the system configuration and displays the Facility Commander Wnx icon on your desktop This may take a few minutes FCWnx 7 7 Global Edition Installation Manual 91 Chapter 3 Installing Facility Commander Wnx Global configuration 14 When the Facility Commander Wnx has been successfully installed window opens click Finish The FCWnx License Setup window opens 15 Continue with Licensing your Facility Commander Wnx system on page 108 Each component on a separate computer Components Computer 1 Computer 2 Computer 3 Database server v File server v FCWnx client application 4 Note This configuration has the database server installed on Computer 1 the file server installed on Computer 2 and the FCWnx client application installed on Computer 3 Database server on first computer To install each Facility Commander Wnx component to a separate computer you must begin with the database server installation on the first computer To install the d
176. figuration Figure 117 Create Convert Database 3 196 Create Convert Database FCWnx 7 7 Database Collect login information To begin the database create convert process please supply the SQL Server SQL 2008 Express administrators username and password in the following text box es Click Next The Create Database Initialize the Database Creation window opens as shown in Figure 75 Each Facility Commander Wnx database consists of data files and transaction logs You have an option to place those components in different physical locations You may consider this if your IT Department has certain policies regarding database installation Consult with your IT Department for assistance Data File Directory The Data File Directory field displays the default directory Accept the default as displayed or click the Browse button and browse to any folder location where data files will be stored Note If you are installing in a Cluster configuration the Distributor installs to the same path as the Cluster Data File directory Log File Directory The Log File Directory field displays the default directory Accept the default or click the Browse button and browse to the folder location where database log files will be stored Note This refers to the database logs this does NOT refer to the Facility Commander Wnx logs FCWnx 7 7 Global Edition Installation Manual Chapter 4 Install Global Edition Regional confi
177. file server Firewall is ON File and Printer Sharing must be selected enabled on the Exceptions tab 8 The Path for license information file located on the File Server may have a default path listed Verify the path or click Browse to navigate to the application folder for this application then License Info file of the server computer Select and click the file name It now displays in the Path for license information file located on the File Server field 9 Click Register The license program exits The system registers the license key for this client and the software for this application is licensed for use A message displays informing you that the license setup was successful and services for this application will be stopped 10 A summary of your license displays in the About window of Facility Commander Wnx Refer to About Facility Commander Wnx license summary on page 232 11 Following the licensing sequence return to your installation sequence Note License controllers and clients must re license if the network card has been changed or the computer replaced If the license controller computer is re licensed ALL clients must be re licensed If you do not license during the Facility Commander Wnx installation sequence If you do not license during the installation sequence installation completes and operation of your system continues in Demo Mode until you properly license your system Refer to Running in demo
178. following text box es m Database Server instance Name 3 Click Next The Create Database Initialize the Database Creation window opens as shown in Figure 108 Each Facility Commander Wnx database consists of data files and transaction logs You have an option to place those components in different physical locations You may consider this if your IT Department has certain policies regarding database installation Consult with your IT Department for assistance Data File Directory The Data File Directory field displays the default directory Accept the default as displayed or click the Browse button and browse to any folder location where data files will be stored Note If you are installing in a Cluster configuration the Distributor installs to the same path as the Cluster Data File directory FCWnx 7 7 Global Edition Installation Manual 177 Chapter 4 Install Global Edition Regional configuration Log File Directory The Log File Directory field displays the default directory Accept the default or click the Browse button and browse to the folder location where database log files will be stored Note This refers to the database logs this does NOT refer to the Facility Commander Wnx logs Figure 108 Create Database Create Database FCWhnx 7 7 Database Initialize the database creation Q m Database Directory Information C Program Files GE FCWnx Database Program Files GE FCWnx
179. from the controllers and DVRs e FCWhnx Media Server coordinates communications with DVRs and distributing video to clients e FCWnx System Manager coordinates the communications of data between computers and handles Facility Commander Wnx licensing e FCWnx WCF Service is used to integrate external devices into FCWnx FCWnx WebService coordinates communications for Video Management Control VMC These services run regardless of whether anyone is logged in to Windows or Facility Commander Wnx unless Auto Shutdown is enabled on the Client Form In other words the computer must be turned on but no one needs to be logged in These services must be running in order for connection to the client computers and for controllers to communicate with their server computer If you are going to be using an API interface your computer will use a sixth service e FCWnx API Service can be started manually at the time you install an API interface Accessing the Services form To access the Services form To access the Services form 1 Log on with Administrator rights 2 Click Start and then click Control Panel Category view Click Performance Maintenance Administrative Tools and then click Services 266 FCWnx 7 7 Global Edition Installation Manual Chapter 9 Logging on and configuring Facility Commander Wnx Classic view Click Administrative Tools and then click Services 3 The Services window opens Expand the list of se
180. ft SOL Server for replication Global Edition uses Microsoft SQL Server Replication technology ponios requires that SOL Server Services are running using a domain user account that has administrator privileges on both the local machine and also on the other FOWnx database servers that are part of the Global Edition installation The domain and user name should be entered with the following format Domain UserN ame For example SPDomain Secure Domain U ser Name Password Wise Installation Wizard 3 Enter the user domain and username in the format Domain Username or click Browse to navigate the Windows network and select Enter the domain user password in the Password field Click Next The Select Credential Aliasing Option window opens This feature allows you to assign a credential number that represents the encoded credential number This provides added security in that the encoded number is displayed only to authorized users e Do not use aliases indicates no aliasing will be used e Use aliases automatically provided by FCWnx assigns the credential number for you e Use aliases manually provided by user aliasing allows you to assign the number FCWnx 7 7 Global Edition Installation Manual 53 Chapter 3 Installing Facility Commander Wnx Global configuration 7 Choose one aliasing option then click Next The Change the Secure password window opens 8 The Facility Commander Wnx installation cr
181. fully the following firewall and DCOM ports must be configured for server and client communication across your network Table 22 Supported authentications Anonymous Local User Account Domain Account Domain Yes N A Yes Workgroup Yes Not supported N A FCWnx default port assignments FCWnx uses the following default port assignments when installed FCWnx also communicates through DCOM requests via the operating system The operating system dynamically handles the port assignments for DCOM and the default range used for communication are 1024 65535 You can configure DCOM to use TCP rather than RPC at the operating system level effectively optimizing the number of ports required Contact Technical Support for configuration assistance Table 23 Default port assignments Service Port assigned Media server 8085 HTTP inbound from video client 8086 HTTP inbound communication from host 8087 8088 8089 HTTP outbound to host TCP inbound stream requests from video client HTTP outbound to video client Video devices SymSafe SymDec 1024 TCP command and control Random UDP video streams DVMRe and StoreSafe 1024 TCP VisioWave 4001 TCP command and control 4444 TCP event control 11001 TCP storage control 5001 5256 UDP video streams 8001 8256 TCP PTZ control DVSRxU and TruVision 8000 TCP command and control TVR 10 234 FCWnx 7 7 Globa
182. ging or deleting CCTV alarms CCTV alarms are the actual messages that are sent out to the American Dynamics interface They control what sequence of monitors and cameras are switched on and off The American Dynamics controller is preprogrammed to interpret these messages To program the American Dynamics controller refer to the manual on the American Dynamics command console language To add CCTV alarms within FCWnx 1 From the FCWnx Application Group pane select Gateways amp Interfaces then CCTV Interface 2 Click Add 3 Inthe Description field enter the appropriate description for your system Example American Dynamics CCTV Alarm 4 In the CCTV Interface field choose American Dynamics 5 Inthe CCTV Alarm field choose the alarm number of the interface you are monitoring 6 The Enable Message and Disable Message fields are automatically filled Use these default settings Appendix C CCTV Interfaces 7 Inthe Reset CCTV Alarm field two reset choices for the alarm are provided when the alarm is cleared from the Alarm Monitor or when the alarm Resets This means the Reset or the disable message can be sent out when the FCWnx alarm e Is cleared from the Alarm Monitor e Resets 8 Click Save To change CCTV alarms within FCWnx 1 From the FCWnx Application Group pane select Gateways amp Interfaces then CCTV Interface 2 Click Search 3 In the Search Result window locate and then select the CC
183. guration Figure 118 Create Database Create Database es 5 xj FCWnx 7 7 Database Initialize the database creation Q Log View Error m Database Directory Information _ ___ __ C Program Files GE FCWnx Database ae Log File Directory ram Filas GE FCWnx Database View Integrity Report cok e gt oee 4 Click Create Database The database creation begins and a progress bar is displayed This may take a few minutes Caution If a database already exists a warning message will display stating that you are about to overwrite your existing database with an empty default database Order of events Regional database server database creation For information only this is the order of events taking place during the Regional database server database creation No action is required on the part of the user Table 21 Order of Events Regional database server database creation Step Description The Regional database server database is created SecurePerfect 1 SecurePerfectHistory and SecurePerfectArchive The Regional database server contacts the SecurePerfectDistributor and Publisher on the Global database server The Regional database is added to the Subscriber s list at the Publisher and a new push subscription is created The Snapshot Agent is started at the Global Database server computer When the 4 agent completes
184. gure 167 on page 326 provides a basic example of the hardware setup See Hardware requirements on page 326 and for more information 2 Install the FCWnx Kalatel software on the desired FCWnx computer See Installation Kalatel on page 327 3 Add CCTV alarms and then link or map the desired FCWnx alarms to the appropriate CCTV cameras set up in Kalatel Configuring alarms on page 329 and Monitoring on page 337 Appendix C CCTV Interfaces 4 Once the FCWnx and Kalatel systems are set up and configured operation of the CCTV control feature is a hands free procedure Figure 167 Overview of the FCWnx and Kalatel interface 5301190044 Hardware requirements For the Kalatel system e Cable to connect the KTD 304 keypad to the KTD 348 switcher Refer to Figure 168 on page 327 for cable pinout information e CCTV cameras and monitors e KTD 348 controller provided by Kalatel e KTD 304 keypad provided by Kalatel 326 FCWnx 7 7 Global Edition Installation Manual Figure 168 Cable pinouts KTD 304 to KTD 348For the FCWnx System RS 422 CONTROL SIGNAL IN From other keypads or my alarm chassis RS 422 CONTROL SIGNAL OUT s 3 To receivers and matrix switchers MODULAR RS 422 IN A Y YELLOW RS 422 IN B G GREEN RS 422 OUT A WH WHITE RS 422 OUT B BR BROWN 14VDC POWER 0 ORANGE Ain 14VDC POWER 8 BLUE DTMF SIGNAL A R RED a 7 S DT
185. gure 19 Typical Global Replication system overview Global Database Server Regional Database Server Regional Database Server Push inserts of SecurePerfectHistory data to Global Server 42 FCWnx 7 7 Global Edition Installation Manual Chapter 3 Installing Facility Commander Wnx Global configuration Global configuration definitions This list of definitions refers to elements displayed in Figure 19 on page 42 For additional information refer to Microsoft SQL Books Online Table 5 Global configuration definitions Element Description Distributor Global database server Merge replication Publication Publisher Pull Subscription Push Subscription The Distributor is a server that contains the distribution database and stores meta data history data and or transactions In Merge Replication the Distributor also hosts the Snapshot Agent and Merge Agent for push subscriptions When the Distributor is created for an SQL instance it generates its own database to store information Once publishing is enabled on the Global server it is able to control and monitor publications and subscriptions as well as the starting and stopping of replication agents The machine where the Publisher database the Merge Agent and the Distributor Agent reside The Global database server is the main Facility Commander Wnx database server This means that the Global database server acts as a hub for all re
186. hapter 8 Installing Facility Commander Wnx Software on additional clients 6 When the Select Groups window displays select those groups from the list of Names to which you are adding the user login click Add then click OK The window should look similar to Figure 153 The operator running the Facility Commander Wnx and Imaging systems is a member of the groups listed Figure 153 Login Groups Properties window General Member Of Profile Member of Power Users Client folder structure During installation of Facility Commander Wnx software the following folders are created English Graphics Logs and Rpt If this is a Custom installation the Graphics folder is on the file server Some of the folders are shared This allows other computers to gain access to the information stored in these folders as long as they logged in as an authorized user FCWnx 7 7 Global Edition Installation Manual 263 Chapter 8 Installing Facility Commander Wnx Software on additional clients Client folders To review a description of the folders in your FCWnx directory refer to the following Table 25 Client folders Folder Description Config A folder that contains website configurations for the FCWnx Web Service The FCWnx Web Service is used by VMC to communicate with FCWnx English The files required to display the Facility Commander Wnx client software in English As more languages are installed more language specific
187. he Secure password window Change the Secure password Change the password for the Windows Logon USERID Secure The FC Wnx installation creates a new Windows USERID called Secure By defauk the password is SecuntyMaster08 If your Windows network has secunty policies that enforce rules for password creation you may want to change the Secure user password If you are unsure ack your System Administrator Use Defauk Password Change Password New Password eeeeeeeeeeeeoeee Repeat New Password Next gt 7 The Facility Commander Wnx installation creates a new Windows User ID 8 9 called Secure By default the password is SecurityMaster08 case sensitive If your Windows network has security policies that enforce rules for password creation you may need to change the secure user password If you are unsure ask your system administrator Select one of the following e Use Default Password e Change Password Enter your new password and then enter a second time Note This password must be the same for all computers in the Facility Commander Wnx system Click Next The Ready to Install the Application window displays The default Destination Folder is indicated You may want to install to another location Click Browse to navigate to another program folder for placement of Facility Commander Wnx files 10 Click Next to continue Facility Commander Wnx copies system files updates the syste
188. he Database and File Server Paths window opens as shown in Figure 59 If a displayed Database Server Name is not correct enter or select the appropriate name from the drop down list If a displayed File Server Name is not correct navigate to the file server computer for this client and select to display in the File Server Name dialog box FCWnx 7 7 Global Edition Installation Manual Chapter 3 Installing Facility Commander Wnx Global configuration Figure 59 Database and file server paths Global Database and FileServer Paths O Global Database Server Name Database Server Name z File Server Name B Browse Wise Installation Wizard oo We cs 8 Click Next The Change the Secure password window opens 9 Select one of the following e Use Default Password e Change Password If you select this option enter your new password and then enter a second time 10 Click Next The Ready to Install the Application window opens The default Destination Folder is indicated You may want to install to another location Click Browse to navigate to the program folder of your choice for placement of Facility Commander Wnx files 11 Click Next to continue Facility Commander Wnx copies system files updates the system configuration and displays the Facility Commander Wnx icon on your desktop This may take a few minutes 12 When the Facility Commander Wnx has been successfully installed window opens clic
189. he action Click Yes 5 Uninstall begins and a status bar indicates the uninstall progress Once the uninstall begins the Cancel button is unavailable 6 When uninstall is complete click Finish then exit the Add Remove Programs window and the Control Panel The database and log files are NOT removed during the uninstall of Facility Commander Wnx on the server computer The database and log files are NOT removed during the uninstall of Facility Commander Wnx on the server computer If the uninstall does not proceed hangs do the following 1 Press Ctrl Alt Delete The Windows Security Dialog opens 2 Click Task Manager 3 At the Task Manager window Facility Commander Wnx 7 7 will display a status of Not Responding 4 Select the line Facility Commander Wnx 7 7 and click End Task 5 At the next dialog click End Task again Uninstalling Facility Commander Wnx installed components Note Facility Commander Wnx 7 7 also installs the following components If you want to completely remove all installed components proceed with the following procedure e Facility Commander Wnx 7 7 Imaging Runtime e Facility Commander Wnx 7 7 Crystal Reports Runtime FCWnx 7 7 Global Edition Installation Manual 289 Chapter 12 Uninstall Facility Commander Wnx or delete a database To uninstall Facility Commander Wnx 7 7 Imaging Runtime and Facility Commander Wnx 7 7 Crystal Reports Runtime 1 Log on as someone with administrative pri
190. ick Network Sharing Center Click Manage network connections FCWnx 7 7 Global Edition Installation Manual 13 Chapter 2 Windows Server 2003 2008 Standard and Enterprise Edition Server setup 3 Right click the Local Area Connection and then select Properties The Local Area Connection Properties window opens 4 Select Internet Protocol Version 4 TCP IPv4 and Version 6 TCP IPv6 Note If Version 6 is enabled on the server it must be enabled on the client 5 Click Properties 6 Select one e Obtain an IP address automatically e Use the following IP address Note Facility Commander Wnx computers do not require static IP addresses However if you selected Use the following IP address option you must obtain a valid IP address from the network administrator or use a local IP address that no other computer is using in your network Consult your network administrator for detailed instructions 7 Click OK 8 Click OK to exit Local Area Connection Properties 9 After Windows is installed restart the computer and make sure it is connected to the network Verify that you do not have any hardware errors under Device Manager Windows firewall Windows Server 2003 Firewall exceptions list If the firewall is selected ON File and Printer Sharing on the firewall exceptions list must be enabled To enable File and Printer Sharing 1 Click Start and then click Control Panel 2 On the control panel double click Windows Firew
191. ick the Distributed File System Snap in to display a shortcut menu as displayed in Figure 125 Figure 125 Distributed File System Snap In Shortcut Menu A Distributed File System le File Action View Help e Amene RM amp s Distributed File System ga TEST Replication Enabled New Link New Root Target Check Status Filter Links Hide Root Delete Root View Refresh Export List Properties Help Number of links 0 displayed 0 total 206 FCWnx 7 7 Global Edition Installation Manual 2 Select New Link The New Link window opens similar to Figure 126 Chapter 5 Configuring Global Edition for file replication 3 In the New Link window Enter one of the FCWnx shared folder names as the FOWnx Link Name folder to replicate Enter the name of the appropriate FCWnx shared folder name in the Comments dialog box such as FCWnx xxxx Folder Share where xxxx is the name of the folder Figure 126 New Link 4 Click OK The Distributed File System snap in with Replication displays Le Enter a name and path for the new link When users open this link they are redirected to the shared folder you select as the target Link name Video Preview of UNC path to the link WBOCANR eplication Video Path to target shared folder MT est Video Browse Comments Fewn Video Folder Share Amount of time clients cache this referral in seconds 1800 Carc
192. iguration database server and file server re Facility Commander Wnx 7 7 Setup FCVnx Global Custom Configuration aS Choose the appropriate components for a custom Global Edition installation IV Database Server Choosing this option will install the FCW nx database components Please select which type of server Global Only one of these per FCW nx Global Edition installation C Regional There can be several of these for an FCWnx Global Edition installati IV File Server Choosing this option will install the FCwnx File Server components I FCWnx Client Application Choosing this option will install the FCwnx Client Application Wise Installation Wizard ook ie ces 2 The Logon Account for SQL Server Services window opens as shown in Figure 27 on page 59 Note Each server used in the Facility Commander Wnx Global Edition system requires the database services to run under a domain user name and password account This account must have administrative privileges to that particular computer We suggest that you use the identical domain account at each computer used in the UTC Fire amp Security system 58 FCWnx 7 7 Global Edition Installation Manual Chapter 3 Installing Facility Commander Wnx Global configuration Figure 27 Logon account for SQL server services Facility Commander Wnx 7 7 Setup Te xi Logon Account for SOL Server Services Enter the domain user account to be used by Micro
193. ile Replication Adomain controller does not require a FCWnx system installed to host File Replication services e Distributed File System file replication can only be created on a domain controller computer e Verify that all FCWnx shared folders on each server computer intended for participation in replication have SPAdmin permission and Domain Administrator permissions Those folders include e Designs e Externals e Firmware e Video e Verify that the Facility Commander Wnx share folders exist on all FCWnx server computers that will be hosting File Replication 200 FCWnx 7 7 Global Edition Installation Manual Chapter 5 Configuring Global Edition for file replication File Replication on Windows 2003 with SQL 2005 Note The following instructions use examples of Windows 2003 Standard Edition Server The properties and windows deviate somewhat in Windows 2003 Standard Edition Server Verifying Distributed File System service is started Before you continue verify that the Distributed File System service is started To verify the Distributed File System service is started 1 Click Start Settings Control Panel Administrative Tools and then Services The Services window opens 2 Select Distributed File System 3 The status will be either Started or blank If it is blank then the service is not running and needs to be started 4 Right click and select Properties In the Startup type field select Automatic
194. ility Commander Wnx User Manual installed in the UserManuals folder of the FCWnx installation folder and found on the Documentation CD shipped with your Facility Commander Wnx system For Windows Clustering Technologies refer to the document Installing Facility Commander Wnx in a Clustered Environment included on the Documentation CD shipped with your Facility Commander Wnx system Unless otherwise noted details for each step can be found in the chapters that follow Upgrades If you are upgrading from a previous version of Facility Commander Wnx software contact Technical Support Prepare and install FCWnx Global database server Note We recommend that you do not add clients or devices to the Global Database server computer For optimal functionality the Global database server in your Facility Commander Wnx system should be dedicated to the replication process Table 2 Steps to prepare and install a Facility Commander Wnx Global database server Task Reference Check minimum hardware and software requirements on page 2 B Install network board on page 10 C Determine server type on page 10 D Install prepare the operating system on page 11 E Add this server to the primary domain controller of your existing on page 15 or new domain F Install Microsoft SQL Server on page 17 G Prepare and install Facility Commander Wnx software on page 44 H License the system on page 226 Verify that Facility Commander Wnx services are
195. in Select the following options and then click Next Instance Features e Database Engine Services e SQL Server Replication e Full Text Search Shared Features e Client Tools Connectivity e Client Tools Backwards Compatibility e Management Tools Basic e Management Tools Complete Figure 13 Feature Selection T SQL Server 2008 Setup Description Client Tools Backwards Compatibility Feature Selection Select the Standard features to install For clustered installations only Database Engine Services and Analysis Services canbe clustered Setup Support Rules Features Feature Selection Instance Features Instance Configuration M Database Engine Services Disk Space Requirements SQL Server Replication Beyer Canaan V Full Text Search Analysis Services Database Engine Configuration C Reporting Services Error and Usage Reporting Shared Features Installation Rules F Business Intelligence Development Studio M Client Tools Connectivity ae o Integration Services Installation Progress M Complete C Client Tools SDK SQL Server Books Online V Management Tools Basic V Management Tools Complete SQL Client Connectivity SDK Microsoft Sync Framework Redistributable Features Select All Unselect ll Shared feature directory C Program Files Microsoft SQL Server A Rar Mawn I Cancel Halna 17 The Instance Configuration window open
196. indow e Use Default Password e Change Password Enter your new password and then enter a second time Click Next The Ready to Install the Application window opens Enter the SQL Server password for the sa user This password was previously created during installation of SQL Refer to Installing Microsoft SQL Server on page 17 FCWnx 7 7 Global Edition Installation Manual Chapter 4 Install Global Edition Regional configuration Note Enter your previously assigned SQL password here If you purchased your Facility Commander Wnx system from UTC Fire amp Security a temporary password of SecurityMaster08 case sensitive was assigned for you 8 The default Destination Folder is indicated You may want to install to another location Click Browse to navigate to the program folder of your choice for placement of Facility Commander Wnx files 9 Click Next to continue Facility Commander Wnx copies system files updates the system configuration and displays the Facility Commander Wnx icon on your desktop This may take a few minutes 10 When the Facility Commander Wnx has been successfully installed window opens click Finish 11 If your computer restarts log on and continue Creating the database custom installation To install the Regional database server 1 The Select Database Server Type window opens as shown in Figure 79 Select Regional Database Server and in the Select Global Database Server field
197. indow opens as shown in Figure 5 FCWnx 7 7 Global Edition Installation Manual 21 Chapter 2 Windows Server 2003 2008 Standard and Enterprise Edition Server setup Figure 5 Instance Name i Microsoft SQL Server 2005 Setup E xj Instance Name You can install a default instance or you can specify a named 4 instance ag i Provide a name for the instance For a default installation click Default instance and click Next To upgrade an existing default instance click Default instance To upgrade an existing named instance select Named instance and specify the instance name Default instance Named instance sPsQL coe e e 16 Select Named Instance and enter SPSQL Click Next Note It is very important that you enter the correct instance for the appropriate product 17 The Service Account window opens as shown in Figure 6 e Ifyou select Use the built in System account verify that Local system displays in the dialog box e Inthe Start services at the end of setup grouping select SQL Server and SQL Browser Click Next If you select SQL Server Agent at this time you do not have to set properties later as described in Setting SQL Server Agent properties on page 26 e Click Next 22 FCWnx 7 7 Global Edition Installation Manual Chapter 2 Windows Server 2003 2008 Standard and Enterprise Edition Server setup Figure 6 Service Account iz Microsoft SQL Server 2005 Setup S
198. ing or disabling Simple File Sharing has no effect Simple File Sharing always remains disabled for computers joined to domains Firewall exceptions list If the Firewall is selected ON File and Printer Sharing on the Firewall Exceptions list must be enabled To enable File and Printer Sharing 1 Click Start and then click Control Panel 2 On the control panel double click Security Center and then click Windows Firewall 3 On the Exceptions tab make sure that theFile and Printer Sharing check box is checked and then click OK Items specific to Windows Vista Windows communication foundation HTTP activation If the Video Management Console VMC will be running on this computer Windows Communication Foundation HTTP Activation must be enabled To enable Windows Communication Foundation HTTP Activation 1 Click Start Control Panel and then Programs and Features 2 Select Turn Windows features on or off from the Tasks panel on the left 3 Search for Microsoft NET Framework 3 5 and then enable check box Windows Communication Foundation HTTP Activation 246 FCWnx 7 7 Global Edition Installation Manual Chapter 7 Windows 7 Vista and XP Professional system setup Firewall exceptions list If the Firewall is selected ON the following must be enabled in the Firewall Exceptions list e File and Printer Sharing e Network discovery e Workgroup Only Remote Administration To enable Firewall Exceptions selections
199. inked CCTV cameras and monitors The Burle Allegiant system then controls the appropriate cameras and monitors No operator intervention is required As an alarm is cleared by the operator from the FCWnx Alarm Monitor form or when the FCWnx alarm resets the Burle Allegiant system is informed that the alarm is now reset and responded to and the appropriate camera turns off Setup overview To perform a successful configuration 1 Setup the FCWnx system and the Burle Allegiant system or verify the setup if this is an existing system Figure 164 on page 320 on the next page provides a basic example of the hardware setup See Hardware requirements on page 320for more information 2 Install the FCWnx Burle Allegiant software on the FCWnx computer Installation Burle Allegiant on page 321 3 Add CCTV alarms and then link or map the FCWnx alarms to the appropriate CCTV cameras set up in Burle Allegiant See Configuring alarms on page 323 and Monitoring on page 337 4 Once the FCWnx and Burle Allegiant systems are set up and configured operation of the CCTV control feature is a hands free procedure Appendix C CCTV Interfaces Figure 164 Overview of the FCWnx and Burle Allegiant interface 53012034 Hardware requirements For the Burle Allegiant system Allegiant Models TC8500 through TC8901 controller provided by Burle e CCTV cameras and monitors Note Refer to your Allegiant manual for
200. installed you will need to do so now To install SQL Server 2008 Service Pack 1 1 Insert the FCWnx Windows Updates disc into the CD DVD drive 2 Navigate to the SQL Server 2008 SP1 folder 3 Double click on the file SQLServer2008SP 1 KB968369 x86 ENU exe 32 bit or SQLServer2008SP 1 KB968369 x64 ENU exe 64 bit 4 Follow the on screen instructions When prompted make sure that you select the SPSQL instance 5 We recommend that you restart your computer at this time Windows Server 2008 communication foundation HTTP activation Windows Communication Foundation HTTP Activation must be enabled on Window Server 2008 servers To enable Windows Communication Foundation HTTP Activation 1 Click Start Control Panel and then double click Programs and Features 2 Select Turn Windows features on or off from the Tasks panel on the left 3 On the left pane under Server Manager click Features A list of installed features is displayed in the right pane under Features Summary 4 If Windows Communication Foundation HTTP Activation is not installed click Add Features The Add Features Wizard opens 5 Expand the gt NET Framework Activation tree and then expand the WCF Activation tree Check the HTTP Activation check box A pop up opens displaying the role services required for HTTP Activation Click Add Required Role Services 6 Click Next The Web Server IIS page opens Click Next 7 The Select Role Services page op
201. ion only The Browse button is enabled and allows selection of file server license information path to give the user an opportunity to log in to the remote computer if the currently logged in user does not have permissions for the folder Click Register 9 The SQL Server Login dialog box may display as shown in Figure 144 SQL Server Login dialog box with data Clear the Use Trusted Connection check box if checked and enter Login ID as sa and enter sa s Password If you purchased your system from UTC Fire amp Security a temporary password of SecurityMaster08 case sensitive was assigned We recommend that you enter a password of your choice Click OK Figure 144 SQL Server Login dialog box with data Data Source FC Wnx SOL Use Trusted Connection Cancel Login ID ba st Help Password Options gt gt 10 The license program exits The system registers the license key for this client and the software is licensed for use A message displays informing you that the license setup was successful and services will be stopped FCWnx 7 7 Global Edition Installation Manual 231 Chapter 9 License and Set Security Settings for your FCWnx System 11 Following the licensing sequence a summary of your license displays in the About window of each client computer Refer to About Facility Commander Wnx license summary below for additional details 12 You are ready to log on Refer to Chapter 9
202. irst Then you need to map the desired FCWnx alarm to CCTV on the Alarm form CCTV tab Configuring alarms below and Monitoring on page 337 14 To start your CCTV interface click Launch Client on the toolbar while the CCTV interface is selected This starts the program that communicates with your CCTV switcher Configuring alarms The communication between the FCWnx system and the Kalatel system is a one way communication FCWnx only sends data to the Kalatel switcher it does not receive any messages from Kalatel If the Kalatel switcher loses communications with the FCWnx system there is not be a Loss of COMM alarm generated on the FCWnx system Only the loss of Client COMM alarm is installed in the Kalatel interface This alarm is generated from FCWnx when the FCWnx server is no longer able to communicate with the interface program Alarms from FCWnx The FCWnx Kalatel interface allows FCWnx alarms to trigger CCTV cameras monitors to turn on or off on the Kalatel system Before this can happen FCWnx needs to be notified as to which FCWnx alarms are to be the triggers and which messages need to be sent to the Kalatel system to trigger cameras monitors To configure correctly follow the steps below Each step is explained in more detail in the sections that follow 1 Add change or delete the desired CCTV alarms Adding changing or deleting CCTV alarms below 2 Map FCWnx alarms to CCTV alarms See Mappi
203. is found in the Logs folder The Integrity utility runs automatically following a database creation No user interaction is required Refer to your Facility Commander Wnx Online Help for addition information about the Integrity utility Click OK The dialog box closes If you receive a message to restart at this time click Yes to restart log on and continue 9 An FCWnx License Setup window opens Unless otherwise stated in your configuration scenario proceed to Licensing your Facility Commander Wnx system on page 187 144 FCWnx 7 7 Global Edition Installation Manual Chapter 4 Install Global Edition Regional configuration 10 Remove the Facility Commander Wnx installation disc and continue with instructions to install FCWnx Client Application FCWnx client application on second computer Windows XP Professional Windows Vista or Windows 7 operating system Note Prerequisite Database server installation and file server installation already complete Continue with instructions as listed in Chapter 8 Installing Facility Commander Wnx Software on additional clients on page 249 Follow the instructions for custom installations Windows 2003 or Windows 2008 Server operating system Note Prerequisite Database server installation and file server installation already complete To install the FCWnx client application on the second computer 1 Verify that the computer you are configuring meets minimum requirements 2 I
204. ist below Fe o This option will install a Global Database Server and CID Daane Hory Distributor SQL Server must already be installed with an instance of SPSQL This option will install the Regional Database Server C Regional Database Server on a local client A Distributor must be selected from ist below Select Global Database Server l ca 2 The Create Convert Database window opens Ignore the sa User Name as displayed The Password field displays your previously assigned and encrypted SQL password If you purchased your Facility Commander Wnx system from UTC Fire amp Security a temporary password of SecurityMaster08 case sensitive was assigned for you Accept the password as displayed FCWnx 7 7 Global Edition Installation Manual 61 Chapter 3 Installing Facility Commander Wnx Global configuration Figure 29 Create Database Global database server 3 62 amp Create Convert Database el BS FCWhnx 7 7 Database Collect login information Q To begin the database create convert process please supply the SQL Server SQL 2008 Express administrators username and password in the following text box es Database Server Instance Name Click Next The Create Database Initialize the Database Creation window opens Each Facility Commander Wnx database consists of data files and transaction logs You have an option to place those components in different physical locations You may co
205. ition window displays Click Yes this computer is part of an FCWnx Global Edition installation and then click Next 3 The Install FOWnx Client Server window displays as shown in Figure 149 FCWnx 7 7 Global Edition Installation Manual 255 Chapter 8 Installing Facility Commander Wnx Software on additional clients Figure 149 Custom Install FCWnx Client Server instal FOWhx Client Server To Select the Type of Installation A C Sever Server install wil install the FCW nx Server on this computer Chent DATABASE SERVER Enter the SOL Server Instance name of the FCWnx Database and the computer name of the FCWnx File Server for this client or browse on the Windows network Database Server gt File Server Browse Wise Installation Wizard we a lt Back __ Cancel 4 Select Client The Database Server field is now available Enter the name of the FCWnx database server and SPSQL instance such as DATABASESERVER SPSQL or select from the drop down list of available server computers for this client 5 Enter the File Server for this client or Browse for the File Server name on the Windows network These are the server computers you configured in the previous chapters 6 Click Next The Change the Secure password window displays as shown in Figure 150 256 FCWnx 7 7 Global Edition Installation Manual Chapter 8 Installing Facility Commander Wnx Software on additional clients Figure 150 Change t
206. ive a message to restart at this time click Yes to restart log on and continue 10 An FCWnx License Setup window opens Unless otherwise stated in your configuration scenario proceed to Licensing your Facility Commander Wnx system on page 108 FCWnx 7 7 Global Edition Installation Manual 119 Chapter 3 Installing Facility Commander Wnx Global configuration What s next 1 If you have not already done so remove the Facility Commander Wnx installation disc from your CD DVD drive You have completed the Global setup 2 If you have not licensed your system do so now You must license your Global Edition system before you can proceed to configure Regional database servers Refer to Chapter 6 License and Set Security Settings for your FCWnx System on page 225 3 Proceed to set up additional Regional server computers on your Facility Commander Wnx system Note Following configuration of each new client installation all currently installed Facility Commander Wnx Global Edition server computers and client computers must be restarted in order to be recognized 120 FCWnx 7 7 Global Edition Installation Manual Chapter 4 Install Global Edition Regional configuration Summary This chapter continues your system configuration of a Facility Commander Wnx Global Edition Regional configuration We recommend that you review the entire chapter and discuss with your IT Department before you begin your configuration Cont
207. k Finish 13 Continue with Licensing your Facility Commander Wnx system on page 108 FCWnx 7 7 Global Edition Installation Manual 107 Chapter 3 Installing Facility Commander Wnx Global configuration When Global custom configurations are complete Note Proceed to Licensing your Facility Commander Wnx system below if you have not already licensed Licensing your Facility Commander Wnx system To license your Facility Commander Wnx system at this time After obtaining your registered license key as shown instructed in Chapter 6 License and Set Security Settings for your FOWnx System on page 225 follow one of the sequences listed e First time license on page 227 e Running in demo mode on page 229 e lf you do not license during the Facility Commander Wnx installation sequence on page 230 Note When you have completed a successful licensing sequence return to this point and continue After a successful licensing sequence or if you click Cancel to license at another time 1 You may receive an Facility Commander Wnx Installation Complete dialog box If so click Yes to restart your computer 2 Log on as administrator and continue with Setting services to automatic startup on page 109 Configuring security settings The Security Configuration utility launches immediately following the License Setup and assists you in configuring firewall and DCOM settings on your computer Check
208. l Provides instructions for installation and wiring for ACU controllers and associated hardware These documents and others are included on the Documentation disc shipped with your Facility Commander Wnx system in PDF format You must have Adobe Acrobat Reader installed on your computer to view PDF documents For your convenience a copy of the Adobe Acrobat Reader software is included on the disc vi FCWnx 7 7 Global Edition Installation Manual Chapter 1 Introduction to Facility Commander Wnx Summary This chapter provides a list of prerequisites for a successful Facility Commander Wnx Global system as well as step by step instructions for installation Follow instructions in the order presented Content Recommended minimum requirements 2 Hardware 2 Software 3 Integrated video management 4 Before you begin 4 Installation and setup outlines 5 Prepare and install FCWnx Global database server 5 Prepare and install FCWnx Regional database server 6 Prepare and install an FCWnx client computer 6 FCWnx 7 7 Global Edition Installation Manual Chapter 1 Introduction to Facility Commander Wnx Recommended minimum requirements Facility Commander Wnx is designed to operate on a system that meets these minimum requirements for hardware and third party software When configuring a database server to utilize RAID technology we do not recommend using RAID5 Contact Technical Support for information on RAID configurations Hardw
209. l Edition Installation Manual Chapter 9 License and Set Security Settings for your FCWnx System Service Port assigned Integral 18772 TCP command and control Intellex 5000 5002 TCP command and control Nice 2024 TCP command and control Panasonic 80 HTTP command and control Pelco 9002 TCP command and control You must be logged in as an administrator to the domain to run the SecurityCnfg Utility If not log off and log back on as a user with these permissions This application is launched one of three ways Auto launches immediately following the licensing sequence Select Configure Ports on the main File menu of FCWnx Click Start then select Programs Facility Commander Wnx then Security Configuration Once the program starts 1 The Communications Ports for Clients window opens This displays the low and high range for the ports used for TCP and UDP filtering Accept the given port values or change to suit your installation If you need to change the ports contact your IT department to make sure there are no port conflicts Click Next to continue The settings are automatically saved to your computer The DCOM User and password window opens The Default check box is checked by default which means this application uses secure authentication That is DCOM authentication is verified using the secure user account created during FCWnx installation DCOM communication is configu
210. lation of FCWnx is now complete 6 Thin Client software must be installed on all computers that are going to connect to the Thin Client Server and access FCWnx 7 Your FCWnx software license limits the number of Thin Client installations allowed Setting up a Digi serial port expander Note If you purchased this system from UTC Fire amp Security the Digi board is already set up for you The Digi serial port expander is a UTC Fire amp Security approved serial port expander The purpose of the Digi serial port expander is to provide additional COM ports which are required for wiring direct connect micros and communicating with dial up micros using modems Note If you plan on using CCTV devices to interface with FCWnx you need additional serial ports therefore you need a Digi serial port expander However integrated digital video recorders and equipment use an ethernet interface To install or change the configuration of the Digi serial port expander 1 Shut down the computer and turn the power off Remove the power cord from the back of the computer Stand by power causes the system to automatically start up on the insertion of a new card of any type into the PCI bus 2 Open the computer and install the Digi board into any free PCI slot of the motherboard Secure the card to the computer chassis 3 Close the computer case and connect the Digi box to the cable from the Digi board that you just installed 4 Turn the
211. lects the speed that your modem uses to attempt a connection with the remote modem This is the data transmission speed across the telephone line from modem to modem If the remote modem does not support the speed specified by S37 your modem attempts to connect at the next lower speed This continues until a connection is made the options are exhausted or the remote modem times out 9 9600 bits second If you have problems at 9600 you can try a lower baud rate 8 4800 bits second 7 2400 bits second 5 Click OK 6 Click OK again 7 Click Close Setting up the Fargo DTC550 printer encoder for smartcard encoding with FCWnx To use the Fargo DTC550 printer encoder with FCWnx you must download and install the printer driver If you are using a Fargo printer with an internal OMNIKEY 5121 or 5125 encoder you must download and install both the driver and API Notes Make sure that the operating system is installed on an NTFS partition FCWnx 7 7 Global Edition Installation Manual 307 Appendix B Optional hardware and software Do not have a Magstripe encoder specified under Printer Setup Make sure it is set to None Do not have an external encoder configured when trying to use the internal encoder of the printer To download and install the DCT 550 driver 1 2 Log on to your computer as the local administrator Before connecting the printer USB cables to the computer download the DTC 550 driver from the foll
212. lete 3 Next continue with Deleting the database on page 291 290 FCWnx 7 7 Global Edition Installation Manual Chapter 12 Uninstall Facility Commander Wnx or delete a database Deleting the database Caution The following steps cannot be done if you have already uninstalled Microsoft SQL Server As we have mentioned earlier the database is NOT removed when you uninstall Facility Commander Wnx from the server computer Caution Make a backup of your database before performing these steps To delete the FCWnx databases 1 Click Start Programs Microsoft SQL Server 2005 or 2008 and then SQL Server Management Studio 2 At the Connect to Server window verify that the Login and Password are correct then click Connect Locate and open the Databases folder Right click SecurePerfectHistory to display the shortcut menu At the menu select Delete The Delete Object window opens Click Ok to delete this database Right click SecurePerfectArchive to display the shortcut menu OOS OP E a E E Select Delete 9 The Delete Object window opens Click Ok to delete this database 10 Right click SecurePerfect to display the shortcut menu 11 Select Delete 12 The Delete Object window opens Click Ok to delete this database 13 From the Microsoft SQL Server Management Studio main menu select File then Exit Removing Microsoft SQL Server Caution Removing Microsoft SQL Server will delete all Facility Commander
213. licated Provision for switchover within 6 minutes is required 30 seconds for manual transfer of cables and 5 minutes 30 seconds for the system boot sequence 2 Compatibility has been verified with the following protected premise control units e ACU2X ACU2XL8 ACU2XL16 ACURSO2 ACURS04 ACUX16 e M5 M3000 and Micro 2000 using a PXN or PXNplus CPU board e DirecDoor 3 The system shall be connected to a listed surge suppressor with a maximum marked rating of 330 volts 4 The installation instructions shall specify signal line transient protection complying with the Standard for Protectors for Data Communications and Fire Alarm Circuits UL 479B with a maximum marked rating of 50 volts 5 The equipment shall be installed in a temperature controlled environment Twenty four hours of backup power shall be provided to the HVAC system The HVAC system shall be capable of maintaining a temperature between 55 and 95 F 6 The installation instructions shall specify that in addition to the main power supply and secondary power supply that are required to be provided at the central supervisory station the system shall be provided with an uninterruptable power supply UPS with sufficient capacity to operate the computer equipment for a minimum of 15 minutes If more than 15 minutes is required for the secondary power supply to supply the UPS input power the UPS shall be capable of providing input power for at least that amount of time
214. ll be installed This option is recommended for mast users Use this option to choose which application features you want installed and where they will be installed Recommended for advanced users Click Next The Install Facility Commander Wnx Client Server window opens When asked Is this computer part of a Facility Commander Wnx Global Edition installation select Yes 6 Click Next The FCWnx Global Custom Configuration window opens as shown in Figure 111 Check the check box for only FCWnx Client Application 184 FCWnx 7 7 Global Edition Installation Manual Chapter 4 Install Global Edition Regional configuration Figure 111 FCWnx Global Custom configuration FCWnx Client Application Facility Commander Wnx 7 7 Setup FCviinx Global Custom Configuration Choose the appropriate components for a custom Global E dition installation 7 Click Next The Database and File Server Paths window opens as shown in Figure 112 If a displayed Database Server Name is not correct enter or select the appropriate name from the drop down list If a displayed File Server Name is not correct navigate to the file server computer for this client and select to display in the File Server Name dialog box FCWnx 7 7 Global Edition Installation Manual 185 Chapter 4 Install Global Edition Regional configuration Figure 112 Database and file server paths ie Facility Commander Wnx 7 7 Setup ae zol x Global Database an
215. llation Manual 133 Chapter 4 Install Global Edition Regional configuration Select Regional Database Server and in the Select Global Database Server field select the Global database server for this Regional database server Figure 73 Create FCWnx database Select database server type fe Select Database Server Type EEE FCWnx Database Select the database installation option from the list below C This option will install a Global Database Server and COON PEE ENE Distributor SQL Server must already be installed with an instance of SPSQL rey This option will install the Regional Database Server One enna Paver i si client A Distributor must be selected from ist below Select Global Database Server GLOBAL32BIT SPSQL 2 Click Next The Create Convert Database window opens as shown in Figure 74 Ignore the sa User Name as displayed The Password field displays your previously assigned and encrypted SQL password If you purchased your Facility Commander Wnx system from UTC Fire amp Security a temporary password of SecurityMaster08 case sensitive was assigned for you Accept the password as displayed 134 FCWnx 7 7 Global Edition Installation Manual Chapter 4 Install Global Edition Regional configuration Figure 74 Create Convert Database Create Convert Database noe CI xf FCWnx 7 7 Database Collect login information To begin the database create convert process please supply the S
216. lobal configuration Figure 48 FCWnx Global Custom configuration File server and FCWnx client application i 7 Facility Commander Wnx 7 7 Setup FCWnx Global Custom Configuration Choose the appropriate components for a custom Global Edition installation 7 Click Next The Global Databases and FileServer Paths window opens as shown in Figure 49 on page 91 The Database Server Name field is available and required Select a server name from the drop down list of eligible SQL servers for this installation 90 FCWnx 7 7 Global Edition Installation Manual Chapter 3 Installing Facility Commander Wnx Global configuration Figure 49 Database server name required Facility Commander Wnx 7 7 Setup ai o xj Global Database and FileServer Paths O S Global Database Server Name Database Server Name Wise Installation Wizard lt Back Next gt Cancel 8 The File Server Name is a read only field and is unavailable for selection 9 Click Next to display the Change the Secure password window 10 The Facility Commander Wnx installation creates a new Windows User ID called secure By default the password is SecurityMaster08 case sensitive If your Windows network has security policies that enforce rules for password creation you may need to change the secure user password If you are unsure ask your system administrator Select one of the following on the Change the Secure password window e Use De
217. lobal configuration To install required components 1 Verify that the computer you are configuring meets minimum requirements 2 Insert the FCWnx installation disc into the CD DVD drive When prompted click Run autorun exe If the disc does not launch you must manually start the software Using Windows Explorer navigate to the FCWnx Installation disc and then double click autorun exe 3 The Facility Commander Wnx Main Menu opens Click Install FCWnx v7 7 4 The Facility Commander Wnx introduction page opens Click Install A series of windows may display as the listed components automatically install if not already there These components may cause the system to restart when a new version is installed If your computer restarts log on as Administrator and installation continues NET Framework e Windows Installer Note On rare occasions when installing Facility Commander from a DVD drive the installation will stall for approximately 10 to 20 minutes from the time you click Install to the time when the Welcome to Facility Commander Wnx 7 7 Installation Wizard page opens If this occurs it is most likely caused by your anti virus software If you have anti virus software running you must configure it so that the DVD drive is not scanned Refer to the documentation that came with your anti virus software for details 5 The Facility Commander Wnx installation processes updates on your system When the latest versions of e
218. m before attempting to license any Facility Commander Wnx application FCWnx 7 7 Global Edition Installation Manual 151 Chapter 4 Install Global Edition Regional configuration Figure 86 File server Name Required ie Facility Commander Wnx 7 7 Setup Global Database and FileServer Paths O i File Server Name Cn Wise Installation Wizard coos _ ee BAES x 3 Click Next to display the Logon Account for SQL Server Services window as shown in Figure 87 Note Each Server used in the Facility Commander Wnx Global Edition system requires the database services to run under a domain user name and password account This account must have administrative privileges to that particular computer We suggest that you use the identical domain account at each computer used in the UTC Fire amp Security system Enter the user domain and username in the format Domain Username or click Browse to navigate the Windows network and select Enter the domain user Password and then click Next 152 FCWnx 7 7 Global Edition Installation Manual Chapter 4 Install Global Edition Regional configuration Figure 87 Logon Account for SQL Server Services ie Facility Commander Wnx 7 7 Setup Logon Account fo L Server Services Enter the domain user account to be used by Microsoft SQL Server for replication Global Edition uses Microsoft SQL Serve
219. m configuration and displays the Facility Commander Wnx icon on your desktop This may take a few minutes 11 When the Facility Commander Wnx has been successfully installed window displays click Finish FCWnx 7 7 Global Edition Installation Manual 257 Chapter 8 Installing Facility Commander Wnx Software on additional clients 12 Continue with Licensing the client computer below Licensing the client computer Typically you are configuring computers that are running additional Facility Commander Wnx client applications The reminder to license is placed at this point to maintain the proper sequence in completing the installation At this time proceed to Chapter 6 License and Set Security Settings for your FCWnx System on page 225 Note Reminder When the licensing sequence is complete return to this step and continue the installation Setting services to automatic startup Now you need to change the startup method of the FCWnx services to automatic This means every time the computer starts the Facility Commander Wnx services start Refer to Facility Commander Wnx services overview on page 266 for additional information about Facility Commander Wnx Services Note At this point in the installation the Facility Commander Wnx services are stopped Only Global database server installation No services are installed at this point if this is a custom installation and Facility Commander Wnx client application
220. m the network administrator or use a local IP address that no other computer is using in your network Consult your network administrator for detailed instructions FCWnx 7 7 Global Edition Installation Manual 243 Chapter 7 Windows 7 Vista and XP Professional system setup 7 Click OK 8 Click OK to exit Local Area Connection Properties 9 After Windows is installed restart the computer and make sure it is connected to the network Verify that you do not have any hardware errors under Device Manager Windows Vista and Windows 7 To check the network settings 1 Click Start and then click Control Panel Category view Click Network and Internet and then click Network Sharing Center Classic view Double click Network Sharing Center Click Manage network connections 3 Right click the Local Area Connection and then select Properties The Local 4 Area Connection Properties window opens Select Internet Protocol Version 4 TCP IPv4 and Version 6 TCP IPv6 Note If Version 6 is enabled on the server it must be enabled on the client 5 6 7 8 Click Properties Select one e Obtain an IP address automatically e Use the following IP address Note Facility Commander Wnx computers do not require static IP addresses However if you selected Use the following IP address option you must obtain a valid IP address from the network administrator or use a local IP address that no other computer i
221. mander Wnx client software in English As more languages are installed more language specific folders display A shared empty shared folder created to store reports created by third party report generator A shared folder that contains the firmware or application code needed to flash the controllers FCWnx 7 7 Global Edition Installation Manual 191 Chapter 4 Install Global Edition Regional configuration gmcNls A folder that contains the language support files for the GMC application After the base install of FCWnx these folders are empty as no language kits have been installed yet As the language kits are installed the language support files are placed in this folder GraphicsCache A shared folder that contains the working data files for the GMC application Logs A shared folder that contains the Facility Commander Wnx diagnostic log files Rpt A folder that contains files used by the report engine to create Facility Commander Wnx reports SecureScripts The scripts and programs used to create the database in SQL Server It also contains subfolders required for converting and upgrading to Facility Commander Wnx UserManuals A folder that contains the FCWnx and GMC User Manuals in pdf format Video An empty shared folder created to store video files and JPG image files grabbed from video windows VideoSubsystem A folder that contains the dlls that enable communication between FCWnx and VMC Vmc A folder that contains
222. mode on page 229 for details This scenario assumes that this is the first client and this client is licensing some time AFTER the Facility Commander Wnx installation sequence To license after installation of Facility Commander Wnx 1 Click Start Programs Facility Commander Wnx FCWnx License The License Setup page opens 1 Check the check box First Time License 2 SQL Password for FCWnx Enter a 12 digit password that the application will use to access the FCWnx database By default it is set to the first 12 characters of the Machine Seed Key 230 FCWnx 7 7 Global Edition Installation Manual 3 Chapter 6 License and Set Security Settings for your FCWnx System Select the Warranty Reminder in the Days before Expiration group box and enter or select the number of days before expiration of your warranty that you want a reminder to begin displaying in your application This field accepts a number between 0 and 120 License controller 4 Accept and do not change the License Controller Machine Seed Key as displayed 5 In the License Key sections enter the 35 character license key string obtained through the UTC Fire amp Security Web site You can type the entry into the control dialog boxes or copy cut and then click any License Key control dialog box to paste the entire key File Server 6 The Path for license information file located on the File Server is a read only dialog box and displays for informat
223. mputer File server and FCWnx client application on second computer Note Prerequisite database server installation is already complete 1 2 Verify that the computer you are configuring meets minimum requirements If not already done install the Windows 2003 or Windows 2008 operating system but do not install Microsoft SQL You must be logged in as administrator user to the domain If not log off and log back on as a user with administrator permissions Insert the Facility Commander Wnx installation disc into the CD DVD drive 5 When the AutoPlay window opens click Run SETUP EXE 6 When Facility Commander Wnx starts click Install If the disc does not 168 launch you must manually start the software Using Windows Explorer navigate to the FCWnx Installation disc and double click Setup exe A series of windows open as the listed components install Answer the prompts as appropriate and continue This takes several minutes e NET Framework e Windows Installer Installing non English operating systems FCWnx 7 7 Global Edition Installation Manual Chapter 4 Install Global Edition Regional configuration During installation the installation process checks your system for minimum required components If the following Microsoft Windows components are not detected installation is halted e NET Framework A popup message opens informing you that installation will be cancelled until you install the required s
224. n Manual 139 Chapter 4 Install Global Edition Regional configuration Figure 78 Logon account for SQL server services 4 6 140 fe Facility Commander Wnx 7 7 Setup Logon Account for SQL Server Service Enter the domain user account to be used by Microsoft SQL Server for replication Global Edition uses Microsoft SQL Server Replication technology Pepica requires that SOL Server Services are running using a domain user account that has administrator privileges on both the local machine and also on the other FCOWnx database servers that are part of the Global Edition installation The domain and user name should be entered with the following format Domain UsemName For example SPDomain Secure Domain U ser Name Browse Password Wise Installation Wizard Enter the user domain and username in the format Domain Username or click Browse to navigate the Windows network and select Enter the domain user password in the Password field Click Next The Change the Secure password window opens The Facility Commander Wnx installation creates a new Windows User ID called secure By default the password is SecurityMaster08 case sensitive If your Windows network has security policies that enforce rules for password creation you may need to change the secure user password If you are unsure ask your system administrator Select one of the following on the Change the Secure password w
225. n and browse to the folder location where database log files will be stored Note This refers to the database logs this does NOT refer to the Facility Commander Wnx logs FCWnx 7 7 Global Edition Installation Manual 117 Chapter 3 Installing Facility Commander Wnx Global configuration Figure 65 Create Database Initialize the database creation 6 Create Database FCWhnx 7 7 Database Initialize the database creation Q View Error Log m Database Directory EE oe a TMM View Integrity Report cto __ oee Click Create Database The database creation begins and a progress bar is displayed This may take a few minutes Caution If a database already exists a warning message will display stating that you are about to overwrite your existing database with an empty default database Order of events Global database server database creation For information only this is the order of events taking place during the Global Database creation No action is required on the part of the user Table 13 Order of Events Global database server database creation Step Description 1 118 The Global database server databases are created SecurePerfect SecurePerfectHistory and SecurePerfectArchive The SecurePerfectDistributor database is installed and enabled The Global database server is configured for publishing The Publisher is identified by the Global database instance name In thi
226. n installation Regional There can be several of these for an FC Wnx Global Edition installet IV File Server Choosing this option will install the FCwnx File Server components I FCWnx Client Application rs Choosing this option vall install the FCWnx Client Application Wise Installation Wizard Cen 138 FCWnx 7 7 Global Edition Installation Manual Chapter 4 Install Global Edition Regional configuration 2 Click Next The Global Database and FileServer Paths window opens as shown in Figure 77 Select a Global Database Server Name from the drop down list of Servers in this domain The Database Server Name and File Server Name are unavailable for input Click Next Figure 77 Global Database and FileServer Paths i Facility Commander Wnx 7 7 Setup aS Tl RS Global Database and FileServer Paths O O Global Database Server Name REGIONAL32BINSPSQ File Server Name REGIONAL32BIT Wise Installation Wizard ne 5 3 The Logon Account for SQL Server Services window opens as shown in Figure Figure 78 Note Each server used in the Facility Commander Wnx Global Edition system requires the database services to run under a domain user name and password account This account must have administrative privileges to that particular computer We suggest that you use the identical domain account at each computer used in the UTC Fire amp Security system FCWnx 7 7 Global Edition Installatio
227. n on Windows 2008 with SQL 2008 For Windows 2008 Server SQL Server 2008 systems you must install the Distributed File System prior to configuring file replication Refer to Windows Server 2008 Distributed File System on page 36 Distributed File System is implemented as a role service of the File Services role Distributed File System consists of two role services e DFS Namespaces e DFS Replication DFS Namespaces enables you to group shared folders that are located on different servers into one or more logically structured namespaces DFS Replication is a multiple master replication engine that can replicate data between multiple servers over limited bandwidth network connections Verifying Distributed File System service is started Before you continue verify that the Distributed File System service is started To verify the Distributed File System service is started 1 Click Start Settings Control Panel and then double click Administrative Tools Double click Services The Services window opens 2 Select DFS Namespace service 3 The status will be either Started or blank If it is blank then the service is not running and needs to be started 4 Right click and select Properties In the Startup type field select Automatic 5 Click Start to start the service 6 Click Apply and then OK to close the window 7 Repeat Steps 2 through 5 for DFS Replication service 8 Close the Services window FCWnx 7 7 Gl
228. nabled in the Firewall Exceptions list e File and Printer Sharing e Network discovery e Workgroup Only Remote Administration To enable Firewall Exceptions selections 1 Click Start and then click Control Panel 2 On the control panel click Security Center and then click Windows Firewall 3 On the left pane click Allow a program or feature through Windows Firewall 4 On the Allow programs to communicate through Windows Firewall page make sure that the following check boxes are checked and then click OK e File and Printer Sharing e Network discovery e Workgroup Only Remote Administration The Remote Administration selection is not available in Windows 7 by default Refer to your Window 7 documentation for details on enabling this selection What s next You are ready to install Facility Commander Wnx Refer to Chapter 8 Installing Facility Commander Wnx Software on additional clients on page 249 248 FCWnx 7 7 Global Edition Installation Manual Chapter 8 Installing Facility Commander Wnx Software on additional clients Summary This chapter includes instructions for installation and configuration of Facility Commander Wnx on additional client computers These computers can be communication clients for hosting controllers and digital video recorders and available as Imaging stations Follow instructions in the order presented Content Defining additional clients 250 Reaching the First Time Licens
229. nal selection determines if you are installing Facility Commander Wnx on e Global server computer must have SQL Server already installed There can be only one Global database server Select this option e Regional server computer This is the default You are not installing a Regional server computer at this time e File server Only Facility Commander Wnx file server components install This server stores the data files shared by clients on the Facility Commander Wnx network File shares include graphics images signatures designs video and firmware The File Server option is a prerequisite in order to install FCWnx Client Application e FCWhnx Client Application Only the FCWnx Client application installs Only FCWnx client file shares install This includes the executable file Facility Commander Wnx services and Facility Commander Wnx DLLs FCWnx 7 7 Global Edition Installation Manual Chapter 3 Installing Facility Commander Wnx Global configuration e Install to Windows Server Cluster Group Named If you are setting up a cluster environment contact Technical Support for assistance 5 Continue with Custom configuration options below Custom configuration options Caution This procedure is recommended for experienced software installers only The scenarios presented in the custom configurations that follow are the result of selections made on the FCWnx Global Custom Configuration window Review Figure 22 on page
230. nced users Wise Installation Wizard 4 Click Next Proceed to CUSTOM Installation Facility Commander Wnx Global database server below CUSTOM Installation Facility Commander Wnx Global database server Caution This procedure is recommended for experienced software installers only Note Installation of Global database server and Regional database servers follow a similar set of instructions Verify that you are installing a Global database server before you begin You must select Custom in order to do any of the following e Install Global Edition features e Select Credential aliasing e Change the password for the Window logon USERID secure e Selectively install database server File Server or FCWnx Client Application These configuration options allow Facility Commander Wnx databases and file shares to be separated from Facility Commander Wnx application code and placed on another computer defined by you 48 FCWnx 7 7 Global Edition Installation Manual Chapter 3 Installing Facility Commander Wnx Global configuration To begin your custom installation 1 The Installing Global Edition window opens If this window does not display this computer is not a member of a domain You must be part of a domain to continue 2 When asked Is this computer part of an FCWnx Global Edition installation select Yes and click Next Figure 21 Installing Global Edition window F Facility Commander
231. nder Wnx To add yourself as an operator in Facility Commander Wnx 1 When you log on change the password of the default login ID secure 2 Add yourself as an operator in Facility Commander Wnx This will allow Facility Commander Wnx to track you and the steps you take in setting up the system To add yourself as an operator select Administration from the Application Group pane and then Operator For detailed instructions to configure an operator record refer to the Facility Commander Wnx 7 7 User Manual or the Facility Commander Wnx Help System 3 Log off and then log on as the new operator Initial setup of Facility Commander Wnx records Refer to the Facility Commander Wnx Help System as a guideline in setting up your system records The steps follow a specific sequence that is suitable for a smooth system configuration Setting e mail accounts Configuring e mail accounts can be accomplished by selecting Administration from the Application Group pane and then Preference On the Settings tab select Enable in the Alarm Notifier E mail Support section This capability allows you to notify an e mail account when incoming Facility Commander Wnx alarms are received Refer to the Facility Commander Wnx Help System for details of this option FCWnx 7 7 Global Edition Installation Manual 271 Chapter 9 Logging on and configuring Facility Commander Wnx Changing the Facility Commander Wnx server computer name This section is
232. nfiguration Figure 113 FCWnx component services File Action View Help leo i asihm gt au FCWnx Diagnostics Name Description Status Startup Type Log On As z Gh Encrypting File System EFS Provides the core file encrypti Manual Local System G Extensible Authentication Protocol The Extensible Authentication Manual Local System S Fax Enables you to send and recei Manual Network Service s FCWnx API Service Provides COM API for use by Local System Stop the service Restart the service Description Provides logging support for FCWnx services and applications agnost rovides logging support fo cal System 1 FCWnx Diagne p tfor Local Systerr Sh FCWnx Manager Manages FCWnx physical and Local System GA FCWnx Media Server Provides video device services Local System Gh FCWnx System Manager Manages FCWnx low level int Local System Sh FCWnx WebService Provides web service API for u Local System Sh FCWnxWCF Service Provides WCF API for use by F Local System 4 w Extended Standard 2 Select FCWnx Diagnostics The status will be either Started or blank If it is blank then the service is not running 4 Right click and then select Properties In the Startup type field select Automatic Click Apply and then OK to close the window Repeat steps 3 through 6 for the following services FCWnx Manager FCWnx Media Server FCWnx System Manager
233. ng click Stop under Service status 6 Select and display the Log On tab 7 Select This account The field for account name is now enabled FCWnx 7 7 Global Edition Installation Manual 45 Chapter 3 Installing Facility Commander Wnx Global configuration 8 Enter the name of the domain account that will start and stop SQL services or click Browse to navigate the Windows network and select the name of the domain account 9 Enter the password for the domain account and then enter the password again to confirm 10 Return to the General tab and verify that Startup type is set to Automatic 11 Click Start under Service status 12 Click OK to accept and close the window 13 From the list of Local Services select SQL Server Agent SPSQL and then right click to display the shortcut menu 14 Repeat step 3 through step 11 Installation Before you begin e Your Facility Commander Wnx system will not install unless minimum requirements have been met Before you begin refer to Recommended minimum requirements on page 2 and Preinstallation checklist on page 44 e If you are installing on a non English operating system NET Framework must be installed in the appropriate language to the operating system you are installing You cannot install Facility Commander Wnx until this is accomplished Starting the installation To install required components 1 You must be logged in as an administrator to the domain If not
234. ng FCWnx If the uninstall does not proceed hangs follow the instructions below 294 FCWnx 7 7 Global Edition Installation Manual Chapter 13 Troubleshooting maintenance support To uninstall FCWnx 1 Click Ctrl Alt Delete The Windows Security dialog opens Click Task Manager At the Task Manager window Install displays a status of Not Responding Select the line Uninstall and click End Task At the next dialog click End Task again a Or TO ee ee Once the steps above are completed continue with the next section Verifying and cleaning up after an uninstall below Verifying and cleaning up after an uninstall You may encounter problems while uninstalling from a server computer Sometimes this results in an incomplete uninstall which means miscellaneous files are left behind If you did encounter problems the sections that follow detail some troubleshooting steps to assist you in troubleshooting your uninstall The first step is to verify that Facility Commander Wnx uninstalled cleanly Refer to Verifying FCWnx uninstalled cleanly below Verifying FCWnx uninstalled cleanly Check the Facility Commander Wnx folder and verify that the Database and Logs folders are the only items left To verify a Facility Commander Wnx uninstall 1 Go to Windows Explorer and navigate to your Facility Commander Wnx folder The default setting is Program Files GE FCWnx 2 You should see the Database and Logs folders only
235. ng FCWnx alarms to CCTV alarms on page 337 Adding changing or deleting CCTV alarms CCTV alarms are the actual messages that are sent out to the Kalatel interface They control what sequence of monitors and cameras are switched on and off The Kalatel controller is preprogrammed to interpret these messages To Appendix C CCTV Interfaces program the Kalatel controller refer to the manual on the Kalatel command console language To add CCTV alarms within FCWnx 1 From the FCWnx Application Group pane select Gateways amp Interfaces then CCTV Interface 2 Click Add 3 Inthe Description field enter the appropriate description for your system Example Kalatel CCTV Alarm 4 Inthe CCTV Interface field choose Kalatel 5 Inthe CCTV Alarm field choose the alarm number of the interface you are monitoring 6 The Enable Message and Disable Message fields are automatically filled Use these default settings 7 Inthe Reset CCTV Alarm field two reset choices for the alarm are provided when the alarm is cleared from the Alarm Monitor or when the alarm Resets This means the Reset or the disable message can be sent out when the FCWnx alarm ls cleared from the Alarm Monitor e Resets 8 Click Save To change CCTV alarms within FCWnx 1 From the FCWnx Application Group pane select Gateways amp Interfaces then CCTV Interface 2 Click Search 3 In the Search Result window locate and then select the
236. ng to at least the following local groups e Users e Power Users e SPAdmin These groups grant the Windows user access to the Imaging system registry keys and file system To add an operator to user groups 1 Click Start and then click Control Panel Category view Click Performance Maintenance Administrative Tools and then click Computer Management Classic view Click Administrative Tools and then click Computer Management The Services window displays Expand the list of services and scroll down Select Local Users and Groups then Users Your window should look similar to Figure 152 Figure 152 Imaging login setup Computer Management E 0 x l Action view gt am ABe Tree Computer Management Local i ic i System Tools Built in account For quest access to the computer domain E E Event Viewer secure Secure Perfect Default User E g System Information wee SQLAGentCmdExec SQL Server Agent CmdExec Job Step Account j gl Performance Logs and Alerts Shared Folders a Device Manager Local Users and Groups Sy Users E Groups Sy Storage Disk Management Be Disk Defragmenter Logical Drives El 2 Removable Storage a T Services and Applications 4 Double click the user login Name to which you are adding access to login groups The user Properties window displays 5 Select the Member Of tab then click Add 262 FCWnx 7 7 Global Edition Installation Manual C
237. nline Help for addition information about the Integrity utility Click OK The dialog box closes If you receive a message to restart at this time click Yes to restart log on and continue 8 An FCWnx License Setup window opens Unless otherwise stated in your configuration scenario proceed to Licensing your Facility Commander Wnx system on page 187 FCWnx 7 7 Global Edition Installation Manual 137 Chapter 4 Install Global Edition Regional configuration Database server and file server configuration Components Computer 1 Computer 2 Computer 3 Database server v File server v FCWnx client application v Note This configuration has the database server and the file server installed on Computer 1 then the FCWnx client application is installed on Computer 2 Database server and file server on first computer To install the database server and file server on the first computer 1 On the FCWnx Global Custom Configuration window select Database Server Regional and File Server See Figure 76 Figure 76 FCWnx Global custom configuration database server and file server fe Facility Commander Wnx 7 7 Setup ioj x FCVvnx Global Custom Configuration aS Choose the appropriate components for a custom Global Edition installation a IV Database Server Choosing this option will install the FCW nx database components Please select which type of server C Global Only one of these per FCWnx Global Editio
238. nsider this if your IT Department has certain policies regarding database installation Consult with your IT Department for assistance Data File directory The Data File Directory field displays the default directory Accept the default as displayed or click the Browse button and browse to any folder location where data files will be stored Note If you are installing in a Cluster configuration the Distributor installs to the same path as the Cluster Data File directory Log File directory The Log File Directory field displays the default directory Accept the default or click the Browse button and browse to the folder location where database log files will be stored Note This refers to the database logs this does NOT refer to the Facility Commander Wnx logs FCWnx 7 7 Global Edition Installation Manual Chapter 3 Installing Facility Commander Wnx Global configuration Figure 30 Create Database Initialize the database creation fe create Database T FCWhnx 7 7 Database Initialize the database creation Q View Error Log m Database Directory r area a I TMM GE FCWnx Database m Log File Directory C Program Files GE FCWnx Database at View Integrity Report cok e gt ooe 5 Click Create Database The database creation begins and a progress bar is displayed This may take a few minutes Caution If a database already exists a warning message will display stating that you ar
239. nstall Global Edition Regional configuration Before you begin Your Facility Commander Wnx system will not install unless minimum requirements have been met Before you begin refer to Recommended minimum requirements on page 2 and Preinstallation checklist on page 44 If you are installing on a non English operating system NET Framework must be installed in the appropriate language to the operating system you are installing You cannot install Facility Commander Wnx until this is accomplished Installation Starting the installation To install required components 1 You must be logged in as an administrator to the domain If not log off and then log back in as an administrator to the domain Insert the FCWnx installation disc into the CD DVD drive When prompted click Run autorun exe If the disc does not launch you must manually start the software Using Windows Explorer navigate to the FCWnx Installation disc and then double click autorun exe 3 The Facility Commander Wnx Main Menu opens Click Install FCWnx v7 7 4 The Facility Commander Wnx introduction page opens Click Install 124 A series of windows may display as the listed components automatically install if not already there These components may cause the system to restart when a new version is installed If your computer restarts log on as Administrator and installation continues e NET Framework e Windows Installer Note On r
240. nstallation The following history tables are contained within AlarmHistoryTable BadgeHistoryTable DlHistory DOHistory DVMRHistory GuardTourHistory OperatorHistoryTable SecureAreaHistory ZoneHistoryTable 6 A message opens FCWnx Database successfully created Note A log file is created when the Create Database program is run The log file called CreateDatabaseLog is found in the Logs folder The Integrity utility runs automatically following a database creation No user interaction is required Refer to your Facility Commander Wnx Online Help for addition information about the Integrity utility 7 Click OK The dialog box closes If you receive a message to restart at this time click Yes to restart log on and continue 9 An FCWnx License Setup window opens Unless otherwise stated in your configuration scenario proceed to Licensing your Facility Commander Wnx system on page 108 Note Be sure to complete all instructions for the scenario you are installing File server on second computer Now you must select and install only the file server component on a separate Windows 2003 or 2008 Standard server computer Note Prerequisite database server and FCWnx client application installation already complete If you do not install the file server at this time you will not be able to license your system 100 FCWnx 7 7 Global Edition Installation Manual Chapter 3 Installing Facility Commander Wnx G
241. nstallation Manual 59 Chapter 3 Installing Facility Commander Wnx Global configuration 9 Enter your new password and then enter a second time 10 Click Next The Ready to Install the Application window opens 11 Enter the SQL Server password for the sa user This password was previously created during installation of SQL Refer to Installing Microsoft SQL Server on page 17 12 The default Destination Folder is indicated You may want to install to another location Click Browse to navigate to the program folder of your choice for placement of Facility Commander Wnx files 13 Click Next to continue Facility Commander Wnx copies system files updates the system configuration and displays the Facility Commander Wnx icon on your desktop This may take a few minutes 14 When the Facility Commander Wnx has been successfully installed window opens click Finish 15 If your computer restarts log on and continue Creating the database custom installation To install the Global database server 1 A Select Database Server Type window opens as shown in Figure 28 on page 61 Select Global Database Server and click Next 60 FCWnx 7 7 Global Edition Installation Manual Chapter 3 Installing Facility Commander Wnx Global configuration Figure 28 Create FCWnx database Select database server type Select Database Server Type FREES FCWnx Database Select the database installation option from the l
242. nstalled e NET Framework e Windows Installer If your computer restarts log on as administrator and installation continues The Facility Commander Wnx installation processes updates on your system When the latest versions of each component are updated and identified Facility Commander Wnx installation begins and the Welcome window opens Continue with Facility Commander Wnx software installation begins below Facility Commander Wnx software installation begins Note A Cancel button displays on every FCWnx installation window If you click Cancel at any time during the installation the FCWnx installation process stops but all Windows components that have been installed must be manually removed To install the FCWnx client application on the second computer 1 The Facility Commander Wnx Welcome window opens Click Next The License Agreement window opens 2 Select accept the license agreement and then click Next 3 The Select Installation Type window opens as shown in Figure 82 Select the 146 type of installation as Custom FCWnx 7 7 Global Edition Installation Manual Chapter 4 Install Global Edition Regional configuration Figure 82 Select Installation type Custom Select installation Type Select the desired installation type Typical The most common application features will be installed This option a le is recommended for most users Custom amp Use this op
243. nts at the server computer e Custom Installation The file components required to license may be stored on two separate computers e The file server stores the Licenselnfo file The First Time License computer stores the Facility Commander Wnx Component Services files Note You must be able to reach the computer s for both sources Pinging the First Time License computer To communicate with the First Time License computer by computer name 1 Click Start then Run 2 Type cmd then click OK A command prompt window opens 3 Type ping lt servername gt where lt servername gt is the name of the First Time License computer Press Enter 250 FCWnx 7 7 Global Edition Installation Manual Chapter 8 Installing Facility Commander Wnx Software on additional clients Successful A successful ping reveals the computer address was reached Your window should look similar to Figure 146 below Proceed to install Facility Commander Wnx on the client computer Refer to If you are installing on a non English operating system NET Framework must be installed in the appropriate language to the operating system you are installing You cannot install Facility Commander Wnx until this is accomplished Starting the installation on page 253 Figure 146 Successful ping to server computer 3 WINNT System32 cmd exe iC gt ping BCTBOGOTA Pinging BCTBOGOTA 3 18 145 104 with 32 bytes of data Reply from 3 18 145 10 4 bytes 32
244. nts automatically install if not already there These components may cause the system to restart when a new version is installed If your computer restarts log on as Administrator and installation continues e NET Framework e Windows Installer Note On rare occasions when installing Facility Commander from a DVD drive the installation will stall for approximately 10 to 20 minutes from the time you click Install to the time when the Welcome to Facility Commander Wnx 7 7 Installation Wizard page opens If this occurs it is most likely caused by your anti virus software If you have anti virus software running you must configure it so that the DVD drive is not scanned Refer to the documentation that came with your anti virus software for details The Facility Commander Wnx installation processes updates on your system When the latest versions of each component are updated and identified Facility Commander Wnx installation begins and the Welcome window opens Continue with Facility Commander Wnx software installation begins below Facility Commander Wnx software installation begins Note A Cancel button displays on every FCWnx installation window If you click Cancel at any time during the installation the FCWnx installation process stops but all Windows components that have been installed must be manually removed To install the file server on the second computer 1 2 The Facility Commander Wnx Welcome window opens
245. nual Chapter 4 Install Global Edition Regional configuration Figure 89 Create FCWnx database Select database server type Select Database Server Type d Efe x FCWnx Database Select the database installation option from the list below Global Database Server This option will install a Global Database Server and Distributor SQL Server must already be installed with an instance of SPSQL A z This option will install the Regional Database Server Regional Database Server on a local client A Distributor must be selected from ist below Select Global Database Server GLOBAL32BIT SPSQL 2 Click Next The Create Convert Database window opens as shown in Figure 90 Ignore the sa User Name as displayed The Password field displays your previously assigned and encrypted SQL password If you purchased your Facility Commander Wnx system from UTC Fire amp Security a temporary password of SecurityMaster08 case sensitive was assigned for you Accept the password as displayed FCWnx 7 7 Global Edition Installation Manual 155 Chapter 4 Install Global Edition Regional configuration Figure 90 Create Convert Database 3 156 Create Convert Database FCWnx 7 7 Database Collect login information To begin the database create convert process please supply the SQL Server SQL 2008 Express administrators username and password in the following text box es Click Next The Create
246. nual Chapter 5 Configuring Global Edition for file replication Figure 134 DFS Management File Action View Window Help gt Alm le id DFS Management A B Namespaces disneyworld com publicbuilding bs GLOBAL32BIT Namespacel Stand alone namespace Namespace Namespace Servers Delegation Search New Folder entries SS a El Y Replication LaS amp Designs np Peer F global New Window from Here Delete Refresh Properties Help 2 Right click on the namespace and then click New Folder The New Folder page opens as shown in Figure 135 Enter the name of one of the FCWnx shared folders such as Firmware in the Name field and then click Add FCWnx 7 7 Global Edition Installation Manual 215 Chapter 5 Configuring Global Edition for file replication Figure 135 Namespace New Folder pio erscemen h 3 The Add Folder Target page opens Click Browse to select your Global Server shared folders as shown in Figure 136 and then select the appropriate folder Click OK Figure 136 Browse for Shared Folders Browse for Shared Folders F d __ Show Shared Folders Designs Extemals Licenselnfo Logs Namespace publicbuilding Replication Video 216 FCWnx 7 7 Global Edition Installation Manual Chapter 5 Configuring Global Edition for file replication 4 The Add Folder
247. nx 7 7 has been successfully installed window opens click Finish 14 If your computer restarts log on and continue Creating the database custom installation To create the database 1 A Select Database Server Type window opens as shown in Figure 25 on page 55 Select Global Database Server and click Next The Create Convert Database window opens 54 FCWnx 7 7 Global Edition Installation Manual Chapter 3 Installing Facility Commander Wnx Global configuration Figure 25 Create FCWnx database Select database server type 2 Select Database Server Type FCWnx Database Select the database installation option from the list below re 215 x Cy SAE nae This option will install a Global Database Server and aca aj Distributor SAL Server must already be installed with an instance of SPSQL s This option will install the Regional Database Server C Regional Database Server n prad client A Distributor must be selected from ist below Select Global Database Server Cancel Ignore the sa User Name as displayed The Password field displays your previously assigned and encrypted SQL password If you purchased your Facility Commander Wnx system from UTC Fire amp Security a temporary password of SecurityMaster08 case sensitive was assigned for you Accept the password as displayed Click Next The Create Database Initialize the Database Creation window opens Each Facility
248. nx Server Name Definition window 138 FCWnx Server Name Definition i xi Your current FCWnx Server is GLOBALSERVER Please enter the name of the computer which will be used as the new FCWnx Server PC NEWG LOBALSERVER Cancel Your EXISTING server computer name displays as a read only field Ignore this field Enter the NEW server computer name in the appropriate field 6 Click OK A Server Name Definition dialog box displays an update message similar to the following Figure 158 Server Name Definition Update message Server Name Definition E x A New Server Name NEWGLOBALSERVER is updated Please RELICENSE this computer 7 Click OK to close this window 9 Relicense your Facility Commander Wnx system at this time If the computer has NOT changed just the computer name you can use your existing license key provided at the time you purchased your system If the computer has changed your system needs to be relicensed with a NEW license key Be prepared to obtain a new license from UTC Fire amp Security Refer to Generating a registration key on page 227 Click OK 10 Proceed to change the server computer name on all clients in your Facility 274 Commander Wnx system repeating the steps beginning with Server Computer Name in System Properties on page 272 FCWnx 7 7 Global Edition Installation Manual Chapter 9 Logging on and configuring Facility Commander Wnx No
249. o Logs Namespace 11 Replication Video Fl E New Shared Folder Cancel FCWnx 7 7 Global Edition Installation Manual 219 Chapter 5 Configuring Global Edition for file replication 10 The New Folder Target page opens with the Path to folder target field populated Click OK 11 The Replication dialog opens Click Yes to create a replication group 12 The Replication Group and Replicated Folder Name page opens Click Next 13 The Replication Elgibility page opens Click Next 14 Select the Global Server as the Primary Server from the drop down and then click Next 15 The Topology page opens Make sure the Full mesh radio button is selected and then click Next 16 The Replication Group Schedule and Bandwidth page opens Click Next 17 The Confirmation page opens stating that you have successfully completed the Replicate Folder Wizard Click Close 18 The DFS Management page opens Repeat steps 2 through 17 for the remaining shared folders e Designs e Externals e Firmware e Video Adding additional clients to the database Pinging additional client computers In order to add an additional client computer in the database you must verify that the computer can be reached by name To reach the client computer 1 Click Start then Run 2 Type cmd then click OK A command prompt window opens 3 Type ping lt name gt where lt name gt is
250. o restart when a new version is installed e NET Framework e Windows Installer If your computer restarts log on as administrator and installation continues The Facility Commander Wnx installation processes updates on your system When the latest versions of each component are updated and identified Facility Commander Wnx installation begins and the Welcome window opens Continue with Facility Commander Wnx software installation begins on page 66 Facility Commander Wnx software installation begins Note A Cancel button displays on every FCWnx installation window If you click Cancel at any time during the installation the FCWnx installation process stops but all Windows components that have been installed must be manually removed To install the FCWnx client application on the third computer The Facility Commander Wnx Welcome window opens Click Next The License Agreement window opens Select accept the license agreement and then click Next 3 The Select Installation Type window opens as shown in Figure 110 Select the type of installation as Custom FCWnx 7 7 Global Edition Installation Manual 183 Chapter 4 Install Global Edition Regional configuration Figure 110 Select Installation type Custom Select installation Type Select the desired installation type Typical x E Oo 7a Custom x Els zf sw Wise Installation Wizard The most common application features wi
251. o the information stored in these folders when logged in as an authorized user 190 FCWnx 7 7 Global Edition Installation Manual Chapter 4 Install Global Edition Regional configuration Figure 114 Typical server folder structure GE ar oo FF m GE File Edit View Tools Help j Views m Explore az Share v Date modified AT 7 28 2010 9 48 AM_ File Folder l0 x Organize v Name FCWnx Favorite Links E Documents E Pictures FP Music More Folders M E a FCWnx aj di Config Database im Designs Jb English me Externals fey Firmware P gmcNis GraphiesCache midi ire imp Logs ie Rot El di SecureScripts amp UserManuals im Video Ji VideoSubsystem m Ji vmc J vma d WebService ps E a This is a description of the folders in your Facility Commander Wnx directory Table 20 Server folder descriptions Folder name Description Config Database Designs English Externals Firmware A folder that contains website configurations for the FCWnx Web Service The FCWnx Web Service is used by VMC to communicate with FCWnx A folder that contains the system database file along with the archive and history database files SQL Server log files for each database are also found in this folder A shared folder that contains all credential designs used by the imaging stations and sample credential designs The files required to display the Facility Com
252. o the information stored in these folders when logged in as an authorized user Figure 61 Typical server folder structure ma cinixl vay 3 Gore Bile File Edit View Tools Help Organize v j2 Views m lExplore az Share Name v Date modified iT Favorite Links FCWnx 7 28 2010 9 48 AM_ File Folder E Documents FE Pictures IB music More Folders M J FCWnx aj Wb Config Database i Designs ib English mg Externals mh Firmware P gmcNis o B GraphicsCache i ire Ry Logs Db Rot a J SecureScripts d UserManuals m Video J VideoSubsystem P vmc he ven B WebService gt gt f FCWnx 7 7 Global Edition Installation Manual 111 Chapter 3 Installing Facility Commander Wnx Global configuration This is a description of the folders in your Facility Commander Wnx directory Table 12 Server folder descriptions Folder name Description Config Database Designs English Externals Firmware gmcNls GraphicsCache Logs Rpt SecureScripts UserManuals Video VideoSubsystem Vmc vmcNls A folder that contains website configurations for the FCWnx Web Service The FCWnx Web Service is used by VMC to communicate with FCWnx A folder that contains the system database file along with the archive and history database files SQL Server log files for each database are also found in
253. obal Edition system requires the database services to run under a domain user name and password account This account must have administrative privileges to that particular computer We suggest that you use the identical domain account at each computer used in the UTC Fire amp Security system FCWnx 7 7 Global Edition Installation Manual Chapter 4 Install Global Edition Regional configuration Enter the user domain and username in the format Domain Username or click Browse to navigate the Windows network and select Enter the domain user password in the Password field Figure 105 Logon account for SQL server services i Facility Commander Wnx 7 7 Setup fe ol xi Logon Account for SQL Server Services Enter the domain user account to be used by Microsoft SOL Server for replication Global Edition uses Microsoft SQL Server Replication technology Replication requires that SOL Server Services are running using a domain user account that has administrator privileges on both the local machine and also on the other FOWnx database servers that are part of the Global Edition installation The domain and user name should be entered vath the following format Domain UserN ame For example SPDomain Secure Domain U ser Name Password Wise Installation Wizard 4 Click Next to display the Change the Secure password window opens The Facility Commander Wnx installation creates a new Windows User ID called secu
254. obal Edition Installation Manual 213 Chapter 5 Configuring Global Edition for file replication Configuring the DFS namespace 1 Click Start Settings Control Panel and then double click Administrative Tools Double click DFS Management The DFS Management window opens If a namespace is already configured continue with Configuring DFS file replication below If a namespace is not configured continue with To configure a namespace To configure a namespace 1 From the DFS Management window click Namespace From the toolbar click Action and then New Namespace The new Namespace Wizard opens 2 Enter your Global Server name or click Browse to find it Click Next 3 The Namespace Name and Settings page opens Enter a name for the namespace and then click Next The Namespace Type page opens Make sure the Domain based namespace radio button is selected and then click Next 5 The Review Settings and Create Namespace page opens Click Create 6 A confirmation page opens once the namespace is created Click OK to exit the wizard Configuring DFS file replication The following shared folders must be configured for DSF file replication 1 214 e Designs e Externals e Firmware e Video Click Start Settings Control Panel and then double click Administrative Tools Double click DFS Management The DFS Management window opens as shown in Figure 134 FCWnx 7 7 Global Edition Installation Ma
255. oft SQL Server on page 17 14 The default Destination Folder is indicated You may want to install to another location Click Browse to navigate to the program folder of your choice for placement of Facility Commander Wnx files 15 Click Next to continue Facility Commander Wnx copies system files and updates the system configuration This may take a few minutes 16 When the Facility Commander Wnx has been successfully installed window opens click Finish 17 Remove the FCWnx Installation disc from the CD DVD drive 18 If your computer restarts log on and continue Creating the database custom installation Order of events Global database server database creation To create the database 1 A Select Database Server Type window opens as shown in Figure 44 on page 84 Select Global Database Server and click Next FCWnx 7 7 Global Edition Installation Manual 83 Chapter 3 Installing Facility Commander Wnx Global configuration Figure 44 Create FCWnx database Select database server type Select Database Server Type FCWnx Database Select the database installation option from the list below ta A This option will install a Global Database Server and Global Database Server Distributor SQL Server must already be snstelled with an instance of SPSQL This option wil install the Riyionel Database Server C Regional Database Server on a local client A Distributor must be selected from ist b
256. oftware in the appropriate language to the operating system you are installing You cannot install Facility Commander Wnx until this is accomplished The following components cause the system to restart when a new version is installed e NET Framework e Windows Installer If your computer restarts log on as administrator and installation continues The Facility Commander Wnx installation processes updates on your system When the latest versions of each component are updated and identified Facility Commander Wnx installation begins and the Welcome window opens Continue with Facility Commander Wnx software installation begins on page 146 Facility Commander Wnx software installation begins Note A Cancel button displays on every FCWnx installation window If you click Cancel at any time during the installation the FCWnx installation process stops but all Windows components that have been installed must be manually removed To install the File server and FCWnx client application on second computer 1 2 The Facility Commander Wnx Welcome window opens Click Next When the License Agreement window opens select accept the license agreement and then click Next The Select Installation Type window opens as shown in Figure 100 Select the type of installation as Custom and then click Next FCWnx 7 7 Global Edition Installation Manual 169 Chapter 4 Install Global Edition Regional configuration Figure 100 Sele
257. omain Secure Domain User Name Password Wise Installation Wizard 4 Enter the user domain and username in the format Domain Username or click Browse to navigate the Windows network and select Enter the domain user password in the Password field Click Next to display the Select Credential Aliasing Option window This feature allows you to assign a credential number that represents the encoded credential number This provides added security in that the encoded number is only displayed to authorized users e Do not use aliases indicates no aliasing will be used e Use aliases automatically provided by FCWnx assigns the credential number for you e Use aliases manually provided by user aliasing allows you to assign the number 8 Choose one aliasing option then click Next The Change the Secure password window opens FCWnx 7 7 Global Edition Installation Manual 95 Chapter 3 Installing Facility Commander Wnx Global configuration 9 The Facility Commander Wnx installation creates a new Windows User ID called secure By default the password is SecurityMaster08 case sensitive If your Windows network has security policies that enforce rules for password creation you may need to change the secure user password If you are unsure ask your system administrator Select one of the following on the Change the Secure password window e Use Default Password e Change Password If you select this opti
258. ommander Wnx copies system files updates the system configuration and displays the Facility Commander Wnx icon on your desktop This may take a few minutes 12 When the Facility Commander Wnx has been successfully installed window opens click Finish 13 Continue with Licensing your Facility Commander Wnx system on page 108 68 FCWnx 7 7 Global Edition Installation Manual Chapter 3 Installing Facility Commander Wnx Global configuration Database server and FCWnx client application configuration Components Computer 1 Computer 2 Computer 3 Database server v File server v FCWnx client application Note This configuration has the database server and the FCWnx client application installed on Computer 1 while file server is installed on Computer 2 Database server and FCWnx client application on first computer To install the database server and FCWnx client application on the first computer 1 On the FCWnx Global Custom Configuration window select Database Server Global and FCWnx Client Application Figure 34 FCWnx Global Custom configuration Database server and FCWnx client application re Facility Commander Wnx 7 7 Setup Dj x FCVnx Global Custom Configuration O Choose the appropriate components for a custom Global Edition installation 1 IV Database Server Choosing this option will install the FC Wnx database components Please select which type of server Global Only one of thes
259. on enter your new password and then enter a second time 10 Click Next The Ready to Install the Application window opens 11 Enter the SQL Server password for the sa user This password was previously created during installation of SQL Refer to Installing Microsoft SQL Server on page 17 12 The default Destination Folder is indicated You may want to install to another location Click Browse to navigate to the program folder of your choice for placement of Facility Commander Wnx files 13 Click Next to continue Facility Commander Wnx copies system files and updates the system configuration This may take a few minutes 14 When the Facility Commander Wnx has been successfully installed window opens click Finish 15 Remove the FCWnx Installation disc from the CD DVD drive 16 If your computer restarts log on and continue Creating the database custom installation To create the database 1 A Select Database Server Type window opens as shown in Figure 53 Select Global Database Server and click Next 96 FCWnx 7 7 Global Edition Installation Manual Chapter 3 Installing Facility Commander Wnx Global configuration Figure 53 Create FCWnx database Select database server type Select Database Server Type FCWnx Database Select the database installation option from the list below 5 This option will install a Global Database Server and Global Database Server Distribulor SQL S
260. opens 2 Select accept the license agreement and then click Next 3 The Select Installation Type window opens as shown in Figure 57 Select the type of installation as Custom 104 FCWnx 7 7 Global Edition Installation Manual Chapter 3 Installing Facility Commander Wnx Global configuration Figure 57 Select Installation type Custom Select installation Type Select the desired installation type Typical The most common application features will be installed This option a le is recommended for most users Custom amp Use this option to choose which application features you want z installed and where they will be installed Recommended for p advanced users wise Installation wizard Click Next The Install Facility Commander Wnx Client Server window opens When asked Is this computer part of a Facility Commander Wnx Global Edition installation select Yes 6 Click Next The FCWnx Global Custom Configuration window opens as shown in Figure 58 Check the check box for only FCWnx Client Application FCWnx 7 7 Global Edition Installation Manual 105 Chapter 3 Installing Facility Commander Wnx Global configuration Figure 58 FCWnx Global Custom configuration FCWnx Client Application 7 106 a Facility Commander Wnx 7 7 Setup FCWinx Global Custom Configuration Choose the appropriate components for a custom Global Edition installation Click Next T
261. or and shuts down the Facility Commander Wnx Client application Log Off Log off allows an operator to log off and another operator to log on without exiting the program Quitting Facility Commander Wnx application You have the option of logging off without shutting down the computer In this case the Facility Commander Wnx services are still running However you will not receive any alarm notifications To receive these notifications you need to have the Facility Commander Wnx client application running If you select the option to receive notifications on the Client Form you need to be logged in to the Facility Commander Wnx client application The alarm notification displays based on the operator s facility assignment which is evaluated upon login to the Facility Commander Wnx application Shutting down Caution You can cause serious damage to your computer if you do not follow the procedure above In fact the resulting damage may require that you reload all the software on your computer To do a total shutdown of Facility Commander Wnx and your computer 1 Exit the Facility Commander Wnx client application by selecting Exit from the File menu Enter your password in the Password field of the Exit window and click OK 2 From the Desktop click Start then Shut Down 3 From the Shut Down Windows form select the Shut down option and click OK 278 FCWnx 7 7 Global Edition Installation Manual Chapter 10 Logging off an
262. or the Video Monitoring and Control VMC application A folder that contains the language support files for the VMC application After the base install of FCWnx these folders are empty as no language kits have been installed yet As the language kits are installed the language support files are placed in this folder 112 FCWnx 7 7 Global Edition Installation Manual Chapter 3 Installing Facility Commander Wnx Global configuration Review the folders in your Facility Commander Wnx directory and continue with Facility Commander Wnx user accounts below Facility Commander Wnx user accounts 1 During the Facility Commander Wnx server computer installation a default Facility Commander Wnx local user account was set up for you If you choose to add users and assign or change user passwords review Defining user accounts on page 245 Note Default local group is SPAdmin Default local user name is secure and the password is SecurityMaster08 case sensitive Refer to documentation you received when you purchased your Windows 2003 Windows 2008 Windows Vista or Windows XP operating system for additional information on setting up a user and assigning passwords Adding a new user account To create a new Global User Group for the Facility Commander Wnx Global Database Server Active Directory 1 Click Start Programs Administration Tools and then Active Directory Users and Computers 2 Select then right
263. ord in the following text box es m Database Server instance Name GLOBAL32BIT SPSQL Enter Username ba Enter Password eens 116 FCWnx 7 7 Global Edition Installation Manual 4 Chapter 3 Installing Facility Commander Wnx Global configuration Ignore the sa User Name as displayed The Password field opens your previously assigned and encrypted SQL password If you purchased your Facility Commander Wnx system from UTC Fire amp Security a temporary password of SecurityMaster08 case sensitive was assigned for you Accept the password as displayed Click Next The Create Database Initialize the Database Creation window opens as shown in Figure 46 Each Facility Commander Wnx database consists of data files and transaction logs You have an option to place those components in different physical locations You may consider this if your IT Department has certain policies regarding database installation Consult with your IT Department for assistance e Data File Directory The Data File Directory field displays the default directory Accept the default as displayed or click the Browse button and browse to any folder location where data files will be stored Note If you are installing in a Cluster configuration the Distributor installs to the same path as the Cluster Data File Directory e Log File Directory The Log File Directory field displays the default directory Accept the default or click the Browse butto
264. osoft SQL Server 2008 communication configuration To enable the Protocols for SPSQL 1 Click Start All Programs Microsoft SQL Server 2008 Configuration Tools SQL Server Configuration Manager and then SQL Server Network Configuration 2 Double click Protocols for SPSQL One at a time right click on Shared Memory Named Pipes and TCP IP and then select Enabled 36 FCWnx 7 7 Global Edition Installation Manual Chapter 2 Windows Server 2003 2008 Standard and Enterprise Edition Server setup To enable the Protocols for SQL Native Client 1 From the SQL Server Configuration Manager click SQL Native Client 10 0 Configuration 2 Double click Client Protocols One at a time right click on Shared Memory Named Pipes and TCP IP and then select Enabled 3 Click File and then Exit 4 We recommend that you restart your computer at this time Additional SQL Server 2008 configuration for Global Edition Each database server and each regional server in an FCWnx Global system must have the Enable OPENROWSET and OPENDATASOURCE support for SQL 2008 option enabled true To configure surface area using facets 1 Click Start Programs Microsoft SQL Server 2008 and then SQL Server Management Studio 2 At the Connect to Server window verify that the Login and Password are correct and then click Connect 3 In Object Explorer right click the server and then click Facets 4 In the View Facets dialog box expand the
265. ote Using SQL Server backups can be scheduled so that you do not have to remember to back up your databases You should keep two backups of the server computer The Facility Commander Wnx data e The entire Facility Commander Wnx installation Facility Commander Wnx data You should back up this data more often since it changes so frequently While your internal policies may dictate your backup requirements we recommend that you create a backup at least every week Back up the database using Microsoft SQL Server 2005 2008 Management Studio Refer to Backing up the databases using SQL Server on page 283 Here are the databases that constitute the FCWnx data e SecurePerfect Database Contains configuration data such as credentials and controllers e SecurePerfectArchive Database Contains copies of history data based on archive period 282 FCWnx 7 7 Global Edition Installation Manual Chapter 11 Back up your Global Edition e SecurePerfectHistory Database on the Global server Contains current history including credential transactions and operator history from every region In addition to backing up the databases you should also back up several important data folders Back up the data folders using any backup method you wish Backing up to CD DVD is explained on Backing up Facility Commander Wnx folders on page 285 These data folders are found in the main Facility Commander Wnx folder and are e Designs Will
266. oup is Global any users added to the FCWnx Users group at the Active Directory will have permission to start the Facility Commander Wnx program o NOONAN Figure 62 SPAdmin Properties window SPAdmin Properties 2x General Members Member Of Managed By Members Active Directory Folder Administrator boca com Users fsi FCWnx Users boca com Builtin 1 Remove OK Cancel Apply Now any members added to the FCWnx Users group at the Domain Controller Active Directory will have permission to start Facility Commander Wnx at all Facility Commander Wnx system computers Verify that the user who is logging 114 FCWnx 7 7 Global Edition Installation Manual Chapter 3 Installing Facility Commander Wnx Global configuration on to the computer where Facility Commander Wnx is running is part of the SPAdmin group on the Domain Active Directory Note If you have just completed installation of the Global database server you are now ready to install the Regional database server Installation of Global database server and Regional database servers follow similar instructions Continue with Chapter 4 Install Global Edition Regional configuration Create FCWnx database utility The Create FCWnx Database feature is available on the Facility Commander Wnx program menu of computers with Typical server installed or Custom installation with the database server component installed Select this option if you are crea
267. owing site http Awww fargosupport com Run the printer driver installation Connect the USB cable and power on the printer when prompted during the installation Note When using a Fargo printer with an internal OMNIKEY 5121 or 5125 encoder you must download and install both the driver and API To download and install the internal OMNIKEY 5121 or 5125 encoder driver 1 308 Go to the following site http Awww hidglobal com driverDownloads php Select OMNIKEY from the drop down list Under the Products drop down select OMNIKEY 5125 Reader Board USB Prox Under Operating System select the appropriate O S Download the following files CardMan_Synchronous_API_V1_1_1_4 exe e Title OMNIKEY Synchronous API for Windows e Size 3232576 e Description OMNIKEY synchronous API V1 1 1 4 Release 10 10 07 3927kB OMNIKEY5x21_V1_2 2 7 exe e Title OMNIKEY 5x2x Driver Self Extractor for manual installation e Size 229838 e Description PC SC Driver for OMNIKEY 5121 5321 5125 5325 6321 V1 2 2 7 Release 2010 01 20 225 kB Windows 2000 XP 2k3 Server Vista 2k8 Server Windows 7 digitally signed for Win 2000 XP Vista 2k3 Server 2k8 Server amp Windows 7 FCWnx 7 7 Global Edition Installation Manual Appendix B Optional hardware and software 3 Install the OMNIKEY5x21_V1_2 2 7 exe V1 2 2 7 4 Run the CardMan_Synchronous_API_V1_1_1_4 exe This will extract the installer to C OMNI
268. p LPT available to your computer Verify the list of COM ports and numbers that you installed Setting up dial up modems Note If you purchased this system from UTC Fire amp Security the modem is already set up for you A dedicated support modem for use by UTC Fire amp Security business and support is highly recommended Micro modems are used to communicate with dial up micros For Micro 5 and PX 2000 modems we recommend that you lock the baud rate at 9600 Before a modem can be used with FCWnx it must be set up in the operating system Refer to your modem documentation and Windows documentation for more information If this modem is to be used to communicate with micros you must manually lock the speed of the modem at 9600 baud 306 FCWnx 7 7 Global Edition Installation Manual Appendix B Optional hardware and software To lock the speed of the modem at 9600 baud 1 Click Start and then Control Panel 2 From the Control Panel select Phone and Modem Options 3 On the Modems tab select the modem you are using for your micros click the Properties button 4 Inthe Maximum port speed field select 9600 Note Not all modems use the exact commands listed in the previous step If your modem does not use that command use the definitions below to select the equivalent command amp Q0 Selects direct asynchronous operation and turns off error correction data compression and automatic speed buffering ASB S37 Se
269. pane click on Options to display the Options page 8 You may select either Overwrite all existing backup sets or Append to the existing backup set The latter option is useful when using a tape that can hold a large quantity of data We recommend that you append to the file You can schedule the backup We recommend that you refer to the SQL Help for more information 10 We recommend that you select Verify backup when finished option to guarantee that you perform a good backup 11 Click OK to start the backup 284 FCWnx 7 7 Global Edition Installation Manual Chapter 11 Back up your Global Edition 12 When the Backup operation has been completed successfully window opens click OK 13 If you are backing up more than one database at this time repeat the steps in this section each database you want to back up Backing up Facility Commander Wnx folders We recommend that you back up the following folders If you purchased your system from UTC Fire amp Security then your system contains a CD DVD RW drive that can be used for backup purposes e Designs e Externals Firmware e Videos To back up FCWnx folders 1 In Microsoft Explorer navigate to the Facility Commander Wnx program folder Select the Designs Externals Firmware and Video folders 2 Copy the folders to your backup media Backing up the entire Facility Commander Wnx folder The entire Facility Commander Wnx folder should be backed up when
270. pe window opens as shown in Figure 106 Select Regional Database Server and in the Select Global Database Server field select the Global database server for this Regional database server Figure 106 Create FCWnx database Select database server type TAF FCWnx Database Select the database installation option from the list below C This option will install a Global Database Server and Siobal DIRE Serves Distributor SQL Server must already be installed with an instance of SPSQL ie i cone This option will install the Regional Database Server Reaoas teeene oe F er is A Distributor must be selected from ist below Select Global Database Server GLOBAL32BIT SPSQL 2 Click Next The Create Convert Database window opens as shown in Figure 107 176 FCWnx 7 7 Global Edition Installation Manual Chapter 4 Install Global Edition Regional configuration Ignore the sa User Name as displayed The Password field displays your previously assigned and encrypted SQL password If you purchased your Facility Commander Wnx system from UTC Fire amp Security a temporary password of SecurityMaster08 case sensitive was assigned for you Accept the password as displayed Figure 107 Create Convert Database Create Convert Database FCWnx 7 7 Database Collect login information To begin the database create convert process please supply the SQL Server SQL 2008 Express administrators username and password in the
271. plication activity This Global server hosts a Distributor whose role is to store history and miscellaneous information about merge replication One type of replication where the publisher updates all subscriber databases on a schedule with changes from the publisher s database also all subscriber s database changes are merged with the publisher A publication is a collection of one or more articles from one database This grouping of multiple articles makes it easier to specify a logically related set of data and database objects that you want to replicate together The Publisher is a server that makes data available for replication to other servers In addition to being the server where you specify which data is to be replicated the Publisher also detects which data has changed and maintains information about all publications at that site Pull subscriptions are created at the Subscriber and the Subscriber requests data and updates made at the Publisher Pull subscriptions allow the user at the Subscriber to determine when the data changes are synchronized which can be on demand or scheduled Push subscriptions can simplify and centralize subscription administration because you do not need to administer each Subscriber individually The Distribution Agent or Merge Agent runs at the Distributor when synchronizing a push subscription Push subscriptions are created at the Publisher and the replication agents propagate data and updates to
272. pply Click OK er Oe LO a Oe Ne 12 FCWnx 7 7 Global Edition Installation Manual Chapter 2 Windows Server 2003 2008 Standard and Enterprise Edition Server setup Setting the network properties Windows Server 2003 It is important that the same network properties are used for both the Facility Commander Wnx server and Client systems To check the network settings Q a e cb a Right click My Network Places Select Properties from the shortcut menu Right click the Local Area Connection icon and select Properties Select Internet Protocol TCP IP Click Properties Select one e Obtain an IP address automatically e Use the following IP address Note Facility Commander Wnx computers do not require static IP addresses If you selected Use the following IP address option you must obtain a valid IP address from the network administrator or use a local IP address that no other computer is using in your network Consult your network administrator for detailed instructions 7 Click OK 8 Click OK to exit Local Area Connection Properties 9 After Windows is installed restart the computer and make sure it is connected to the network Verify that you do not have any hardware errors under Device Manager Windows Server 2008 To check the network settings 1 Click Start and then click Control Panel Category view Click Network and Internet and then click Network Sharing Center Classic view Double cl
273. pply the SQL Server SQL 2008 Express administrators username and password in the following text box es Click Next The Create Database Initialize the Database Creation window opens as shown in Figure 99 Each Facility Commander Wnx database consists of data files and transaction logs You have an option to place those components in different physical locations You may consider this if your IT Department has certain policies regarding database installation Consult with your IT Department for assistance Data File Directory The Data File Directory field displays the default directory Accept the default as displayed or click the Browse button and browse to any folder location where data files will be stored Note If you are installing in a Cluster configuration the Distributor installs to the same path as the Cluster Data File directory Log File Directory The Log File Directory field displays the default directory Accept the default or click the Browse button and browse to the folder location where database log files will be stored Note This refers to the database logs this does NOT refer to the Facility Commander Wnx logs FCWnx 7 7 Global Edition Installation Manual Chapter 4 Install Global Edition Regional configuration Figure 99 Create Database Create Database es 5 xj FCWnx 7 7 Database Initialize the database creation Q Log View Error m Database Directory Informa
274. provided for changes to the computer name as applicable to your configuration e Ina Typical installation to the Database server computer e Ina Custom installation that has the database server file server and FCWnx Client Application installed on the same computer For any other scenario you must consult UTC Fire amp Security Customer Support for assistance You need to change the computer name in three areas 1 In System Properties 2 Using the SPServer exe utility 3 SQL Server Client Tools Enterprise level installations Details are included in the following sections Server Computer Name in System Properties Note These instructions assume that you are at the server computer of a Typical installation All database and Server components and the Facility Commander Wnx application are on the same computer If your database and Server components and application are on separate and different computers call UTC Fire amp Security Customer Support for assistance To change the server computer name in the Windows operating system Note You must be at the Database server computer 1 Stop Facility Commander Wnx services 2 Windows XP Professional e Right click the My Computer icon on your desktop and then click Properties Select the Computer Name tab from the System Properties window 3 Windows Vista and Windows 7 e Click Start right click Computer and then click Properties 272 FCWnx 7 7 Global Edition In
275. r Replication technology Reckoner requires that SQL Server Services are running using a domain uset account that DOs tine ato to eal pedi aid dec te ota Fore database servers that are part of the Global Edition installation The domain and user name should be entered with the following format Domain Use N ame For example SPDomain Secure Wise Installation Wizard 4 The Change the Secure password window opens as shown in Figure 88 The Facility Commander Wnx installation creates a new Windows User ID called secure By default the password is SecurityMaster08 case sensitive If your Windows network has security policies that enforce rules for password creation you may need to change the secure user password If you are unsure ask your system administrator Select one of the following on the Change the Secure password window e Use Default Password e Change Password If you select this option enter your new password and then enter a second time FCWnx 7 7 Global Edition Installation Manual 153 Chapter 4 Install Global Edition Regional configuration Figure 88 Change the Secure password window is Facility Commander Wnx 7 7 Setup Change the Secure password O Change the password for the Windows Logon USERID Secure The FCWru installation creates a new Windows USERID called Secure By default the password is SecurityMaster08 If your Windows network has secunty policies
276. r Wnx services such as monitoring and transferring events or alarms will not function if the computer is in Sleep Mode or Hibernate Mode Make sure that your computer setting for Sleep Mode and Hibernate Mode is set to NEVER It is also a good practice to set your Turn off display setting to Never Refer to the documentation that came with your version of Windows for details on these settings or check with your IT department Note For the Credential Designer features to function properly the Windows operating system must be installed on drive C Insert the Windows Installation disc in your CD DVD drive and follow the instructions provided by the Microsoft documentation Note If you purchased this system from UTC Fire amp Security the operating system is installed for you This section represents an overview of the installation procedure and does not provide step by step instructions to install the operating system During the installation of the operating system you will be asked to select a file system type For added security we recommend that you select NTFS For additional information consult your Microsoft documentation Assigning user passwords We recommend that you assign a password to all user accounts This will avoid security permission issues when attempting to access remote client computers Refer to your Windows XP Professional documentation for additional information on setting up a user and assigning password
277. r computer at this time NO OL i Microsoft SQL Server 2005 communication configuration To enable the Protocols for SPSQL 1 Click Start All Programs Microsoft SQL Server 2005 Configuration Tools SQL Server Configuration Manager and then SQL Server Network Configuration 2 Double click Protocols for SPSQL One at a time right click on Shared Memory Named Pipes and TCP IP and then select Enabled 26 FCWnx 7 7 Global Edition Installation Manual Chapter 2 Windows Server 2003 2008 Standard and Enterprise Edition Server setup To enable the Protocols for SQL Native Client 1 From the SQL Server Configuration Manager click SQL Native Client 10 0 Configuration 2 Double click Client Protocols One at a time right click on Shared Memory Named Pipes and TCP IP and then select Enabled Click File and then Exit 4 We recommend that you restart your computer at this time Additional SQL Server 2005 configuration for Global Edition Each database server and each regional server in an FCWnx Global system must have the following configuration To configure database and regional servers 1 Click Start select Programs Microsoft SQL Server 2005 Configuration Tools and then SQL Server Surface Area Configuration to display a window as shown in Figure 9 below Figure 9 SQL Server 2005 Surface Area configuration 3 SQL Server 2005 Surface Area Configuration i Help Protect Your SQL Server Enable oniy the se
278. re By default the password is SecurityMaster08 case sensitive If your Windows network has security policies that enforce rules for password creation you may need to change the secure user password If you are unsure ask your system administrator Select one of the following on the Change the Secure password window e Use Default Password e Change Password If you select this option enter your new password and then enter a second time Click Next The Ready to Install the Application window opens Enter the SQL Server password for the sa user This password was previously created during installation of SQL Refer to Installing Microsoft SQL Server on page 17 FCWnx 7 7 Global Edition Installation Manual 175 Chapter 4 Install Global Edition Regional configuration 7 The default Destination Folder is indicated You may want to install to another location Click Browse to navigate to the program folder of your choice for placement of Facility Commander Wnx files 8 Click Next to continue Facility Commander Wnx copies system files and updates the system configuration This may take a few minutes 9 When the Facility Commander Wnx has been successfully installed window opens click Finish 10 Remove the FCWnx Installation disc from the CD DVD drive 11 If your computer restarts log on and continue Creating the database custom installation To create the database 1 The Select Database Server Ty
279. red for you and ports are opened during installation e lf you use secure authentication skip to step 10 e If you do not wish to use secure authentication clear the Default check box and complete the remaining fields on the window If you cleared the Default check box these fields are enabled 5 In the Username field enter a domain or local user name for this user 6 In the Password field enter a domain or local password for the user listed in the Username field In the Password Confirm field enter the domain or local password a second time identical to what was entered in the Password field FCWnx 7 7 Global Edition Installation Manual 235 Chapter 9 License and Set Security Settings for your FCWnx System 8 In the Domain field enter the name of the FCWnx domain 9 Items to note e The username and password are used to authenticate remote DCOM objects e To keep interruptions to the FCWnx application to a minimum your IT Department may choose to set passwords as never expiring e If any computer in your FCWnx system uses DCOM authentication then all other client computers must use DCOM authentication 10 Click Next to continue The settings are automatically saved to your computer and DCOM is configured for FCWnx 11 The Firewall Configuration window opens 12 The following port numbers display by default e Controller Communications Port 6699 e Client Workstation Server Communications Port RPC 135
280. required to restart this application to continue operations This sequence continues indefinitely if you have not properly licensed your system Operation during Demo Mode is limited to the following e 2client computers e 1 Imaging session e 4readers e 4cameras e 1 API connection e Client Redundancy e Guard Tours e Graphics console e Controller support To license the second and any additional clients 1 If the license program is not already open select Start Programs Facility Commander Wnx then FCWnx License The License Setup page opens 2 Click OK on the License Setup dialog box if you have not already done so 3 The First Time License check box is clear Ignore and do not select 4 SQL Password for FCWnx This field is disabled and was completed when First Time License was completed 5 Select the Warranty Reminder in the Days before Expiration group box and enter or select the number of days before expiration of your warranty that you want a reminder to begin displaying in your application This field accepts a number between 0 and 120 License Controller 6 The Machine Seed Key is displayed for information only and is a read only field FCWnx 7 7 Global Edition Installation Manual 229 Chapter 6 License and Set Security Settings for your FCWnx System 7 Ignore the License Key section This section is disabled and was completed when First Time License was completed File server Note If the
281. rk properties 243 Windows XP Professional 243 Windows Vista and Windows 7 244 Defining user accounts 245 Items specific to Windows XP Professional 245 Disable simple file sharing 245 Firewall exceptions list 246 Items specific to Windows Vista 246 Windows communication foundation HTTP activation 246 FCWnx 7 7 Global Edition Installation Manual 239 Chapter 7 Windows 7 Vista and XP Professional system setup Firewall exceptions list 247 Disable automatic windows update feature 247 Items specific to Windows 7 247 Windows communication foundation HTTP activation 247 Firewall exceptions list 248 What s next 248 Preinstallation checklist To prepare your Windows XP Professional computer refer to this checklist Note If you purchased this system from UTC Fire amp Security these tasks were completed for you e Meet the minimum recommended hardware and software requirements e Install the network board e Configure the computer for the network e Install Windows 7 Windows Vista or Windows XP Professional with the appropriate Service Packs e Set the monitor resolution to a minimum of 1024 by 768 pixels Set the Network Properties Network card Note If you purchased this system from UTC Fire amp Security the network card is installed for you If it is not already installed install the network card now Follow the instructions included with the board Verify that you are using the same network card speed as th
282. roubleshooting maintenance support Contacting technical support For assistance installing operating maintaining and troubleshooting this product refer to this document and any other documentation provided If you still have questions you may contact presales and technical support Note Be ready at the equipment before calling for technical support You can reach technical support by phone 8 a m to 7 p m EST Monday through Friday North America T 888 437 3287 F 561 998 6224 Asia T 65 639 19314 F 65 639 19306 Australia T 61 3 9239 1200 F 61 3 9239 1299 Canada T 800 267 6317 F 613 737 5517 EMEA T 48 58 326 22 40 F 48 58 326 22 41 Latin America T 503 691 7294 F 561 994 6572 Email rs bctsupport fs utc com Web site www utcfireandsecurity com 298 FCWnx 7 7 Global Edition Installation Manual Appendix A UL certification requirements Summary This appendix provides a list of installation requirements necessary for a UL Listed Facility Commander Wnx system Content UL specifications and requirements 300 FCWnx 7 7 Global Edition Installation Manual 299 Appendix A UL certification requirements UL specifications and requirements Facility Commander Wnx is a UL Listed system UL 1076 Proprietary Burglary Requirements UL 294 Access Control Requirements You must adhere to the following requirements in a UL Listed installation 1 The computer and monitor shall be completely dup
283. rs 5 A message opens FCWnx Database successfully created Note A log file is created when the Create Database program is run The log file called CreateDatabaseLog is found in the Logs folder The Integrity utility runs automatically following a database creation No user interaction is required Refer to your Facility Commander Wnx Online Help for addition information about the Integrity utility Click OK The dialog box closes If you receive a message to restart at this time click Yes to restart log on and continue 8 An FCWnx License Setup window opens Unless otherwise stated in your configuration scenario proceed to When Regional custom configurations are complete Proceed to Licensing your Facility Commander Wnx system below if you have not already licensed Licensing your Facility Commander Wnx system on page 187 198 FCWnx 7 7 Global Edition Installation Manual Chapter 5 Configuring Global Edition for file replication Summary This chapter includes instructions for Facility Commander Wnx Global Edition configuration for file replication We recommend that you review the entire chapter and discuss with your IT Department before you begin your configuration Content Configuring file replication services 200 File Replication on Windows 2003 with SQL 2005 201 Verifying Distributed File System service is started 201 Creating Dfs Root 201 Creating a New Dfs Link 206 Creating a New Replica
284. rties 243 FCWnx 7 7 Global Edition Installation Manual Defining user accounts 245 Items specific to Windows XP Professional 245 Items specific to Windows Vista 246 Items specific to Windows 7 247 What s next 248 Chapter 8 Installing Facility Commander Wnx Software on additional clients 249 Defining additional clients 250 Reaching the First Time License computer over the network 250 Installing Facility Commander Wnx Windows 7 Windows Vista or Windows XP Professional additional client computer 253 Licensing the client computer 258 Setting services to automatic startup 258 Items specific to Windows Vista and Windows 7 260 Global configuration client installations 260 Logging on to client computer 260 Viewing Imaging status 261 Client folder structure 263 What s next 264 Chapter 9 Logging on and configuring Facility Commander Wnx 265 Facility Commander Wnx services overview 266 Starting Facility Commander Wnx 269 Logging on 270 Accessing help 270 Defining additional user accounts 271 Initial setup of Facility Commander Wnx records 271 Setting e mail accounts 271 Changing the Facility Commander Wnx server computer name 272 Server Computer Name in System Properties 272 Server Computer name change using SPServer exe utility 273 Chapter 10 Logging off and shutting down 277 Exiting Facility Commander Wnx 278 Automatic client shutdown 279 Chapter 11 Back up your Global Edition 281 Backup of Global Edition database
285. rver Services window opens as shown in Figure 43 on page 82 Note Each server used in the Facility Commander Wnx Global Edition system requires the database services to run under a domain user name and password account This account must have administrative privileges to that particular computer We suggest that you use the identical domain account at each computer used in the UTC Fire amp Security system FCWnx 7 7 Global Edition Installation Manual 81 Chapter 3 Installing Facility Commander Wnx Global configuration Figure 43 Logon account for SQL server services fe Facility Commander Wnx 7 7 Setup Bins ae AE xj Logon Account for SQL Server Services Enter the domain user account to be used by Microsoft SOL Server for replication Enr Global Edition uses Microsoft SQL Server Replication technology Replication requires that SQL Server Services are running using a domain uset account that has administrator privileges on both the local machine and also on the other FOWnx database servers that are part of the Global Edition installation The domain and user name should be entered with the following format Domain UsemName For example SPDomain Secure Domain U ser Name Browse Password Wise Installation Wizard 6 Enter the user domain and username in the format Domain Username or click Browse to navigate the Windows network and select Enter the domain user password in the Password field Click
286. rver software is user supplied and is not included as part of a Facility Commander Wnx system The SQL Server program stores and controls the Facility Commander Wnx databases If you do not have SQL Server installed on the server computer that will store your databases you must install it now The following procedures provide a standard installation and based on your needs you may choose other available features There are two versions e Microsoft SQL Server 2005 below e Microsoft SQL Server 2008 on page 29 Microsoft SQL Server 2005 Installing Microsoft SQL Server 2005 To install Microsoft SQL Server 2005 1 Insert Disc 1 of Microsoft SQL Server 2005 CD or the product DVD into the CD DVD drive and wait as the Microsoft SQL Server 2005 window automatically opens 2 When the Start window opens select Server components tools Books Online and samples as shown in Figure 1 FCWnx 7 7 Global Edition Installation Manual 17 Chapter 2 Windows Server 2003 2008 Standard and Enterprise Edition Server setup Figure 1 SQL Server 2005 Start SQL Server 2005 Disc 1 of 2 Launch the Installation Wizard to install sei ponen managemen ools Onlin Microsoft SQL Server 2005 Developer Edition Prepare Review hardware and software requirements Read the release notes Install SQL Server Upgrade Advisor Install Server components tools Books Online and samples Run the SQL Native Client Installation Wi
287. rvices with an automatic startup which means that it starts as soon as the computer is started We recommend that you do not change this setting However should you need to start them manually keep the following in mind These services need to start in the following order and stopped in the reverse order e FCWnx Diagnostics If you stop FCWnx Diagnostics all services stop FCWnx System Manager FCWnx WCF Service e FCWnx Manager e FCWnx Media Server e FCWnx Webservice If you start FCWnx Webservice all services start FCWnx 7 7 Global Edition Installation Manual 267 Chapter 9 Logging on and configuring Facility Commander Wnx Figure 155 FCWnx component services Name Description Status Startup Type Log On As S Encrypting File System EFS Provides the core file encrypt Manual Local System Gh Extensible Authentication Protocol The Extensible Authentication Manual Local System Gh Fax Enables you to send and rec i Manual Network Service Sh FCWnx API Service Provides COM API for use by Manual Local System F Stop the service Restart the service Description Provides logging support for FCWnx services and applications nx Diagno Provides logging support fo al System l and Local System 2 O Sh FCWnx Manager Manages FCWnx physical 4 FCWnx Media Server Provides video device services Local System Gh FCWnx System Manager Manages FCWnx low level int Local System Sh FCWnx WebServi
288. rvices and connection types used by your appheations Disabling unused services and connections helps protect your server by reducing the surface area For default settings see Help Select a component and then configure its services and connections 4 SPSOL By default SOL Server 2005 Express Evaluation and Developer editions alow local a jj Database Engre cn aoa anen bie Erterpiise Standard and Workgroup edtions also sten for Seni connections over TCP IP Use the options below to change t ae cnutich SL Server kstens for incoming client connections TCPAP is prefered over Remate Lonnections named pipes because it requires fewer ports to be opened across the freweall E Analysis Services cy ag Reporting Services SQL Server Agert g Ss tr f Local connections a IA Full Text Search oy E E Ietegration Services Local and remote connections 5 a SQL Server Browser C Using CPAP only C Using named pipes only C Using both TCPAP and named pipes CE ee joo FCWnx 7 7 Global Edition Installation Manual 27 Chapter 2 Windows Server 2003 2008 Standard and Enterprise Edition Server setup 2 When the Surface Area Configuration for Services and Connections window opens select Local and remote connections and then Using both TCP IP and named pipes as shown in Figure 10 below Click OK Figure 10 Local and remote connections SQL Server 2005 Surface Area Configuration i Help Protect Your SOL Server Enable oniy the s
289. rvices and scroll down See Figure 154 Figure 154 Facility Commander Wnx services Windows i Services ay 10l x action vow e gt aR se q Tree Services Local Ss Distributed Transaction Coordinate Manual LocalSystem SY DNS Client Resolves a Started Automatic LocalSystem Ss Event Log Logs event Started Automatic LocalSystem Sa Fax Service Helps you Manual LocalSystem Sa FCWnx API Service Manual LocalSystem ePCWwnx Diagnostics Manual LocalSystem Sa FCWN Manager Manual LocalSystem Sa FCWnx Media Server Manual LocalSystem Sa FCWN System Manager Manual LocalSystem Sy FCwnx WebService Manual LocalSystem Sa InCD Helper Helper ser Started Automatic LocalSystem Sy IncD Helper read only Helper ser Automatic LocalSystem Sa Indexing Service Manual LocalSystem amp Internet Connection Sha Provides n Manual LocalSystem By IPSEC Policy Agent Manages I Started Automatic LocalSystem gt athe a s a The status will be either Started or blank If it is blank then the service is not running Caution Changing the state of services without a good working knowledge of the services purpose can cause the computer to act erratically During your installation sequence services were set to automatic Refer to Setting Services to Automatic Startup in the section of this Manual that pertains to your system setup Once set to automatic FCWnx initializes these se
290. s Setting up your monitor The minimum recommended monitor resolution required for Facility Commander Wnx is 1024 by 768 Small Fonts must be selected on the General tab of the 242 FCWnx 7 7 Global Edition Installation Manual Chapter 7 Windows 7 Vista and XP Professional system setup Advanced properties If using Imaging the minimum color resolution is High Color 16 bit To access the display settings 1 Right click your mouse on the desktop Select Properties from the menu Click the Settings tab in the Display Properties window Change the Screen resolution to at least 1024 by 768 pixels Change the Color quality to at least 16 bit if using imaging Click Apply Click OK Se OS ON EBS Ges Setting the network properties It is important that the same network properties are used for both the Facility Commander Wnx Server and Client systems Windows XP Professional To check the network settings 1 Right click My Network Places 2 Select Properties from the shortcut menu 3 Right click the Local Area Connection icon and select Properties The Local Area Connection Properties window opens 4 Select Internet Protocol TCP IP 5 Click Properties 6 Select one e Obtain an IP address automatically Use the following IP address Note Facility Commander Wnx computers do not require static IP addresses However if you selected Use the following IP address option you must obtain a valid IP address fro
291. s Select Named Instance and then enter SPSQL Click Next See Figure 14 on page 32 Note It is very important that you enter the correct instance for the appropriate product FCWnx 7 7 Global Edition Installation Manual 31 Chapter 2 Windows Server 2003 2008 Standard and Enterprise Edition Server setup Figure 14 Instance Configuration REE Instance Configuration Specify the name and instance ID for the SQL Server instance Setup Support Rules C Default instance Feature Selection Named instance Instance Configuration Disk Space Requirements Server Configuration Instance ID Database Engine Configuration ase Engine gui Instance root directory C Program Files Microsoft SQL Server Reporting Services Configuration Error and Usage Reporting Installation Rules SQL Server directory C Program Files Microsoft SQL Server MSSQL10 5PSQL Ready to Install Reporting Services directory C Program Files Microsoft SQL Server MSRS10 SPSQL Installation Progress Complete Installed instances Features Edition Version Instance ID lt Back Next gt Cancel Help 18 The Disk Space Requirements window opens Click Next 19 The Server Configuration window opens Click the Service Accounts tab and then configure settings as follows See Figure 15 on page 33 Click Use the same account for all SQL Server services to apply the same username and password to the SQL Server Agent SQL Server Datab
292. s 282 Chapter 12 Uninstall Facility Commander Wnx or delete a database 287 Uninstalling Facility Commander Wnx software 288 Deleting the database 291 FCWnx 7 7 Global Edition Installation Manual iii Removing Microsoft SQL Server 291 Chapter 13 Troubleshooting maintenance support 293 Troubleshooting 294 Contacting technical support 298 Appendix A UL certification requirements 299 UL specifications and requirements 300 Appendix B Optional hardware and software 303 Installing FCWnx on a thin client terminal server 304 Setting up a Digi serial port expander 305 Setting up dial up modems 306 Setting up the Fargo DTC550 printer encoder for smartcard encoding with FCWnx 307 Appendix C CCTV Interfaces 311 Overview 312 Software requirements 312 American Dynamics system 313 Burle Allegiant system 318 Kalatel system 325 Pelco system 331 Mapping FCWnx alarms to CCTV alarms 337 Monitoring 337 Diagnostics 338 Removal of CCTV client interface 338 iv FCWnx 7 7 Global Edition Installation Manual Preface Welcome to Facility Commander Wnx This manual provides information for system administrators to set up install and configure a Facility Commander Wnx Global configuration system Throughout this manual reference to Facility Commander Wnx is represented as FCWnx in text content to avoid repetition Safety terms and symbols These terms may appear in this manual Caution Cautions identify conditions or practices that ma
293. s installation scenario there is only one Publisher on the Global database instance Refer to Figure 19 on page 42 The Facility Commander Wnx Merge Publication is defined To define a publication the database to be replicated is selected Within that publication articles are defined The articles are representative of the tables contained within the database FCWnx 7 7 Global Edition Installation Manual Chapter 3 Installing Facility Commander Wnx Global configuration 5 After the Publication is defined the initial Snapshot Agent is started This Agent will create an image of the database at that moment in time Subscribers will utilize this snapshot later 6 The SecurePerfectGlobalHistory database is created This database is only present in the Global database server of a Global Edition installation The following history tables are contained within AlarmHistoryTable BadgeHistoryTable DlHistory DOHistory DVMRHistory GuardTourHistory OperatorHistoryTable ZoneHistoryTable 7 A message opens FCWnx Database successfully created Note A log file is created when the Create Database program is run The log file called CreateDatabaseLog is found in the Logs folder The Integrity utility runs automatically following a database creation No user interaction is required Refer to your Facility Commander Wnx Online Help for addition information about the Integrity utility 8 Click OK The dialog box closes If you rece
294. s option will install the FCwnx File Server components I FCWnx Client Application Choosing this option will install the FCWnx Client Application Wise Installation Wizard seek Ne ca FCWnx 7 7 Global Edition Installation Manual 173 Chapter 4 Install Global Edition Regional configuration 2 Click Next The Database and FileServer Paths window opens as shown in Figure 104 At the Database and FileServer Paths window the Database Server Name displays as read only It is unavailable for entry If the displayed Global Database Server Name is not appropriate select the appropriate Name from the drop down list If the File Server Name displays accept the entry as listed or click Browse to navigate to another computer that may serve as File Server for your system and then select that computer name to display in this dialog box Note You must install the File Server on the selected file server in your Facility Commander Wnx system before attempting to license any Facility Commander Wnx application Figure 104 File server name required 3 174 i Facility Commander Wax 7 7 Setup Bs O xj Global Database and FileServer Paths Global Database Server Name z File Server Name EEEE ENEE Browse Wise Installation Wizard _ lt Beck Net _ Cancel The Logon Account for SQL Server Services window opens as shown in Figure 105 Note Each server used in the Facility Commander Wnx Gl
295. s option will install the FCwnx File Server components IV FCWnx Client Application Choosing this option wall install the FCWnx Client Application Wise Installation Wizard lt Beck Net coe 7 Click Next The Database and File Server Paths window opens as shown in Figure 33 on page 68 If a displayed Database Server Name is not correct enter or select the appropriate name from the drop down list If a displayed File Server Name is not correct navigate to the file server computer for this client and select to display in the File Server Name dialog box FCWnx 7 7 Global Edition Installation Manual 67 Chapter 3 Installing Facility Commander Wnx Global configuration Figure 33 Database and file server paths Global Database and FileServer Paths O Global Database Server Name Database Server Name z File Server Name AA UU Wise Installation Wizard tox Te ces 8 Click Next The Change the Secure password window opens 9 Select one of the following e Use Default Password e Change Password If you select this option enter your new password and then enter a second time 10 Click Next The Ready to Install the Application window opens The default Destination Folder is indicated You may want to install to another location Click Browse to navigate to the program folder of your choice for placement of Facility Commander Wnx files 11 Click Next to continue Facility C
296. s time click Yes to restart log on and continue 8 An FCWnx License Setup window opens You cannot license at this time Click Cancel to exit License Setup 9 Continue with configuration of the file server on a second Windows 2003 or 2008 Standard server computer File server on second computer Now you must select and install only the file server component on a separate Windows 2003 or 2008 Standard server computer Note Prerequisite database server and FCWnx client application installation already complete If you do not install the file server at this time you will not be able to license your system 76 FCWnx 7 7 Global Edition Installation Manual Chapter 3 Installing Facility Commander Wnx Global configuration To install required components 1 Verify that the computer you are configuring meets minimum requirements 2 Insert the FCWnx installation disc into the CD DVD drive When prompted click Run autorun exe If the disc does not launch you must manually start the software Using Windows Explorer navigate to the FCWnx Installation disc and then double click autorun exe 3 The Facility Commander Wnx Main Menu opens Click Install FCWnx v7 7 4 The Facility Commander Wnx introduction page opens Click Install A series of windows may display as the listed components automatically install if not already there These components may cause the system to restart when a new version is installed If your computer re
297. s to prompts and click Next to continue During installation you are prompted with a few questions e Type of CCTV Interface Select Pelco e Description or name for the interface Enter a description for this interface such as Main Building CCTV Note If multiple same type CCTV interfaces are installed on a single FCWnx network the description of each interface must be unique e COM port to which this interface is connected Select the COM port Click Install to complete the installation Once the installation is complete from the Control Panel select System Hardware tab Device Manager and then Ports Select the COM port you previously selected in the installation and provide identical settings for baud rate data bits parity stop bits and flow control as your CCTV Controller s setup When you are ready to launch the CCTV program you need to restart the FCWhnx services on this client Once the system is running log on to the computer as an FCWnx user and start the FCWnx application Log on to FCWnx and from the Application Group pane Monitors and Controls group select Client Monitor You notice an entry for the CCTV you just installed To start the CCTV application you need to create CCTV alarms in the CCTV Alarm form first Then you need to map the desired FCWnx alarm to CCTV on FCWnx 7 7 Global Edition Installation Manual the Alarm form CCTV tab Configuring alarms below and Monitoring on page
298. s updates on your system When the latest versions of each component are updated and identified Facility Commander Wnx installation begins and the Welcome to the Facility Commander Wnx 7 7 Installation Wizard window opens Continue with Facility Commander Wnx software installation begins below Facility Commander Wnx software installation begins Note A Cancel button displays on every FCWnx installation window If you click Cancel at any time during the installation the FCWnx installation process stops but all Windows components that have been installed must be manually removed To install the Facility Commander Wnx application 1 The Facility Commander Wnx Welcome window opens Click Next The License Agreement window opens Select accept the license agreement and click Next 3 Select Custom in the Select Installation Type window as displayed in Figure 20 You must select Custom in order to install a Facility Commander Wnx Global Edition system FCWnx 7 7 Global Edition Installation Manual 47 Chapter 3 Installing Facility Commander Wnx Global configuration Figure 20 Select Installation type window Select installation Type Select the desired installation type Typical The most common application features will be installed This option is recommended for most users Custom Use this option to choose which application features you want installed and where they will be installed Recommended for adva
299. s using in your network Consult your network administrator for detailed instructions Click OK Click OK to exit Local Area Connection Properties After Windows is installed restart the computer and make sure it is connected to the network Verify that you do not have any hardware errors under Device Manager 244 FCWnx 7 7 Global Edition Installation Manual Chapter 7 Windows 7 Vista and XP Professional system setup Defining user accounts Windows requires that a user account be set up for each user on that computer and for each user accessing the Server remotely This section addresses adding user accounts and assigning user passwords The User Accounts selection in Control Panel allows you to add users to your computer and to add users to a group Permissions and user rights are usually granted to groups By adding a user to a group you give the user all the permissions and user rights assigned to that group During installation of the FCWnx application the user group SPAdmin is created Users must be a member of the SPAdmin group to perform most of the tasks necessary to operate the FCWnx system The user secure is automatically created during installation and is part of the Users and SPAdmin group by default Note If you do choose to add additional users you must assign them to the group SPAdmin after Facility Commander Wnx is installed Items specific to Windows XP Professional Disable simple file
300. se Edition Server setup Figure 11 Surface Area Configuration for Features b Surface Area Configuration for Features localhost x 3 SQL Server 2005 Surface Area Configuration amp Help Protect Your SQL Server Enable only the features requred by your applications Disabling unused features helps protect your server by reducing the surface area For default settings see Help Select a component and then configure its features 1 g SPSQL The GPENROWSET and OPENDATASOURCE functions support ad hoc connections E jj Database Engine to remote data sources without Inked or remote servers Enable these functions only if EEr our applications and scripts call them CLR Integration DAC Database Mail Native XML Web Services OLE Automation Service Broker SQL Mail Web Assistant xp_omdshell M Enable OPENROWSET and OPENDATASOURCE support al View by Instance View by Component C c toy tee Note Each database server and each regional server in an FCWnx Global system must have this configuration Microsoft SQL Server 2008 Installing Microsoft SQL Server 2008 To install Microsoft SQL Server 2008 1 Insert the Microsoft SQL Server 2008 CD or the product DVD into the CD DVD drive and wait as the Microsoft SQL Server 2008 window automatically opens 2 When the AutoPlay window opens click Run SETUP EXE A window displays a list of prerequisites required prior to installing SQ
301. sharing Simple File Sharing is a feature in Windows XP that removes file sharing security options available in other version of Windows This setting must be disabled for FCWnx to operate successfully between Servers and clients Once the user sets the permission the user and clients have access to shared files and the ability to assign passwords to shares To disable simple file sharing 1 Double click My Computer on the Windows XP desktop 2 From the Tools menu select Folder Options to open a Folder Options window 3 Click the View tab and locate the Use simple file sharing Recommended check box in the list of Advanced Settings 4 To disable Simple File Sharing ensure this check box is cleared Check the check box to disable the option The Simple File Sharing check box should be at or near the bottom of the Advanced Settings list FCWnx 7 7 Global Edition Installation Manual 245 Chapter 7 Windows 7 Vista and XP Professional system setup 5 Click OK to close the Folder Options window The settings for Simple File Sharing are now updated no computer restart is required Enabling Simple File Sharing prevents the ability to assign user level passwords to shares When Simple File Sharing is enabled on a computer remote users are not prompted for a password when accessing that computer s shares If the Windows XP Professional computer is part of a Windows domain rather than a Windows workgroup this process for enabl
302. soft SOL Server for replication Global Edition uses Microsoft SQL Server Replication technology Replication requires that SOL Server Services are running using a domain uset account that has administrator privileges on both the local machine and also on the other FOWnx database servers that are part of the Global Edition installation The domain and user name should be entered with the following format Domain Use N ame For example SPDomain Secure Domain User Name Password Wise Installation Wizard 3 Enter the user domain and username in the format Domain Username or click Browse to navigate the Windows network and select Enter the domain user password in the Password field Click Next The Select Credential Aliasing Option window opens This feature allows you to assign a credential number that represents the encoded credential number This provides added security in that the encoded number is only displayed to authorized users e Do not use aliases indicates no aliasing will be used e Use aliases automatically provided by FCWnx assigns the credential number for you e Use aliases manually provided by user aliasing allows you to assign the number 7 Choose one aliasing option then click Next The Change the Secure password window opens 8 In the Change the Secure password window select one of the following e Use Default Password e Change Password FCWnx 7 7 Global Edition I
303. stallation Manual Chapter 9 Logging on and configuring Facility Commander Wnx Inthe Computer name domain and workgroup settings click Change settings Select the Computer Name tab from the System Properties window Enter the new name of the server computer It should consist of a maximum of 15 alphanumeric characters with no spaces Click Change to open the Computer Name Changes window You can change the name and the membership of your computer Changes may affect access to network resources Click OK or Cancel to return to the System Properties window Click Apply and then click OK You will be asked to restart your computer Select Yes Server Computer name change using SPServer exe utility Note These instructions must be followed on every computer in your Facility Commander Wnx system including the server computer This step changes the computer name for the Facility Commander Wnx application FCWnx has a utility to assist you in changing your server computer name To change the server computer name 1 2 Stop Facility Commander Wnx services If you need assistance review Navigate to the FCWnx folder of your server computer The default is Program Files GE FCWnx Double click the SPServer exe file The FOWnx Server Name Definition window opens similar to Figure 157 on page 274 FCWnx 7 7 Global Edition Installation Manual 273 Chapter 9 Logging on and configuring Facility Commander Wnx Figure 157 FCW
304. starts log on as Administrator and installation continues NET Framework e Windows Installer Note On rare occasions when installing Facility Commander from a DVD drive the installation will stall for approximately 10 to 20 minutes from the time you click Install to the time when the Welcome to Facility Commander Wnx 7 7 Installation Wizard page opens If this occurs it is most likely caused by your anti virus software If you have anti virus software running you must configure it so that the DVD drive is not scanned Refer to the documentation that came with your anti virus software for details 5 The Facility Commander Wnx installation processes updates on your system When the latest versions of each component are updated and identified Facility Commander Wnx installation begins and the Welcome window opens Continue with Facility Commander Wnx software installation begins below Facility Commander Wnx software installation begins Note A Cancel button displays on every FCWnx installation window If you click Cancel at any time during the installation the FCWnx installation process stops but all Windows components that have been installed must be manually removed To install the Facility Commander Wnx application 1 The Facility Commander Wnx Welcome window opens Click Next 2 When the License Agreement window opens select accept the license agreement and click Next FCWnx 7 7 Global Edition Installation M
305. stom installations 64 FCWnx 7 7 Global Edition Installation Manual Chapter 3 Installing Facility Commander Wnx Global configuration Windows 2003 or Windows 2008 Server operating system Note Prerequisite Database server installation and file server installation already complete To install the FCWnx client application on the second computer using Windows 2003 or 2008 1 2 Verify that the computer you are configuring meets minimum requirements If not already done install the Windows 2003 or Windows 2008 operating system but do not install Microsoft SQL You must be logged in as administrator user to the domain If not log off and log back on as a user with administrator permissions 4 Insert the Facility Commander Wnx installation disc into the CD DVD drive 5 When the AutoPlay window opens click Run SETUP EXE 6 When Facility Commander Wnx starts click Install If the disc does not launch you must manually start the software Using Windows Explorer navigate to the FCWnx Installation disc and double click Setup exe A series of windows open as the listed components install Answer the prompts as appropriate and continue This takes several minutes e NET Framework Windows Installer Installing non English operating systems During installation the installation process checks your system for minimum required components If the following Microsoft Windows components are not detected installation is
306. switch settings They should be set to the default settings To install FCWnx Burle Allegiant 1 You must be logged in to the FCWnx computer with administrator privileges If not log out and log back in Note The client on which you are installing FCWnx must be able to communicate on the network with the FCWnx server computer Appendix C CCTV Interfaces 2 Click Start then Run 3 From the Run window click Browse 4 Inthe Look in field select the hard drive on which FCWnx is loaded such as C Then navigate to the directory in which FCWnx is installed The default is Program Files GE FCWnx Select the CCTVInstall exe Click Open In the Run window click OK Oe Se SODAN Provide the appropriate answers to prompts and click Next to continue During installation you are prompted with a few questions e Type of CCTV Interface Select Burle Allegiant e Description or name for the interface Enter a description for this interface such as Main Building CCTV Note If multiple same type CCTV interfaces are installed on a single FCWnx network the description of each interface must be unique e COM port to which this interface is connected Select the COM port e COM port for video loss signal OPTIONAL Select a COM port to use as a second connection for the interface Click Next 9 Click Install to complete the installation You need to stop and restart the FCWhnx server for these changes to take effect
307. system check is finished click Next to continue 9 The Windows Installer window opens briefly No user action is required 10 The Microsoft SQL Server Installation window opens a progress bar as setup is preparing to continue with the installation No user action is required 11 The Registration Information window opens as shown in Figure 3 FCWnx 7 7 Global Edition Installation Manual 19 Chapter 2 Windows Server 2003 2008 Standard and Enterprise Edition Server setup Figure 3 Registration Information j Microsoft SQL Server 2005 Setup Registration Information The Following information will personalize your installation 12 Enter a name company and the 25 character Product Key found on the yellow sticker in the CD liner notes or the CD sleeve Verify your entry and click Next 13 The Components to Install window opens as shown in Figure 4 20 FCWnx 7 7 Global Edition Installation Manual Chapter 2 Windows Server 2003 2008 Standard and Enterprise Edition Server setup Figure 4 Components to Install j Microsoft SQL Server 2005 Setup Components to Install Select the components to install or upgrade J Greate a SQL Server Failover cluster J Greate an Analysis Server Failover cluster Reporting Services 14 Select the following items and then click Next e SQL Server Database Services e Workstation components Books Online and development tools 15 The Instance Name w
308. t 2 When the License Agreement window opens select accept the license agreement and click Next 3 Select the type of installation as Custom and click Next The Custom Configuration window opens as shown in Figure 109 Select File Server Figure 109 FCWnx Global custom configuration file server i Facility Commander Wnx 7 7 Setup S loj xj FCVvnx Global Custom Configuration O Choose the appropriate components for a custom Global Edition installation i I Database Server Choosing this option will install the FC W nx database components Please select which type of server C Global Only one of these per FCWnx Global Edition installation Regional There can be several of these for an FCWnx Global Edition installation IV File Server z Choosing this option will install the FCwnx File Server components I FCWnx Client Application Choosing this option will install the FC Wnx Client Application Wise Installation Wizard 4 Click Next The Change the Secure password window opens The Facility Commander Wnx installation creates a new Windows User ID called secure By default the password is SecurityMaster08 case sensitive If your Windows network has security policies that enforce rules for password creation you may need to change the secure user password If you are unsure ask your system administrator Select one of the following e Use Default Password Change Password If you sele
309. t Global Database Server field select the Global database server for this Regional database server 164 FCWnx 7 7 Global Edition Installation Manual Chapter 4 Install Global Edition Regional configuration Figure 97 Create FCWnx database Select database server type Select Database Server Type d Efe x FCWnx Database Select the database installation option from the list below Global Database Server This option will install a Global Database Server and Distributor SQL Server must already be installed with an instance of SPSQL A z This option will install the Regional Database Server Regional Database Server on a local client A Distributor must be selected from ist below Select Global Database Server GLOBAL32BIT SPSQL 2 Click Next The Create Convert Database window opens as shown in Figure 98 Ignore the sa User Name as displayed The Password field displays your previously assigned and encrypted SQL password If you purchased your Facility Commander Wnx system from UTC Fire amp Security a temporary password of SecurityMaster08 case sensitive was assigned for you Accept the password as displayed FCWnx 7 7 Global Edition Installation Manual 165 Chapter 4 Install Global Edition Regional configuration Figure 98 Create Convert Database 3 166 Create Convert Database FCWnx 7 7 Database Collect login information To begin the database create convert process please su
310. t accesses and completes the registration for the first time is the license controller computer The license key is stored on the File server computer therefore the first licensed computer AND File server computer must be online when services are started and the newly licensed client is brought online for the first time 12 If you do not enter a license key then Facility Commander Wnx will run in Demo Mode with only limited functionality Refer to Running in demo mode on page 229 Note A summary of your license displays in the About window of Facility Commander Wnx Refer to About Facility Commander Wnx license summary on page 232 for additional details 13 Following the licensing sequence you must return to your installation sequence Unless otherwise instructed you are ready to set services Refer to Setting Services to Automatic Startup in the section of this manual pertaining to the operating system you are installing 228 FCWnx 7 7 Global Edition Installation Manual Chapter 6 License and Set Security Settings for your FCWnx System Running in demo mode Clicking Cancel during the first licensing session When the License Setup window opens during the installation sequence the option to Cancel can be selected Installation of this application completes and operation of your system continues in Demo Mode until you properly license your system In Demo Mode the system periodically shuts down and you are
311. talling 294 Contacting technical support 298 FCWnx 7 7 Global Edition Installation Manual 293 Chapter 13 Troubleshooting maintenance support Troubleshooting This section provides information to help you diagnose and solve various problems that may arise while configuring or using your UTC Fire amp Security product and offers technical support contacts in case you need assistance See Contacting technical support on page 298 Installing FCWnx Symptom A message displays similar to the following Some programs will not install correctly if you do not have administrative privileges on this computer Solution You are logged in as a user who does not belong to the Administrators group The FCWnx software can only be installed by a user who belongs to the Administrators group Log off then log on as a user who belongs to the Administrators group or add the user to the Administrators group Database creation errors Symptom A message displays similar to the following Figure 161 Database creation error FCWnx Database E xj s Fc Wnx Database has been created with errors Please check the error log For details Solution Review the CreateDatabaseLog error log and correct any installation configuration problems e If you were able to resolve the problem recreate the database e If you continue to have a problem contact UTC Fire amp Security Customer Support Installing and uninstalling Uninstalli
312. te Proceed to Licensing your Facility Commander Wnx system below if you have not already licensed Licensing your Facility Commander Wnx system To license your Facility Commander Wnx system at this time After obtaining your registered license key as instructed in Chapter 6 License and Set Security Settings for your FCWnx System on page 225 follow one of the sequences listed e First time license on page 227 e Running in demo mode on page 229 e lf you do not license during the Facility Commander Wnx installation sequence on page 230 Note When you have completed a successful licensing sequence return to this point and continue After a successful licensing sequence or if you click Cancel to license at another time 1 You may receive a Facility Commander Wnx Installation Complete dialog box If so click Yes to restart your computer 2 Log on as administrator and continue with Setting services to automatic startup on page 188 Configuring security settings The Security Configuration utility launches immediately following the License Setup and assists you in configuring firewall and DCOM settings on your computer Check with your IT department for company specific network settings Refer to SecurityCnfg Utility on page 234 for more details on using this utility After successfully configuring the security settings 1 You may receive a Facility Commander Wnx Installation Comple
313. te Remember to change the client name in the Facility Commander Wnx application Client table Re creating a Microsoft SQL Server registration This step changes the computer name for the Microsoft SQL Server program Microsoft SQL Server 2005 2008 To change the computer name in Microsoft SQL Server 2005 2008 1 g amp ON Click Start Programs Microsoft SQL Server 2005 or 2008 and then SQL Server Management Studio At the Connect to Server dialog connect to your SPSQL instance Select then right click your computer name and SPSQL instance Select Register In the server name field enter the new name of the server computer and then click Save Figure 159 Register Server oF Register Server xj Server You can replace the registered server name with a new name and optional server description Server name Server description Server Group Select a server group LJ Database Engine New Group coe __ FCWnx 7 7 Global Edition Installation Manual 275 Chapter 9 Logging on and configuring Facility Commander Wnx 8 9 Enter the sa login name and sa password Do not change any other selections Click the Server drop down list to display the list of server names in your Facility Commander Wnx network system Your newly created server name should display on this drop down list Select your new server name Select Connect The password fields are now
314. te dialog box If so click Yes to restart your computer FCWnx 7 7 Global Edition Installation Manual 187 Chapter 4 Install Global Edition Regional configuration 2 Log on as a domain administrator and continue with Setting services to automatic startup below Setting services to automatic startup Now you need to change the startup method of the FCWnx services to automatic This means every time the computer starts the Facility Commander Wnx services start Refer to Facility Commander Wnx services overview on page 266 for additional information about Facility Commander Wnx Services Note At this point in the installation the Facility Commander Wnx services are stopped Setting services to automatic startup Now you need to change the startup method of the FCWnx services to automatic This means every time the computer starts the Facility Commander Wnx services start Refer to Facility Commander Wnx services overview on page 266 for additional information about Facility Commander Wnx Services Note At this point in the installation the Facility Commander Wnx services are stopped To set the startup method of Facility Commander Wnx Services 1 Click Start Control Panel Administrative Tools and then Services The Services window displays as shown in Figure 113 Expand the list of services and scroll down 188 FCWnx 7 7 Global Edition Installation Manual Chapter 4 Install Global Edition Regional co
315. that enforce rules for password creation you may want to change the Secure user password If you are unsure ask your System Administrator Use Default Password C Change Password New Password eeeeeececeeereeee Repeat New Password seeeeeeeeeeereee Wise Installation Weard 5 Click Next The Ready to Install the Application window opens 6 Enter the SQL Server password for the sa user This password was previously created during installation of SQL Refer to Installing Microsoft SQL Server on page 17 7 The default Destination Folder is indicated You may want to install to another location Click Browse to navigate to the program folder of your choice for placement of Facility Commander Wnx files 8 Click Next to continue Facility Commander Wnx copies system files updates the system configuration and displays the Facility Commander Wnx icon on your desktop This may take a few minutes 9 When the Facility Commander Wnx has been successfully installed window opens click Finish 10 If your computer restarts log on and continue Creating the database custom installation To create the database 1 The Select Database Server Type window opens as shown in Figure 89 Select Regional Database Server and in the Select Global Database Server field select the Global database server for this Regional database server 154 FCWnx 7 7 Global Edition Installation Ma
316. the Digital Video Surveillance option increasing the processor speed and memory may be required to increase performance in your specific system Software Server and client The following table lists the supported operating system software requirements and configurations for Facility Commander Wnx 7 7 Global Edition Note The Domain computer must be running Server 2003 R2 or later operating system Table 1 Global edition software requirements Windows Server OS Window Client OS Server database Server 2003 R2 32 bit XP Pro SP3 32 bit SQL Server 2005 SP3 32 bit upgrades only Vista SP2 32 bit Win7 32 bit Server 2008 SP2 32 bit XP Pro SP3 32 bit SQL Server 2008 SP1 32 bit Vista SP2 32 bit Vista SP2 64 bit Win7 32 bit Win7 64 bit Server 2008 SP2 64 bit XP Pro SP3 32 bit SQL Server 2008 SP1 64 bit Vista SP2 32 bit Vista SP2 64 bit Win7 32 bit Win7 64 bit Server 2008 R2 64 bit XP Pro SP3 32 bit SQL Server 2008 SP1 64 bit Vista SP2 32 bit Vista SP2 64 bit SQL Server 2008 R2 Win7 32 bit Win7 64 bit FCWnx 7 7 Global Edition Installation Manual 3 Chapter 1 Introduction to Facility Commander Wnx e NET Framework 3 5 SP1 Note If NET Framework 3 5 is installed on your system it must be uninstalled before you upgrade to NET Framework 3 5 SP1 e Windows Installer 4 5 e Recommended Ability for remote Internet access support Integrated video management Due to the demanding nat
317. the Global database instance Refer to Figure 19 on page 42 4 The Facility Commander Wnx Merge Publication is defined To define a publication the database to be replicated is selected Within that publication articles are defined The articles are representative of the tables contained within the database FCWnx 7 7 Global Edition Installation Manual 75 Chapter 3 Installing Facility Commander Wnx Global configuration 5 After the Publication is defined the initial Snapshot Agent is started This Agent will create an image of the database at that moment in time Subscribers will utilize this snapshot later 6 The SecurePerfectGlobalHistory database is created This database is only present in the Global database server of a Global Edition installation The following history tables are contained within AlarmHistoryTable BadgeHistoryTable DlHistory DOHistory DVMRHistory GuardTourHistory OperatorHistoryTable SecureAreaHistory ZoneHistoryTable 5 A message opens FCWnx Database successfully created Note A log file is created when the Create Database program is run The log file called CreateDatabaseLog is found in the Logs folder The Integrity utility runs automatically following a database creation No user interaction is required Refer to your Facility Commander Wnx Online Help for addition information about the Integrity utility 6 Click OK The dialog box closes If you receive a message to restart at thi
318. the database snapshot taken by the Snapshot Agent to the Regional 5 database A schedule is updated to operate every day every one minute and set to run As records are added deleted or updated on Regional Servers or the Global database server the changes are replicated to all database Subscribers A new history transactional publication is created on the Regional database server The name of the publication will be similar to the following SecurePerfectHistory SPHistoryPublication A subscription to this publication is created 6 on the Global database server The name of this subscription is Global servername SPSQL SecurePerfectHistory Each Region s history is replicated to the Global database server but it does not redistribute Regional data to another Region History data is a one way replication A new push subscription is created on the Region a snapshot is started and the Transactional Agent is run Note For each history publication on the Regional server there is a corresponding subscription on the Global server while the SecurePerfect database publication has multiple subscribers 5 A message opens FCWnx Database successfully created Note A log file is created when the Create Database program is run The log file called CreateDatabaseLog is found in the Logs folder The Integrity utility runs automatically following a database creation No user interaction is required Refer to your Facility Commander
319. the name of the client computer Press Enter If the ping was successful the client computer address was reached Your window will display similar to Figure 142 Successful ping to client computer 220 FCWnx 7 7 Global Edition Installation Manual Chapter 5 Configuring Global Edition for file replication Proceed to add the clients to the database Refer to Adding clients to the database on page 222 Figure 142 Successful ping to client computer es C WINNT System32 cmd exe iC gt ping BCTBOGOTA Pinging BCTBOGOTA 3 18 145 104 with 32 bytes of data Reply from 3 18 145 bytes 32 time lt i ms TTL 128 Reply from 3 18 145 bytes 32 time lt i ms TTL 128 Reply from 3 18 145 bytes 32 time lt i ms TTL 128 Reply from 3 18 145 bytes 32 time lt i ms TTL 128 Ping statistics for 145 104 Packets Sent 4 Received 4 Lost x loss Approximate round trip times in milli seconds Minimum ms Maximum ms Average Gms C N If the ping was unsuccessful ping the client computer could not be reached Your window will display similar to Figure 143 Unsuccessful ping to server computer Verify your network settings as configured during the operating system setup on Configuring the computer for the network on page 10 fora Windows 2003 or 2008 Standard Server or Installing the operating system on page 242 for a Professional Server or contact your network administrator for assistance
320. ting a database outside of the normal installation sequence To create the database 1 Click Start Programs Facility Commander Wnx and then Create FCWnx Databases A Select FCWnx Edition window opens 2 Select Global Edition as the appropriate Facility Commander Wnx software Edition installed on your computer from the drop down list and then click Next A Select Database Server Type window opens as shown in Figure 63 Select Global Database Server and then click Next FCWnx 7 7 Global Edition Installation Manual 115 Chapter 3 Installing Facility Commander Wnx Global configuration Figure 63 Create FCWnx database Select database server type Select Database Server Type FCWnx Database Select the database installation option from the list below ta A This option will install a Global Database Server and Global Database Server Distributor SQL Server must already be snstelled with an instance of SPSQL This option wil install the Riyionel Database Server C Regional Database Server on a local client A Distributor must be selected from ist below Select Global Database Server l 3 The Create Convert Database window opens Figure 64 Create database Global database server amp Create Convert Database FCWnx 7 7 Database Collect login information Q To begin the database create convert process please supply the SQL Server SQL 2008 Express administrators username and passw
321. tion _ ___ __ C Program Files GE FCWnx Database ae Log File Directory ram Filas GE FCWnx Database View Integrity Report cok e gt oee 4 Click Create Database The database creation begins and a progress bar is displayed This may take a few minutes Caution If a database already exists a warning message will display stating that you are about to overwrite your existing database with an empty default database Order of events Regional database server database creation For information only this is the order of events taking place during the Regional database server database creation No action is required on the part of the user Table 18 Order of Events Regional database server database creation Step Description The Regional database server database is created SecurePerfect 1 SecurePerfectHistory and SecurePerfectArchive The Regional database server contacts the SecurePerfectDistributor and Publisher on the Global database server The Regional database is added to the Subscriber s list at the Publisher and a new push subscription is created The Snapshot Agent is started at the Global Database server computer When the 4 agent completes the snapshot of the Global database the snapshot is applied to the Regional database server database FCWnx 7 7 Global Edition Installation Manual 167 Chapter 4 Install Global Edition Region
322. tion to choose which application features you want z installed and where they will be installed Recommended for p advanced users wise Installation wizard Click Next The Install Facility Commander Wnx Client Server window opens When asked Is this computer part of a Facility Commander Wnx Global Edition installation select Yes 6 Click Next The FCWnx Global Custom Configuration window opens as shown in Figure 83 Check the check box for only FCWnx Client Application FCWnx 7 7 Global Edition Installation Manual 147 Chapter 4 Install Global Edition Regional configuration Figure 83 FCWnx Global Custom configuration FCWnx Client Application Facility Commander Wnx 7 7 Setup SS ioj x FCVvnx Global Custom Configuration O Choose the appropriate components for a custom Global Edition installation lt I Database Server Choosing this option will install the FCW nx database components Please select which type of server Globe Only one of these per FCWnx Global Edition installation Regional There can be several of these for an FCWnx Global Edition snstallot I File Server Choosing this option will install the FCWnx File Server components IV FCWnx Client Application Choosing this option vall install the FCWnx Client Application Wise Installation Wizard Cne 7 Click Next The Database and File Server Paths window opens as shown in Figure 84 Database and FileServer Paths
323. tiple sites to keep copies of the same data This is useful when multiple sites need to read the same data or need separate servers for reporting applications e Distributing copies of data on a scheduled basis e Working with copies of data while disconnected and then propagating changes to another database when they are connected Bringing data closer to individuals or groups This helps to reduce conflicts based on multiple user data modifications and queries because data can be distributed throughout the network and you can partition data based on the needs of different business units or users e Synchronization of data by implementing a customized replication configuration We recommend that you review Figure 19 on page 42 and Global configuration definitions on page 43 for a greater understanding of the replication features before you begin your configuration process e Replication is one choice for customized standby server strategy For more information refer to Installing Facility Commander Wnx in a Clustered Environment on the Documentation disc shipped with your Facility Commander Wnx system Sample configuration overview Figure 19 on page 42 shows a typical Facility Commander Wnx Global system configuration This figure will be referenced throughout this topic as we explain how to set up the system FCWnx 7 7 Global Edition Installation Manual 41 Chapter 3 Installing Facility Commander Wnx Global configuration Fi
324. to all user accounts This will avoid security permission issues when attempting to access remote client computers Refer to your Windows 2003 or Windows 2008 Server documentation for additional information on setting up a user and assigning passwords FCWnx 7 7 Global Edition Installation Manual 11 Chapter 2 Windows Server 2003 2008 Standard and Enterprise Edition Server setup Windows 2003 Server You will be asked to select a file system type For added security we recommend that you select NTFS On the Licensing Modes screen select Per server Windows 2008 Server You will be asked to select a file system type For added security we recommend that you select NTFS By default the Password Policy is enabled You will be asked to change the Administrator password after installation of Windows 2008 Server For additional information consult your Microsoft documentation Setting up your monitor The minimum recommended monitor resolution required for Facility Commander Wnx is 1024 by 768 Small Fonts must be selected on the General tab of the Advanced properties If using Imaging the minimum color resolution is High Color 16 bit To access the display settings Right click your mouse on the desktop Select Properties from the menu Click the Settings tab in the Display Properties window Change the Screen resolution to at least 1024 by 768 pixels Change the Color quality to at least 16 bit if using imaging Click A
325. to the Facility Commander Wnx logs FCWnx 7 7 Global Edition Installation Manual Chapter 3 Installing Facility Commander Wnx Global configuration Figure 39 Create Database Initialize the database creation P create Database nx FCWnx 7 7 Database Initialize the database creation Q View Error Log m Database Directory r area a I TMM GE FCWnx Database m Log File Directory C Program Files GE FCWnx Database at View Integrity Report cok e gt ooe 4 Click Create Database The database creation begins and a progress bar is displayed This may take a few minutes Caution If a database already exists a warning message will display stating that you are about to overwrite your existing database with an empty default database Order of events Global database server database creation For information only this is the order of events taking place during the Global Database creation No action is required on the part of the user Table 9 Order of Events Global database server database creation Step Description 1 The Global database server databases are created SecurePerfect SecurePerfectHistory and SecurePerfectArchive 2 The SecurePerfectDistributor database is installed and enabled 3 The Global database server is configured for publishing The Publisher is identified by the Global database instance name In this installation scenario there is only one Publisher on
326. trator and installation continues e NET Framework Windows Installer Note On rare occasions when installing Facility Commander from a DVD drive the installation will stall for approximately 10 to 20 minutes from the time you click Install to the time when the Welcome to Facility Commander Wrx 7 7 Installation Wizard page opens If this occurs it is most likely caused by your anti virus software If you have anti virus software running you must FCWnx 7 7 Global Edition Installation Manual 103 Chapter 3 Installing Facility Commander Wnx Global configuration configure it so that the DVD drive is not scanned Refer to the documentation that came with your anti virus software for details 7 The Facility Commander Wnx installation processes updates on your system When the latest versions of each component are updated and identified Facility Commander Wnx installation begins and the Welcome window opens Continue with Facility Commander Wnx software installation begins on page 66 Facility Commander Wnx software installation begins Note A Cancel button displays on every FCWnx installation window If you click Cancel at any time during the installation the FCWnx installation process stops but all Windows components that have been installed must be manually removed To install the FCWnx client application on the third computer 1 The Facility Commander Wnx Welcome window opens Click Next The License Agreement window
327. ts minimum requirements 2 If not already done install the Windows 2003 or Windows 2008 operating system but do not install Microsoft SQL 3 You must be logged in as administrator user to the domain If not log off and log back on as a user with administrator permissions 4 Insert the Facility Commander Wnx installation disc into the CD DVD drive 5 When the AutoPlay window opens click Run SETUP EXE 6 When Facility Commander Wnx starts click Install If the disc does not launch you must manually start the software Using Windows Explorer navigate to the FCWnx Installation disc and double click Setup exe A series of windows open as the listed components install Answer the prompts as appropriate and continue This takes several minutes e NET Framework e Windows Installer 182 FCWnx 7 7 Global Edition Installation Manual Chapter 4 Install Global Edition Regional configuration Installing non English operating systems During installation the installation process checks your system for minimum required components If the following Microsoft Windows components are not detected installation is halted e NET Framework A popup message opens informing you that installation will be cancelled until you install the required software in the appropriate language to the operating system you are installing You cannot install Facility Commander Wnx until this is accomplished The following components cause the system t
328. tton Enter the Domain server name and then click OK Note A valid domain administrator userid and password is required to add the computer to the domain 6 Restart the server FCWnx 7 7 Global Edition Installation Manual 15 Chapter 2 Windows Server 2003 2008 Standard and Enterprise Edition Server setup Defining user accounts The Users and Passwords selection in Control Panel allows you to add users to your computer and to add users to a group In Windows 2003 and Windows 2008 permissions and user rights are usually granted to groups By adding a user to a group you give the user all the permissions and user rights assigned to that group During installation of the FCWnx application the user group SPAdmin is created Users must be a member of the SPAdmin group to perform most of the tasks necessary to operate the FCWnx system The user secure is automatically created during installation and is part of the Users and SPAdmin group by default Adding users is optional but recommended since this clearly identifies each user in Windows Note If you do choose to add additional users you must assign them to the group SPAdmin 16 FCWnx 7 7 Global Edition Installation Manual Chapter 2 Windows Server 2003 2008 Standard and Enterprise Edition Server setup Installing Microsoft SQL Server Note If you purchased this system from UTC Fire amp Security SQL Server is installed and configured for you The SQL Se
329. tware on additional clients by your anti virus software If you have anti virus software running you must configure it so that the DVD drive is not scanned Refer to the documentation that came with your anti virus software for details 4 The Facility Commander Wnx installation processes updates on your system When the latest versions of each component are updated and identified Facility Commander Wnx installation begins and the Welcome window opens Continue with Facility Commander Wnx software installation begins below Facility Commander Wnx software installation begins Note A Cancel button displays on every FCWnx installation window If you click Cancel at any time during the installation the FCWnx installation process stops but all Windows components that have been installed must be manually removed To install Facility Commander Wnx software on additional client computers 1 The Facility Commander Wnx Welcome window opens Click Next 2 During installation provide the appropriate answers to prompts as they display 3 When the License Agreement window opens select accept the license agreement 4 Select Custom Table 24 Selecting an installation type Custom If you need to accomplish any one of the following tasks you must select Custom e If you are installing Facility Commander Wnx Global Edition e If your Facility Commander Wnx database server and file server were installed on one or mor
330. ual 279 Chapter 11 Back up your Global Edition Summary This chapter provides information for system administrators to archive back up and restore the Facility Commander Wnx Global Edition system Content Backup of Global Edition databases 282 Backing up overview 282 Backing up the databases using SQL Server 283 Backing up Facility Commander Wnx folders 285 Backing up the entire Facility Commander Wnx folder 285 FCWnx 7 7 Global Edition Installation Manual 281 Chapter 11 Back up your Global Edition Backup of Global Edition databases Note The following information is an overview of processes for database backup For additional information refer to Microsoft SQL Books Online Caution Remember to back up databases often What is the difference between archiving and backing up Archiving creates a copy of the latest history transactions You will still need to back up the archive file in order to maintain a copy Refer to the Facility Commander Wnx Help System or the Facility Commander Wnx 7 7 User Manual on the documentation disc or details of this function Backing up creates a copy of selected data such as a database or archive and stores it either on the computer or on another media such as tape zip discs CD DVD or a network folder Backing up overview A backup is a copy of selected data Since Facility Commander Wnx does not contain a backup option you can use any method you like to back up the data N
331. ure of streaming video over IP managing multiple video streams from the newly introduced support for SymSuite and VisioWave devices requires increased CPU processing power memory and network bandwidth System wide video performance is equally affected by the resolution frame rate and quality settings of individual video streams and should be adjusted accordingly as supported by the SymSuite and VisioWave devices FCWnx servers and or client workstations used for hosting video devices or viewing multiple video streams should meet the following minimum requirements e CPU Dual processor Dual core or Single processor Quad core at 2 XX GHz or higher e RAM 2 GB or higher e NIC 1 Gb e Video Graphics card hardware support for DirectX 9 with Pixel Shader 3 Before you begin If you received a Facility Commander Wnx system from UTC Fire amp Security your system was licensed according to your purchased items such as number of clients number of readers and number of Imaging clients At this time you are ready to go to Chapter 9 Logging on and configuring Facility Commander Wnx on page 265 4 FCWnx 7 7 Global Edition Installation Manual Chapter 1 Introduction to Facility Commander Wnx Installation and setup outlines Before you proceed make sure that your peripheral system hardware such as controllers readers and network lines is installed and running Once you have completed the installation refer to the document Fac
332. urePerfectHistory An additional selection determines if you are installing Facility Commander Wnx on e Global server computer must have SQL Server already installed There can be only one Global database server e Or the Regional server computer There can be several Regional database servers for a Facility Commander Wnx Global Edition installation File server Only Facility Commander Wnx file server components install This Server stores the data files shared by clients on the Facility Commander Wnx network File shares include graphics images signatures designs and firmware The File Server option is a prerequisite in order to install FCWnx Client Application FCWnx client application Only the FCWnx client application installs Only Facility Commander Wnx client file shares install This includes the FCWnx 7 7 Global Edition Installation Manual Chapter 4 Install Global Edition Regional configuration executable file Facility Commander Wnx services and Facility Commander Wnx DLLs Install to Windows Server Cluster Group Named Does not display in a Global installation If you are seeing this selection click Back review and adjust your selections on the previous Facility Commander Wnx windows Installing in a Cluster environment requires special instructions Refer to installation of cluster technology in the document nstalling Facility Commander Wnx in a Clustered Environment on the Documentation disc shipped with
333. vailable Telephone 855 536 3573 option 5 Email access licenses fs utc com Entering the license key When you have a registered license key it is time to enter the key in FCWnx License Setup at the Facility Commander Wnx Application server computer 1 If the license program is not already open select Start Programs Facility Commander Wnx then FCWnx License A Welcome dialog box displays 2 Click OK to close the dialog box and display the FCWnx License Setup window 3 Continue with the instructions as presented in one of the following scenarios e First time license below Running in demo mode on page 229 e If you do not license during the Facility Commander Wnx installation sequence on page 230 First time license This scenario assumes that this is the first client and this client is licensing during the installation sequence To license the first client 1 The First Time License check box is checked for you Do not change If it is not checked please check it now 2 SQL Password for FCWnx Enter a 12 character password that the application will use to access the FCWnx database By default it is set to the first 12 characters of the Machine Seed Key 3 Select the Warranty Reminder in the Days before Expiration group box and enter or select the number of days before expiration of your warranty that you want a reminder to begin displaying in your application This field accepts a number between 0
334. vileges such as administrator 2 Click Start Control Panel and then Add Remove Programs 3 From the list of currently installed programs that display select Facility Commander Wnx Imaging Runtime 4 Click Remove or Uninstall The Add or Remove Programs window opens asking you to confirm the action Click Yes 5 When uninstall is complete click Finish 6 Repeat steps 3 through 5 for Facility Commander Wnx Crystal Reports Runtime 7 Exit the Add Remove Programs window and the Control Panel Verifying and cleaning up after an uninstall You may encounter problems while uninstalling from a server computer Sometimes this results in an incomplete uninstall which means miscellaneous files are left behind If you did encounter problems the sections that follow detail some troubleshooting steps to assist you in troubleshooting your uninstall The first step is to verify that Facility Commander Wnx uninstalled cleanly Refer to Verifying Facility Commander Wnx uninstalled cleanly below Verifying Facility Commander Wnx uninstalled cleanly Check the Facility Commander Wnx folder and verify that the Database and Logs folders are the only items left To verify a Facility Commander Wnx uninstall 1 Go to Windows Explorer and navigate to your Facility Commander Wnx folder The default setting is Program Files GE FCWnx 2 You should see the Database and Logs folders only If you see any other files select them and click De
335. will be installed Recommended for a i advanced users Wise Installation Wizard 4 Click Next Proceed to Custom installation Regional database server below Custom installation Regional database server Caution This procedure is recommended for experienced software installers only Installing Facility Commander Wnx in a Cluster environment requires special configuration Refer to the document nstalling Facility Commander Wnx in a Clustered Environment on the Documentation disc shipped with your Facility Commander Wnx system in PDF format Caution Installation of Global database server and Regional database servers follow a similar set of instructions Verify that you are installing a Regional database server before you begin 126 FCWnx 7 7 Global Edition Installation Manual Chapter 4 Install Global Edition Regional configuration To begin your custom installation 1 The Installing Global Edition window opens as shown in Figure 67 If this window does not display this computer is not a member of a domain You must be part of a domain to continue 2 When asked Is this computer part of an FCWnx Global Edition installation select Yes and then click Next Figure 67 Installing Global Edition window ji Facility Commander Wnx 7 7 Setup installing Global Edition If you purchased an FCWnx Global Edition license select Yes Select No for any other type of FCWnx license Is this
336. witched on and off The Pelco controller is preprogrammed to interpret these messages To program the Pelco controller refer to the manual on the Pelco command console language Appendix C CCTV Interfaces To add CCTV alarms within FCWnx 1 From the FCWnx Application Group pane select Gateways amp Interfaces then CCTV Interface 2 Click Add 3 In the Description field enter the appropriate description for your system Example Pelco CCTV Alarm 4 Inthe CCTV Interface field choose Pelco 5 Inthe CCTV Alarm field choose the alarm number of the interface you are 8 monitoring The Enable Message and Disable Message fields are automatically selected Use these default settings In the Reset CCTV Alarm field two reset choices for the alarm are provided when the alarm is cleared from the Alarm Monitor or when the alarm Resets This means the Reset or the disable message can be sent out when the FCWnx alarm e Is cleared from the Alarm Monitor or e Resets Click Save To change CCTV alarms within FCWnx 1 4 5 From the FCWnx Application Group pane select Gateways amp Interfaces then CCTV Interface Click Search In the Search Result window locate the CCTV alarm you want to change then select it The alarm information now displays Make the desired changes Click Save To delete CCTV alarms within FCWnx 1 336 From the FCWnx Application Group pane select Gateways amp
337. wn in Figure 31 Select the type of installation as Custom Figure 31 Select Installation type Custom Select installation Type Select the desired installation type Typical The most common application features will be installed This option ar zs is recommended for most users pw a Custom O installed and where they will be installed Recommended for amp Use this option to choose which application features you want ele advanced users Wise Installation Wizard Click Next The Install Facility Commander Wnx Client Server window opens When asked Is this computer part of a Facility Commander Wnx Global Edition installation select Yes 6 Click Next The FCWnx Global Custom Configuration window opens 66 FCWnx 7 7 Global Edition Installation Manual Chapter 3 Installing Facility Commander Wnx Global configuration Check the check box for only FCWnx Client Application Figure 32 FCWnx Global Custom configuration FCWnx Client Application te Facility Commander Wnx 7 7 Setup FC VVnx Global Custom Configuration aS Choose the appropriate components for a custom Global E dition installation I Database Server Choosing this option will install the FOWnx database components Please select which type of server Globe Only one of these per FCWnx Global Edition installation Regional There can be several of these for an FCWnx Global Edition installation I File Server Choosing thi
338. word If you are unsure ask your system administrator Select one of the following e Use Default Password e Change Password If you select this option enter your new password and then enter a second time 5 Click Next The Ready to Install the Application window opens 6 The default Destination Folder is indicated You may want to install to another 160 location Click Browse to navigate to the program folder of your choice for placement of Facility Commander Wnx files Click Next to continue Facility Commander Wnx copies system files and updates the system configuration This may take a few minutes When the Facility Commander Wnx has been successfully installed window opens click Finish Remove the Facility Commander Wnx Installation disc from the CD DVD drive FCWnx 7 7 Global Edition Installation Manual Chapter 4 Install Global Edition Regional configuration 10 You must license your Facility Commander Wnx Global Edition system at this time Return to the computer that has the Facility Commander Wnx client application component installed The License Setup window opens Proceed to license your system at this time Refer to Licensing your Facility Commander Wnx system on page 187 Database server configuration Components Computer 1 Computer 2 Computer 3 Database server v File server v FCWnx client application 4 Note This configuration has the database server installed on Computer
339. x application FCWnx License Refer to the licensing section of this manual for instructions to license your new system The following additional commands are available on machines with Typical Server installed or Custom installation with the database server component installed Create FCWnx database Select this option if you are creating a database OUTSIDE of the normal installation sequence The database creation process is outlined in the appropriate installation section of this manual for your operating system Database Maintenance Utility This menu option opens the database backup restore and password utilities Security Configuration Select this option if you need to set the firewall or security settings OUTSIDE of the normal installation sequence Note The Client menu is detailed in Logging on to client computer on page 260 To open the Facility Commander Wnx client application 1 To access Facility Commander Wnx from your desktop icon double click B ae Facility Commander Winx Access Facility Commander Wnx from the Start menu Click Start Programs then Facility Commander Wnx The Facility Commander Wnx menu displays 2 Select Facility Commander Wnx FCWnx 7 7 Global Edition Installation Manual 269 Chapter 9 Logging on and configuring Facility Commander Wnx 3 The Facility Commander Wnx program starts The Facility Commander Wnx menu bar displays a File and Help menu Log on to access
340. y Commander Wnx Global configuration A message opens FCWnx Database successfully created Note A log file is created when the Create Database program is run The log file called CreateDatabaseLog is found in the Logs folder The Integrity utility runs automatically following a database creation No user interaction is required Refer to your Facility Commander Wnx Online Help for addition information about the Integrity utility 7 Click OK The dialog box closes 8 If you receive a message to restart at this time click Yes to restart log on and continue An FCWnx License Setup window opens Unless otherwise stated in your configuration scenario proceed to Licensing your Facility Commander Wnx system on page 108 Database server and file server configuration Components Computer 1 Computer 2 Computer 3 Database server v File server v FCWnx client application v Note This configuration has the database server and the file server installed on Computer 1 then the Facility Commander Wnx application is installed on Computer 2 Database server and file server on first computer To install the database server and file server on the first computer On the FCWnx Global Custom Configuration window select Database Server Global and File Server FCWnx 7 7 Global Edition Installation Manual 57 Chapter 3 Installing Facility Commander Wnx Global configuration Figure 26 FCWnx Global custom conf
341. y Commander Wnx Global database server 48 Custom configuration options 51 Database server file server and FCWnx client application configuration 52 Database server and file server configuration 57 FCWnx client application on second computer 64 Database server and FCWnx client application configuration 69 Database server configuration 79 FCWnx 7 7 Global Edition Installation Manual 39 Chapter 3 Installing Facility Commander Wnx Global configuration Each component on a separate computer 92 When Global custom configurations are complete 108 Licensing your Facility Commander Wnx system 108 Configuring security settings 108 Setting services to automatic startup 109 Server folder structure 110 Facility Commander Wnx user accounts 113 Adding a new user account 113 Create FCWnx database utility 115 What s next 120 40 FCWnx 7 7 Global Edition Installation Manual Chapter 3 Installing Facility Commander Wnx Global configuration Benefits of Facility Commander Wnx Global configuration We recommend that you review Microsoft SQL Server Merge Replication documentation for detailed information on replication technology software Benefits of Global configuration software solutions include the following e Distributing data changes to other server computers within minutes e SQL clustering with redundant database servers e Does not have a single point of hardware failure e Copying and distributing data to one or more sites Allowing mul
342. y result in damage to the equipment or other property WARNING Warnings identify conditions or practices that could result in equipment damage or serious personal injury Related documentation For more information refer to the following e Facility Commander Wnx Help System Provides reference information such as window and field descriptions along with instructions for system administrator duties such as configuring controllers e Facility Commander Wnx 7 7 Upgrade Manual Provides instructions for upgrading your Secure Perfect or Diamond II system to Facility Commander Wrx 7 7 e M5PXNplus and M2000PXNplus Upgrade Instructions Provides instructions for upgrading to the PXNplus CPU board e M3000 Installation Manual A guide to mounting and installing the M3000 panels and associated boards e Micro 5 Installation Guide A guide to mounting and installing the Micro 5 panels and associated boards FCWnx 7 7 Global Edition Installation Manual v e Micro PX 2000 PXN 2000 and M2000PXNplus Installation Manual This guide provides mounting and installation instructions for the PX 2000 and PXN 2000 microcontrollers e DirecDoor Quick Guide Provides brief instructions on mounting and configuring the DirecDoor controller e Diamond II User Manual This document provides instructions for the installation configuration and operation of the Diamond II software e ACU Networked Intelligent Controllers Hardware Installation Manua
343. y subscribe only to the publications that they need not all of the publications available on a Publisher A subscription is a request for a copy of data or database objects to be replicated A subscription defines what publication will be received where and when Synchronization or data distribution of a subscription can be requested either by the Publisher a push subscription or by the Subscriber a pull subscription A type of replication where the publisher updates all subscriber databases on a schedule with changes from the publisher s databases Preinstallation checklist Note Read this section completely before beginning the installation of the Facility Commander Wnx Global configuration To assist in configuration of your Facility Commander Wnx Global Edition system review this checklist e Prepare and configure your Global system in the order detailed in Installation and setup outlines on page 5 e Each server computer must be part of a domain If you are creating a new domain always consult with the network administrator before adding a domain or adding any computers to an existing network Refer to Adding the computer to a domain on page 15 44 FCWnx 7 7 Global Edition Installation Manual Chapter 3 Installing Facility Commander Wnx Global configuration e For better performance and easy administration we suggest that a new Global User Group be created at the Domain server Active Directory Refer
344. you first set up the system and have confirmed that it is working and any time you upgrade Refer to the Backing up Facility Commander Wnx folders above for specific instructions on backing up to CD DVD RW drives and tape drives FCWnx 7 7 Global Edition Installation Manual 285 Chapter 12 Uninstall Facility Commander Wnx or delete a database Summary This chapter outlines instructions for removal of software and deleting a database Content Uninstalling Facility Commander Wnx software 288 Before you begin 288 Uninstalling a Global configuration system 288 Uninstalling Facility Commander Wnx 289 Uninstalling Facility Commander Wnx installed components 289 Verifying and cleaning up after an uninstall 290 Deleting the database 291 Removing Microsoft SQL Server 291 FCWnx 7 7 Global Edition Installation Manual 287 Chapter 12 Uninstall Facility Commander Wnx or delete a database Uninstalling Facility Commander Wnx software Before you begin Before you uninstall Facility Commander Wnx make sure that All clients are logged off All Facility Commander Wnx applications such as DiagView are closed All Facility Commander Wnx services are stopped Refer to Facility Commander Wnx services overview on page 266 Uninstalling a Global configuration system The sequence of uninstalling a Facility Commander Wnx Global Edition system is a reverse of the installation and enabling process The following instru
345. your Facility Commander Wnx system in PDF format SQL Server must be installed 5 Continue with Custom configuration options below Custom configuration options Caution This procedure is recommended for experienced software installers only The scenarios presented in the custom configurations that follow are the result of selections made on the FCWnx Global Custom Configuration window Review Figure 68 on page 128 Then proceed to the indicated section of this chapter Table 14 Custom configuration options Begin on Scenario page 1 Database server file server and FCWnx client application 130 configuration 2 Database server and file server configuration 138 3 Database server and FCWnx client application configuration 150 4 Database server configuration 161 5 Each component on a separate computer 173 IMPORTANT When you select a scenario be sure to complete all instructions for that scenario Note Some components require that a prerequisite component be installed at another computer before you begin Windows that display during installation are similar to the sample configurations presented FCWnx 7 7 Global Edition Installation Manual 129 Chapter 4 Install Global Edition Regional configuration Database server file server and FCWnx client application configuration Components Computer 1 Computer 2 Computer 3 Database server v File server v FCWnx client applic
346. zard Other Information Browse this CD Visit the SQL Server website Read the SQL Server license agreement Exit 3 When the End User License Agreement window opens review the agreement select accept the licensing terms and conditions and click Next 4 A window displays a list of prerequisites required prior to installing SQL Server Click Install to begin installing the components as shown in Figure 2 Note This process takes several minutes 18 FCWnx 7 7 Global Edition Installation Manual Chapter 2 Windows Server 2003 2008 Standard and Enterprise Edition Server setup Figure 2 Installing Prerequisites I Microsoft SQL Server 2005 Setup E x Installing Prerequisites Installs software components required prior to installing SOL 4 Server i SQL Server Component Update will install the folowing components required for SQL Server Setup Y NET Framework 2 0 Y Microsoft SQL Native Client V Microsoft SOL Server 2005 Setup Support Files The required components were installed successfully Cancel When the process is complete click Next to continue The System Configuration Check window opens This window requires no user action 7 The Welcome to the Microsoft SQL Server Installation Wizard opens Click Next to continue 8 A second System Configuration Check opens Please wait as the system processes a list of potential installation problems Do not change anything on this window When the