1. I Deluxe Digital Syste Electronic Spa Controls Deluxe Digital Control Owner s Manual e microprocessor technology has been combined with solid state electronic switches to produce the Balboa digital control the finest spa control in the world Technologically sophisticated but very easy to understand and use every spa function is conveniently located at your fingertips A backlit highly reliable liquid crystal display gives you a complete update of the spas status at any time of the day or night Temperature setting as well as control of the light jets blower filtration and time of day display are all instantly available from spa side All this and more with the simple touch of a finger Your Balboa digital spa control has been constructed to give years of trouble free service Safety is assured through design concepts and materials which meet or exceed the most stringent requirements of Underwriters Laboratories and other safety agencies Field proven through years of testing and evaluation every feature has been optimized for maximum utilization of your spa Relax and enjoy your spa experience each and every time with the finest spa control in the world from Balboa WARNING This equipment generates and uses radio frequency energy and if not installed and used properly that is in strict accordance with the manufacturer s instruction may cause interference to radio and television reception It has be
2. as the various monitoring functions and programming information FILTER 1 OJ ocr STANDARD Sx ie o nee 3 Owner s Pads E Program function Initiates time setting filter programming and panel lock routines P Mode function H Switches spa operation to either the economy or standard mode In the economy mode the spa will heat only during the filter cycles In the standard mode the preset spa temperature will be maintained This pad also resets the control in the rare instance of an overheat See Center Display Messages Initial Start U p Read and follow all instructions in this manual This control system is designed to be installed by a licensed electrician Refer to the spa manufacturers owners manual for specific instructions When first powered up your spa will be in the economy mode Simply touch B to switch the spa to standard operation and begin heating The spa will heat to 100 F if no other temperature is set Depending upon the size of the spa and heater capacity it should be ready for use in a matter of hours Setting the Time Once the spa has been properly connected notice the set time message flashing on the screen Then Press Then Or After either pad is pressed once hours will advance or decrease automatically in one minute increments Press either pad again to stop the displays time setting cycle to exit the set time procedure Press E Preset Filter Cycle
3. WATER Turn off all power to the spa and contact your dealer or service organization Overheating may also occur if you set the low speed pump to operate for extended periods of time in economy mode In this instance remove the spa cover and allow the water to cool to below 110 E Touch any button to reset the system If the water is still hotter than the set temperature touch the blower pad to cool the spa Sn i Open sensor Spa is shut down The high limit temperature sensor is not working This must be repaired only by a dealer or qualified service organization n Open sensor Spa is shut down The water sensor is not working This also must be repaired by a dealer or service organization Warni ng l Shock Hazard No User Serviceable Parts Do not attempt service of this control Contact your dealer or service organization for assistance Follow all owner s manual power connection instructions Installation must be performed by a licensed electrician and all grounding connections must be properly installed Center Display Messages mom al al LULL Temperature set back If spa water is more than 20 F cooler than the temperature set point the heater will automatically activate to provide freeze protection This is a normal spa function no corrective action is necessary Warning Shock Hazard No User Serviceable Parts Do not attempt service of this control Contact your dealer or service o
4. e displays time setting cycle Press Panel Lock Press E B within 3 seconds When locked the display will show the temperature you have chosen along with the lock symbol All pads are frozen except the Panel Unlock Press Eg to exit the set time procedure S B dihun 2 seconds The lock symbol will disappear and all panel pads will work again Optional Filter Cycle Programming While you are not required to set filter cycles if you want to change them press B R within3 seconds SET START FILTER 1 AM cycle will appear on the display Press GY or B to reset the filter start time When SET HEAT is on the display pres B on to warm the water during filtering or press B off to disable the heater Press J to see SET STOP FILTER 1 and adjust the time with the BY or B as done above Press B to see SET START FILTER 2 PM cycle and proceed as above Pressing B will enter the new filter cycle times into the system and display the current water temperature 11 Balboa Copyright 2000 Balboa Instruments Inc All rights reserved Instruments 2M400 DMI00 Incorporated
5. en type tested and found to comply with the limits for a class B computing device in accordance with the specifications in subpart J of part 15 of the FCC rules which are designed to provide reasonable protection against such interference in a residential installation However there is no guarantee that interference will not occur in a particular installation If this equipment does cause interference which can be determined by turning the equipment on and off the user is encouraged to try to correct the interference by one or more of the following measures Reorient the receiving antenna Relocate the receiver with respect to the spa Move the receiver away from the spa Plug the receiver into a different outlet so that the receiver and spa are on different branch circuits If necessary the user should consult the dealer or an experienced radio television technician for additional suggestions The user may find the following booklet prepared by the Federal Communications Commission helpful How to identify and resolve radio TV interference problems This booklet is available from the U S Government Printing Office Washington DC 20402 Stock No 004 000 00345 4 Welcome to the Balboa Digital Control 1 User s Pads la Temperature controls E When either of these pads are touched once the LCD will display the temperature which has been set as well as the words set heat Each time either of these pads is pressed again
6. our spa panel lock S Mode Switches your spa from economy to standard mode and vice versa The Ultimate Spa Controller Overview Warm up Time Light Sets the temperature of Shows the time of day Turns the light on and off your spa warmer and sets the clock forward Cool down Jets Blower Sets the temperature of Controls the two speed Turns the air blower on your spa cooler and sets pump or off the clock back Alternate Balboa Deluxe Digital Panel Time Liquid Crystal Display Warm up Shows the time of day The Information Center Sets the temperature of of your spa your spa warmer and sets the clock forward mi FILTER 1 HCF STANDARD O W agoes i O05 o aT 9 O Mode Cool down Switches your spa from Sets the temperature of economy to standard mode your spa cooler and sets and vice versa the clock back 10 Blower Turns the air blower on or off Jets Controls the two speed pump Some Deluxe panels may have the button configuration below Light Turns the light on and off Aux for opptional equipment Please refer to your spa manufactures literature Setting the Time Once the spa has been properly connected notice the set time message flashing on the screen Press Then Then After either pad is pressed once hours will advance or decrease automatically in one minute increments Press either pad again to stop th
7. rganization for assistance Follow all owners manual power connection instructions Installation must be performed by a licensed electrician and all grounding connections must be properly installed Freeze Protection While the normal system freeze protection located at the heater is usually adequate certain extreme climates or unique pump configurations may be best served by using an optional external freeze sensor This sensor is attached to a location on the plumbing that a service professional can determine is most prone to freezing Possible locations would be the output plumbing from an auxiliary pump or a section of plumbing that runs near the skirt of the spa This sensor is then connected directly to the control system circuit board and operates in conjunction with the existing system freeze protection i mn LE Freeze protection Ifa freeze condition is detected by any freeze sensor the low speed pump is automatically activated With a multi pump system all pumps will activate This is a normal spa function no corrective action is necessary Freeze protection is enabled regardless of the spas status Note It is recommended that the spa be set in Standard Mode during very cold weather This will keep the water heated to the set temperature and circulated more often Balboa Deluxe Digital Program Liquid Crystal Display For initiating time setting The Information Center filter programming and of y
8. s Now that the time has been set correctly your spa will automatically filter itself for a 2 hour period every 12 hours If your spa has a blower cleanout feature the blower will activate for a short period of time at the beginning of each filter cycle to clean out the air channel Whenever a filter cycle is active this automatic filtering sequence is indicated by the following messages on the LCD screen Filter 1 The first filter cycle is automatically activated at 2 00 AM and operates the low speed of the pump until 4 00 AM The heater will operate in the economy mode Filter 2 The second filter cycle is automatically activated at 2 00 PM and operates the low speed of the pump until 4 00 PM Again the heater will operate in the economy mode Changing Filter Cycles Time of day will be shown Then press F 4 Set time message will appear on LCD Then press Set Start Filter 1 message will appear At this point each time the is pressed the filter start time the heater enable status and the filter stop time will be indicated on the LCD screen If the preset times are inconvenient if a different duration is preferred or if you wish to leave the heater off during filtering the following procedure can be used to change the automatic filter cycle settings When the filter start or filter stop times are displayed on the screen Press am Or 2 to reset the times When the set hea
9. t message is displayed C to set the center display to on or off In the on position the spa will warm to the set temperature during the filter cycles In the off position the heater in the economy mode will not be activated during the filter cycles After entering the filter set routine you must Press M to proceed through all the start and stop times for both filter cycles Just follow the same procedure to adjust the Filter 2 settings To exit the filter set routine Press and the LCD will display the current water temperature Note To properly clean and maintain your spa filtering time of at least four hours per day total of both cycles is recommended Panel Lock To help prevent unauthorized use of your spa the Balboa digital control has incorporated a unique panel locking system When the panellock is engaged all automatic spa functions will operate normally These pads must be pressed within 3 seconds to activate the lock When locked the center display will show the spa temperature along with the lock symbol All the panel pads are now deactivated except the program pad which is used to initiate the unlock sequence Touch or Then P 0 Then E la The display will read 1 Ar L UL Temperature Lock The temperature lock is provided to prevent unauthorized temperature adjustment of your spa water While setting your spa water temperat
10. the set temperature will increase or decrease depending on which pad is pressed After 3 seconds the LCD will automatically display the spa temperature Light Turns light on or off The light will automatically turn off after some period of operation Time Press to view time of day press again to view temperature Current spa temperature display will automatically resume after 3 seconds Jets control i 21 Touch this pad once to activate the low speed of zd the pump Touch again to start the high speed of the pump If the spa has a 2nd pump press the pad a third time and the high speed of pump 2 will also activate Press the pad again and only pump 2 will be operating Press the pad again to deactivate the pump s The low speed of the pump starts automatically when the heater is turned on when a filter cycle is activated or when a freezing condition is detected If automatically activated the low speed of the pump cannot be turned off with the jets pad however the high speed of the pump may be started Whenever the high or low speed of the pump is started with this pad it will automatically stop after some period of operation Blower 9 Starts or stops the blower for aeration in the spa The blower will also automatically stop after some period of operation Your control panel consists of three main parts 2 Liquid Crystal Display Continually shows operating status of the spa as well
11. ure after you have pressed B or E follow the instructions below to lock the set temperature When the temperature lock is engaged all automatic spa functions will operate normally These pads must be pressed within 3 seconds to activate the lock When locked the center display will show the spa temperature the lock symbol and the words set heat The temperature pads B B will be deactivated when pressed the set temperature will appear with a double arrow next to it Touch The display will read LOLF Then M SET HEAT Panel Unlock To unlock the panel these pads must be pressed in the correct sequence and within 2 seconds When the last pad is pressed the lock symbol will disappear All pads are now active Touch Then Then Center Display Messages FLO Flow switch Solid A pressure switch has malfunctioned Contact your dealer or service organization Flow switch Flashing 1 The filter may be plugged Remove the filter and clean 2 The amount of water may be inadequate Be sure the spa is properly filled 3 A pressure switch has malfunctioned The spa will operate but the heater will not activate Contact your dealer or service organization These are some of the messages you may see on the center display UH Overheat protection Spa is shut down Ifa malfunction occurs and spa water reaches 112 F the system will completely shut down In such a condition DO NOT ENTER THE