Home

Microlog CMVA 60

image

Contents

1. OLS S The Microlog CMVA 60 is the newest addition to the SKF line of portable data collectors analyzers With a range of new features and functions the CMVA 60 offers the greatest value yet for your reliability investment Imagine an instrument that not only collects vibration data and performs standard analysis functions but also incorporates on board intelligence to facilitate detection analysis and correction of machine problems The CMVA 60 carries on the tradition established by its predecessor with Wizards embedded intelligence that facilitates critical analysis and correction with minimal setup effort Intuitive menus and preset defaults ensure that all of the commands you need for a specific application are conveniently located and accessible with a single keystroke Wizards make it easy for novices and experts alike to detect analyze and correct machine problems Also new in the CMVA 60 is a downloadable Frequency Analysis Module FAM which automatically overlays not only bearing defect frequencies on a collected spectra but any defect frequency including unbalance misalignment looseness and more This makes identification of bearing and other mechanical structural problems a snap Virtually all you need to perform like a maintenance superstar is at your fingertips with the CMVA 60 While competitors provide teaser capabilities that require the purchase of additional modules or product
2. measurements can be linked for one button push automated data collection for each measurement location DATA DISPLAYS Single or dual split screen magnitude time and phase Digital tracking filter 1x and 2x Amplitude vs degrees and amplitude vs time Motor current analysis zoomed and enveloped e Up to 12 bands fixed or order based downloadable from host software Microlog CMVA 60 Portable Data Collector FFT Analyzer SPECIFICATIONS POWER Battery Size 7 2 V 3 8 AH Long life removable NiMH battery packs No loss of data during battery charges Field and office removable batteries with no tools required Smart charger module APPLICATION RESIDENT PROGRAMS Basic Balancing Wizard Advanced Balancing Wizard Tracking Filter Wizard e Cyclic Analysis Wizard Motor Current Wizard Bump Test Wizard Configuration Wizard Run Up Coast Down Wizard MODES OF DATA COLLECTION Route e NonRoute Analyzer PHYSICAL DATA Keyboard Sealed chemical resistant elastomeric silicon tactile touch e Dedicated Keys Right left up and down arrow right and left handed enter backlight markers on off freeze display zoom in out save data display expand set RPM running frequency index for orders reset measurement LIN LOG and shift cursor e Hot Keys Find peak find last route point measured overall and cursor values motor curre
3. nput Impedance 1 M Ohm Input Coupling Low frequency 3 dB roll off at 0 5 Hz Input Voltage Range AC 25 V peak DC 50 V Dynamic Range 80 dB 14 bit signal conversion plus 60 dB of gain ranging for a total signal input range of 140 dB Amplitude Accuracy within 1 input at one specified frequency Input Connectors BNC 3 input output and tachometer phase and multi pin D connector DATA PROCESSING AND STORAGE Microprocessor Intel 32 bit 25 MHz 4 Tel microprocessor ih side Memory 6 Mb Flash 4 Mb 70 ns in MEASUREMENT Range 0 5 Hz to 20 kHz continuously adjustable Averaging Programmable from 1 to 9 999 e Type Average peak hold synchronous time and off Mode Continuous finite and repeat Markers Fixed and cursor lock Single harmonic relative and sideband Trigger Modes Amplitude trigger thresholds trigger slope and pre and post trigger time delays are fully programmable Free run external and input FFT Analysis Start Frequency Preprogrammed between 0 and the maximum frequency true zoom Maximum Frequency Selected between 1 Hz and 20 kHz Resolution Programmable 100 200 400 800 1600 3200 and 6400 lines Frequency Accuracy 0 01 of the frequency measured at the position of the display cursor Measurement Windows Hanning Uniform and Flat Top Data Collection Rate Up to 5X rate of previous generation data collectors Multi Point Automation Up to 12
4. nt fault criteria and Fmax LCD Screen One button activated backlight 5 000 127mm x 4 375 111mm with replaceable snap on lens cover Case High impact polycarbonate polyester injection molded with IP64 dust and splash rating Size 7 88 W x 10 50 H x 2 50 D 200mm W x 267mm H x 64mm D Weight 5 Ibs 2 3 kg ENVIRONMENTAL CSA C and US Mark Class Division 2 Groups A B C D Similar to EEx nllC Zone 2 CE Mark C EN50081 2 EN50082 2 IP Rating IP64 dust and splash proof Temperature Range Storage 14 F to 140 F 10 C to 60 C Temperature Range Operating 14 F to 122 F 10 C to 50 C Humidity 95 non condensing COMMUNICATIONS Communication 1200 2400 4800 9600 19200 38400 57600 and 115 200 baud rates and ability to input modem commands PRINTING LaserJet or Dot Matrix 8 5 x 11 0 and A4 metric formats CMSS 6160 Printer Adapter must be used The following printers have been tested for Microlog CMVA 60 compatibility H P Models LaserJet Ill 4 4 Plus 5L 5N 6L 2100SE 4000 and 4000N e Epson Models Stylus Color 440 Stylus Color 740 Stylus Color 900 LQ50 and LQ510 Canon Models Bubble Jet BJC 620 NEC Models 1260 Super Script See SKF Condition Monitoring website for complete list of supported printers ORDERING INFORMATION Standard Kit CMVA 60 Microlog Data Collector FFT Analyzer Single Channel CMVA 6112 CE Micr
5. olog Support Module CMVA 50230 4 Battery Pack NIMH Spare CMVA 3355 AC DC Adapter Universal 115V 230V CMVA 3351 Cable Power Cord For CMVA 3355 UL110 CMVA 6131 Microlog Carrying Case Nylon Black CMSS 50077A CE Cable Microlog to Support Module 4 feet CMSS 50080 CE Cable Support Module to PC 4 feet CMAC 4301 BOV Adapter CMSS 50079 CE Cable Microlog to BNC No Power 5 feet CMSS 2200 Accelerometer CMSS 31707500 CE Cable Microlog to CMSS 2200 Accelerometer CMSS 60139 04 Stinger Accelerometer Tip 4 5 inches CMSS 908 MD Magnetic Base Accelerometer 1 5 inches 31641400 Installation and Implementation of Portable Condition Monitoring Programs 31788700 Flash Code Disk CM F 0072S Machinery Data Sheets 25 Sheets CM F 0077 Literature Using Machinery Data Sheets 31824600 Microlog Standard Languages User Manual and Firmware on CD ROM Optional Kits CSA Non incendive Kits Available Although care has been taken to assure the accuracy of the data compiled in this publication SKF does not assume any liability for errors or omissions SKF reserves the right to alter any part of this publication without prior notice SKF is a registered trademark of SKF USA Inc Intel Inside is a registered trademark of Intel Corporation CM2255 Revised 4 00 Copyright 2000 by SKF Condition Monitoring Inc ALL RIGHTS RESERVED SKF Condition Monitoring Area Centers Europe Middle East Africa Po
6. s to actually utilize the function the CMVA 60 provides it all in a single package What does this mean to you The power to dramatically improve your plant s reliability efforts while maintaining your budget For additional information on the Microlog CMVA 60 contact your local SKF Condition Monitoring Sales Representative or visit our web site at www skfcm com Microlog CMVA 60 Portable Data Collector FFT Analyzer SKF Condition Monitoring SPECIFICATIONS INPUT SOURCES Acceleration Velocity and Displacement from hand held or installed sensors or monitoring systems SEE Sensor CMSS 786M SEE sensor AC DC Current Sensors Pressure Sensors Temperature Sensors Keyboard Entry Measurements read from indicators or installed instruments entered in engineering units Maximum of eight 8 places including sign or and decimal point Universal Tachometer Input Accepts pulse inputs up to 25 volts Visual Inspections Added to measurement as coded notes or in plain language to a total of 32 characters per measurement point PREPROCESSING Hardware Enveloper Demodulator With four 4 selectable input filters for enhanced bearing and gear mesh fault detection Filter Selection 5 Hz 100 Hz 50 Hz 1 000 Hz 500 Hz 10 kHz 5 kKHz 40 kHz INPUT PARAMETERS Tachometer Minimum pulse amplitude 2 volt peak to peak 10 rise fall time minimum 0 1 ms pulse width and conditioning circuitry I
7. stbus 2091 5300 CB Zaltbommel The Netherlands Telephone 31 418 681818 FAX 31 418 681800 North and South America 4141 Ruffin Road San Diego California 92123 USA Telephone 858 496 3400 FAX 858 496 3531 Web www skfcm com Asia Pacific Kawasan Perindustrian Nilai P O Box 26 71807 Nilai Negeri Sembilan Darul Khusus Malaysia Telephone 60 6 799 2713 FAX 60 6 799 2407 Optional Accessories CMAC 4300 Microlog to MARLIN Stud Adapter CMAC 4360 K Triax Accelerometer Kit CMCP 800 01 Microlog Field Balancing Accessory Kit with Optical Sensor CMCP 800 02 Microlog Field Balancing Accessory Kit with Laser Sensor CMAC 4200 SL Infrared Therometer CMIN 400 K Inspector 400 Ultrasonic Probe CMSS 6160 Printer Adapter CMSS TMDT2K Digital Thermometer Kit CMSS 6187 CE Primary Current Clamp Probe 0 60 amps and 0 600 amps AC and DC CMSS 6187 1 CE Secondary Current Clamp Probe 0 20 amps and 0 200 amps AC and DC CMSS 6190L Audio Headphones No special cables required CMSS 6165K 0 CE 115V and CMSS 6165K 1 CE 230V StrobeLite Kits CMSS 6155K 0 W 115V and CMSS 6155K 1 W 230V Optical Phase Reference Kits CMSS 6195K 0 W 115V and CMSS 6195K 1 W 230V Laser Phase Reference Kits CMSS 50401 25 foot 7 5 meters Extension Cable for CMSS 6155 Optical Phase Reference Kit and CMSS 6195 Laser Phase Reference Kits CMSS 6156 Magnetic Holder for CMSS 6155 Optical Phase Reference Ki
8. t and CMSS 6195 Laser Phase Reference Kits CMVA 6132 HD Hard Shell Carrying Case CMSS 6188K High Temperature Accelerometer Kit CMSS 797L Low Frequency Accelerometer CMVA 60LS One 1 Packet with Five 5 Replaceable Snap On Lens Cover PSP051 One 1 Two 2 or Three 3 Year Product Support Plans CERTIFIED iso 9001 Your SKF Condition Monitoring Representative

Download Pdf Manuals

image

Related Search

Related Contents

EW300G3 529661 0109 DE INT    Manual de instalación y operación para los  P-1  Weider WECCSY7409 User's Manual  S120VT (受注生産)(PDF形式、159KB)  Hewlett Packard Enterprise 3TB 6G LFF  Table of Contents - Frank`s Hospital Workshop  Océ 31x5E Configuration and special maintenance  Les Bienfaits de la Graine de Nigelle.pd[...]  

Copyright © All rights reserved.
Failed to retrieve file