Home

User Manual - Affordable Scales & Balances

image

Contents

1. XX PWR means that the auto off function is on XX is the time before the scale will shut off automatically The number is in minutes To continue to other function settings press Unit to confirm the current setting and show the next mode The display will then show OFFbL Onbl or AuTobL these are the backlight function settings 6 3 BACKLIGHT SETTING MODE Press the Tare key to change the state of backlight OFF BL the backlight is off all the time AUTO bL auto backlight backlight will come on if the display moves off of zero Qn bL backlight will be on all the time Press Unit to confirm and move to the next setting When you enter the unit setting mode it will show On Kg or OF Kg 6 4 PARTS COUNTING FUNCTION Press Tare to switch on or off the part counting function QF PCS part counting function is off ON PCS part counting function is on When the part counting function is off in weighing mode press Func key to overleap this function and move to the next setting Press Unit key to confirm the setting and look through the next setting It would enter the percentage weighing when it shows On PER or OFF PER 12 Adam Equipment Company 2008 6 5 PERCENTAGE WEIGHING FUNCTION e Press Tare key to switch on or off this function e CH PER the percentage function is off e ON PER the percentage function if on When the percent
2. the display will show Load then add the selected calibration mass value to the pan e After the calibration mass is added wait for the stable symbol to come on and then press Zero key the display will show PASS and then return to normal weighing after 3 seconds e If itis outside of the previous calibration value by more than 5 it will show FAILL or FALH indicating the new calibration weight was too low FAIL L or too high FAIL H in respect to the previous calibration value 8 0 ERROR MESSAGE ADL A D counts are too low ERR Wrong operation Unit E All the units are disabled Low battery indication 15 Adam Eguipment Company 2008 Adam Eguipment Company 2008 16 CE Manufacturer s Declaration of Conformity This product has been manufactured in accordance with the harmonised European standards following the provisions of the below stated directives Electro Magnetic Compatibility Directive 2004 108 EC Low Voltage Directive 2006 95 EC Adam Eguipment Co Ltd Bond Avenue Denbigh East Milton Keynes MK1 1SW United Kingdom FCC COMPLIANCE This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment The equipment generates u
3. USER CALIBRATION FUNCTION tao sko don pn 13 6 7 SELECTION OF WEIGHING UNITS spin b pr v 13 7 0 CALIBRATION Noc 14 7 1 AUTOMATIC EXTERNAL CALIBRATION j cccsecscsicicccccteteatetasedveasanvascosssateeseees 14 8 0 ERROR MESSAGE dan ensues eei ie A LK ba ik za o bacha 15 Adam Eguipment Company 2008 Adam Eguipment Company 2008 1 0 INTRODUCTION e The LBK models are supplied with a power cord in the case of LBK a models a DC adapter with all models also having rechargeable battery operation e Four models 3kg 6lb 0 5g 0 001lb 6kg 121b 1g 0 0021b 12kg 25lb 2g 0 005Ib 30kg 651b 5g 0 011b e Large LCD with backlight e 5 weighing units g kg Ib oz and Ib oz e Indicators for Stable zero net weight and low battery functions e Stainless steel pan with ABS case and pan support e Sealed Membrane keypad e Overload Protection e Spirit level and leveling feet e Auto calibration zero tracking and tare Adam Equipment Company 2008 Adam Eguipment Company 2008 2 0 SPECIFICATION 1g 0 002Ib 2g 0 0041b 4g 0 011b g kg Ib oz Ib oz Stabilizati Operating 02C to 409C temperature 329F to 1049F LBK models 230V and 6V 4Ah rechargeable battery Power supply LBK a models 12VDC 800mA adapter and 6V 4Ah rechargeable battery Calibration External calibration Calibration 1Kg 2Kg 3Kg or 2Kg 4Kg 6Kg or 4kg 8kg 12kg or 10kg 20kg 30kg or Weights 21b Alb
4. 2000 certified global company with more than 35 years experience in the production and sale of electronic weighing equipment Adam products are predominantly designed for the Laboratory Educational Medical retail and Industrial Segments The product range can be described as follows Analytical and Precision Balances Compact and Portable Balances High Capacity Balances Moisture analysers balances Mechanical Scales Counting Scales Digital Weighing Check weighing Scales High performance Platform Scales Crane scales Medical Scales Retail Scales for Price computing For a complete listing of all Adam products visit our website at www adamequipment com Copyright by Adam Equipment Co Ltd All rights reserved No part of this publication may be reprinted or translated in any form or by any means without the prior permission of Adam Equipment Adam Equipment reserves the right to make changes to the technology features specifications and design of the equipment without notice All information contained within this publication is to the best of our knowledge timely complete and accurate when issued Hovvever we are not responsible for misinterpretations which may result from the reading of this material The latest version of this publication can be found on our Website www adamequipment com 18 Adam Equipment Company 2008
5. 6lb 4lb 8lb 121b 10lb 20lb 25lb 20lb 40lb 60lb LBK 3 6a LBK 6 12a LBK 12 25a LBK 30 65a Display 6digit LCD display green backlight LBK a models are supplied to North and South American markets only and are available from Adam Eguipment USA office Adam Eguipment Company 2008 3 0 SAFETY PRECAUTIONS Caution Please use only the original power cord or DC adapter supplied with the scale Other cords or adapters may damage the scale Notice SS4 0 Avoid extremes of temperature Do not place in direct sunlight or near air conditioning vents Battery should be removed if the scale is not used for a long period of time Do not stack material on the scale when it is not in use Avoid high humidity that might cause condensation and keep away from direct contact with water Static may influence the weighing result To reduce the static wipe the pan and the scale with anti static wipes SET UP 4 1 ASSEMBLING OF SCALE Put the scale on a stable and even table Adjust the height of the feet to level the scale the spirit level bubble should be in the center of the spirit level Put the pan support in place inserting the pan support pins into the holes on top of the scale Place the stainless steel pan on the support Don t press the scale with great force or the load cell could be damaged Adam Equipment Company 2008 4 2 ASSEMBLING OF BATTERY AND POWER In some cases the recha
6. EES ADAM Adam Equipment LBK SERIES P N 9596 Revision C1 December 2008 Adam Equipment Company 2008 Easy Reference Model name of the scale I Serial number of the unit NENNEN Software revision number Displayed when power is first turned on Date of Purchase Name of the supplier and place Adam Equipment Company 2008 Adam Eguipment Company 2008 CONTENTS 1 0 INTRODUCTION Mresemmscm ce 4 2 0 SPECIFICATION irri ei ek a souvascasavaticasivenicasavsniaasevviaaasacaniuscenaiaesdevseteasevsniaten 6 3 0 SAFETY PRECAUTIONS 5 iris nsc ya 7 A O SETUP eT 7 4L ASSEMBLING OF SCALE zidy obra EP Rete Der br epe asd Pere ePi eae 7 4 2 ASSEMBLING OF BATTERY AND POWER 2 enero trepidas nies e Phe te anas 8 5 0 idiciIl cp 9 S T BEFORE WEIGHING eir toten n eene da o na kiss 9 Misc ope ERR EN 9 5 3 POUND OUNCE MODEL s 10 54 PARTS COUNTING FUNCTION 45 5 95 cipi ina hl 10 5 5 PERCENTAGE WEIGHING 5 55 irrito husia Pov hp no 11 6 0 FUNCTION SETTING ss s si s sus eaa na d va u Kl aon Coa Ey aru dava eee pain viz 11 6 1 ENTERING THE FUNCTION SETTING MODE hu noie ee trs 11 6 2 SETTING OF AUTO SHUT OFF FUNCTION jvsisensesccecsenecsscupdavcinseapinvenneresantavescens 11 SS BACKLIGHT SETTING MODE sssrin serii O a nn 12 5 4 PARTS COUNTING FUNCTION cncssscisusvesesestetssusetsesiesindontuas Hes vo do on i 12 6 5 PERCENTAGE WEIGHING FUNCTION 22e eere 13 6 6
7. Func key to go to parts counting mode and select the preset sample piece value and add the items to the container as selected and press Zero key e Press Func to exit and go back to the normal weighing mode 10 Adam Equipment Company 2008 5 5 PERCENTAGE WEIGHING e Inthe weighing mode press Func key twice to access the percentage weighing mode the display will show PER e Press Zero key to set the reference sample value the display will show SEL e Place the item to be set at 100 on the pan and press Zero Key when the stability indicator comes on e The display will show 100 0 e When another item with a different weight value is put on the pan the relative value would be shown against the initial reference sample value e Press Func key to exit and go back to weighing mode 6 0 FUNCTION SETTING 6 1 ENTERING THE FUNCTION SETTING MODE e Press On Off to shut off the power e Hold Tare and press On Off to turn the scale on e The display will show LBK LOLBK and then enter the auto shut off mode e The display will show OFF PWR or XX PWR XX is the number of minutes before the scale would shut off automatically if it has remained stable for the set amount of time 6 2 SETTING OF AUTO SHUT OFF FUNCTION e Press Tare to change the setting of the function e OFFPWR means that the function is disabled 11 Adam Equipment Company 2008
8. age weighing function is off in weighing mode press Func key to overleap the 96 weighing function and move to the next setting directly e Press Unit key to confirm the setting and look through the next setting It enters user s simple cal function when it displays On CAL or OH CAL 6 6 USER CALIBRATION FUNCTION e Press Tare key to switch on or off the function e OF CA the function is off e ON CAL the function is on when the user cal function is off in weighing mode press Func key to overleap this function and move to the next setting e Press Unit key to confirm the setting and enter the next setting It enters unit setting when it shows O1 g or OF g 6 7 SELECTION OF WEIGHING UNITS Each weighing unit can be set to be either on or off If it is on it is available when the user presses the Unit key during normal weighing If it is off the weighing unit is not available during normal use The grams unit is always on e Press Tare key to change the unit from on to off e On the unit is activated e Off the unit is disabled e All the units will be in the following sequence Kg Ib oz Lb Z e Press Unit key to confirm and move to the next setting Turn the scale off and on again to enter the normal weighing mode and save the changes make 13 Adam Equipment Company 2008 7 0 CALIBRATION Calibration is recommended for best accuracy It is suggested that the scale be c
9. alibrated when first installed and any time the scale is moved to a different environment To ensure best accuracy calibrate before use Ensure weights are ready before calibrating the weight should be of a known accuracy for example OIML class M1 or Class 4 of ASTM E617 Do not calibrate the scale if no calibration weight is available 7 1 AUTOMATIC EXTERNAL CALIBRATION In the weighing mode press Func key to access calibration mode The display will show CAL Press Zero key an access code Pin code is required to continue The display will show Pin Press the Func key then Unit key then Tare key and then press Zero key to confirm the pin code The display will show the weighing unit last used to calibrate the scale S Unit kg or S Unit Lb press Unit key to change to Ib s or kg s for the calibration weighing unit value Press Zero key to start the zero calibration The display will show CALO and when the stable symbol is displayed press Zero key to confirm The display will now show the calibration mass expected CAL XXKg or CAL XXLb Press Tare key to change the calibration values if necessary Each model has 3 different kg and lb calibration selection values 14 Adam Equipment Company 2008 Calibration selection values for all model LBK 3 6a LBK 6 12a LBK 12 25a LBK 30 65a 21b 41b 6lb 4lb 8lb 121b 101b 201b 251b 201b 40lb 60lb e Press Zero key
10. em to be weighed on the pan When the reading is stable the net weight will be shown e Ifa container is used put the container on the pan and press Tare key when the reading is stable The display will show 0 00 and the zero symbol and net weight symbol Adam Equipment Company 2008 5 3 POUND OUNCE MODE When using the pounds ounces weighing unit the display will show the results rounded to the nearest ounce Weight Display Readability specification Readability 0 020z max capacity 6Lb LBK6 12a 11Lb15 90z 11 15 9 Readability 0 10z max capacity 12Lb LBK12 25a 24Lb15 90z 24 15 9 Readability 0 10z max capacity 25Lb LBK30 65a 64Lb15 80z 64 15 8 Readability 0 20z max capacity 65Lb 5 4 PARTS COUNTING FUNCTION e n normal weighing mode press Func key to move to parts counting mode e The display will show PC 10pcs press Tare key to go through the preset sample piece values of 101 625 50 or 100 pieces For example if you selected PC 25pcs hand count out 25 pieces and put them on the scale e Press Zero key once the stability indicator comes on to confirm the entered value The display will show the number of pieces placed on the pan e f more items are put on the pan the increased count value will be shown e If acontainer is used place the empty container on the pan before entering parts counting mode then press Tare key to remove the weight of the empty container Then press
11. rgeable battery must be shipped separate from the scale In this case the user must install the battery Remove the battery cover under the scale and put the 6v 4Ah rechargeable battery provided in to the battery compartment Connect the battery to the cable paying attention to the polarity The red connector goes to the positive terminal on the battery the black connector goes to the negative terminal on the battery The power cord or DC adapter provided with the scale is used to charge the battery Make certain the power cord DC adapter matches the voltage of the location you are using the scale in Adam Equipment Company 2008 5 0 WEIGHING 5 1 BEFORE WEIGHING Check the setting of the auto shut off function see section 6 2 If the auto shut off function is on the scale will shut off after a period of time if the scale is not used and it has a stable reading 5 2 WEIGHING e Press On Off to turn on the scale The display will show LBK 10 LBK and show the current voltage XXvol Then it will begin it s self checking test from 0 to 9 When the reading is stable the display will show 0 00 stable symbol zero symbol and the weighing unit used the last time the scale was used e Press Unit to select units Press Unit to select units from g Kg Ib oz Lb z Ys e Check if the reading is 0 00 if not press Zero 0 00 and the zero symbol will be displayed e Putthe it
12. ses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Shielded interconnect cables must be employed with this equipment to insure compliance with the pertinent RF emission limits governing this device Changes or modifications not expressly approved by Adam Equipment could void the user s authority to operate the equipment ay Sealed Lead Acid EN Battery Va Must be recycled PB Properly WEEE COMPLIANCE Any Electrical or Electronic Eguipment EEE component or assembly of parts intended to be incorporated into EEE devices as defined by European Directive 2002 95 EEC must be recycled or disposed using technigues that do not introduce hazardous substances harmful to our health or the environment as listed in Directive 2002 95 EC or amending legislation Battery disposal in Landfill Sites is more regulated since July 2002 by regulation 9 of the Landfill England and Wales Regulations 2002 and Hazardous Waste Regulations 2005 Battery recycling has become topical and the Waste Electrical and Electronic Eguipment WEEE Regulations are set to impose targets for recycling Adam Eguipment Company 2008 17 ADAM EOUIPMENT is an ISO 9001