Home
        User manual DGS-1
         Contents
1.  from 5us to 10 seconds   e The length of f1 and f2 in external modulation mode can be from 7mks and more   e For frequencies above 2 MHz is recommended to use an external filter   e Optional generation of DC voltage in the range of 0 1 4 5 V  Accuracy of the voltage is  0 1V   e Automatic calibration of the output DC voltage when the gain of the amplifier was changed   e LCD display for setting and displaying the device parameters   e Intuitive menu  All settings are saved when the power is turned off   e 4 buttons for menu navigation and settings   e Lighting controlled by the menu   e Power supply from 5V mini USB connector  or  5   9 V from an external power source   e Dimensions 80x45mm  excluding connectors  or 110x45mm given the length of connectors    http   www  bravekit com    Device map    Power supply Connector for    external modulation        4   T y  A    4  m da  7  2  j     E  A s    3  R    eo    DGS 1 At A    SELECT  button    Power supply  5V EXIT PREV NEXT  from mini USB button button button    http   www  bravekit com       Calibration  jumper    Potentiometer for  gain of amplifier    OA DDS  jumper    Power supply     Power supply can be connected in two ways   e Power supply  5V from mini USB connector X3  Just connect mini USB cable from any USB port to DGS 1  and  device now is powered up    e Power supply from external  5   9V power supply unit  which must be connected to black connector X4  This  power input protected against reverse polarity of t
2.  output voltage  which allows for the current gain of the built in amplifier  To view  these limits of the voltage settings  go to  Settings   Uout   Uinfo  menu  In the future   if you set the output voltage  which exceed this limits  the device is not allowed to  set this voltage       For running device in voltage generation mode  you must     Information about version of hardware and software    To check the version of the board  HW  and version of firmware  SW   go to the menu   Info  in the root menu     Go to    Settings     Uout     U setup    menu   Set desired value of voltage  which in range Umin Umax   Press   EXIT    In this case  the selected value is stored in non volatile memory and  will be restored automatically when you turn on the power  If at the moment the       device was in generation state in mode  Voltage   the selected voltage is established immediately at the output of  device   If the selected voltage is outside the range Umin Umax  see menu  Settings   Uout   U Info    you will see message  that U  lt Umin  if set voltage less than the lower limit  or U gt  Umax  when the set voltage is greater than the upper  limit   Then the device automatically returns to the    U setup    menu   Go to    Stopped    menu item and press    SELECT    button  Text of this menu item should be changed to  RUN   thereby  indicating that the device in generating state   Voltage set value can be changed in a state of generation     it is will be instantaneously establ
3.  the device automatically returns to the    f1 duration    menu   Similarly  for the    t2 duration    do same steps       For running DGS 1 in    Auto FSK    mode  you must     Set f1 and f2 frequencies   Set t1 and t2 duration   Set desired form of signal  sinusoidal  square or rectangular  in menu    Form      Select    AutoMod    menu item in menu    Mode      Go to    Stopped    menu item and press    SELECT    button  Text of this menu item should be changed to  RUN   thereby  indicating that the device in generating state   You can change any parameters f1  f2  t1  t2  and  form  during DGS 1 in generation state  Any change will be  immediately applied to the generated signal    http   www  bravekit com    Examples of generated signal in Auto FSK mode     CH1 1 00   500 0us    RIGOL    500 0us    CH1 1 00   500 0us    http   www  bravekit com       Sinusoidal signal in Auto FSK mode  f1 1kHz  t1 3000us   f2 5kHz  t2 1500us    Square signal in Auto FSK mode  f1 1kHz  t1 3000us   f2 5kHz  t2 1500us    Triangular signal in Auto FSK mode  f1 1kHz  t1 3000us   f2 5kHz  t2 1500us    External FSK modulation mode     generating of FSK modulated signal  which controlled  from external input    This mode is designed to generate an FSK modulated signal  the frequency that corresponds to the values of the frequencies  f1 and f2  and the duration of the each frequency corresponding to the states of the external modulation input   MOD    When  the input   MOD   present logic  1  or 
4. Signal generator DGS 1           2          o Aw  b  gt                       Tan a          gt     K      gt   e   gt              gt                 a i A    Ki 8 E      Lee Va     eg A e      e b   gt   VIN    Ae t Se       jo 2     lt     Ki    User manual    Introduction    VEO CIC COIN ME 2  SET 2  Device maD WE 3  Power                     ee EE 4  DS HERE 4  DESCRIPTION OF MENU eiert EE 5  VE ele e E 5  Displays the current Settings of the device                                                    6  C  nirotand UE ONS coc cine coseence asp tented aea aeS ANEO EEEE EPERE EERE ERER ERS 7  Te Ar 7  DESIGN 8  Usual mode  generating signal with f1 frequency without FSK modulation                                                                                                                     8  Auto FSK mode   generating of FSK modulated signal with internal modulation 50       66                                                               9  External FSK modulation mode     generating of FSK modulated signal  which controlled from external Ipput           11    Voltage   mode  generating DC voltage  cox  seesssnuasosseacuswisivinsisn snes duswia  enavasiodsied sweat svinssivaeevatcuseawvavedubteleandadaesande  etcudenweieneavieieuncyee 12  VOUS tee BE 12  Information about version of hardware and software                                                                                                                                                12    http   www  brav
5. cture  To help you navigate through the  menu before each menu item is automatically displayed signs of hierarchy    e The symbol  ai indicates that the menu does not contain a sub menu  and press  the SELECT button will activate this menu  change its state  or to set the numerical  values of this parameter  depending on the menu     e The symbol   gt   indicates that the menu item has a submenu  which you can access  by pressing the SELECT button       If the DGS 1 is in generation state  the  Stopped   RUN  menu parameter is  RUN    then when you change a menu setting   the signal changes instantaneously  in accordance with the specified parameters  If the device is in the  Stopped  state  the  changed parameter will be applied when next starting     Menu options     e Stopped   RUN  start or stop signal generation with the parameters set in the other menu items   e Settings  o f1 main  input value of the main frequency f1     o 2 FSK  input value of the FSK frequency f2  used for FSK modulation    o f1 duration  input value of duration for f1 in auto FSK modulation mod    o f2 duration  input value of duration for f2 in auto FSK modulation    o  Uout      U setup  input value of DC voltage  generated in    Voltage generation    mode     U info  information about min and max DC voltage  which can be generated with set gain of operational amplifier     Calibration  calibration of DC voltage    e Form    O Sinus   generation of signal with sinusoidal form   O Square  generati
6. ed signal  which controlled from external input  If the input logic  1   is present at modulation input or no control signal is present at this input  the output signal is present at a  frequency f1  If the input logic  O  is present at modulation input  the output signal is present at a frequency  f2  o   U x xxV    where x xx     any voltage  for example   U 3 25V     This informs that in the current settings is  selected generate a constant voltage level corresponds displayed on the screen     To exit from the state of display options   and automatic entry in the menu  press In this example showed state of    any button on the instrument board  You stopped generation  After starting will  be generated square signal with f1    will be automatically moved to the  frequency    device menu  Subsequent presses  buttons will navigate through the menu  as usual     In this example  DGS 1 is in generation  state  It is do generate sinusoidal  signal with FSK modulation       http   www  bravekit com    Control and buttons     DGS 1 controlled by using the four buttons  SELECT  selection   NEXT  next   PREV  previous  and EXIT  out   back          SELECT   button used for     e Entry into the current directory menu  if on LCD is showed the   gt   icon before the current menu item   e Select the current menu item as active  if on LCD is showed the         icon before the current menu item   e Changing of the current digit when setting the frequency  duration or value of the output v
7. ekit com    Introduction    The signal generator DGS 1 is designed to generate signals of sine  square and triangular waves with different  frequencies  and to generate DC voltage in the range of 0 1 4 5V In DGS 1 is based on AD9833 DDS  direct digital synthesis  chip   and has a user friendly interface controls and compact size     Features    e Signal generation of sine  triangle or square wave in the frequency range 0 12 5 MHz  according to the  documentation for DDS  with a step of 1 Hz frequency   e Stability   100ppm   e   Built in amplifier   e The ability to select the source   directly or through an amplifier DDS   e peak to peak voltage of signal which generated from the output of DDS is 0 038 0 65V   e Peak to peak voltage of sinusoidal or triangular signal from the amplifier output is 0 1V 4  6V  The upper peak  of the generated signal can be reduced by adjusting the gain of the operational amplifier  by adjusting  potentiometer    e voltage amplitude of the square wave signal from output of amplifier is 0 1 to 4  6B  and does not depend  from the gain of the amplifier    e Generation of FSK signals  FSK binary modulation  without breaking phase  Modulation can be performed by  the internal modulation source  automatic modulation   duration of f1 and f2 is determined by parameters  set by the user from the menu   and by external logic signal  external modulation  with the voltage level no  more than 5V   e The length of f1 and f2 in the automatic modulation can be
8. em should  be changed to  RUN   thereby indicating that the device in generating state       20 00us    Sinusoidal signal in usual mode  f1 10kHz Square signal in usual mode  f1 10kHz Triangular signal in usual mode  f1 10kHz       http   www  bravekit com    Auto FSK mode   generating of FSK modulated signal with internal modulation source    This mode is for generating FSK modulated signal with frequencies f1 and f2  Duration of each signal selected in    f1 duration     and    f1 duration    menu parameters  The transition from one frequency to another occurs without breaking phase     For set duration of signal  you must     Go to    Settings   f1 duration    menu item   using the   NEXT   and   PREV   buttons  move the cursor to the desired digit  current  cursor position is shown underlined   then pressing the   SELECT   select the desired  numerical value of the discharge  after each pressing the   SELECT   this digit will  increase by 1  after the number 9 he was again reset to  0    Once you have set the desired frequency  press the button   EXIT    In this case  the  duration t1 is stored in non volatile memory  and will be automatically restored  when you turn on the power  If the device was in generation state in mode     AutoMod     the selected duration will be immediately applied to generated signal  The duration value should not be less than 5us  Otherwise  when you press the  button   EXIT   the message about exceeding the allowable limit will be shown  then 
9. f1 main      using the   NEXT   and   PREV   buttons  move the cursor to the desired digit  current  cursor position is shown underlined   then pressing the   SELECT   select the desired  numerical value of the discharge  after each pressing the   SELECT   this digit will  increase by 1  after the number 9 he was again reset to 0        Once you have set the desired frequency  press the button   EXIT    In this case  the selection of frequency f1 is stored  in non volatile memory  and will be automatically restored when you turn on the power  If the device was in  generation state in the modes  Normal       AutoMod  or  ExtMod   selected frequency f1 will be immediately applied  to generated signal   The selected frequency shall not exceed value 12500000 Hz  Otherwise  when you press the button   EXIT   the  message about exceeding the allowable frequencies will be showed  then the device automatically returns to the input  frequency menu    For start generating signal in usual mode you must     Set desired value of frequency f1   In menu  Form  to select the desired waveform  sine  square  or triangle   To select the  desired form you must go to menu item press the button   SELECT    In this case  near  the selected menu item appears     sign  see the section  Backlight    In    Mode    menu go to    Usual    menu item and press   SELECT   button  Near the  selected menu item appears     sign   Go to    Stopped    menu item and press    SELECT    button  Text of this menu it
10. he applied voltage     X4    PWR     VIN 3 See   Sek   IN OUT   AM i   GND OUT   0 1 REG1117 5 0    GND_D    IN OUT    GND OUT    REG1117 3 3       Power supply schematic    Signal output    The device DGS 1 has a built in amplifier to operate over the full frequency range of the generated signal  However  a  situation may arise when the parameters of the amplifier will not be sufficient  In this case  use an external amplifier and a  signal to take directly from the output of DDS  The device DGS 1 provides such an opportunity with a jumper OA   DDS  Position   DDS  connects the output signal from the DDS directly to the output connector  The voltage peak to peak signal is generated  0 038 0 65V  Attention  Connecting directly to the DDS output low impedance load   lt 1kOhm  can lead to failure of the  device     Selecting built in amplifier with   OA   jumper DDS output connecting directly to output of  position DGS 1 with   DDS   jumper position       At the    OA    position signal arrives to the output connector through the operational amplifier  Gain of operational  amplifier is adjustable by the potentiometer  In this case  the peak voltage of generated sinusoidal or triangular signal from the  amplifier output can be up to 4 6 V  Voltage peak to peak square wave is 0 1 to 4 6V  and does not depend on the gain of the  operational amplifier     http   www  bravekit com    Description of MENU    The menu displayed on the LCD display  and has an intuitive hierarchical stru
11. ished at the device  output    http   www  bravekit com       12    
12. oltage      NEXT   button used for   e Moving to next menu item      PREV   button used for   e Moving to previous menu item      EXIT   button used for   e Exit from current menu item to parent menu item  e Exit from menu of set digits for f1  f2  t1  t2  or voltage value  In this case  when you press the EXIT button   this parameter will be saved in non volatile memory device  and this parameter will be applied to the  generated signal  application occurs  on the fly  when the device is in a state of generation     Backlight     LCD display of DGS 1 have backlight  For enabling backlight you must   e Go to menu item   Light     e press   SELECT   button  e Now backlight is used  Near    Light     menu item must occur         symbol   which indicate that this parameter is active  e For disabling backlight press   SELECT   button on   Light    menu item  again       The status  Backlight  is stored in non volatile memory  and will be automatically applied when you turn on the power     http   www  bravekit com    Description of modes     DGS 1 can operate in several modes  each of which can be selected in the menu  Mode     Usual mode  generating signal with f1 frequency without FSK modulation      This mode is for generating a signal frequency f1  Set the frequency in the range of 0 12 5MHz with 1 Hz step  The set value is  stored in non volatile memory and will be restored automatically when you turn on the power     For set frequency value  you must     Go to    Settings  
13. on of signal with square form   o Triang   generation of signal with triangular form     o Usual  generation of signal with f1 frequency without FSK modulation   o AutoMd  FSK signal generation with the parameters set by the user   o ExtMod  generating FSK signal controlled by an external logic signal or relay   o  Voltg   generation of DC voltage in range 0 1 4 5V   e   Light  backlight on off     e   Info  information about version of hardware and software     http   www  bravekit com    Displays the current settings of the device     If the user does not press any of the buttons for more than 10 seconds  the device switches to display its current state  except  for the situation where an active menu for input digits of frequency f1 and f2  f1 duration or f2  or enter the value of the DC  voltage   In this case  the screen displays     e Atthe left side of upper row information about status of signal generating  o   RUN     Signal is generated   o   Stop    generation stopped   e At heleft side of upper row information about form of signal  o   SIN    sinusoidal signal   o   N_A    square signal   o   AAA    triangular signal   o   U      DC voltage generated   e At the bottom row information about mode   o   Gener  f1     generation of signal with f1 frequency without FSK modulation  o   AutoMod     generation of FSK modulated signal with f1 and f2 frequencies  duration for 11 and f2 set in    f1  duration    and    f2 duration      o   ExtMod     generation of FSK modulat
14. signal not present DGS 1 generate f1 frequency  When the input   MOD   present logical   O  or the input is connected directly to ground unit  second contact of   MOD   connector   DGS 1 generate signal with a  frequency f2  The transition from one frequency to another occurs without breaking phase  Control on   MOD   input can be  performed by any control device that generates pulses  and from the relay  The voltage level of the logic  1  at the input    MOD   should be 2 5 5 1V  The voltage level of logic  O  at the input   MOD   should be 0 0 2V    The delay between the edge of the control signal at the   MOD   input and changing the frequency at the output is 7us    For running device in    External modulation    mode  you must     e Set f1 and f2 frequencies   e Select signal form in menu    Form     Sinusoidal  Square or Triangular    e Inmenu    Mode    select    ExtWMod    menu item   e Goto    Stopped    menu item and press    SELECT    button  Text of this menu item should be changed to  RUN   thereby  indicating that the device in generating state   e  lt Any from parameters f1  f2 and form can be changed during generation state of device  Any change will be  immediately applied to the generated signal   e Frequency of generated signal   e frequency of the generated signal is changed from f1 to f2  and vice versa  depending on the input state   MOD                       HI  1 DOUM d 2 00   1 000us    7    Sinusoidal signal in mode    External modulation    Delay be
15. tween the edge of the control signal at the   MOD   input  f1 1kHz  f2 10kHz  and changing the frequency at the output 7us   Sinusoidal signal in mode    External modulation       f1 1kHz  f2 100kHz   Graph N21  yellow   this is generated signal   Graph N22  blue  this is signal at    MOD    input    http   www  bravekit com       11      Voltage   mode  generating DC voltage     This mode is used to generate a DC voltage in the range of 0 1 4 5 V  Generation function is implemented on the basis of the  DAC module of DDS chip  so the accuracy of output voltage is not better than   0 1 V  Function of voltage generation only  works with built in amplifier  jumper   OA   DDS   must be set to   OA       Voltage calibration    The accuracy of the generated voltage depends largely on the stability of the gain built in amplifier  If the gain is changed  after  adjustment potentiometer   to recover the accuracy of output voltage should be recalibrated    For calibration  you must     Install   Calbr    jumper  it is located under signal output connector    Set    OA    jumper   Disconnect cable from signal output   Go to    Settings     Uout     Calibr     menu item and press   SELECT    This will start the  automatic calibration of output voltage    After the end of the calibration process you will see message  Calibration ended    and the device will automatically switch to the menu  Uout      During the process of calibration automatically calculated upper and lower limits of  the
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
RB397(CE)  Aprilaire 3410 User's Manual  XC-3 GMega LX取扱説明書  Mosaic Theory MTIA20-003WHT  Bedienungsanleitung User manual FKL 50  Webspike 1.0 User`s Manual  SPI-6941-LV  Hps 446 patrol line  Digital Inverter Generator G4000X Operating Instructions      Copyright © All rights reserved. 
   Failed to retrieve file