Home
Bedienungsanleitung User manual FKL 50
Contents
1. EL O OkO Figure 1 Figure 2 Figure 3 LASER SPOT CENTERING Switch on the laser and press button 4 and 5 simultaneously Now laser dot will center auto matically While centering procedure the display will show gt lt When centering procedure is completed display will show With buttons 4 right and 5 left laser dot can be shifted rightwards or leftwards Single pressing slow shifting in the direction selected Continuous pressing quick shifting in the di rection selected When shifting the laser dot below symbols will be displayed Figure 1 the laser dot is in the most left position Figure 2 the laser dot is in left position Figure 3 the laser dot is centered Figure 4 the laser dot is in right positon Figure 5 the laser dot is in the most right position The laser dot can also be shifted with the re mote control O O Figure 4 Figure 5 12 ANZEIGE LASERDREHPUNKT Mit Taste 3 Displaybeleuchtung einschalten gleichzeitig wird damit auch die LED des Laser startpunkts aktiviert Ab diesem Punkt beginnt die Neigung des Laserstrahls was Einflu auf die Einstellung der Neigung hat Erneut Taste 3 dr cken um die Funktion wieder auszuschalten Diese Funktion kann auch ber die Fernbedie nung aktiviert werden INDICATION OF ROTATION CENTRE Press button 3 to illuminate display and to ac tivate LED of laser start point From this point on grade of the las
2. Bedienungsanleitung User manual Kanalbaulaser Pipe Laser FKL 50 LIEFERUMFANG Kanalbaulaser FKL 50 Fernbedienung NiMH Akku Ladeger t Batteriefach f r Alkalinebatte rien Fu f r 3 Beinaufstellung F e DN 150 200 300 400 500 Zieltafel Kunststoffkoffer Bedienungsanleitung KIT CONSISTS OF Pipe Laser FKL 50 remote control NiMH batte ries charger battery case for alkaline batteries adapter for 3 leg set up leg sets DN 150 200 300 400 500 target container user manual A INT dapter f r Dreibeinaufstellung Adapter for MERKMALE UND FUNKTIONEN Robustes Metallgeh use Einfache Handhabung Automatische Horizontierung Richtungszentrierung LED Anzeige des Laserausgangspunktes am Geh use Beleuchtetes Display Wiederaufladbarer NIMH Akku Infrarot Fernbedienung TECHNISCHE DATEN Laserklasse Laser sichtbar rot Strahldurchmesser Reichweite Neigungsbereich Selbstnivellierbereich Ablesegenauigkeit Horizontalgenauigkeit Neigungsgenauigkeit Richtungseinstellbereich Seitlicher Richtungs einstellbereich Seitliche Richtungs zentrierung Betriebszeit Temperaturbereich Stromversorgung Reichweite Fernbedienung von vorn hinten Schutzklasse Abmessungen Gewicht nur Laser Gewicht Set 3R lt 2mW 635nm 12 mm bis 200 m 20 bis 40 59 0 001 5 mm 100 m 15 mm m ke Fe Fe l O 4 8 o o a w 24h NiMH 20 C bis
3. 50 C 4xD 8000 mAh NiMH alternativ 4xD Alkaline 6O0Om 10m IP 68 132 mm L 380 mm 5 kg 11 kg FUNCTIONS AND FEATURES Robust aluminium housing Easy intuitive operation Fully automatic self levelling Automatic beam centring Laser start point indication Clear easy to read illuminated LCD display Integrated rechargeable batteries Remote control TECHNICAL DATA Laser class Laser diode power Beam diametre Working range Grade range Self levelling range Minimum display reading Horizontal accuracy Grade accuracy Left right scanning Line range Line center Operating time Temperature range Power supply Remote control range front back Dust water protection Size Weight laser only Weight set 3R lt 2mW 635nm 12 mm bis 200 m 20 bis 40 59 0 001 5 mm 100 m 15 mm m W a a O 4 8 0 0 yes 24h NiMH 20 C to 50 C 4xD 8000 mAh NiMH alternatively 4xD Alkaline 60m 10m IP 68 132 mm L 380 mm 5 kg 11 kg BEDIENELEMENTE 1 LC Display 2 Bedienfeld 3 Griff 4 Ladebuchse 5 Batteriefach 6 F e 7 1 4 Adapter 8 Startmarke Laserstrahl 9 Laseraustrittsfenster 10 Vorderes Empfangsfenster Fernbedienung 11 Startmarke Laserstrahl 12 Hinteres Empfangsfenster Fernbedienung 13 Aufnahmegewinde f r Adapter Dreibein aufstellung 13 FEATURES 1 2 3 4 5 6 7 8 9 10 11 12 13 LC di
4. Displayanzeige blinkt nicht Das Ger t steht links hoch ist aber noch im Bereich der Toleranz ec Displayanzeige Das Ger t ist perfekt nivelliert genauste Leistung des Lasers Displayanzeige blinkt nicht Das Ger t steht rechts hoch ist aber noch im Bereich der Toleranz Displayanzeige BLINKT Das Ger t ist rechts au erhalb MES der Toleranz Ausrichtung korrigieren Display indication 1 handle side of the instrument must be inclined downwards Querneigung The laser is equipped with a digital vial that shows alignment of the instrument Laser is set up correctly if the vial is centered CI Display FLASHES The laser is out of tolerance on the left side correct set up Display does not flash The laser is set up high on the left side but still within tolerance Display l The laser is perfectly levelled most accuracte performance Display does not flash The laser is set up high on the right side but still within tolerance CI Display FLASHES The laser is out of tolerance on the rigtht side correct set up 10 NEIGUNGSEINSTELLUNG Neigungseinstellbereich 20 40 Ger t einschalten und mit Taste SET die Nei gungseinstellung anw hlen Displayanzeige 00 000 Mit der Taste SET k nnen alle Stellen nachein ander angesteuert werden Mit den Tasten 2 auf ab werden Neigungs werte f r jede Stelle eingestellt Nied
5. Garantieanspruch besteht nur bei bestim mungsgem er Verwendung Mechanischer Verschlei und u erliche Zerst rung durch Gewaltanwendung und Sturz unterliegen nicht der Garantie Der Garantieanspruch erlischt wenn das Geh use ge ffnet wurde Der Her steller beh lt sich vor im Garantiefall die schadhaften Teile instand zusetzen bzw das Ger t gegen ein gleiches oder hnliches mit gleichenwertigen technischen Daten auszu tauschen Ebenso gilt das Auslaufen der Bat terie nicht als Garantiefall ELECTROMAGNETIC ACCEPTABILITY EMC It cannot be completely excluded that this instrument will disturb other instruments e g navigation systems will be disturbed by other instruments e g intensive electromagnetic radiation nearby industrial facilities or radio transmitters CE CONFORMITY Instrument has CE mark in accordance with EN 61010 1 2001 corr 1 2 EN 60825 1 2007 WARRANTY This product is warranted by the manufac turer to the original purchaser to be free from defects in material and workmanship under normal use for a period of two 2 years from the date of purchase During the warranty period and upon proof of purchase the product will be repaired or replaced with the same or similar model at manufacturers option without charge for either parts or labour In case of a defect please contact the dealer where you originally purchased this product The warranty will not apply to this product if i
6. Laser P lt 5 mW 522 542 nm Roter Laser P lt 5mW 635 670 nm 17 LASER CLASSIFICATION The instrument is a laser class 3R laser pro duct according to DIN IEC 60825 1 2007 The measuring tool should be operated only by persons who are familiar with the handling of laser devices According to EN 60825 1 this includes among other things the knowledge about the biological effects of the laser to the eyes and the skin as well as the correct usage of laser protection devices in order to avoid dangers Laser class 3R warning labels on the laser instrument LASER RADIATION AVOID DIRECT EYE EXPOSURE TO THE LASER BEAM LASER CLASS 3R as per DIN EN 60825 1 2007 Green laser P lt 5 mW 522 542 nm Red laser P lt 5 mW 635 670 nm ELEKTROMAGNETISCHE VERTR GLICHKEIT Es kann nicht generell ausgeschlossen wer den dass das Ger t andere Ger te st rt z B Navigationseinrichtungen durch andere Ger te gest rt wird z B elek tromagnetische Strahlung bei erh hter Feld st rke z B in der unmittelbaren N he von Industrieanlagen oder Rundfunksendern CE KONFORMIT T Das Ger t hat das CE Zeichen gem den Normen EN 61010 1 2001 Korr 1 2 EN 60825 1 2007 GARANTIE Die Garantiezeit betr gt zwei 2 Jahre begin nend mit dem Verkaufsdatum Die Garantie erstreckt sich nur auf M ngel wie Material oder Herstellungsfehler sowie die Nichterf llung zugesicherter Eigenschaf ten Ein
7. STATUS INDICATION Nach dem Einschalten wird der Batteriezustand After switching on the unit the instrument will des Ger tes berpr ft und wie folgt angezeigt check and show battery status as follows B E e 1 Akku voll geladen 1 Battery fully loaded 2 Niedrige Akkuleistung Batterie sollte vor 2 Low battery power it is advised to charge Gebrauch geladen werden battery before working 3 Akku leer Aufladen unbedingt erforderlich 3 No battery power battery must be charged 4 x D Alkaline Batterien 4 x D alkaline batteries Der Laser kann alternativ mit Alkaline Batterien Instrument can be used with alkaline batteries betrieben werden alternatively Verschluss des Batteriefachs aufschrauben Unscrew lock of battery door and remove und Akkupack herausnehmen Alkaline Batte NiMH battery case Put in alkaline batteries rien in das daf r vorgesehene Fach einlegen into alkaline battery case take care to polarity Polarit t beachten das Fach in das Ger t put case into the laser and lock again einsetzen und Ger t wieder verschlie en TASTATUR 1 An Aus Schalter 2 Tasten Neigungseinstellung 3 Displaybeleuchtung Anzeige Laserstartpunkt 4 Laserpunkt nach links 5 Laserpunkt nach rechts 6 Empfangsfenster Fernbedienung 7 LCD Anzeige KEYPAD 1 On Off button 2 Grade setting buttons 3 Display illumination indication laser starting point 4 Laser dot direction move left 5 Laser
8. dot direction move right 6 Remote control receiving window 7 LCD display DISPLAYANZEIGE DISPLAY INDICATION Vorzeichenanzeige Neigungseinstellung Prozentanzeige indication Grade value Percentage 00 000 x Digitallibelle Batteriezustandsanzeige Richtungsanzeige Laser Digital bubble Battery status indication Laser direction indication GER T AUFSTELLEN Vor dem Aufbau die f r den Rohrdurchmesser geeigneten F e ausw hlen Das Ger t muss so ber dem Ausgangspunkt aufgestellt werden dass die Libelle im Display Mittelposition anzeigt und kein Richtungspfeil mehr zu sehen ist Nun die gew nschte Nei gung einstellen und den Laserstrahl auf den Zielpunkt ausrichten Das Rohrende immer nach der Zieltafel ausrichten BEDIENUNG Zum Einschalten Taste 1 f r ca 1 Sek ge dr ckt halten Der FKL 50 initialisiert und be ginnt zu arbeiten Wenn Taste 1 nicht lang ge nug gedr ckt wird initialisiert der FKL 50 nicht korrekt Zum Ausschalten erneut Taste 1 dr cken Der FKL 50 kann auch ber die Fern bedienung ausgeschaltet werden AUSRICHTUNG DES GER TES Neigung vorn hinten in Laserrichtung Wenn das Ger t au erhalb des Selbstnivellier bereiches aufgestellt oder die Neigung au er halb des Selbstnivellierbereiches eingestellt wurde beginnen der Laserpunkt und die LED zu blinken Ger t dann auf einer ebeneren Fl che aufstellen oder eingestellte Neigung wie folgt korrigieren Displayanz
9. eige cr 1 Ger t muss mit der Griffseite weiter nach oben vorgeneigt werden SET UP LASER Before setting up the laser select appropriate legs for the tube diametre When the vial displayed in the LCD is centered and the direction arrows disappear instrument is set up correctly Now adjust the inclina tion and align the laser beam to the target Continue aligning each pipe end to the target OPERATION Press power key 1 for approx 1 sec to switch on the FKL 50 The laser will complete initiali zation and begin to work If the power key has not been pressed long enough the FKL 50 will not initialize correctly Press key 1 again to switch FKL 50 off It can also be switched off with the remote control ALIGNMENT OF THE LASER Inclination front back in laser direction If instrument was set up beyond self levelling range or if grade setting is beyond same laser dot and LED will flash Then set up instrument on a more even surface or correct grade set as follows Display indication te x handle side of the instrument must be inclined upwards Displayanzeige 1 _ Ger t muss mit der Griffseite weiter nach unten vorgeneigt werden Querneigung Das Ger t hat eine digitale Libelle die die Ausrichtung des Ger tes anzeigt Ger t immer so aufstellen dass die Libelle im Zen trum ist Displayanzeige BLINKT Das Ger t ist links au erhalb der Toleranz Ausrichtung korrigieren
10. er beam will start which influences the grade setting Press button 3 again to quit This function can also be activa ted with the remote control Laserstartpunkt Start laser point L2 Neigung H L1 L2 Grade H L1 L2 FERNBEDIENUNG Im Lieferumfang des FKL 50 ist eine Fernbe dienung enthalten Die Tastenfunktionen sind die gleichen wie auf dem Ger t Ausnahme Taste AN AUS Wenn das Ger t eingeschaltet ist wird es mit der AN AUS Taste auf Stand by geschaltet Die eingestellten Werte werden gespeichert das Ger t h rt auf zu arbeiten Der Laserstrahl ist ausgeschaltet der Laserpunkt blinkt schnell AN AUS Taste erneut dr cken um das Ger t wieder in Betrieb zu setzen Wenn das Ger t l nger als 30 Min auf Stand by geschaltet ist stellt es sich automatisch aus Reichweite der Fernbedienung vorn 60 m Laseraustrittsfenster Reichweite der Fernbedienung hinten 10 m Ende Griff 13 REMOTE CONTROL FKL 50 pipe laser is supplied with remote con trol The keypad functions of the remote are the same as of the laser Exception button ON OFF If the laser is switched on it will be turned to standby mode by pressing ON OFF button The values set will be stored the laser stops working the laser beam is turned off and the laser beam flashes quickly Press button ON OFF again to re start working If the laser is in standby mode for more than 30 min it will automatically switch off Remote c
11. ly Do not attempt to dismantle intrument Repairs should only be carried out by geo FENNEL authorized workshops Please contact your local dealer Do not remove warning labels or safety instru ctions Keep instrument away from children Do not use in agressive or explosive environ ment SPECIFIC REASONS FOR ERRONEOUS MEASURING RESULTS Measurements through glass or plastic win dows Dirty laser emitting windows After instrument has been dropped or hit Please check accuracy Large fluctuation of temperature If instru ment will be used in cold areas after it has been stored in warm areas or the other way round please wait some minutes before car rying out measurements 16 LASERKLASSIFIZIERUNG Das Ger t entspricht der Lasersicherheitsklas se 3R gem der Norm DIN EN 60825 1 2007 Ger te der Laserklasse 3R sollten nur durch Personen bedient werden die mit dem Einsatz von Lasern vertraut sind Anwendungsbereiche sollten mit Laserwarn schildern gekennzeichnet werden Der Laserstrahlgang sollte nicht ber unbe wachte Bereiche hinausgehen Vorsichtsma nahmen sind zu treffen damit der Laserstrahl nicht ungewollt auf Fl chen f llt die wie ein Spiegel reflektieren und dass Personen nicht direkt in den Strahl blicken Laserwarnschilder der Klasse 3R sind gut sichtbar am Ger t angebracht LASERSTRAHLUNG DIREKTE BESTRAHLUNG DER AUGEN VERMEIDEN LASERKLASSE 3R nach DIN EN 60825 1 2007 Gr ner
12. m When the laser levels the grade symbol is flashing When self levelling procedure has been completed flashing stops Pressing both arrow keys 2 will re set the grade value to zero again ADVICE to accelerate change of grade setting Confirm change of grade setting i e from 4 to 15 with button ENT and switch off laser Then switch on laser again and now laser aligns faster to new grade value in the coarse mode ZENTRIERUNG DES LASERPUNKTES Ger t einschalten und die Tasten 4 und 5 gleichzeitig f r eine Sek gedr ckt halten Nun zentriert sich der Laserpunkt automatisch W hrend des Zentriervorgangs zeigt das Dis play an gt lt Nach dem Zentriervorgang zeigt das Display an Mit den Tasten 4 links und 5 rechts kann der Laserpunkt horizontal nach rechts oder links verschoben werden Punktuelles Dr cken langsame Bewegung des Laserpunktes in die gew nschte Richtung Dauerhaftes Dr cken schnelle Bewegung des Laserpunktes in die gew nschte Richtung Wenn der Laserpunkt bewegt wird zeigt das Display diese Bewegung siehe unten an Figure 1 der Laserpunkt ist in der u ersten linken Position Figure 2 der Laserpunkt ist auf der linken Seite Figure 3 der Laserpunkt ist zentriert Figure 4 der Laserpunkt ist auf der rechten Seite Figure 5 der Laserpunkt ist in der u ersten rechten Position Der Laserpunkt kann auch ber die Fernbedie nung eingestellt werden
13. nd B and wait until self levelling procedure is completed Measure height from the centre of the laser line to points A and B and mark the A2 and B2 If A2 A1 B2 B1 lt 3 mm accuracy is okay If A2 A1 gt B2 B1 laser line is too high and must be adjusted If A2 A1 lt B2 B1 laser line is too low and must be adjusted 14 UMGANG UND PFLEGE e Messinstrumente generell sorgsam behandeln e Nach Benutzung mit weichem Tuch reinigen ggfs Tuch etwas in Wasser tr nken Wenn das Ger t feucht war sorgsam trocknen e Erst in den Koffer oder die Tasche packen wenn es absolut trocken ist Bitte darauf ach ten dass auch der Koffer innen immer trocken ist bevor das Ger t hineingepackt wird Transport nur in Originalbeh lter oder tasche SICHERHEITSHINWEISE BESTIMMUNGSGEM SSE VERWENDUNG Das Ger t sendet einen sichtbaren Laserstrahl aus um z B folgende Messaufgaben durchzu f hren Ermittlung von H hen Angabe von rechten Winkeln und Neigungen 15 CARE AND CLEANING e Please handle measuring instruments with care Clean with soft cloth moistened with water or pure alcool if necessary e Ensure the instrument and carrying case are both clean and completely dry before returning for storage or transportation Transport in original container case only SAFETY INSTRUCTIONS INTENDED USE OF INSTRUMENT The instrument emits a visible laser beam in order to car
14. ndung mit Produkten anderer Hersteller verursacht wurden 19 EXCEPTIONS FROM RESPONSIBILITY The user of this product is expected to follow the instructions given in operators manual Although all instruments left our warehouse in perfect condition and adjustment the user is expected to carry out periodic checks of the product s accuracy and general perfor mance The manufacturer or its representatives assumes no responsibility of results of a faul ty or intentional usage or misuse including any direct indirect consequential damage and loss of profits The manufacturer or its representatives assumes no responsibility for consequential damage and loss of profits by any disaster earthquake storm flood etc fire accident or an act of a third party and or a usage in other than usual conditions The manufacturer or its representatives assumes no responsibility for any damage and loss of profits due to a change of data loss of data and interruption of business etc caused by using the product or an unusable product The manufacturer or its representatives assumes no responsibility for any damage and loss of profits caused by usage other than explained in the users manual The manufacturer or its representatives assumes no responsibility for damage caused by wrong movement or action due to connec ting with other products 16 Technische nderungen vorbehalten 4 All instruments subject to
15. ontrol range front 60 m laser emitting window Remote control range back 10 m end of handle PR FUNG DER GENAUIGKEIT L 30m PR FUNG DER GENAUIGKEIT Zwei Punkte A und B markieren die ca 30 m voneinander entfernt sind Laser hinter Punkt A aufstellen einschalten und 10 Min aufw rmen lassen Neigung auf 00 000 einstellen Laserlinie durch Punkte A und B laufen lassen und dann das Ger t nivellieren lassen H he von der Mitte der Laserlinie zu den Punk ten A und B genau messen und als A1 und B1 markieren Ger t hinter Punkt B aufstellen und Laserlinie durch die Punkte A und B laufen lassen Ger t nivellieren lassen H he von der Mitte der Laserlinie zu den Punk ten A und B genau messen und mit A2 und B2 markieren Wenn A2 A1 B2 B1 lt 3 mm ist die Genauigkeit in Ordnung Wenn A2 A1 gt B2 B1 ist die Laserlinie zu hoch und muss justiert werden Wenn A2 A1 lt B2 B1 ist die Laserlinie zu niedrig und muss justiert werden ACCURACY CHECK ACCURACY CHECK Mark two points A and B which are about 30 m apart Set up laser behind point A turn it on and let it warm up for about 10 min Set grade to 00 000 Let the laser line go through points A and B and wait until self levelling procedure is completed Measure height from the centre of the laser line to points A and B and mark them A1 and B1 Set up laser behind point B let the laser beam go through points A a
16. rigste Ziffer O H chste Ziffer 9 Wenn der Cursor auf dem Vorzeichen steht wird mit den Tasten 2 das Vorzeichen ge ndert Punktuelles Dr cken langsames Verstellen der Neigungswerte Dauerhaftes Dr cken schnelles Verstellen der Neigungswerte Wenn die gew nschten Neigungswerte einge stellt sind dies mit der Taste ENT best tigen Wenn der Laser sich nivelliert blinkt das Neig gungssymbol Wenn die Selbstnivellierung ab geschlossen ist h rt das Blinken auf Gleichzeitiges Gedr ckthalten beider Tasten 2 setzt den Neigungswert wieder auf O TIP nderung der Neigungseinstellung be schleunigen Ge nderte Neigungseinstellung z B von 4 auf 15 mit ENT best tigen und Laser aus schalten Dann wieder einschalten und Laser spielt im Grobmodus den Laserstrahl schneller auf den neuen Neigungswert ein 11 GRADE SETTING Grade setting range 20 40 Switch on the FKL 50 and press SET button to select grade setting Display indication O00 000 Select all digits for grade setting with button SHIP With buttons 2 up down the grade values will be set Lowest digit O Maximum digit 9 When the cursor is on the sign you can change same from to with buttons 2 Slow pressing slow setting of the grade values Continuous pressing quick setting of the grade values When the grade values required have been set press button ENT to confir
17. ry out the following measuring tasks Setting up and control heights indication of direction and slopes WARN UND SICHERHEITSHINWEISE e Bitte richten Sie sich nach den Anweisungen der Bedienungsanleitung e Anleitung vor Benutzung des Ger tes lesen Blicken Sie niemals in den Laserstrahl auch nicht mit optischen Instrumenten Es besteht die Gefahr von Augensch den Laserstrahl nicht auf Personen richten e Die Laserebene soll sich ber der Augenh he von Personen befinden e Niemals das Geh use ffnen Reparaturen nur vom autorisierten Fachh ndler durchf hren lassen Keine Warn oder Sicherheitshinweise entfernen Laserger t nicht in Kinderh nde gelangen lassen Ger t nicht in explosionsgef hrdeter Umgebung betreiben UMST NDE DIE DAS MESSERGEBNIS VERF LSCHEN K NNEN e Messungen durch Glas oder Plastikscheiben e verschmutzte Laseraustrittsfenster e Sturz oder starker Sto Bitte Genauigkeit berpr fen e Gro e Temperaturver nderungen Wenn das Ger t aus warmer Umgebung in eine kalte oder umgekehrt gebracht wird vor Benutzung einige Minuten warten SAFTEY INSTRUCTIONS Carefully read the User Manual before use Do not stare into the beam Laser beams can lead to eye injury Directy looking into can cause damage to your eyes Do not aim laser beam directly at persons or animals The laser plane should be set up above eye level Use instrument for its intended tasks on
18. splay Keypad Handle Charging plug Battery compartment Legs 1 4 adapter Start mark of laser dot Laser emitting window Front remote receiving window Starting point of laser dot Back remote receiving window Thread for set up with 3 legs STROMVERSORGUNG Der Laser kann mit NiMH Akku und alternativ mit handels blichen Alkalinebatterien betrieben werden NiIMH Akku Der Laser ist mit einem wiederaufladbaren NiIMH Akkupack ausgestattet Ladeger t mit Netz und Ladebuchse 4 am Ger t verbinden Der Ladezustand wird an der kleinen Lampe am Ladeger t angezeigt Rotes Licht zeigt an dass der Akku geladen wird Gr nes Licht zeigt an dass der Akku voll ge laden ist Der Akkupack kann auch au erhalb des Ger tes geladen werden Einsetzen des Akkufachs Installation of battery pack Akku im Ger t laden Charging battery inside the instrument BATTERY AND CHARGER Both the standard NiMH battery or alkaline bat teries can be used NiMH battery pack FKL 50 comes with NiMH rechargeable battery pack Connect the charger with socket 4 Red light at the charger indicates that batte ries are being charged Green light at charger indicates that batte ries are fully charged The NiMH battery pack can be charged outside of the laser Ladezustandsanzeige Charging LED Akku au erhalb des Ger tes laden Charging battery outside of the instrument BATTERIEZUSTANDSANZEIGE BATTERIE
19. t has been misused abused or altered Without limiting the foregoing leakage of the battery bending or dropping the unit are presumed to be defects resulting from misuse or abuse 18 HAFTUNGSAUSSCHLUSS Der Benutzer dieses Produktes ist angehalten sich exakt an die Anweisungen der Bedie nungsanleitung zu halten Alle Ger te sind vor der Auslieferung genauestens berpr ft wor den Der Anwender sollte sich trotzdem vor jeder Anwendung von der Genauigkeit des Ger tes berzeugen Der Hersteller und sein Vertreter haften nicht f r fehlerhafte oder absichtlich falsche Ver wendung sowie daraus eventuell resultieren de Folgesch den und entgangenen Gewinn Der Hersteller und sein Vertreter haften nicht f r Folgesch den und entgangenen Gewinn durch Naturkatastrophen wie z B Erdbeben Sturm Flut usw sowie Feuer Unfall Ein griffe durch Dritte oder einer Verwendung au erhalb der blichen Einsatzbereiche Der Hersteller und sein Vertreter haften nicht f r Sch den und entgangenen Gewinn durch ge nderte oder verlorene Daten Unterbre chung des Gesch ftsbetriebes usw die durch das Produkt oder die nicht m gliche Verwen dung des Produktes verursacht wurden Der Hersteller und sein Vertreter haften nicht f r Sch den und entgangenen Gewinn resul tierend aus einer nicht anleitungsgem en Bedienung Der Hersteller und sein Vertreter haften nicht f r Sch den die durch unsachgem e Ver wendung oder in Verbi
20. technical changes 02 2011