Home
Leica Tracker Pilot - New River Kinematics
Contents
1. cceeseeeeees 104 DIE fect tee bestia tnd teat thet Avie hte teat Shae dates 22 DELETE mior 36 Mal PASE inae asec SEa A E AEA a 22 Detail Report c ccee 109 116 123 Reflectors entgegen Seen ec 27 DEE 99 StdtUs Bal eebe 24 EMD Ee E 133 Tracker CONOIS srren 23 Je de sanar eee ene ee eno nee 135 Network Inclination Sensor cccceeseeeeeeeeeeeeeeeees 104 Application Computer sesser 56 Modules neisur enian ar 97 DCP se lessee lade tlieremeael eae 59 62 PDF REDON eene 111 118 125 Kelte P2P E 58 62 Prerequisites cccccccseeeesssseeeeeeeeeeeeeees 96 e ee ele 1 EE 70 Setiines ee 102 WLAN DHCP Connection sexesdeuteupsgresd 68 EE 97 WLAN Point to Point Connection 66 OO EOS EE 99 o Ee 34 36 EELSTEN een 39 A a Gs Birgen VER 40 P Je Tee Al Gower ouree a 26 Meteo MONICON ee 42 Prerequisites Network EE Te EE 43 Application Computer 6 Kee EE 44 Operating System cecececesseeeteeresereereeee 6 Be Ba iaa e a rsacinen cele 45 Remote Control ee 46 R Wake EE Ce RENEE OTS soea ae atited ates ucorer se eaceaat at 27 144 Absolute Tracker AT401 Index EH ere i eeh 27 Create New Reflector cccecceeeeeeeees 29 Custom Reflector sccseeseedumatdeudeceandentas 31 RS 29 EIERE ee Ed 133 lil DOME EE 135 View Details ccccceececeeeeeeeeeees 28 29 Regional Contact Addresses 00000 143 S Settings Accuracy Level geegent Sege 48 Blank EE 49 Shortcuts AT400 Remote Contro
2. Settings A Reports 3 10 1 Settings Sensor amp Controller General User Interface The menu Sensor amp Controller provides access to general system settings and status information Absolute Tracker AT401 39 Firmware version In Outdoor Mode 40 A Sensor amp Controller Firmware Version In Outdoor Mode Inclination Meteo Station cee Network Settings Power Lock Remote Control Wake Up Click on Firmware Version to display the current state of the Absolute Tracker firmware versions Depending of the current system firmware version on the system either of the following messages will be displayed Message Installed Firmware 1 1 5705 0 All system firmware compo nents are matched No actions Leica AT 401 need to be taken SN 390413 Installed Firmware 0 9 1560 0 The system firmware compo nents do not match together It Leica AT401 is highly recommended to SN 390406 update the system to the latest version Use the provided link Down load latest Update here to Your actual firmware versions do not match together This means download the actual ve rsion e that unknown errors could occur or the system could show an incorrect behavior Please download the latest update and install it via the Support Center to make sure all components are on the actual state Q Firmware Versions Mismatch Download latest Update here A system update can only be done on Administrator user le
3. 55 4 Absolute Tracker AT401 Network Settings 00 cece eee ee 56 4l Tracker SetU EE 56 4 2 Application Computer Network Settings 56 42 L WiNdOwsS XP EE 57 4 2 2 lee e Ce EE 59 4 3 Tracker Pilot Network Settings 0004 63 4 3 1 LAN Point to Point P2P with Static IP Address 64 4 3 2 LAN Network Connection DHCP 65 4 3 3 WLAN Connection with Static IP Address 66 4 3 4 WLAN Network Connection DHCP 68 4 3 5 Troubleshooting Network Problems 70 Te EE 75 ST nd E EE 75 5 1 1 Two Face Check 0 eee ee 82 5 L2 ADM CRECK i uana e Te hee eee aed gees ale 88 e le E Vd Te EE 96 6 1 Compensation Wizards 00 0 97 6 1 1 Inclination Sensor 104 6 1 2 Angle Compensation eee 104 6 1 3 ADM Compensation eee eee 111 6 1 4 ADM Offset Compensation for Custom Reflector 118 HEID EE a E oueec aan 127 E Dee Le ie CEMT u rones r i eeen E a EE 127 7 1 1 Create Support bie 128 7 1 2 Open Leica Support Website 129 7A Update Systems nates dcixvwe he Ep eE Phe bs 130 7 1 4 Export of Compensations amp Reflectors 133 7 1 5 Import of Compensations amp Reflectors 135 ee En e VE 142 Sol ADDIEGViatiONS EECH 142 8 2 Regional Contact Addresses 0 000 eee ee 143 Jee EE 144 Absolute Tracker AT401 5 1 Description of the system 1 1 General Information General This chapter contains
4. General L 4 2 Network topology C class network L TCP IP protocol setup 56 Tracker Setup After installation of the Tracker Pilot on the application computer the network connection to the AT Controller 400 needs to be configured Setup the network connection to the Absolute Tracker system The following connection types can be configured Network Connection Type LAN Connection WLAN Connection e Get Address from DHCP e Get Address from DHCP e Static IP Address e Static IP Address Refer to the chapter Operation of the Leica AT401 User Manual for details on setting up the product Application Computer Network Settings A local network topology is set up between the Application PC and the AT Controller 400 each with a unique IP address in the private network range of the class C network numbers The AT Controller 400 is delivered with a default IP address 192 168 0 1 The IP address of the application computer must De in the same range The class Cis used for private networks The full IP address consists of the Network ID 192 168 0 and the Host ID 1 254 To communicate via TCP IP protocol private networks using class C IP addresses that are not recognized on public networks and do not require coordination with IANA Internet Assigned Numbers Authority or an Internet Authority Private hosts can access external services only via application layer relays To setup the TCP IP protocol on the applica
5. Leica Tracker Pilot Reference Manual Version 1 1 English when it has to be right Seica Geosystems Introduction Purchase L Product identifica tion Symbols Trademarks Validity of this manual Congratulations on the purchase of a Leica Geosystems product To use this product in a permitted manner please refer to the detailed safety directions in the Absolute Tracker AT401 User Manual The type and serial number of the product are indicated on the type plate on the sensor unit Enter the type and serial number below and always refer to this informa tion when you need to contact your agency of Leica Geosystems autho rized Service Center Type Serial No The symbols used in this manual have the following meanings Tee Description L Important paragraphs which must be adhered to in practice as they enable the product to be used ina technically correct and efficient manner Product names are trademarks or registered trademarks of their respec tive owners Windows is a registered trademark of the Microsoft Corpo ration in the United States and other countries Adobe Reader is a regis tered trademark of Adobe Systems Incorporated in the United States and other countries This manual applies to all product series instruments Where there are differences between the various models they are clearly described Absolute Tracker AT401 Introduction Available documen tation
6. Press to confirm the proposed destination for the shortcut in the Windows Start Menu and start to install the software or press to change the destination Installing Please wait while Setup installs Tracker Pilot on your computer C Users Tester Desktop TrackerPilot exe Completing the Tracker Pilot Setup Wizard Setup has finished installing Tracker Pilot on your computer The application may be launched by selecting the installed icons Click Finish to exit Setup Launch Tracker Pilot Click to complete the installation Installation Absolute Tracker AT401 13 2 2 Tracker Pilot Updates General The Tracker Pilot software only needs to be installed once Any future updates will be included in the provided system update package Ce Only a single instance of Tracker Pilot should be installed on one applica tion computer A warning will be shown in case an existing instance of the Tracker Pilot is found on the application computer when trying to install a new instance Refer to Update System on page 130 for details on updating the system software 2 3 Tracker Pilot Uninstall General Click on the button to open the Windows Start menu Bluetooth Umgebung OPERATOR 4 IT Support UE Set Program Access and Defaults Internet Accessories gt Internet Explorer Se mp Leica Tracker Pilot i es Tracker Pilot Gil Ema EH Metrolog xG H dl Uninstall TrackerP
7. Click on the trash bin icon to delete a single measurement record ES Move the mouse over indiviual measurement values to e e display a tool tip with the measurement value and tolerance sat used where applicable Reeg Navigate back to Station 1 to optionally analyze measure _ ment details in the Measurements table ee Navigate forward to Station 2 to optionally analyze meas _ urement details in the Measurements table 57 22 Result The Report page summarizes the results of the ADM Compensation The ADM Compensation is passed within tolerance The ADM Compensation failed tolerance has been exceeded or measurement setup is insufficient Compensation Absolute Tracker AT401 115 Report 116 The Report shows detailed information about ADM Compensation 28 Configuration User Tracker IP Address Trecker Type Tracker Serial Server Version Compensation Reflector Inclination Sensor Measurement Time Accuracy Level Tempereture Pressure Humidity Results MPE Used Parameters Mar 25 2010 09 42 17 3 C RRR 1 5in OPERATOR as Advanced P2P Connection 192 168 0 1 Leica AT401 390206 3 6 70 Mar 23 2010 08 16 RRR 1 5in On 5000 ms 1 00 17 3 C 968 mBar 33 o 2 New Active Deviation Std Dev ADM Offset mm 7 174 73 000 80 174 Measurements In Id H deg V deg D mm i In 316 4967 89 0208
8. Feedback Contact Introduction Description and Format Tracker Pilot Overall comprehensive technical guide Reference to the product functions of Tracker Manual Pilot Description and Format User Manual All instructions required to operate the product to a basic level are contained in the User Manual Provides an overview of the product together with technical data and safety directions Quick Start Manual ware for checks and compensation in Standard use Intended as quick refer ence guide TPI Programmers Describes the usage and commands of Manual the Tracker Programming Interface TPI Refer to the following site for Absolute Tracker documentation and soft ware http www leica geosystems com metrology Your feedback is important as we strive to improve the quality of our documentation We request you to make specific comments as to where you envisage scope for improvement Please use the following E mail address to send your suggestions support ims leica geosystems com Leica Geosystems AG Metrology Division Moenchmattweg 5 5035 Unterentfelden Switzerland Phone 41 62 737 67 67 Fax 41 62 723 07 34 www leica geosystems com metrology Absolute Tracker AT401 3 Table of Contents Jh d e LUTTE 2 Table Of Contents enice nink ee henna e EEN 4 1 Description of the system 6 1 1 General Information weiner ee es 6 T2 Scope of This Manual ee a aw Ne
9. cluding laser trackers Local Positioning Technology LPT based systems hand held scanners 3D software and high precision total stations Those who use Leica Metrology products every day trust them for their dependability the value they deliver and the world class service amp support that s second to none Precision reliability and service from Leica Geosystems Me trology When it has to be right 778016 V1 1 4en 2010 Copyright Leica Geosystems AG Unterentfelden Switzerland For more information please contact info metrology leica geosystems com L _ d when it has to be right Seica Geosystems
10. 1 5361 0 wi Updates Installed Successfully Your system is up to date Restart TrackerPilot Click on Restart TrackerPilt to shutdown the Tracker Pilot Restart the applica tion the application to re connect to the Absolute Tracker Refer to Tracker Pilot Startup on page 17 on details on launching the Tracker Pilot The following items should be checked in case the Tracker Pilot does not allow to update the system or an update fails e AT Controller 400 connected to mains power e AT Controller 400 powered and booted up e LAN connection between application computer and AT Controller 400 established e Sensor cable connected to AT Controller 400 and Absolute Tracker AT4O1 Retry to start the update after checking these points If the update keeps failing generate a support file and send it to you local Leica Geosystems representative 7 1 4 Export of Compensations amp Reflectors General L File name amp loca tion Help The compensations and reflectors stored on the Absolute Tracker AT401 can be exported to an application computer for the following purposes e Data backup of compensations and reflectors e Sharing common reflector definitions between different Absolute Tracker AT401 systems This function is only available to user level Advanced Exported compensations and reflectors are stored into two separate files Absolute Tracker AT401 133 Procedure 134 Compensa AT401_
11. 42 for details on the meteo parameters Displays the active reflector Refer to Reflectors on page 77 tor details on reflectors Displays the active compensation Refer to Compensations on page 32 for details on compensations Displays the selected measurement time The result is an average of the measurements taken during the selected time Default meas urement time is 2000 ms A measurement time of 2 2000 ms is recommended for check measurements To start a check select the desired wizard from the Check menu on the Absolute Tracker AT401 81 5 1 1 Two Face Check General The Two Face check routine verifies the system geometry horizontal and vertical collimation Large ambient temperature changes may result in significant two face check deviations Check procedure Two Face measurements consist of the following 2 step process 1 Measurement of three points ideally on a line at the height of tilting axis of the Absolute Tracker AT401 2 Measurement of one point at a steep angle ideally points at floor level Recommended The recommended setup for the Two Face check is shown below setup eR esi wooo oo 82 Absolute Tracker AT401 Check Procedure step by step Check Setup the Absolute Tracker system according the setup sketch shown above Ensure the Absolute Tracker system Is warmed up and acclimatized to the envi ronment 3 Navigate to the main page and select the
12. 6 1 3 REESEN eater Bee vee Oe ea 6 2 Installaton 0 0 eee 8 2 1 Tracker Pilot Software 00 cee ee 8 2 WINDOWS AP ca ee See Seine aes ee anak E a 8 212 WINDOWS EE 11 2 2 Tracker Pilot Updates 14 2 3 Tracker Pilot Uninstall 0 0 0 cc eee eee 14 2 4 Absolute Tracker System Software 15 3 User Interface 0 0 cee 16 3 1 User Levels 2 av 65 e484 wer eden ev ewes Od Eee eases 16 3 2 Tracker Pilot Startup 00 2 eee 17 3 3 Select Sensor Page 0c ee es 19 3 4 Keyboard amp Remote Control Shortcuts 21 3 5 Main Pab ac Web erg hehe eda oe a bee Se bees 22 3 6 POWER SOUC EE 26 3 7 ReETICClOIS y re oan Seeger EN se Lee eee wee te 27 3 7 1 Reflectors on Standard User Level 27 3 7 2 Reflectors on Advanced User Level 28 3 8 COMPEMNSALONS EE 32 3 8 1 Compensations on Standard User Level 33 3 8 2 Compensations on Advanced User Level 35 3 9 Measurement Tme es 38 SB LOCOMTISULALION E ee wie eh ee Er e 39 3 10 1Settings Sensor Er Controller 39 3 10 2Settings Tracker blot 48 3 10 3Viewing PDF Report 50 R IEREN 51 2 1 2ZFINd Reflector ewes doc eee eet ete yew ER etm ee dex 52 3 130verview Camera ee 52 3 14Messages amp Impediments 000s 53 S14 LIMpPeGiIMenit eins vce ene a bs ee ae ew ina 54 3 14 2Warning amp Error Messages 00005 54 3 14 3Exception Handling
13. BRR 1 5in reflector to use for the check No SNe O Select the compensation to use for the 2010 04 29 15 37 check Angle 18 4 C RRR 1 5i Select the measurement time to use Measure Time 5000 ms CS A measurement time of 2000 ms is recommended for checks Initialize F3 the system E Ensure a reflector is in the field of view when starting the initialization process A message is displayed during the initiali zation process Piease wait initializing Start the Two Face Check wizard A Check Two Face ADM Move the reflector to the first point to measure The DRO window and the sketch provide guidance to find the correct posi tion kW Press the Measure F2 button 10 Repeat steps 8 amp 9 for all other positions Additional points can be added optionally Optionally analyze measurement details in the Measurements table delete or repeat measurements accordingly 12 Navigate to the Report page when all measurements are taken 13 The Two Face Check is marked as Passed or Failed depending on the measurement results Click on the Show Report icon to view detailed results of the Two Face Check Absolute Tracker AT401 83 84 Finish the Two Face Check process The PDF Report will be generated A message is displayed during this process Absolute Tracker AT401 Check Measurements table Result Check All measurements taken are listed in the Measurements tabl
14. Click into the image with the mouse pointer to move the Absolute Tracker to the selected position Lock option disabled The Absolute Tracker AT401 will not try to lock onto a reflector when clicking into the image with the mouse pointer The OVC window stays open until closed manually Lock Lock option enabled The Absolute Tracker AT401 will try to lock onto a reflector when clicking into the image with the mouse pointer The OVC window will be closed automatically The DRO status will change to green when a reflector has been found eg A message is displayed during the lock on process Close the OVC window A reflector in the field of view will be locked if the lock option is ticked once the OVC window is closed Ce The measurement status will only become ready green when the OVC window has been closed While the OVC window Is open the measure ment status in the DRO window will be not ready red Ce In case the Absolute Tracker AT401 is in face 2 the sensor will switch to face 1 when turning on the OVC 3 14 Messages amp Impediments General Two different types of status information are shown to the user User Interface Absolute Tracker AT401 53 Impediment An tool tip will display an impediment whenever a button is disabled grayed out describing the reason for the impediment i e Tracker not initialized Pop up message A warning or error message will be displayed during a user Operation if an excep
15. Click on Units to change of dimensions displayed in the Tracker Pilot Units Length mm Format 0 000 HE Arike ldo el Format 0 0000 E L ee RRE roma oo E eeng EN nt EE Humidity EE Format 0 E ge bel rem SIS Click on the button to change the length unit A drop down menu opens displaying a list of available units Meter m Millimeter mm Default Micrometer mu Foot foot Yard yard Inch inch Click on the button to change the angle unit A drop down menu opens displaying a list of available units e Radian rad e Degree deg Default e Gon gon Click on the button to change the temperature unit A drop down menu opens displaying a list of available units e Degree Celsius C Default e Degree Fahrenheit F Click on the button to change the pressure unit A drop down menu opens displaying a list of available units Millibar mBar Default Hektopascal hPa Kilopascal kPa Millimeter column of mercury mmHg Pounds per square inch PSI Inch column of water InH gt 0 Inch column of mercury InHg Click on the button to change the humidity unit A drop down menu opens displaying a list of available units e Relative Humidity Default User Interface Absolute Tracker AT401 49 kamen Click on the button to change the time unit A drop down menu opens displaying a list of available units e Milliseconds ms Default e Seconds s e Minutes min e Hours h Increase displa
16. Click on the Cancel button to cancel the wizard and delete all measurements Ce Cancelling the process deletes all measured data Category Detail Information Information Configuration Measurements Passed Failed Name Comment User Windows User Login amp Tracker Pilot Login Tracker click on the link for further details IP Address Tracker Type Absolute Tracker AT401 Serial Number AT Controller 400 Server Version Active Compensation click on the link to display the active compensation parameters Active Reflector click on the link to display the details of the active reflector Inclination Sensor state Measurement Time Accuracy Level Temperature Pressure Humidity Sketch Side View Sketch Top View Measurement Details Table Within the Report page of the Tracker Pilot tooltips are still displayed in sketch view and measurement details can be viewed as well Absolute Tracker AT401 Check PDF report Check Use the Back button to navigate back to the measurements page i e to delete measurements or take additional measurements on Station 2 In case measurements from Station 1 have to be remeasured the whole station has to be repeated When returning to the Report page the report will be updated dynamically The generated PDF report is saved in the following location on the appli cation computer Windows XP C Documents and Settings Local User Applica tion Data Tracker Pilot Reports
17. Connection N feica S N 390406 192 168 0 1 Gecepstoms Select user to login Logged in as Standard A Standard A Advanced S Ss E A TE Absolute Tracker AT401 17 Login page 18 Logs in with Standard user level A password is not Standard required A Logs in with Advanced or Administrator user level A Advanced i password is required Clicking on the icon for Advanced user level opens the login page aio x N Leica AT401 P2P Connection feica SIN 390406 192 168 0 1 Geosystoms Select user to login Logged in as Standard A Advanced is Please enter password Cancel Coan Back Ion Jee ooo Please enter password Enter the password The following passwords are set by default Standard no password required Administrator Administrator Refer to Passwords on page 44 for details on setting user defined pass words Absolute Tracker AT401 User Interface 3 3 Select Sensor Page General One connection is available by default e Point to point connection wired DoR Select Sensor SP New Connection Big P2P Connection lel Leica AT401 a gt 192 168 0 1 The following controls are available on the Select Sensor page nn The default connection for Tracker Pilot or other third WM Leica AT401 party applications Is a point to point connection Click SY een on the icon to establish a point to point connection wi
18. Controller 400 loads saved network connection settings and tries to establish a network connection Not Active WLAN disabled Network Settings Absolute Tracker AT401 63 4 3 1 LAN Point to Point P2P with Static IP Address General L P2P shortcut 64 The wired point to point P2P connection is the default factory setting of the Absolute Tracker system To reset this connection from a different setting select the following gia LAN Configuration MAC 00 50 C2 A7 72 3B Network Mode IP Address 192 168 0 Ad Get Address from DHCP IP Mask 255 255 255 0 Static IP Address Gateway Address D 9 0 o On activating the settings the current connection will be closed and you have to reconnect Apply Required settings Network Mode Static IP Address IP Address IP Address in C Class network range i e 192 168 0 1 IP Mask 255 255 255 0 Gateway Address 0 0 0 0 Ensure all setting are entered correctly and click Apply to activate the point to point P2P connection The LCD display of the AT Controller 400 displays a message while the system is being reconfigured Tracker Pilot will return to the Select Sensor page The IP Address will be displayed on the LCD screen of the AT Controller 400 Bez AL i mer 0 0 0 0 192 168 0 1 Click on the following icon to connect to the AT Controller 400 P2P Connection Leica AT401 152 168 0 1 Ensure the entered IP
19. Details Table Compensation Absolute Tracker AT401 117 PDF report Within the Report page of the Tracker Pilot tool tips are still displayed in sketch view and measurement details can be viewed as well Use the Back button to navigate back to the measurements page i e to delete measurements or take additional measurements on Station 2 In case measurements from Station 1 have to be remeasured the whole station has to be repeated When returning to the Report page the report will be updated dynamically The generated PDF report is saved in the following default location on the application computer unless its saved into a personal folder manually Windows XP C Documents and Settings Local User Applica tion Data Tracker Pilot Reports Windows Vista C Users Local User AppData Roaming Tracker Pilot Reports Windows 7 C Users Local User AppData Roaming Tracker Pilot Reports Refer to Viewing PDF Reports on page 50 for details on viewing saved Compensation reports 6 1 4 ADM Offset Compensation for Custom Reflector General Compensation procedure 118 All glass prism reflectors cause a refraction of the laser beam in the glass body This results in a lag of the path of the laser beam The ADM Offset Compensation for Custom Reflectors routine verifies this additional path of the ADM beam ADM Offset Compensation measurements consist of the following 2 step process 1 Measurement of two fixed poi
20. Link Layer Topology Discovery Responder Install Uninsta Properties Description Transmission Control Protocol Intemet Protocol The default wide area network protocol that provides communication across diverse interconnected networks AK NS XS OK Cancel Highlight the Internet Protocol Version 4 TCP IPv4 and click on Petes To setup a point to point P2P connection select the radio button Use the following IP address Internet Protocol Version 4 TCP IPv4 Properties P xs General You can get IP settings assigned automatically if your network supports this capability Otherwise you need to ask your network administrator for the appropriate IP settings Obtain an IP address automatically Use the following IP address IP address 192 168 0 2 Subnet mask 255 255 255 0 Default gateway Obtain DNS server address automatically Use the following DNS server addresses Preferred DNS server Alternate DNS server E Validate settings upon exit Enter an IP address in the class C network address range i e 192 168 0 2 for the point to point connection Click into the Subnet mask field below the Subnet address 255 255 255 0 will fill in automatically Ensure the entered IP address for the application computer is different from the IP address of the AT Controller 400 Close the dialog by clicking and Oe Close the Contro
21. MPE Used Measurements Id H deg V deg D mm H Dev deg V Dev deg D Dev mm The Report shows detailed information about Two Face Check 28 Mar 24 2010 15 37 Two Face Check OPERATOR as Standard P2P Connection 192 168 0 1 Leica AT401 390208 3 6 70 Mar 24 2010 13 52 RRR 1 5in On 2000 ms 1 00 16 4 C 968 mBar 33 21 EE bii ed kee A as Le e Kal bal ne i BI a D a a ee ee ee H ee ee ee ae 1 272 9861 90 2058 2080 567 0 007185 0 021851 0 03792 2 272 8549 90 1961 20184 202 0 007278 0 021072 0 03985 3 272 7816 90 1894 40323 6856 0 007331 0 020038 0 03766 4 274 8662 125 0389 2286 350 0 009224 0 022343 0 03210 The following actions can be taken Save the Report as PDF file This button can be used to save a copy of the PDF Report in a personal folder Print the Report Use the Back button to navigate back to the measurements page Click on the Finish button to generate the PDF report and finish the Two Face Check process Click on the Cancel button to cancel the wizard and delete all measurements Ce Cancelling the process deletes all measured data Absolute Tracker AT401 Check Category Detail Information Information Passed Failed Name Comment Configuration User Windows User Login amp Tracker Pilot Login Tracker click on the link for further details IP Address Tracker Type Absolute Tracker AT401 Serial Number AT Controller 400
22. Moving the mouse over a compensation element displays the View icon Click on the icon View to display the details of the selected compensation record Displays the details about the selected compensation record Compensation date Name max 32 characters User defined comment max 128 characters Reflector type Tracker compensation parameter details Click on the icon Delete to permanently delete the selected compensation record from the Absolute Tracker Ce The currently active compensation record can not be deleted Click on New Angle Compensation to access the Angle Compensation wizard Refer to Angle Compensation on page 104 for details on the Angle Compensation procedure Click on New ADM Compensation to access the ADM Compensation wizard Refer to ADM Compensation on page 111 for details on the ADM Compensation procedure Apply changes and return to the main page of Tracker Pilot A message is displayed while the data on the Absolute 1 Tracker AT401 is updated 36 Absolute Tracker AT401 User Interface Compensation details User Interface Refer to Compensation on page 96 for details on compensation wizards and procedures Refer to Export of Compensations amp Reflectors on page 133 for details on exporting reflectors Refer to Import of Compensations amp Reflectors on page 135 for details on importing reflectors On Advanced user level the fully detailed compensati
23. Server Version Active Compensation click on the link to display the active compensation parameters Active Reflector click on the link to display the details of the active reflector Inclination Sensor state Measurement Time Accuracy Level Temperature Pressure Humidity e MPE Maximum Permissible Error Used in Measurements e Sketch Side View e Sketch Top View e Measurement Details Table Ce Within the Report page of the Tracker Pilot tooltips are still displayed in sketch view and measurement details can be viewed as well a Use the Back button to navigate back to the measurements page i e to delete measurements or take additional measurements When returning to the Report page the report will be updated dynamically PDF report The generated PDF report is saved in the following location on the appli cation computer Windows XP C Documents and Settings Local User Applica tion Data Tracker Pilot Reports Windows Vista C Users Local User AppData Roaming Tracker Pilot Reports Windows 7 C Users Local User AppData Roaming Tracker Pilot Reports Check Absolute Tracker AT401 87 Refer to Viewing PDF Reports on page 50 for details on viewing saved Check reports 5 1 2 ADM Check General Check procedure Recommended setup 88 The ADM check routine verifies the zero point offset of the ADM in rela tion to the origin of the Tracker coordinate system by measuring two fixed poi
24. Start Menu Programs Leica Tracker Pilot TrackerPilot exe Cancel Tracker Pilot will now be installed into the displayed folder 10 Absolute Tracker AT401 Installation ie Setup Tracker Pilot Version 1 3 1 122 Completing the Tracker Pilot Version 1 3 1 122 Setup Wizard Setup has Finished installing Tracker Pilot Version 1 3 1 122 on your computer The application may be launched by selecting the installed icons Click Finish to exit Setup Launch Tracker Pilot Click to complete the installation 2 1 2 Windows 7 General The provided Tracker Pilot product CD contains the installation files for the Tracker Pilot software Insert the CD into the CD drive of the applica tion PC the Autorun should launch the Installer menu automatically Start the application AT401Software exe manually in case the AutoPlay option is not activated on your PC AT401Software Getting Started with a New Leica Absolute Tracker 47401 1 Configure the Leica Absolute Tracker 47401 according to the 47401 Absolute Tracker User Manual 2 Click Tracker Pilot to install the Tracker Pilot from this CD and follow the instructions on the screen Note do not install to a network drive because depending on network rules for users operation of Tracker Pilot cannot be 100 guaranteed v Copyright 2010 Leica Geosystems All Rights Reserved This program is protected by inter national copyright laws as descri
25. Tracker AT401 will still provide its full functionality but the achievable accuracy might be reduced S Disabling the inclination sensor will not be stored persistently By default the inclination sensor will enabled at startup of the Absolute Tracker Meteo Monitor Click on Meteo Monitor to access the meteo station settings 42 Absolute Tracker AT401 User Interface Automatic Readings amp Manual Settings Automatic Readings Select this radio button to allow the instrument to EE automatically read the meteo parameters from the built in Meteo Monitor e 53 y Ai Manual Settings d r E Temperature Cc Pressure mBar Humidity KA The following controls are available Click on the icon Manual Settings to manually input environmental parameters The state change will be applied instantly Click into the input fields and enter the values for ambient temperature pressure and humidity manu ally The changes need to be applied manually by clicking OK Click on the icon Automatic Readings to read the envi ronmental data from the Meteo Monitor automatically The state change will be applied instantly Automatic Readings Sg Connecting and disconnecting an external temperature sensor will be recognized automatically Wome To achieve highest possible measurement accuracy it is highly recom mended to determine the ambient temperature using the provided external temperature sensor Using the internal temp
26. address for the AT Controller 400 is different from the IP address of the application computer A keyboard shortcut allows to reset any network connection to a point to point connection without launching Tracker Pilot When starting the AT Controller 400 wait for the following message on the LCD screen lt Searching IP gt ATCAOO 1 7 Leica Geosystems Absolute Tracker AT401 Network Settings While the message Searching IP is displayed press and hold the scroll button of the AT Controller 400 for 10 seconds The following message will be displayed Changing LAN Configuration to 152 165 0 1 After the AT Controller 400 has been reconfigured the connection page displays the IP address 192 168 0 1 Click on the P2P Connection icon to connect to the Absolute Tracker 4 3 2 LAN Network Connection DHCP General Network Settings The Absolute Tracker system can be integrated into a company network environment In this case the IP Address of the AT Controller 400 will be provided by a DHCP server in the relevant network To configure the AT Controller 400 to obtain an IP Address from DHCP ol LAN Configuration MAC 00 50 C2 A7 72 3B Network Mode IP Address Get Address from DHCP Static IP Address dere Gateway Address Co On activating the settings the current connection will be closed and you have to reconnect Apply Required settings Network Mode Get Address from DHCP All input fie
27. detailed information of the required WLAN encryption settings Changing the IP settings and encryption mode will be stored persistently After a restart of the Absolute Tracker system the WLAN parameter settings will remain Ensure all setting are entered correctly and click Apply to activate the network connection The LCD display of the AT Controller 400 displays a message while the system is being reconfigured Tracker Pilot will return to the Select Sensor page The IP Address will be displayed on the LCD screen of the AT Controller 400 i e Not encrypted fl Gas AE dl or 21 33 101 22 lt 0 0 0 0 Q SS AE wal wr 2 1 33 1 01 22 ia 0 0 0 0 Encrypted A new connection needs to be created using the IP address displayed on the LCD screen of the AT Controller 400 Refer to New Connection on page 19 for details on creating a new connection Absolute Tracker AT401 67 4 3 4 General IP Address settings Encryption 68 WLAN Network Connection DHCP The Absolute Tracker system can be operated in a wireless network envi ronment A wireless access point is required for this configuration In this case the IP Address of the AT Controller 400 will be provided by a DHCP server in the relevant network Refer to Network Settings on page 43 for details on WLAN restrictions in certain countries To activate the WLAN communication on the AT Controller 400 tick the Activate WLAN bo
28. from time to time During the manufac turing process the product parameters are carefully determined As mentioned above the values can change and it is highly recommended to check or adjust the product in the following situations e Before the first use of the product e Before taking high precision measurements e After long transportations e After long working periods e After long storage periods e Ina high or low temperature environment Before starting to work the product has to become warmed up and accli matized to the ambient temperature especially if the product has been stored under different temperature conditions Ensure sufficient acclima tization to the environment before taking precision measurements The systems needs to be initialized before a check wizard can be started A check can be performed in either of the indoor or outdoor modes Check Wizards General Process Check The following check wizards can be selected Standard Advanced Two Face Check Za Za ADM Check vA Za All check wizards consist of a 2 step process e Measurement process e Report process Therefore all check pages share the same layout The wizard starts with the measurement page s to take all required measurements where on Absolute Tracker AT401 75 Sketches 76 the last page of the wizard the measurement results can be analyzed and printed or archived as required Dynamic sketches will guide the
29. function searches for a reflector within a defined search area and locks onto a target found The behavior of the Find Reflector function depends on the PowerLock state On Find Reflector searches with PowerLock within its field of view without moving the Absolute Tracker AT401 Off Find Reflector performs a spiral search within a prede fined search area The size of the search window is 9 5 approximating the field of view of PowerLock Procedure Click on the Find Reflector icon amp The following message is displayed during the search process Please wait finding reflector 3 13 Overview Camera General The monochrome Overview Camera enables visualization of reflectors Activation Click on the Overview Camera icon in the Absolute Tracker controls to 52 activate the live video image This opens the following dialog window Live O C view Brightness Contrast The following controls are available Absolute Tracker AT401 User Interface Item Description Drag the button on the panel to move the Absolute Tracker The rotation speed increases the further the button is moved away from the center Release the button to stop the movement Brightness Adjust the brightness of the view image by moving the slider up or down This setting will be stored persist ently Contrast Adjust the contrast of the view image by moving the slider up or down This setting will be stored persist ently
30. general information about the usage of the Leica System overview 1 2 General Software version 1 3 Tracker Pilot software The Leica Tracker Pilot provides a graphical user interface to the Leica Absolute Tracker AT401 for checks compensations and system mainte nance processes a Absolute Tracker AT401 b application computer running Tracker Pilot c AT Controller 400 Scope of this manual This Reference Manual is a part of the product It includes important information on installing and running the software This manual is based on Tracker Pilot major version 1 1 Prerequisites Application computer require ments Operating system The Tracker Pilot running on the application computer requires the following 1 PC with 300MHz or higher processor clock speed recommended 2 150 MB free hard disk capacity 3 128 MB RAM 4 100 MBit Ethernet LAN Network Interface RJ45 Tracker Pilot supports the following operating systems 1 Windows XP 32 bit Windows XP 64 bit Windows Vista 32 bit Windows Vista 64 bit Windows 7 32 bit Windows 7 64 bit Om P W NN Absolute Tracker AT401 Description of the system Software To view or print PDF Reports Adobe Reader 9 or higher is required Windows user It is not possible to install or run the Tracker Pilot under the Windows account control Guest account Laser Tracker amp The Tracker Pilot supports the following Leica Geosystems La
31. of the import The Tracker Pilot returns to the Support Center page after the import has finished Absolute Tracker AT401 Help Import Compensa To import compensations select the following tions Please choose a file i 2 xi Look in Ice Support DI e eh ES My Recent Documents Desktop 47401 390208 Mar 27 2010 15 59 Compensations 47401 390208 Mar 27 2010 15 59 Reflectors 2 My Documents K gr saum on AUNTLADSA W e Des Fie name 401 390208 Mar 27 2010 15 58 Compensations zl Places Files of type Compensations amp Reflectors DI Cancel E Select the desired item and click Open The following screen appears Tracker Pilot PZP Connection Leica AT401 P2P Connection SN 390406 192 168 0 1 Support Center Import Compensations 9 Total 1 of maximum 25 items 3 2010 03 19 15 10 2010 03 19 15 10 fe 2010 01 29 15 37 Te 2 29 15 37 Angle 18 4 C RRR 1 5in Angle 18 4 C RRR 1 5in 2010 04 29 15 37 SN 2010 04 29 15 37 a a b c a Trash bin b Reflectors currently stored on the Absolute Tracker AT401 c Reflectors contained in the import file The following actions can be taken e Drag amp drop a compensation from the import file c onto the AT401 AT401 b to mark this compensation to be imported to the sensor e Drag amp drop a compensation from the Absolute Tracker AT401 b onto the Trash bin to mark this compensation to be r
32. pre installed on the system No user installation or modification is required unless the system requires an update to a newer system software version Refer to Update System on page 130 for details on updating the system software Absolute Tracker AT401 15 3 User Interface General This chapter contains general information about how to use the Leica Tracker Pilot software 3 1 User Levels General The Tracker Pilot has three different user levels User User Level Functionality ie Add and delete connections Activate reflectors and compensa tions Checks Network Settings Basic Measurements Create Support File Advanced Advanced Add and delete connections Change Accuracy Settings View reflector and compensation details Activate and create reflectors and compensations Checks Network Settings Basic Measurements Update Absolute Tracker system Create Support File Export and Import reflectors and compensations Administrator Administrator Add and delete connections e Change Accuracy Settings e View reflector and compensation details e Activate and create reflectors and compensations e Checks e Network Settings e Basic Measurements e Update Absolute Tracker system e Create Support File e Export and Import reflectors and compensations e Manage passwords 16 Absolute Tracker AT401 User Interface 3 2 Tracker Pilot Startup General User login User Interface To launc
33. sketch shown above CS It is recommended to setup the Absolute Tracker AT401 at least 1300 mm height from the ground tilting axis height 2 Ensure the Absolute Tracker system is warmed up and acclimatized 3 Navigate to the main page and select the BRR L5in reflector to use for the compensation N sN O Select the compensation to use for the 2010 04 29 15 37 compensation Angle 18 4 C RRR 1 5i Select the measurement time to use Measure Time 5000 ms Ce measurement time of 5000 ms is recommended for compensations WM Initialize F3 the system a Cs Ensure a reflector is in the field of view when starting the initialization process A message is displayed during the initiali zation process Please wait initializi ng 7 Navigate to the Compensations page lt 2010 04 29 15 37 Angle 18 4 C RRR 1 5ii Start the Angle Compensation s New Angle Compensation E Click on the Measure button to start the inclination index determination The process returns the Inclination Index measurement successful values after a successful measurement Inclination Index L 5 729578 deg Inclination Index C 11 459156 deg due to unstable conditions repeat step 6 In case the inclination measurement fails x RE Navigate to the Angle Measurements 11 Move the reflector to the first point to measure The DRO window and the sketch provide guidance to find the correct posi tion 12 Press
34. user through the check process The sketches contain a top view and a side view to the measurement scene guiding the user to the required position The current position of the locked reflector and the target positions for the measurement be will be updated dynamically through the whole measurement process The current beam direction is represented by a colored line which reflects the current state shown in the DRO window C d a f b LI a Top view of measurement setup b Side view of measurement setup c Nominal position d Scale e Instrument position f Measured position Absolute Tracker AT401 Check Tool tips Dynamic tool tips provide additional information on the required posi tions check measurements and accuracy information related to the measurements Tool Tip Id H deg V deg D mm Std Dev mm 1 0 0000 90 0000 2000 000 H deg V deg D mm Std Dev mm 32 0 6902 89 6274 2019 734 0 29601 Std Dev 0 0146 0 0084 0 452 Accuracy 1 0000 2 0000 33 676 0 00000 16 6 C 346 mBar Temperature Pressure Humidity 0 Nominal Position Point ID Required Horizontal Angle Required Vertical Angle Required Distance Measured Position Point ID Measured Horizontal Angle Measured Vertical Angle Measured Distance Standard Deviation for each component a posteriori Accuracy a priori Temperature Pressure Humidity Data Read Out DRO window A Data Rea
35. your Leica Geosystems representative for further details on wireless network regulations Ce In France outdoor usage of the WLAN functionality is not permitted Only use WLAN indoors Passwords Click on Password to access the password settings page Sen This function is only available to Advanced and Administrator user level Password for Advanced user Advanced Old password Change password for user New password level Advanced Repeat new password 44 2 Absolute TrackerAT401 User Interface Password for Advanced user Administrator ae gt Change password for user New password level Advanced Repeat new password Apply Default m Reset password for user Password for Administrator user level Adva nced Genen d Change password for user level Administrator New password Repeat new password The following controls are available Type in the old password for the relevant user level Type in the new password for the relevant user level Repeat new password Repeat the new password for the relevant user level Click Apply to apply the changes Click Default to reset the password for the Advanced Default Dt user level back to the default password Return to the main page of Tracker Pilot Ce Passwords will be stored on the AT Controller 400 Therefore passwords only apply to the individual AT Controller 400 Le In case of a lost Administrator user level password please contact you
36. 0 m from the sensor Compensation Wizards The following compensation wizards can be selected ADM Compensation a A maximum number of 25 compensation records can be stored on the Absolute Tracker AT401 In case the maximum number of compensations has been reached a warning message will appear Refer to Export of Compensations amp Reflectors on page 133 for details on exporting compensations to an application computer Refer to Import of Compensations amp Reflectors on page 135 on details on deleting compensations from the Absolute Tracker AT401 All compensation wizards consist of a 2 step process e Measurement process e Report process Therefore all compensation wizard pages share the same layout On the first page of the wizard all measurements are taken where on the second page the measurement results can De analyzed and printed or archived as required Dynamic sketches will guide the user through the compensation process The sketches contain a top view and a side view to the measurement scene guiding the user to the required position The current position of the locked reflector and the target positions for the measurement be will be updated dynamically through the whole measurement process The current beam direction is represented by a colored line which reflects the current state shown in the DRO window Absolute Tracker AT401 97 98 Top view of measurement setup Side view of measureme
37. 003 0 0065 0 0333 0 020 5 239 0608 89 2310 3008 075 0 016 0 0065 0 0228 0 009 6 237 1958 89 4301 4668 120 0 012 0 0062 0 0132 0 015 The following actions can be taken Compensation Absolute Tracker AT401 107 Result LOS Click on the point ID to open a pop up window showing details about the selected measurement record Click on the trash bin icon to delete a single measurement record Ce During Angle Compensation only the actual last record in the list can be deleted sony Move the mouse over indiviual measurement values to rr display a tool tip with the measurement value and tolerance A used where applicable 57 22 U A The Report page summarizes the results of the Angle Compensation The Angle Compensation is passed within tolerance The Angle Compensation failed tolerance has been exceeded or measurement setup insufficient Absolute Tracker AT401 Compensation Report Compensation The Report shows detailed information about the Angle Compensation E 0 0001 0 0002 0 0001 0 0000 0 0001 0 000 0 003 0 002 0 006 0 005 wo Passed Name 2010 10 26 15 25 Comment Angle 24 5 C RRR 1 5in Configuration User OPERATOR as Advanced Tracker P2P Connection Tracker Type Leica AT 401 Server Version 3 7 27 Compensation 2010 06 21 15 32 Inclination Sensor On Measurement Time 2000 ms Temperature 24 5 C Humidity 27 Results MPE Used 82
38. 1 or AT Controller 400 battery capacity between 21 40 E The tool tip will show the exact battery capacity Absolute Tracker AT401 or AT Controller 400 battery capacity between 41 60 C The tool tip will show the exact battery capacity Absolute Tracker AT401 or AT Controller 400 battery capacity between 61 80 C The tool tip will show the exact battery capacity Absolute Tracker AT401 or AT Controller 400 battery capacity between 81 100 C The tool tip will show the exact battery capacity The sensor unit always needs to be equipped with an internal battery GEB241 independently from the power source This battery may be empty but should be charged from time to time to avoid damage to the battery The Absolute Tracker allows to change both batteries during operation without the need to shutdown the system Refer to chapter 3 4 4 Hot Swapping of the Absolute Tracker AT401 User Manual for details on hot swapping of batteries Absolute Tracker AT401 User Interface 3 7 Reflectors General The Reflectors page allows to view and maintain reflector definitions The following functions are available View Reflector definition 3 7 1 Reflectors on Standard User Level Activate reflector Click on the Status Bar element for Reflector to access the Reflectors Dage RRR 1 5in S N 3316 The reflector page for the user level Standard looks as follows Tracker Pilot P2P Connection
39. 192 168 0 1 Support Center Import Reflectors 9 Total 7 of maximum 25 items z RRR 1 5in RRR RRR15 RRR15 a a Counter of remaining capacity of records on the Absolute Tracker AT401 Absolute Tracker AT401 141 8 Appendix 8 1 Abbreviations The following abbreviations may be found in this manual connecting telecommunication equipment TCP es 142 Absolute Tracker AT401 Appendix 8 2 Regional Contact Addresses China Hexagon Metrology Qingdao Co Ltd 188 Zhuzhou Road 266101 Qingdao China P R China Phone 86 532 8870 2188 Fax 86 532 8870 3060 Germany Hexagon Metrology GmbH Vertrieb Triebstrasse 14 80993 Munchen Deutschland Tel 49 89 14 98 10 0O Fax 49 89 14 98 10 33 Italy Hexagon Metrology SpA Via Bizzozzero 118 20132 Cormano MI Phone 39 02 6154 111 Fax 39 02 6150 473 Switzerland Leica Geosystems AG Metrology Division Moenchmattweg 5 CH 5035 Unterentfelden Phone 41 62 737 67 67 Fax 41 62 737 68 33 USA Hexagon Metrology Precision Center 9424 E 37th Street North Suite 220 Wichita KS 67226 Toll free 1 866 756 6763 Phone 1 316 634 0856 Fax 1 316 634 0878 Appendix France Hexagon Metrology SAS Service Client Leica Immeuble Le Viking 32 Avenue La Baltique 91978 Courtaboeuf C dex France Phone 33 O1 69 29 12 00 Fax 33 01 69 29 00 32 Great Britain Hexagon Metrology Ltd Davy Avenue Knowlhill Milton Keynes MK5 8
40. 1_xxxxxx_MMM dd yyyy_hh mm ss Compensations tions e XXXXXX representing the 6 digit serial number of the Absolute Tracker AT401 e MMM dd yyyy_hh mm ss representing the date and time of the export Reflectors AT401_xxxxxx_MMM dd yyyy_hh mm ss Reflectors e Max representing the 6 digit serial number of the Absolute Tracker AT401 MMM dd yyyy_hh mm ss representing the date and time of the export The exported files are stored in the following location by default Windows XP C Documents and Settings Local User Applica tion Data Tracker Pilot Support Windows Vista C Users Local User AppData Roaming Tracker Pilot Support Windows 7 C Users Local User AppData Roaming Tracker Pilot Support Compensations and reflectors can also be imported from different loca tions i e personal folders or portable memory devices Click on the followings icon to import compensations and reflectors Import Compensations amp Description Reflectors Import the following items from the application computer e Compensations e Reflectors be Import Compensations or Reflectors Import compensations or reflectors from an specified file To import reflectors select the following Absolute Tracker AT401 Help Help Please choose a file 2 x Lookin Ose zs KE My Recent Documents Desktop e My Documents er saum on AUNTLADSA zem e i APT Fie name AT401 390208 Mar 27 2010 15 59 Reflect
41. 2 for details on compensations Measure Time Displays the selected measurement time The 5000 ms result is an average of the measurements taken during the selected time Default meas urement time is 5000 ms A measurement time of 2 5000 ms is recommended for compensation measure ments a A minimum measurement time of 2000 ms is required for compensa tions In case a measurement time of lt 2000 ms Is entered the measure ment time will be changed to 5000 ms when a compensation wizard is started Selection To start a compensation navigate to the Compensations page and select the required compensation wizard Navigate to the Compensations page lt 2010 04 20 15 37 Angle 18 4 C RRR 1 5i Select the required compensation wizard lt 4 New Angle Compensation Refer to Procedure step by step o ia page 106 for details on the Angle C a sation Refer to Procedure step by step on lt New ADM Compensation page 113 for details on the ADM Compen sation Compensation Absolute Tracker AT401 103 6 1 1 Inclination Sensor General The Absolute Tracker AT401 can either be compensated with enabled or disabled inclination sensor The actual state of the inclination sensor will be associated with the compensation record Inclination Sensor Compensation Record marked Enabled full corrections Inclination Sensor On Disabled no corrections Inclination Sensor Off Inclination sensor Th
42. 3205 456 2 In 137 1845 89 5978 3321 652 Measurements Out Sketch meest Eleng 1 Out 128 9211 89 0704 2869 968 2 Out 130 3532 89 9122 9248 844 Absolute Tracker AT401 Compensation The following actions can be taken Save the Report as PDF file This button can be used to save the PDF Report in a personal folder In this case no copy of the report will be saved into the default location fe Print the Report ZC Use the Back button to navigate back to the measurements lt Back page Click on the Finish button to generate the PDF report and _ finish the ADM Compensation process Click on the Cancel button to cancel the wizard and delete all measurements Ce Cancelling the process deletes all measured data Category Detail Information Information Passed Failed Name Comment User Windows User Login amp Tracker Pilot Login Tracker click on the link for further details IP Address Tracker Type Absolute Tracker AT401 Serial Number AT Controller 400 Server Version Configuration Active Compensation click on the link to display the active compensation parameters Active Reflector click on the link to display the details of the active reflector Inclination Sensor state Measurement Time Accuracy Level Temperature Pressure Humidity e MPE Maximum Permissible Error Used in Measurements e Sketch Side View e Sketch Top View e Measurement
43. 64bit 40 24 exactly 5 chars Key WPA2 PSK Passphrase 8 63 chars Key On activating the settings the current connection will be closed and you have to reconnect Apply Required settings Activate WLAN Enabled Ticked SSID User selectable SSID Default Leica AT401 Network Mode Static IP Address IP Address IP address within the allocated range of the network IP Mask Required IP mask i e 255 255 255 0 Gateway Address IP Address of the access point provided by the parent network Please contact your network administrator for detailed information of the required IP address settings Three different encryption modes can be selected e None e WEP 64bit 40 24 Absolute Tracker AT401 Network Settings Network Settings e WPA2 PSK Passphrase The following controls are available WEP Wired Equivalent Privacy using 64 key WEP 40 requires a WEP 64bit 40 74 exactly 5 chars Key key length of exactly 5 characters WPA PSK Passphrase 8 63 chars Key Io Wi Fi Protected Access 2 Pre shared key mode Passphrase allows a key length of 8 to 63 char acters The encryption key can either be entered manually in case the WLAN access point has been configured in advance or automatically generated using the Generate button Generate This key is required to configure the WLAN access point to communicate with the AT Controller 400 Please contact your network administrator for
44. Eek ewa Geosystems The following controls are available User Interface Absolute Tracker AT401 27 item Gemen ooo RRR 1 ein Displays the currently active reflector RRR15 S N 3241 O14 IST TBR 0 5in Click onto areflector element to activate this reflector The state change will be applied instantly and Tracker ae ie Pilot returns to the main page 1oom8 Eet Moving the mouse over a reflector element displays Vew the View icon Click on the icon to display the details of the selected reflector TBROS Name BRR Lin Displays the details about the selected reflector oe Soke Name max 32 characters em SE User definable comment max 128 characters Reflector radius ADM Offset Return to the main page of Tracker Pilot without applying any changes 3 7 2 Reflectors on Advanced User Level General Click on the Status Bar element for Reflector to access the Reflectors Dage RRR 1 5in S N 3316 The reflector page for the user level Advanced looks as follows Tracker Pilot P2P Connection Eek Leica AT401 P2P Connection S N 379978 192 168 0 1 Reflectors q New Tooling Ball Refl 0 5in EI New Red Ring Refl 0 5in is New Red Ring Refl 1 Sin vw New Break Resistant Refl 0 5in dir New Break Resistant Refl 1 5in ve New RFI Reflector 0 5in E New Custom Refl RRR 1 5in BRR 1 5in TBR 0 5in RRRIS BRR15 TBROS S N 3241 aM 3547 The following controls are available 28 Absolut
45. Gigab This connection uses the following items Network Monitor Driver Y T Internet Protocol TCP IP E lt ny Description Transmission Control Protocol Internet Protocol The default wide area network protocol that provides communication across diverse interconnected networks C Show icon in notification area when connected Notify me when this connection has limited or no connectivity Highlight the Internet Protocol TCP IP and click on Properties Point to Point To setup a point to point P2P connection select the radio button Use P2P connection the following IP address Internet Protocol TCP IP Properties General You can get IP settings assigned automatically if your network supports this capability Otherwise you need to ask your network administrator for the appropriate IP settings Obtain an IP address automatically Use the following IP address IP address 192 1668 0 2 Subnet mask 255 255 255 0 Default gateway in DNS serve Use the following DNS server addresses Preferred DNS server Alternate DNS server Enter an IP address in the class C network address range i e 192 168 0 2 for the point to point connection Click into the Subnet mask field below the Subnet address 255 255 255 0 will fill in automatically 58 Absolute Tracker AT401 Network Settings Ce Ens
46. High Speed Inter Connected Shared Connected Network cable unplugged Not connected Disabled Highlight the Local Area Connection or the name of the network card to be used for the connection to the AT Controller 400 Absolute Tracker AT401 73 Network connec tion disruption 74 s Network Connections File Edit View Favorites Tools Advanced Help Back D search f gt Folders z gt b HH Address e Network Connections Type Status Device Name Network Tasks LAN or High Speed Internet E Create a new connection 1394 Connection LAN or High Speed Inter Connected 1394 Net Adapter Gelee Windows Firewall AE LAN or High Speed Inter Disabled Realtek RTL8169 81 10 Fa S Local LAN or High Speed Inter Connected Shared Intel R 82566MM Gigabit Enable this network device e Local LAN or High Speed Inter Disabled Cisco Systems YPN Adapte j Rename this connection iwel Create Shortcut LAN or High Speed Inter Not connected 11a b g n Wireless LAN Mi Change settings of this connection Rename Properties Other Places Details Leica Laser Tracker LAN or High Speed Internet Click the right mouse button to activate the context menu and select Enable to activate the network adapter A disruption in the network connection between the application computer and the AT Controller 400 will be detected by the Tracker Pilot The following message will be displayed in this case Wai
47. LAN or High Speed Inter Connected 1394 Net A g o e Leica Laser Tracker LAN or High Speed Inter Network cable unplugged Realtek R WW Disable this network device Pete R A i wireless Network Connection 2 LAN or High Speed Inter Not connected lia b g n p ete aaa Local Area Connection 2 LAN or High Speed Inter Disabled Cisco Syst A Change settings of this connection Other Places Details Leica Laser Tracker LAN or High Speed Internet Network cable unplugged Highlight the Local Area Connection or the name of the network card to be used for the connection to the AT Controller 400 Network Settings Absolute Tracker AT401 57 55 Network Connections Name Type 2twork Tasks LAN or High Speed Internet L d Create a new connection es Local Area Connection LAN or High Speed Inter pobre Windows Firewall ak 1394 Connection LAN or High Speed Inter settings d Disable this network device LAN or High Speed Inter LAN or High Speed Inter LAN or High Speed Inter Disable MP Wireless D Rename this connection Local Ar Kl Change settings of this connection i Bridge Connections Create Shortcut her Places Rename ptails 2ica Laser Tracker AN or High Speed Internet Click the right mouse button to activate the context menu and select Properties 4 Leica Laser Tracker Properties a General Advanced Connect using ag Realtek ATL8169 8110 Family
48. LB Phone 44 1908 246 294 Fax 44 1908 200 637 Spain Hexagon Metrology S A Parc Tecnologic del Valles C Sabaters 5 ES 08290 Cerdanyola del Vall s Barcelona Phone 34 93 594 69 20 Fax 34 93 594 69 21 USA Hexagon Metrology Precision Center 7 Orchard Road Suite 102 Lake Forest CA 92630 Toll free 1 800 955 5200 Phone 1 949 916 4490 Fax 1 949 916 449 USA Hexagon Metrology Precision Center 2473 Belvo Road Miamisburg OH 45342 Phone 1 937 353 1206 Fax 1 937 247 0426 Absolute Tracker AT401 143 Index A D ADDPEVIATIOMS opteusicticit Mee 142 Default Passwords ccccccceeeeeeeeeseeeeeees 18 Absolute Tracker cvanascecdctveseiomatasideenadontcetsss 6 Description of the system 6 AT Controller EE 6 ME HEEN 6 Available EE aA r 3 RE SE ENEE 127 Create Support File ceeeeeeeeeeees 128 C Support Center essssssnniisssserrrirrrenenn 127 CHECK aa ecsves ease UsiauciGtee te bewaavonmine 75 eebe 88 EEN Detail Report oiii 86 93 Initialization EE 51 dE 77 Installation EES eeeht rees 75 Windows ee V NAWIZ ATION oae 79 Windows EE 8 PDF ReEpOr EECH 87 95 Windows EE 8 PreregU S tES eeccecsccsecssecsessecseessecseesseeee 75 Jaeger Le Mia TE 2 SKEEME Geess 76 M TOOLTIP EE II Meaettrement Time aaa a a 38 TWO FACE sieo ieda ee ad 82 CompensatioM ee 32 96 N EE Geet 34 36 Navigation ADM Compensation 0ccceeeeeeeeees 111 ein ee E 32 Angle Compensation
49. Parameters New Active Deviation U S5 Incl Ind L deg 0 0017 0 0011 0 0006 0 0000 Incl Ind C deg 0 0031 0 0052 0 0021 0 0000 Inclination Sensor On Om c deg 0 0062 0 0061 0 0000 0 0001 i deg 0 0037 0 0037 0 0001 0 0002 j deg 0 0035 0 0030 0 0005 0 0001 Corrected Measurements Id H deg V deg D mm H Dev deg V Dev deg D Dev mm 1 124 7941 133 4050 2049 901 0 0000 2 125 5379 119 8224 2820 906 0 0000 3 122 4963 108 3549 4435 908 0 0000 4 129 0941 89 1018 2101 568 0 0002 5 120 9329 89 2537 2934 852 0 0002 6 122 7979 89 4434 4594 897 0 0001 Measurements Sketch 0 0001 0 001 IP Address Tracker Serial Accuracy Level Pressure 192 168 0 1 390413 S D 3 976 mBar Id H deg V deg D mm H Dev deg V Dev deg D Dev mm 1 235 1932 133 3705 2123 120 2 234 4526 119 7985 2894 127 3 237 4959 108 3410 4509 130 4 230 8992 89 0685 2174 790 5 239 0608 89 2310 3008 075 6 237 1958 89 4301 4668 120 0 0093 0 0082 0 0075 0 0065 0 0065 0 0062 Absolute Tracker AT401 0 0344 0 0241 0 0139 0 0333 0 0228 0 0132 0 010 0 010 0 016 0 020 0 009 0 015 The following actions can be taken 109 110 Save the Report as PDF file This button can be used to save the PDF Report in a personal folder In this case no copy of the report will be saved into the default location Ca Print the Report CHE P Use the Back button to navigate back
50. T401 59 GF Control Panel X Search Control Panel 2 Adjust your computer s settings View by Category Wi System and Security User Accounts and Family Review your computer s status Safety Back up your computer Add or remove user accounts Find and fix problems Se Set up parental controls for any user Gi Network and Internet Appearance and s Connect to the Internet e p lizati View network status and tasks EE Choose homegroup and sharing options Change the theme Change desktop background Hardware and Sound Adjust screen resolution View devices and printers e Adda device Clock Language and Region Change keyboards or other input Programs senge Change display language Uninstall a program Ease of Access Let Windows suggest settings Optimize visual display ESE gt Control Panel Network and Internet gt e Search Control Panel 2 Control Panel Home View network status and tasks Connect to a network View network computers and devices Add a wireless device to the network System and Security Network and Internet Hardware and Sound Programs User Accounts and Family Internet Options Safety Connect to the Internet Change your homepage Manage browser add ons Delete browsing history and cookies HomeGroup Choose homegroup and sharing options Appearance and Personalization Clock Language and Region Ease of Access Network and Sharing Center Click on the Netwo
51. Tracker ioti Suppa i ell sl P ES Mew Proba Tock Hep Sr Abest h O Cionon and Setting OPES 106 application Cesta Fe mech Pict Sa geet r Ej F D Zar At gg he 2050 LEO Beete LED REPU Toes Pe CL oe Baten PSS Bae SS 0 EREM eer EE COMPEREATIONS e GG 2010 I 7 1 5 Import of Compensations amp Reflectors General L Prerequisites Previously exported compensations and reflectors can be imported into the Absolute Tracker AT401 again This function is only available to Advanced user level The amount of compensations and reflectors that can be stored on the Absolute Tracker AT401 is limited Item Maximum number of records on Absolute Tracker AT401 Reflectors 25 Compensation records can only be imported to the instrument where the records have been created originally It is not possible to upload a compensation record to a different instrument Absolute Tracker AT401 135 Help File name amp loca tion Procedure Import Reflectors 136 Standard reflector types can be shared between different Absolute Tracker AT4O1 Le to have common reflector definitions on all sensors Custom reflector types with an individual ADM Offset compensation can only be imported to the instrument where the records have been created originally It is not possible to upload a custom reflector to a different instrument Previously exported compensations and reflectors are stored into two Separate files Compensa AT40
52. Windows Vista C Users Local User AppData Roaming Tracker Pilot Reports Windows 7 C Users Local User AppData Roaming Tracker Pilot Reports Refer to Viewing PDF Reports on page 50 for details on viewing saved Check reports Absolute Tracker AT401 95 6 Compensation General Measurement precision Space requirement Best practice 96 Leica Geosystems products are manufactured assembled and adjusted to the best possible quality Quick temperature changes frequent move ment of the product shock or stress can cause deviations an decrease of the measurement accuracy It is therefore recommended to check the product in regular intervals This can be done onsite by running through specific check or compensa tion measurements If checks do not provide satisfying results repeatedly a compensation of the product is recommended To achieve precise measurement results in the daily work it is important to check and adjust the product from time to time During the manufac turing process the product parameters are carefully determined As mentioned above the values can change an it is highly recommended to check or adjust the product in the following situations e Before the first use of the product e Before taking high precision measurements e After long transportations e After long working periods e After long storage periods e Ina high or low temperature environment Before starting to work the
53. access point to communicate with the AT Controller 400 Please contact your network administrator for detailed information of the required WLAN encryption settings Changing the IP settings and encryption mode will be stored persistently After a restart of the Absolute Tracker system the WLAN parameter settings will remain Ensure all setting are entered correctly and click Apply to activate the network connection The LCD display of the AT Controller 400 displays a message while the system is being reconfigured The Tracker Pilot will return to the Select Sensor page The IP Address will be displayed on the LCD screen of the AT Controller 400 Le Not encrypted i fl PE AE dl or 21 33 101 22 lt 0 0 0 0 Gee AE dl orn 2 1 33 1 01 22 0 0 0 0 Encrypted A new connection needs to be created using the IP address displayed on the LCD screen of the AT Controller 400 Refer to New Connection on page 19 for details on creating a new connection Absolute Tracker AT401 69 4 3 5 General IP config 70 Troubleshooting Network Problems Network communication problems can have various reasons Therefore it is recommended to verify all items shown below in case of network communication problems Click on the button to open the Windows Start menu OPERATOR Internet My Documents e Internet Explorer UY N 4 My Recent Documents gt Gid E mail LA y Lotus Notes v3 My Comput
54. al Number of connected Absolute Tracker The Data Read Out window DRO displays the following elements a Current reflector position a p lt lt ek we b Last measured point Face I I c Face i H 111 1906 111 1907 deg 4 S SE a e Selected length uni 7 87 5251 f Expanded Uncertainty Ugs geg 3349 501 3349 501 mm e k 2 of the last measured f U 95 0 004 mm point g Distance h Vertical angle i Horizontal angle The DRO window shows the following status information Absolute Tracker AT401 User Interface Ready reflector locked and ready to measure 111 1906 111 1908 deg 87 5250 87 5252 d eg 3349 501 3349 507 mm 0 00310 mm Measurement in progress Not ready no reflector locked or not ready to measure K Move the mouse over the Measurement button to display a tool tip providing information about the current state Tracker controls The following Tracker controls are available Description Initialize the Absolute Tracker AT401 An initialization must be executed after the first start or a restart of the Absolute Tracker system After a significant temperature change or after moving the Tracker the user might be asked to initialize the Absolute Tracker Cs A reflector needs to be in the field of view for the initialization process Find Reflector F6 within the field of view of the ATR Find Reflector using the Overview Camera OVC F11 Start Measure
55. and Faxes 2 Heln and Siinnart Launch the Control Panel E Control Panel File Edit View Favorites Tools Help Q Back a ES Search iE Folders Ez DER Address Control Panel See Also Bluetooth Konfiguration Date and Time g Windows Update Help and Support a oa r Ze Game Controllers Internet Options a NVIDIA nview Desktop Manager Display Folder Options is amp Java Keyboard a b NVIDIA Phone and Modem Power Options Systemsteuerung Options a 3 Printers and Faxes QuickTime Regional and Language Scanners and Cameras Scheduled Tasks Options Double click on the Network Connections icon K Network Connections File Edit View Favorites Tools Advanced Help Q sxx bi JO search 1 Folders E DS Address e Network Connections Name Network Tasks LAN or High Speed Internet E Create a new connection e amp sLocal Area Connection Change Windows Firewall lt A 1394 Connection settings Wi Disable this network device si Rename this connection E Change settings of this connection Leica Laser Tracker LP Wireless Network Connection 2 Local Area Connection 2 Other Places Details Leica Laser Tracker LAN or High Speed Internet Network cable unplugged Realtek RTL8169 8110 Family Gigabit Ethernet NIC Type LAN or High Speed Inter LAN or High Speed Inter LAN or High Speed Inter LAN or High Speed Inter LAN or
56. axis Offset Oy e Collimation Buckling H e Collimation Buckling H Exponent e Collimation Buckling V e Collimation Buckling V Exponent Compensation Date ADM Offset e Compensation Date e H Offset horizontal e V Offset vertical Measurement Time The measurement time for basic measurements checks and compensa tions is user selectable Measurement Default Mode Basic main gt 500 ms lt 25000 ms 2000 ms page Check gt 500 ms lt 25000 ms 2000 ms Absolute Tracker AT401 User Interface L L Setting measure Measurement Time Measurement Default Mode Compensation gt 2000 ms lt 25000 ms 5000 ms For high precision measurement a measurement time of gt 2000 ms is strongly recommended For check and compensation measurements a measurement time of 5000 ms is recommended To change the current measurement time click into the Measurement ment time Time input field and enter the desired measurement time in the given units Hit Enter to apply the change Measure Time 5000 ms To reset the measurement time to the default value of 2000 ms click the Default button which appears when changing the measurement time Measure Time 8000 bel Gescht 3 10 Configuration General The configuration menu provides access to general system and software settings and status information To access the system settings click on Configuration Settings in the menu Dar Configuration
57. bed in the About Box The following controls are available Installation Absolute Tracker AT401 11 Tracker Pilot Starts the installation of Tracker Pilot Opens this reference manual Manual ne Opens a file explorer to display the content of the Product CD Sa Exits the application Tracker Pilot instal Click on the button Tracker Pitot to start the installation lation Welcome to the Tracker Pilot Setup Wizard This will install Tracker Pilot on your computer it is recommended that you close all other applications before continuing Click Next to continue or Cancel to exit Setup Select Destination Location Where should Tracker Pilot be installed D Setup will install Tracker Pilot into the following folder To continue click Next If you would like to select a different folder click Browse C Users Tester Desktop At least 52 8 MB of free disk space is required To select a different installation folder press and choose the location where the Tracker Pilot shall be installed Ce It is recommended to install the Tracker Pilot into the proposed folder Click to continue 12 Absolute Tracker AT401 Installation Select Start Menu Folder Where should Setup place the program s shortcuts A Setup will create the program s shortcuts in the following Start Menu folder To continue click Next f you would like to select a different folder click Browse Leica Tracker Pilot
58. ck on the Finish button to generate the PDF report and _ finish the ADM Compensation process Click on the Cancel button to cancel the wizard and delete all measurements lt Back Ce Cancelling the process deletes all measured data 124 Absolute Tracker AT401 Compensation Category Detail Information Information Passed Failed Name Comment Configuration User Windows User Login amp Tracker Pilot Login Tracker click on the link for further details IP Address Tracker Type Absolute Tracker AT401 Serial Number AT Controller 400 Server Version Active Compensation click on the link to display the active compensation parameters Active Reflector click on the link to display the details of the active reflector Inclination Sensor state Measurement Time Accuracy Level Temperature Pressure Humidity Parameters New ADM Reflector Offset Active ADM Reflector Offset Deviation U 95 Measurements Sketch Side View Sketch Top View Measurement Details Table Kee Within the Report page of the Tracker Pilot tool tips are still displayed in sketch view and measurement details can be viewed as well Kee Use the Back button to navigate back to the measurements page i e to delete measurements or take additional measurements on Station 2 In case measurements from Station 1 have to be remeasured the whole station has to be repeated When returning to the Report page the report will be updated dynam
59. d Out DRO window provides numerical information about the current approximate position and the deviation to the target position Position deviations over the tolerance will be flagged with red background color The Data Read Out DRO window shows the following status informa tion Check Absolute Tracker AT401 77 Not ready no reflector locked or not ready to measure Ce Move the mouse over the Measurement button to display a tooltip providing information about the current state Ready reflector locked and ready to measure Measurement in progress Individual tolerance exceeded 87 5501 8 3395 903 33 DRO Display modes The Data Read Out DRO offers two different modes in check wizards to display the current reflector position Displays the absolute values of e Horizontal Angle H e Vertical Angle V e Distance D of the current reflector position in the sensor coordinate system Displays the relative values of e Horizontal Angle Delta AH e Vertical Angle Delta AV e Distance Delta AD of the current reflector position in relation to the next point to measure H KN d Click on to toggle between the DRO display modes 78 Absolute Tracker AT401 Check The following symbols provide a graphical guidance in Delta HVD mode to find the nominal position E Move the reflector up wm Move the reflector down via Move the reflector towards the Absolute Tracker AT401 Move th
60. e PDF Report will be generated A message is displayed during this process Measurements All measurements taken are listed in the Measurements table on the table bottom half of the screen Check Absolute Tracker AT401 91 Result 92 Measurements Id H deg V deg D mm Std Dev mm Delete i In 0 1877 89 3147 1967 900 0 174455 2 In 178 8947 90 6574 2022 530 0 51350 1 Station 1 ADM Measurements In Measurements Id H deg V deg D mm Std Dew mm Delete 1 Out 0 8463 89 8153 1994 336 0 96833 E 2 Qut 0 2611 89 6834 5996 920 0 70718 E 2 Station 2 ADM Measurements Out The following actions can be taken Description Click on the point ID to open a pop up window showing details about the selected measurement record Click on the trash bin icon to delete a single measurement record Pv oon Move the mouse over indiviual measurement values to e ep display a tooltip with the measurement value and tolerance 2 SC used where applicable Reeg Navigate back to Station 1 to optionally analyze measure _ ment details in the Measurements table ee Navigate forward to Station 2 to optionally analyze meas _ urement details in the Measurements table The Report page summarizes the results of the ADM Check The ADM Check is passed within tolerance The ADM Check failed tolerance has been exceeded or measurement setup is insufficient In cas
61. e Tracker AT401 User Interface RRR 1 5in RRR15 S N 3241 TBR 0 5in TBROS Tooling Ball Loo UG psy e View Name BRR 1 5in Comment S N 6658 Reflector Radius 19 050 mm ADM Offset 0 000 mm BRR 1 5in BRR15 S N 6658 2 v 2029 delete p view ER New Tooling Ball Refl 0 5in op New Red Ring Refl 0 5in ER New Red Ring Refl 1 Sim EI New Break Resistant Refl 1 5i1 EI New Break Resistant Refl 0 Sit Displays the currently active reflector Click onto a reflector element to activate this reflector The state change will be applied instantly and Tracker Pilot returns to the main page Moving the mouse over a reflector element displays the View icon Click on the icon to display the details of the selected reflector Displays the details about the selected reflector Name max 32 characters User definable comment max 128 characters Reflector radius ADM Offset Click on Delete to remove a reflector permanently from the Absolute Tracker AT401 Click on New Tooling Ball Refl 0 5in to create a new 0 5 TBR reflector Refer to Create new standard reflector on page 30 for details on creating new reflectors Click on New Red Ring Refl 0 5in to create a new 0 5 RRR reflector Refer to Create new standard reflector on page 30 for details on creating new reflectors Click on New Red Ring Refl 1 5in to create a new 1 5 RRR reflector Refer to Create new standard reflecto
62. e on the bottom half of the screen Measurements Id H deg V deg D mm 5td Dev mm H Dev deg V Dev deg D Dev mm Delete 1 272 9861 90 2058 2080 567 0 00171 0 007135 0 021851 0 03792 H 2 272 8549 90 1961 20184 202 0 00271 0 007278 0 021072 0 03985 E a 272 7616 90 1894 40323 686 0 002360 0 007331 0 020038 0 03766 E 4 274 8662 125 0389 2286 350 0 00421 0 009224 0 022343 0 03210 E The following actions can be taken Click on the point ID to open a pop up window showing details about the selected measurement record ao Click on the trash bin icon to delete a single measurement record ES e Move the mouse over indiviual measurement values to display a tooltip with the measurement value and tolerance es used where applicable 57 02 The Report page summarizes the results of the Two Face Check Description The Two Face Check is passed within tolerance rn The Two Face Check failed tolerance has been exceeded In case a Two Face check fails it is recommended to perform an Angle Compensation Refer to Angle Compensation on page 104 for details on the Angle Compensation Absolute Tracker AT401 85 Report 86 f Passed Name Comment Configuration User Tracker IP Address Tracker Type Tracker Serial Server Version Compensation Reflector Inclination Sensor Measurement Time Accuracy Level Temperature Pressure Humidity Results
63. e reflector away from the Absolute Tracker AT401 Move the reflector clockwise with reference to the sensor gt gt unit position for ADM Check only Move the reflector counter clockwise with reference to the lt sensor unit position for ADM Check only Navigation The following controls are available in all check wizards Check Absolute Tracker AT401 79 Settings 80 Find Reflector F6 Ba Find Reflector with OVC F11 Measure F2 Toggle DRO between HVD and Delta HVD Display Toggle DRO to HVD display Toggle between full sketch view full DRO view and shared view F12 net gt Navigate to next wizard page F9 a Navigate to previous wizard page F10 TS Cancel the process and discard all measurements Cancel pr Delete a single measurement View measurement details The following controls are available in all check wizards to display settings or measurement parameters The settings cannot be changed inside the check wizard Absolute Tracker AT401 Check dn 20 0 C 1013 mBar 20 4 RRR 1 5in S N 3316 2010 04 29 15 37 Angle 18 4 C RRR 1 5i1 Measure Time 5000 ms Selection navigation bar Check Two Face ADM Check Displays the inclination sensor state Refer to Inclination on page 41 for details on the inclination sensor Displays the source and actual values of the environmental parameters Refer to Meteo Monitor on page
64. e state of the inclination sensor will be changed when a compensation state record is activated according to the inclination sensor state retained in the compensation record S Independently from the inclination sensor state marked in the compen sation record the actual setting of the inclination sensor can manually be overwritten i e the inclination can be set to disabled when using a compensation record marked with inclination sensor on Refer to Inclination on page 41 for further details on setting the incli nation sensor state 6 1 2 Angle Compensation General The Angle Compensation routine verifies the system geometry horizontal and vertical collimation Large ambient temperature changes may require to perform an Angle Compensation Compensation Angle Compensation measurements consist of the following 2 step procedure process 1 Measurement of two points at a steep angle at a given distance ideally points at floor level 2 Measurement of four points at a given distance ideally on a line at the height of tilting axis of the Absolute Tracker AT401 104 Absolute Tracker AT401 Compensation Required setup The required setup for the Angle Compensation is shown below e e C Ce The measurements should be taken in sequential order and close to the specified point locations Compensation Absolute Tracker AT401 105 Procedure step by step l Setup the Absolute Tracker system according the setup
65. e the ADM Check fails it is recommended to repeat the check once If the ADM Check fails again an ADM Compensation is recommended Refer to ADM Compensation on page 111 for details on the ADM Compensation Absolute Tracker AT401 Check Report Check The Report shows detailed information about the ADM Check w Passed Name Mar 24 2010 14 31 Comment 16 4 C RRR 1 5in Configuration User OPERATOR as Standard Tracker P2P Connection IP Address 192 168 0 1 Tracker Type Leica AT401 Tracker Serial 390206 Server Version 3 6 70 Compensation Mar 24 2010 13 52 Reflector RRR 1 5in Inclination Sensor On Measurement Time 2000 ms Accuracy Level 1 00 Temperature 16 4 C Pressure 968 mBar Humidity 22 Results MPE Used o Parameters 5 263 1836 180 1842 443 0 000 Measurements In In 326 4967 89 0208 3205 456 2 In 137 1845 89 5978 3321 652 Measurements Out 1 Out 128 9211 89 0704 2869 963 2 Out 130 3532 89 9122 9248 344 Absolute Tracker AT401 93 94 The following actions can be taken Save the Report as PDF file This button can be used to save de a copy of the PDF Report in a personal folder Print the Report Ea See Use the Back button to navigate back to the measurements _ page Click on the Finish button to generate the PDF report and _ finish the Two Face Check process
66. easure Point 1 Out Move the reflector to Point 2 Out The DRO window and the sketch provide guid ance to find the correct position 18 Press the Measure F2 button to measure Point 2 Out gt 19 Optionally analyze measurement details in the Measurements table delete or repeat measurements accordingly 20 Navigate to the Report page when all measurements are taken 21 The ADM Compensation is marked as Passed or Failed depending on the measurement results Click on the Show Report icon to view detailed results of the ADM Compensation 22 Finish the ADM Compensation process The compensation parameters will be stored on the system and the PDF Report will be generated A message is displayed during this process Measurements All measurements taken are listed in the Measurements table on the table bottom half of the screen 114 Absolute Tracker AT401 Compensation Measurements Id H deg V deg D mm Std Dev mm Delete i In 0 1877 89 3147 1967 900 0 14455 2 In 178 8947 90 6574 2022 530 0 51350 l Station 1 ADM Measurements In Measurements Id H deg V deg D mm Std Dew mm Delete 1 Out 0 8463 89 8153 1994 336 0 96833 E 2 Qut 0 2611 89 6834 5996 920 0 70718 E 2 Station 2 ADM Measurements Out The following actions can be taken Description Click on the point ID to open a pop up window showing details about the selected measurement record
67. emoved from the sensor Ce The Tracker Pilot does not allow to import a compensation with the same name as an existing compensation on the system The screen shows a preview of the changes Help Absolute Tracker AT401 139 Troubleshooting 140 Tracker Pilot P2P Connection Leica AT401 P2P Connection S N 390406 192 168 0 1 Support Center Import Compensations H Total 3 of maximum 25 items z 2010 04 29 15 37 2010 04 29 15 37 gt 2010 04 29 15 37 S 2010 04 29 15 37 Angle 18 4 C RRR 1 5in Angle 4 C RRR 1 5ir Ka 2010 04 29 15 53 Import 2010 04 29 15 53 2 2010 04 29 15 54 2010 04 29 15 54 ADM 18 4 C RRR 1 5in ADM 18 4 C RRR 1 5in yo 2010 04 29 16 06 Import 2010 04 29 16 06 gt 2010 04 29 16 06 spin OF 18 DE ADM 18 4 C RRR 1 5in 7 ADM 18 4 C RRR 1 5in The following controls are available con Description Import selected reflectors to the Absolute Tracker AT401 Ce Changes will only be applied when clicking on the button Import Cancel and leave the import dialogue without committing ei any changes Click on the button Import to apply the changes on the Absolute Tracker AT401 The following screens shows the progress of the import Updating data The Tracker Pilot returns to the Support Center page after the import has finished When the maximum number of compensations or reflectors is already stored on the Absolute Tracker AT401 no m
68. ensation process Move the reflector to Point 1 In The DRO window and the sketch provide guidance to find the correct position 13 Press the Measure F2 button to measure Point 1 In Repeat steps 9 amp 10 for Point 2 In RW Optionally analyze measurement details in the Measurements table delete or repeat measurements accordingly Absolute Tracker AT401 Compensation 16 Move the Absolute Tracker AT401 to Station 2 ADM Offset Compensation Measurements Out the reflector remains on the same point Navigate to the ADM Offset Compensation Measurements Out page Point the laser beam to the vicinity of Point amp 1 Out and click on Find Reflector F6 e A message is displayed during the find process 17 18 19 1 3 4 5 Press the Measure F2 button to measure Point 1 Out gt 20 Move the reflector to Point 2 Out The DRO window and the sketch provide guid ance to find the correct position 2 Press the Measure F2 button to measure Point 2 Out 22 Optionally analyze measurement details in the Measurements table delete or repeat measurements accordingly 2 Navigate to the Report page when all measurements are taken 2 The ADM Offset Compensation is marked as Passed or Failed depending on the measurement results Click on the Show Report icon to view detailed results of the ADM Compensation during this process 2 Finish the ADM Offset Compensati
69. er e Notepad a My Network Places ES Microsoft Office Excel 2003 amp Control Panel GN Set Program Access and f i Adobe Acrobat 7 0 Defaults Professional uA t Connect To b DI iPassConnect LGS Va Printers and Faxes Snaglt 7 Help and Support 1 So Search Log Off Shut Down Select Run this will open the following dialog box All Programs gt Type the name of a program folder document or Internet resource and Windows will open it for you x Type cmd for command prompt and dck ok JL The following window appears cx C WINDOWS system32 cmd exe fxi iC gt ipconf ig Type in ipconfig and hit Enter The following page will be displayed Absolute Tracker AT401 Network Settings Ping command Network Settings ex C WINDOWS system32 cmd exe C gt ipconfig Windows IP Configuration Ethernet adapter Leica Laser Tracker Connection specific DNS Suffix IP Address Z i 492 168 0 3 255 255 255 0 as Default Gateway Ethernet adapter Wireless Network Connection 2 Media State Media disconnected gt ae The IP addresses of all network adapters are displayed Identify the network adapter used for the connection to the AT Controller 400 and verify the settings are correct Once the network settings on the application computer are verified the communication to the AT Controller 400 can be tested using the ping command Click
70. er 400 gt EI Network and Internet Network Connections gt X Organize v Disable this network device Diagnose this connection Ms Local Area Connection Net x ae Bro EK Disable Status Diagnose Bridge Connections Create Shortcut Delete Rename Properties Click the right mouse button to activate the context menu and select Properties Depending on the Windows security settings the following dialog may pop up User Account Control e Do you want to allow the following program to make P changes to this computer SS Program name Network Connections Verified publisher Microsoft Windows File origin Hard disk on this computer To continue type an administrator password and then click Yes Igel Admin Eat v Show details Help me decide In this case an Administrator is required to change the network adapter settings Please contact your system administrator Absolute Tracker AT401 61 Point to Point P2P connection Network connec tion DHCP 62 f Local Area Connection Properties x Ir Networking Connect using Sr Broadcom NetXtreme Gigabit Ethemet This connection uses the following items oM Client for Microsoft Networks Z QoS Packet Scheduler A File and Printer Sharing for Microsoft Networks Intemet Protocol Version 6 TCP IPv6 4 Intemet Protocol Version 4 TCP IPv4 Link Layer Topology Discovery Mapper 1 0 Driver
71. erature sensor can lead to erroneous measurements of 4 5 ppm Ce Setting the Meteo Monitor to manual input of the environmental values will not be stored persistently By default automatic readings of the envi ronmental data will be enabled at startup of the Absolute Tracker Network Settings Click on Network Settings to access the network settings page User Interface Absolute Tracker AT401 43 la LAN Configuration Network Mode IP Address 192 168 0 fe Get Address from DHCP 355 o IP Mask 255 255 255 0 S Static IP Address Gateway Address D 0 1 1 On activating the settings the actual connection will be closed and you have to reconnect Apply W LAN Configuration Activate WLAN SSID Network Mode On activating the settings the actual connection will be closed and you have to reconnect Apply The following types of connections are available Network Connection Type LAN Connection WLAN Connection Get Address from DHCP Get Address from DHCP Static IP Address Static IP Address Refer to Tracker Pilot Network Settings on page 63 for detailed instruc tions on setting up different types of network connections to the AT Controller 400 Ce For certain countries with special regulations for operating wireless networks the WLAN module will be decommissioned by the factory The user of the product will not be able to activate the WLAN module in this case Please contact
72. h Tracker Pilot double click onto the desktop shortcut Tracker Pilot Alternatively the software can be started from the Windows Start menu Click on the button to open the Windows Start menu Navi gate to the menu entry Leica Tracker Pilot A submenu pops up click on the item Tracker Pilot to launch the software Bluetooth Umgebung OPERATOR Py IT Support UE Set Program Access and Defaults Ki Internet Accessories Internet Explorer e i g fam Leica Tracker Pilot gt GR tracker Pilot Gif Lotus Notes EH Metrolog XG gt Si Uninstall TrackerPilot I QuickTime D fa Notepad Real ei GyroTools GO Professional Edition 1 0 gt B Microsoft Office Excel LEICA Geo Office Tools ICH Leica Geosystems gt KK Adobe Acrobat 7 0 a Professional I snagit 7 gt ei Desktop Restore D Snaglt 7 P Startup W Paint ei SwapFTL LU ei TargetProcess LU ra iPassConnect LGS ei TextTool gt ei Think antage D e All Programs E TP51100 ei Leica System 1200 gt ei T Scan Inspect 3 01 D g Start E o ei TwixTel D Tracker Pilot launches with Standard user level by default To change the user level click on the user icon at the bottom left hand corner of the status bar on the main page ed E A The user selection page allows to log in with a different user level The current user level is displayed on the top right hand side of Tracker Pilot e ll xj Leica AT401 P2P
73. his update will take approximately 00h 02m Install now o To start the system update click on Install now o To cancel the update click on Back Depending on the system software components contained in the update package the update can take a significant amount of time up to 2 hours Once the update process is running it must not be stopped To avoid an unintended interruption the Windows control to close the Tracker Pilot is disabled Absolute Tracker AT401 131 Ce The application computer needs to be connected to the AT Controller 400 during the entire update process as the system parameters compensa tions reflectors and persistent system settings will be backed up and restored during the update process The system update will now start A progress bar informs about the prog ress of the update and the remaining time gt Install Update 2 Installed Version 1 1 5517 0 Update Version 1 1 5705 0 aea Oih 22m 57s remaining In case the Update package contains a new version of the Tracker Pilot itself the software will shutdown for the update The following message will be displayed while the Tracker Pilot is updated Updating TrackerPilot please wait Once the system update has finished the system prompts that the updates have been installed successfully 132 Absolute Tracker AT401 Help Troubleshooting eer Install Update Installed Version 1 1 5361 0 Update Version 1
74. hown e Compensation name consisting of the date amp time the compensation has been finished Start time of the compensation Type of compensation Environmental parameters Active reflector s Angle 20 1 el RRR 1 5in T KT Click onto a compensation element to activate this 2010 04 15 09 12 o compensation record The state change will be applied vey instantly and Tracker Pilot returns to the main page CS gt Activating a compensation requires to re initialize the Absolute Tracker Moving the mouse over a compensation element displays the View icon Click on the icon to display the details of the selected compensation record Displays the details about the selected compensation record e Compensation date e Name max 32 characters e User defined comment max 128 characters e Reflector type O Bak Return to the main page of Tracker Pilot without applying any changes NEBE A message is displayed while the data on the Absolute ier AT4O1 is updated On Standard user level a condensed summary of the compensation details will be displayed Compensation Date 2010 04 11 23 13 Name 2010 04 11 21 13 Comment Axes 24 8 C RRR 1 5in Reflector Type Unknown Compensation Compensation Date Name Comment Reflector Type Absolute Tracker AT401 User Interface 3 8 2 Compensations on Advanced User Level General User Interface Click on the Status Bar element for Compe
75. ically PDF report The generated PDF report is saved in the following default location on the application computer unless its saved into a personal folder manually Windows XP C Documents and Settings Local User Applica tion Data Tracker Pilot Reports Compensation Absolute Tracker AT401 125 Windows Vista C Users Local User AppData Roaming Tracker Pilot Reports Windows 7 C Users Local User AppData Roaming Tracker Pilot Reports Refer to Viewing PDF Reports on page 50 for details on viewing saved Compensation reports 126 Absolute Tracker AT401 Compensation 7 Help General The Help section provides the following functionality e System Maintenance functions e User Manual e Software version and copyright information 7 1 Support Center General The Support Center provides functionality to maintain the Absolute Tracker system Modules The following modules can be selected Help Open Leica Support Website Export Compensations amp Reflectors Loch Import Compensations amp Reflectors ig Absolute Tracker AT401 127 7 1 1 Create Support File General L Creating Support File File location 128 The Support File provides important information to Leica Geosystems support staff for troubleshooting In case of doubt or problems with the Absolute Tracker system a Support File should be generated and sent to your Leica Geosystems representative Whenever support from Leica Geosystems
76. ilable in all compensation wizards Compensation Absolute Tracker AT401 101 Settings 102 Find Reflector F6 Da Find Reflector with OVC F11 Measure F2 Toggle DRO to Delta HVD display Toggle DRO to HVD display Toggle between full sketch view full DRO view and shared view F12 net gt Navigate to next wizard page F9 e Navigate to previous wizard page F10 TS Cancel the process and discard all measurements Cancel pr Delete a single measurement View measurement details The following controls are available in all compensation wizards to display settings or measurement parameters The settings cannot be changed inside the compensation wizard dh 20 0 C 1013 mBar 20 Description Displays the inclination sensor state Refer to Inclination on page 41 for details on the inclination sensor Displays the In Outdoor mode Ce Compensations can only be done in Indoor mode Refer to In Outdoor Mode on page 40 for details on the In Outdoor mode Displays the source and actual values of the environmental parameters Refer to Meteo Monitor on page 42 for details on the meteo parameters Absolute Tracker AT401 Compensation RRR 1 5in Displays the active reflector SIN 3316 Refer to Reflectors on page 27 tor details on reflectors 2010 04 20 15 37 Displays the active compensation T Angle 18 4 C RRR 1 5 Refer to Compensations on page 3
77. ilot I QuickTime gt fa Notepad Real e i ei GyroTools GO Professional Edition 1 0 gt Microsoft Office Excel H LEICA Geo Office Tools gt FL Adobe Acrobat 7 0 Ki Leica Geosystems Professional ei snagit 7 gt Snagit 7 vi Desktop Restore b Ir Startup gt CO Paint CH SwapFTL gt ei TargetProcess gt r iPassConnect LGS Le TextTool D E Thinkvantage gt All Programs EE b Ir Leica System 1200 gt Lol T Scan Inspect 3 01 gt d en TwixTel gt Navigate to the menu entry Leica Tracker Pilot A submenu pops up containing an item Uninstall Click on the item Uninstall Tracker Pilot to remove the Tracker Pilot Tracker Pilot Uninstall K re you sure you want to completely remove Tracker Pilot and all of its components Click if you want to continue to remove Tracker Pilot from the application computer Click to cancel the uninstall 14 Absolute Tracker AT401 Installation 2 4 General Installation Tracker Pilot Uninstall Uninstall Status G Please wait while Tracker Pilot rs removed from your comptes Uninstalling Tracker Pilot The progress bar displays the status of the uninstall progress Tracker Pilot Uninstall e 1 Tracker Pilot was successfully removed from your computer A message is displayed to confirm that Tracker Pilot has been uninstalled successfully Close this message by clicking __ok LL Absolute Tracker System Software The system software of the Absolute Tracker is
78. is required please generate and send a Support File via e mail to your local support representative To create a Support File click on the icon The Support File generated contains W Crate Sunnast Hie the following information e Actual state of the system e Error logs e Debug information Create a file that helps to identify user problerns The Support File will be stored in the following location Windows XP C Documents and Settings Local User Applica tion Data Tracker Pilot Support Windows Vista C Users Local User AppData Roaming Tracker Pilot Support Windows 7 C Users Local User AppData Roaming Tracker Pilot Support Once the Support File has been saved a Windows Explorer will open up showing the content of the folder specified above Absolute Tracker AT401 Help 7 1 2 Open Leica Support Website General The Leica Geosystems Support Website provides information to find a contact person of your local Leica Geosystems representative Contact person click on the following icon Find a contact person in your region CL Open Leica Support Website for e Sales e Support e Technical Service Open Leica Geosystems support website Regional contacts Clicking on the icon opens the following website in the default web browser of the application computer Solutions Products Customer Services Support Customers Press Aboutus Contact Downloads Contact Metrology gt C
79. ization General Procedure User Interface Under certain circumstances an initialization may be required or recom mended Absolute Tracker system state Initialization Startup of the system Active compensation changed Absolute Tracker system moved Inclination sensor enabled An impediment message will be displayed as a tool tip on the Start Measurement F2 button in case an initialization is required or recom mended Item Description eegener 1 Arn initialization is recommended to ensure highest Chk to toer possible accuracy of the Absolute Tracker An initialization is required Refer to Impediments on page 54 for details on Impediment messages The initialization takes approximately 50 to 60 seconds and consists of a number of inclination measurements and a single two face measurement to adjust sensor internal parameters A message is displayed during the initialization process Please wait Please wait initializing A reflector needs to be in the field of view of the Absolute Tracker AT401 for the initialization process Ensure the Absolute Tracker AT401 is accurately levelled before initializing the system The electronic bubble should be as close to the center as possible the L and T values displayed on the Levelling Page of the AT Controller 400 should be between 4 and 4 Absolute Tracker AT401 51 3 12 Find Reflector General The Find Reflector
80. l 0 eeeeeee 21 RE VIDO AUG eebe ees 21 SYSTEM Overview scevas eededtcedseracededveceadiccee 6 T Tracker Pilot ACCESS LOVG gege 16 baten GEN 54 Ni ZO TOM WEE 51 Ka aca e wg e EE 8 Windows EEN 8 Network Settings cccccceseesseeeeeeeeees 63 Prerequisites cccecececceecceeeeeeeeeeneeteeeeaes 6 LPS e UE 15 Update System 130 Warning amp Error Messages n 54 Tracker Programming Interface 066 3 U Update System Software cccccceeceeeeeeeeeeeeeeees 15 Tracker PIOC 25 25 0025 sacs e aeai A 14 W Window User Account Control UAC 7 WLAN Wiele GE 68 EFICHY DUIOM iccasesaesctaniaucverstuhiegnacneeds 66 68 France Regulation ccccceeeeseeeeeeeeees 44 Static IP Address ccccecceeceeeeeeeeseeees 66 Index Absolute Tracker AT401 145 Leica Geosystems AG Metrology Products Moenchmattweg 5 CH 5035 Unterentfelden Switzerland Phone 41 62 737 67 67 info metrology leica geosystems com www leica geosystems com metrology Whether building the fastest car the biggest plane or the most precise tooling you need exact measurements to improve quality and productivity So when it has to be right professionals trust Leica Geosystems Metrology to help collect analyze and present 3 dimensional 3D data for industrial measurement Leica Geosystems Metrology is best known for its broad array of control and industrial measurement products in
81. l Panel To setup a network connection where the network adapter obtains its IP address from DHCP select the radio button Obtain IP address automati cally Absolute Tracker AT401 Network Settings Internet Protocol Version 4 TCP IPv4 Properties P xs General Alternate Configuration You can get IP settings assigned automatically if your network supports this capability Otherwise you need to ask your network administrator for the appropriate IP settings Obtain an IP address automatically Use the following IP address Obtain DNS server address automatically Use the following DNS server addresses Preferred DNS server Alternate DNS server Validate settings upon exit EE o J cane Close the dialog by clicking op and Gees Close the Control Panel 4 3 Tracker Pilot Network Settings General The following types of connections are available Network Connection Type LAN Connection WLAN Connection e Get Address from DHCP e Get Address from DHCP e Static IP Address e Static IP Address Refer to Network Settings on page 43 for details on accessing the Network Settings page AT Controller The display on the AT Controller 400 shows the following network display connection states 192 168 0 1 Network address assigned and connection established 192 168 0 1 Network address assigned but no connection established i e network cable unplugged Loading AT
82. layed when attempting to start a compensation in one of the Outdoor modes Changing the In Outdoor mode will be stored persistently in a data file on the application computer Click on Inclination to access the inclination sensor settings Absolute Tracker AT401 41 Monitoring Time x deg deg Initial 30 03 2010 15 25 06 0 001144 0 002389 Reset Current 30 03 2010 15 29 23 0 000938 0 002355 Update Drift 257160 ms 0 000206 0 000033 Inclination Si On of D The following controls are available Click the radio button Off to disable the inclination sensor Angular measurements will no longer be corrected by incli nation values The state change will be applied instantly Click on the radio button On to enable the inclination sensor and apply full angle corrections to the measurements The state change will be applied instantly Click Reset to replace the initial inclination readings with a new initial current reading Click Update to get a current reading from the inclination sensor The difference between Initial and Current will be displayed under Drift Return to the main page of Tracker Pilot S It is highly recommended to work with enabled inclination sensor in appli cable environments to achieve highest accuracy of the Absolute Tracker Ce Working in an unstable environment i e vibrating ground floating dock etc may require to disable the inclination sensor The Absolute
83. lds will be grayed out Click Apply to activate the network connection The LCD display of the AT Controller 400 displays a message while the system is being reconfig ured Tracker Pilot will return to the Select Sensor page The IP Address will be displayed on the LCD screen of the AT Controller 400 i e BSS AL 1 tt 0 0 0 0 2 1 33 101 22 A new connection needs to be created using the IP address displayed on the LCD screen of the AT Controller 400 Refer to New Connection on page 19 for details on creating a new connection Absolute Tracker AT401 65 4 3 3 WLAN Connection with Static IP Address General IP Address settings L Encryption 66 The Absolute Tracker system can be operated in a wireless network envi ronment A wireless access point is required for this configuration In this case the AT Controller 400 uses a static IP address Refer to Network Settings on page 43 for details on WLAN restrictions in certain countries To activate the WLAN communication on the AT Controller 400 tick the Activate WLAN box Activate WLAN To configure the AT Controller 400 to use a static IP Address over WLAN W LAN Configuration MAC 00 12 F3 07 53 CB d Activate WLAN SSID Leica AT401 Network Mode IP Address 27 Get Address from DHCP IP Mask 255 255 255 0 Static IP Address IP Mask S j Gateway Address 27 33 101 1 Encryption Method None WEP
84. med up and acclimatized 3 Navigate to the main page and select the BRR 1 5in reflector to use for the compensation S N 6634 c A corner cube type RRR CCR or BRR reflector is required for the ADM Compen sation Select the compensation to use for the 2010 04 29 15 37 compensation Angle 18 4 C RRR 1 5i Select the measurement time to use Measure Time 5000 ms CS A measurement time of 2000 ms is recommended for compensations inital F3 the system ial Ensure a reflector is in the field of view when starting the initialization process A message is during the initiali zation Navigate to the Compensations page 2010 04 29 15 37 Angle 18 4 C RRR 3 Ei a Start the ADM Compensation wizard Move the reflector to Point 1 In The DRO window and the sketch provide guidance to find the correct position 10 Press the Measure F2 button to measure Point 1 In Repeat steps 9 amp 10 for Point 2 In 12 Optionally analyze measurement details in the Measurements table delete or repeat measurements accordingly 13 Move the Absolute Tracker AT401 to Station 2 ADM Measurements Out the reflector remains on the same point Navigate to the ADM Measurements Out page Absolute Tracker AT401 113 15 Point the laser beam to the vicinity of Point 1 Out and click on Find Reflector F6 A message is displayed during the find process Press the Measure F2 button to m
85. ment F2 with the selected measurement time Refer to Setting measurement time on page 39 for details on setting the measurement time User Interface Absolute Tracker AT401 23 Status bar The following controls are available in the status bar Displays the current active user level Click to access the User Selection page Refer to User Levels on page 16 for details on user levels Displays the status of the selected connection Click to access the Select Sensor page Refer to Select Sensor Page on page 19 for details on available connections Displays the current Power Source of the Absolute Tracker AT401 and AT Controller 400 Refer to Power Source on page 26 on details on the power source options Displays the current state of the inclination sensor Click to access Inclination Sensor page Refer to Inclination on page 41 for details on incli nation sensor settings Displays the current state of the In Outdoor Mode Click to access the In Outdoor Mode page Refer to In Outdoor Mode on page 40 for details on the In Outdoor Mode settings il 16 5 c Displays the actual values and current source of envi 370 mBar 57 ronmental parameters Click to access the Meteo Monitor page Refer to Meteo Monitor on page 42 for details on environmental data settings BRR 1 5in Displays the current active reflector Click to access Sie LL _ the Reflectors page Refe
86. nsations to access the Compen sations page F 2010 04 29 15 37 Ty Angle 18 4 C RRR 15i The Compensations page for user level Advanced looks as follows Tracker Pilot Leica AT401 5 x Leica AT401 Leica AT401 N Seica S N390402 10 62 35 58 a Compensations New Angle Compensation anew ADM Compensation E et 2010 02 26 10 16 2010 04 14 14 01 2010 04 11 12 04 oak 2010 03 26 21 14 gt 2010 03 26 21 14 Es 2010 04 11 14 04 23 3 C TER 0 5in 23 3 C TBR 0 5in OVC 23 5 C RRR 1 Sin OAC 53 2 cP ew rat The following controls are available Absolute Tracker AT401 35 Ka 2010 04 15 09 12 La 2010 04 15 09 12 angle 20 1 C RRR 1 5in vue 50 7 C KBE Ta 2010 04 15 09 12 pa 2010 04 15 09 12 2010 04 15 09 12 gt 2010 04 15 09 12 Angle 20 1 C RRR 1 5in ge 50 T C BBB rau Set ven KS dat Angle Compensation EH New ADM Compensation Displays the current active compensation record The following details are shown Compensation name consisting of the date amp time the compensation has been finished Start time of the compensation Type of compensation Environmental parameters Active reflector Click onto a compensation element to activate this compensation record The state change will be applied instantly and Tracker Pilot returns to the main page CS Activating a compensation requires to re initialize the Absolute Tracker
87. nt setup Nominal position Scale Instrument position Measured position Absolute Tracker AT401 Compensation Tool tips Dynamic tool tips provide additional information on the required posi tions compensation measurements and accuracy information related to the measurements Tool Tip e Id H deg V deg D mm Std Dev mm 1 0 0000 90 0000 2000 000 32 0 6902 89 6274 2019 734 Std Dev 0 0146 0 0084 0 452 Accuracy 1 0000 2 0000 33 676 Temperature 16 6 C Pressure 346 mBar Humidity 0 H deg V deg D mm Std Dev mm 0 29601 0 00000 Nominal Position Point ID Required Horizontal Angle Required Vertical Angle Required Distance Measured Position Point ID Measured Horizontal Angle Measured Vertical Angle Measured Distance Standard Deviation for each component a posteriori Accuracy a priori Temperature Pressure Humidity Data Read Out A Data Read Out DRO window provides numerical information about the DRO window current approximate position and the deviation to the target position Position deviations over the tolerance will be flagged with red background color The Data Read Out DRO window shows the following status informa tion DRO Status I 115 4839 105 7289 3606 303 Current Last Measured Face I I H 115 3139 BEE V 97 7299 R977299 D 3606 348 3606 344 U 95 0 003 gon gon mm mm Not ready no reflector locked or not ready
88. nts at the height of tilting axis of the Absolute Tracker AT401 from the middle of the two points 2 Measurement of the same two fixed points at the height of tilting axis of the Absolute Tracker AT401 from the outside of the two points Absolute Tracker AT401 Compensation Recommended The recommended setup for the ADM Offset Compensation is shown setup below Tolerance Compensation Absolute Tracker AT401 119 Procedure step by step 120 Setup the Absolute Tracker system on Station 1 ADM Offset Compensation Measurements In according the setup sketch shown above 2 Ensure the Absolute Tracker system is warmed up and acclimatized Select the compensation to use for the 2010 04 29 15 37 compensation Angle 18 4 C RRR 1 5ii Select the measurement time to use Measure Time 5000 ms Ce measurement time of 2000 ms is recommended for compensations Initialize F3 the system E Ensure a reflector is in the field of view when starting the initialization process A message is during the initiali zation Navigate to the Reflectors page RRR 1 5in SIN 3316 Click on the button New Custom Reflector a Enter a name for the Custom Reflector Enter an optional comment for the Custom J comment Reflector 10 Enter the radius of the Custom Reflector refector radius 0 000 mm housing in the given units Click on the button Compensate to start Com Compensate the ADM Offset Comp
89. nts from two different Tracker stations Large ambient tempera ture changes may result in significant ADM check deviations ADM check measurements consist of the following 2 step process 1 Measurement of two fixed points at the height of tilting axis of the Absolute Tracker AT401 from the middle of the two points 2 Measurement of the same two fixed points at the height of tilting axis of the Absolute Tracker AT401 from the outside of the two points The recommended setup for the Two Face check is shown below Vertical Angle deg Distance m RO o Absolute Tracker AT401 Check Point ID Vertical Angle deg Distance m ES woo o 2 Out ECK Check Absolute Tracker AT401 89 Procedure step by step 90 Setup the Absolute Tracker system on Station 1 ADM Measurements In according the setup sketch shown above Ensure the Absolute Tracker system is warmed up and acclimatized to the envi ronment 3 Navigate to the main page and select the BRR 1 5in reflector to use for the check SIN 6634 CS A corner cube type RRR CCR or BRR reflector is required for the ADM Check Select the compensation to use for the 2010 04 29 15 37 check Angle 18 4 C RRR 1 5i Select the measurement time to use Measure Time 5000 ms CS A measurement time of 2000 ms is recommended for checks Initialize F3 the system E Ensure a reflector is in the field of view when starting the initialization proce
90. nually Windows XP C Documents and Settings Local User Applica tion Data Tracker Pilot Reports Windows Vista C Users Local User AppData Roaming Tracker Pilot Reports Windows 7 C Users Local User AppData Roaming Tracker Pilot Reports Refer to Viewing PDF Reports on page 50 for details on viewing saved Compensation reports 6 1 3 ADM Compensation General The ADM Compensation routine verifies the zero point offset of the ADM in relation to the origin of the Tracker coordinate system Large ambient temperature changes may require to perform an ADM Compensation Compensation ADM Compensation measurements consist of the following 2 step procedure process 1 Measurement of two fixed points at the height of tilting axis of the Absolute Tracker AT401 from the middle of the two points 2 Measurement of the same two fixed points at the height of tilting axis of the Absolute Tracker AT401 from the outside of the two points Compensation Absolute Tracker AT401 111 Recommended The recommended setup for the ADM Compensation is shown below setup 1 Station 1 ADM Measurements In 2 Station 2 ADM Measurements Out hi OO En E row bo o o o zom po ko o 112 Absolute Tracker AT401 Compensation Procedure step by step Compensation Setup the Absolute Tracker system on Station 1 ADM Measurements In according the setup sketch shown above 2 Ensure the Absolute Tracker system is war
91. on process The compensation parameters will be stored on the system and the PDF Report will be generated A message is displayed Measurements All measurements taken are listed in the Measurements table on the table bottom half of the screen Compensation Absolute Tracker AT401 121 Measurements Id H deg V deg D mm Std Dev mm Delete i In 0 1877 89 3147 1967 900 0 14455 2 In 178 8947 90 6574 2022 530 0 51350 l Station 1 ADM Offset Compensation Measurements In Measurements Id H deg V deg D mm Std Dew mm Delete 1 Out 0 8463 89 8153 1994 336 0 96833 E 2 0ut 0 2611 389 6834 5996 920 0 70718 E 2 Station 2 ADM Offset Compensation Measurements Out The following actions can be taken Description Click on the point ID to open a pop up window showing details about the selected measurement record Click on the trash bin icon to delete a single measurement record xk Move the mouse over indiviual measurement values to e e display a tool tip with the measurement value and tolerance sat used where applicable Reeg Navigate back to Station 1 to optionally analyze measure _ ment details in the Measurements table ee Navigate forward to Station 2 to optionally analyze meas _ urement details in the Measurements table 57 22 Result The Report page summarizes the results of the ADM Offset Compensa tion The ADM Compensation is passed
92. on of the laser beam in the glass body This results in a lag of the path of the laser beam The ADM Offset Compensation for Custom Reflectors routine verifies this additional path of the ADM beam The ADM Offset can either be manually entered or determined by the ADM Offset Compensation process Refer to ADM Offset Compensation for Custom Reflector on page 118 for details on the ADM Offset Compensation process Compensations General 32 The Compensations page allows to view and maintain compensation records The following functions are available Absolute Tracker AT401 User Interface View Compensation details Create new Compensation 3 8 1 Compensations on Standard User Level General Click on the Status Bar element for Compensations to access the Compen sations page 2010 04 79 15 37 Angle 18 4 C RRR 1 5i1 The Compensations page for user level Standards looks as follows Tracker Pilot Leica AT401 Leica AT401 Leica AT401 Leica S N 390402 10 62 35 58 zeg Compensations 2010 02 26 10 16 2010 04 14 14 01 2010 04 11 12 04 2010 03 26 21 14 gt X 2010 03 26 21 14 Ee 2010 04 11 14 04 23 3 C TBR 0 5in 23 3 C TBR 0 5in z OVC 23 5 C RRR 1 5in OAC 53 2 C KKK rau The following controls are available User Interface Absolute Tracker AT401 33 Compensation details 34 2190415012 Displays the current active compensation record The ans following details are s
93. on parameter report will be shown Compensation Date Name Comment Reflector Type PowerLock Date Hu Yo ATR Angle Date Incl Index L Incl Index C Inclination Sensor Ox Oy Coll Buckling H Coeff Coll Buckling H Exp Coll Buckling V Coeff Coll Buckling V Exp ADM Date Offset OVC Date H Offset V Offset Category Compensation 2010 04 14 09 45 2010 04 14 09 45 Angle 19 2 C RRR 1 5in BRR15 2010 04 14 09 44 378 42 246 68 2010 04 14 09 44 373 31 244 92 2010 04 14 09 45 6 366198 gon 12 732395 gon On 0 007024 gon 0 000708 gon 0 015812 gon 2010 04 14 11 43 0 03758 mm 0 09673 mm 1 25925 mm 9 096151 gon 10 45 0 005497 gon 3 00 2010 04 14 11 43 73 000 mm 2010 04 14 11 44 200 0213 gon 100 0040 gon Parameters Compensation Date Name Comment Reflector Type Absolute Tracker AT401 37 3 9 General Range 38 PowerLock Compensation Date Zero Pixel Coordinate Xo Zero Pixel Coordinate Yo ATR Compensation Date Zero Pixel Coordinate Xo Zero Pixel Coordinate Yo Angle Compensation Date Inclination Index Length Inclination Index Cross Inclination Sensor State Collimation error c Trunnian Transit Axis tilt i Vertical index error J Axes e Compensation Date e Standing axis to trunnian axis Offset e e Standing axis to collimation axis Offset O e Trunnian axis to collimation
94. on the button to open the Windows Start menu OPERATOR Internet My Documents Internet Explorer CI A 4 My Recent Documents gt Gid E mail LA Lotus Notes 43 My Computer e Notepad a My Network Places ES Microsoft Office Excel 2003 amp Control Panel GN Set Program Access and F i Adobe Acrobat 7 0 Defaults Professional w t Connect To b DI iPassConnect LGS V 2 Printers and Faxes Snaglt 7 Help and Support 1 Paint oi SE Log Off Shut Down Select Run this will open the following dialog box All Programs gt Type the name of a program folder document or Internet resource and Windows will open it for you God Type cmd for command prompt and dck o JL The following window appears Absolute Tracker AT401 71 Cables Settings 72 et C WINDOWS system32 cmd exe C gt ping 192 168 6 1_ Note the IP address that is displayed on the LCD screen of the AT Controller 400 and type in ping lt IP Address gt i e ping 192 168 0 1 and hit Enter The following page will be displayed in case a successful communication c C WINDOWS system32 cmd exe C gt ping 192 168 0 1 Pinging 192 168 0 1 with 32 bytes of data Reply from 192 168 0 1 bytes 32 time ims TTL 128 Reply from 192 168 0 1 bytes 32 time lt ims TTL 128 Reply from 192 168 0 1 bytes 32 time lt ims TTL 128 Reply from 192 168 0 1 bytes 32 time lt ims TTL 128 Ping stati
95. ontact gt Sales amp Support Contacts gt Headquarters Sales amp Support Contacts gt Sales amp Support Contacts Regional Contacts for Metrology Sales Support A Service Centers A Customer Enquiry Form Looking for Sales 7 Country United Kingdom x Product Line Laser Tracker Systems id Search sookmark gii pa O A D 22 0 Select the field of interest Sales Support or Technical Service country and product line and click on the icon Search The contact details of the responsible Leica Geosystems representative in your region will be displayed Help Absolute Tracker AT401 129 7 1 3 Update System General L Update package Prerequisites Windows UAC Procedure 130 Updates to the ADsolute Tracker AT401 firmware the AT Controller 400 software and the Tracker Pilot software are integrated into a single update file This function is only available to user level Advanced The Absolute Tracker AT401 update package has the following file name e AT400_Vx x xxxx x Update x x xxxx x representing the version number i e AT400_V1 0 0142 0 Update The following prerequisites need to be met for a system update of the Absolute Tracker system e The Absolute Tracker system needs to be powered by mains It is not possible to update the system running on battery power e It is not possible to update the Absolute Tracker system over a WLAN connection In case the Tracker Pilot has not been in
96. or unit Disabling the Remote Control buttons will not be stored persistently By default the Remote Control buttons will enabled at startup of the Abso lute Tracker Absolute Tracker AT401 User Interface Wake Up User Interface Click on Wake Up to access the standby and wake up settings Wake Up Date amp Time 4 2010 P 4 March P Sun Mon Tue Wed Thu Fri Sat 1 A 3 4 5 6 H ra g 10 11 lz 13 Ja 15 16 17 18 19 A0 Al 22 23 24 25 26 27 28 29 Ei 31 15 42 Apply amp go standby w The following controls are available 42010 gt Click the green arrows to select the year for the wake up Click the green arrows to select the month for the wake up Click onto the calender view to select a day for the wake up The selected day is marked orange d 34 Click into the hour or minute field of the time Type in the time for the wake up Alternatively the time can be set using the grey arrows Once the date and time for the wake up Is set click on Apply amp go standby The state change will be applied instantly The Tracker Pilot returns to the Connection page op Return to the main page of Tracker Pilot ck oo to wake up the Absolute Tracker ually Apply amp go standby DI The Absolute Tracker AT401 will be turned off during the standby to prolong the lifetime of the laser components The AT Controller 400 remains powered up As soon as the system is powered up the Absolute Tracker AT401 is
97. ore further records can be marked for import The import file area will be grayed out Absolute Tracker AT401 Help Help Tracker Pilot PZP Connection Leica AT401 P2P Connection S N 390406 192 168 0 1 Support Center Import Reflectors 9 Total 25 of maximum 25 items z RRR 1 5in RRR 1 5in RRRIS SIN 3142 TBR 0 5in TBR 0 5in TeROS Tooling Ball BRR 1 5in BRR 1 5in BRR15 S N 6634 BRR 1 5in BRR 1 5in 7 erris S N 6634 RRR 1 5in TBR 0 5in RRRIS S N 3142 TBR 0 Sin RRR 1 5in e TBROS Tooling Ball BRR 1 5in a BRRIS SIN 6634 BRR 1 5in BRRIS S N 6634 TBR 0 5in TBROS The following warning message will be show in this case Warning 11010 gt 4 Q Maximum Reflectors Reached Details The sensor already is full and no new reflectors can be imported Solution Please move some reflectors to the trash bin first to be able to e import new ones Move one or more compensations or reflectors to the trash bin Once a record has been dragged amp dropped into the trash bin additional records can be imported from the import file In case the maximum number of compensations and reflectors is reached during import the Tracker Pilot disables dragging amp dropping additional records from the import file The remaining capacity of compensations and reflectors can be seen on the status bar of the import dialog Leica AT401 P2P Connection SON 390406
98. ors zl Places Files of type Compensations amp Reflectors x Cancel A Select the desired item and click Open The following screen appears Tracker Pilot P2P Connection Leica AT401 P2P Connection S N 390406 192 168 0 1 Support Center Import Reflectors A Total 3 of maximum 25 items kl TA RRR 1 5in RRR 1 5in S Q RRRIS O RRRIS SIN 3142 S N 3142 RRR 1 5in E BRR 1 5in D k B g RRRIS D epps S N 2231 TBR 0 5in QO TBROS Tooling Ball a b c a Trash bin b Reflectors currently stored on the Absolute Tracker AT401 c Reflectors contained in the import file The following actions can be taken e Drag amp drop a reflector from the import file c onto the Absolute Tracker AT401 b to mark this reflector to be imported to the sensor e Drag amp drop a reflector from the Absolute Tracker AT401 b onto the Trash bin to mark this reflector to be removed from the sensor The Tracker Pilot does not allow to import a reflector with the same name as an existing reflector on the system The screen shows a preview of the changes Absolute Tracker AT401 137 138 The following controls are available Import selected reflectors to the Absolute Tracker AT401 Ce Changes will only be applied when clicking on the button Import Click on the button Import to apply the changes on the Absolute Tracker AT401 The following screens shows the progress
99. product has to become warmed up and accli matized to the ambient temperature especially if the product has been stored under different temperature conditions Ensure sufficient acclima tization to the environment before taking precision measurements To achieve the highest possible accuracy level a warm up time of two hours is strongly recommended before starting a compensation or a high preci sion measurement job The systems needs to be initialized before a compensation wizard can be started A compensation can only be performed in Indoor mode Refer to In Outdoor Mode on page 40 for details on In Outdoor mode The required room space for the compensation of the Absolute Tracker AT401 is 2 x 16 meter Minimum room height is 2 meter To achieve the highest possible accuracy the following steps are recom mended e Set up the Absolute Tracker on a stable ground and level it accurately e Environmental parameters should remain constant during the compensation e The Absolute Tracker should be warmed up for gt 2 hours before starting the compensation A pop up message will be displayed once the system is warmed up e A Leica RRR 1 5 reflector should be used for compensations Absolute Tracker AT401 Compensation 6 1 General Compensation records Process Sketches Compensation e The reflector should be clean and undamaged e The ideal reflector position for the initialization should be at gt 1
100. r on page 30 for details on creating new reflectors Click on New Break Resistant Refl 1 5in to create a new 1 5 BRR reflector Refer to Create new standard reflector on page 30 for details on creating new reflectors Click on New Break Resistant Refl 0 5in to create a new 0 5 BRR reflector Refer to Create new standard reflector on page 30 for details on creating new reflectors User Interface Absolute Tracker AT401 29 Click on New RFI Refl 0 5in to create a new 1 5 RFI Reflector for fixed installations reflector Refer to Create new standard reflector on page 30 for details on creating new reflectors vy New RFI Reflector 0 5in q New Custom Reflector Click on New Custom Reflector to create a new custom reflector Refer to Create new custom reflector on page 31 for details on creating new reflectors Apply changes to the Absolute Tracker and return to the main page of Tracker Pilot 1 A message is displayed while the data on the Absolute Tracker AT401 is updated Create new stan Click on the element of one of the standard reflector types to create i e dard reflector ER New Break Resistant Refl 1 Gin The Reflector Definition page opens up Tracker Pilot P2P Connection A default name for the reflector will be proposed The name can be edited by the user Ce Multiple reflectors with the same name cannot be created In this case Tracker Pilot propo
101. r local Leica Geosystems representative PowerLock Click on PowerLock to access the PowerLock settings PowerLock w On OF The following controls are available oF Click on the radio button Off to disable PowerLock The state change will be applied instantly On Click on the radio button On to enable PowerLock The state change will be applied instantly Return to the main page of Tracker Pilot User Interface Absolute Tracker AT401 45 L Remote Control 46 In certain situations where multiple reflectors are located in the field of view of PowerLock it might be favorable to disable PowerLock to avoid that the reflector locks onto an unwanted reflector Disabling PowerLock will not be stored persistently By default PowerLock will enabled be at startup of the Absolute Tracker Click on Remote Control to access the settings for the AT400 Remote Control Remote Buttons On Off The following controls are available oF Click on the radio button Off to disable the Remote Control buttons The state change will be applied instantly Dri Click on the radio button On to enable the Remote Control buttons The state change will be applied instantly Se Return to the main page of Tracker Pilot In certain situations where multiple Absolute Trackers are located in the range of the AT400 Remote Control it might be favorable to disable the Remote Control buttons to avoid an unwanted reaction of a sens
102. r Pilot proposes a new name i e RRR 1 5in 1 User Interface Absolute Tracker AT401 31 ADM Offset compensation 3 8 ame asm A user definable comment can be added i e the serial number of the reflector other reflector types the reflector radius is given Ce For Custom reflectors only coo mm Either add an ADM Offset for Custom reflectors manu ally or start the ADM Offset compensation wizard For all other reflector types the ADM Offset is given Ce For Custom reflectors only Refer to ADM Offset Compensation for Custom Reflector on page 118 for details on the ADM Offset compensation Process Compensate Click on Compensate to start the ADM Reflector Offset compensation wizard EE Click on Finish to create the selected reflector on the Absolute Tracker AT401 geg A message is displayed while the data on the Absolute Tracker AT4O1 is updated Return to the main page of Tracker Pilot without applying any changes Refer to Export of Compensations amp Reflectors on page 133 on details on exporting reflectors Refer to Import of Compensations amp Reflectors on page 135 on details on importing reflectors Custom reflector types with an individual ADM Offset compensation can only be imported to the instrument where the records have been created originally It is not possible to upload a custom reflector to a different instrument All glass prism reflectors cause a refracti
103. r to Reflectors on page 27 for details on reflec tors No reflector available A reflector needs to be created or imported Requires Advanced user level privileges Refer to Create new standard reflector on page 30 for details on creating reflectors Mar 23 2010 09 52 Displays the current active compensations Click to _ 2S IG RIS access the Compensations page Refer to Compensations on page 32 for details on compensations No compensation record available A compensation record needs to be created or imported Requires Advanced user level privileges Refer to Compensation on page 96 for details on compensations 24 Absolute Tracker AT401 User Interface Measure Time Displays the selected measurement time Click into the 5000 ms input field to change the measurement time Refer to Measurement Time on page 38 for details on the measurement time User Interface Absolute Tracker AT401 25 3 6 Power Source General 26 The Power Source element of the status bar displays the current power source of the Absolute Tracker system Absolute Tracker AT401 or AT Controller 400 battery capacity between 0 7 C The tool tip will show the exact battery capacity Ce The battery should be changed immediately Absolute Tracker AT401 or AT Controller 400 battery capacity between 7 20 E The tool tip will show the exact battery capacity Absolute Tracker AT40
104. racker User Manual 2 Click Tracker Pilot to install the Tracker Pilot from this CD and follow the instructions on the screen Note do not install to a network drive because depending on network rules for users operation of Tracker Pilot cannot be 100 guaranteed Tracker Pilot Manual Browse CD Exit Copyright 2010 Leica Geosystems All Rights Reserved This program is protected by inter national copyright laws as described in the About Box The following controls are available Absolute Tracker AT401 Installation zem Starts the installation of Tracker Pilot Opens this reference manual Manual Opens a file explorer to display the content of the Product CD Exits the application Tracker Pilot instal Click on the button Tracker Pilot to start the installation lation The installation routine will check if an instance of the Tracker Pilot already exists on the application computer If a Tracker Pilot installation is found the following message will be displayed Setup detected that you already have a version of TrackerPilot installed Please use TrackerPilot directly to update to a newer version SupportCenter gt UpdateSystem instead of installing from your product CD Do you want to install TrackerPilot anyway Yes Click to install the Tracker Pilot anyway or click to cancel fe Setup Tracker Pilot Version 1 3 1 122 Welcome to the Tracker Pilot Version 1 3 1 122 Set
105. ready to measure Nevertheless a minimum warm up time of 30 minutes is recommended before starting a measurement job To achieve the highest possible measurement accuracy a warm up time of at least 2 hours is highly recommended Absolute Tracker AT401 47 3 10 2 Settings Tracker Pilot General Accuracy 48 The menu Tracker Pilot provides access to general Tracker Pilot settings User Level A Tracker Pilot A Tracker Pilot Units Accuracy Units Click on Accuracy to access the accuracy level settings Accuracy Settings Accuracy Level 1 00 The a priori accuracy of measurements is multiplied by the accuracy level factor The level can be increased by the user in case of unstable environ ment The default value is 1 0 The a priori accuracy level has an influence on the highlighting threshold for various tolerances and MPE values The following controls are available Click into the input field and change the accuracy level setting as required Reset the accuracy level to the default value 1 0 Apply changes to accuracy level settings and return to the main page of Tracker Pilot OK The Accuracy Level has a direct influence on the passed failed criterion of checks and compensations Therefore the Accuracy Level should be changed carefully Changing the accuracy level will be stored persistently in a data file on the application computer Absolute Tracker AT401 User Interface Units
106. rk and Sharing Center Icon Control Panel Home e gt us Network and Int Network and Sharing Center X Search Control Panel 2 View your basic network information and set up connections Change adapter settings A x See full map Change advanced sharing settings WIN7_64 Internet This computer View your active networks Connect to a network You are currently not connected to any networks Change your networking settings KC Set up a new connection or network Set up a wireless broadband dial up ad hoc or VPN connection or set up a router or access point Sr Connect to a network Connect or reconnect to a wireless wired dial up or VPN network connection we Choose homegroup and sharing options Access files and printers located on other network computers or change sharing settings See also Troubleshoot problems HomeGroup Diagnose and repair network problems or get troubleshooting information Internet Options Windows Firewall Click on the menu item Change adapter settings on the left hand side Absolute Tracker AT401 Network Settings Network Settings e ka EE Network and Internet Network Connections gt v f Search Network Connections p Organize Banz Local Area Connection Network cable unplugged x Broadcom NetXtreme Gigabit Eth Right click on the Local Area Connection or the name of the network card to be used for the connection to the AT Controll
107. ser Tracker Controller hard models Wake 1 Absolute Tracker AT401 with AT Controller 400 Description of the system Absolute Tracker AT401 7 2 Installation 2 1 Windows UAC Tracker Pilot Software Installing the Tracker Pilot into the proposed default location does not require administrator privileges Installing the Tracker Pilot into a different folder may require authorization of a system administrator Please contact your system administrator for details Operating Default Directory System Windows XP C Documents and Settings Local User Start Menu Programs Leica Tracker Pilot Windows Vista C Users Local User AppData Roaming Micro soft Windows Start Menu Programs Leica Tracker Pilot Windows 7 C Users Local User AppData Roaming Micro soft Windows Start Menu Programs Leica Tracker Pilot A shortcut to Tracker Pilot will be created on the desktop by default 2 1 1 Windows XP General The provided Tracker Pilot product CD contains the installation files for the Tracker Pilot software Insert the CD into the CD drive of the applica tion PC the Autorun should launch the Installer menu automatically Start the application AT401Software exe manually in case the AutoPlay option is not activated on your PC A1T401Software Geosystems Getting Started with a New Leica Absolute Tracker 47401 1 Configure the Leica Absolute Tracker 4T401 according to the 47401 Absolute T
108. ses a new name i e RRR 1 5in 1 A user definable comment can be added Le the serial number of the reflector 30 Absolute Tracker AT401 User Interface Reflector Radius s3 imm Displays the Reflector Radius of the housing This value cannot be changed for standard reflector types ADM Offset 530 mm Displays the ADM Offset of the reflector This value cannot be changed for standard reflector types Click on Finish to create the selected reflector on the Absolute Tracker AT4O1 1 A message is displayed while the data on the Absolute 1 Tracker AT401 is updated Return to the main page of Tracker Pilot without applying any changes Refer to Export of Compensations amp Reflectors on page 133 on details on exporting reflectors Refer to Import of Compensations amp Reflectors on page 135 on details on importing reflectors Create new custom Click on the Create Custom Reflector element to create a new custom reflector type reflector This reflector type allows to either enter an ADM Offset for glass prism manually or determine it by a compensation process EI New Custom Reflector The Reflector Definition page opens up Tracker Pilot P2P Connection P2P Connection IN 390413 192 168 0 1 Reflector Definition A default name for the reflector will be proposed The name can be edited by the user Ce Multiple reflectors with the same name cannot be created In this case the Tracke
109. ss A message is displayed during the initiali zation process Piease wait initializing Start the ADM Check wizard Check Two Face ADM to find the correct position Press the Measure F2 button to measure e Point 1 In gt Repeat steps 8 amp 9 for Point 2 In E 11 Optionally analyze measurement details in the Measurements table delete or repeat measurements accordingly Move the reflector to Point 1 In The DRO window and the sketch provide guidance Move the Absolute Tracker AT401 to Station 2 ADM Measurements Out the reflector remains on the same point E Navigate to the ADM Measurements Out page Absolute Tracker AT401 Check 14 Point the laser beam to the vicinity of Point 1 Out and click on Find Reflector F6 A message is displayed during the find process Press the Measure F2 button to measure Point 1 Out Move the reflector to Point 2 Out The DRO window and the sketch provide guid ance to find the correct position Press the Measure F2 button to measure Point 2 Out Optionally analyze measurement details in the Measurements table delete or repeat measurements accordingly Navigate to the Report page when all measurements are taken The ADM Check is marked as Passed or Failed depending on the measurement results Click on the Show Report icon to view detailed results of the Two Face Check Finish the ADM Check process Th
110. stalled into the default location administrator privileges may be required to update the Absolute Tracker system as the Update package may contain an update for the Tracker Pilot as well Click on the following icon to start the system update v Install an update package for the fitt following system components EEN e Absolute Tracker AT401 a e AT Controller 400 e Tracker Pilot The Tracker Pilot does not need to be updated separately After updating the Absolute Tracker the Tracker Pilot will update itself without user interaction It is recommended only to install a single instance of the Tracker Pilot on the application computer Clicking onto the Update System icon opens the following dialog Absolute Tracker AT401 Help Help Please choose a file Look in O Leica D e ey ES E AT400_ 1 0 142 0 Update My Recent Documents 3 Desktop My Documents My Computer My Network File name AT400_V1 0 142 0 Update Open Places Files of type Leica Geosystems Updates at o Cancel Select the update package to install and dick Hoen Alternatively the Update file can Just be dragged and dropped from a Windows Explorer anywhere onto the window of the Support Center The following message is displayed while the Update Manager launches Once the Update Manager has started up the following screen will appear eer Install Updat e Version 1 1 5419 0 ji 1 T
111. stics for 192 168 0 1 Packets Sent 4 Received 4 Lost z loss Approximate round trip times in milli seconds Minimum ms Maximum ims Average Gms ANA The following page will be displayed if no communication could be estab lished ce C WINDOWS system32 cmd exe C gt ping 192 168 6 1 Pinging 192 168 0 1 with 32 bytes of data Request timed out Request timed out Request timed out Request timed out Ping statistics for 192 168 0 1 Packets Sent 4 Received Lost 4 168 loss th Possible reasons for a failed communication could be e Incorrect AT Controller 400 IP settings e Incorrect TCP IP protocol settings e Faulty LAN cable or RJ45 connectors Some older network adapters may require a crossed over Tab twisted pair LAN cable to communicate Modern network adapters automatically detect the type of cable The network adapter of the application PC may be disabled or the network communication may not have been initialized at startup of the application computer Absolute Tracker AT401 Network Settings Network Settings Click on the button to open the Windows Start menu OPERATOR Internet My Documents Internet Explorer q 4 My Recent Documents gt Microsoft Office Excel 2003 EI My Computer fa Notepad a My Network Places w Paint LA Control Panel Set Program Access and A Adobe Acrobat 7 0 Defaults Professional E Va Printers
112. terface 3 4 General Leica Remote Control User Interface Leica AT401 Leica AT401 l 10 62 35 45 Connecting to Leica AT401 mg Connecting to Tracker Keyboard amp Remote Control Shortcuts The following functions can be addressed by function keys F12 Toggle between full sketch view full DRO view and shared view The following functions are mapped to the function keys of the Leica Remote Control a b C d e d IR Transmitter e Button A f Button B g Button D D h Button C Absolute Tracker AT401 21 3 5 Start Measurement F2 Bo Next F9 on Tracker Pilot wizard pages Back F10 on Tracker Pilot wizard pages Toggle between full sketch view full DRO view and shared view F12 Main Page Windows title bar Tracker Pilot title bar Data Read Out Window DRO 22 The main page consists of the following elements a Tracker Pilot title bar current ins pics connection details s Face I eben b Window title bar c Window controls 97 7345 d Absolute Tracker controls 3526 744 e Data Read Out DRO window f Absolute Tracker status bar S g Menu bar The Windows title bar displays the following elements e Application Name e Name of the current active connection The Tracker Pilot title bar displays the following elements e Name of the current active connection e Type of connected Absolute Tracker e Seri
113. th IP address 192 168 0 1 to the Absolute Tracker AT401 D Click on this symbol to create a new connection New Connection Leica AT401 P2P Connection Leica AT401 THe 192 168 0 1 The green background indicates an active connection eene Moving the mouse over an inactive connection enables Leica AT401 the Delete button Click Delete to remove a connection ee from the list Ce Only inactive connections can be deleted The current active connection cannot be deleted New Connection Click on the symbol for New Connection to create a new connection User Interface Absolute Tracker AT401 19 Connection 20 Select Sensor The following controls are available Name Enter a name under which the new connection is Leica AT404 displayed on the connection page The name is arbi trary IF Address Enter the IP address for the desired connection The IP 27 5233104 address can be found on the LCD display of the AT Controller 400 Click Create to create and add the new connection to the connection page The Tracker Pilot returns to the connection page afterwards ES Click Cancel to return to the connection page without applying any changes Back Back Click Back to return to the main page without applying any changes During the connection process to the Absolute Tracker the following page is displayed showing the progress of the connection process Absolute Tracker AT401 User In
114. the Measure F2 button 106 Absolute Tracker AT401 Compensation C The Measure F2 button only becomes available when the reflector is located at the required position otherwise the button will remain grayed out Repeat steps 11 amp 12 for all other posi tions Additional points can be added if required Cs The Angle Compensation is a guided process The measurements have to be taken in sequential order The DRO window guides to the next point in sequence Optionally analyze measurement details in the Measurements table delete or repeat measurements accordingly Report icon to view detailed results of the Angle Compensation 13 14 15 Navigate to the Report page when all measurements are taken 16 The Angle Compensation is marked as Passed or Failed depending on the measurement results Click on the Show 17 Finish the Angle Compensation process The compensation parameters will be stored on the system and the PDF Report will be generated A message is displayed during this process Measurements All measurements taken are listed in the Measurements table on the table bottom half of the screen mW oa H deg V dea D mm U 95 mm H Dev deg V Dev deg D Dev mm Delete 1 235 1932 133 3705 2123 120 0 005 0 0093 0 0344 0 010 2 234 4526 119 7985 2894 127 0 007 0 0082 0 0241 0 010 3 237 4959 108 5410 4509 130 0 021 0 0075 0 0139 0 016 4 230 8992 89 0685 2174 790 0
115. ting for sensor to reconnect Sensor Has Been Disconnected This could be due to changing the controller battery or just by disconnecting the cable between controller and sensor or loosing LAN WLAN connection Please check all cables and batteries This window will disappear automatically if the sensor is connected again Otherwise please terminate connection and go back to the connection selection page by clicking Terminate Terminate The Tracker Pilot continuously tries to reestablish the connection the AT Controller 400 Once the connection is established again the Absolute Tracker system will be reset to its previous state To terminate the connection manually click the button Terminate Absolute Tracker AT401 Network Settings 5 Check General Measurement precision L L 5 1 Leica Geosystems products are manufactured assembled and adjusted to the best possible quality Quick temperature changes frequent move ment of the product shock or stress can cause deviations and a decrease of the measurement accuracy It is therefore recommended to check the product in regular intervals This can be done onsite by running through specific check or compensa tion measurements If checks do not provide satisfying results repeatedly a compensation of the product is recommended To achieve precise measurement results in the daily work it is important to check and adjust the product
116. tion computer complete the following steps Absolute Tracker AT401 Network Settings 4 2 1 Windows XP Control Panel Click on the button to open the Windows Start menu OPERATOR Internet De My Documents Internet Explorer GC i A My Recent Documents gt Microsoft Office Excel 2003 I My Computer Lei Notepad a My Network Places Paint A Control Panel Set Program Access and Defaults a Connect To Va Printers and Faxes IA Adobe Acrobat 7 0 Professional Help and Support Search All Programs gt A Log Off Q Shut Down Launch the Control Panel amp Control Panel File Edit View Favorites Tools Help Q Back Ka ES Search 1 Folders EZ Address D Control Panel See Also Display Keyboard Bluetooth Konfiguration Date and Time Folder Options Fonts g Windows Update DI Help and Support Game Controllers Internet Options Si e J b dE NVIDIA nview Desktop NVIDIA Phone and Modem Power Options Manager Systemsteuerung Options KN Network Connections File Edit View Favorites Tools Advanced Help ay Q sxx x Si JO search 1 Folders E e Network Connections x Go Name Type Status Device Na LAN or High Speed Internet Address Network Tasks Ei Create a new connection amp amp Local Area Connection LAN or High Speed Inter Connected Shared Intel R 8 wi leie Windows Firewall ok 1394 Connection
117. tion occurs during this oper ation 3 14 1 Impediments General Impediments are shown to the user when moving the mouse over a func tion or a function button to execute a certain function of the Tracker Pilot i e pressing the measure button In case a required condition or a recommended state is not met an impediment will be shown in a tool tip Two different types of impediments are shown to the user Impediments in green font indicate Impediment 11023 a recommended action to the user Tracker Initialization recommended The selected function will still be Click to Ignore available E Impediments in red font indicate a mee weer mandatory action A red impedi Click to Resolve ment has to be resolved before the intended function can be executed The selected function button will be disabled grayed out until the impediment is resolved Click on the selected function button to resolve the impediment 3 14 2 Warning amp Error Messages General Warning or error messages are shown to the user in a pop up window in case of an exception All warning and error messages display a number a warning or error text and a recommended solution 54 Absolute Tracker AT401 User Interface e Warning 11010 x d Q Maximum Reflectors Reached C SC already is full and no new reflectors can be d OK button and count down imported b Detailed solution recommenda Solution S b D Q Please mo
118. to measure Ce Move the mouse over the Measurement button to display a tool tip providing information about the current state Ready reflector locked and ready to measure Compensation Absolute Tracker AT401 99 DRO Display modes 100 Measurement in progress Individual tolerance exceeded 90 2087 9 87 5501 3395 903 The Data Read Out DRO offers two different modes in compensation wizards to display the current reflector position Displays the absolute values of e Horizontal Angle H e Vertical Angle V e Distance D of the current reflector position in the sensor coordinate system Displays the relative values of e Horizontal Angle Delta AH e Vertical Angle Delta AV e Distance Delta AD of the current reflector position in relation to the next point to measure Ai The following symbols provide a graphical guidance in Delta HVD to find the nominal position Click on to toggle between the DRO display modes Absolute Tracker AT401 Compensation A Move the reflector up mwm Move the reflector down RM Move the reflector towards the Absolute Tracker AT4O1 Move the reflector away from the Absolute Tracker AT401 Move the reflector clockwise with reference to the sensor unit position for ADM Compensation only Move the reflector counter clockwise with reference to the lt J sensor unit position for ADM Compensation only Navigation The following controls are ava
119. to the measurements page Finish Click on the Finish button to generate the PDF report and finish the Angle Compensation process Click on the Cancel button to cancel the wizard and delete all measurements Ce Cancelling the process deletes all measured data Category Detail Information Information Passed Failed Name Comment Configuration User Windows User Login amp Tracker Pilot Login Tracker click on the link for further details IP Address Tracker Type Absolute Tracker AT401 Serial Number AT Controller 400 Server Version Active Compensation click on the link to display the active compensation parameters Active Reflector click on the link to display the details of the active reflector Inclination Sensor state Measurement Time Accuracy Level Temperature Pressure Humidity e Tolerance Used in Measurements Sketch Side View e Sketch Top View e Measurement Details Table Within the Report page of the Tracker Pilot tool tips are still displayed in sketch view and measurement details can be viewed as well Absolute Tracker AT401 Compensation Ce Use the Back button to navigate back to the measurements page i e to delete measurements or take additional measurements When returning to the Report page the report will be updated dynamically PDF report The generated PDF report is saved in the following default location on the application computer unless its saved into a personal folder ma
120. up Wizard This will install Tracker Pilot on your computer It is recommended that you close all other applications before continuing Click Next to continue or Cancel to exit Setup Press to continue or to terminate the installation Installation Absolute Tracker AT401 9 ie Setup Tracker Pilot Version 1 3 1 122 Select Start Menu Folder Where should Setup place the program s shortcuts Setup will create the program s shortcuts in the Following Start Menu folder To continue click Next IF you would like to select a different Folder click Browse Leica Tracker Pilot To select a different installation folder press and choose the location where the Tracker Pilot shall be installed It is recommended to install the Tracker Pilot into the proposed folder Click Next gt fto continue ie Setup Tracker Pilot Select Start Menu Folder Where should Setup place the program s shortcuts Setup will create the program s shortcuts in the following Start Menu folder To continue click Next If you would like to select a different folder click Browse Leica Tracker Pilot Press to confirm the proposed destination for the shortcut in the Windows Start Menu and to start the installation or press to change the destination ie Setup Tracker Pilot Version 1 3 1 122 Installing Please wait while Setup installs Tracker Pilot version 1 3 1 122 on your computer Extracting files C saum
121. ure the entered IP address for the application computer is different from the IP address of the AT Controller 400 Close the dialog by clicking DK two times Network connec To setup a network connection where the network adapter obtains its IP tion DHCP address from DHCP select the radio button Obtain IP address automati cally Internet Protocol TCP IP Properties pog General Alternate Configuration You can get IP settings assigned automatically if your network supports this capability Otherwise you need to ask your network administrator for the appropriate IP settings Obtain an IP address automatically Use the following IP address Obtain DNS server address automatically Use the following DNS server addresses Preferred DNS server Alternate DNS server S Close the dialog by clicking DK two times 4 2 2 Windows 7 Control Panel Click on the button to open the Windows Start menu m EI Getting Started Windows Media Center F Paint Documents Fc Pictures m Calculator Si Music Sticky Notes a Games QR Snipping Tool Computer Remote Desktop Connection Control Panel ae Magnifier Deen Change sett s 7 Solitaire Default Programs us Tracker Pilot i Help and Support gt All Programs Search programs and files E Launch the Control Panel Network Settings Absolute Tracker A
122. ve some reflectors to the trash bin first to be able to tio n import new ones i c Message details d Message short description a e Warning or error number The following controls are available tem Description O O Click OK to close the warning or error message pop up window The count down displays the remaining time before the window closes automatically 3 14 3 Exception Handling General User Interface In case of an exception which cannot be resolved by the user generate a Support File and contact your Leica Geosystems representative In case the Tracker Pilot crashes with an unhandled exception a message will pop up displaying the status of the software and the file name of the Support File that will be generated automatically To facilitate analyzing the problem please send this Support File to your Leica Geosystems representative xl OH Unhandled Exception A software problem has occured unexpectedly and TrackerPilot will be closed We apologize for the inconvenience this has caused you For your convenience a support file has been created under C Documents and Settings OPERAT OR Application Data TrackerPilot Support TrackerPilot_2010 04 15_14 29 29 sfile Please send this file to your local support service so that they can help you Refer to Create Support File on page 128 for details on creating Support Files Absolute Tracker AT401 55 4 Network Settings 4 1
123. vel Refer to Update System on page 130 for details on updating the Abso lute Tracker system The following controls are available Description Return to the main page of Tracker Pilot Click on In Outdoor Mode to access the Outdoor Mode settings Absolute Tracker AT401 User Interface L Inclination User Interface Outdoor Mode D Indoor OG Outdoor Standard lt 80m ci a Outdoor Long Range gt 80m i The following controls are available Click on the radio button Indoor to activate the Indoor mode The Indoor mode is the default mode e PowerLock mode user selectable e Accelerated Find Reflector search Click on the radio button Outdoor Standard lt 80 Outdoor Standard lt 80m m to activate the Outdoor Standard mode e PowerLock disabled e Reduced Find Reflector speed a Click on the radio button Outdoor Long Range gt 80 m to activate the Outdoor Long Range mode e PowerLock disabled e Reduced Find Reflector speed e ATR long range mode Return to the main page of Tracker Pilot The selected In Outdoor Mode is shown on the Tracker Pilot Status Bar and on the AT Controller 400 display mode Trracker Pilot AT Controller 400 un mE Outdoor Long Range gt 80m A compensation of the Absolute Tracker system can only be done in Indoor mode to achieve the highest possible accuracy of the system An impediment will be disp
124. within tolerance X Failed The ADM Compensation failed tolerance has been exceeded or measurement setup is insufficient 122 Absolute Tracker AT401 Compensation Report Compensation The Report shows detailed information about ADM Offset Compensation 28 w Passed Name Comment Configuration User Tracker IP Address Trecker Type Tracker Serial Server Version Compensation Reflector Inclination Sensor Measurement Time Accuracy Level Tempereture Pressure Humidity Results MPE Used Parameters Mar 25 2010 09 42 17 3 C RRR 1 5in OPERATOR as Advanced P2P Connection 192 168 0 1 Leica AT401 390206 3 6 70 Mar 23 2010 08 16 RRR 1 5in On 5000 ms 1 00 17 3 C 968 mBar 33 o 2 New Active Deviation Std Dev ADM Offset mm 7 174 73 000 80 174 Measurements In Id H deg V deg D mm i In 316 4967 89 0208 3205 456 2 In 137 1845 89 5978 3321 652 Measurements Out Sketch meest Eleng 1 Out 128 9211 89 0704 2869 968 2 Out 130 3532 89 9122 9248 844 Absolute Tracker AT401 123 The following actions can be taken Icon Description Save the Report as PDF file This button can be used to save the PDF Report in a personal folder In this case no copy of the report will be saved into the default location fe Print the Report ZC Use the Back button to navigate back to the measurements page Cli
125. x Activate WLAN To configure the AT Controller 400 to obtain an IP Address from DHCP over WLAN W LAN Configuration MAC 00 12 F3 07 53 CB d Activate WLAN SSID Leica AT401 Network Mode Get Address from DHCP Static IP Address IP Address IP Mask Gateway Address Encryption Method None WEP 64bit 40 24 exactly 5 chars Key WPA2 PSK Passphrase 8 63 chars Key On activating the settings the current connection will be closed and you have to reconnect Apply Required settings Activate WLAN Enabled Ticked User selectable SSID Default Leica AT401 Get Address from DHCP Three different encryption modes can be selected SSID Network Mode All input fields will be grayed out e None e WEP 64bit 40 24 e WPA2 PSK Passphrase The following controls are available Item None Absolute Tracker AT401 Network Settings Network Settings WEP Wired Equivalent Privacy using 64 key WEP 4O requires a key length of exactly 5 characters WEP 64bit 40 74 exactly 5 chars Key WPA PSK Passphrase 8 63 chars Key Wi Fi Protected Access 2 Pre shared key mode Passphrase allows a keylength of 8 to 63 char acters The encryption key can either be entered manually in case the WLAN access point has been configured in advance or automatically generated using the Generate button Generate This key is required to configure the WLAN
126. xxxxxx_MMM dd yyyy_hh mm ss Compensations tions e Max representing the 6 digit serial number of the Absolute Tracker AT401 e MMM dd yyyy_hh mm ss representing the date and time of the export Reflectors AT401_xxxxxx_MMM dd yyyy_hh mm ss Reflectors e XXXXXX representing the 6 digit serial number of the Absolute Tracker AT401 e MMM dd yyyy_hh mm ss representing the date and time of the export The exported files will be stored in the following location Windows XP C Documents and Settings Local User Applica tion Data Tracker Pilot Support Windows Vista C Users Local User AppData Roaming Tracker Pilot Support Windows 7 C Users Local User AppData Roaming Tracker Pilot Support Once the Support File has been saved a Windows Explorer will open up showing the content of the folder specified above Click on the following icon to export compensations and reflectors Export Compensations amp Description Reflectors Export the following items to the W Export Compensations amp Reflectors application computer e Compensations e Reflectors Export compensations and reflectors to two files The following screen appears Absolute Tracker AT401 Help Support Center Export Compensations amp Reflectors Exporting Compensations After the export has finished a Windows Explorer opens up displaying the exported files Be i Document s ard rd Eina OPE ALA TO Applic ation Data
127. yed decimals of the relevant dimension E Decrease displayed decimals of the relevant dimen a sion SS Apply changes to unit settings and return to the main WEE page of Tracker Pilot All unit and decimal settings only have an effect on the Tracker Pilot No changes are made on the AT Controller 400 by this function Changing the units and decimals will be stored persistently in a data file on the application computer 3 10 3 Viewing PDF Reports General 50 Generated PDF reports of checks and compensation are saved locally on the application computer Saved reports can be viewed with any PDF Reader i e Adobe Reader To view saved reports click on the link Reports Configuration Settings Ae Reports Clicking on the link opens a Windows Explorer displaying the folder where all PDF reports are saved Double click on the required PDF report to open it The file name of the PDF report consists of the serial number of the Abso lute Tracker date and the type check or compensation performed i e 390493 2010 04 14 11 30 Two Face Check pdf The Reports link will not be displayed In case no PDF reports are saved on the application computer Refer to PDF report on page 87 for details on the default file location of check PDF reports Refer to PDF report on page 111 for details on the default file location of compensation PDF Reports Absolute Tracker AT401 User Interface 3 11 Initial
Download Pdf Manuals
Related Search
Related Contents
取り扱い説明書はこちら ViewZ VZ-185LED-P Battery Charger Troubleshooting User Guide - kanepi Services Owner / Calibration Manual Alpine TME-M740BT User's Manual Untitled Enregistreur à carte mémoire AF-S DX Zoom-Nikkor 55-200mm f/4 ch Copyright © All rights reserved.
Failed to retrieve file