Home

EDGE PROTECTION SYSTEM STANDARD

image

Contents

1. Maximum load 1000 kg Console 46 0 63 130400 safetyrespect se VERTICAL BRACKET The Vertical Bracket is used on facades balconies or slab edges The vertical bracket allows mounting at the working level Alternative mounting position is outside the slab edge when there is a need for access to the slab edge The bracket has an integrated socket See information about attachments on page 4 SLAB EDGE BRACKET See information about attachments and mounting on page 4 10 B db safetyrespect se 46 0 63 130400 BEAM BRACKETS Beam brackets are available both for primary and secondary beams Beam brackets are available for different beam systems found in the market Make sure the brackets are correctly mounted in a vertical position and tightened properly Secondary Primary AN W Yj f Jd LA N NC 46 0 63 130400 safetyrespect se SAFETY 11 BARRIER BRACKETS BARRIER BRACKET WEDGE COUPLER Used with Barriers and Link Bars Mounted on 48 3 mm pipes and posts Make sure the brackets are tightened properly Used with Barriers and Adj Link Bars Mounted on 48 3 mm pipes and posts Make sure the brackets are tightened properly Mount the post in the 3r Socket and turn it at least half a turn to activate the post lock Ut pe gt GROUND SUPPORT PLATE Is used
2. SAFETY USER MANUAL EDGE PROTECTION SYSTEM STANDARD INSTRUCTIONS INACCORDANCE WITH EN 13374 D CONTENTS 3 Safety precautions 4 Attachments 5 Socketbase 6 Clamps 8 Platform Bracket 9 Console Bracket 10 Vertical Bracket 10 Slab Edge Bracket 11 Beam Brackets 12 Barrier Brackets 13 Post 13 Ground Support and Base Plate 14 Barriers 16 Adjustable Link Bars 17 Flex System 19 Standing Seam Bracket 20 Checklist for mounting CONTACT US Phone 46 0 63 130400 Fax 46 0 63 181319 E mail info safetyrespect se Web site www safetyrespect com Mail Deliveries SafetyRespect AB SafetyRespect AB Box 69 Jagarvallsvagen 19 SE 831 21 stersund Stadsdel Norr Sweden SE 831 32 Ostersund Sweden 2 safetyrespect se 46 0 63 130400 EJ SAFETY PRECAUTIONS Risks when mounting Falling Dropping of tools Dropping of components Crushing Injuries to eyes and ears Incorrect mounting Measures to minimise the risks Always use personal fall protection when carrying out mounting work When mounting or dismounting personal fall protection shall always be used if there is a risk of falling This also applies when working from a claw crane aerial platform etc We recommend using a painter connected to tools Cordon off the area below and around the place of mounting so that unauthorised people cannot be injured in case of dropping for instance tools or material Always use
3. clothing and protective equipment dedicated for the purpose Always check the products and equipment before use Do not use damaged material as it may influence the safety Use tools dedicated for mounting Do not combine products of different brands The fall protection is a system and should therefore not be used with other products that are not allowed by SafetyRespect The product responsibility applies only to SafetyRespect s products and approved solutions 46 0 63 130400 safetyrespect se SAFETY 3 ATTACHMENTS CONCRETE SCREW Drill holes that are 12 mm x 85 mm deep at least 120 mm from an edge Clear the hole from drilling residues Make sure the bracket is mounted so that the whole construction surface rests on the foundation Tighten screws but not too much Then the screw might come loose CONCRETE WEDGE ANCHOR Mounting should be done on f sufficiently hardened concrete only Drill a 20 mm hole that is at least 75 mm deep and 200 mm from the edge Clear the hole from drilling residues Mount wedge anchor M16 Then mount the bracket and screw the bolt to the wedge anchor 200mm MIN WOOD SCREW The wood should be of high quality and preferably cross glued in order for it not to crack Use wood screw for example WFD T 12 x 100 70 when mounting The screw should be mounted at least 100 mm from the nearest edge Tighten screws and make sure the bracket is mounted so that the whole construction surface rests on t
4. to protect sensitive surfaces or for building walk ways The Socket Base can be mounted at three different distances Nail or Screw the support where possible we A BARRIERS Place the Barrier on the Barrier bracket and lock it in a vertical position The Barriers shall always be mounted towards the working surface 14 SAFETY safetyrespect se 46 0 63 130400 The barrier s side with a logotype should face towards the posts Continue building with brackets posts and barrier The distance between the brackets should be a maximum of 2 4 metres Joint the barriers on the posts gt 4 End of barrier o anc PH The free end of the barrier ELA may not exceed 300 mm Each barrier must be supported by two posts 46 0 63 130400 safetyrespect se SAFETY 15 ADJUSTABLE LINK BARS Adjustable Link Bars are available in three different lengths and each of these is adjustable Mount Adjustable Link Bars onto the brackets of the posts and lock them in vertical position Adjust the link bar and tighten the stop screw properly BARRIER BRACKET 360 Used to create flexible corners and angels with Barriers and Link Bars 16 Budd safetyrespect se 46 0 63 130400 FLEX SYSTEM FLEX FACADE BRACKET I Can be mounted on steel concrete and wood Make sure the mounting meets the required extension load Adjust the po
5. he foundation 220mm 75mm Characteristic extension loads Concrete screw 12 x 75 36 0 kN Wedge anchor M16 31 8 kN Wood screw WFD 12 x 100 70 11 3 kN 4 SAFETY safetyrespect se 46 0 63 130400 SOCKETBASE Mount the Socketbase so that the whole construction surface rests on the foundation Tighten screws bolts so that the Socketbase is butt against the foundation MOUNTING WITH CONCRETE SCREW 12X75 See mounting instructions on page 4 MOUNTING WITH WEDGE ANCHOR M16 See mounting instructions on page 4 120mm MIN MOUNTING WITH WOOD SCREW 12X100 70 See mounting instructions on page 4 46 0 63 130400 safetyrespect se 3 clamps All clamp models should be mounted according to the following structure Check that the clamp is mounted transversely to the mounting surface see picture below Make certain to have as large a mounting surface as possible The clamp can be mounted both horizontally and vertically Protect sensitive surfaces that the clamp may damage when tightened Tighten so that the clamp is properly fastened in a stable manner NOT OK NOT OK CLAMP 550 Clamp 550 can be mounted either in horizontal or vertical postition and in staircases The Clamp can be mounted to the right or the left The gap can be adjusted from 20 mm up to 550 mm Make sure to tighten the clamp properly CLAMP 300 Clamp 300 can be mounted either in horizontal or vertical p
6. ostition in several situations The socket can be attached in four different places on the clamp The gap can be adjusted from 10 mm up to 300 mm Make sure to tighten the clamp properly 46 0 63 130400 safetyrespect se CONSOLE BRACKET SafetyRespect Console Bracket is used when edge protection must not interfere with the work surface or when the distance between the slab edge and edge protection requires adjustments The Console Bracket is used combined with the Socket Base See information about attachments and mounting on page 4 8 SAFETY safetyrespect se 46 0 63 130400 PLATFORM BRACKET Console Bracket 1 and Bracket Pin 2 are used together to create the product Platform Bracket This is intended to be used as a plateau for wooden beam 45 x 195 mm 3 to create a platform in shafts and openings MOUNTING Drill holes for bracket pin 220 depth 2 85 mm consider edge distance for drilling Clear the hole from drilling residues Install the Platform Bracket in the hole and do the same on the other side of the shaft or opening Cut the beam at the correct length to lock the Platform Bracket in both ends Warning SafetyRespect only takes responsibility for the Platform Bracket meets the requirements according to the prescribed use and not for timber or other details that may be included in Oblique ends the overall construction 4 8ppr 2 degrees
7. per depth and correct dimension and that the distances between the edges are according to the recommendations 3 The attachment parts are tightened against the foundation 5 and that there is no looseness 4 The posts are mounted and locked to the brackets 13 The posts should be turned at least half a turn 5 The barrier and link bars is correctly mounted on the 14 correct side of the posts 6 The lower edge of the barrier is close to the foundation 14 7 The barrier is locked with the railing lock 14 8 The joints between the barriers are correct 15 9 The free end of the barrier is a maximum of 300 mm 15 6 9 9 9 0 9 Contact SafetyRespect 46 0 63 130400 info safetyrespect se www safetyrespect com SAFETY 12 06 07
8. st socket to the working surface 1100 FLEX WORKING PLATFORM See user s manual for mounting instructions FLEX ROOF GABLE ATTACHMENT 1 Drill holes in the roof and mount the brackets 2 Adjust to the facade 3 Adjust the post socket to the working surface 46 0 63 130400 safetyrespect se SAFETY 17 FLEX EAVE BRACKET Please see the separate user s manual for more information 60 A E and mounting instructions O Say 18 STANDING SEAM BRACKET Standing Seam Brackets are used on sheet metal roofing with double lock standing seam The roof must be in good condition and the sheets well anchored to the underlay Mount the bracket over the standing seam allowing the seam locks to grip under the seam Tighten the bolts The bracket can be adjusted to four positions for roof pitches from 5 40 NOTE The bracket may only be subjected to forces directed parallel to the sheet metal seam 46 0 63 130400 safetyrespect se SAFETY 19 CHECKLIST FOR MOUNTING Carry out a careful inspection of your mounting to make certain that it has been done in accordance with the instructions If you have any questions please contact SafetyRespect Please use the checklist below for inspection Checklist for mounting of fall muc 1 The included components have been checked to ensure 3 that there is no damages 2 Holes for bolts wedge anchors have been drilled to the 4 pro