Using HyperTerminal with Agilent General Purpose

image

Contents

1. New Connectio Open Save Save As Whew ET m atates of Amernca fi Phone number PSR SRV AES UN A Connect using com Configure E ae ee ee eee ee Se ee se Sao eat coe ana alea tat Alt F4 Page 3 temp Properties ki ConnectTo settings Function arrow and ctrl keys act as Co Windows keys Emulation Auto detect Backscroll buffer lines FOL hemma sewa Beep three times when connecting or disconnechhg ASCII Setup Caneel temp Properties Conr iT T abh mnn ASCII Setup F ASCII Sending M Send lineerds with line feeds I Echo typed characters locally Line delay lo milliseconds Character delay jo milliseconds ASCII Receiving Append line feeds to incoming line ends T Force incoming data to 7 bit ASCII MW Wrap lines that exceed terminal Page 4 Le H gt eee AA D Click on ASCII Setup E Select Send line ends with line feeds and Select Echo typed character locally F Click on OK G Click on OK 8 Type in IDN to make sure the instrument returns the ID string as follows Type in IDN And then press the Enter button on the main keyboard not the number pad temp HyperTerminal File Edit TDN View Call Transfer Help AGILENT TECHNOLOGIES 34970A 0 11 1 2 Typical returned ID string Storing Returned Data Readings into a Text File Returned data
2. Using HyperTerminal with Agilent General Purpose Instruments Windows HyperTerminal can be used to program most General Purpose Instruments not the 531xx series counters using the RS 232 Serial Bus Instrument and HyperTerminal Setup Procedure In order to use the instrument with RS 232 the correct cable must be used It is a common mistake that any 9 pin RS 232 cable can be used This is not true Most Agilent instruments use the Null modem cable that is shipped with the instrument If unsure about the cable check the connections using an ohmmeter to the connections shown on page 6 in this document or in the instrument s User s manual 2 Setup the instrument to the factory default RS 232 settings Refer to the instrument User s manual for the settings The settings for some typical instruments are as follows Agilent 34970A Data Acquisition Switch Unit Baud Rate 57600 selectable Data bits 8 selectable Parity None selectable Start bits 1 fixed Stop bits 1 fixed Flow control XON XOFF Agilent 34401A Digital Multimeter Baud Rate 9600 selectable Data bits 8 selectable Parity None selectable Start bits 1 fixed Stop bits 2 fixed Flow control DTR DSR fixed Agilent 33120A Function Generator Arbitrary Waveform Generator Baud Rate 9600 selectable Data bits 8 selectable use this setting to download arbitrary waveforms Parity None selectable use this setting to download arbitrary
3. also stored into the test file Typical RS 232 Cable for General Purpose Instruments The following shows the cable used for most of the Agilent General Purpose Instruments like the 33120A 33250A 34401A and 34970A These instruments use a cable that can be ordered from Agilent s Parts Ordering department using part number RS232 61601 For other instruments check in the user s manual for the part number and connections gi RS 232 Cable Ea Computer Port Instrument Port DCD M e DCD RX 2 2 RX a a a aa DTR 4 4 DTR DSR 6 6 DSR wel g Om O es CTS 8 8 CTS RI Qe 9 RI DB9 DB9 DB9 DB9 Male Female Female Male Page 6
4. from an instrument can be stored into a text file using HyperTerminal For example the FETCh command used by the 34970A and other instruments returns the readings from instrument memory During the time the data is placed into the HyperTerminal window it can automatically be stored into a text file The following procedure shows how to do that Setup the HyperTerminal to transfer the data to a file as follows A Click on Transfer B Click on Capture Text temp ESE File Edt View Cal BREWER alel als f Send Receive Fig Capture Text Send Text File IDN AGILENT TECHN Capture te Printer ge C Select a Folder and File Name Capture Text Folder Cw INNT SProtiles pre D Click on Start File Browse Cancel Page 5 E Type in the FETCh command or any other command that is annronriate for vonr instrument temp HyperTerminal iofs File Edt View Call Transfer Help EIE IDN AWLENT TECHNOLOGIES 34970A 0 11 1 2 FETCH 3 12403000 E 04 4 14096300E 0 2 1 83036140E 02 72 22421790E 02 72 47799700E 0 zZ 3 60031000 E 04 2 6532 96180E 02 72 0775381 20E 0 2 05611580E 0z2 2 02953330E 0 Z 1 995370868240 E 1 929586895700 E 0 2 1 92068241 50E 02 1 91639360E 02 1 910725340E 0 Z 1 91548820E 0zZ 3 99010170E 02 2 2 6493130E 0z 2 14490330E 0z 2 116774 60E 0 Z The returned readings are displayed and
5. waveforms Start bits 1 fixed Stop bits 2 fixed Flow control DTR DSR fixed Agilent 33250A Function Generator Arbitrary Waveform Generator Baud Rate 57600 selectable Data bits 8 selectable use this setting to download arbitrary waveforms Parity None selectable use this setting to download arbitrary waveforms Start bits 1 fixed Stop bits 1 fixed Flow control DTR DSR use any flow control except XON XOFF to download arbitrary waveforms For other Agilent instruments not listed here refer to the instrument s User s Manual Page 3 Select HyperTerminal use the instructions for your operating system to select it 4 After HyperTerminal is enabled select the communication with the instrument as follows A Enter a connection name B Click on OK 5 Select the COM port as follows A Select the port COMI COM etc B Click on OK Page 2 6 Set the COM port parameters The following assumes that COM port is used and HyperTerminal is set to the 34970A s default configuration COM1 Properties Ed Port Settings A Select the a rv ei ee ea a Bn De J parameters Bits per second Data bits Parity a B Click on OK Stop bits Flow control 7 Setup the HyperTerminal as follows A Click on File C Click on Settings tab temp Froperties B Click on Connect To Settings Properties tomp HyperTerminal gem Edit