Home

NX-1348E User Manual Rev A

image

Contents

1. 2 NX1348E Icon Keypad NX 1348E ICON KEYPAD DIAGRAM For further details please refer to page 13 is on SERVICE icon is on er vor HERE to indicate a trouble disarmed flashes to condition with your indicate a previous alarm system ZONE icons numbers are on steady to indicate bypass slow flash for zone fault rapid flash for service condition INSTANT icon is on when there is no entry exit delay POWER Light is on when AC power is present flashes to indicate a low battery condition READY Light is on when the system is ready to arm flashes if ready to force arm ex FIRE Light is on to e indicate fire alarm flashes to indicate a EMERGENCY trouble condition with ACTIVATION KEYS your fire system bypass e Cancel 5 FUNCTION KEYS perform various 7 functions NUMERIC CODE ENTRY KEYS NOTE Some of the features described above may or may not be available for your system Check with your installation company to find out how your system is programmed SECURITY SYSTEM NOTES Installing Service Company For Service Call Central Station Duress Code This system isQ isnotQ partitioned EMERGENCY ACTIVATION KEYS check if enabled Q Fire U Auxiliary Emergency Police PROGRAMMED FUNCTIONS Abort Delay Cancel Alarm Forced Arming O Auto Bypass
2. DISARMING THE SYSTEM ette etes en ii dace CANCEL ABORT FEATURE BYPASSING ZONES itas ect Hi i EH e eee oe aaa GROUP BYPASS i 18 UNBYPASSIN Gov XY eee 18 TURNING THE DOOR CHIME ON AND OFF iii 18 CHANGING USER CODES wiswccsscesscosccshectstvscontecesctcecssscvadencsstsssetocedsnvavectsebesscentatedsnenscedseveeseistes 19 ASSIGNING USER CODE AUTHORITY 5 19 OTHER 21 SETTING THE KEYPAD TONE rre test rie 21 CHANGE PARTITION OPTIONAL i 21 VIEW ALARM MEMORY a TEST FUNCTION OPTIONAL ias 22 RESET RUNCHON ES IE IO IE 22 SET SYSTEM aia 22 SETTING THE SYSTEM CLOCK aacda 23 SETTING THE KEYPAD LIGHTING iiini nieee REE E E 23 SERVICE MENU 5 neaten oser eones saanane io oea Eae Eora Eo eo EE SESE E nas 23 KEYPAD CONTROL TONES BEEPS 25 EMERGENCY EVACUATION PLANS 25 NX1348E Icon Keypad Page 9 GLOSSARY OF TERMS An option that allows a delay in reporting to the central station Authority Level The level of access an individual has when using an alarm panel Central Station The location where alarm data is sent during an alarm report Chime Feature An option that allows the keypad to sound a ding dong whenever an entry exit
3. Step 1 Step 2 Press k 6 Master Arm Disarm Code Someone changing the authority of another person can only add or remove partition authorization for partitions to which they have access The ready icon will flash NX1348E Icon Keypad Page 19 Step 3 Step 4 Step 5 Step 6 Enter the 2 digit user number to be assigned authority The ready icon is constant and the instant icon will flash Icons illuminated indicate the authority levels assigned to this code An explanation of the icons is listed in the following table You may toggle turn on off the authority level by pressing the number for that authority level ICON AUTHORITY LEVELS IF ICON 8 IS OFF 1 Reserved Note Do not change if on Arm Only Arm Only After Closing Time Master Arm Disarm can program other codes Arm Disarm Bypass Zones Open Close Reporting If this icon is on this code is programmed as a function code INIA AJOJN Do not change Press to exit Press the key The ready icon is on constant and instant icon is on constant This moves you to the partition enable The user has access in partitions that are illuminated The illuminated numbers indicate each partition where the user has access To change any of the partitions where the user has access press numbers corresponding to areas where you want to give the user access or deny access Example
4. system by pressing either the STAY or EXIT key on the keypad control for ARMING only as programmed by the installing company User Code A four 4 or six 6 digit entry code used to arm or disarm the system ICON KEYPAD DISPLAY Ri in Power Armed Not Ready ALARM Service Instant Code Trouble FIRE Silenced Tamper 12 3 4 5 6 7 8 9 10111213141516 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 NX1348E Icon Keypad Page 11 EMERGENCY ACTIVATION KEYS 4 EJ EJ Fire Auxiliary Emergency Police NOTES You must hold these keys for 2 seconds to activate these functions Your system may not be programmed for these activation keys see page 1 You should press these keys only in an emergency situation that requires response by emergency personnel If your system is programmed for these functions the following reports can be sent Fire Key This key can activate the fire alarm when pressed for two seconds If your System is connected to a monitoring center an emergency report could be sent to that center Auxiliary Emergency Key This key can activate the auxiliary alarm when pressed for two seconds If your system is connected to a monitoring center an emergency report could be sent to that center Police Panic Hold Up Key This key can sound a local audible alarm when pressed for two seconds If your system is connected to a monit
5. SUPERVISION Press the 4 key and the zone icon s will illuminate showing which zone s has loss of supervision This only applies to wireless zones Press key to return to the 1 of 8 service icons RESERVED TELEPHONE LINE TROUBLE LINE CUT Press the 6 key The zone icon s will illuminate as they correspond to these service conditions 1 5 Reserved 6 Telephone Line Trouble Line Cut 7 Aux communication device failure The service icon will remain lit until the trouble clears and a user code is entered SEE NOTE AT END OF TABLE FAILURE TO COMMUNICATE This icon will illuminate when there is a failure to communicate between your system and the central station SEE NOTE AT END OF TABLE LOSS OF SYSTEM TIME This icon will illuminate when there has been a loss of power and your system clock needs to be reset Refer to page 23 SEE NOTE AT END OF TABLE EXIT Press the key to exit the Service Menu NOTE to Icons 6 7 8 This fault is global in nature and will affect all partitions of a multi partition system Page 24 NX1348E Icon Keypad KEYPAD CONTROL TONES BEEPS sounder is built into the keypad If programmed your system keypad may sound for any of the following reasons Beeps for all keypresses Sounds a continuous tone during the Entry delay time Pulses when a day zone is violated while the system is disarmed Pulses when a FIRE zone has a trouble
6. 2 Enter user code if required optional The bypass light flashes Step 3 Enter 1 or 2 digits indicating the zone you wish to bypass e press the 1 key for zone 1 press 1 2 for zone 12 Step 4 Press the BYPASS key again Step 5 The corresponding zone icon will illuminate indicating the zone has been bypassed Repeat steps 3 and 4 for any other zone s that need to be bypassed Step 6 Press the BYPASS key again or press the key to exit the Bypass Mode The bypass light will stop flashing upon exiting the Bypass Mode GROUP BYPASS By pressing the BYPASS key followed by the 0 key then the BYPASS key again all zones that are designated as group bypass zones will be bypassed Press the BYPASS key again or press the key to exit group bypassing UNBYPASSING To manually unbypass zones perform the bypassing procedure on a zone that is already bypassed The corresponding icon for that zone will go off when unbypassed NOTE All zones will automatically be unbypassed each time the system is disarmed TURNING THE DOOR CHIME ON AND OFF The door chime is turned on or off by pressing the CHIME key while the system is in the disarmed state If the chime is on the chime light will be illuminated If the chime is off the chime light will be off Each press of the CHIME key will toggle the chime feature on off and produce a momentary ding dong sound Page 18 NX1348E Icon Keypad ADDING AND CHANGING USER C
7. Change Partitions Group Bypass Auto Instant Chime A Quick Arm 3 Battery Test Communicator Test Re Exit Q Siren Test These features should not be enabled on UL listed systems ENTRY EXIT DELAY TIMES Exit Delay Time Secondary Exit Delay Time Entry Delay Time Secondary Entry Delay Time Page 4 NX1348E Icon Keypad ZONE DESCRIPTIONS 01 25 02 26 03 27 04 28 05 29 06 30 07 31 08 32 09 33 10 34 11 35 12 36 13 37 14 38 15 39 16 40 17 41 18 42 19 43 20 44 21 45 22 46 23 47 24 48 NX1348E Icon Keypad Page 5 INTRODUCTION This manual is furnished to help you understand your security system and become proficient in its operation All users of your security system should read and follow the instructions in this booklet and if possible practice on the keypad control while your professional installer is on site Failure to do so could result in the security System not working properly Please keep this booklet in an accessible location for the life of the security system If you do not understand any part of this manual you should notify your installing company The SECURITY CONTROL can be turned on ARMED and off DISARMED by entering a 4 or 6 digit code into the Keypad Control which is similar to a telephone keypad If your Security Contro
8. ODES Your system must be Disarmed to change user codes Step 1 Step 2 Step 3 Step 4 Step 5 Press k 5 The Enter Code icon will display Enter Master Arm Disarm Code For partitioned systems someone changing the code of another person must have access to all or more partitions than the user being changed The Ready icon will flash Enter the 2 digit user number Always enter 2 digits such as 0 3 for user 3 The instant icon will flash and zone icons will illuminate specifying the first digit of the user code When all icons are all illuminated code is blank when all icons are off 0 Use the A keys to view the next digit or enter new 4 or 6 digit user code While using the A and W keys you can change any digit by entering a new digit This will advance you to the next digit Step 6 Step 7 Step 8 To delete a user code enter sk sk k for a 4 digit code or k k k k 3k k a 6 digit code The ready icon will flash indicating you are back at Step 2 above If the code is rejected the sounder will beep 3 times If another user code needs to be programmed return to Step 4 Press the key while the ready icon is flashing to exit the User Code Programming Mode ASSIGNING USER CODE AUTHORITY LEVELS Assign authority levels to users by following the steps below Assign user codes before assigning authority levels
9. a floor plan of your home Show windows doors stairs and rooftops that can be used for escape Indicate each occupant s escape routes Always keep these routes free from obstruction Determine two means of escape from each room NX1348E Icon Keypad Page 25 One will be the normal exit from the building The other may be a window that opens easily An escape ladder may have to be located near the window if there is long drop to the ground below Set a meeting place outdoors for a headcount of the building occupants Practice escape procedures In a home sleep with bedroom door closed this will increase your escape time If you suspect fire test the door for heat If you think it is safe brace your shoulder against the door and open it cautiously Be ready to slam the door if smoke or heat rush in Practice escaping to the outdoors and meeting in an assigned spot Call the Fire Department from a neighbor s phone NOTE After the installation of your Security System has been completed notify your local Fire and Police Departments to give them your name and address for their records Early warning fire detection is best achieved by the installation of fire detection equipment in all rooms This equipment should be installed in accordance with the National Fire Protection Association s Standard 72 For additional information write the National Fire Protection Association Batterymarch Park Quincy MA 02269 The following are examples of
10. condition Beeps 3 times for trying to arm with the Not Ready icon off if Force Arming has not been selected Beeps for 1 second or emits a ding dong sound for the Chime feature Beeps during an exit delay beeps rapidly for the last 10 seconds of an exit delay and beeps 1 second at the end of the exit delay Pulses when the armed status changes and the AC power is off Pulses when the armed status changes and any zone s are bypassed Pulses when the armed status changes and a low battery is detected Pulses when the armed status changes and a Tamper condition is detected Beeps to indicate Telephone Line Cut if selected Pulses when or more the following conditions are detected Zone Box Tamper Low Battery AC Power Fail or Expander trouble Beeps 3 times once every minute for Sensor Zone Low Battery or Loss of Supervision Entering a code will silence the keypad for 12 hours Entering a valid code will silence the keypad sounder when it is pulsing The arm disarm state of your system will not change when entering a code to silence a pulsing keypad sounder Please contact your installer if a trouble condition exists EMERGENCY EVACUATION PLANS An emergency evacuation plan should be established for an actual fire alarm condition For example the following steps are recommended by the National Fire Protection Association and can be used as a guide in establishing an evacuation plan for your building Draw up
11. door is opened Codes Can be either User Codes relating to a person or Function Codes a toggle switch to turn specific functions on off NOTE A system may have either 99 four digit codes or 66 six digit codes but not a mixture of the two Duress Code An option that allows a special code to be sent to the central station that indicates the alarm system 15 being operated under duress Forced Arming An option that allows the system to be turned on ARMED with one or more zones open A system that is ready to be force armed will flash the ready Note Those zones that are not ready will not create an alarm Function Code A Function Code is either a four 4 or six 6 digit code that has been programmed by the installer to operate a device Group Bypass An option that allows the user to bypass multiple zones with a single operation Instant Delay An option that allows an instant alarm condition for Entry Exit doors or grants a delay to allow someone to enter exit the building without an alarm or before entering a user code to disarm Master Code A master arm disarm code that can program other user codes Partitioned System A system divided into multiple areas in which its own user or users control each area Perimeter The outer edge of the protected area Page 10 NX1348E Icon Keypad Quick Arm An option that allows you to turn on ARM the security
12. e system The armed icon and exit light will illuminate You may now leave the building NOTE The exit light will flash rapidly for the last 10 seconds of the exit delay as a warning to the user that the exit time is about to expire The user may wish to disarm and rearm the system if more time is needed NX1348E Icon Keypad Page 15 ARMING YOUR SYSTEM IN THE STAY MODE STAY is used when the user is inside the premise and wants protection around the perimeter Step 1 Step 2 Step 3 Step 4 Close all protected doors and windows Heady icon must be on or flashing when all protected zones and sensors are secure NOTE If any zones are bypassed a sensor in that zone can be violated without affecting the ready icon The security system will not arm if the not ready icon is on or flashing If the power icon is off you have no AC power Restore power if possible If not contact your installing company listed on page 1 of this booklet for service Enter your 4 or 6 digit user code If Auto Bypass is enabled all interior zones will be bypassed if you do not leave through a designated entry exit door If Auto Bypass is enabled omit Step 3 When Auto Instant is enabled if you do not leave through designated entry exit door the instant icon will illuminate indicating that the entry exit doors no longer have an entry delay If Auto Instant is enabled omit Step 4 Press the STAY key The stay light will i
13. evacuation plans A plan unique to your home or business should be drawn and memorized by each occupant KITCHEN BATH BEDROOM BEDROOM 4 y PU y A DINING ROOM DINO BEDROOM BEDROOM FIRST FLOOR vv SECOND FLOOR FRONT lt V BACK Page 26 NX1348E Icon Keypad SYSTEM NOTES NX1348E Icon Keypad Page 27 NX1348E SERIES USER S MANUAL NX1348EUA04 REVA May 2004
14. ion detector zones are bypassed TAMPER TROUBLE ICONS The tamper or trouble icon is on when a zone s is tampered or in trouble Press 2 and refer to the Service Menu section on page 23 of this manual for further instructions ZONE ICON The zone icons are off when everything is normal A zone icon will be if the zone has been bypassed If a zone icon is flashing that zone is in alarm or has been faulted If zone icon is flashing rapidly it means that the zone is in a trouble condition Trouble conditions are Tamper Hardware Low Battery Loss of Supervision A combination of Alarm Fault and Tamper Trouble will produce a rapid flashing light for a short period of time followed by a slow flashing light Page 14 NX1348E Icon Keypad KEYPAD FUNCTIONS ARMING YOUR SYSTEM IN THE AWAY MODE AWAY used when the user is away from the premise and wants the interior protected Step 1 Step2 Close all protected doors and windows Ready icon will be on or flashing when all protected zones and sensors are secure NOTE If any zones are bypassed a sensor in that zone can be violated without affecting the ready icon The security system will not arm if the not ready icon is on or flashing If the power icon is off you have no AC power Restore power if possible If not contact your installing company listed on page 1 of this booklet for service Enter your 4 or 6 digit user code to arm th
15. l has been so programmed you may be able to turn on ARM your System by simply pressing the STAY or EXIT key The system must always be disarmed using a 4 or 6 digit code The LED keypad includes up to 60 icons and a built in electronic sounder These provide specific information relating to the status of the security system which is described in the booklet Understanding what the icons and sounds mean will help you easily operate your system Keep in mind the level of security you will obtain with this system relates specifically with two major factors 1 The quantity quality and placement of security devices attached to this system 2 The knowledge you have of the security system and how that knowledge is utilized in a weekly test of the complete system You should be aware of the following facts when preparing a safety security plan for your home business Your security system is an electronic device and is subject to failure or malfunction Do not rely on it as your single source of security Your system should be tested weekly Your system will not work without power Warning devices will need to be loud enough wired correctly and properly placed to provide notification of an alarm event Smoke and heat detectors may not detect heat and smoke in all situations Use qualified security professionals to install and maintain your security system Page 6 NX1348E Icon Keypad It may be possible to arm the security system witho
16. lluminate indicating that all interior zones are bypassed All interior devices will bypass automatically giving the user freedom of movement within the interior area The bypass light will illuminate if any zone s are bypassed If any zone s have been bypassed previously by the user the icon s corresponding to the bypassed zone s will illuminate alerting the user that a zone s may be unprotected and can be faulted without an alarm To toggle from a delayed entry mode to an Instant mode press the STAY key again The instant icon will illuminate indicating that the entry exit doors have no entry delay Page 16 NX1348E Icon Keypad USING THE QUICK ARM Optional see page 1 The Quick Arm feature may be used if it is enabled Quick Arm will allow the user to arm the security system in the AWAY mode by pressing the EXIT key or arm in the STAY mode by pressing the STAY key This feature is used for ARMING ONLY and will not disarm the security system This is ideal for a maid or baby sitter code etc CHANGING MODES WHILE SYSTEM IS ARMED Pressing the STAY key will turn on off toggle a delay on entry exit doors and turn on off toggle the instanticon Optional Press the BYPASS key at this time to turn on off toggle all designated interior zones Optional When pressing the EXIT key will start the exit delay enabling you to leave the building IMPORTANT The instant icon needs to be off a
17. o set this adjustment in a darkened room SERVICE MENU The service icon will be if the security system requires service If the service icon is on press 2 to determine the service condition If a zone s is tampered the tamper icon will flash and the zone icon s will be on If a zone s is troubled the trouble icon will flash and the zone icon s will be on If the service icon is flashing one or more zone icon s will illuminate indicating what Service s is required Press the A W to scroll between tamper trouble and other service conditions Call your service provider immediately for these problems The following table provides a list of what each icon means in a service condition NX1348E Icon Keypad Page 23 PROBLEM SYSTEM FAULT Press the 1 key The zone icon s that is illuminated corresponds to the system fault s below 1 Over Current Fault 5 Expander Low Battery 2 Siren Trouble 6 Expander Box Tamper 3 Box Tamper 7 Expander Trouble 4 Expander Power 8 Ground Fault Note Faults 1 amp 2 are global in nature and will affect all partitions of a multi partition system Press the key to return to the 1 of 8 service icons RESERVED ZONE LOW BATTERY Press the 3 key The zone icon s will illuminate showing which zone s has a low battery This only applies to wireless zones Press the key to return to the 1 of 8 service icons ZONE LOSS OF
18. oring center an emergency report could be transmitted to that center NOTE Some Panic Hold Up alarms are programmed to be silent at the protected site while reporting an alarm to the monitoring center Check with your installing company to determine how your security System will respond to the Panic Hold Up activation Page 12 NX1348E Icon Keypad UNDERSTANDING THE ICONS 8 LIGHTS ARMED ICON The armed icon is on when the system is armed The armed icon is off when it is disarmed The armed icon will flash when there has been an alarm during the previous arm cycle BYPASS LIGHT The bypass light is when any zone in this keypad s partition is bypassed The zone s that is bypassed will also be illuminated If the bypass light is off no zones are bypassed CANCEL LIGHT The cancel light will flash during an abort delay time If a code is entered followed by the CANCEL key while this light is flashing all abortable reports will stop the communication process Note The abort feature must be enabled Entering a code followed by the CANCEL key during or after an alarm report to the central station will cause the cancel light to come on It will stay on until the central station has received the cancel report Note The cancel feature must be enabled CHIME LIGHT The chime light is when the chime feature is off otherwise EXIT LIGHT The exit light is on during the exit delay Please note tha
19. ssed for 60 seconds VIEW ALARM MEMORY Step 1 Press 3 The zone s that created the last alarm will be displayed along with the alarm icon flashing on the keypad Step2 The ALARM MEMORY feature will flash those zones that created alarms and will display steady those zones that were bypassed during the last alarm NX1348E Icon Keypad Page 21 TEST FUNCTION Optional If programmed this function will perform a battery test communicator test and or a siren test Alarms and reports will not be sent unless a communicator test is performed at which time a test signal will be sent Step 1 Press 4 The test will be performed as programmed Step 2 If the siren test is performed enter a user code to silence the siren RESET FUNCTION This function is used to reset Smoke Detectors Zone Troubles and Zone Tampers Your system must be Disarmed to use the Reset function Step 1 Press 7 Resets have now been performed Step2 If the keypad begins beeping the reset did not execute properly Enter your code to silence the keypad Wait a few minutes and repeat step 2 to attempt another reset If the keypad still beeps after repeated attempts please contact your installer SET SYSTEM DATE Step 1 Press 9 6 Enter Code icon will display Step 2 Enter a Master Code The service icon will appear flashing Step3 Enter the Day of Week 1 Sunday 3 Tuesday 5 Thursday 7 Saturday 2 Monday 4 Wednesday 6 Frida
20. t the light will flash during the last 10 seconds of the exit delay as a warning that the time is running out The user may want to disarm the system if the exit light is flashing in order to prevent an alarm The user may then re arm the system and exit before the delay expires FIRE ICON A steady fire icon means a fire zone has been faulted A rapidly flashing fire icon means that a fire zone is in a trouble condition INSTANT ICON The instant icon is when there is no delay on your entry exit door s Any time the instant icon is on and the exit delay has expired the opening of an entry exit door will produce an immediate alarm The instant icon can be toggled on or off by pressing the Stay key while the system is armed When the instant icon is off the entry exit door s is delayed NX1348E Icon Keypad Page 13 LISTEN IN ICON Listen in icon is on when an NX 534E active in listen in mode POWER ICON The power icon is on if the primary power is on The power icon will flash if the system has a low battery condition READY NOT READY ICON The ready icon is on when the system is ready to arm and flashes if ready to force arm The not ready icon is on when the system is not ready to arm because of a zone s being faulted SILENCED ICON The silenced icon appears after a code has been entered to silence the siren but the zone has not been cleared STAY LIGHT The stay light is when all interior mot
21. t this time if you plan on re entering the building otherwise you will create an alarm You may restore an entry delay by pressing the STAY key again DISARMING THE SYSTEM When you enter the protected area through one of the designated Entry Exit doors the keypad control will sound a continuous tone for the duration of the entry delay time or until you enter a valid code The armed icon will go off and the tone will stop The security system is now DISARMED If a valid code is not entered before the end of the entry delay an alarm will occur NOTE If the armed icon is flashing during the entry delay the alarm system has been activated in your absence Leave the building immediately and call your alarm company and or the police from a safe location CANCEL ABORT FEATURE Optional see page 1 The cancel light will flash during an abort delay time If a code is entered followed by the CANCEL key while this light is flashing all abortable reports will stop the communication process Entering a code followed by the CANCEL key during or after an alarm report to the central station will cause the cancel light to come on It will stay on until the central station has received the cancel report NX1348E Icon Keypad Page 17 BYPASSING ZONES If you wish to bypass one or more zones this must be done while the system is in the disarmed state The following steps are used for bypassing zones Step 1 Press the BYPASS key Step
22. ut the backup battery connected Your periodic test should be done with AC Power removed to verify the battery is connected and adequately charged Care should be taken to plug in and restrain the AC Transformer after testing Please read the following information and instructions carefully before operating your security control system NX1348E Icon Keypad Page 7 TABLE OF CONTENTS GLOSSARY OF 10 ICON KEYPAD 11 EMERGENCY ACTIVATION KEYS UNDERSTANDING THE ICONS amp LIGHTS ARMED ICON 13 BYPASS LIGA Tia Aa 13 CANCEL LIGH Tesis aaa 13 CHIME EIGHT a 13 A 13 FIRE ICON iia inicia HO B perat RE Rr E ts 13 INSTANT ICON toco ttt er Ad 13 LISTENIN ICON la RR Ee has Ere et YER CORR 14 POWERICON a epe e ORE e 14 READY NOT READY ICON eter ttem 14 SILENGED IC ON TRL 14 STAY LIGAT eb ee cobi eb e RE Beet erts 14 TAMPER TROUBLE retinent ette tetris bored 14 ZONE1CON etti tere Rr eei RE E EASIER eR e qd de 14 KEYPAD FUNCTIONS 15 ARMING YOUR SYSTEM IN THE AWAY MODE i 15 ARMING YOUR SYSTEM IN THE STAY MODE i 16 USING THE QUICK ARM 17 CHANGING MODES WHILE SYSTEM IS ARMED ceret 17 Page 8 NX1348E Icon Keypad TABLE OF CONTENTS CONTINUED
23. y Step4 Enter the Month Code Must always be two 2 digits 01 January 05 May 09 September 02 February 06 June 10 October 03 March 07 July 11 2 November 04 April 08 August 12 December Step5 Enter the Day Code Must always be two 2 digits Example The 5 would be entered as 0 5 Step6 Enter the last two digits of the Year Code Example For 2007 enter 0 7 The ready icon will appear Page 22 NX1348E Icon Keypad SETTING THE SYSTEM CLOCK Step 1 Press 9 7 Enter Code icon will appear Step2 Enter a Master Code Then the service icon will begin to flash Step3 Enter the hour code which must be two 2 digits Note The clock is a 24 hour clock Refer to the following table Step4 Enter the minutes code which must be two 2 digits Then the ready icon will come on constant Example 7 minutes after would be entered 0 7 Time Hour Code Time Hour Code Time Hour Code 12 00 Midniaht 00 8 00 AM 08 4 00 PM 16 1 00 AM 01 9 00 AM 09 5 00 PM 17 2 00 AM 02 10 00 AM 10 6 00 PM 18 3 00 AM 03 11 00 AM 11 7 00 PM 19 4 00 AM 04 12 00 Noon 12 8 00 PM 20 5 00 AM 05 1 00 PM 13 9 00 PM 21 6 00 AM 06 2 00 PM 14 10 00 PM 22 7 00 AM 07 3 00 PM 15 11 00 PM 23 SETTING THE KEYPAD LIGHTING Step1 Press 9 1 Step2 Press the A W scroll keys to lighten or darken the illumination behind the buttons and the LCD display It is usually easier t
24. zone icon 2 is lit then the user is assigned access to partition 2 By pressing the 2 key the icon will go off denying access to partition 2 Refer to the following chart ICON PARTITIONS ASSIGNED Partition 1 Partition 2 Partition 3 Partition 4 Partition 5 Partition 6 Partition 7 Partition 8 INID A oo Po Page 20 NX1348E Icon Keypad Step 7 Step 8 When the partitions are assigned press the key This returns you to Step 2 previously mentioned At this point you may enter another user number to assign authority level Repeat Steps 3 7 until you have assigned authority levels to all user numbers Press the key to exit the Assigning Authority Level Program OTHER KEYPAD FUNCTIONS SETTING THE KEYPAD TONE Step 1 Step 2 Step 3 Press 0 Keypad is now in the Adjust Tone mode Pressing the A key will make the keypad sounder go to higher tones pressing the W key will make the keypad sounder go to lower tones When the desired tone is reached press the key to set this tone and exit from the Adjust Tone mode CHANGE PARTITION Optional Step 1 Press 1 Step2 a NUMBER key between 1 and 8 to change partitions momentarily Step3 If no other key is pressed it will go back to its standard partition in ten seconds Step4 If another key is pressed the system will remain in the new partition until no keys have been pre